    Datenpunkt von ioBroker nach Variable in CCU schreiben

    This topic has been deleted. Only users with topic management privileges can see it.
    • sigi234
      sigi234 Forum Testing Most Active @paul53 last edited by sigi234

      @paul53

      Ok, funktioniert aber seit Jahren.....😇

      Was mache ich Falsch?

      Screenshot (3093)_LI.jpg

      1 Reply Last reply Reply Quote 0
      • paul53
        paul53 @hanan last edited by

        @hanan sagte:

        Was mache ich falsch?

        Schau mal in den vom Blockly generierten Javascript-Code. In Zeile 25 stimmt wahrscheinlich eine Datenpunkt-ID nicht.

        1 Reply Last reply Reply Quote 0
        • hanan
          hanan last edited by

          Hallo paul53
          Die Fehlermeldung kommt auch nur bei einem Bindeblock.

          14:20:01.795 warn javascript.0 at Object.<anonymous> (script.js.common.Test.Weatherman1:5:5)
          14:21:02.162 warn javascript.0 at Object.<anonymous> (script.js.common.Test.Weatherman1:5:5)
          14:21:02.165 warn javascript.0 at Object.<anonymous> (script.js.common.Test.Weatherman1:5:5)
          14:21:15.506 warn javascript.0 at Object.<anonymous> (script.js.common.Test.Weatherman1:5:5)
          14:21:15.511 warn javascript.0 at Object.<anonymous> (script.js.common.Test.Weatherman1:5:5)
          14:21:15.512 warn javascript.0 at Object.<anonymous> (script.js.common.Test.Weatherman1:5:5)

          Hier der Blockly-Code:

          on({id: "wiffi-wz.0.root.192_168_1_13.Systeminfo.zeitpunkt"/*zeitpunkt*/, change: "any"}, function (obj) {
            var value = obj.state.val;
            var oldValue = obj.oldState.val;
            on({id: 'wiffi-wz.0.root.192_168_1_13.w_lux', change: "ne"}, function (obj) {
              setState('hm-rega.0.3716', obj.state.val);
            });});
          

          Hast Du eventuell einen Tipp?

          Ich würde es gerne auch in JS schreiben, doch es sind 28 Datenpunkte die überprüft werde sollen und nur die jeweiligen Änderung auf die CCU geschrieben werden. Der Datenpunkt Zeitpunkt wird immer aktuallisiert und soll der Trigger sein.

          paul53 1 Reply Last reply Reply Quote 0
          • paul53
            paul53 @hanan last edited by paul53

            @hanan sagte:

            Der Datenpunkt Zeitpunkt wird immer aktuallisiert und soll der Trigger sein.

            Dann darfst Du nicht den Block binde verwenden, denn der enthält einen Trigger.
            Besser: Lass den Trigger "zeitpunkt" weg !

            1 Reply Last reply Reply Quote 0
            • hanan
              hanan last edited by hanan

              Habe ich jetzt versucht, doch es kommen immer noch Warnmeldungen...

              Hier der Blockly-Code:
              Blockly.jpg

              on({id: 'wiffi-wz.0.root.192_168_1_13.w_ip', change: "ne"}, function (obj) {
               setState('hm-rega.0.4026', obj.state.val);
              });
              on({id: 'wiffi-wz.0.root.192_168_1_13.w_temperatur', change: "ne"}, function (obj) {
               setState('hm-rega.0.3707', obj.state.val);
              });
              on({id: 'wiffi-wz.0.root.192_168_1_13.w_feuchte_rel', change: "ne"}, function (obj) {
               setState('hm-rega.0.3708', obj.state.val);
              });
              on({id: 'wiffi-wz.0.root.192_168_1_13.w_barometer', change: "ne"}, function (obj) {
               setState('hm-rega.0.3709', obj.state.val);
              });
              on({id: 'wiffi-wz.0.root.192_168_1_13.w_wind_mittel', change: "ne"}, function (obj) {
               setState('hm-rega.0.3710', obj.state.val);
              })
              
              paul53 1 Reply Last reply Reply Quote 0
              • paul53
                paul53 @hanan last edited by

                @hanan sagte:

                immer noch Warnmeldungen

                Schau mal nach dem Datenpunkt 'hm-rega.0.3709'. Gibt es ihn ?

                1 Reply Last reply Reply Quote 0
                • hanan
                  hanan last edited by

                  Jep...

                  0511aa36-5f34-436a-a76b-7a4965d8618b-image.png

                  Die Warnmeldungen kommen bei allen Datenpunkten.

                  paul53 1 Reply Last reply Reply Quote 0
                  • paul53
                    paul53 @hanan last edited by

                    @hanan sagte:

                    Die Warnmeldungen kommen bei allen Datenpunkten.

                    Die Daten werden aber geschrieben (es sind ja "nur" Warnungen). Welchen Typ haben die Rega-Datenpunkte ? Den gleichen wie die Quell-Datenpunkte ?

                    1 Reply Last reply Reply Quote 0
                    • hanan
                      hanan last edited by hanan

                      Jep, die Daten werden geschrieben.

                      Hier die Datenpunkte im ioBroker:
                      aedffcd2-9a69-4085-85ea-dee5ab86dd16-image.png

                      In der CCU sind alle SV als Zahl ausser...
                      Zeichenkette = w_barotrend und w_windrichtung
                      Logikwert = w_regenmelder und w_sonne_scheint

                      paul53 1 Reply Last reply Reply Quote 0
                      • paul53
                        paul53 @hanan last edited by

                        @hanan sagte:

                        Hier die Datenpunkte im ioBroker:

                        Daran kann man nicht erkennen, welchen Datentyp die Werte tasächlich haben. Erzeuge mal ein Log:
                        debug output von Typ von Wert von Objekt w_barometer

                        1 Reply Last reply Reply Quote 0
                        • hanan
                          hanan last edited by

                          Hier die Daten vom Datenpunkt w_barometer:

                          {
                          "from": "system.adapter.wiffi-wz.0",
                          "ts": 1557058406498,
                          "common": {
                          "name": 3,
                          "desc": "nn_luftdruck",
                          "unit": "mb",
                          "role": "value.pressure",
                          "id": "w_barometer",
                          "type": "number",
                          "read": true,
                          "write": false
                          },
                          "native": {},
                          "acl": {
                          "object": 1638,
                          "owner": "system.user.admin",
                          "ownerGroup": "system.group.administrator",
                          "state": 1638
                          },
                          "_id": "wiffi-wz.0.root.192_168_1_13.w_barometer",
                          "type": "state"
                          }

                          paul53 1 Reply Last reply Reply Quote 0
                          • paul53
                            paul53 @hanan last edited by

                            @hanan sagte:

                            Hier die Daten vom Datenpunkt w_barometer:

                            common.type: "number" garantiert leider nicht, dass der Wert tatsächlich eine Zahl enthält. Deshalb erzeuge bitte den Log-Eintrag.

                            1 Reply Last reply Reply Quote 0
                            • hanan
                              hanan last edited by

                              javascript.0	2019-05-05 17:55:53.656	warn	at TCP.onread (net.js:601:20)
                              javascript.0	2019-05-05 17:55:53.656	warn	at Socket.Readable.push (_stream_readable.js:208:10)
                              javascript.0	2019-05-05 17:55:53.656	warn	at readableAddChunk (_stream_readable.js:250:11)
                              javascript.0	2019-05-05 17:55:53.656	warn	at addChunk (_stream_readable.js:263:12)
                              javascript.0	2019-05-05 17:55:53.656	warn	at Socket.emit (events.js:211:7)
                              javascript.0	2019-05-05 17:55:53.656	warn	at emitOne (events.js:116:13)
                              javascript.0	2019-05-05 17:55:53.656	warn	at Socket._ultron.on (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/ws/lib/WebSocket.js:138:22)
                              javascript.0	2019-05-05 17:55:53.656	warn	at Receiver.add (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/ws/lib/Receiver.js:139:10)
                              javascript.0	2019-05-05 17:55:53.656	warn	at Receiver.startLoop (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/ws/lib/Receiver.js:165:16)
                              javascript.0	2019-05-05 17:55:53.656	warn	at Receiver.getData (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/ws/lib/Receiver.js:330:12)
                              javascript.0	2019-05-05 17:55:53.656	warn	at Receiver.dataMessage (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/ws/lib/Receiver.js:389:14)
                              javascript.0	2019-05-05 17:55:53.656	warn	at Receiver._receiver.onmessage (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/ws/lib/WebSocket.js:141:47)
                              javascript.0	2019-05-05 17:55:53.656	warn	at WebSocket.emit (events.js:211:7)
                              javascript.0	2019-05-05 17:55:53.656	warn	at emitOne (events.js:116:13)
                              javascript.0	2019-05-05 17:55:53.656	warn	at WebSocket.onMessage (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/ws/lib/EventTarget.js:99:16)
                              javascript.0	2019-05-05 17:55:53.656	warn	at WebSocket.ws.onmessage (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/engine.io-client/lib/transports/websocket.js:147:10)
                              javascript.0	2019-05-05 17:55:53.656	warn	at WS.Transport.onData (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/engine.io-client/lib/transport.js:137:8)
                              javascript.0	2019-05-05 17:55:53.656	warn	at WS.Transport.onPacket (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/engine.io-client/lib/transport.js:145:8)
                              javascript.0	2019-05-05 17:55:53.656	warn	at WS.Emitter.emit (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/component-emitter/index.js:133:20)
                              javascript.0	2019-05-05 17:55:53.656	warn	at WS.<anonymous> (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/engine.io-client/lib/socket.js:273:10)
                              javascript.0	2019-05-05 17:55:53.656	warn	at Socket.onPacket (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/engine.io-client/lib/socket.js:456:14)
                              javascript.0	2019-05-05 17:55:53.656	warn	at Socket.Emitter.emit (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/component-emitter/index.js:133:20)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Socket.<anonymous> (/opt/iobroker/node_modules/component-bind/index.js:21:15)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Manager.ondata (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/manager.js:335:16)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Decoder.add (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-parser/index.js:251:12)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Decoder.Emitter.emit (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/component-emitter/index.js:133:20)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Decoder.<anonymous> (/opt/iobroker/node_modules/component-bind/index.js:21:15)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Manager.ondecoded (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/manager.js:345:8)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Manager.Emitter.emit (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/component-emitter/index.js:133:20)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Manager.<anonymous> (/opt/iobroker/node_modules/component-bind/index.js:21:15)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Socket.onpacket (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/socket.js:236:12)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Socket.onevent (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/socket.js:278:10)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Socket.Emitter.emit (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/component-emitter/index.js:133:20)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Socket.<anonymous> (/opt/iobroker/node_modules/iobroker.js-controller/lib/states/statesInMemClient.js:52:30)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Object.change (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:3425:37)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Object.stateChange (/opt/iobroker/node_modules/iobroker.javascript/main.js:364:25)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Object.callback (/opt/iobroker/node_modules/iobroker.javascript/lib/sandbox.js:963:38)
                              javascript.0	2019-05-05 17:55:53.655	warn	at Object.<anonymous> (script.js.common.Test.nach_CCU:2:3)
                              javascript.0	2019-05-05 17:55:53.655	warn	at setState (/opt/iobroker/node_modules/iobroker.javascript/lib/sandbox.js:1258:20)
                              javascript.0	2019-05-05 17:55:53.655	warn	Wrong type of hm-rega.0.3709: "string". Please fix, while deprecated and will not work in next versions.
                              
                              paul53 1 Reply Last reply Reply Quote 0
                              • paul53
                                paul53 @hanan last edited by

                                @hanan sagte:

                                Wrong type of hm-rega.0.3709: "string".

                                Das habe ich vermutet. Die Werte müssen erst in eine Zahl gewandelt werden.

                                1 Reply Last reply Reply Quote 0
                                • hanan
                                  hanan last edited by

                                  Erst mal Danke für den Tipp.
                                  Muss mal im Forum schauen wie ich dieses umwandeln kann, hoffe ich finde etwas.

                                  paul53 1 Reply Last reply Reply Quote 0
                                  • paul53
                                    paul53 @hanan last edited by paul53

                                    @hanan sagte:

                                    wie ich dieses umwandeln kann

                                    Blockly_Triggerwert_nach_Zahl.JPG

                                    Wert ist eine Eigenschaft des Triggerdatenpunktes (Blöcke Trigger)

                                    1 Reply Last reply Reply Quote 0
                                    • hanan
                                      hanan last edited by

                                      Hallo paul53
                                      Hat supi geklappt.
                                      Besten Dank nochmals für Deine Hilfe..

                                      1 Reply Last reply Reply Quote 0
                                      • First post
                                        Last post

                                      Support us

                                      ioBroker
                                      Community Adapters
                                      Donate

                                      765
                                      Online

                                      31.9k
                                      Users

                                      80.1k
                                      Topics

                                      1.3m
                                      Posts

                                      4
                                      21
                                      1691
                                      Loading More Posts
                                      • Oldest to Newest
                                      • Newest to Oldest
                                      • Most Votes
                                      Reply
                                      • Reply as topic
                                      Log in to reply
                                      Community
                                      Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                      The ioBroker Community 2014-2023
                                      logo