      @Röstkartoffel said in Adapter "smartmeter":

      @digitalnaive sagte in Adapter "smartmeter":

      @Homoran said in Adapter "smartmeter":

      @RappiRN sagte in Adapter "smartmeter":

      (Data Request Interval) mal bitte 60 eintragen,

      @digitalnaive
      Hast du das gemacht?

      @RappiRN sagte in Adapter "smartmeter":

      zeig doch bitte nochmal einen Screenshot deiner Einstellungen.

      kannst du uns bitte aktuell halten

      Ja hab ich gemacht.

      f9a9f9f6-d4ca-4870-b797-a6bdba50b68f-image.png

      Als Data Protokoll hast du "SML (SmartMeterLanguage 1.0.3)" eingetragen, das ist aber falsch. Der richtige Eintrag muss "D0" lauten.
      Außerdem kann ich die unteren Daten auf dem Screenshot nicht sehen, was hast du da stehen?

      331b446a-ff2d-426a-8cbf-3842dd5b1b6a-image.png

      Mit den Settings bekomme ich folgende Log Debug Meldung:

      smartmeter.0	2019-02-19 09:24:49.639	warn	No or too long answer from Serial Device after last request.
      smartmeter.0	2019-02-19 09:24:49.639	debug	Error: No or too long answer from Serial Device after last request.
      smartmeter.0	2019-02-19 09:24:49.637	debug	MESSAGE TIMEOUT TRIGGERED
      smartmeter.0	2019-02-19 09:24:19.632	debug	SET MESSAGE TIMEOUT TIMER2: 30000
      smartmeter.0	2019-02-19 09:24:19.630	debug	DONE SEND 0
      smartmeter.0	2019-02-19 09:24:19.377	debug	DONE SEND 1
      smartmeter.0	2019-02-19 09:24:19.234	debug	TO SEND 1: //?!!
      smartmeter.0	2019-02-19 09:24:19.234	debug	CURRENT PROCESS STEP 1 IN GETNEXTMESSAGE
      smartmeter.0	2019-02-19 09:24:19.234	debug	TO SEND 2:
      smartmeter.0	2019-02-19 09:24:19.234	debug	CURRENT PROCESS STEP 0 IN GETNEXTMESSAGE
      smartmeter.0	2019-02-19 09:24:19.234	debug	INITIAL MESSAGES TO SEND: 2
      smartmeter.0	2019-02-19 09:24:19.231	debug	SERIALPORT RESET BAUDRATE TO 300
      smartmeter.0	2019-02-19 09:24:19.228	debug	SERIALPORT OPEN
      smartmeter.0	2019-02-19 09:24:19.223	debug	CREATE SERIALPORT: 300 7 1 even
      smartmeter.0	2019-02-19 09:23:19.219	debug	SCHEDULE NEXT RUN IN 60000s
      smartmeter.0	2019-02-19 09:23:19.219	debug	DELETE rest of data (0) because new Message start with a new Request Message
      smartmeter.0	2019-02-19 09:23:19.219	debug	CURRENT SIGNON MESSAGE COUNTER 1 OF 1
      smartmeter.0	2019-02-19 09:23:19.219	debug	SERIALPORT REMOVE LISTENERS
      smartmeter.0	2019-02-19 09:23:19.218	debug	SERIALPORT CLOSE
      smartmeter.0	2019-02-19 09:23:19.214	debug	CLEAR MESSAGE TIMEOUT TIMER
      smartmeter.0	2019-02-19 09:23:19.214	debug	STOP
      smartmeter.0	2019-02-19 09:23:19.214	debug	Transport Reset!! Restart = true
      smartmeter.0	2019-02-19 09:23:19.213	debug	Error: No or too long answer from Serial Device after last request.
      smartmeter.0	2019-02-19 09:23:19.213	warn	No or too long answer from Serial Device after last request.
      
      1 Reply Last reply Reply Quote 0
      • Röstkartoffel
        Röstkartoffel last edited by Röstkartoffel

        Kannst du bitte mal in der SignOnMessage anstelle von /?! nur das ? eintragen?

        Und kannst du uns mal deine Adapter Versionsnummer nennen?

        D 1 Reply Last reply Reply Quote 1
        • D
          digitalnaive @Röstkartoffel last edited by

          @Röstkartoffel said in Adapter "smartmeter":

          Kannst du bitte mal in der SignOnMessage anstelle von /?! nur das ? eintragen?

          Und kannst du uns mal deine Adapter Versionsnummer nennen?

          Es geht!!! Sorry für die Ausrufezeichen aber das war der entscheidende Tipp!!!!

          1 Reply Last reply Reply Quote 0
          • R
            RappiRN Most Active last edited by

            Du kannst ja dann noch mit den Zeiten probieren, wie oft und wie schnell du auslesen kannst.

            Wenn es dann zufriedenstellend funktioniert, stelle doch bitte nochmal einen Screenshot von deinen Einstellungen mit dem kompletten Namen deines Zählers rein, damit es für die Nachwelt erhalten bleibt! 👍

            Enrico

            1 Reply Last reply Reply Quote 0
            • F
              flubb last edited by

              Hallo zusammen,

              ich habe mir jetzt auch den Adapter installiert und einen selbstgebauten Lesekopf mit Bauteilen für unter 5€ angeschlossen (siehe hier).
              Der Lesekopf arbeitet tatsächlich einwandfrei nur hat mein Stromzähler (DZG DVS74) wohl leider einen Bug bei der Kodierung von manchen positiven Verbrauchswerten. D.h. teilweise wird meine SML-Nachricht einwandfrei empfangen, zwischendurch habe ich jedoch z.B. folgende Fehlermeldung:

              Error while parsing SML message: Error: Wrong TL-Field (7) for Unsigned!: Message: 1b1b1b1b010101017605e9128c02620062007263010176010102310b0a01445a470002829d5d72620164dc3845620263894a007605ea128c0262

              Den Hinweiß bzgl. dem Bug habe ich bei Volkszähler gefunden. Hier wird auch ein Workaround für den Bug beschrieben: Link zum Workaround

              Nun meine Frage:
              Habe ich denn eine Möglichkeit dieses Workaround auch bei Verwendung des iobroker-Adapters einzusetzen?

              DANKE,
              Grüße
              Markus

              1 Reply Last reply Reply Quote 0
              • wendy2702
                wendy2702 last edited by

                Ich bin auch gerade durch Zufall auf diese Logzeilen gestoßen:

                host.pi-iobroker	2019-02-20 15:39:09.433	error	instance system.adapter.smartmeter.0 terminated with code 0 (OK)
                host.pi-iobroker	2019-02-20 15:39:09.433	error	Caught by controller[0]: at process._tickCallback (internal/process/next_tick.js:104:9)
                host.pi-iobroker	2019-02-20 15:39:09.433	error	Caught by controller[0]: at _combinedTickCallback (internal/process/next_tick.js:73:7)
                host.pi-iobroker	2019-02-20 15:39:09.429	error	Caught by controller[0]: at process.nextTick (/opt/iobroker/node_modules/iobroker.smartmeter/node_modules/serialport/lib/serialport.js:206:31)
                host.pi-iobroker	2019-02-20 15:39:09.429	error	Caught by controller[0]: at SerialPort._error (/opt/iobroker/node_modules/iobroker.smartmeter/node_modules/serialport/lib/serialport.js:199:14)
                host.pi-iobroker	2019-02-20 15:39:09.429	error	Caught by controller[0]: at SerialPort.<anonymous> (/opt/iobroker/node_modules/iobroker.smartmeter/node_modules/smartmeter-obis/lib/transports/SerialResponseTransport.js:223:29)
                host.pi-iobroker	2019-02-20 15:39:09.427	error	Caught by controller[0]: TypeError: Cannot read property 'logger' of undefined
                smartmeter.0	2019-02-20 15:39:08.890	warn	ERROR CLOSING SERIALPORT
                smartmeter.0	2019-02-20 15:39:08.890	warn	ERROR CLOSING SERIALPORT
                smartmeter.0	2019-02-20 15:39:08.890	warn	Exception: TypeError: Cannot read property 'logger' of undefined
                smartmeter.0	2019-02-20 15:39:08.890	error	TypeError: Cannot read property 'logger' of undefined at SerialPort.<anonymous> (/opt/iobroker/node_modules/iobroker.smartmeter/node_modules/smartmeter-obis/lib/transports/SerialResponseTransport.
                smartmeter.0	2019-02-20 15:39:08.889	error	uncaught exception: Cannot read property 'logger' of undefined
                smartmeter.0	2019-02-20 15:39:08.886	warn	Error while parsing SML message: Error: Wrong TL-Field (7) for Unsigned!: Message: 1b1b1b1b010101017607000fc3bc620062007263010176010107000f032196940b0901454d4800006544b301016348c5007607000f0ab1c3bd62
                

                Mein Zähler ist der EMH ED300L

                Einstellungen:

                0ddac6bb-c7bd-40e1-bbe9-0468171e2ac3-image.png

                Jemand eine Idee oder gleiches Problem wie beim Post davor?

                1 Reply Last reply Reply Quote 0
                • B
                  backons last edited by

                  Hallo,

                  ich habe heute meinen Adapter von Weidmann Elektronik bekommen und angeschlossen.
                  Als Stromzähler habe ich einen MT175 und folgendes habe ich im Smartmeter eingestellt:

                  Bildschirmfoto 2019-02-20 um 20.44.12.png

                  wenn ich den Adapter starte kommt folgendes im LOG:

                  host.rock64	2019-02-20 20:41:12.062	info	Restart adapter system.adapter.smartmeter.0 because enabled
                  host.rock64	2019-02-20 20:41:12.062	error	instance system.adapter.smartmeter.0 terminated with code 1 ()
                  Caught	2019-02-20 20:41:12.061	error	by controller[0]: at Object.Module._extensions..js (module.js:664:10)
                  Caught	2019-02-20 20:41:12.061	error	by controller[0]: at Module._compile (module.js:653:30)
                  Caught	2019-02-20 20:41:12.061	error	by controller[0]: at Object.<anonymous> (/opt/iobroker/node_modules/serialport/lib/bindings/linux.js:2:36)
                  Caught	2019-02-20 20:41:12.061	error	by controller[0]: at bindings (/opt/iobroker/node_modules/serialport/node_modules/bindings/bindings.js:81:44)
                  Caught	2019-02-20 20:41:12.061	error	by controller[0]: at require (internal/module.js:11:18)
                  Caught	2019-02-20 20:41:12.061	error	by controller[0]: at Module.require (module.js:597:17)
                  Caught	2019-02-20 20:41:12.060	error	by controller[0]: at Function.Module._load (module.js:498:3)
                  Caught	2019-02-20 20:41:12.060	error	by controller[0]: at tryModuleLoad (module.js:506:12)
                  Caught	2019-02-20 20:41:12.060	error	by controller[0]: at Module.load (module.js:566:32)
                  Caught	2019-02-20 20:41:12.060	error	by controller[0]: at Object.Module._extensions..node (module.js:682:18)
                  Caught	2019-02-20 20:41:12.060	error	by controller[0]: Error: /opt/iobroker/node_modules/serialport/build/Release/serialport.node: wrong ELF class: ELFCLASS32
                  Caught	2019-02-20 20:41:12.060	error	by controller[0]: ^
                  Caught	2019-02-20 20:41:12.059	error	by controller[0]: throw e
                  Caught	2019-02-20 20:41:12.059	error	by controller[0]: /opt/iobroker/node_modules/serialport/node_modules/bindings/bindings.js:88
                  host.rock64	2019-02-20 20:41:10.699	info	instance system.adapter.smartmeter.0 started with pid 9496
                  

                  Kann mir jemand sagen was den Fehler auslöst ?

                  1 Reply Last reply Reply Quote 0
                  • porty
                    porty last edited by porty

                    @backons

                    warum hast du unter Datenprotokoll: D0 angegeben?
                    Der MT175 nutzt die SML (SmartMeterLanguage)
                    Dann ist schon mal die Hälfte der Settings weg.

                    Dann trägst du den USb Port ein. Am besten als "/dev/serial/by-id/id_bzw_port_des_Adapters"

                    1 Reply Last reply Reply Quote 0
                    • D
                      digitalnaive last edited by

                      Jetzt muss ich den Thread leider doch wieder aufgreifen. Aus dem nichts bekomme ich plötzlich keine Werte mehr von meinem Smartmeter. Und die Logfile wirft alt bekannte Probleme aus. Was kann denn dafür der Grund sein, dass ein vorher funktionierendes Setting plötzlich nicht mehr die gewünschten Daten liefert?

                      smartmeter.0	2019-03-13 09:22:12.929	debug	SCHEDULE NEXT RUN IN 30000s
                      smartmeter.0	2019-03-13 09:22:12.929	debug	DELETE rest of data (0) because new Message start with a new Request Message
                      smartmeter.0	2019-03-13 09:22:12.929	debug	CURRENT SIGNON MESSAGE COUNTER 1 OF 1
                      smartmeter.0	2019-03-13 09:22:12.929	debug	SERIALPORT REMOVE LISTENERS
                      smartmeter.0	2019-03-13 09:22:12.929	debug	SERIALPORT CLOSE
                      smartmeter.0	2019-03-13 09:22:12.929	debug	CLEAR MESSAGE TIMEOUT TIMER
                      smartmeter.0	2019-03-13 09:22:12.928	debug	STOP
                      smartmeter.0	2019-03-13 09:22:12.928	debug	Transport Reset!! Restart = true
                      smartmeter.0	2019-03-13 09:22:12.928	debug	Error: No or too long answer from Serial Device after last request.
                      smartmeter.0	2019-03-13 09:22:12.928	warn	No or too long answer from Serial Device after last request.
                      smartmeter.0	2019-03-13 09:22:12.928	debug	Error: No or too long answer from Serial Device after last request.
                      smartmeter.0	2019-03-13 09:22:12.927	debug	MESSAGE TIMEOUT TRIGGERED
                      smartmeter.0	2019-03-13 09:21:42.916	debug	SET MESSAGE TIMEOUT TIMER2: 30000
                      smartmeter.0	2019-03-13 09:21:42.915	debug	DONE SEND 0
                      smartmeter.0	2019-03-13 09:21:42.664	debug	DONE SEND 1
                      smartmeter.0	2019-03-13 09:21:42.658	debug	TO SEND 1: /?!
                      smartmeter.0	2019-03-13 09:21:42.657	debug	CURRENT PROCESS STEP 1 IN GETNEXTMESSAGE
                      smartmeter.0	2019-03-13 09:21:42.657	debug	TO SEND 2:
                      smartmeter.0	2019-03-13 09:21:42.656	debug	CURRENT PROCESS STEP 0 IN GETNEXTMESSAGE
                      smartmeter.0	2019-03-13 09:21:42.655	debug	INITIAL MESSAGES TO SEND: 2
                      smartmeter.0	2019-03-13 09:21:42.652	debug	SERIALPORT RESET BAUDRATE TO 300
                      smartmeter.0	2019-03-13 09:21:42.644	debug	SERIALPORT OPEN
                      smartmeter.0	2019-03-13 09:21:42.624	debug	CREATE SERIALPORT: 300 7 1 even
                      smartmeter.0	2019-03-13 09:21:42.619	debug	SmartmeterObis options: {"debug":2,"protocol":"D0Protocol","transport":"SerialRequestResponseTransport","requestInterval":"30","transportSerialPort":"/dev/ttyUSB0","transportSerialB
                      

                      8c2afe3e-0281-4b9b-9c41-8f98935f6183-image.png

                      1 Reply Last reply Reply Quote 0
                      • wendy2702
                        wendy2702 last edited by wendy2702

                        Pauschal würde ich sagen du hast das wieder geändert....

                        @digitalnaive sagte in Adapter "smartmeter":

                        @Röstkartoffel said in Adapter "smartmeter":

                        Kannst du bitte mal in der SignOnMessage anstelle von /?! nur das ? eintragen?

                        Und kannst du uns mal deine Adapter Versionsnummer nennen?

                        Es geht!!! Sorry für die Ausrufezeichen aber das war der entscheidende Tipp!!!!

                        zumindest laut deinem Logfile:

                        @digitalnaive sagte in Adapter "smartmeter":

                        smartmeter.0 2019-03-13 09:21:42.658 debug TO SEND 1: /?!

                        D 1 Reply Last reply Reply Quote 0
                        • D
                          digitalnaive @wendy2702 last edited by

                          @wendy2702 said in Adapter "smartmeter":

                          Pauschal würde ich sagen du hast das wieder geändert....

                          @digitalnaive sagte in Adapter "smartmeter":

                          @Röstkartoffel said in Adapter "smartmeter":

                          Kannst du bitte mal in der SignOnMessage anstelle von /?! nur das ? eintragen?

                          Und kannst du uns mal deine Adapter Versionsnummer nennen?

                          Es geht!!! Sorry für die Ausrufezeichen aber das war der entscheidende Tipp!!!!

                          zumindest laut deinem Logfile:

                          @digitalnaive sagte in Adapter "smartmeter":

                          smartmeter.0 2019-03-13 09:21:42.658 debug TO SEND 1: /?!

                          Siehe meinen Screenshot. Das ist der Screenshot von heute. Ich habe diese Config nicht eine Sekunde angefasst. Mir ist diese Zeile auch schon aufgefallen. Aber ich habe hier immernoch nur ein Fragezeichen drinnen stehen.

                          1 Reply Last reply Reply Quote 0
                          • wendy2702
                            wendy2702 last edited by wendy2702

                            Wurden sonst irgendwelche Upgrades am PI gemacht?

                            Den PI mal neu gestartet?

                            D 1 Reply Last reply Reply Quote 0
                            • Röstkartoffel
                              Röstkartoffel last edited by

                              Das / und das ! trägt der Adapter selbstständig ein, so dass im Log das dann so steht: /?!

                              1 Reply Last reply Reply Quote 0
                              • D
                                digitalnaive @wendy2702 last edited by digitalnaive

                                @wendy2702 said in Adapter "smartmeter":

                                Wurden sonst irgendwelche Upgrades am PI gemacht?

                                Den PI mal neu gestartet?

                                Es gab ein Upgrade von JavaScript, Vis und Mobile. Beeinflusst JavaScript die Veränderung evtl?

                                Update javascript from @3.6.5 to @4.1.12
                                NPM version: 6.4.1

                                Homoran 1 Reply Last reply Reply Quote 0
                                • Homoran
                                  Homoran Global Moderator Administrators @digitalnaive last edited by

                                  @digitalnaive

                                  @wendy2702 sagte in Adapter "smartmeter":

                                  Wurden sonst irgendwelche Upgrades am PI gemacht?

                                  Wendy meint den pi selber (denke ich), nicht iobroker

                                  @digitalnaive sagte in Adapter "smartmeter":

                                  Beeinflusst JavaScript die Veränderung evtl?

                                  nein!

                                  @wendy2702 sagte in Adapter "smartmeter":

                                  Den PI mal neu gestartet?

                                  Das hast du aber inzwischen gemacht?

                                  D 1 Reply Last reply Reply Quote 0
                                  • D
                                    digitalnaive @Homoran last edited by digitalnaive

                                    @Homoran Ja, hab ihn sicherheitshalber jetzt ein zweites mal restartet.

                                    Folgende Meldung:

                                    smartmeter.0	2019-03-13 09:54:07.177	debug	SCHEDULE NEXT RUN IN 30000s
                                    smartmeter.0	2019-03-13 09:54:07.177	debug	DELETE rest of data (0) because new Message start with a new Request Message
                                    smartmeter.0	2019-03-13 09:54:07.176	debug	CURRENT SIGNON MESSAGE COUNTER 1 OF 1
                                    smartmeter.0	2019-03-13 09:54:07.176	debug	ERROR CLOSING SERIALPORT: Error: Port is not open
                                    smartmeter.0	2019-03-13 09:54:07.176	debug	TO SEND 1: /?!
                                    smartmeter.0	2019-03-13 09:54:07.176	debug	CURRENT PROCESS STEP 1 IN GETNEXTMESSAGE
                                    smartmeter.0	2019-03-13 09:54:07.176	debug	TO SEND 2:
                                    smartmeter.0	2019-03-13 09:54:07.176	debug	CURRENT PROCESS STEP 0 IN GETNEXTMESSAGE
                                    smartmeter.0	2019-03-13 09:54:07.176	debug	INITIAL MESSAGES TO SEND: 2
                                    smartmeter.0	2019-03-13 09:54:07.176	debug	CLEAR MESSAGE TIMEOUT TIMER
                                    smartmeter.0	2019-03-13 09:54:07.176	debug	STOP
                                    smartmeter.0	2019-03-13 09:54:07.176	debug	Transport Reset!! Restart = true
                                    smartmeter.0	2019-03-13 09:54:07.176	debug	Error: Error on Baudrate changeover: Error: Port is not open
                                    smartmeter.0	2019-03-13 09:54:07.176	warn	Error on Baudrate changeover: Error: Port is not open
                                    

                                    Ergänzung. Mir wirft ls l /dev/ttyUSB* folgendes aus?! Auch daran habe ich nichts verändert. Heißt das auf gut deutsch, dass mein USB Gerät nicht mehr "eingehängt" ist?

                                    digitalnaive@asrock:~$ ls -l /dev/ttyUSB*
                                    ls: cannot access '/dev/ttyUSB*': No such file or directory
                                    
                                    1 Reply Last reply Reply Quote 0
                                    • wendy2702
                                      wendy2702 last edited by wendy2702

                                      Was kommt denn hier:

                                      sudo dmesg | grep tty
                                      

                                      Um festzustellen ob es etwas mit den Updates zu tun hat, könntest du mal downgrades machen... einem nach dem anderen und dazwischen immer schauen ob sich etwas geändert hat.

                                      Node/NPM hast du nicht zufällig auch upgedated?

                                      D 1 Reply Last reply Reply Quote 0
                                      • D
                                        digitalnaive @wendy2702 last edited by

                                        @wendy2702

                                        digitalnaive@asrock:/dev$ sudo dmesg | grep tty
                                        [    0.000000] console [tty0] enabled
                                        

                                        Nein da hab ich keine Updates gemacht. Ich hatte lediglich eine zusätzliche USB Festplatte angeschlossen. Das dürfte doch aber die bestehende Konfiguration nicht beeinträchtigen. Oder denke ich da zu naiv?

                                        1 Reply Last reply Reply Quote 0
                                        • wendy2702
                                          wendy2702 last edited by

                                          Pauschal würde ich sagen das deine USB Device nicht erkannt werden.

                                          Mal alle USB Device abstecken.

                                          Dann

                                          dmesg
                                          

                                          Lesekopf anstecken und erneut dmesg, ist der jetzt sichtbar in der Ausgabe?

                                          D 1 Reply Last reply Reply Quote 0
                                          • D
                                            digitalnaive @wendy2702 last edited by

                                            Kann ich leider erst heute Abend machen.

                                            Aktuelles DMESG liefert keinerlei Werte zu FTDI. Das ist schon mal kein gutes Zeichen.

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate
                                            FAQ Cloud / IOT
                                            HowTo: Node.js-Update
                                            HowTo: Backup/Restore
                                            Downloads
                                            BLOG

                                            930
                                            Online

                                            31.6k
                                            Users

                                            79.4k
                                            Topics

                                            1.3m
                                            Posts

                                            281
                                            3634
                                            1692238
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo