    OWL Intuition mit Node-RED einlesen

    This topic has been deleted. Only users with topic management privileges can see it.
    • P
      pix last edited by

      Hallo,

      ich war gestern auf dem Homematic Usertreffen von der Vorfuehrung des Node-RED Adapters so angetan, dass ihn unbedingt sofort ausprobieren musste.

      Ein Node kann auf UDP horchen, das passt zum http://www.amazon.de/Network-Owl-Energiemonitor-Funkempf%C3%A4nger-Netzwerkanschluss/dp/B00BVC048O/ref=pd_sim_ce_3?ie=UTF8&refRID=1R8W6H4ZD3CXBSAZ6FYW Strommesser, denn ich in CCU.IO bereits mit einem Adapter von mastermind einegbunden habe.

      In Node RED ist das viel einfacher (die Electricity ID habe ich anonymisiert).

      Übersicht des Flows:
      261_bildschirmfoto_2015-04-19_um_13.04.41.png

      Zuerst wird der UDP Multicast auf IP 224.192.31.19 Port 22600 (immer gleich) eingelesen.
      261_bildschirmfoto_2015-04-19_um_13.08.43.jpg

      Dann mit dem switch node prüfen, ob ein Inhalt ankommt (kann auch weggelassen werden).
      261_bildschirmfoto_2015-04-19_um_13.10.26.jpg

      Danach kommt der function node. Ich habe erstmal nur 4 Ausgänge definiert (es kommen noch mehr, vor allem die wichtigen). Ausserdem lasse ich im Debug Node zur Kontrolle den Gesamten Broadcast anzeigen.

      <electricity id="44371900XXXX"><signal rssi="-73" lqi="60"><battery level="100%"><chan id="0"><curr units="w">32.00</curr><day units="wh">594.46</day></chan><chan id="1"><curr units="w">0.00</curr><day units="wh">0.00</day></chan><chan id="2"><curr units="w">0.00</curr><day units="wh">0.00</day></chan></battery></signal></electricity>
      

      Daraus ziehe ich im function Node mit Javascript die Werte (Output auf erstmal 4 setzen, 3 Werte werden eingelesen, einer gesetzt).

      var quelle = msg.payload;
      
      msg1 = {};
      //  "electricity id=" finden (15 Zeichen lang), 1 überspringen und danach die 12 Zeichen verwenden
      var elec_id_startpos = quelle.indexOf('electricity id=');
      var electricityid = quelle.substr(elec_id_startpos + 15 + 1, 12);
      msg1.payload = parseInt(electricityid); // Zahl oder String ist egal
      
      msg2 = {};
      //  "rssi=>" finden (5 Zeichen lang), 1 Zeichen "'" überspringen und danach die 3 Zeichen verwenden
      var rssi_startpos = quelle.indexOf('rssi=');
      var rssi = quelle.substr(rssi_startpos + 6, 3);
      rssi = parseInt(rssi); // in Zahl umwandeln
      msg2.payload = rssi;  // eigentlich negative Zahl
      
      //  "battery level=" finden (14 Zeichen lang), 1 Zeichen "'" überspringen und danach die 4 Zeichen verwenden
      msg3 = {};
      var battery_startpos = quelle.indexOf('battery level=');
      battery = quelle.substr(battery_startpos + 1 + 14, 4);
      battery = battery.replace('%',''); // Prozentzeichen entfernen
      battery = battery.replace("'",""); // ggf "'" entfernen
      battery = parseInt(battery); // in Zahl umwandeln
      msg3.payload = battery;
      
      msg4={};
      msg4.payload = "Wert4 noch nicht ausgelesen";
      
      return [msg1,msg2,msg3, msg4];
      

      Die Ausgänge werden wieder mit dem Debug verbunden für die schnelle Kontrolle (grüne Nodes debug) und schließlich in ioBroker gespielt (blaue nodes iobroker). Dazu den konfigurieren:
      261_bildschirmfoto_2015-04-19_um_13.17.36.jpg

      Jetzt finden sich die Werte unter den Node Red Objekten:
      261_bildschirmfoto_2015-04-19_um_13.18.58.png

      Jetzt könnte man sie noch im Javascript- und VIS-Adapter weiterverarbeiten. Wenn der Flow fertig ist, kann ich ihn exportieren und zur Verfügung stellen. Wollte nur erstmal anfangen, solange alles noch frisch ist.

      Gruß

      Pix

      1 Reply Last reply Reply Quote 0
      • Bluefox
        Bluefox last edited by

        Super. Genau das habe ich von User erwartet.

        Ich denke wir können dafür extra Forum aufmachen, weil ich auch noch die 2 Beispiele mit Stau und Wetter posten will.

        1 Reply Last reply Reply Quote 0
        • P
          pix last edited by

          Okay, dann warte ich noch mit dem Posten der anderen Lösungen. Hab auf der Heimfahrt noch ne Spritpreisgeschichte gemacht und für Hormoran ist auch was dabei 8-)

          Gruß

          Pix

          1 Reply Last reply Reply Quote 0
          • Homoran
            Homoran Global Moderator Administrators last edited by

            @pix:

            …. Hab auf der Heimfahrt noch ne Spritpreisgeschichte gemacht und für Hormoran ist auch was dabei 8-)

            Gruß

            Pix `

            mach mich nicht noch neugieriger!

            Bluefox' post hat sich doch erledigt, er hat es doch schon verschoben.

            Gruß

            Rainer

            1 Reply Last reply Reply Quote 0
            • derAuge
              derAuge last edited by

              @pix:

              Okay, dann warte ich noch mit dem Posten der anderen Lösungen. Hab auf der Heimfahrt noch ne Spritpreisgeschichte gemacht und für Hormoran ist auch was dabei 8-)

              Gruß

              Pix `

              Spritpreise?

              von Tankerkönig?

              Gruß

              derAuge

              1 Reply Last reply Reply Quote 0
              • P
                pix last edited by

                Hallo,
                @derAuge:

                Spritpreise?

                von Tankerkönig? `
                Ja, siehe http://forum.iobroker.org/viewtopic.php?f=32&t=614#p4245.

                Gruß

                Pix

                1 Reply Last reply Reply Quote 0
                • P
                  pix last edited by

                  Hallo,

                  auch hier nochmal eine vereinfachte Version aus JSON. Damit werden jetzt ID, RSSSI, Battery, Ch1 aktuell, Ch1 Tagessumme ausgelesen und in ioBroker gespeichert.

                  Flow:

                  [{"id":"aa6c7136.55939","type":"udp in","name":"Network OWL horchen","iface":"","port":"22600","ipv":"udp4","multicast":"true","group":"224.192.32.19","datatype":"utf8","x":101,"y":41,"z":"dd405887.22bfa8","wires":[["3fd15b2d.c02ea4"]]},{"id":"ff460116.00ba","type":"debug","name":"OWL Ausgabe (original XML)","active":true,"console":"false","complete":"payload","x":1258,"y":36,"z":"dd405887.22bfa8","wires":[]},{"id":"3fd15b2d.c02ea4","type":"switch","name":"Prüfen","property":"payload","rules":[{"t":"nnull"}],"checkall":"true","outputs":1,"x":274,"y":38,"z":"dd405887.22bfa8","wires":[["ff460116.00ba","195ca17.fe6a35f"]]},{"id":"6777bb3e.988844","type":"debug","name":"OWL Ausgabe RSSI","active":true,"console":"false","complete":"payload","x":1219,"y":205,"z":"dd405887.22bfa8","wires":[]},{"id":"70261218.8fd9ec","type":"debug","name":"OWL Ausgabe Battery","active":true,"console":"false","complete":"payload","x":1256,"y":270,"z":"dd405887.22bfa8","wires":[]},{"id":"a9aaff38.5655","type":"ioBroker out","name":"OWL ElectricityID","topic":"OWL_ElectricityID","ack":"true","autoCreate":"true","x":932,"y":161,"z":"dd405887.22bfa8","wires":[]},{"id":"2b2a4b54.d4d5b4","type":"ioBroker out","name":"OWL rssi","topic":"OWL_rssi","ack":"true","autoCreate":"true","x":913,"y":232,"z":"dd405887.22bfa8","wires":[]},{"id":"46a3583b.b95ca8","type":"ioBroker out","name":"OWL battery","topic":"OWL_Battery","ack":"true","autoCreate":"true","x":927,"y":305,"z":"dd405887.22bfa8","wires":[]},{"id":"f7ea8ab1.081578","type":"debug","name":"OWL Ausgabe Kanal 1 aktuell","active":true,"console":"false","complete":"payload","x":1282,"y":346,"z":"dd405887.22bfa8","wires":[]},{"id":"95faa45e.6a0558","type":"ioBroker out","name":"OWL Kanal 1 aktuell","topic":"OWL_Ch1_aktuell","ack":"true","autoCreate":"true","x":943,"y":381,"z":"dd405887.22bfa8","wires":[]},{"id":"a066ac1.f5f995","type":"debug","name":"OWL Ausgabe Kanal 1 Tag","active":true,"console":"false","complete":"payload","x":1273,"y":426,"z":"dd405887.22bfa8","wires":[]},{"id":"1417981a.ebe868","type":"ioBroker out","name":"OWL Kanal 1 Tag","topic":"OWL_Ch1_Tag","ack":"true","autoCreate":"true","x":939,"y":468,"z":"dd405887.22bfa8","wires":[]},{"id":"5c074cbb.a3f8b4","type":"function","name":"Electricity ID","func":"msg.payload = msg.payload.electricity.$.id;\nreturn msg;","outputs":1,"valid":true,"x":670,"y":121,"z":"dd405887.22bfa8","wires":[["1b2c3217.e4d3ce","a9aaff38.5655"]]},{"id":"ef0185c3.10fe78","type":"debug","name":"Ausgabe als JSON","active":true,"console":"false","complete":"payload","x":1223,"y":77,"z":"dd405887.22bfa8","wires":[]},{"id":"1b2c3217.e4d3ce","type":"debug","name":"Ausgabe Electricity ID","active":true,"console":"false","complete":"payload","x":1233,"y":127,"z":"dd405887.22bfa8","wires":[]},{"id":"195ca17.fe6a35f","type":"xml","name":"","attr":"$","chr":"_","x":443,"y":78,"z":"dd405887.22bfa8","wires":[["ef0185c3.10fe78","5c074cbb.a3f8b4","edc113a3.123ef","9d912fdb.626ed","2d3bdbe7.d2c424","ac4a3cbd.53b5c"]]},{"id":"edc113a3.123ef","type":"function","name":"RSSI","func":"msg.payload = parseInt(msg.payload.electricity.signal[0].$.rssi);\nreturn msg;","outputs":1,"valid":true,"x":657,"y":208,"z":"dd405887.22bfa8","wires":[["6777bb3e.988844","2b2a4b54.d4d5b4"]]},{"id":"9d912fdb.626ed","type":"function","name":"Battery","func":"msg.payload = parseInt((msg.payload.electricity.battery[0].$.level).slice(0, -1)); // Prizent weg und integer\nreturn msg;","outputs":1,"valid":true,"x":656,"y":276,"z":"dd405887.22bfa8","wires":[["70261218.8fd9ec","46a3583b.b95ca8"]]},{"id":"2d3bdbe7.d2c424","type":"function","name":"Ch1 aktuell","func":"msg.payload = parseFloat(msg.payload.electricity.chan[0].curr[0]._);\nreturn msg;","outputs":1,"valid":true,"x":658,"y":344,"z":"dd405887.22bfa8","wires":[["f7ea8ab1.081578","95faa45e.6a0558"]]},{"id":"ac4a3cbd.53b5c","type":"function","name":"Ch1 Tag","func":"msg.payload = parseFloat(msg.payload.electricity.chan[0].day[0]._);\nreturn msg;","outputs":1,"valid":true,"x":654,"y":420,"z":"dd405887.22bfa8","wires":[["a066ac1.f5f995","1417981a.ebe868"]]}]
                  

                  Gruß

                  Pix

                  1 Reply Last reply Reply Quote 0
                  • P
                    pix last edited by

                    Hallo zusammen,

                    hier noch eine vereinfachte Version mit Ausgabe in verbesserter Baumstruktur (vorbereitet für mehrere OWL-Geräte).
                    261_bildschirmfoto_2015-05-10_um_15.32.59.jpg

                    [{"id":"aa6c7136.55939","type":"udp in","name":"Network OWL horchen","iface":"","port":"22600","ipv":"udp4","multicast":"true","group":"224.192.32.19","datatype":"utf8","x":104,"y":35,"z":"dd405887.22bfa8","wires":[["3fd15b2d.c02ea4"]]},{"id":"ff460116.00ba","type":"debug","name":"OWL Ausgabe (original XML)","active":false,"console":"false","complete":"payload","x":410,"y":33,"z":"dd405887.22bfa8","wires":[]},{"id":"3fd15b2d.c02ea4","type":"switch","name":"Prüfen","property":"payload","rules":[{"t":"nnull"}],"checkall":"true","outputs":1,"x":173,"y":118,"z":"dd405887.22bfa8","wires":[["ff460116.00ba","fdce747e.023188"]]},{"id":"f54f19ff.0ab0e8","type":"function","name":"Daten extrahieren","func":"var topic_baum = 'node-red.0.owl.electricity.' + msg.payload.electricity.$.id;\n\nmsg1 = {};\nmsg1.payload = msg.payload.electricity.$.id; // device id\nmsg1.topic = topic_baum + '.id';\n\nmsg2 = {};\nmsg2.payload = msg.payload.electricity.signal[0].$.rssi;\nmsg2.topic = topic_baum + '.rssi';\n\nmsg3 = {};\nmsg3.payload = msg.payload.electricity.battery[0].$.level;\nmsg3.topic = topic_baum + '.battery';\n\nmsg4 = {};\nmsg4.payload = msg.payload.electricity.chan[0].curr[0]._;\nmsg4.topic = topic_baum + '.kanal1.aktuell';\n\nmsg5 = {};\nmsg5.payload = msg.payload.electricity.chan[0].day[0]._;\nmsg5.topic = topic_baum + '.kanal1.tag';\n\nmsg6 = {};\nmsg6.payload = msg.payload.electricity.chan[1].curr[0]._;\nmsg6.topic = topic_baum + '.kanal2.aktuell';\n\nmsg7 = {};\nmsg7.payload = msg.payload.electricity.chan[1].day[0]._;\nmsg7.topic = topic_baum + '.kanal2.tag';\n\nmsg8 = {};\nmsg8.payload = msg.payload.electricity.chan[2].curr[0]._;\nmsg8.topic = topic_baum + '.kanal3.aktuell';\n\nmsg9 = {};\nmsg9.payload = msg.payload.electricity.chan[2].day[0]._;\nmsg9.topic = topic_baum + '.kanal3.tag';\n\nmsg10 = {};\nmsg10.payload = msg.payload.electricity.signal[0].$.lqi;\nmsg10.topic = topic_baum + '.lqi';\n\nreturn [msg1,msg2,msg3,msg4,msg5,msg6,msg7,msg8,msg9, msg10];","outputs":"10","valid":true,"x":527,"y":214,"z":"dd405887.22bfa8","wires":[["22c22d1b.dd3dd2","7d2504bc.82dafc"],["22c22d1b.dd3dd2","7d2504bc.82dafc"],["22c22d1b.dd3dd2","7d2504bc.82dafc"],["22c22d1b.dd3dd2","7d2504bc.82dafc"],["22c22d1b.dd3dd2","7d2504bc.82dafc"],["22c22d1b.dd3dd2","7d2504bc.82dafc"],["22c22d1b.dd3dd2","7d2504bc.82dafc"],["22c22d1b.dd3dd2","7d2504bc.82dafc"],["22c22d1b.dd3dd2","7d2504bc.82dafc"],[]]},{"id":"22c22d1b.dd3dd2","type":"debug","name":"Kontrollausgabe nach Funktion","active":true,"console":"false","complete":"payload","x":901,"y":161,"z":"dd405887.22bfa8","wires":[]},{"id":"60cea4f6.9f315c","type":"debug","name":"Ausgabe nach XML Baustein","active":false,"console":"false","complete":"payload","x":542,"y":75,"z":"dd405887.22bfa8","wires":[]},{"id":"fdce747e.023188","type":"xml","name":"","attr":"$","chr":"_","x":322,"y":171,"z":"dd405887.22bfa8","wires":[["60cea4f6.9f315c","f54f19ff.0ab0e8"]]},{"id":"7d2504bc.82dafc","type":"ioBroker out","name":"ioBroker Ausgabe","topic":"","ack":"false","autoCreate":"false","x":860,"y":272,"z":"dd405887.22bfa8","wires":[]}]
                    

                    Gruß

                    Pix

                    1 Reply Last reply Reply Quote 0
                    • R
                      Ritschi last edited by

                      Hallo

                      Ich habe den OWL Adapter auch in ccu.io eingebunden gehabt.

                      Nun habe ich mich auch getraut auf ioBroker umzusteigen.

                      Das Problem ist, dass ich bei diesem Thread als Hobbybastler nur Bahnhof verstehe.

                      Gibt es für ioBroker nicht einen Adapter den man einfach zufügen kann?

                      Gibt es irgendwo eine Schritt für Schritt Anleitung wie man solche Sachen in ioBroker macht?

                      Danke & Gruss

                      Ritschi

                      1 Reply Last reply Reply Quote 0
                      • Homoran
                        Homoran Global Moderator Administrators last edited by

                        Hallo Ritschi und Willkommen im Forum.

                        Leider gibt es noch keinen OneWire-Adapter für ioBroker.

                        Der node-red Adapter kann in vielen Fällen aber anstelle eines Adapters genutzt werden.

                        So hat ruhr70 auch erst einen sehr komplexen Flow für die Fritzbox gebaut, bevor das in einem Adapter umgesetzt wurde.

                        Leider habe ich keine OneWire-Hardware und kann ansonsten nichts dazu sagen.

                        Gruß

                        Rainer

                        1 Reply Last reply Reply Quote 0
                        • P
                          pix last edited by

                          Hallo Ritschi,

                          der OWL-Stream kann mit dem UDP Node in Node-Red abgefangen werden.

                          Du importierst http://forum.iobroker.org/posting.php?mode=reply&f=32&t=606&sid=080f0385faa7151c41c0078447252f12#pr4943 in Node Red. Die nötigen Objekte in ioBroker werden automatisch erzeugt.Unter Objekte/nodered/ findest du dann die Daten.

                          @Rainer: OWL ist nicht gleich OneWire. Das ist http://theowl.com/index.php/energy-monitors/ac/network-owl/

                          Gruß

                          Pix

                          1 Reply Last reply Reply Quote 0
                          • Homoran
                            Homoran Global Moderator Administrators last edited by

                            @pix:

                            @Rainer: OWL ist nicht gleich OneWire. Das ist OWL `

                            Danke pix - hätte sogar ich wissen müssen.

                            und einen OWFS-Adapter gibt es wohl, allerdings in der Version 0.0.2!

                            Ist heut wohl nicht mein Tag

                            Gruß

                            Rainer

                            1 Reply Last reply Reply Quote 0
                            • R
                              Ritschi last edited by

                              Hi Pix

                              Super, danke. wusste nicht, dass das oben ein Code für Flow ist.

                              Habe nun importiert und die Daten werden auch angezeigt.
                              620_bildschirmfoto_2015-08-02_um_15.08.09.png

                              Nun müsste ich doch den Verbrauch P1-3 und Stromverbrauch aktuell und heute irgendwo sehen?

                              Gruss

                              Ritschi

                              1 Reply Last reply Reply Quote 0
                              • Homoran
                                Homoran Global Moderator Administrators last edited by

                                Hast du die Netzwerkdaten angepasst und rechts oben auf deploy geklickt?

                                Gruß

                                Rainer

                                1 Reply Last reply Reply Quote 0
                                • R
                                  Ritschi last edited by

                                  Ja, auf deploy habe ich geklickt, aber die Netzwerkdaten nicht angepasst.

                                  Was und wo muss denn alles angepasst werden?

                                  Habe folgende Error im Log:

                                  2 Aug 16:57:00 - [error] [function:Daten extrahieren] TypeError: Cannot read property '/r> of undefined
                                  

                                  Gruss

                                  Ritschi

                                  1 Reply Last reply Reply Quote 0
                                  • P
                                    pix last edited by

                                    Hallo Ritschi,

                                    @Ritschi:

                                    Nun müsste ich doch den Verbrauch P1-3 und Stromverbrauch aktuell und heute irgendwo sehen? `

                                    Die siehst du unter Objekte/node-red.0/owl/electricity

                                    Es kann etwas dauern (max 5min), bis die Übertragung vom Network OWL startet. Den Zyklus kann man nicht beeinflussen, node-red bleibt passiv und fängt nur die Daten ab.

                                    Falls nicht, check mal im Flow den blauen ioBroker Ausgabe Button. Der Punkt AutoCreate sollte auf create states if not exist stehen.

                                    Zu Kontrolle der Ausgabe kannst du bei den grünen Debug-Nodes rechts das kleine Viereck anklicken und damit die Ausgabe im Debug-Fenster ein/ausschalten.

                                    Probier mal aus.

                                    Gruß

                                    Pix

                                    1 Reply Last reply Reply Quote 0
                                    • Homoran
                                      Homoran Global Moderator Administrators last edited by

                                      Hallo pix,

                                      kannst du da etwas zu sagen?

                                      @Ritschi:

                                      aber die Netzwerkdaten nicht angepasst.

                                      Was und wo muss denn alles angepasst werden? `

                                      Gruß

                                      Rainer

                                      1 Reply Last reply Reply Quote 0
                                      • P
                                        pix last edited by

                                        Hallo Rainer,

                                        es muss nichts angepasst. Werden. Der Network OWL sendet im lokalen Netzwerk immer auf der gleichen Adresse.
                                        @pix:

                                        Zuerst wird der UDP Multicast auf IP 224.192.31.19 Port 22600 (immer gleich) eingelesen. `
                                        Es braucht keinen Login o.ä., die Daten kommen, ob man will oder nicht. 😄

                                        Gruß

                                        Pix

                                        1 Reply Last reply Reply Quote 0
                                        • R
                                          Ritschi last edited by

                                          @pix:

                                          Hallo Ritschi,

                                          @Ritschi:

                                          Nun müsste ich doch den Verbrauch P1-3 und Stromverbrauch aktuell und heute irgendwo sehen? `

                                          Die siehst du unter Objekte/node-red.0/owl/electricity

                                          Es kann etwas dauern (max 5min), bis die Übertragung vom Network OWL startet. Den Zyklus kann man nicht beeinflussen, node-red bleibt passiv und fängt nur die Daten ab.

                                          Falls nicht, check mal im Flow den blauen ioBroker Ausgabe Button. Der Punkt AutoCreate sollte auf create states if not exist stehen.

                                          Zu Kontrolle der Ausgabe kannst du bei den grünen Debug-Nodes rechts das kleine Viereck anklicken und damit die Ausgabe im Debug-Fenster ein/ausschalten.

                                          Probier mal aus.

                                          Gruß

                                          Pix `

                                          Hi Pix

                                          Super Sache, das Problem lag daran dass anstelle "create states if non exist" folgendes angewählt war "Ignore messages for non existing states"

                                          Als ich das geändert hatte, tauchte innerhalb von 5 Minunten der Ordner OWL mit dem Inhalt auf.

                                          Herzlichen Dank allen Helfern!

                                          Gruss

                                          Ritschi
                                          3428_ifttt_1.jpg
                                          3428_ifttt_2.jpg
                                          3428_ifttt_aus_iobroker.jpg

                                          1 Reply Last reply Reply Quote 0
                                          • R
                                            Ritschi last edited by

                                            So und nun schon die nächste Frage 😕

                                            Gibt es eine Möglichkeit die Verbräuche in eine CCU2 Variable zu schreiben?

                                            Zudem interessiert mich nur der Aktuelle Verbrauch aller Phasen und der Tagesverbrauch gesamt.

                                            Gibt es da eine einfache Möglichkeit diese auch auszulesen?

                                            Gruss

                                            Ritschi

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            998