    4. RPC 1.9.11 Frage zu CONTOL_MODE

    NEWS

    • Neuer Blog: Fotos und Eindrücke aus Solingen

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    SOLVED RPC 1.9.11 Frage zu CONTOL_MODE

    This topic has been deleted. Only users with topic management privileges can see it.
    • dslraser
      dslraser Forum Testing Most Active @foxriver76 last edited by

      @foxriver76
      wird den bei der Android App die gleiche API verwendet ?
      Da geht es wie es soll.

      Screenshot_20190507-210531_TinyMatic.jpg

      foxriver76 1 Reply Last reply Reply Quote 0
      • R
        RandyAndy last edited by Negalein

        Ich habe das über Control_Mode gelöst, den muss man auf 1 Setzen. Dann wird der Temperaturregler von Auto auf manu umgestellt. Die Temperaturregler sind nach einem Stromausfall oder wenn man die Sicherung herausgenommen hat nach dem Start typisch immer im Auto-Modus, d.h. die Regler scheinen sich den letzten Status nicht zu merken.
        Anbei ein Screenshot meines Blockly Skripts, das durch einen Button Druck getriggert wird.

        2019-06-24 23_07_34-javascript - ioBroker.png

        Durch den Befehl steuere Regler:1.CONTROL_MODE mit 1 wird der SET_POINT_MODE auf 1 geändert. Den Set_POINT_MODE direkt zu ändern hat nichts bewirkt. Warum der CONTROL_MODE ein Indikator ist erschliesst sich mir leider nicht ganz.

        Ich bin mir nicht ganz sicher aber ich denke das funktioniert nur mit der aktuellsten FW des Temperaturreglers.

        Ich hoffe das hilft dem Ein oder Anderen.

        RandyAndy

        1 Reply Last reply Reply Quote 1
        • paul53
          paul53 @dslraser last edited by

          @dslraser sagte:

              "read": false,
              "write": true,
              "min": 0,
              "max": 3,
              "role": "indicator",
          

          "write": true und "role": "indicator" widersprechen sich. Was passiert auf der CCU, wenn Du im Reiter "Objekte" den Wert 3 eingibst ?

          dslraser 2 Replies Last reply Reply Quote 0
          • foxriver76
            foxriver76 Developer @dslraser last edited by

            @dslraser ist das dieses tinymatic? Glaube die nutzen das https://www.homematic-inside.de/software/xml-api

            dslraser 1 Reply Last reply Reply Quote 0
            • dslraser
              dslraser Forum Testing Most Active @paul53 last edited by

              @paul53
              auf der CCU passiert nichts und der Wert in ioBroker bleibt rot und bei bestätigt false.
              Es werden zwar einige Datenunkte in ioBroker aktulisiert, sonst kann ich keinen Unterschied sehen.

              paul53 1 Reply Last reply Reply Quote 0
              • dslraser
                dslraser Forum Testing Most Active @foxriver76 last edited by

                @foxriver76
                ja, ist tinymatic

                1 Reply Last reply Reply Quote 0
                • paul53
                  paul53 @dslraser last edited by

                  @dslraser sagte:

                  auf der CCU passiert nichts und der Wert in ioBroker bleibt rot und bei bestätigt false.

                  Dann funktioniert offenbar der hm-rpc-Adapter mit diesen Geräten nicht so wie er soll.

                  1 Reply Last reply Reply Quote 0
                  • dslraser
                    dslraser Forum Testing Most Active @paul53 last edited by

                    @paul53

                    Edit: Wenn ich eine 3 eingebe passiert noch nichts. Wenn ich aber anschließend eine 0 eingebe wird doch auf Auto Modus gewechselt. Mit 1 wechselt es dann wieder auf Manu Mode zurück, da brauche ich keine 0 hinterher eingeben.

                    paul53 1 Reply Last reply Reply Quote 0
                    • paul53
                      paul53 @dslraser last edited by paul53

                      @dslraser

                        "_id": "hm-rpc.2.INT0000001.1.CONTROL_MODE",
                      

                      Die ID kommt mir komisch vor. Ist das eine Gruppe ? Gibt es auch einen Wandthermostaten in der Gruppe ?

                      dslraser 2 Replies Last reply Reply Quote 0
                      • dslraser
                        dslraser Forum Testing Most Active @paul53 last edited by

                        @paul53
                        ja, ist eine Gruppe mit Wandthermostat

                        paul53 1 Reply Last reply Reply Quote 0
                        • dslraser
                          dslraser Forum Testing Most Active @paul53 last edited by dslraser

                          @paul53
                          aber das Wandthermostat alleine sieht genau so aus

                          {
                            "type": "state",
                            "common": {
                              "def": 0,
                              "type": "number",
                              "read": false,
                              "write": true,
                              "min": 0,
                              "max": 3,
                              "role": "indicator",
                              "name": "Wandthermostat Schlafzimmer:1.CONTROL_MODE"
                            },
                            "native": {
                              "MIN": 0,
                              "OPERATIONS": 2,
                              "MAX": 3,
                              "FLAGS": 1,
                              "ID": "CONTROL_MODE",
                              "TYPE": "INTEGER",
                              "DEFAULT": 0,
                              "CONTROL": "HEATING_CONTROL_HMIP.CONTROL_MODE"
                            },
                            "from": "system.adapter.hm-rpc.0",
                            "ts": 1557074946776,
                            "_id": "hm-rpc.0.xxx.1.CONTROL_MODE",
                            "acl": {
                              "object": 1636,
                              "state": 1636,
                              "owner": "system.user.Heiko",
                              "ownerGroup": "system.group.administrator"
                            }
                          }
                          
                          1 Reply Last reply Reply Quote 0
                          • paul53
                            paul53 @dslraser last edited by paul53

                            @dslraser sagte:

                            Gruppe mit Wandthermostat

                            Funktioniert es vielleicht besser, wenn der Wandthermostat von ioBroker gesteuert wird ?

                            Anmerkung: Ich kenne die Gruppen nicht selbst, denn meine eingemottete CCU1 kannte noch keine Gruppen und jetzt nutze ich keine ReGa.

                            dslraser 1 Reply Last reply Reply Quote 0
                            • dslraser
                              dslraser Forum Testing Most Active @paul53 last edited by

                              @paul53
                              macht keinen Unterschied.

                              1 Reply Last reply Reply Quote 0
                              • dslraser
                                dslraser Forum Testing Most Active last edited by dslraser

                                @foxriver76
                                @paul53

                                @BBTown war mal so nett einen "normalen HM RAW" zu posten, da wird der Unterschied deutlich.

                                Stammt von hier

                                {
                                  "from": "system.adapter.hm-rega.0",
                                  "user": "system.user.admin",
                                  "ts": 1550316196723,
                                  "common": {
                                    "name": "Heizung Diele.CONTROL_MODE",
                                    "type": "number",
                                    "role": "indicator",
                                    "def": 0,
                                    "min": 0,
                                    "max": 3,
                                    "read": true,
                                    "write": false,
                                    "states": {
                                      "0": "AUTO-MODE",
                                      "1": "MANU-MODE",
                                      "2": "PARTY-MODE",
                                      "3": "BOOST-MODE"
                                    }
                                  },
                                  "native": {
                                    "CONTROL": "HEATING_CONTROL.CONTROL_MODE",
                                    "ID": "CONTROL_MODE",
                                    "TYPE": "ENUM",
                                    "UNIT": "",
                                    "DEFAULT": 0,
                                    "FLAGS": 1,
                                    "MAX": 3,
                                    "MIN": 0,
                                    "OPERATIONS": 5,
                                    "TAB_ORDER": 0,
                                    "VALUE_LIST": [
                                      "AUTO-MODE",
                                      "MANU-MODE",
                                      "PARTY-MODE",
                                      "BOOST-MODE"
                                    ]
                                  },
                                  "acl": {
                                    "object": 1636,
                                    "owner": "system.user.admin",
                                    "ownerGroup": "system.group.administrator",
                                    "state": 1636
                                  },
                                  "_id": "hm-rpc.0.KEQ0000000.4.CONTROL_MODE",
                                  "type": "state"
                                }
                                
                                paul53 1 Reply Last reply Reply Quote 0
                                • paul53
                                  paul53 @dslraser last edited by paul53

                                  @dslraser sagte:

                                      "read": true,
                                      "write": false,
                                  ...
                                  "_id": "hm-rpc.0.KEQ0000000.4.CONTROL_MODE",
                                  

                                  Das ist kein HMIP-Gerät, sondern HM klassisch (Heizkörperthemostat). So sieht es bei mir auch aus.

                                  dslraser 1 Reply Last reply Reply Quote 0
                                  • dslraser
                                    dslraser Forum Testing Most Active @paul53 last edited by

                                    @paul53
                                    Ja, das meinte ich ja mit

                                    "normalen HM RAW"

                                    Ich wollte nur den Unterschied zu HMIP aufzeigen.

                                    1 Reply Last reply Reply Quote 0
                                    • R
                                      RandyAndy last edited by

                                      Hi

                                      ich sehe diesen Post ers jetzt. Die Umstellung zwischen Auto und Manu hat mich auch einige Zeit gekostet aber am Ende habe ich es dann lösen können. Wenn das Thema noch interessant ist, dann kann ich es gerne posten wie man das macht

                                      RandyAndy

                                      dslraser M falke69 3 Replies Last reply Reply Quote 0
                                      • dslraser
                                        dslraser Forum Testing Most Active @RandyAndy last edited by

                                        @RandyAndy
                                        gern, her damit.

                                        1 Reply Last reply Reply Quote 0
                                        • M
                                          Michi68 @RandyAndy last edited by

                                          @RandyAndy
                                          Hätte ich auch Interesse dran

                                          1 Reply Last reply Reply Quote 0
                                          • R
                                            RandyAndy last edited by Negalein

                                            Ich habe das über Control_Mode gelöst, den muss man auf 1 Setzen. Dann wird der Temperaturregler von Auto auf manu umgestellt. Die Temperaturregler sind nach einem Stromausfall oder wenn man die Sicherung herausgenommen hat nach dem Start typisch immer im Auto-Modus, d.h. die Regler scheinen sich den letzten Status nicht zu merken.
                                            Anbei ein Screenshot meines Blockly Skripts, das durch einen Button Druck getriggert wird.

                                            2019-06-24 23_07_34-javascript - ioBroker.png

                                            Durch den Befehl steuere Regler:1.CONTROL_MODE mit 1 wird der SET_POINT_MODE auf 1 geändert. Den Set_POINT_MODE direkt zu ändern hat nichts bewirkt. Warum der CONTROL_MODE ein Indikator ist erschliesst sich mir leider nicht ganz.

                                            Ich bin mir nicht ganz sicher aber ich denke das funktioniert nur mit der aktuellsten FW des Temperaturreglers.

                                            Ich hoffe das hilft dem Ein oder Anderen.

                                            RandyAndy

                                            1 Reply Last reply Reply Quote 1
                                            • falke69
                                              falke69 @RandyAndy last edited by falke69

                                              @RandyAndy

                                              Hi, auch wenn der Post schon fast ein Jahr alt ist, habe alles nachbebaut, aber es funktioniert bei mir leider nicht.
                                              Ich beiß mir auch schon seit einigen Tagen die Zähne daran aus?

                                              Danke!

                                              R 1 Reply Last reply Reply Quote 0
                                              • First post
                                                Last post

                                              Support us

                                              ioBroker
                                              Community Adapters
                                              Donate

                                              895
                                              Online

                                              31.9k
                                              Users

                                              80.1k
                                              Topics

                                              1.3m
                                              Posts

                                              hmip
                                              6
                                              35
                                              3755
                                              Loading More Posts
                                              • Oldest to Newest
                                              • Newest to Oldest
                                              • Most Votes
                                              Reply
                                              • Reply as topic
                                              Log in to reply
                                              Community
                                              Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                              The ioBroker Community 2014-2023
                                              logo