    Zigbee Adapter mit neuem Converter

    This topic has been deleted. Only users with topic management privileges can see it.
    • MathiasJ
      MathiasJ @Asgothian last edited by

      @Asgothian
      also, Du willst mir jetzt erzählen, dass man die CC2538+CC2592 PA-Zigbee-Funkmodul nur einstecken muß, dann funktionieren die auch?
      Du hast recht. es geht um den Adapter. Aber ohne einer Firmware werden die CC2538+CC2592 PA-Zigbee-Funkmodule auch auf diesem Adapter nicht laufen.

      arteck Asgothian 2 Replies Last reply Reply Quote -1
      • arteck
        arteck Developer Most Active @MathiasJ last edited by arteck

        auf die gefahr das ich gleich auf den deckel von einem Admin bekomme

        @MathiasJ lesen kannst du aber schon .. oder..
        https://forum.iobroker.net/topic/24972/wie-ersetzte-ich-den-cc2531-cc2530/31

        also bitte immer das ganze sehen..und lesen.. nicht nur zwischen den Zeilen

        MathiasJ 1 Reply Last reply Reply Quote 0
        • Asgothian
          Asgothian Developer @MathiasJ last edited by

          @MathiasJ sagte in Zigbee Adapter mit neuem Converter:

          @Asgothian
          also, Du willst mir jetzt erzählen, dass man die CC2538+CC2592 PA-Zigbee-Funkmodul nur einstecken muß, dann funktionieren die auch?

          Ich will dir erzählen das du zumindest mal erwähnen musst um welche Hardware es geht. In deinem Post stand nichts von dem Stick, und dieser Thread handelt (laut Titel und 90% der posts) vom neuen Adapter, nicht von irgendwelcher Hardware.

          Gedanken lesen kann ich nicht - woher soll ich also wissen das du den CC2538+CC2592 meinst ?

          Du musst deine Fragen schon vollständig stellen.

          1 Reply Last reply Reply Quote 0
          • S
            schienw last edited by

            Hallo,
            habe seit ein paar Tagen den zigbee-Adapter erfolgreich mit einer Lampe, Repeater und Schalter am Laufen. Hab gestern mit den Gruppen herumgespielt und seitdem sind unter Geräte keine Geräte mehr sichtbar.
            ae6c4b16-dc68-461a-a8b0-4eb0920a3ee3-image.png
            d4a0b9ac-3a53-4d63-9bb1-d22d62db9196-image.png

            Habe jetzt auf diese, aktuelle Version upgedatet und sehe leider die Geräte auch nicht.
            Habe aber unter Objecte alle Geräte sichtbar.

            2a5ad83a-f868-4d2b-9eb8-746ef736e0e7-image.png
            Hat jemand eine Idee?

            Danke

            Asgothian arteck 2 Replies Last reply Reply Quote 0
            • Asgothian
              Asgothian Developer @schienw last edited by

              @schienw
              Bitte prüf mal ob es im Log einträge gibt. Die fehlende Darstellung bei den Kacheln ist zumeist auf ein Problem mit den Gruppeninfos zurück zu führen.

              Du müsstest also im Log warn oder Fehlermeldungen bekommen wenn du die Adapterkonfiguration öffnest.

              A.

              1 Reply Last reply Reply Quote 0
              • arteck
                arteck Developer Most Active @schienw last edited by arteck

                @schienw evtl. mit dev tools (PF12) schauen wo es zu fehler kommt..

                1 Reply Last reply Reply Quote 0
                • S
                  schienw last edited by

                  Danke,

                  bekomme nur diesen Error:
                  States redis pmessage zigbee.0.*/zigbee.0.info.pairingMessage:{"val":"Error: Failed to execute LQI for '0x086bd7fffe21b535'. "Error: AREQ - ZDO - mgmtLqiRsp after 10000ms\n at Timeout.obj

                  Gruß

                  WS

                  1 Reply Last reply Reply Quote 0
                  • S
                    schienw last edited by

                    und das hier:
                    zigbee.0 2019-11-28 10:05:40.887 debug (28601) shouldConfigure? 0x086bd7fffe21b535 TRADFRI bulb E14 W op/ch 400lm
                    zigbee.0 2019-11-28 10:05:40.886 debug (28601) shouldConfigure? 0x000d6ffffe9cbfcf TRADFRI signal repeater

                    Asgothian 1 Reply Last reply Reply Quote 0
                    • Asgothian
                      Asgothian Developer @schienw last edited by

                      @schienw
                      Beides sind bekannte Meldungen die mit dem Problem nichts zu tun haben. Kannst du bitte genau beschreiben was du getan hast bevor die objektanzeige weg blieb, dann kann ich versuchen das nachzustellen - aber erst heute Abend.

                      A.

                      1 Reply Last reply Reply Quote 0
                      • S
                        schienw last edited by

                        ok, danke.
                        ich hatte diese Meldungen:
                        2019-11-27 20:35:29.523 - error: zigbee.0 (7485) getDevices group info error: {} - {"val":"","ack":false,"ts":1574882933507,"q":0,"from":"system.adapter.admin.0","user":"system.user.admin","lc":1574882933507}
                        2019-11-27 20:35:30.460 - error: zigbee.0 (7485) getDevices group info error: {} - {"val":"","ack":false,"ts":1574882933507,"q":0,"from":"system.adapter.admin.0","user":"system.user.admin","lc":1574882933507}
                        2019-11-27 20:35:30.517 - error: zigbee.0 (7485) getDevices group info error: {} - {"val":"","ack":false,"ts":1574882933507,"q":0,"from":"system.adapter.admin.0","user":"system.user.admin","lc":1574882933507}
                        2019-11-27 20:35:30.950 - error: zigbee.0 (7485) getDevices group info error: {} - {"val":"","ack":false,"ts":1574882933507,"q":0,"from":"system.adapter.admin.0","user":"system.user.admin","lc":1574882933507}
                        2019-11

                        Darauf habe ich unter Objecte in group meine Gruppe 1 eingetragen und seitdem habe ich den Fehler.

                        Gruß

                        WS

                        1 Reply Last reply Reply Quote 0
                        • a200
                          a200 last edited by

                          Wie installiere ich den Adapter? habe bis jetzt folgendes gemacht:

                          cd /opt/iobroker
                          iobroker stop
                          cd node_modules/
                          rm -fr iobroker.zigbee
                          tar xfvz /home/pi/ioBroker-ioBroker.zigbee-ddfb265.tar.gz
                          cd /opt/iobroker
                          iobroker start
                          

                          Ist das korrekt. Denn ich erhalte nur Fehermeldungen:

                          host.pi-broker	2019-11-28 14:05:34.689	error	instance system.adapter.zigbee.0 terminated with code 1 (JS_CONTROLLER_STOPPED)
                          host.pi-broker	2019-11-28 14:05:34.689	error	Caught by controller[0]: at Function.Module._load (module.js:498:3)
                          host.pi-broker	2019-11-28 14:05:34.688	error	Caught by controller[0]: at tryModuleLoad (module.js:506:12)
                          host.pi-broker	2019-11-28 14:05:34.687	error	Caught by controller[0]: at Module.load (module.js:566:32)
                          host.pi-broker	2019-11-28 14:05:34.687	error	Caught by controller[0]: at Object.Module._extensions..js (module.js:664:10)
                          host.pi-broker	2019-11-28 14:05:34.686	error	Caught by controller[0]: at Module._compile (module.js:653:30)
                          host.pi-broker	2019-11-28 14:05:34.686	error	Caught by controller[0]: at Object.<anonymous> (/opt/iobroker/node_modules/iobroker.zigbee/lib/seriallist.js:3:25)
                          host.pi-broker	2019-11-28 14:05:34.685	error	Caught by controller[0]: at require (internal/module.js:11:18)
                          host.pi-broker	2019-11-28 14:05:34.685	error	Caught by controller[0]: at Module.require (module.js:597:17)
                          host.pi-broker	2019-11-28 14:05:34.684	error	Caught by controller[0]: at Function.Module._load (module.js:475:25)
                          host.pi-broker	2019-11-28 14:05:34.684	error	Caught by controller[0]: at Function.Module._resolveFilename (module.js:548:15)
                          host.pi-broker	2019-11-28 14:05:34.683	error	Caught by controller[0]: Error: Cannot find module 'zigbee-herdsman/dist/adapter/serialPortUtils'
                          host.pi-broker	2019-11-28 14:05:34.683	error	Caught by controller[0]: ^
                          host.pi-broker	2019-11-28 14:05:34.682	error	Caught by controller[0]: throw err;
                          host.pi-broker	2019-11-28 14:05:34.681	error	Caught by controller[0]: module.js:550
                          

                          Was mache ich falsch.

                          ps. nutze CC2538+CC2592 als Hardware

                          1 Reply Last reply Reply Quote 0
                          • D
                            dimaiv last edited by dimaiv

                            Ich habe gerade so gemacht wie oben beschrien ist und hat sofort funktioniert. Einfach so wie beim updaten, über die Katze im Admin auf Beliebig gehen, url eingeben, fertig.
                            Stick rein comPort eingeben, neue Gerät pairen. Pairen war auch in Sekunden fertig.

                            Beim url kopieren und eingeben am ende Leerzeichen löschen !

                            a200 1 Reply Last reply Reply Quote 0
                            • a200
                              a200 @dimaiv last edited by

                              @dimaiv sagte in Zigbee Adapter mit neuem Converter:

                              Beim url kopieren und eingeben am ende Leerzeichen löschen !

                              Ich Depp!!!

                              1 Reply Last reply Reply Quote 0
                              • T
                                Tictactoo last edited by

                                Ich weiß nicht, ob ich damit hier jetzt an der richtigen Stelle bin, aber besteht vielleicht die Möglichkeit einzubauen in den Adapter, dass man die vorhandenen Geräte nach Hersteller oder Name sortiert?

                                Asgothian 1 Reply Last reply Reply Quote 0
                                • Asgothian
                                  Asgothian Developer @Tictactoo last edited by Asgothian

                                  @Tictactoo sagte in Zigbee Adapter mit neuem Converter:

                                  Ich weiß nicht, ob ich damit hier jetzt an der richtigen Stelle bin, aber besteht vielleicht die Möglichkeit einzubauen in den Adapter, dass man die vorhandenen Geräte nach Hersteller oder Name sortiert?

                                  Du bist hier an der falschen Stelle. Nachdem das gesagt hat ein paar Punkte zu der Frage. Ein Umsortieren nach Hersteller

                                  • setzt voraus das diese Information immer korrekt gefüllt ist - das ist sie nicht.
                                  • würde zwei Ebenen vor die eigentliche ID des Gerätes setzen (Bsp: zigbee.0.90fd9ffffe6de22b wird zu zigbee.0.Ikea.TRADFRI transformer 10W.90fd9ffffe6de22)
                                  • würde entweder die Möglichkeit zum Umbenennen der Geräte entfernen oder das Umbenennen der Geräte würde die Adresse im Objektbaum ändern, da der Name teil der Adresse ist.

                                  Ich denke es gibt noch mehr Gründe die dagegen sprechen - rechne also nicht damit das dieser Wunsch umgesetzt wird.

                                  T 1 Reply Last reply Reply Quote 0
                                  • S
                                    Schrauberheld last edited by Schrauberheld

                                    Das Problem mit "Currently no devices" hatte ich nach dem Update auch.
                                    Ohne die Geräteliste zu verändern hab ich die Geräte in den pairing modus versetzt und nach dem neuen pairing war das Problem behoben.

                                    Nur beim Sonoff Schalter gibts noch Probleme. Aber die hatte ich auch schon vorher. Grade beim Re-Pairing will der Sonoff wohl nicht so.

                                    Ich hab jetzt den Sonoff aus der Liste entfernt aber besser wirds davon auch nicht.
                                    @Asgothian + @arteck
                                    Folgendes habe ich nach dem Löschen im Log beobachtet:

                                    2019-11-28 19:31:46.417 - debug: zigbee.0 (774) deleteDevice message: {"id":"zigbee.0.00124b001f6695ce"}
                                    2019-11-28 19:31:46.419 - debug: zigbee.0 (774) deleteDevice sysid: 0x00124b001f6695ce
                                    2019-11-28 19:31:46.430 - debug: zigbee.0 (774) Remove successful.
                                    2019-11-28 19:31:46.433 - debug: zigbee.0 (774) Successfully removed from shepherd!
                                    2019-11-28 19:31:46.896 - debug: zigbee.0 (774) sendTo "deleteDevice" to system.adapter.admin.0 from system.adapter.zigbee.0
                                    

                                    Danach den Sonoff zurückgesetzt, pairing will er dann automatisch.
                                    Aber anscheinend gibt es da keine Kommunikation.
                                    Statt dessen sehe ich im Log

                                    2019-11-28 19:32:16.369 - debug: zigbee.0 (774) Successfully pinged 0x00124b001f6695ce undefined
                                    
                                    

                                    Und bei GetMap

                                    {"parent":"0x00124b0018ed16e2","networkAddress":56014,"ieeeAddr":"0x00124b001f6695ce","lqi":0,"relationship":3,"depth":255},
                                    

                                    Kann ich über die Konsole den Traffic im Zigbee Netz sniffen oder sowas?
                                    Debug ausgabe im Log liefert da leider nichts.

                                    Edit:
                                    Hab noch einen weiteren Sonoff Basic ZBR1 mit dem hatte ich vor einigen Tagen auch das Problem dass er sich nicht Koppeln ließ. Der hat nun einige Tage ohne Netzanschluss in seinem Karton verbracht und nun lässt er sich wieder Koppeln.
                                    Es scheint hier also ein Problem mit dem Zigbee Modul zu geben.
                                    Ich konnte dem ganzen aber noch ein paar Fehlermeldungen entlocken:

                                    2019-11-28 20:16:02.586 - debug: zigbee.0 (774) handleDeviceJoined. {"device":{"ID":13,"ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_endpoints":[],"_interviewCompleted":false,"_interviewing":false,"meta":{},"_lastSeen":null}}
                                    2019-11-28 20:16:02.592 - debug: zigbee.0 (774) handleDeviceInterview. {"status":"started","device":{"ID":13,"ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_endpoints":[],"_interviewCompleted":false,"_interviewing":false,"meta":{},"_lastSeen":1574968562588}}
                                    2019-11-28 20:16:02.608 - info: zigbee.0 (774) Starting interview of '0x00124b001f6695ce'
                                    2019-11-28 20:16:02.863 - debug: zigbee.0 (774) handleDeviceAnnounce. {"device":{"ID":13,"ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_endpoints":[],"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968562861}}
                                    2019-11-28 20:16:02.864 - debug: zigbee.0 (774) Device '0x00124b001f6695ce' announced itself
                                    2019-11-28 20:16:03.541 - debug: zigbee.0 (774) handleMessage. {"type":"attributeReport","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"inputClusters":[],"outputClusters":[],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}}},"_binds":[]}],"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968563540},"endpoint":"[Circular]","data":{"onOff":0},"linkquality":47,"groupID":0,"cluster":"genOnOff"}
                                    2019-11-28 20:16:03.544 - debug: zigbee.0 (774) Received Zigbee message from '0x00124b001f6695ce', type 'attributeReport', cluster 'genOnOff', data '{"onOff":0}' from endpoint 1 with groupID 0
                                    2019-11-28 20:16:03.546 - debug: zigbee.0 (774) Type attributeReport device {"type":"device","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"inputClusters":[],"outputClusters":[],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}}},"_binds":[]}],"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968563540},"mapped":null,"name":"0x00124b001f6695ce"} incoming event: {"type":"attributeReport","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"inputClusters":[],"outputClusters":[],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}}},"_binds":[]}],"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968563540},"endpoint":"[Circular]","data":{"onOff":0},"linkquality":47,"groupID":0,"cluster":"genOnOff"}
                                    2019-11-28 20:16:03.559 - debug: zigbee.0 (774) handleMessage. {"type":"attributeReport","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"inputClusters":[],"outputClusters":[],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}}},"_binds":[]}],"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968563557},"endpoint":"[Circular]","data":{"onOff":0},"linkquality":47,"groupID":0,"cluster":"genOnOff"}
                                    2019-11-28 20:16:03.565 - debug: zigbee.0 (774) handleMessage. {"type":"attributeReport","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"inputClusters":[],"outputClusters":[],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}}},"_binds":[]}],"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968563564},"endpoint":"[Circular]","data":{"onOff":0},"linkquality":47,"groupID":0,"cluster":"genOnOff"}
                                    2019-11-28 20:16:03.569 - debug: zigbee.0 (774) handleMessage. {"type":"attributeReport","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"inputClusters":[],"outputClusters":[],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}}},"_binds":[]}],"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968563568},"endpoint":"[Circular]","data":{"onOff":0},"linkquality":47,"groupID":0,"cluster":"genOnOff"}
                                    2019-11-28 20:16:03.576 - debug: zigbee.0 (774) Received Zigbee message from '0x00124b001f6695ce', type 'attributeReport', cluster 'genOnOff', data '{"onOff":0}' from endpoint 1 with groupID 0
                                    2019-11-28 20:16:03.578 - debug: zigbee.0 (774) Type attributeReport device {"type":"device","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"inputClusters":[],"outputClusters":[],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}}},"_binds":[]}],"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968563568},"mapped":null,"name":"0x00124b001f6695ce"} incoming event: {"type":"attributeReport","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"inputClusters":[],"outputClusters":[],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}}},"_binds":[]}],"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968563568},"endpoint":"[Circular]","data":{"onOff":0},"linkquality":47,"groupID":0,"cluster":"genOnOff"}
                                    2019-11-28 20:16:03.580 - debug: zigbee.0 (774) Received Zigbee message from '0x00124b001f6695ce', type 'attributeReport', cluster 'genOnOff', data '{"onOff":0}' from endpoint 1 with groupID 0
                                    2019-11-28 20:16:03.581 - debug: zigbee.0 (774) Type attributeReport device {"type":"device","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"inputClusters":[],"outputClusters":[],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}}},"_binds":[]}],"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968563568},"mapped":null,"name":"0x00124b001f6695ce"} incoming event: {"type":"attributeReport","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"inputClusters":[],"outputClusters":[],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}}},"_binds":[]}],"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968563568},"endpoint":"[Circular]","data":{"onOff":0},"linkquality":47,"groupID":0,"cluster":"genOnOff"}
                                    2019-11-28 20:16:03.583 - debug: zigbee.0 (774) Received Zigbee message from '0x00124b001f6695ce', type 'attributeReport', cluster 'genOnOff', data '{"onOff":0}' from endpoint 1 with groupID 0
                                    2019-11-28 20:16:03.584 - debug: zigbee.0 (774) Type attributeReport device {"type":"device","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"inputClusters":[],"outputClusters":[],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}}},"_binds":[]}],"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968563568},"mapped":null,"name":"0x00124b001f6695ce"} incoming event: {"type":"attributeReport","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"inputClusters":[],"outputClusters":[],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}}},"_binds":[]}],"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968563568},"endpoint":"[Circular]","data":{"onOff":0},"linkquality":47,"groupID":0,"cluster":"genOnOff"}
                                    2019-11-28 20:16:04.833 - debug: zigbee.0 (774) handleMessage. {"type":"readResponse","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"profileID":260,"deviceID":9,"inputClusters":[0,3,4,5,6],"outputClusters":[0],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}},"genBasic":{"attributes":{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1}}},"_binds":[]}],"_manufacturerName":"SONOFF","_powerSource":"Mains (single phase)","_modelID":"BASICZBR3","_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968564830},"endpoint":"[Circular]","data":{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1},"linkquality":47,"groupID":0,"cluster":"genBasic"}
                                    2019-11-28 20:16:04.835 - debug: zigbee.0 (774) Received Zigbee message from '0x00124b001f6695ce', type 'readResponse', cluster 'genBasic', data '{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1}' from endpoint 1 with groupID 0
                                    2019-11-28 20:16:04.837 - debug: zigbee.0 (774) Type readResponse device {"type":"device","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"profileID":260,"deviceID":9,"inputClusters":[0,3,4,5,6],"outputClusters":[0],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}},"genBasic":{"attributes":{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1}}},"_binds":[]}],"_manufacturerName":"SONOFF","_powerSource":"Mains (single phase)","_modelID":"BASICZBR3","_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968564830},"mapped":{"zigbeeModel":["BASICZBR3"],"model":"BASICZBR3","vendor":"SONOFF","description":"Zigbee smart switch","supports":"on/off","fromZigbee":[{"cluster":"genOnOff","type":["attributeReport","readResponse"]}],"toZigbee":[{"key":["state"]}]},"name":"0x00124b001f6695ce"} incoming event: {"type":"readResponse","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"profileID":260,"deviceID":9,"inputClusters":[0,3,4,5,6],"outputClusters":[0],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}},"genBasic":{"attributes":{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1}}},"_binds":[]}],"_manufacturerName":"SONOFF","_powerSource":"Mains (single phase)","_modelID":"BASICZBR3","_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968564830},"endpoint":"[Circular]","data":{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1},"linkquality":47,"groupID":0,"cluster":"genBasic"}
                                    2019-11-28 20:16:04.864 - debug: zigbee.0 (774) Wrong device 00124b001f6695ce
                                    2019-11-28 20:16:05.322 - debug: zigbee.0 (774) handleMessage. {"type":"readResponse","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"profileID":260,"deviceID":9,"inputClusters":[0,3,4,5,6],"outputClusters":[0],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}},"genBasic":{"attributes":{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1,"zclVersion":1}}},"_binds":[]}],"_manufacturerName":"SONOFF","_powerSource":"Mains (single phase)","_modelID":"BASICZBR3","_zclVersion":1,"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968565316},"endpoint":"[Circular]","data":{"zclVersion":1},"linkquality":47,"groupID":0,"cluster":"genBasic"}
                                    2019-11-28 20:16:05.325 - debug: zigbee.0 (774) Received Zigbee message from '0x00124b001f6695ce', type 'readResponse', cluster 'genBasic', data '{"zclVersion":1}' from endpoint 1 with groupID 0
                                    2019-11-28 20:16:05.328 - debug: zigbee.0 (774) Type readResponse device {"type":"device","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"profileID":260,"deviceID":9,"inputClusters":[0,3,4,5,6],"outputClusters":[0],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}},"genBasic":{"attributes":{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1,"zclVersion":1}}},"_binds":[]}],"_manufacturerName":"SONOFF","_powerSource":"Mains (single phase)","_modelID":"BASICZBR3","_zclVersion":1,"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968565316},"mapped":{"zigbeeModel":["BASICZBR3"],"model":"BASICZBR3","vendor":"SONOFF","description":"Zigbee smart switch","supports":"on/off","fromZigbee":[{"cluster":"genOnOff","type":["attributeReport","readResponse"]}],"toZigbee":[{"key":["state"]}]},"name":"0x00124b001f6695ce"} incoming event: {"type":"readResponse","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"profileID":260,"deviceID":9,"inputClusters":[0,3,4,5,6],"outputClusters":[0],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}},"genBasic":{"attributes":{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1,"zclVersion":1}}},"_binds":[]}],"_manufacturerName":"SONOFF","_powerSource":"Mains (single phase)","_modelID":"BASICZBR3","_zclVersion":1,"_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968565316},"endpoint":"[Circular]","data":{"zclVersion":1},"linkquality":47,"groupID":0,"cluster":"genBasic"}
                                    2019-11-28 20:16:05.355 - debug: zigbee.0 (774) Wrong device 00124b001f6695ce
                                    2019-11-28 20:16:05.449 - debug: zigbee.0 (774) handleMessage. {"type":"readResponse","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"profileID":260,"deviceID":9,"inputClusters":[0,3,4,5,6],"outputClusters":[0],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}},"genBasic":{"attributes":{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1,"zclVersion":1,"hwVersion":1,"dateCode":"20190907-V102"}}},"_binds":[]}],"_manufacturerName":"SONOFF","_powerSource":"Mains (single phase)","_modelID":"BASICZBR3","_zclVersion":1,"_hardwareVersion":1,"_dateCode":"20190907-V102","_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968565445},"endpoint":"[Circular]","data":{"hwVersion":1,"dateCode":"20190907-V102"},"linkquality":47,"groupID":0,"cluster":"genBasic"}
                                    2019-11-28 20:16:05.455 - debug: zigbee.0 (774) Received Zigbee message from '0x00124b001f6695ce', type 'readResponse', cluster 'genBasic', data '{"hwVersion":1,"dateCode":"20190907-V102"}' from endpoint 1 with groupID 0
                                    2019-11-28 20:16:05.458 - debug: zigbee.0 (774) Type readResponse device {"type":"device","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"profileID":260,"deviceID":9,"inputClusters":[0,3,4,5,6],"outputClusters":[0],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}},"genBasic":{"attributes":{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1,"zclVersion":1,"hwVersion":1,"dateCode":"20190907-V102"}}},"_binds":[]}],"_manufacturerName":"SONOFF","_powerSource":"Mains (single phase)","_modelID":"BASICZBR3","_zclVersion":1,"_hardwareVersion":1,"_dateCode":"20190907-V102","_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968565445},"mapped":{"zigbeeModel":["BASICZBR3"],"model":"BASICZBR3","vendor":"SONOFF","description":"Zigbee smart switch","supports":"on/off","fromZigbee":[{"cluster":"genOnOff","type":["attributeReport","readResponse"]}],"toZigbee":[{"key":["state"]}]},"name":"0x00124b001f6695ce"} incoming event: {"type":"readResponse","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"profileID":260,"deviceID":9,"inputClusters":[0,3,4,5,6],"outputClusters":[0],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}},"genBasic":{"attributes":{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1,"zclVersion":1,"hwVersion":1,"dateCode":"20190907-V102"}}},"_binds":[]}],"_manufacturerName":"SONOFF","_powerSource":"Mains (single phase)","_modelID":"BASICZBR3","_zclVersion":1,"_hardwareVersion":1,"_dateCode":"20190907-V102","_interviewCompleted":false,"_interviewing":true,"meta":{},"_lastSeen":1574968565445},"endpoint":"[Circular]","data":{"hwVersion":1,"dateCode":"20190907-V102"},"linkquality":47,"groupID":0,"cluster":"genBasic"}
                                    2019-11-28 20:16:05.477 - debug: zigbee.0 (774) handleDeviceInterview. {"status":"successful","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"profileID":260,"deviceID":9,"inputClusters":[0,3,4,5,6],"outputClusters":[0],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}},"genBasic":{"attributes":{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1,"zclVersion":1,"hwVersion":1,"dateCode":"20190907-V102"}}},"_binds":[]}],"_manufacturerName":"SONOFF","_powerSource":"Mains (single phase)","_modelID":"BASICZBR3","_zclVersion":1,"_hardwareVersion":1,"_dateCode":"20190907-V102","_interviewCompleted":true,"_interviewing":false,"meta":{},"_lastSeen":1574968565445}}
                                    2019-11-28 20:16:05.479 - info: zigbee.0 (774) Successfully interviewed '0x00124b001f6695ce', device has succesfully been paired
                                    2019-11-28 20:16:05.481 - info: zigbee.0 (774) Device '0x00124b001f6695ce' is supported, identified as: SONOFF Zigbee smart switch (BASICZBR3)
                                    2019-11-28 20:16:05.494 - debug: zigbee.0 (774) New device event: {"type":"device","device":{"ID":13,"_type":"Router","ieeeAddr":"0x00124b001f6695ce","_networkAddress":12616,"_manufacturerID":0,"_endpoints":[{"ID":1,"profileID":260,"deviceID":9,"inputClusters":[0,3,4,5,6],"outputClusters":[0],"deviceNetworkAddress":12616,"deviceIeeeAddress":"0x00124b001f6695ce","clusters":{"genOnOff":{"attributes":{"onOff":0}},"genBasic":{"attributes":{"modelId":"BASICZBR3","manufacturerName":"SONOFF","powerSource":1,"zclVersion":1,"hwVersion":1,"dateCode":"20190907-V102"}}},"_binds":[]}],"_manufacturerName":"SONOFF","_powerSource":"Mains (single phase)","_modelID":"BASICZBR3","_zclVersion":1,"_hardwareVersion":1,"_dateCode":"20190907-V102","_interviewCompleted":true,"_interviewing":false,"meta":{},"_lastSeen":1574968565445},"mapped":{"zigbeeModel":["BASICZBR3"],"model":"BASICZBR3","vendor":"SONOFF","description":"Zigbee smart switch","supports":"on/off","fromZigbee":[{"cluster":"genOnOff","type":["attributeReport","readResponse"]}],"toZigbee":[{"key":["state"]}]},"name":"0x00124b001f6695ce"}
                                    2019-11-28 20:16:05.496 - debug: zigbee.0 (774) new devive 0x00124b001f6695ce 12616 BASICZBR3
                                    2019-11-28 20:16:05.509 - debug: zigbee.0 (774) Wrong device 00124b001f6695ce
                                    
                                    1 Reply Last reply Reply Quote 0
                                    • arteck
                                      arteck Developer Most Active last edited by

                                      @Asgothian hat die Abschaltung der LED realisiert.. sollte laufen

                                      Kalle Blomquist 1 Reply Last reply Reply Quote 1
                                      • ?
                                        A Former User last edited by

                                        Habe gestern den CC2538 von @dimaiv bekommen.
                                        Der erste Test mit einem Aqara Türsensor lief einwandfrei 👍
                                        Das Pairing läuft schonmal definitiv schneller. Am Wochenende werden dann die restlichen
                                        Sensoren angelernt.

                                        1 Reply Last reply Reply Quote 0
                                        • MathiasJ
                                          MathiasJ @arteck last edited by

                                          @arteck
                                          Danke, nein, das Forum habe ich nicht gesehen, aber jetzt direkt in meinen Bookmarks aufgenommen.
                                          habe mal 2 von den Teilen bestellt.
                                          Bin gespannt, wie die Übertragungsrate und der Empfang ist.

                                          1 Reply Last reply Reply Quote 0
                                          • J
                                            Ja.rod last edited by

                                            Habe auch den CC2531, läuft nur meine Aqara Sensoren zicken etwas. Ich hatte den Converter schon mal installiert und dann den "Anlernknopf" beim jeweiligen Gerät vermisst (z.B. Osram Steckdose). Ich denke das kommt noch oder ist das überhaupt nicht mehr notwendig? Noch eine Frage eines Laien : Wie kann ich zwischen den Convertern hin und herwechseln, den anderen einfach wieder drüber installieren?

                                            Gruß
                                            Ja.rod

                                            v522533 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            960
                                            Online

                                            31.6k
                                            Users

                                            79.4k
                                            Topics

                                            1.3m
                                            Posts

                                            herdsman shpeherd zigbee adapter
                                            58
                                            498
                                            87016
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo