      Hi, was bedeutet dieser Fehler:


      javascript.0 2019-11-03 12:33:23.330 warn at process._tickCallback (internal/process/next_tick.js:68:7)
      javascript.0 2019-11-03 12:33:23.330 warn at Object.setInterval (script.js.Allgemein.Unifi:1731:38)
      javascript.0 2019-11-03 12:33:23.330 warn at workAP (script.js.Allgemein.Unifi:1360:6)
      javascript.0 2019-11-03 12:33:23.330 warn at setState (/opt/iobroker/node_modules/iobroker.javascript/lib/sandbox.js:1276:20)
      javascript.0 2019-11-03 12:33:23.330 warn You are assigning a undefined to the state "javascript.0.WLANUnifi.APInfo.AP-LR.Satisfaction" which expects a boolean. Please fix your code to use a boolean or change the state type to undefined. Thi

      Z 1 Reply Last reply Reply Quote 0
      • Z
        zahnheinrich @MyMeyer last edited by zahnheinrich

        @MyMeyer
        hat nix mit heatingcontrol zu tun oder?
        Sieht eher nach Unifi aus.
        Sehe auch keinen Fehler, nur Warnungen.

        M 1 Reply Last reply Reply Quote 0
        • M
          MyMeyer @zahnheinrich last edited by MyMeyer

          hat nix mit heatingcontrol zu tun oder?
          Sieht eher nach Unifi aus.

          Upps Falscher Bereich sollte zu "UniFi Script" kann es der Admin verschieben oder soll ich es löschen und neu erstellen ?
          Ich erstellen einen neuen Punkt im richtigen Bereich.zur Info. 🙂

          1 Reply Last reply Reply Quote 0
          • coyote
            coyote Most Active last edited by

            @Rene_HM ich habe noch eine Frage, was hat Vorrang Anwesenheit oder Zeitplan?
            Beispiel:

            Wohnung wird um 7 Uhr verlassen (programmierte Temperatur 22 Grad), Temperatur wird abgesenkt von 22 auf 21 Grad. Jetzt hätte ich aber gerne bevor ich nach Hause komme, dass die Temperatur um 13 Uhr wieder auf 22 Grad angehoben wird, obwohl ich abwesend bin. Hat die Zeit dann Vorrang?

            Rene_HM 1 Reply Last reply Reply Quote 0
            • Rene_HM
              Rene_HM Developer @coyote last edited by

              @coyote nein. wenn um 13:00 Uhr eine neue Periode beginnt und zu diesem Zeitpunkt "abwesend" noch gesetzt ist, wird zwar die neue Temperatur verwendet aber gleich auch abgesenkt. Erst wenn "abwesend" zurückgesetzt wird, wird die Absenkung aufgehoben...

              coyote 1 Reply Last reply Reply Quote 0
              • coyote
                coyote Most Active @Rene_HM last edited by

                @Rene_HM ok alles klar, das wollte ich wissen. Danke

                1 Reply Last reply Reply Quote 0
                • dirk1962
                  dirk1962 last edited by

                  Hi Rene,
                  erstmal vielen Dank für den Adapter, ich teste ihn seit gut einer Woche. Ich nutze Raspberrymatic mit HM und HMIP Thermostaten und Fensterkontakten. Es ist für jeden Raum eine Gruppe vom Typ Heizung angelegt und alle Geräte sind den richtigen Räumen und Gewerken zugeordnet. iobroker läuft auf einem PI4. Im ersten Schritt habe ich Instanz0 mit einem Profil und einer Periode angelegt. Als Funktion ist Heizung eingestellt, der Pfad zum Feiertag-Adapter ist angegeben, der Pfad für die Anwesenheit, Sensoren verwendet ist angehakt, Mo-So, Feiertage wie Sonntag und die vordefinierte Heizperiode ist angehakt. Die Instanz hat alle Räume erkannt und die entsprechenden Thermostate wurden auch zugeordnet. Die Sensoren musste ich händisch eintragen. In Instanz0 habe ich 4 Räume aktiviert und gespeichert. Danach habe ich Instanz1 angelegt, diese mit einem Profil und 5 Perioden und Mo-Fr und Sa-So. Als ich die Instanz geöffnet habe, waren die Einstellungen der ersten Instanz übernommen worden. Ich habe dann den Haken bei den 4 Räumen von Instanz0 entfernt und bei den restlichen Räumen den Haken gesetzt und gespeichert. In den Objekten wurden von beiden Instanzen alle Datenpunkte der entsprechenden Räume angelegt. Öffne ich dann aber wieder Instanz0, sind dort die Räume aus Instanz1 angehakt. Hier scheint noch ein Fehler im Adapter zu sein.
                  Im log kann man sehen, dass die Instanzen ca. alle 5 Minuten an die Thermostate senden, obwohl keine Änderung der Periode vorliegt. Dadurch geht der Duty Cycle der Raspberrymatic deutlich nach oben. Alle Thermostate stehen auf Manuell Mode. Habe ich hier eine Einstellung übersehen?

                  Rene_HM 1 Reply Last reply Reply Quote 0
                  • HomeZecke
                    HomeZecke last edited by

                    Bevor ich das auch mal probiere, ändert der Adapter die Profile in meinen Homematic Wandthermostaten direkt oder werden in IOBroker Profile angelegt die dann den Wandthermostat steuern?

                    Grüße..

                    H 1 Reply Last reply Reply Quote 0
                    • H
                      holgerwolf @HomeZecke last edited by

                      @HomeZecke sagte in Test Adapter HeatingControl v0.3.x:

                      Bevor ich das auch mal probiere, ändert der Adapter die Profile in meinen Homematic Wandthermostaten direkt oder werden in IOBroker Profile angelegt die dann den Wandthermostat steuern?

                      Grüße..

                      So isses...

                      1 Reply Last reply Reply Quote 0
                      • HomeZecke
                        HomeZecke last edited by

                        Hey, danke. "So isses..." sagt es mir immer noch nicht ganz Eindeutig. Aber ich tippe mal Du beziehst Dich damit auf ...werden in IOBroker Profile angelegt die dann den Wandthermostat steuern...

                        Grüße..

                        H 1 Reply Last reply Reply Quote 0
                        • H
                          holgerwolf @HomeZecke last edited by

                          @HomeZecke Sorry, hatte den richtigen Text "fett" hinterlegt: IOBroker Profile angelegt die dann den Wandthermostat steuern...

                          1 Reply Last reply Reply Quote 0
                          • HomeZecke
                            HomeZecke last edited by

                            Ah danke, habe ich jetzt gesehen... 👍

                            Grüße..

                            1 Reply Last reply Reply Quote 0
                            • A
                              AhleWurscht75 last edited by

                              @Rene_HM
                              Hallo, möchte nochmals eine weitere Frage stellen. Ist es möglich die händisch eingestellte Temperatur, also direkt am Thermostat eingestellt, bis zur nächsten Zeitperiode zu belassen? Aktuell stellt der Adapter diese nach kurzer Zeit, bzw. Prüfung auf die im Adapter eingestellte Temperatur zurück. Wunsch wäre quasi, dass diese Temperatur dann als "TemperaturOverride " erkannt wird?

                              Thx

                              Rene_HM 1 Reply Last reply Reply Quote 2
                              • M
                                Moskito last edited by Moskito

                                Hat sich erledigt!

                                1 Reply Last reply Reply Quote 0
                                • Rene_HM
                                  Rene_HM Developer @dirk1962 last edited by

                                  @dirk1962 Für den Support von mehr als einer Instanz habe ich ein issue in github angelegt. Das ist wirklich noch ein Fehler...
                                  https://github.com/rg-engineering/ioBroker.heatingcontrol/issues/49
                                  Bzgl. des Duty-cycles sollte die aktuelle Version zwar immer noch durch alle Räume gehen und bei jeder Änderung alles neu berechnen, gesendet werden sollte aber nur noch bei Änderung des Zielwertes. Das hatte ich in V0.3.1 eingebaut...

                                  rg-engineering created this issue in rg-engineering/ioBroker.heatingcontrol

                                  closed support von mehr als einer Instanz #49

                                  1 Reply Last reply Reply Quote 0
                                  • Rene_HM
                                    Rene_HM Developer @AhleWurscht75 last edited by Rene_HM

                                    @AhleWurscht75 Derzeit ist das so nicht vorgesehen, ist aber denkbar. Evtl mal ein issue im github anlegen? Ich schaue mir das an...

                                    coyote 1 Reply Last reply Reply Quote 0
                                    • coyote
                                      coyote Most Active @Rene_HM last edited by

                                      @Rene_HM hast du ne Idee warum das Profil nicht läuft? Es kommt ein Error im Log, ich weiß aber nicht warum. Eigentlich legt er ja die cron jobs an laut Log, aber warum kommt dann der Fehler: TypeError: Cannot read property 'val' of null
                                      Ich sehe keine Value die "null" ist.
                                      Laut Log müsste es " Profiles.0.Wohnung.Su-So.Periods.0.time" sein, da steht aber 07:00 drin.

                                      Profil ist Mo-Fr & Sa-So. Über die Woche ist alles einwandfrei gelaufen, nur heute morgen blieb es bei 21°C hängen.

                                      Log:

                                      heatingcontrol.0	2019-11-09 12:58:17.574	debug	(15109) system.adapter.admin.0: logging true
                                      heatingcontrol.0	2019-11-09 12:58:14.116	debug	(15109) ### all StateChange handled
                                      heatingcontrol.0	2019-11-09 12:58:14.116	debug	(15109) ### 111 handled
                                      heatingcontrol.0	2019-11-09 12:58:14.115	error	(15109) exception in CheckTemperatureChange [TypeError: Cannot read property 'val' of null]
                                      heatingcontrol.0	2019-11-09 12:58:14.114	debug	(15109) check ID Profiles.0.Wohnung.Su-So.Periods.0.time
                                      heatingcontrol.0	2019-11-09 12:58:14.114	debug	(15109) number of periods 2
                                      heatingcontrol.0	2019-11-09 12:58:14.114	debug	(15109) check room Wohnung
                                      heatingcontrol.0	2019-11-09 12:58:14.114	debug	(15109) profile 0
                                      heatingcontrol.0	2019-11-09 12:58:14.113	debug	(15109) get profile
                                      heatingcontrol.0	2019-11-09 12:58:14.112	debug	(15109) profile type 2
                                      heatingcontrol.0	2019-11-09 12:58:14.107	info	(15109) calculating new target temperatures
                                      heatingcontrol.0	2019-11-09 12:58:14.107	debug	(15109) [INFO] status = true next event: 9 Nov 2019 23:00:00
                                      heatingcontrol.0	2019-11-09 12:58:14.106	debug	(15109) [INFO] status = true next event: 10 Nov 2019 07:01:00
                                      heatingcontrol.0	2019-11-09 12:58:14.105	debug	(15109) [INFO] status = true next event: 11 Nov 2019 22:00:00
                                      heatingcontrol.0	2019-11-09 12:58:14.104	debug	(15109) [INFO] status = true next event: 11 Nov 2019 04:30:00
                                      heatingcontrol.0	2019-11-09 12:58:14.101	debug	(15109) create cron job #3 at 23:0 string: 0 0 23 * * 0,6 Europe/Berlin
                                      heatingcontrol.0	2019-11-09 12:58:14.100	debug	(15109) create cron job #2 at 7:1 string: 0 1 7 * * 0,6 Europe/Berlin
                                      heatingcontrol.0	2019-11-09 12:58:14.085	debug	(15109) create cron job #1 at 22:0 string: 0 0 22 * * 1-5 Europe/Berlin
                                      heatingcontrol.0	2019-11-09 12:58:14.083	debug	(15109) create cron job #0 at 4:30 string: 0 30 4 * * 1-5 Europe/Berlin
                                      heatingcontrol.0	2019-11-09 12:58:14.083	debug	(15109) push to list = 23,00
                                      heatingcontrol.0	2019-11-09 12:58:14.083	debug	(15109) ---2 found time for Wohnung at {"val":"23:00","ack":true,"ts":1573295415712,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1573031444308} 23:00
                                      heatingcontrol.0	2019-11-09 12:58:14.083	debug	(15109) push to list = 07,01
                                      heatingcontrol.0	2019-11-09 12:58:14.083	debug	(15109) ---2 found time for Wohnung at {"val":"07:01","ack":true,"ts":1573300694076,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1573300694069} 07:01
                                      heatingcontrol.0	2019-11-09 12:58:14.082	debug	(15109) setting Sa - Su
                                      heatingcontrol.0	2019-11-09 12:58:14.082	debug	(15109) push to list = 22,00
                                      heatingcontrol.0	2019-11-09 12:58:14.082	debug	(15109) ---1 found time for Wohnung at {"val":"22:00","ack":true,"ts":1573295469170,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1573032731757} 22:00
                                      heatingcontrol.0	2019-11-09 12:58:14.081	debug	(15109) push to list = 04,30
                                      heatingcontrol.0	2019-11-09 12:58:14.081	debug	(15109) ---1 found time for Wohnung at {"val":"04:30","ack":true,"ts":1573031345095,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1573031345086} 04:30
                                      heatingcontrol.0	2019-11-09 12:58:14.080	debug	(15109) ### state change already handled: 07:01 / 07:01 /// heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.time / heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.time
                                      heatingcontrol.0	2019-11-09 12:58:14.080	debug	(15109) ### handle state change heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.time {"val":"07:01","ack":true,"ts":1573300694076,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.use
                                      heatingcontrol.0	2019-11-09 12:58:14.079	debug	(15109) setting Mo - Fr
                                      heatingcontrol.0	2019-11-09 12:58:14.079	debug	(15109) profile 0
                                      heatingcontrol.0	2019-11-09 12:58:14.078	debug	(15109) get profile
                                      heatingcontrol.0	2019-11-09 12:58:14.078	debug	(15109) cron job stopped
                                      heatingcontrol.0	2019-11-09 12:58:14.078	debug	(15109) cron job stopped
                                      heatingcontrol.0	2019-11-09 12:58:14.077	debug	(15109) cron job stopped
                                      heatingcontrol.0	2019-11-09 12:58:14.077	debug	(15109) cron job stopped
                                      heatingcontrol.0	2019-11-09 12:58:14.077	debug	(15109) delete 4 cron jobs
                                      heatingcontrol.0	2019-11-09 12:58:14.077	debug	(15109) start CalculateNextTime, profile type 2
                                      heatingcontrol.0	2019-11-09 12:58:14.076	debug	(15109) ### state change already handled: 07:01 / 07:01 /// heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.time / heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.time
                                      heatingcontrol.0	2019-11-09 12:58:14.076	debug	(15109) ### handle state change heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.time {"val":"07:01","ack":true,"ts":1573300694073,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.use
                                      heatingcontrol.0	2019-11-09 12:58:14.073	debug	(15109) ### heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.time heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.Temperature 07:01 22.5
                                      heatingcontrol.0	2019-11-09 12:58:14.071	debug	(15109) ### handle state change heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.time {"val":"07:01","ack":false,"ts":1573300694069,"q":0,"from":"system.adapter.admin.0","user":"system.user.admin"
                                      heatingcontrol.0	2019-11-09 12:58:09.460	debug	(15109) ### all StateChange handled
                                      heatingcontrol.0	2019-11-09 12:58:09.460	debug	(15109) ### 111 handled
                                      heatingcontrol.0	2019-11-09 12:58:09.459	error	(15109) exception in CheckTemperatureChange [TypeError: Cannot read property 'val' of null]
                                      heatingcontrol.0	2019-11-09 12:58:09.459	debug	(15109) check ID Profiles.0.Wohnung.Su-So.Periods.0.time
                                      heatingcontrol.0	2019-11-09 12:58:09.458	debug	(15109) number of periods 2
                                      heatingcontrol.0	2019-11-09 12:58:09.458	debug	(15109) check room Wohnung
                                      heatingcontrol.0	2019-11-09 12:58:09.458	debug	(15109) profile 0
                                      heatingcontrol.0	2019-11-09 12:58:09.457	debug	(15109) get profile
                                      heatingcontrol.0	2019-11-09 12:58:09.457	debug	(15109) profile type 2
                                      heatingcontrol.0	2019-11-09 12:58:09.447	debug	(15109) ### state change already handled: 22.5 / 22.5 /// heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.Temperature / heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.Temperature
                                      heatingcontrol.0	2019-11-09 12:58:09.447	debug	(15109) ### handle state change heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.Temperature {"val":22.5,"ack":true,"ts":1573300689443,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system
                                      heatingcontrol.0	2019-11-09 12:58:09.444	info	(15109) calculating new target temperatures
                                      heatingcontrol.0	2019-11-09 12:58:09.444	debug	(15109) ### heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.Temperature heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.time 22.5 07:00
                                      heatingcontrol.0	2019-11-09 12:58:09.440	debug	(15109) ### handle state change heatingcontrol.0.Profiles.0.Wohnung.Sa-So.Periods.0.Temperature {"val":22.5,"ack":false,"ts":1573300689439,"q":0,"from":"system.adapter.admin.0","user":"system.user.ad
                                      
                                      1 Reply Last reply Reply Quote 0
                                      • V
                                        vogtländer last edited by

                                        Hallo erstmal Danke für den super Adapter.
                                        Ich habe seit gestern das Problem, das ich die folgende Fehlermeldung erhalte.
                                        heatingcontrol.0 2019-11-09 13:02:59.797 error exception in CheckTemperatureChange [TypeError: Cannot read property 'val' of null]

                                        Vielleicht kann mir jemand helfen. Es liegt bestimmt an den Einstellungen. aber ich komme nicht dahinter

                                        heatingcontrol.0	2019-11-09 13:02:59.797	error	exception in CheckTemperatureChange [TypeError: Cannot read property 'val' of null]
                                        heatingcontrol.0	2019-11-09 13:02:59.791	debug	check ID Profiles.0.Küche HK.Su-So.Periods.0.time
                                        heatingcontrol.0	2019-11-09 13:02:59.791	debug	number of periods 4
                                        heatingcontrol.0	2019-11-09 13:02:59.791	debug	check room Küche HK
                                        heatingcontrol.0	2019-11-09 13:02:59.790	debug	profile 0
                                        heatingcontrol.0	2019-11-09 13:02:59.782	debug	get profile
                                        heatingcontrol.0	2019-11-09 13:02:59.781	debug	profile type 2
                                        heatingcontrol.0	2019-11-09 13:02:59.733	info	calculating new target temperatures
                                        heatingcontrol.0	2019-11-09 13:02:59.733	debug	[INFO] status = true next event: 9 Nov 2019 16:00:00
                                        heatingcontrol.0	2019-11-09 13:02:59.732	debug	[INFO] status = true next event: 10 Nov 2019 11:00:00
                                        heatingcontrol.0	2019-11-09 13:02:59.732	debug	[INFO] status = true next event: 10 Nov 2019 09:00:00
                                        heatingcontrol.0	2019-11-09 13:02:59.732	debug	[INFO] status = true next event: 10 Nov 2019 05:00:00
                                        heatingcontrol.0	2019-11-09 13:02:59.732	debug	[INFO] status = true next event: 11 Nov 2019 16:00:00
                                        heatingcontrol.0	2019-11-09 13:02:59.731	debug	[INFO] status = true next event: 11 Nov 2019 12:00:00
                                        heatingcontrol.0	2019-11-09 13:02:59.731	debug	[INFO] status = true next event: 11 Nov 2019 07:00:00
                                        heatingcontrol.0	2019-11-09 13:02:59.731	debug	[INFO] status = true next event: 11 Nov 2019 05:00:00
                                        heatingcontrol.0	2019-11-09 13:02:59.731	debug	create cron job #7 at 16:0 string: 0 0 16 * * 0,6 Europe/Berlin
                                        heatingcontrol.0	2019-11-09 13:02:59.730	debug	create cron job #6 at 11:0 string: 0 0 11 * * 0,6 Europe/Berlin
                                        heatingcontrol.0	2019-11-09 13:02:59.730	debug	create cron job #5 at 9:0 string: 0 0 9 * * 0,6 Europe/Berlin
                                        heatingcontrol.0	2019-11-09 13:02:59.730	debug	create cron job #4 at 5:0 string: 0 0 5 * * 0,6 Europe/Berlin
                                        heatingcontrol.0	2019-11-09 13:02:59.729	debug	create cron job #3 at 16:0 string: 0 0 16 * * 1-5 Europe/Berlin
                                        heatingcontrol.0	2019-11-09 13:02:59.729	debug	create cron job #2 at 12:0 string: 0 0 12 * * 1-5 Europe/Berlin
                                        heatingcontrol.0	2019-11-09 13:02:59.729	debug	create cron job #1 at 7:0 string: 0 0 7 * * 1-5 Europe/Berlin
                                        heatingcontrol.0	2019-11-09 13:02:59.728	debug	create cron job #0 at 5:0 string: 0 0 5 * * 1-5 Europe/Berlin
                                        
                                        1 Reply Last reply Reply Quote 0
                                        • coyote
                                          coyote Most Active last edited by

                                          @Rene_HM Update auf die 0.3.4 gemacht, jetzt geht es wieder, wobei ich jetzt nicht weiß, ob es nach einem Neustart des Adapters auch wieder funktioniert hätte, weil so wie es aussieht, hast du von 0.3.3 auf 0.3.4 nicht viel geändert oder?

                                          @vogtländer gleicher Fehler wie bei mir, kannst du mal einfach den Adapter neu starten, ob dann der Fehler weg ist?

                                          Rene_HM 1 Reply Last reply Reply Quote 0
                                          • V
                                            vogtländer last edited by

                                            @coyote said in Test Adapter HeatingControl v0.3.x:

                                            @Rene_HM

                                            Hallo,
                                            ich habe aktuell die Version 0.3.3. Ich würde gern das Update machen aber aktuell wird mir nur diese
                                            Version angezeigt.

                                            coyote 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            633
                                            Online

                                            31.6k
                                            Users

                                            79.5k
                                            Topics

                                            1.3m
                                            Posts

                                            heating
                                            236
                                            3157
                                            1483776
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo