    4. [gelöst] Stromzähler B+G SDM630:Modbus RS 485/USB + mqtt ?

    NEWS

    • Neuer Blog: Fotos und Eindrücke aus Solingen

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    [gelöst] Stromzähler B+G SDM630:Modbus RS 485/USB + mqtt ?

    This topic has been deleted. Only users with topic management privileges can see it.
    • P
      panki2 @wendy2702 last edited by wendy2702

      @wendy
      Test konsolentext kopieren:

      2702 2020-02-21 15:28:09.457  - debug: modbus.0 (5096) system.adapter.admin.0: logging false
      2020-02-21 15:29:31.039  - info: modbus.0 (5096) List of port: [{"comName":"/dev/ttyAMA0"},{"manufacturer":"FTDI","serialNumber":"A6025B5V","pnpId":"usb-FTDI_FT232R_USB_UART_A6025B5V-if00-port0","vendorId":"0403","productId":"6001","comName":"/dev/ttyUSB0"}]
      2020-02-21 15:29:31.041  - debug: modbus.0 (5096) sendTo "listUart" to system.adapter.admin.0 from system.adapter.modbus.0
      2020-02-21 15:29:37.007  - debug: modbus.0 (5096) system.adapter.admin.0: logging true
      2020-02-21 15:28:09.457  - debug: modbus.0 (5096) system.adapter.admin.0: logging false
      2020-02-21 15:29:31.039  - info: modbus.0 (5096) List of port: [{"comName":"/dev/ttyAMA0"},{"manufacturer":"FTDI","serialNumber":"A6025B5V","pnpId":"usb-FTDI_FT232R_USB_UART_A6025B5V-if00-port0","vendorId":"0403","productId":"6001","comName":"/dev/ttyUSB0"}]
      2020-02-21 15:29:31.041  - debug: modbus.0 (5096) sendTo "listUart" to system.adapter.admin.0 from system.adapter.modbus.0
      2020-02-21 15:29:37.007  - debug: modbus.0 (5096) system.adapter.admin.0: logging true
      

      Beim nächsten mal noch Code Tag verwenden 😉

      0f66b44c-72d5-4fa7-8f13-9974bbd0f5d1-image.png

      1 Reply Last reply Reply Quote 0
      • wendy2702
        wendy2702 last edited by

        Kannst du mal die Version 3.0.0 des Adapters installieren, Von der weiß ich das Sie funktioniert.

        Geht auch im Experten Modus hier:

        0c751db5-1656-4d3c-b499-2871ba7c5c4f-image.png

        1 Reply Last reply Reply Quote 0
        • P
          panki2 last edited by

          Hallo, back again.
          Ich habe nun Version 3.0.0 installiert

          Nun kommt eine "Reaktion, welche ich aber nicht interpretieren kann.
          putty Konsole:

          • debug: modbus.0 (5868) Poll device 1
            2020-02-21 20:47:36.030 - debug: modbus.0 (5868) Poll holdingRegs DevID(1) address 48 - 6 bytes
            2020-02-21 20:47:36.066 - error: modbus.0 (5868) Wrong CRC for frame: 0,1,3,12,0,0,0,0
            2020-02-21 20:47:36.082 - error: modbus.0 (5868) unknown function code: 0
            2020-02-21 20:47:41.038 - warn: modbus.0 (5868) Error: undefined
            2020-02-21 20:47:41.039 - error: modbus.0 (5868) Request timed out.
            2020-02-21 20:47:41.042 - warn: modbus.0 (5868) Poll error count: 1 code: {"err":"timeout"}
            2020-02-21 20:47:42.043 - info: modbus.0 (5868) Disconnected from slave
            2020-02-21 20:47:42.052 - debug: modbus.0 (5868) Clearing timeout of the current request.
            2020-02-21 20:47:42.055 - debug: modbus.0 (5868) Cleaning up request fifo.
            2020-02-21 20:48:42.046 - debug: modbus.0 (5868) connect to serial /dev/ttyUSB0 with 9600
            2020-02-21 20:48:42.054 - info: modbus.0 (5868) Connected to slave
            2020-02-21 20:48:42.056 - debug: modbus.0 (5868) Poll device 1
            2020-02-21 20:48:42.058 - debug: modbus.0 (5868) Poll holdingRegs DevID(1) address 48 - 6 bytes
            2020-02-21 20:48:47.062 - warn: modbus.0 (5868) Error: undefined
            2020-02-21 20:48:47.064 - error: modbus.0 (5868) Request timed out.
            2020-02-21 20:48:47.066 - warn: modbus.0 (5868) Poll error count: 2 code: {"err":"timeout"}
            2020-02-21 20:48:48.067 - info: modbus.0 (5868) Disconnected from slave
            2020-02-21 20:48:48.074 - debug: modbus.0 (5868) Clearing timeout of the current request.
            2020-02-21 20:48:48.084 - debug: modbus.0 (5868) Cleaning up request fifo.
            2020-02-21 20:49:48.072 - debug: modbus.0 (5868) connect to serial /dev/ttyUSB0 with 9600
          1 Reply Last reply Reply Quote 0
          • P
            panki2 last edited by

            . es kommen aber nicht immer die selben Reaktionen:

            • debug: modbus.0 (4883) Poll device 1
              2020-02-21 20:38:28.353 - debug: modbus.0 (4883) Poll holdingRegs DevID(1) address 48 - 2 bytes
              2020-02-21 20:38:28.395 - debug: modbus.0 (4883) Poll holdingRegs DevID(1) address 30001 - 2 bytes
              2020-02-21 20:38:28.424 - error: modbus.0 (4883) Wrong CRC for frame: 0,1,3,4,0,0,0,0
              2020-02-21 20:38:33.398 - warn: modbus.0 (4883) Error: undefined
              2020-02-21 20:38:33.399 - error: modbus.0 (4883) Request timed out.
              2020-02-21 20:38:33.401 - warn: modbus.0 (4883) Poll error count: 1 code: {"err":"timeout"}
              2020-02-21 20:38:34.402 - info: modbus.0 (4883) Disconnected from slave
              2020-02-21 20:38:34.413 - debug: modbus.0 (4883) Clearing timeout of the current request.
              2020-02-21 20:38:34.415 - debug: modbus.0 (4883) Cleaning up request fifo.
              2020-02-21 20:39:34.407 - debug: modbus.0 (4883) connect to serial /dev/ttyUSB0 with 9600
              2020-02-21 20:39:34.415 - info: modbus.0 (4883) Connected to slave
            1 Reply Last reply Reply Quote 0
            • wendy2702
              wendy2702 last edited by

              @panki2 sagte in Stromzähler B+G E-Tech SDM630Modbus V2 via RS 485 /USB ?:

              address 48

              Lösche mal das Register mit Adresse 48 und zeige dann mal das log.

              P 1 Reply Last reply Reply Quote 0
              • P
                panki2 @wendy2702 last edited by

                @wendy2702 jetzt sind alle holding Register im iobroker "leer", also keine Einträge.
                Hast Du das so gemeint?
                2020-02-21 21:14:23.169 - info: host.raspberrypi instance system.adapter.modbus.0 started with pid 8483
                2020-02-21 21:14:24.769 - debug: modbus.0 (8483) Redis Objects: Use Redis connection: 127.0.0.1:9001
                2020-02-21 21:14:24.834 - debug: modbus.0 (8483) Objects client ready ... initialize now
                2020-02-21 21:14:24.843 - debug: modbus.0 (8483) Objects create System PubSub Client
                2020-02-21 21:14:24.845 - debug: modbus.0 (8483) Objects create User PubSub Client
                2020-02-21 21:14:24.847 - debug: modbus.0 (8483) Objects client initialize lua scripts
                2020-02-21 21:14:24.867 - debug: modbus.0 (8483) Objects connected to redis: 127.0.0.1:9001
                2020-02-21 21:14:24.892 - debug: modbus.0 (8483) objectDB connected
                2020-02-21 21:14:24.897 - debug: modbus.0 (8483) Redis States: Use Redis connection: 127.0.0.1:9000
                2020-02-21 21:14:24.909 - debug: modbus.0 (8483) States create User PubSub Client
                2020-02-21 21:14:24.914 - debug: modbus.0 (8483) States create System PubSub Client
                2020-02-21 21:14:24.926 - debug: modbus.0 (8483) States connected to redis: 127.0.0.1:9000
                2020-02-21 21:14:24.928 - debug: modbus.0 (8483) statesDB connected
                2020-02-21 21:14:25.302 - info: sql.0 (1474) enabled logging of modbus.0.info.connection, Alias=false
                2020-02-21 21:14:25.343 - info: modbus.0 (8483) starting. Version 3.0.0 in /opt/iobroker/node_modules/iobroker.modbus, node: v10.18.1
                2020-02-21 21:14:25.585 - info: sql.0 (1474) disabled logging of modbus.0.info.pollTime
                2020-02-21 21:14:26.044 - debug: modbus.0 (8483) connect to serial /dev/ttyUSB0 with 9600
                2020-02-21 21:14:26.065 - info: modbus.0 (8483) Connected to slave
                2020-02-21 21:14:26.070 - info: modbus.0 (8483) Disconnected from slave
                2020-02-21 21:14:26.077 - debug: modbus.0 (8483) Cleaning up request fifo.

                1 Reply Last reply Reply Quote 0
                • wendy2702
                  wendy2702 last edited by

                  Nö,

                  Du sollst einen Eintrag drin lassen.

                  Laut einem deiner Post gibt es ja die Adresse 30001, oder?

                  Teste mit der.

                  P 1 Reply Last reply Reply Quote 0
                  • P
                    panki2 @wendy2702 last edited by

                    @wendy2702 Sorry
                    jetzt stehht wieder die Adresse 30001 drin

                    Ergebnis
                    2020-02-21 21:29:38.277 - debug: modbus.0 (9908) States create System PubSub Client
                    2020-02-21 21:29:38.290 - debug: modbus.0 (9908) States connected to redis: 127.0.0.1:9000
                    2020-02-21 21:29:38.292 - debug: modbus.0 (9908) statesDB connected
                    2020-02-21 21:29:38.597 - info: sql.0 (1474) enabled logging of modbus.0.info.connection, Alias=false
                    2020-02-21 21:29:38.635 - info: modbus.0 (9908) starting. Version 3.0.0 in /opt/iobroker/node_modules/iobroker.modbus, node: v10.18.1
                    2020-02-21 21:29:38.922 - info: sql.0 (1474) disabled logging of modbus.0.info.pollTime
                    2020-02-21 21:29:39.475 - debug: modbus.0 (9908) connect to serial /dev/ttyUSB0 with 9600
                    2020-02-21 21:29:39.493 - info: modbus.0 (9908) Connected to slave
                    2020-02-21 21:29:39.496 - debug: modbus.0 (9908) Poll device 1
                    2020-02-21 21:29:39.500 - debug: modbus.0 (9908) Poll holdingRegs DevID(1) address 30001 - 2 bytes
                    2020-02-21 21:29:39.534 - error: modbus.0 (9908) Wrong CRC for frame: 0,1,3,4,0,0,0,0
                    2020-02-21 21:29:44.508 - warn: modbus.0 (9908) Error: undefined
                    2020-02-21 21:29:44.509 - error: modbus.0 (9908) Request timed out.
                    2020-02-21 21:29:44.512 - warn: modbus.0 (9908) Poll error count: 1 code: {"err":"timeout"}
                    2020-02-21 21:29:45.513 - info: modbus.0 (9908) Disconnected from slave
                    2020-02-21 21:29:45.521 - debug: modbus.0 (9908) Clearing timeout of the current request.
                    2020-02-21 21:29:45.523 - debug: modbus.0 (9908) Cleaning up request fifo.

                    wendy2702 1 Reply Last reply Reply Quote 0
                    • wendy2702
                      wendy2702 @panki2 last edited by

                      @panki2 sagte in Stromzähler B+G E-Tech SDM630Modbus V2 via RS 485 /USB ?:

                      Wrong CRC for frame: 0,1,3,4,0,0,0,0

                      Ich denke „Float Big Endian“ ist nicht richtig.

                      Da solltest du mal von oben nach unten durch probieren. Ich weiß das es lästig ist aber wenn es nicht in der Anleitung steht und es im Netzt keine weitere Info gibt wird wohl kein weg daran vorbei führen.

                      P 1 Reply Last reply Reply Quote 0
                      • P
                        panki2 last edited by

                        Ich fange damit leider nicht viel an:
                        Vielleicht hilft es einem FAchmann weiter
                        modbus protokoll SDM630V2
                        https://bg-etech.de/download/manual/SDM630Register1-5.pdf

                        1 Reply Last reply Reply Quote 0
                        • P
                          panki2 @wendy2702 last edited by

                          @wendy2702 said in Stromzähler B+G E-Tech SDM630Modbus V2 via RS 485 /USB ?:

                          Da solltest du mal von oben nach unten durch probieren.

                          Was schreibe ich bei Faktor, Länge und Offset rein?

                          1 Reply Last reply Reply Quote 0
                          • wendy2702
                            wendy2702 last edited by

                            Faktor und Offset sind erstmal uninteressant.

                            Länge 1 oder 2 ohne in das PDF geschaut zu haben.

                            Ist je nach Einstellung (Float, Signed. Etc) aber eh fest gelegt.

                            1 Reply Last reply Reply Quote 0
                            • P
                              panki2 last edited by

                              Ich habe jetzt alle float, endian von oben nach unten usw durch.
                              ..geändert,
                              grüner Haken und
                              Speichern und dann in putty geschaut. immer wrong CRC....

                              1 Reply Last reply Reply Quote 0
                              • wendy2702
                                wendy2702 last edited by wendy2702

                                Float Big Endian mal mit Länge 2 versucht?

                                Bin nur am IPad und kann selber nicht schauen bei mir.

                                P 1 Reply Last reply Reply Quote 0
                                • P
                                  panki2 @wendy2702 last edited by

                                  @wendy2702 said in Stromzähler B+G E-Tech SDM630Modbus V2 via RS 485 /USB ?:

                                  Float Big Endian mal mit Länge 2 versucht?

                                  Ja, Länge 2
                                  Value ist richtig bei "Rolle"?

                                  1 Reply Last reply Reply Quote 0
                                  • wendy2702
                                    wendy2702 last edited by

                                    Value passt.

                                    Hast du auch Float BIG Endian Byte und Word Swap probiert?

                                    P 1 Reply Last reply Reply Quote 0
                                    • P
                                      panki2 @wendy2702 last edited by panki2

                                      @wendy2702 said in Stromzähler B+G E-Tech SDM630Modbus V2 via RS 485 /USB ?:

                                      Hast du auch Float BIG Endian Byte und Word Swap probiert?
                                      Ich habe alle von oben nach unten durchexerziert...
                                      aber auf Länge usw nicht geachtet

                                      wendy2702 1 Reply Last reply Reply Quote 0
                                      • wendy2702
                                        wendy2702 @panki2 last edited by

                                        @panki2 ich schaue mal ins PDF...

                                        Nur leider heute nicht mehr.

                                        P 1 Reply Last reply Reply Quote 0
                                        • P
                                          panki2 @wendy2702 last edited by

                                          @wendy2702
                                          Ok, lieb von Dir. Ist egal, es kommt da uf einen Tag nicht drauf an.
                                          Ich spiel dann mal mit den anderen adaptern rum. Wetterstation, google home usw. Da tut wenigstens etwas..
                                          Also vielen DAnk für Deine Mühe bisher...

                                          1 Reply Last reply Reply Quote 0
                                          • wendy2702
                                            wendy2702 last edited by wendy2702

                                            Hier https://wiki.volkszaehler.org/hardware/channels/meters/power/eastron_sdm630_modbus

                                            Gibt es noch einen Hinweis zum BUS. Pull UP/Down und Abschluß erforderlich.

                                            Auch sind die Anschlüsse wohl verdreht.

                                            Hier mal lesen und scrollen. Steht auch mit Bild etwas bezüglich BUS Anbindung:

                                            https://github.com/gonium/gosdm630

                                            P 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            523
                                            Online

                                            31.8k
                                            Users

                                            80.0k
                                            Topics

                                            1.3m
                                            Posts

                                            modbus adapter sdm630
                                            11
                                            144
                                            26137
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo