      Hallo AlCalzone,

      ich bekomme leider keinen meiner vier G-Homa Adapter hinzugefügt.

      Folgenden Log erhalte ich nach deiner Anleitung:

       starting. Version 0.4.0 in /opt/iobroker/node_modules/iobroker.g-homa, node: v6.13.0
      bootstrap_node.js:256
            get: function() {
                         ^
      
      RangeError: Maximum call stack size exceeded
          at get (bootstrap_node.js:256:20)
          at Log.error (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4927:17)
          at Console.console.error (/opt/iobroker/node_modules/iobroker.g-homa/build/main.js:65:73)
          at Log.error (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4927:25)
          at Console.console.error (/opt/iobroker/node_modules/iobroker.g-homa/build/main.js:65:73)
          at Log.error (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4927:25)
          at Console.console.error (/opt/iobroker/node_modules/iobroker.g-homa/build/main.js:65:73)
          at Log.error (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4927:25)
          at Console.console.error (/opt/iobroker/node_modules/iobroker.g-homa/build/main.js:65:73)
          at Log.error (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4927:25)
      

      Kannst du mir sagen, was ich da falsch mache?

      Gruß

      Thomas

      1 Reply Last reply Reply Quote 0
      • T
        tschuberth last edited by

        Das Problem hat sich von selbst "gelöst". Ich weiß zwar nicht warum, aber über Nacht haben sich die Steckdosen dann in die Instanz geschrieben und lassen sich wie gewollt steuern.

        1 Reply Last reply Reply Quote 0
        • M
          Maverick82 last edited by

          Hallo zusammen,

          ich habe mir auch zwei G-Homa EMW302WF zum testen geholt.

          Ich habe allerdings folgendes Setup:

          • iobroker 192.168.1.1

          • G-Homas im 192.168.0.0/24 Netz

          Ist es möglich die G-Homas per iobroker Adapter netzübergreifend zu finden und einzubinden?

          Wenn ich es richtig verstehe scannt der Adapter per Netzbroadcast. Kann man dies ändern, ggf. auch per Kommandozeile?

          Oder wäre es möglich den Adapter dahingehend zu ändern, dass man über die Instanz statische Einträge hinzufügen kann, damit iobroker die G-Homas per Unicast erreichen kann.

          1 Reply Last reply Reply Quote 0
          • P
            piForscher last edited by

            @AlCalzone: Kann ich beim testen helfen ?

            Ich würde mich sehr freuen, wenn die Kombi aus g-homa und Magic-Ufo (Wifilight) Adapter stabil funktionieren würde.

            Aber ich bin nicht firm genug, um im Code nach dem Problem zu forschen… 😞

            piForscher

            1 Reply Last reply Reply Quote 0
            • AlCalzone
              AlCalzone Developer last edited by

              @piForscher:

              @AlCalzone: Kann ich beim testen helfen ?

              Ich würde mich sehr freuen, wenn die Kombi aus g-homa und Magic-Ufo (Wifilight) Adapter stabil funktionieren würde.

              Aber ich bin nicht firm genug, um im Code nach dem Problem zu forschen… 😞 `
              Du könntest mal eine Runde mit dem Magic-Ufo sprechen. Der Adapter enthält eine dependency "(node-)g-homa", die sich im node_modules Ordner befinden sollte.

              Folge dieser Anleitung => https://github.com/AlCalzone/node-g-hom … -interface

              Mit AT+H\r bekommst du eine Reihe von Befehlen, die dein Modul unterstützt. http://www.sabreadv.com/wp-content/uploads/HF-LPC100-User-Manual-V1.0.pdf findest du die Erklärung dazu. ( <cr>ist einfach \r im interface)

              Ich würde vermuten, dass AT+LVER\r und verwandte Befehle oder AT+NETP\r helfen könnten, die Geräte zu identifizieren.</cr>

              1 Reply Last reply Reply Quote 0
              • S
                Sphinxapfel7 last edited by

                Hallo, weiß jemand warum ich meine G-Homa Steckdosen nicht mit IOBroker verbinden kann?

                IP-Adresse vom IOBroker stimmt, Port ist 50000 und WLan-Passwort passt auch.

                Sie blinken zum hinzufügen schnell aber verbinden sich nicht. Adapter-Version ist 0.4.0

                Gruß Daniel
                7272_09-02-_2019_10-39-32.jpg

                1 Reply Last reply Reply Quote 0
                • M
                  m76 last edited by

                  Hallo,

                  der Adapter "ersetzt" ja den g-homa Server, also kein Funk mehr zu den G-Homa Servern.
                  Ginge auch beides als Option?

                  Da es noch keine Views gibt (oder doch?), würde ich gerne nur eine G-homa Steckdose einbinden, aber nicht alle, ginge das? Könnte hier jemand einen Filter einbauen bzw. gibt es das schon?

                  1 Reply Last reply Reply Quote 0
                  • R
                    RichieXX last edited by RichieXX

                    Ich bekomme seit einer Weile Fehler im Log, dass der Adapter immer wieder beendet wird:

                    2019-08-06 21:30:50.638  - info: g-homa.0 starting. Version 0.4.0 in /opt/iobroker/node_modules/iobroker.g-homa, node: v8.16.0
                    2019-08-06 21:30:50.742  - info: g-homa.0 enumerating known plugs...
                    2019-08-06 21:30:50.858  - info: g-homa.0 found plug with id 85215c (offline)
                    2019-08-06 21:30:50.858  - info: g-homa.0 starting server...
                    2019-08-06 21:30:50.875  - info: g-homa.0 server started on port 50000
                    2019-08-06 21:30:50.883  - info: g-homa.0 searching plugs
                    2019-08-06 21:30:55.072  - info: g-homa.0 Added plug with ID 85215c
                    2019-08-06 21:30:58.162  - info: g-homa.0 Added plug with ID 85215c
                    2019-08-06 21:31:08.720  - info: admin.0 Unsubscribe from all states, except system's, because over 3 seconds the number of events is over 200 (in last second 0)
                    2019-08-06 21:31:19.043  - error: g-homa.0 STDERR > Error: invalid data in the receive buffer
                    2019-08-06 21:31:19.069  - error: host.iobroker instance system.adapter.g-homa.0 terminated with code 1 ()
                    2019-08-06 21:31:19.069  - info: host.iobroker Restart adapter system.adapter.g-homa.0 because enabled
                    2019-08-06 21:31:49.084  - info: host.iobroker instance system.adapter.g-homa.0 started with pid 3533
                    
                    

                    Seit wann das ist, kann ich nicht genau sagen. Instanz und Adapter wurde gelöscht und wieder neu installiert, gleicher Fehler.

                    Woran könnte das liegen?

                    EDIT:
                    Habs gefunden: Nach Änderung des Serverports auf 60000 läuft der Adapter wieder. Eigenartig, da auf Port 50000 nichts anders läuft. Naja hauptsache es geht wieder.

                    1 Reply Last reply Reply Quote 0
                    • R
                      RichieXX last edited by

                      Nach Neustart von iobroker wieder das Problem. Jetzt nützt auch kein Wechsel des Ports mehr. Was ist da los?

                      1 Reply Last reply Reply Quote 0
                      • AlCalzone
                        AlCalzone Developer last edited by

                        @RichieXX sagte in [Aufruf] G-Homa Adapter testen:

                        invalid data in the receive buffer

                        Da scheint irgendwas ungültige Daten zu senden. Bitte starte den Adapter mal manuell:

                        1. Adapter im ioBroker stoppen
                        2. Konsole öffnen
                        3. Führe folgendes aus:
                          cd /opt/iobroker/node_modules/iobroker.g-homa/build
                          DEBUG=g-homa node main.js --force --logs
                          
                          und poste den Output hier.
                        1 Reply Last reply Reply Quote 0
                        • R
                          RichieXX last edited by RichieXX

                          @AlCalzone sagte in [Aufruf] G-Homa Adapter testen:

                          DEBUG=g-homa node main.js --force --logs

                          Naja mir sagt das (noch) nix:

                          root@iobroker:/opt/iobroker/node_modules/iobroker.g-homa/build# DEBUG=g-homa node main.js --force --logs
                          starting. Version 0.4.0 in /opt/iobroker/node_modules/iobroker.g-homa, node: v8.16.0
                          /opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4926
                                      Log.prototype.error = function (msg) {
                                                                     ^
                          
                          RangeError: Maximum call stack size exceeded
                              at Log.error (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4926:44)
                              at Console.console.error (/opt/iobroker/node_modules/iobroker.g-homa/build/main.js:65:73)
                              at Log.error (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4927:25)
                              at Console.console.error (/opt/iobroker/node_modules/iobroker.g-homa/build/main.js:65:73)
                              at Log.error (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4927:25)
                              at Console.console.error (/opt/iobroker/node_modules/iobroker.g-homa/build/main.js:65:73)
                              at Log.error (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4927:25)
                              at Console.console.error (/opt/iobroker/node_modules/iobroker.g-homa/build/main.js:65:73)
                              at Log.error (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4927:25)
                              at Console.console.error (/opt/iobroker/node_modules/iobroker.g-homa/build/main.js:65:73)
                          
                          
                          AlCalzone 1 Reply Last reply Reply Quote 0
                          • AlCalzone
                            AlCalzone Developer @RichieXX last edited by

                            @RichieXX Das ist auch was anderes 😓

                            Öffne bitte die Adapter-Datei mit einem Texteditor

                            nano /opt/iobroker/node_modules/iobroker.g-homa/build/main.js
                            

                            und ändere die Zeilen 37/38 von

                                        console.log = (msg) => adapter.log.debug("STDOUT > " + msg);
                                        console.error = (msg) => adapter.log.error("STDERR > " + msg);
                            

                            zu

                            //            console.log = (msg) => adapter.log.debug("STDOUT > " + msg);
                            //            console.error = (msg) => adapter.log.error("STDERR > " + msg);
                            

                            (also einfach je 2 Slashes davor).
                            Mit STRG+X schließen, Speichern mit Y bestätigen.

                            Danach bitte nochmal probieren.

                            1 Reply Last reply Reply Quote 0
                            • R
                              RichieXX last edited by RichieXX

                              @AlCalzone sagte in [Aufruf] G-Homa Adapter testen:

                              DEBUG=g-homa node main.js --force --logs

                              root@iobroker:~# cd /opt/iobroker/node_modules/iobroker.g-homa/build
                              root@iobroker:/opt/iobroker/node_modules/iobroker.g-homa/build# DEBUG=g-homa node main.js --force --logs
                              starting. Version 0.4.0 in /opt/iobroker/node_modules/iobroker.g-homa, node: v8.16.0
                              enumerating known plugs...
                              found plug with id 85215c (offline)
                              starting server...
                              server started on port 55555
                              searching plugs
                                g-homa connection from ::ffff:192.168.253.39 +0ms
                                g-homa connection from ::ffff:192.168.253.39 +2s
                                g-homa invalid data in the receive buffer +27s
                                g-homa ff000e8146000080005f00012a07055c63fe +0ms
                              Error: invalid data in the receive buffer
                                  at parseMessage (/opt/iobroker/node_modules/g-homa/build/server.js:62:15)
                                  at Socket.<anonymous> (/opt/iobroker/node_modules/g-homa/build/server.js:210:26)
                                  at emitOne (events.js:116:13)
                                  at Socket.emit (events.js:211:7)
                                  at addChunk (_stream_readable.js:263:12)
                                  at readableAddChunk (_stream_readable.js:250:11)
                                  at Socket.Readable.push (_stream_readable.js:208:10)
                                  at TCP.onread (net.js:601:20)
                              unhandled exception:invalid data in the receive buffer
                              > stack: Error: invalid data in the receive buffer
                                  at parseMessage (/opt/iobroker/node_modules/g-homa/build/server.js:62:15)
                                  at Socket.<anonymous> (/opt/iobroker/node_modules/g-homa/build/server.js:210:26)
                                  at emitOne (events.js:116:13)
                                  at Socket.emit (events.js:211:7)
                                  at addChunk (_stream_readable.js:263:12)
                                  at readableAddChunk (_stream_readable.js:250:11)
                                  at Socket.Readable.push (_stream_readable.js:208:10)
                                  at TCP.onread (net.js:601:20)
                              
                              

                              Das kommt, wenn der Plug im WLAN erreichbar ist:

                              root@iobroker:/opt/iobroker/node_modules/iobroker.g-homa/build# DEBUG=g-homa node main.js --force --logs
                              starting. Version 0.4.0 in /opt/iobroker/node_modules/iobroker.g-homa, node: v8.16.0
                              enumerating known plugs...
                              found plug with id 85215c (offline)
                              starting server...
                              server started on port 55555
                              searching plugs
                                g-homa connection from ::ffff:192.168.253.39 +0ms
                                g-homa connection from ::ffff:192.168.253.25 +573ms
                                g-homa unknown plug type detected. triggercode is 0x346b +164ms
                                g-homa the full payload was: 0x010ac0346b85215c01ff +1ms
                                g-homa connection from ::ffff:192.168.253.39 +1s
                              Added plug with ID 85215c
                                g-homa got update: 010ae0346b85215cfffe01811100000100000000 +889ms
                              Got updated info for Plug 85215c:
                                state: off
                                switched from: local
                                type: undefined
                              extendPlug: type = undefined, energyMeasurement != null: true
                              current != null: false
                              powerFactor != null: false
                              power != null: false
                              voltage != null: false
                              voltage in plug.energyMeasurement => false
                              current in plug.energyMeasurement => false
                              power in plug.energyMeasurement => false
                              powerFactor in plug.energyMeasurement => false
                                g-homa invalid data in the receive buffer +49s
                                g-homa ff00020103feff000e8146000080005f00012a07055c63fe +1ms
                              Error: invalid data in the receive buffer
                                  at parseMessage (/opt/iobroker/node_modules/g-homa/build/server.js:62:15)
                                  at Socket.<anonymous> (/opt/iobroker/node_modules/g-homa/build/server.js:210:26)
                                  at emitOne (events.js:116:13)
                                  at Socket.emit (events.js:211:7)
                                  at addChunk (_stream_readable.js:263:12)
                                  at readableAddChunk (_stream_readable.js:250:11)
                                  at Socket.Readable.push (_stream_readable.js:208:10)
                                  at TCP.onread (net.js:601:20)
                              unhandled exception:invalid data in the receive buffer
                              > stack: Error: invalid data in the receive buffer
                                  at parseMessage (/opt/iobroker/node_modules/g-homa/build/server.js:62:15)
                                  at Socket.<anonymous> (/opt/iobroker/node_modules/g-homa/build/server.js:210:26)
                                  at emitOne (events.js:116:13)
                                  at Socket.emit (events.js:211:7)
                                  at addChunk (_stream_readable.js:263:12)
                                  at readableAddChunk (_stream_readable.js:250:11)
                                  at Socket.Readable.push (_stream_readable.js:208:10)
                                  at TCP.onread (net.js:601:20)
                              
                              
                              AlCalzone 1 Reply Last reply Reply Quote 0
                              • AlCalzone
                                AlCalzone Developer @RichieXX last edited by AlCalzone

                                @RichieXX Danke. Ich habe die Vermutung, dass es hier Konflikte mit einem anderen Gerät gibt. Du kannst mir helfen, heraus zu finden, wie das reagiert, damit ich die automatische Erkennung im Adapter verbessern kann.

                                Dazu tue bitte folgendes:

                                1. Konsole öffnen, cd /opt/iobroker/node_modules/g-homa/build
                                2. node serial.js
                                3. Gebe eine der IPs ein: 192.168.253.39 oder 192.168.253.25, [ENTER]
                                4. Gebe ein: HF-A11ASSISTHREAD, dann [ENTER]
                                5. Wenn eine Antwort kommt, gebe (relativ zügig) ein +ok, dann [ENTER]
                                6. Gebe bitte nacheinander die folgenden Kommandos ein, jeweils gefolgt von [ENTER]. Wenn eine Antwort kommt, bitte hier posten:
                                  • AT+MID\r
                                  • AT+VER\r
                                  • AT+LVER\r
                                7. Wiederhole das ganze für die andere IP-Adresse. Das Programm kannst du jeweils per STRG+C beenden.
                                1 Reply Last reply Reply Quote 0
                                • R
                                  RichieXX last edited by RichieXX

                                  @AlCalzone sagte in [Aufruf] G-Homa Adapter testen:

                                  AT+LVER\r

                                  Aber gerne!
                                  Vorab als Info: Die IP ..39 ist ein MiLight LED Controller (YL5)

                                  root@iobroker:~# cd /opt/iobroker/node_modules/g-homa/build
                                  root@iobroker:/opt/iobroker/node_modules/g-homa/build# node serial.js
                                  G-Homa command line serial interface ready...
                                  
                                  Which IP to talk to? [default: Broadcast IP] 192.168.253.39
                                  talking to 192.168.253.39. enter "QUIT" to return to IP selection
                                  192.168.253.39 > HF-A11ASSISTHREAD
                                  192.168.253.39: 192.168.253.39,98D863080AB0,HF-LPT230
                                  192.168.253.39 > +ok
                                  192.168.253.39 > AT+MID\r
                                  192.168.253.39: +ok=HF-LPT230
                                  
                                  
                                  192.168.253.39 > AT+VER\r
                                  192.168.253.39: +ok=4.12.15 (2018-12-04 13:30 1M)
                                  
                                  
                                  192.168.253.39 > AT+LVER\r
                                  192.168.253.39 >
                                  
                                  

                                  Mit der ..25 (Das ist der einzige G-Home Plug den ich habe):

                                  root@iobroker:/opt/iobroker/node_modules/g-homa/build# node serial.js
                                  G-Homa command line serial interface ready...
                                  
                                  Which IP to talk to? [default: Broadcast IP] 192.168.253.25
                                  talking to 192.168.253.25. enter "QUIT" to return to IP selection
                                  192.168.253.25 > HF-A11ASSISTHREAD
                                  192.168.253.25: 192.168.253.25,F0FE6B85215C,G-Homa
                                  192.168.253.25 > +ok
                                  192.168.253.25 > AT+MID\r
                                  192.168.253.25: +ok=G-Homa
                                  
                                  
                                  192.168.253.25 > AT+VER\r
                                  192.168.253.25: +ok=GAO,Outdoor,1.8.26
                                  
                                  
                                  192.168.253.25 > AT+LVER\r
                                  192.168.253.25: +ok=08 (2015-06-05 11:12 16B)
                                  
                                  

                                  Wenn ich das also richtig verstehen, wird irgendwie der MiLight hier versuch mit einzubinden und dabei kommt es verständlicherweise zu Kommunikationsproblemen. Korrekt?

                                  AlCalzone 1 Reply Last reply Reply Quote 0
                                  • AlCalzone
                                    AlCalzone Developer @RichieXX last edited by AlCalzone

                                    @RichieXX Genau da liegt der Hase im Pfeffer. Bisher hatte nur noch keiner den Fall, dass gleich beides im selben Netzwerk hängt.
                                    Ich versuche bei Gelegenheit nochmal zu schauen, wie sich meine schon etwas ältere Dose ausgibt. Dann kann ich hoffentlich vermeiden, dass das MiLight mit dem G-Homa-Adapter spricht.

                                    Du wirst dich leider ein paar Tage gedulden müssen.

                                    1 Reply Last reply Reply Quote 0
                                    • R
                                      RichieXX last edited by

                                      Kein Problem. Mit dem Plug wird der Weihnachtsbaum geschaltet... 😁

                                      AlCalzone 1 Reply Last reply Reply Quote 0
                                      • AlCalzone
                                        AlCalzone Developer @RichieXX last edited by

                                        @RichieXX Probiere bitte mal die Version 0.5.0. Es kann sein, dass du dein MiLight vorher zurücksetzen musst.

                                        1 Reply Last reply Reply Quote 0
                                        • R
                                          RichieXX last edited by RichieXX

                                          Das ging dann doch schneller, wie ich erwartet habe 🙂

                                          Hab die 0.5.0 installiert und der Fehler tritt weiterhin auf (ohne Reset des Milight).
                                          Warum muss ich den Milight zurücksetzen? Reicht es wenn, ich dem eine neue IP verpasse?

                                          Das ist die Ausgabe mit 0.5.0 (Ich hab nach dem "ERR" nicht weitergemacht):

                                          root@iobroker:/opt/iobroker/node_modules/g-homa/build# node serial.js
                                          G-Homa command line serial interface ready...
                                          
                                          Which IP to talk to? [default: Broadcast IP] 192.168.253.39
                                          talking to 192.168.253.39. enter "QUIT" to return to IP selection
                                          192.168.253.39 > HF-A11ASSISTHREAD
                                          192.168.253.39: 192.168.253.39,98D863080AB0,HF-LPT230
                                          192.168.253.39 > +ok
                                          192.168.253.39: +ERR=-1
                                          
                                          
                                          192.168.253.39 >
                                          
                                          
                                          root@iobroker:/opt/iobroker/node_modules/iobroker.g-homa/build# DEBUG=g-homa node main.js --force --logs
                                          starting. Version 0.5.0 in /opt/iobroker/node_modules/iobroker.g-homa, node: v8.16.0
                                          enumerating known plugs...
                                          found plug with id 85215c (offline)
                                          starting server...
                                          server started on port 55555
                                          searching plugs
                                            g-homa connection from ::ffff:192.168.253.25 +0ms
                                            g-homa unknown plug type detected. triggercode is 0x346b +220ms
                                            g-homa the full payload was: 0x010ac0346b85215c01ff +0ms
                                            g-homa connection from ::ffff:192.168.253.39 +206ms
                                          Added plug with ID 85215c
                                            g-homa got update: 010ae0346b85215cfffe01811100000100000000 +2s
                                          Got updated info for Plug 85215c:
                                            state: off
                                            switched from: local
                                            type: undefined
                                          extendPlug: type = undefined, energyMeasurement != null: true
                                          current != null: false
                                          powerFactor != null: false
                                          power != null: false
                                          voltage != null: false
                                          voltage in plug.energyMeasurement => false
                                          current in plug.energyMeasurement => false
                                          power in plug.energyMeasurement => false
                                          powerFactor in plug.energyMeasurement => false
                                            g-homa connection from ::ffff:192.168.253.25 +972ms
                                            g-homa unknown plug type detected. triggercode is 0x346b +43ms
                                            g-homa the full payload was: 0x010ac0346b85215c01ff +1ms
                                          Added plug with ID 85215c
                                            g-homa got update: 010ae0346b85215cfffe01811100000100000000 +2s
                                          Got updated info for Plug 85215c:
                                            state: off
                                            switched from: local
                                            type: undefined
                                          extendPlug: type = undefined, energyMeasurement != null: true
                                          current != null: false
                                          powerFactor != null: false
                                          power != null: false
                                          voltage != null: false
                                          voltage in plug.energyMeasurement => false
                                          current in plug.energyMeasurement => false
                                          power in plug.energyMeasurement => false
                                          powerFactor in plug.energyMeasurement => false
                                            g-homa invalid data in the receive buffer +49s
                                            g-homa ff00020103feff000e814600008000000000000705d299fe +0ms
                                          unhandled exception:invalid data in the receive buffer
                                          > stack: Error: invalid data in the receive buffer
                                              at parseMessage (/opt/iobroker/node_modules/iobroker.g-homa/node_modules/g-homa/build/server.js:62:15)
                                              at Socket.<anonymous> (/opt/iobroker/node_modules/iobroker.g-homa/node_modules/g-homa/build/server.js:210:26)
                                              at emitOne (events.js:116:13)
                                              at Socket.emit (events.js:211:7)
                                              at addChunk (_stream_readable.js:263:12)
                                              at readableAddChunk (_stream_readable.js:250:11)
                                              at Socket.Readable.push (_stream_readable.js:208:10)
                                              at TCP.onread (net.js:601:20)
                                          
                                          
                                          AlCalzone 1 Reply Last reply Reply Quote 0
                                          • AlCalzone
                                            AlCalzone Developer @RichieXX last edited by

                                            @RichieXX sagte in [Aufruf] G-Homa Adapter testen:

                                            Warum muss ich den Milight zurücksetzen?

                                            Weil der weiterhin denkt, er muss mit dem G-Homa-Adapter reden. Die Einstellung bekommst du nur mit einem Reset wieder weg.

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            799
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            27
                                            177
                                            29798
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo