Navigation

    Logo
    • Register
    • Login
    • Search
    • Recent
    • Tags
    • Unread
    • Categories
    • Unreplied
    • Popular
    • GitHub
    • Docu
    • Hilfe
    1. Home
    2. Deutsch
    3. Tester
    4. Test Adapter Material Design Widgets v0.2.x

    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    Test Adapter Material Design Widgets v0.2.x

    This topic has been deleted. Only users with topic management privileges can see it.
    • Scrounger
      Scrounger Developer @sigi234 last edited by Scrounger

      @sigi234
      Mit der version davor hat es bei dir funktioniert?

      Poste mal den Wert der verwendeten Objekt Id.

      Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

      sigi234 1 Reply Last reply Reply Quote 0
      • Scrounger
        Scrounger Developer @smartboart last edited by Scrounger

        @smartboart
        Ok, das nutze ich nicht, teste nur mit MySql & Sqlite.

        Steht was im iobroker log zum history adapter, wenn du per vis die Daten lädst bzw. das Zeitinterval änderst.
        Funktionieren die Anzeige im Flot Adapter?

        @sigi234 @dos1973
        Welchen Adapter bzw. Datenbank verwendet ihr?

        Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

        sigi234 D smartboart 4 Replies Last reply Reply Quote 0
        • sigi234
          sigi234 Forum Testing Most Active @Scrounger last edited by Scrounger

          @Scrounger sagte in Material Design Widgets: Calendar Widget:

          @sigi234
          Mit der version davor hat es bei dir funktioniert?

          JA, alte Version geht noch immer.

          Poste mal den Wert der verwendeten Objekt Id.

          Screenshot (1649)_LI.jpg

          Fehler kommt auch schon wenn ich keine ID setze, also sobald ich das Widget in die Vis ziehe.

          Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

          Scrounger 1 Reply Last reply Reply Quote 0
          • sigi234
            sigi234 Forum Testing Most Active @Scrounger last edited by Scrounger

            @Scrounger sagte in Material Design Widgets: Line History Chart Widget:

            @smartboart
            Ok, das nutze ich nicht, teste nur mit MySql & Sqlite.

            Steht was im iobroker log zum history adapter, wenn du per vis die Daten lädst bzw. das Zeitinterval änderst.
            Funktionieren die Anzeige im Flot Adapter?

            @sigi234 @dos1973
            Welchen Adapter bzw. Datenbank verwendet ihr?

            History, Flot

            Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

            1 Reply Last reply Reply Quote 0
            • D
              dos1973 @Scrounger last edited by Scrounger

              @Scrounger
              ich logge auf (Syno) MariaDB/mysql

              Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

              1 Reply Last reply Reply Quote 0
              • smartboart
                smartboart @Scrounger last edited by Scrounger

                @Scrounger sagte in Material Design Widgets: Line History Chart Widget:

                Funktionieren die Anzeige im Flot Adapter?

                ja mit dem flot Adapter hat alles funktioniert....Wechselte hauptsächlich wegen der Möglichkeit Daten innerhalb des Charts auszublenden, was mit dem Flot zwar funktioniert aber nicht im fullybrowser und wegen der Intervalländerungsmöglickeit in Vis was beim Flot per Zoom auch nur am PC funktionierte und nicht im fully browser....

                Was benötige ich den alles um das mit SQL zu machen? Reicht da der Adapter aus oder brauche ich da nen extraserver? Wie ist der Resourcenverbrauch vom SQL Adapter?

                Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

                1 Reply Last reply Reply Quote 0
                • smartboart
                  smartboart @Scrounger last edited by Scrounger

                  @Scrounger sagte in Material Design Widgets: Line History Chart Widget:

                  Steht was im iobroker log zum history adapter, wenn du per vis die Daten lädst bzw. das Zeitinterval änderst.

                  Nein im log steht nichts Auffälliges , steht auf Debug siehe spoiler...


                  2020-02-12 08:25:29.327 - info: host.ioBroker-Rock instance system.adapter.history.0 started with pid 7158
                  2020-02-12 08:25:30.948 - debug: history.0 (7158) Redis Objects: Use Redis connection: 127.0.0.1:6379
                  2020-02-12 08:25:31.039 - debug: history.0 (7158) Objects client ready ... initialize now
                  2020-02-12 08:25:31.049 - debug: history.0 (7158) Objects create System PubSub Client
                  2020-02-12 08:25:31.051 - debug: history.0 (7158) Objects create User PubSub Client
                  2020-02-12 08:25:31.053 - debug: history.0 (7158) Objects client initialize lua scripts
                  2020-02-12 08:25:31.077 - debug: history.0 (7158) Objects connected to redis: 127.0.0.1:6379
                  2020-02-12 08:25:31.090 - debug: history.0 (7158) objectDB connected
                  2020-02-12 08:25:31.096 - debug: history.0 (7158) Redis States: Use Redis connection: 127.0.0.1:6379
                  2020-02-12 08:25:31.106 - debug: history.0 (7158) States create User PubSub Client
                  2020-02-12 08:25:31.111 - debug: history.0 (7158) States create System PubSub Client
                  2020-02-12 08:25:31.124 - debug: history.0 (7158) States connected to redis: 127.0.0.1:6379
                  2020-02-12 08:25:31.126 - debug: history.0 (7158) statesDB connected
                  2020-02-12 08:25:31.352 - info: history.0 (7158) starting. Version 1.8.7 in /opt/iobroker/node_modules/iobroker.history, node: v10.19.0
                  2020-02-12 08:25:32.521 - info: history.0 (7158) enabled logging of hm-rpc.0.PEQ0390467.1.MOTION (Count=1), Alias=false
                  2020-02-12 08:25:32.524 - info: history.0 (7158) enabled logging of javascript.0.InnenbereichMotion.Gesamt.STATE (Count=2), Alias=false
                  2020-02-12 08:25:32.525 - info: history.0 (7158) enabled logging of javascript.0.Messwerte.Garage.12V_Batterie (Count=3), Alias=false
                  2020-02-12 08:25:32.528 - info: history.0 (7158) enabled logging of modbus.0.holdingRegisters.12288_Arbeit (Count=4), Alias=false
                  2020-02-12 08:25:32.529 - info: history.0 (7158) enabled logging of modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt (Count=5), Alias=false
                  2020-02-12 08:25:32.531 - info: history.0 (7158) enabled logging of modbus.0.holdingRegisters.8216_Wirkleistung_L1 (Count=6), Alias=false
                  2020-02-12 08:25:32.532 - info: history.0 (7158) enabled logging of modbus.0.holdingRegisters.8218_Wirkleistung_L2 (Count=7), Alias=false
                  2020-02-12 08:25:32.533 - info: history.0 (7158) enabled logging of modbus.0.holdingRegisters.8220_Wirkleistung_L3 (Count=8), Alias=false
                  2020-02-12 08:25:32.535 - info: history.0 (7158) enabled logging of modbus.1.inputRegisters.30004Panel_Spannung (Count=9), Alias=false
                  2020-02-12 08:25:32.536 - info: history.0 (7158) enabled logging of modbus.1.inputRegisters.30005Panel_Strom (Count=10), Alias=false
                  2020-02-12 08:25:32.538 - info: history.0 (7158) enabled logging of modbus.1.inputRegisters.30007Panel_Leistung (Count=11), Alias=false
                  2020-02-12 08:25:32.539 - info: history.0 (7158) enabled logging of modbus.1.inputRegisters.30013Panel_Leistung (Count=12), Alias=false
                  2020-02-12 08:25:32.541 - info: history.0 (7158) enabled logging of modbus.1.inputRegisters.30016Ausgangs_Strom (Count=13), Alias=false
                  2020-02-12 08:25:32.542 - info: history.0 (7158) enabled logging of modbus.1.inputRegisters.30028Erzeugte_Leistung heute (Count=14), Alias=false
                  2020-02-12 08:25:32.544 - info: history.0 (7158) enabled logging of modbus.1.inputRegisters.30030Erzeugte_Leistung gesamt (Count=15), Alias=false
                  2020-02-12 08:25:32.545 - info: history.0 (7158) enabled logging of sonoff.0.Wemo_Dachboden.POWER6 (Count=16), Alias=false
                  2020-02-12 08:25:32.547 - info: history.0 (7158) enabled logging of sonoff.0.Wemo_Eingang.POWER5 (Count=17), Alias=false
                  2020-02-12 08:25:32.548 - info: history.0 (7158) enabled logging of sonoff.0.Wemo_Garage.BME280_Temperature (Count=18), Alias=false
                  2020-02-12 08:25:32.550 - info: history.0 (7158) enabled logging of sonoff.0.Wemo_Garage.POWER5 (Count=19), Alias=false
                  2020-02-12 08:25:32.551 - info: history.0 (7158) enabled logging of sonoff.0.Wemo_Huette.POWER5 (Count=20), Alias=false
                  2020-02-12 08:25:32.553 - info: history.0 (7158) enabled logging of sonoff.0.Wemo_Schuppen.POWER5 (Count=21), Alias=false
                  2020-02-12 08:25:32.554 - info: history.0 (7158) enabled logging of statistics.0.save.sumDelta.modbus.0.holdingRegisters.12288_Arbeit.day (Count=22), Alias=false
                  2020-02-12 08:25:32.556 - info: history.0 (7158) enabled logging of statistics.0.save.sumDelta.modbus.0.holdingRegisters.12288_Arbeit.month (Count=23), Alias=false
                  2020-02-12 08:25:32.557 - info: history.0 (7158) enabled logging of statistics.0.save.sumDelta.modbus.0.holdingRegisters.12288_Arbeit.week (Count=24), Alias=false
                  2020-02-12 08:25:32.559 - info: history.0 (7158) enabled logging of statistics.0.save.sumDelta.modbus.1.inputRegisters.30030Erzeugte_Leistung gesamt.day (Count=25), Alias=false
                  2020-02-12 08:25:32.560 - info: history.0 (7158) enabled logging of statistics.0.save.sumDelta.modbus.1.inputRegisters.30030Erzeugte_Leistung gesamt.hour (Count=26), Alias=false
                  2020-02-12 08:25:32.562 - info: history.0 (7158) enabled logging of statistics.0.save.sumDelta.modbus.1.inputRegisters.30030Erzeugte_Leistung gesamt.month (Count=27), Alias=false
                  2020-02-12 08:25:32.563 - info: history.0 (7158) enabled logging of statistics.0.save.sumDelta.modbus.1.inputRegisters.30030Erzeugte_Leistung gesamt.week (Count=28), Alias=false
                  2020-02-12 08:25:32.565 - info: history.0 (7158) enabled logging of statistics.0.save.sumDelta.modbus.1.inputRegisters.30030Erzeugte_Leistung gesamt.year (Count=29), Alias=false
                  2020-02-12 08:25:32.566 - info: history.0 (7158) enabled logging of wiffi-wz.0.root.192_168_1_52.w_lux (Count=30), Alias=false
                  2020-02-12 08:25:32.568 - info: history.0 (7158) enabled logging of wiffi-wz.0.root.192_168_1_54.wz_motion_left (Count=31), Alias=false
                  2020-02-12 08:25:32.569 - info: history.0 (7158) enabled logging of wiffi-wz.0.root.192_168_1_54.wz_motion_right (Count=32), Alias=false
                  2020-02-12 08:25:32.570 - info: history.0 (7158) enabled logging of wiffi-wz.0.root.192_168_1_54.wz_noise (Count=33), Alias=false
                  2020-02-12 08:25:32.614 - debug: history.0 (7158) Min-Delta ignored because no number hm-rpc.0.PEQ0390467.1.MOTION, last-value=null, new-value=false, ts=1581492332578
                  2020-02-12 08:25:32.616 - debug: history.0 (7158) Min-Delta ignored because no number javascript.0.InnenbereichMotion.Gesamt.STATE, last-value=null, new-value=false, ts=1581492332578
                  2020-02-12 08:25:32.618 - debug: history.0 (7158) Min-Delta reached javascript.0.Messwerte.Garage.12V_Batterie, last-value=null, new-value=11.804129999999999, ts=1581492332578
                  2020-02-12 08:25:32.620 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.12288_Arbeit, last-value=null, new-value=5129.88, ts=1581492332578
                  2020-02-12 08:25:32.622 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt, last-value=null, new-value=0.49, ts=1581492332578
                  2020-02-12 08:25:32.624 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8216_Wirkleistung_L1, last-value=null, new-value=0.14, ts=1581492332578
                  2020-02-12 08:25:32.625 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8218_Wirkleistung_L2, last-value=null, new-value=0.01, ts=1581492332578
                  2020-02-12 08:25:32.628 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8220_Wirkleistung_L3, last-value=null, new-value=0.34, ts=1581492332578
                  2020-02-12 08:25:32.629 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30004Panel_Spannung, last-value=null, new-value=164, ts=1581492332578
                  2020-02-12 08:25:32.630 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30005Panel_Strom, last-value=null, new-value=0, ts=1581492332578
                  2020-02-12 08:25:32.632 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30007Panel_Leistung, last-value=null, new-value=0, ts=1581492332578
                  2020-02-12 08:25:32.633 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30013Panel_Leistung, last-value=null, new-value=0, ts=1581492332578
                  2020-02-12 08:25:32.634 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30016Ausgangs_Strom, last-value=null, new-value=0, ts=1581492332578
                  2020-02-12 08:25:32.636 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30028Erzeugte_Leistung heute, last-value=null, new-value=0, ts=1581492332578
                  2020-02-12 08:25:32.637 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30030Erzeugte_Leistung gesamt, last-value=null, new-value=43, ts=1581492332578
                  2020-02-12 08:25:32.639 - debug: history.0 (7158) Min-Delta ignored because no number sonoff.0.Wemo_Eingang.POWER5, last-value=null, new-value=false, ts=1581492332578
                  2020-02-12 08:25:32.640 - debug: history.0 (7158) Min-Delta reached sonoff.0.Wemo_Garage.BME280_Temperature, last-value=null, new-value=4, ts=1581492332578
                  2020-02-12 08:25:32.641 - debug: history.0 (7158) Min-Delta ignored because no number sonoff.0.Wemo_Garage.POWER5, last-value=null, new-value=false, ts=1581492332578
                  2020-02-12 08:25:32.643 - debug: history.0 (7158) Min-Delta ignored because no number sonoff.0.Wemo_Huette.POWER5, last-value=null, new-value=false, ts=1581492332578
                  2020-02-12 08:25:32.644 - debug: history.0 (7158) Min-Delta ignored because no number sonoff.0.Wemo_Schuppen.POWER5, last-value=null, new-value=false, ts=1581492332578
                  2020-02-12 08:25:32.645 - debug: history.0 (7158) Min-Delta reached statistics.0.save.sumDelta.modbus.0.holdingRegisters.12288_Arbeit.day, last-value=null, new-value=10.539999999999964, ts=1581492332578
                  2020-02-12 08:25:32.647 - debug: history.0 (7158) Min-Delta reached statistics.0.save.sumDelta.modbus.0.holdingRegisters.12288_Arbeit.month, last-value=null, new-value=258.4499999999998, ts=1581492332578
                  2020-02-12 08:25:32.648 - debug: history.0 (7158) Min-Delta reached statistics.0.save.sumDelta.modbus.0.holdingRegisters.12288_Arbeit.week, last-value=null, new-value=53.659999999998945, ts=1581492332578
                  2020-02-12 08:25:32.649 - debug: history.0 (7158) Min-Delta reached statistics.0.save.sumDelta.modbus.1.inputRegisters.30030Erzeugte_Leistung gesamt.day, last-value=null, new-value=0.8999999999999986, ts=1581492332578
                  2020-02-12 08:25:32.650 - debug: history.0 (7158) Min-Delta reached statistics.0.save.sumDelta.modbus.1.inputRegisters.30030Erzeugte_Leistung gesamt.hour, last-value=null, new-value=0, ts=1581492332578
                  2020-02-12 08:25:32.651 - debug: history.0 (7158) Min-Delta reached statistics.0.save.sumDelta.modbus.1.inputRegisters.30030Erzeugte_Leistung gesamt.month, last-value=null, new-value=11.500000000000004, ts=1581492332578
                  2020-02-12 08:25:32.652 - debug: history.0 (7158) Min-Delta reached statistics.0.save.sumDelta.modbus.1.inputRegisters.30030Erzeugte_Leistung gesamt.week, last-value=null, new-value=5, ts=1581492332578
                  2020-02-12 08:25:32.653 - debug: history.0 (7158) Min-Delta reached statistics.0.save.sumDelta.modbus.1.inputRegisters.30030Erzeugte_Leistung gesamt.year, last-value=null, new-value=9.399999999999999, ts=1581492332578
                  2020-02-12 08:25:32.655 - debug: history.0 (7158) Min-Delta reached wiffi-wz.0.root.192_168_1_52.w_lux, last-value=null, new-value=808.5, ts=1581492332578
                  2020-02-12 08:25:32.656 - debug: history.0 (7158) Min-Delta ignored because no number wiffi-wz.0.root.192_168_1_54.wz_motion_left, last-value=null, new-value=true, ts=1581492332578
                  2020-02-12 08:25:32.657 - debug: history.0 (7158) Min-Delta ignored because no number wiffi-wz.0.root.192_168_1_54.wz_motion_right, last-value=null, new-value=false, ts=1581492332578
                  2020-02-12 08:25:32.658 - debug: history.0 (7158) Min-Delta ignored because no number wiffi-wz.0.root.192_168_1_54.wz_noise, last-value=null, new-value=false, ts=1581492332578
                  2020-02-12 08:25:34.689 - debug: history.0 (7158) system.adapter.admin.0: logging true
                  2020-02-12 08:25:40.355 - debug: history.0 (7158) Min-Delta ignored because no number wiffi-wz.0.root.192_168_1_54.wz_motion_left, last-value=true, new-value=false, ts=1581492339957
                  2020-02-12 08:25:40.357 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_right, last-value=false, new-value=false, ts=1581492339957
                  2020-02-12 08:25:40.359 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_noise, last-value=false, new-value=false, ts=1581492339958
                  2020-02-12 08:25:42.267 - debug: history.0 (7158) Min-Delta reached wiffi-wz.0.root.192_168_1_52.w_lux, last-value=808.5, new-value=802.5, ts=1581492341889
                  2020-02-12 08:25:43.758 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:25:43.775 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:25:43.792 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:25:43.815 - debug: history.0 (7158) Min-Delta reached wiffi-wz.0.root.192_168_1_52.w_lux, last-value=802.5, new-value=777, ts=1581492343374
                  2020-02-12 08:25:43.864 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:25:43.900 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:25:43.929 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:25:43.958 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:25:44.013 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:25:44.162 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:25:44.221 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:25:44.265 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:25:44.322 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:25:44.687 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:25:44.757 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:25:44.885 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:25:45.125 - debug: history.0 (7158) Send: 107 of: 588 in: 1349ms
                  2020-02-12 08:25:45.128 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:25:45.243 - debug: history.0 (7158) Send: 179 of: 1557 in: 1450ms
                  2020-02-12 08:25:45.245 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:25:45.348 - debug: history.0 (7158) Send: 188 of: 2853 in: 1591ms
                  2020-02-12 08:25:45.350 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:25:45.415 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:25:45.456 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:25:45.486 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:25:45.556 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:25:45.583 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:25:45.683 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:25:45.769 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:25:45.806 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:25:45.956 - debug: history.0 (7158) Send: 188 of: 2853 in: 2056ms
                  2020-02-12 08:25:45.957 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:25:45.986 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:25:45.989 - debug: history.0 (7158) Send: 107 of: 588 in: 2060ms
                  2020-02-12 08:25:45.990 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:25:46.017 - debug: history.0 (7158) Send: 179 of: 1557 in: 2059ms
                  2020-02-12 08:25:46.019 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:25:46.048 - debug: history.0 (7158) Send: 107 of: 588 in: 1827ms
                  2020-02-12 08:25:46.049 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:25:46.055 - debug: history.0 (7158) Send: 189 of: 2853 in: 1892ms
                  2020-02-12 08:25:46.056 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:25:46.075 - debug: history.0 (7158) Send: 231 of: 3967 in: 2211ms
                  2020-02-12 08:25:46.076 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:25:46.082 - debug: history.0 (7158) Send: 180 of: 1557 in: 1817ms
                  2020-02-12 08:25:46.084 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:25:46.100 - debug: history.0 (7158) Send: 231 of: 3967 in: 2087ms
                  2020-02-12 08:25:46.102 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:25:46.151 - debug: history.0 (7158) Send: 232 of: 3967 in: 1829ms
                  2020-02-12 08:25:46.153 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:25:49.581 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt, last-value=0.49, new-value=0.48, ts=1581492349545
                  2020-02-12 08:25:49.582 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8216_Wirkleistung_L1, last-value=0.14, new-value=0.13, ts=1581492349545
                  2020-02-12 08:25:53.438 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30004Panel_Spannung, last-value=164, new-value=165.2, ts=1581492353429
                  2020-02-12 08:26:01.410 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt, last-value=0.48, new-value=0.49, ts=1581492361379
                  2020-02-12 08:26:01.412 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8216_Wirkleistung_L1, last-value=0.13, new-value=0.15, ts=1581492361380
                  2020-02-12 08:26:03.726 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30004Panel_Spannung, last-value=165.2, new-value=165.8, ts=1581492363709
                  2020-02-12 08:26:03.758 - debug: history.0 (7158) Min-Delta reached wiffi-wz.0.root.192_168_1_52.w_lux, last-value=777, new-value=743.5, ts=1581492363376
                  2020-02-12 08:26:04.742 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_52.w_lux, last-value=743.5, new-value=743.5, ts=1581492364366
                  2020-02-12 08:26:10.386 - debug: history.0 (7158) Min-Delta ignored because no number wiffi-wz.0.root.192_168_1_54.wz_motion_left, last-value=false, new-value=true, ts=1581492369979
                  2020-02-12 08:26:10.387 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_right, last-value=false, new-value=false, ts=1581492369980
                  2020-02-12 08:26:10.388 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_noise, last-value=false, new-value=false, ts=1581492369980
                  2020-02-12 08:26:13.337 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_52.w_lux, last-value=743.5, new-value=743.5, ts=1581492372945
                  2020-02-12 08:26:13.398 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt, last-value=0.49, new-value=0.5, ts=1581492373381
                  2020-02-12 08:26:13.891 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30004Panel_Spannung, last-value=165.8, new-value=166.4, ts=1581492373886
                  2020-02-12 08:26:16.704 - debug: history.0 (7158) Min-Delta ignored because no number sonoff.0.Wemo_Eingang.POWER5, last-value=false, new-value=true, ts=1581492376701
                  2020-02-12 08:26:20.502 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:20.517 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:20.532 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:20.544 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:20.557 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:20.582 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:20.603 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:20.633 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:20.727 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:20.777 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:20.806 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:20.826 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:21.945 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:26:21.991 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:26:22.046 - debug: history.0 (7158) got 4 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:26:22.168 - debug: history.0 (7158) got 4 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:26:22.243 - debug: history.0 (7158) got 5 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:26:22.272 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:26:22.323 - debug: history.0 (7158) got 4 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:26:22.360 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:26:22.379 - debug: history.0 (7158) Send: 106 of: 588 in: 1862ms
                  2020-02-12 08:26:22.380 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:22.429 - debug: history.0 (7158) got 5 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:26:22.509 - debug: history.0 (7158) got 5 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:26:22.580 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:26:22.622 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:26:22.635 - debug: history.0 (7158) Send: 179 of: 1557 in: 2104ms
                  2020-02-12 08:26:22.663 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:22.666 - debug: history.0 (7158) Send: 109 of: 588 in: 1889ms
                  2020-02-12 08:26:22.680 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:22.683 - debug: history.0 (7158) Send: 106 of: 588 in: 2101ms
                  2020-02-12 08:26:22.696 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:22.717 - debug: history.0 (7158) Send: 189 of: 2855 in: 2215ms
                  2020-02-12 08:26:22.718 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:22.840 - debug: history.0 (7158) Send: 189 of: 2855 in: 2283ms
                  2020-02-12 08:26:22.842 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:22.848 - debug: history.0 (7158) Send: 189 of: 2855 in: 2121ms
                  2020-02-12 08:26:22.849 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:22.869 - debug: history.0 (7158) Send: 179 of: 1557 in: 2063ms
                  2020-02-12 08:26:22.870 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:22.926 - debug: history.0 (7158) Send: 233 of: 3970 in: 2382ms
                  2020-02-12 08:26:22.928 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:22.937 - debug: history.0 (7158) Send: 179 of: 1557 in: 2334ms
                  2020-02-12 08:26:22.938 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:22.982 - debug: history.0 (7158) Send: 232 of: 3970 in: 2156ms
                  2020-02-12 08:26:22.983 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:23.001 - debug: history.0 (7158) Send: 233 of: 3970 in: 2368ms
                  2020-02-12 08:26:23.002 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:23.179 - debug: history.0 (7158) Min-Delta ignored because no number wiffi-wz.0.root.192_168_1_54.wz_motion_left, last-value=true, new-value=false, ts=1581492382044
                  2020-02-12 08:26:23.181 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_right, last-value=false, new-value=false, ts=1581492382045
                  2020-02-12 08:26:23.182 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_noise, last-value=false, new-value=false, ts=1581492382045
                  2020-02-12 08:26:24.135 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30004Panel_Spannung, last-value=166.4, new-value=165.8, ts=1581492384120
                  2020-02-12 08:26:24.910 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:24.922 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:24.934 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:24.945 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:24.961 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:24.986 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:25.010 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:25.074 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:25.116 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:25.148 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:25.182 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:25.229 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:25.391 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt, last-value=0.5, new-value=0.49, ts=1581492385380
                  2020-02-12 08:26:25.401 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8216_Wirkleistung_L1, last-value=0.15, new-value=0.14, ts=1581492385380
                  2020-02-12 08:26:25.776 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.12288_Arbeit, last-value=5129.88, new-value=5129.89, ts=1581492385764
                  2020-02-12 08:26:26.128 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:26:26.417 - debug: history.0 (7158) got 4 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:26:26.458 - debug: history.0 (7158) got 6 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:26:26.501 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:26:26.563 - debug: history.0 (7158) got 5 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:26:26.583 - debug: history.0 (7158) Send: 180 of: 1557 in: 1649ms
                  2020-02-12 08:26:26.585 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:26.625 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:26:26.724 - debug: history.0 (7158) Send: 107 of: 588 in: 1802ms
                  2020-02-12 08:26:26.726 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:26.765 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:26:26.802 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:26:26.841 - debug: history.0 (7158) got 5 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:26:26.886 - debug: history.0 (7158) got 6 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:26:26.937 - debug: history.0 (7158) got 6 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:26:27.017 - debug: history.0 (7158) Send: 180 of: 1557 in: 2007ms
                  2020-02-12 08:26:27.018 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:27.038 - debug: history.0 (7158) Send: 107 of: 588 in: 1890ms
                  2020-02-12 08:26:27.040 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:27.056 - debug: history.0 (7158) Send: 107 of: 588 in: 2070ms
                  2020-02-12 08:26:27.057 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:27.082 - debug: history.0 (7158) Send: 188 of: 2856 in: 2172ms
                  2020-02-12 08:26:27.083 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:27.115 - debug: history.0 (7158) Send: 188 of: 2855 in: 2154ms
                  2020-02-12 08:26:27.120 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:27.141 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:26:27.190 - debug: history.0 (7158) Send: 232 of: 3971 in: 2245ms
                  2020-02-12 08:26:27.191 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:27.276 - debug: history.0 (7158) Send: 190 of: 2856 in: 2160ms
                  2020-02-12 08:26:27.277 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:27.324 - debug: history.0 (7158) Send: 232 of: 3971 in: 2250ms
                  2020-02-12 08:26:27.326 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:27.338 - debug: history.0 (7158) Send: 178 of: 1557 in: 2157ms
                  2020-02-12 08:26:27.352 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:27.383 - debug: history.0 (7158) Send: 233 of: 3971 in: 2154ms
                  2020-02-12 08:26:27.384 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:27.814 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:27.877 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:27.900 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:27.912 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:27.925 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:27.939 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:27.961 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:27.996 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:28.050 - debug: history.0 (7158) Min-Delta ignored because no number sonoff.0.Wemo_Eingang.POWER5, last-value=true, new-value=false, ts=1581492387952
                  2020-02-12 08:26:28.052 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:28.097 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:28.129 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:28.153 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:26:29.234 - debug: history.0 (7158) got 5 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:26:29.278 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:26:29.318 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:26:29.584 - debug: history.0 (7158) got 6 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:26:29.603 - debug: history.0 (7158) Send: 106 of: 588 in: 1726ms
                  2020-02-12 08:26:29.604 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:29.669 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:26:29.700 - debug: history.0 (7158) got 5 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:26:29.742 - debug: history.0 (7158) got 6 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:26:29.769 - debug: history.0 (7158) got 5 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:26:29.792 - debug: history.0 (7158) Send: 180 of: 1557 in: 1892ms
                  2020-02-12 08:26:29.793 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:29.841 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:26:29.868 - debug: history.0 (7158) got 6 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:26:29.918 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:26:29.922 - debug: history.0 (7158) Send: 106 of: 588 in: 1983ms
                  2020-02-12 08:26:29.923 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:29.974 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:26:29.989 - debug: history.0 (7158) Send: 188 of: 2856 in: 2175ms
                  2020-02-12 08:26:29.990 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:30.165 - debug: history.0 (7158) Send: 107 of: 588 in: 2068ms
                  2020-02-12 08:26:30.166 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:30.199 - debug: history.0 (7158) Send: 189 of: 2856 in: 2146ms
                  2020-02-12 08:26:30.201 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:30.223 - debug: history.0 (7158) Send: 180 of: 1557 in: 2262ms
                  2020-02-12 08:26:30.224 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:30.276 - debug: history.0 (7158) Send: 188 of: 2856 in: 2351ms
                  2020-02-12 08:26:30.277 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:30.285 - debug: history.0 (7158) Send: 179 of: 1557 in: 2156ms
                  2020-02-12 08:26:30.286 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:30.347 - debug: history.0 (7158) Send: 232 of: 3971 in: 2435ms
                  2020-02-12 08:26:30.348 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:30.381 - debug: history.0 (7158) Send: 232 of: 3971 in: 2385ms
                  2020-02-12 08:26:30.383 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:30.399 - debug: history.0 (7158) Send: 232 of: 3971 in: 2246ms
                  2020-02-12 08:26:30.400 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:26:30.453 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_left, last-value=false, new-value=false, ts=1581492389117
                  2020-02-12 08:26:30.455 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_right, last-value=false, new-value=false, ts=1581492389118
                  2020-02-12 08:26:30.456 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_noise, last-value=false, new-value=false, ts=1581492389135
                  2020-02-12 08:26:30.513 - debug: history.0 (7158) Min-Delta ignored because no number sonoff.0.Wemo_Eingang.POWER5, last-value=false, new-value=true, ts=1581492390503
                  2020-02-12 08:26:34.091 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_left, last-value=false, new-value=false, ts=1581492394079
                  2020-02-12 08:26:34.092 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_right, last-value=false, new-value=false, ts=1581492394080
                  2020-02-12 08:26:34.431 - debug: history.0 (7158) Min-Delta ignored because no number wiffi-wz.0.root.192_168_1_54.wz_noise, last-value=false, new-value=true, ts=1581492394080
                  2020-02-12 08:26:34.439 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30004Panel_Spannung, last-value=165.8, new-value=171.1, ts=1581492394428
                  2020-02-12 08:26:35.107 - debug: history.0 (7158) Min-Delta reached wiffi-wz.0.root.192_168_1_52.w_lux, last-value=743.5, new-value=693, ts=1581492394742
                  2020-02-12 08:26:36.703 - debug: history.0 (7158) Min-Delta ignored because no number sonoff.0.Wemo_Eingang.POWER5, last-value=true, new-value=false, ts=1581492396700
                  2020-02-12 08:26:40.224 - debug: history.0 (7158) Min-Delta ignored because no number sonoff.0.Wemo_Eingang.POWER5, last-value=false, new-value=true, ts=1581492400221
                  2020-02-12 08:26:44.538 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30004Panel_Spannung, last-value=171.1, new-value=165.8, ts=1581492404534
                  2020-02-12 08:26:46.404 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_left, last-value=false, new-value=false, ts=1581492406020
                  2020-02-12 08:26:46.405 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_right, last-value=false, new-value=false, ts=1581492406020
                  2020-02-12 08:26:46.406 - debug: history.0 (7158) Min-Delta ignored because no number wiffi-wz.0.root.192_168_1_54.wz_noise, last-value=true, new-value=false, ts=1581492406021
                  2020-02-12 08:26:49.429 - debug: history.0 (7158) Min-Delta ignored because no number wiffi-wz.0.root.192_168_1_54.wz_motion_left, last-value=false, new-value=true, ts=1581492409042
                  2020-02-12 08:26:49.431 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_right, last-value=false, new-value=false, ts=1581492409042
                  2020-02-12 08:26:49.432 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_noise, last-value=false, new-value=false, ts=1581492409042
                  2020-02-12 08:26:49.443 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt, last-value=0.49, new-value=0.44, ts=1581492409413
                  2020-02-12 08:26:49.446 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8216_Wirkleistung_L1, last-value=0.14, new-value=0.11, ts=1581492409413
                  2020-02-12 08:26:49.447 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8220_Wirkleistung_L3, last-value=0.34, new-value=0.32, ts=1581492409413
                  2020-02-12 08:26:50.953 - debug: history.0 (7158) Min-Delta ignored because no number sonoff.0.Wemo_Eingang.POWER5, last-value=true, new-value=false, ts=1581492410950
                  2020-02-12 08:26:54.699 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30004Panel_Spannung, last-value=165.8, new-value=181.8, ts=1581492414695
                  2020-02-12 08:26:55.756 - debug: history.0 (7158) Min-Delta reached wiffi-wz.0.root.192_168_1_52.w_lux, last-value=693, new-value=646.5, ts=1581492415408
                  2020-02-12 08:27:00.876 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt, last-value=0.44, new-value=0.42, ts=1581492420865
                  2020-02-12 08:27:00.877 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8216_Wirkleistung_L1, last-value=0.11, new-value=0.09, ts=1581492420865
                  2020-02-12 08:27:01.477 - debug: history.0 (7158) Min-Delta ignored because no number wiffi-wz.0.root.192_168_1_54.wz_motion_left, last-value=true, new-value=false, ts=1581492421048
                  2020-02-12 08:27:01.479 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_right, last-value=false, new-value=false, ts=1581492421048
                  2020-02-12 08:27:01.480 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_noise, last-value=false, new-value=false, ts=1581492421049
                  2020-02-12 08:27:04.829 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_52.w_lux, last-value=646.5, new-value=646.5, ts=1581492424355
                  2020-02-12 08:27:04.886 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30004Panel_Spannung, last-value=181.8, new-value=164.6, ts=1581492424883
                  2020-02-12 08:27:10.526 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:10.544 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:10.559 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:10.572 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:10.584 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:10.597 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:10.608 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:10.621 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:10.654 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:10.685 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:10.710 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:10.734 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:11.848 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:27:11.911 - debug: history.0 (7158) got 7 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:27:12.002 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:27:12.050 - debug: history.0 (7158) got 8 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:27:12.117 - debug: history.0 (7158) got 3 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:27:12.162 - debug: history.0 (7158) got 8 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:27:12.203 - debug: history.0 (7158) got 8 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:27:12.249 - debug: history.0 (7158) got 7 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:27:12.252 - debug: history.0 (7158) Send: 111 of: 588 in: 1708ms
                  2020-02-12 08:27:12.253 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:12.330 - debug: history.0 (7158) got 3 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:27:12.357 - debug: history.0 (7158) got 3 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:27:12.391 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:27:12.413 - debug: history.0 (7158) Send: 111 of: 588 in: 1817ms
                  2020-02-12 08:27:12.414 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:12.505 - debug: history.0 (7158) got 7 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:27:12.555 - debug: history.0 (7158) Send: 192 of: 2858 in: 1971ms
                  2020-02-12 08:27:12.556 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:12.576 - debug: history.0 (7158) Send: 181 of: 1558 in: 1968ms
                  2020-02-12 08:27:12.577 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:12.610 - debug: history.0 (7158) Send: 110 of: 588 in: 1925ms
                  2020-02-12 08:27:12.619 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:12.649 - debug: history.0 (7158) Send: 181 of: 1558 in: 1939ms
                  2020-02-12 08:27:12.651 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:12.687 - debug: history.0 (7158) Send: 229 of: 3973 in: 2114ms
                  2020-02-12 08:27:12.688 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:12.693 - debug: history.0 (7158) Send: 181 of: 1558 in: 2135ms
                  2020-02-12 08:27:12.694 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:12.709 - debug: history.0 (7158) Send: 229 of: 3973 in: 2089ms
                  2020-02-12 08:27:12.710 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:12.724 - debug: history.0 (7158) Send: 192 of: 2858 in: 2198ms
                  2020-02-12 08:27:12.725 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:12.796 - debug: history.0 (7158) Send: 190 of: 2858 in: 2141ms
                  2020-02-12 08:27:12.798 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:12.802 - debug: history.0 (7158) Send: 230 of: 3973 in: 2068ms
                  2020-02-12 08:27:12.803 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:15.224 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30004Panel_Spannung, last-value=164.6, new-value=180.6, ts=1581492435221
                  2020-02-12 08:27:15.243 - debug: history.0 (7158) Min-Delta reached wiffi-wz.0.root.192_168_1_52.w_lux, last-value=646.5, new-value=630, ts=1581492434883
                  2020-02-12 08:27:15.256 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:15.274 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:15.286 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:15.298 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:15.316 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:15.337 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:15.368 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:15.392 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:15.416 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:15.437 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:15.469 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:15.490 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:16.624 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:27:16.748 - debug: history.0 (7158) got 3 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:27:16.767 - debug: history.0 (7158) got 7 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:27:16.818 - debug: history.0 (7158) got 8 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:27:16.873 - debug: history.0 (7158) got 3 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:27:16.924 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:27:16.935 - debug: history.0 (7158) Send: 112 of: 588 in: 1661ms
                  2020-02-12 08:27:16.951 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:17.067 - debug: history.0 (7158) got 7 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:27:17.126 - debug: history.0 (7158) got 3 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:27:17.207 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:27:17.257 - debug: history.0 (7158) got 7 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:27:17.300 - debug: history.0 (7158) got 8 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:27:17.337 - debug: history.0 (7158) Send: 112 of: 588 in: 2000ms
                  2020-02-12 08:27:17.338 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:17.357 - debug: history.0 (7158) Send: 180 of: 1558 in: 1989ms
                  2020-02-12 08:27:17.358 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:17.394 - debug: history.0 (7158) got 8 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:27:17.437 - debug: history.0 (7158) Send: 180 of: 1558 in: 2151ms
                  2020-02-12 08:27:17.438 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:17.480 - debug: history.0 (7158) Send: 191 of: 2858 in: 2164ms
                  2020-02-12 08:27:17.481 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:17.492 - debug: history.0 (7158) Send: 110 of: 588 in: 2055ms
                  2020-02-12 08:27:17.493 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:17.506 - debug: history.0 (7158) Send: 191 of: 2858 in: 2249ms
                  2020-02-12 08:27:17.506 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:17.534 - debug: history.0 (7158) Send: 229 of: 3973 in: 2236ms
                  2020-02-12 08:27:17.535 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:17.551 - debug: history.0 (7158) Send: 180 of: 1558 in: 2082ms
                  2020-02-12 08:27:17.552 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:17.622 - debug: history.0 (7158) Send: 192 of: 2858 in: 2206ms
                  2020-02-12 08:27:17.623 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:17.729 - debug: history.0 (7158) Send: 229 of: 3973 in: 2337ms
                  2020-02-12 08:27:17.730 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:17.768 - debug: history.0 (7158) Send: 230 of: 3973 in: 2278ms
                  2020-02-12 08:27:17.769 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:18.028 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:18.045 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:18.064 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:18.077 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:18.091 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:18.137 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:18.152 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:18.176 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:18.211 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:18.231 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:18.302 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:18.342 - debug: history.0 (7158) use parallel requests
                  2020-02-12 08:27:19.231 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:27:19.412 - debug: history.0 (7158) got 7 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:27:19.503 - debug: history.0 (7158) Send: 112 of: 588 in: 1458ms
                  2020-02-12 08:27:19.504 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:19.518 - debug: history.0 (7158) got 8 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:27:19.661 - debug: history.0 (7158) got 3 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:27:19.694 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:27:19.751 - debug: history.0 (7158) got 8 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:27:19.807 - debug: history.0 (7158) got 7 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:27:19.819 - debug: history.0 (7158) got 7 datapoints for modbus.0.holdingRegisters.8216_Wirkleistung_L1
                  2020-02-12 08:27:19.873 - debug: history.0 (7158) got 3 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:27:19.955 - debug: history.0 (7158) got 2 datapoints for modbus.0.holdingRegisters.8218_Wirkleistung_L2
                  2020-02-12 08:27:19.982 - debug: history.0 (7158) got 8 datapoints for modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt
                  2020-02-12 08:27:20.104 - debug: history.0 (7158) got 3 datapoints for modbus.0.holdingRegisters.8220_Wirkleistung_L3
                  2020-02-12 08:27:20.106 - debug: history.0 (7158) Send: 112 of: 588 in: 1969ms
                  2020-02-12 08:27:20.107 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:20.131 - debug: history.0 (7158) Send: 190 of: 2858 in: 2103ms
                  2020-02-12 08:27:20.132 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:20.170 - debug: history.0 (7158) Send: 190 of: 2858 in: 2079ms
                  2020-02-12 08:27:20.171 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:20.190 - debug: history.0 (7158) Send: 181 of: 1558 in: 2038ms
                  2020-02-12 08:27:20.191 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:20.224 - debug: history.0 (7158) Send: 110 of: 588 in: 1993ms
                  2020-02-12 08:27:20.224 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:20.304 - debug: history.0 (7158) Send: 181 of: 1558 in: 2240ms
                  2020-02-12 08:27:20.305 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:20.365 - debug: history.0 (7158) Send: 192 of: 2858 in: 2154ms
                  2020-02-12 08:27:20.366 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:20.382 - debug: history.0 (7158) Send: 229 of: 3973 in: 2305ms
                  2020-02-12 08:27:20.383 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:20.402 - debug: history.0 (7158) Send: 179 of: 1558 in: 2100ms
                  2020-02-12 08:27:20.403 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:20.422 - debug: history.0 (7158) Send: 230 of: 3973 in: 2080ms
                  2020-02-12 08:27:20.423 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:20.439 - debug: history.0 (7158) Send: 229 of: 3973 in: 2264ms
                  2020-02-12 08:27:20.440 - debug: history.0 (7158) sendTo "getHistory" to system.adapter.web.0 from system.adapter.history.0
                  2020-02-12 08:27:21.430 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_left, last-value=false, new-value=false, ts=1581492441079
                  2020-02-12 08:27:21.431 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_right, last-value=false, new-value=false, ts=1581492441079
                  2020-02-12 08:27:21.432 - debug: history.0 (7158) Min-Delta ignored because no number wiffi-wz.0.root.192_168_1_54.wz_noise, last-value=false, new-value=true, ts=1581492441079
                  2020-02-12 08:27:25.293 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30004Panel_Spannung, last-value=180.6, new-value=161.6, ts=1581492445290
                  2020-02-12 08:27:27.654 - debug: history.0 (7158) Min-Delta reached wiffi-wz.0.root.192_168_1_52.w_lux, last-value=630, new-value=588.5, ts=1581492446968
                  2020-02-12 08:27:27.660 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_left, last-value=false, new-value=false, ts=1581492447311
                  2020-02-12 08:27:27.661 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_right, last-value=false, new-value=false, ts=1581492447311
                  2020-02-12 08:27:27.662 - debug: history.0 (7158) Min-Delta ignored because no number wiffi-wz.0.root.192_168_1_54.wz_noise, last-value=true, new-value=false, ts=1581492447311
                  2020-02-12 08:27:29.435 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_left, last-value=false, new-value=false, ts=1581492449074
                  2020-02-12 08:27:29.436 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_motion_right, last-value=false, new-value=false, ts=1581492449074
                  2020-02-12 08:27:29.437 - debug: history.0 (7158) value not changed wiffi-wz.0.root.192_168_1_54.wz_noise, last-value=false, new-value=false, ts=1581492449075
                  2020-02-12 08:27:35.451 - debug: history.0 (7158) Min-Delta reached modbus.1.inputRegisters.30004Panel_Spannung, last-value=161.6, new-value=104.8, ts=1581492455448
                  2020-02-12 08:27:36.385 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8214_Wirkleistung_Gesamt, last-value=0.42, new-value=0.41, ts=1581492456368
                  2020-02-12 08:27:36.386 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8216_Wirkleistung_L1, last-value=0.09, new-value=0.07, ts=1581492456368
                  2020-02-12 08:27:36.386 - debug: history.0 (7158) Min-Delta reached modbus.0.holdingRegisters.8220_Wirkleistung_L3, last-value=0.32, new-value=0.33, ts=1581492456369
                  2020-02-12 08:27:37.992 - debug: history.0 (7158) Min-Delta reached wiffi-wz.0.root.192_168_1_52.w_lux, last-value=588.5, new-value=558.5, ts=1581492457635

                  Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

                  1 Reply Last reply Reply Quote 0
                  • Scrounger
                    Scrounger Developer @sigi234 last edited by Scrounger

                    @sigi234 sagte in Material Design Widgets: Calendar Widget:

                    Fehler kommt auch schon wenn ich keine ID setze, also sobald ich das Widget in die Vis ziehe.

                    Achja javascript kann schon zickig sein 😉
                    Habs gefunden, bitte aktuellen master testen.

                    Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

                    sigi234 1 Reply Last reply Reply Quote 0
                    • sigi234
                      sigi234 Forum Testing Most Active @Scrounger last edited by Scrounger

                      @Scrounger sagte in Material Design Widgets: Calendar Widget:

                      @sigi234 sagte in Material Design Widgets: Calendar Widget:

                      Fehler kommt auch schon wenn ich keine ID setze, also sobald ich das Widget in die Vis ziehe.

                      Achja javascript kann schon zickig sein 😉
                      Habs gefunden, bitte aktuellen master testen.

                      Leider geht es noch nicht.( V 0.2.52)

                      Bei reinziehen:

                      Screenshot (1653).png

                      Nach einfügen der ID:
                      Screenshot (1654)_LI.jpg

                      Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

                      Scrounger 1 Reply Last reply Reply Quote 0
                      • Scrounger
                        Scrounger Developer @sigi234 last edited by Scrounger

                        @sigi234

                        @sigi234 sagte in Material Design Widgets: Calendar Widget:

                        Bei reinziehen:
                        Screenshot (1653).png

                        Das ist eine Fehlermeldung die von der vuetify api kommt, kann ignoriert werden.

                        Nach einfügen der ID:
                        Screenshot (1654)_LI.jpg

                        Kann ich nicht reproduzieren. Brauch zwingend den Wert deines verwendeten Objektes!

                        Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

                        sigi234 1 Reply Last reply Reply Quote 0
                        • Scrounger
                          Scrounger Developer @J.A.R.V.I.S. last edited by Scrounger

                          @J-A-R-V-I-S
                          Ah das ist die entscheidende Info die mir gefehlt hat, wusste nicht das es neben dem ical Adapter noch einen weiteren Calendar Adapter gibt.
                          Schau ich mir an, ob man den auch integrieren kann.

                          Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

                          J.A.R.V.I.S. 1 Reply Last reply Reply Quote 0
                          • J.A.R.V.I.S.
                            J.A.R.V.I.S. Developer @Scrounger last edited by Scrounger

                            @Scrounger wenn du Hilfe benötigst, sag bescheid. Ich könnte sonst auch noch weitere DPs im Adapter zur Verfügung stellen.

                            Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

                            Scrounger 1 Reply Last reply Reply Quote 0
                            • sigi234
                              sigi234 Forum Testing Most Active @Scrounger last edited by Scrounger

                              @Scrounger
                              @J-A-R-V-I-S

                              Ich habe einfach eure Kalender verwechselt.
                              Aber so findet ihr zueinander. 😀

                              Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

                              1 Reply Last reply Reply Quote 0
                              • Scrounger
                                Scrounger Developer @J.A.R.V.I.S. last edited by Scrounger

                                @J-A-R-V-I-S
                                Das wäre natürlich top, wenn du einen Datenpunkt zur Verfügung stellst, der out of the box mit dem widget funktioniert.

                                Datenpunkt muss ein String sein, der wie folgt aussieht:

                                [
                                	{
                                		"name": "Event",
                                		"color": "#e74c3c",
                                		"colorText": "#FFFFFF",
                                		"start": "2020-01-24",
                                		"end": "2020-01-26"
                                	},
                                	{
                                		"name": "Meeting",
                                		"color": "#717d7e",
                                		"colorText": "#FFFFFF",
                                		"start": "2020-03-23",
                                		"end": "2020-03-24"
                                	}
                                ]
                                

                                Wichtig bei ganztägien Ereignissen darf nur das Datum bei start und end propertie drin sein:

                                		"start": "2020-03-23",
                                		"end": "2020-03-24"
                                

                                Bei Terminen muss noch die Zeit mit dazu, in folgendem Format (24h):

                                		"start": "2020-01-24 16:00",
                                		"end": "2020-01-26 17:15"
                                

                                Lass uns am besten über telegramm weiter kommunizieren

                                Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

                                J.A.R.V.I.S. 1 Reply Last reply Reply Quote 0
                                • J.A.R.V.I.S.
                                  J.A.R.V.I.S. Developer @Scrounger last edited by

                                  @Scrounger ich glaube, meine Datenpunkte haben schon eine ahnliche Struktur.

                                  @Scrounger sagte in Test Adapter Material Design Widgets v0.2.x:

                                  Lass uns am besten über telegramm weiter kommunizieren

                                  Können wir sehr gerne machen.

                                  1 Reply Last reply Reply Quote 0
                                  • C
                                    cmorlok last edited by

                                    @Scrounger (Sorry, wenn das schon mal beantwortet wurde, aber ich habe nichts gefunden)

                                    Was ist beste Entwicklungsprozess für Widgets? Kann am irgendwo im laufenden Vis die Dateien editieren? Wie machst Du das? Oder geht alles über git und einem (zeitintensiven) Update des Adapters?

                                    Scrounger 1 Reply Last reply Reply Quote 0
                                    • ub.privat
                                      ub.privat @Scrounger last edited by Scrounger

                                      @Scrounger

                                      Hallo, leider ich schon wieder...
                                      Nachdem das System nun wieder stabil und korrekt läuft, habe ich mich dem neuen Script angenommen.
                                      Der DP wird richtig angelgt und ich habe diesen im Widget angezogen.
                                      Verhalten nach wie vor identisch.

                                      Im Editor werden die Daten OHNE Kalenderfarben angezeigt, in der RunTime ist nur ein leerer Kalender zu sehen.
                                      Kurzum identisches Verhalten, wie mit dem "alten" DP.
                                      D.h. es muss einen anderen Fehler geben????

                                      Grüße

                                      Edit: in testing thread verschoben, da es fehlerbehbung betrifft und nicht die Einstellung des Widgets

                                      Scrounger 1 Reply Last reply Reply Quote 0
                                      • M
                                        mctom @Scrounger last edited by

                                        Diese Material Design kann einem ja echt den Kopf zerbrechen. Man hat so viele Ideen. 🙂

                                        Wenn man die Widgets installiert hat, stehen in den Widgets ja auch die Icons von https://materialdesignicons.com/ zur Verfügung.

                                        Ich würde jetzt an verschiedenen Stellen nur eines dieser Icons anzeigen.

                                        Hat jemand eine Idee wie ich das hinbekomme?

                                        Okay 🙂 beim schreiben habe ich eine Lösung gefunden:

                                        Basic HTML widget mit folgendem Inhalt:

                                        <span class="mdi mdi-lightbulb-on-outline" style="font-size: 40px"></span>
                                        

                                        Ich fände es cool wenn es ein fertiges Widget geben würde wo man die Icons direkt auswählen könnte.

                                        1 Reply Last reply Reply Quote 0
                                        • Scrounger
                                          Scrounger Developer @cmorlok last edited by

                                          @cmorlok sagte in Test Adapter Material Design Widgets v0.2.x:

                                          @Scrounger (Sorry, wenn das schon mal beantwortet wurde, aber ich habe nichts gefunden)

                                          Was ist beste Entwicklungsprozess für Widgets? Kann am irgendwo im laufenden Vis die Dateien editieren? Wie machst Du das? Oder geht alles über git und einem (zeitintensiven) Update des Adapters?

                                          Infos dazu findest du hier:
                                          https://forum.iobroker.net/topic/671/widget-entwicklung/2
                                          https://github.com/ioBroker/ioBroker.docs/tree/master/docs/en/dev
                                          https://github.com/ioBroker/ioBroker.docs/blob/master/docs/en/dev/adaptervis.md

                                          @mctom sagte in Test Adapter Material Design Widgets v0.2.x:

                                          Ich fände es cool wenn es ein fertiges Widget geben würde wo man die Icons direkt auswählen könnte.

                                          Steht schon auf der Todo Liste:
                                          https://github.com/Scrounger/ioBroker.vis-materialdesign/issues/52

                                          Scrounger created this issue in Scrounger/ioBroker.vis-materialdesign

                                          closed Material Design Icon Widget #52

                                          C 1 Reply Last reply Reply Quote 0
                                          • C
                                            cmorlok @Scrounger last edited by

                                            @Scrounger said in Test Adapter Material Design Widgets v0.2.x:

                                            Infos dazu findest du hier:
                                            https://forum.iobroker.net/topic/671/widget-entwicklung/2
                                            https://github.com/ioBroker/ioBroker.docs/tree/master/docs/en/dev
                                            https://github.com/ioBroker/ioBroker.docs/tree/master/docs/en/dev/adaptervis.md

                                            Danke, die Doku habe ich auch schon gelesen. Was mich aber verwirrt ist dieser Absatz:

                                            replace index.html and edit.html replace files in /opt/iobroker/iobroker-data/files/vis/index.html and edit.html with files from /opt/iobroker/node_modules/iobroker.vis/www/index.html.original and edit.html.original. Change the file /opt/iobroker/iobroker-data/files/vis/cache.manifest. No matter what, just one symbol to trigger the browser to load files anew. The files must be smaller than 200k. If you have got wrong files, so they are definitly largen than 400k.

                                            Warum sollte ich das tun? Die .original-Dateien gibt es noch nicht einmal?! (In der deutschen Übersetzung ist das noch seltsamer formuliert).

                                            Weshalb ich aber eigentlich frage ist Folgendes. Vis läd bei mir /opt/iobroker/iobroker-data/files/vis/widgets/materialdesign/js/widgets.min.js, das ja den Inhalt von vis/widgets/materialdesign/js/* enthält. Muss ich diese Datei jeweils neu erzeugen? Wenn ja, wie? Oder kann ich vis irgendwie dazu bringen, die Javascript-Quellen zu laden statt der minified?

                                            Scrounger 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            645
                                            Online

                                            31.7k
                                            Users

                                            79.7k
                                            Topics

                                            1.3m
                                            Posts

                                            adapater material vis visualization widget
                                            77
                                            902
                                            166915
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo