    • Bluefox
      Bluefox last edited by

      @vtec:

      @Bluefox:

      3. Что надо вызвать чтобы появилась страница с настройками для порта? "http://192.168.0.14/sec/?pt=0" ?

      А для P14 "http://192.168.0.14/sec/?pt=14" ? `

      http://192.168.0.14/sec/?pt=0
      filename="p0.png" index="2">~~

      http://192.168.0.14/sec/?pt=7
      filename="p7.png" index="1">~~

      http://192.168.0.14/sec/?pt=14
      filename="p14.png" index="0">~~ `
      Вроде начинает проясняться. Спасибо!

      > Надеюсь это только для симулятора :), не для парсинга %)
      Именно для парсинга. Я хочу считать все "…sec/?pt=Х" и извлечь настройки. А что есть какой то другой путь?

      1 Reply Last reply Reply Quote 0
      • V
        vtec last edited by

        Если я не ошибаюсь, то есть, т.к. есть скрипт который все настройки экспортирует.

        Работа с настройками

        При использовании ключа –ee (стирание EEPROM), часто необходимого при обновлении прошивки, из памяти устройства удаляется вся текущая нстройка портов. Это очень неудобно после перепрошивки восстанавливать настройки устройства и портов. Поэтому начиная с версии 1.1 скрипта megad-cfg.php была предусмотрена функция считывания и записи текущих настроек.

        Считывание конфигурации устройства и запись в файл megad.cfg

        php megad-cfg.php --ip 192.168.0.14 --read-conf megad.cfg -p sec

        Считывание конфигурации из файла и запись в устройство

        php megad-cfg.php --ip 192.168.0.14 --write-conf megad.cfg -p sec

        Сканирование всех устройств типа MegaD-328 в сети

        php megad-cfg.php –scan

        1 Reply Last reply Reply Quote 0
        • V
          vtec last edited by

          Сканирование (из php файла):

          $sock = socket_create(AF_INET, SOCK_DGRAM, SOL_UDP); 
          socket_set_option($sock, SOL_SOCKET, SO_BROADCAST, 1); 
          $broadcast_ip = preg_replace("/(\d+)\.(\d+)\.(\d+)\.(\d+)/", "$1.$2.$3.255", $local_ip);
          
          # Prepearing sockets
          if ( !empty($options['local-ip']) )
          $local_ip = $options['local-ip'];
          else
          {
          	$local_ip = gethostbyname(gethostname());
          	if ( empty($local_ip) || preg_match("/127\./", $local_ip) )
          	{
          		if ( preg_match("/^WIN/", PHP_OS) )
          		$local_ip = get_local_ip_win();
          		else
          		{
          			$find_ip = get_local_ip();
          			foreach ( $find_ip as $iface => $iface_ip)
          			{
          				if ( preg_match("/^192\.168/", $find_ip[$iface]) || preg_match("/^10\./", $find_ip[$iface]) )
          				$local_ip = $find_ip[$iface];
          			}
          		}
          	}
          
          	if ( !preg_match("/192\.168\./", $local_ip) && !preg_match("/10\.0\./", $local_ip) && !preg_match("/172\.16\./", $local_ip) )
          	{
          		echo "Unable to detect local network\nPlase, specify local IP-address with --local-ip\n";
          		exit;
          	}
          }
          
          # Scanning network for Mega-cool MegaD-devices ;)
          if ( array_key_exists('scan', $options) || array_key_exists('s', $options) )
          {
          
          	$broadcast_string = chr(0xAA).chr(0).chr(12);
          
          	socket_sendto($sock, $broadcast_string, strlen($broadcast_string), 0, $broadcast_ip, 52000);
          	usleep(100);
          	do
          	{
          		$pkt = fread($socket, 10);
          		if ( !empty($pkt) && ord($pkt[0]) == 0xAA )
          		echo ord($pkt[1]).".".ord($pkt[2]).".".ord($pkt[3]).".".ord($pkt[4])."\n";
          	}
          	while ( $pkt != false );
          }
          
          

          Чтение конфига

          	if ( array_key_exists('read-conf', $options) )
          	{
          		echo "Reading configuration... ";
          
          		$pages = array("cf=1", "cf=2");
          		//$pages = array();
          		$page = file_get_contents("http://".$options['ip']."/".$options['p']);
          		$ports = preg_replace("/.*\?pt=(\d+).*/", "$1", $page);
          		for ( $i = 0; $i <= $ports; $i++ )
          		$pages[] = "pt=$i";
          
          		$fh = fopen($options['read-conf'], "w");
          		$dom = new DOMDocument();
          		$preset_flag = 0;
          
          		for ( $i = 0; $i < count($pages); $i++ )
          		{
          			if ( $preset_flag == 1 )			
          			{
          				//echo "Setting preset 0\n";
          				$page = file_get_contents("http://".$options['ip']."/".$options['p']."/?cf=1&pr=0");
          				sleep(1);
          				$preset_flag = 2;
          			}
          
          			$page = file_get_contents("http://".$options['ip']."/".$options['p']."/?".$pages[$i]);
          
          			@$dom->loadHTML($page);
          			//$url = "http://".$options['ip']."/".$options['p']."/?";
          			$url = "";
          
          			$els=$dom->getelementsbytagname('input');
          			foreach($els as $inp)
          			{
          				if ( $inp->getAttribute('type') != "submit" )
          				{
          					$name=$inp->getAttribute('name');
          					//$value=urlencode($inp->getAttribute('value'));
          					if ( $inp->getAttribute('type') == "checkbox" )
          					{
          						if ( $inp->hasAttribute('checked') )
          						$value=1;
          						else
          						$value='';
          					}
          					else
          					$value=$inp->getAttribute('value');
          					if ( $name != "pt" )
          					{
          						if ( $name == "sl" && empty($value));
          						else
          						$url .= "$name=$value&";
          					}
          				}
          			}
          
          			$select = $dom->getelementsbytagname('select');
          
          			foreach($select as $elem)
          			{
          				$name=$elem->getAttribute('name');
          				$els=$elem->getelementsbytagname('option');
          
          				$sel_flag = 0;
          				foreach($els as $inp)
          				{
          					if ( $inp->hasAttribute('selected') )
          					{
          						//$name=$inp->getAttribute('name');
          						$value=urlencode($inp->getAttribute('value'));
          						$value=$inp->getAttribute('value');
          						$url .= "$name=$value&";
          						$sel_flag = 1;
          
          						if ( $pages[$i] == "cf=1" && $name == "pr" && !empty($value) )
          						{
          							$preset_flag = 1;
          							$stored_preset = $value;
          						}
          
          					}
          				}
          				// Хак ввиду того, что PHP DOM почему-то не может распарсить значение <> поля "Mode"
          				if ( $sel_flag == 0 && $name == "m" )
          				$url .= "m=3&";
          
          			}
          
          			$url = preg_replace("/&$/", "", $url);
          			fwrite($fh, "$url\n");
          		}
          
          		fclose($fh);
          
          		if ( $preset_flag == 2 )			
          		{
          			//echo "Setting preset 1\n";
          			$page = file_get_contents("http://".$options['ip']."/".$options['p']."/?cf=1&pr=$stored_preset");
          			sleep(1);
          		}
          
          		echo "OK\n";
          	}
          
          1 Reply Last reply Reply Quote 0
          • V
            vtec last edited by

            Посмотрел чтение конфига, там тот же парсинг идет :lol:

            А вот поиск устройств, всего две строки, отправка udp запроса бродкастом на порт 52000

            1 Reply Last reply Reply Quote 0
            • V
              vtec last edited by

              Из мануала:

              Если порт настроен как вход, то через слеш указывается значение счетчика входа. То есть там может быть не 0, а любая цифра.

              1 Reply Last reply Reply Quote 0
              • Bluefox
                Bluefox last edited by

                Спасибо. Вот теперь я знаю, что я буду делать на выходных.

                1 Reply Last reply Reply Quote 0
                • Bluefox
                  Bluefox last edited by

                  Что возвращают?

                  • http://192.168.0.14/sec

                  • http://192.168.0.14/sec/

                  • http://192.168.0.14/sec/?cf=1

                  • http://192.168.0.14/sec/?cf=2

                  Как HTML.

                  1 Reply Last reply Reply Quote 0
                  • V
                    vtec last edited by

                    MegaD-328 by [ab-log.ru](http://ab-log.ru) (fw: 3.30b5)
                    [Config](/sec/?cf=1)
                    -- Ports --
                    [P0 - IN](/sec/?pt=0)
                    [P1 - IN](/sec/?pt=1)
                    [P2 - IN](/sec/?pt=2)
                    [P3 - IN](/sec/?pt=3)
                    [P4 - IN](/sec/?pt=4)
                    [P5 - IN](/sec/?pt=5)
                    [P6 - IN](/sec/?pt=6)
                    [P7 - OUT](/sec/?pt=7)
                    [P8 - OUT](/sec/?pt=8)
                    [P9 - OUT](/sec/?pt=9)
                    [P10 - OUT](/sec/?pt=10)
                    [P11 - OUT](/sec/?pt=11)
                    [P12 - OUT](/sec/?pt=12)
                    [P13 - OUT](/sec/?pt=13)
                    [A6 - ADC](/sec/?pt=14)
                    [A7 - ADC](/sec/?pt=15)
                    

                    2. Тоже самое что и первое

                    3.

                    [Back](/sec) | [Megad-ID](/sec/?cf=2)
                    
                    <form action="/sec/">IP: 
                    Pwd: 
                    GW: 
                    SRV: 
                    Script: 
                    Preset: <select name="pr"><option value="0" selected="">Norm</option><option value="1">7I7O</option></select>
                    T check: 
                    Alarm T: 
                    Cur T: 37
                    </form>
                    
                    
                    [Back](/sec) | [Config](/sec/?cf=1)
                    
                    <form action="/sec/">Megad-ID: 
                    srv loop: 
                    </form>
                    
                    
                    1 Reply Last reply Reply Quote 0
                    • V
                      vtec last edited by

                      Предложение, если я выставляю режим кнопки "изменение", то соответственно, я буду использовать доп. режимы, это либо долгое нажатие, либо двойное, либо в сумме. Так вот предлагаю эти галочки у этих двух параметров по умолчанию чтобы были выставлены. Возможно такое?

                      1 Reply Last reply Reply Quote 0
                      • Bluefox
                        Bluefox last edited by

                        Дописал драйвер с твоей помощью. Можешь попробовать?

                        1 Reply Last reply Reply Quote 0
                        • H
                          Haus last edited by

                          Привет

                          В новой прошивке Megad есть поддержка датчиков 1wire DS18B20 и DS1990A (считыватели ключей iButton, EM-Marene с поддержкой протокола TM/1-wire). Вместо DHT22 определился DHT11, а вместо 1W тоже определился DHT11.

                          1W

                          [Back](/sec)
                          P7
                          temp:26.81
                          
                          <form action="/sec/">Type <select name="pty"><option value="255">NC</option><option value="0">In</option><option value="1">Out</option><option value="3" selected="">DSen</option></select>
                          Mode <select name="m"><option value="0">Norm</option><option value="1" selected="">></option><option value="2"><</option><option value="3"><></option></select>
                          Val 
                          Act 
                          Net  
                          Sensor: <select name="d"><option value="1">DHT11</option><option value="2">DHT22</option><option value="3" selected="">1W</option><option value="4">iB</option></select>
                          </form>
                          
                          

                          DHT22

                          [Back](/sec)
                          P0
                          temp:30.30
                          hum:38.70
                          
                          <form action="/sec/">Type <select name="pty"><option value="255">NC</option><option value="0">In</option><option value="1">Out</option><option value="3" selected="">DSen</option><option value="2">ADC</option></select>
                          Sensor: <select name="d"><option value="1">DHT11</option><option value="2" selected="">DHT22</option><option value="3">1W</option><option value="4">iB</option></select>
                          </form>
                          
                          

                          443_screencapture-192-168-1-68-8081-1440449132648.png
                          443_screencapture-192-168-1-14-sec-1440449943300.png

                          1 Reply Last reply Reply Quote 0
                          • Bluefox
                            Bluefox last edited by

                            В новой версии фирмваре поменялось значение аттрибута m для цифровых датчиков.

                            Я запрограммировал, как в новой версии. Кстати у неё есть номер, что бы я мог написать, что поддерживается версия от X.Y

                            Может кто нибудь попробовать новую версию?

                            cd /opt/iobroker
                            npm install https://github.com/ioBroker/ioBroker.megad/tarball/master
                            

                            > В новой прошивке Megad есть поддержка датчиков 1wire DS18B20 и DS1990A (считыватели ключей iButton, EM-Marene с поддержкой протокола TM/1-wire). Вместо DHT22 определился DHT11, а вместо 1W тоже определился DHT11.
                            А всё остальное работает???

                            1 Reply Last reply Reply Quote 0
                            • A
                              Andrei34 last edited by

                              В настройках параметры считываются шыкарно , но не записываются . А в Vis ни на что не реагирует 😞 .

                              1 Reply Last reply Reply Quote 0
                              • B
                                Bosya last edited by

                                Поигрался с новым драйвером и есть вопрос про длинное нажатие. Сейчас это работает как одинарное и двойное нажатие - true и сразу false, хотя я продолжаю держать кнопку.Хотелось бы иметь true после времени задержки, а false по отпусканию кнопки…

                                2015-09-03 13:54:06.920 - debug: inMem message * megad.0.p11_P11_long val=true, ack=true, ts=1441277647, from=system.adapter.megad.0, lc=1441277647

                                2015-09-03 13:54:07.126 - debug: inMem message * megad.0.p11_P11_long val=false, ack=true, ts=1441277647, from=system.adapter.megad.0, lc=1441277647

                                1 Reply Last reply Reply Quote 0
                                • V
                                  vtec last edited by

                                  А зачем?

                                  Вообще мега такой запрос отправляет, можете на свой скрипт направить мегу.

                                  1 Reply Last reply Reply Quote 0
                                  • B
                                    Bosya last edited by

                                    @vtec:

                                    А зачем? `
                                    Мне это нужно для димирования. На одиночный и двойной клик вешаем какие то функции - например включение/выключение свете, общее выключение света. На длинное нажатие вешаем плавную регулировку яркости.
                                    @vtec:

                                    Вообще мега такой запрос отправляет, можете на свой скрипт направить мегу. `
                                    Мега не может такой запрос отправлять, так как p11_P11_long, это чисто программная переменная, которая генерируется после определенной задержки длинного нажатия и выставляется в true, а вот после этого сразу скидывается в false. Не совсем логично. Если кому надо не для димирования, то он ловит только true и пользует его, а для димирования нужен реальный false который будет генерироваться по отпусканию кнопки.

                                    Свой скрипт написать конечно могу, но мне тогда придется переписывать полностью все одинарные, двойные нажатия и полностью отказаться от достаточно удобного драйвера.

                                    А чем может помешать правильная обработка конца нажатия?

                                    1 Reply Last reply Reply Quote 0
                                    • Bluefox
                                      Bluefox last edited by

                                      @Andrei34:

                                      В настройках параметры считываются шыкарно , но не записываются . `
                                      А можно логи? (Предварительно выставить на level=debug)

                                      @Andrei34:

                                      А в Vis ни на что не реагирует 😞 . `
                                      Поправил. Должно работать.

                                      Осталось выяснить, что делать с выходом в режиме PWM.

                                      1 Reply Last reply Reply Quote 0
                                      • Bluefox
                                        Bluefox last edited by

                                        @Bosya:

                                        Поигрался с новым драйвером и есть вопрос про длинное нажатие. Сейчас это работает как одинарное и двойное нажатие - true и сразу false, хотя я продолжаю держать кнопку.Хотелось бы иметь true после времени задержки, а false по отпусканию кнопки…

                                        2015-09-03 13:54:06.920 - debug: inMem message * megad.0.p11_P11_long val=true, ack=true, ts=1441277647, from=system.adapter.megad.0, lc=1441277647

                                        2015-09-03 13:54:07.126 - debug: inMem message * megad.0.p11_P11_long val=false, ack=true, ts=1441277647, from=system.adapter.megad.0, lc=1441277647 `
                                        Поправил. Установка через github, как сверху описано.

                                        1 Reply Last reply Reply Quote 0
                                        • B
                                          Bosya last edited by

                                          @Bluefox:

                                          Поправил. Установка через github, как сверху описано. `
                                          Спасибо, это заработало отлично.

                                          Есть следующая проблема. Для выходов ШИМ не правильно читаются данные. Если 0 то val=false, а если 1-255 то val = true.

                                          Приєтом команды:

                                          http://192.168.24.69/sec/?pt=12&cmd=get

                                          255 (ШИМ Р12 - 250, val=true)

                                          http://192.168.24.69/sec/?cmd=all

                                          ;;;;;;;temp:0/hum:0;;;ON;OFF/14;<color color="red">1;temp:25/hum:33;799;1023 (ШИМ р12 - 1, val=true)

                                          2015-09-09 10:37:08.053 - debug: megad.0 detected new value on port [12]: false

                                          2015-09-09 10:37:08.078 - debug: inMem message megad.0.* megad.0.p12_P12 val=false, ack=true, ts=1441784228, from=system.adapter.megad.0, lc=1441784228
                                          645____.png

                                          1 Reply Last reply Reply Quote 0
                                          • Bluefox
                                            Bluefox last edited by

                                            @Bosya:

                                            @Bluefox:

                                            Поправил. Установка через github, как сверху описано. `
                                            Спасибо, это заработало отлично.

                                            Есть следующая проблема. Для выходов ШИМ не правильно читаются данные. Если 0 то val=false, а если 1-255 то val = true.

                                            Приєтом команды:

                                            http://192.168.24.69/sec/?pt=12&cmd=get

                                            255 (ШИМ Р12 - 250, val=true)

                                            http://192.168.24.69/sec/?cmd=all

                                            ;;;;;;;temp:0/hum:0;;;ON;OFF/14;<color color="red">1;temp:25/hum:33;799;1023 (ШИМ р12 - 1, val=true)

                                            2015-09-09 10:37:08.053 - debug: megad.0 detected new value on port [12]: false

                                            2015-09-09 10:37:08.078 - debug: inMem message megad.0.* megad.0.p12_P12 val=false, ack=true, ts=1441784228, from=system.adapter.megad.0, lc=1441784228 `
                                            Поправил. Только значение скалируется от 0 до 1. Что бы получить значение как в меге надо указать фактор 256.

                                            Output 1 => 1 / 256 = 0.00390625

                                            А запись настроек в мегу работает?

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            829
                                            Online

                                            31.6k
                                            Users

                                            79.4k
                                            Topics

                                            1.3m
                                            Posts

                                            28
                                            430
                                            115448
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo