    This topic has been deleted. Only users with topic management privileges can see it.
    • siggi85
      siggi85 @Travin last edited by siggi85

      @Travin sagte in [Adapter] Shelly Adapter mit MQTT:

      • dort die IP und den Port des Iobrokers eingegeben (unter "Server")

      Den Port der Weboberfläche oder den des Shelly Adapters (also des MQTT Servers)?! Der Port der Weboberfläche ist der falsche.

      1 Reply Last reply Reply Quote 0
      • T
        Travin last edited by

        23a100a0-b64d-4a3a-92c6-572460079f1d-image.png

        13acd323-005e-433a-b642-96c746398681-image.png

        Stuebi 1 Reply Last reply Reply Quote 0
        • Stuebi
          Stuebi @Travin last edited by

          @Travin , dwie ist die IP Adresse von ioBroker? Und warum hast du Port 8081 eingestellt? Und warum hast du denn Präfix MQTT deaktiviert.

          1 Reply Last reply Reply Quote 0
          • T
            Travin last edited by

            ja, das ist die Iobroker IP. Port 8081 ist der Port des Iobrokers. Sollte ich das nicht so einstellen???
            Welchen dann? einen beliebigen, nicht genutzten?
            MQTT Präfix... weiß nicht warum🤷‍♂️ 🤦‍♂️

            Stuebi 1 Reply Last reply Reply Quote 0
            • Stuebi
              Stuebi @Travin last edited by

              @Travin , eigentlich ist der Standardport für MQTT 1882. Wenn du den nicht vergeben hast z.B. durch den MQTT Adapter nimm den.

              1 Reply Last reply Reply Quote 0
              • T
                Travin last edited by

                Ahhh, siehe da, es werde Licht 🙂

                Vielen Dank! Sorry das ich mich ein wenig doof angestellt habe. Bin noch recht unerfahren auf dem Gebiet...

                TOP Support 😉

                Stuebi 1 Reply Last reply Reply Quote 0
                • Stuebi
                  Stuebi @Travin last edited by

                  @Travin , super das es jetzt funktioniert. Viel Spass noch mit de Shelly Adapter!

                  1 Reply Last reply Reply Quote 0
                  • P
                    passuff last edited by

                    erstmal vielen Dank fürden super Adapter.
                    Lieder habe ich gerade einen Bug gefunden:
                    Ich habe einen Shelly 2.5 als Rolladenaktor in Gebrauch. Leider habe ich beim Einbau die den Motor falsch herum angeklemmt, sodass der Rolladen beim klick auf close hochfährt und umgekehrt.
                    Glücklicherweise gibt es im Shelly Menü eine Richtungsumkehr, welche jedoch keinerlei Auswirkung auf den "state" im iobroker hat.
                    Ich werde den Schalter jetzt neu verdrahten, würde es aber begrüßen, wenn man das im Adapter fixen könnte. Habe auch ein github issue eröffnet.

                    Gruß

                    1 Reply Last reply Reply Quote 0
                    • N
                      NetFritz last edited by

                      Hallo
                      Ich benutze einen Shelly 1PM .
                      Der Kontakt Eingang ist auf Detached eingestellt, dort habe ich einen Endschalter angebaut.

                      Den möchte ich jetzt in ioBroker mit dem Shelly-Adapter abfragen.
                      Dazu habe ich mqtt im Shelly und auf dem shelly-Adapter eingestellt.
                      Ich bekomme im Log immer noch eine Fehlermeldung, obwohl der Adapter
                      grün ist und auch wenn ich auf der Shelly-Webseite unter mqtt abspeichere
                      der grüne Balken kommt.

                      shelly.0	2020-04-03 11:13:11.627	info	(16428) Destroy 192.168.2.204 (shelly1pm / shelly1pm-8CAAB5060719 / SHSW-PM#8CAAB5060719#1)
                      shelly.0	2020-04-03 11:13:11.625	info	(16428) Close Client: 192.168.2.204 (shelly1pm / shelly1pm-8CAAB5060719 / SHSW-PM#8CAAB5060719#1) (false)
                      shelly.0	2020-04-03 11:13:11.462	error	(16428) Wrong MQTT authentification for : 192.168.2.204 (shelly1pm / shelly1pm-8CAAB5060719 / SHSW-PM#8CAAB5060719#1)
                      shelly.0	2020-04-03 11:12:55.264	info	(16428) Starting Shelly adapter in MQTT modus. Listening on 0.0.0.0:1882
                      shelly.0	2020-04-03 11:12:54.967	info	(16428) starting. Version 3.1.6 in /opt/iobroker/node_modules/iobroker.shelly, node: v10.18.0
                      shelly.0	2020-04-03 11:12:47.538	info	(16293) Terminated (START_IMMEDIATELY_AFTER_STOP): Without reason
                      shelly.0	2020-04-03 11:12:47.536	info	(16293) terminating
                      shelly.0	2020-04-03 11:12:47.534	info	(16293) Closing Adapter
                      shelly.0	2020-04-03 11:12:47.531	info	(16293) Got terminate signal TERMINATE_YOURSELF
                      

                      shellymqtt1.png

                      shellymqtt2.png
                      Wie bekomme ich die Fehlermeldung weg?
                      Gruß NetFritz

                      1 Reply Last reply Reply Quote 0
                      • N
                        NetFritz last edited by

                        Hallo
                        Hat sich erledigt.
                        Habe nochmal Username und Password neu eingegeben.
                        Hatte ich schon mehrmals gemacht.
                        Jetzt geht es.
                        Gruß NetFritz

                        E 1 Reply Last reply Reply Quote 0
                        • E
                          e-s @NetFritz last edited by

                          @NetFritz
                          Vorher stand einmal netfritz und einmal NetFritz, das ist schon ein komplett anderer User.

                          1 Reply Last reply Reply Quote 0
                          • N
                            NetFritz last edited by

                            Hallo
                            Das hatte nach den Snapshot auch gesehen, hatte ich dann verbessert.
                            Das Problem war wahrscheinlich, wenn man auf der Shelly-Webseite
                            den User ändert und abspeichert dann ist manchmal der alter User immer
                            noch drin.
                            Jetzt ist Input auch drin.
                            Gruß NetFritz

                            1 Reply Last reply Reply Quote 0
                            • FoodFighter
                              FoodFighter last edited by FoodFighter

                              Hallo,
                              ich muss jetzt mal nachfragen, weil mir einiges nicht ganz klar ist.
                              Zum Setup: ich nutze iobroker in einem Docker-Container (Bridge-Mode) , daher kommt mir die MQTT-Einstellung des Adapters sehr gelegen.
                              Weiterhin nutze ich einen Moquitto MQTT Broker in einem weiterem Container auf Port 1883 (Standart). Über diesen laufen auch diverse andere MQTT-Geräte.

                              Wenn ich nun alles richtig verstehe, macht der Shelly-Adapter einen eigenen MQTT-Server auf, sobald man MQTT aktiviert (default auf Port 1882).

                              Es ist also nicht möglich die Shellies alle an einen bestehenden Broker senden zu lassen (in meinem falle Mosquitto) und gleichzeitig den Shelly-Adapter mit der MQTT Funktion zu nutzen - sehe ich das richtig?

                              Ich möchte die Shellys weiterhin an Mosquitto senden lassen, da diese Daten u.U. noch von anderen Containern außer ioBroker verwendet werden sollen.
                              Wenn ich dem Shelly-Adapter nun einfach Port 1883 zuweise und ihm das gleichen MQTT-User+Pwd zuweise, kommen keine Ergebnisse an. (Vermutlich weil der Port 1883 schon dem Mosquitto-Container zugewiesen ist).

                              Ist es denn nicht möglich, dass sich dieser Shelly-Adapter die Daten einfach aus dem mqtt-client-Adapter raus zieht, welcher die Daten ja erfolgreich beim MQTT-Broker abholt? (Falls nein, wieso nicht?)

                              [Edit]
                              Bzw. wäre es machbar die Einstellungen derart zu erweitern, dass man den Shelly-Adapter zwischen MQTT-Server und Client umschalten könnte, für diejenigen, die den mqtt-client ohnehin schon für andere Geräte nutzen?
                              [/Edit]

                              COAP fällt in meinem Falle flach, wegen der Bridge-Einstellung, die ich so auch gerne beibehalten würde.

                              Den Shelly-Adapter würde ich jedoch gerne zusätzlich zum bestehenden Mosquitto nutzen, da dieser Adapter doch einige Funktionen bietet, die das Arbeiten mit den Shellys in iobroker deutlich vereinfachen.

                              [Edit]
                              Was mir auch noch unklar scheint -> wenn man die Shellys per MQTT auf den Shelly-Adapter senden lässt, wird scheinbar die custom-MQTT-Prefix, die man im Shelly hinterlegt, ignoriert - ist das gewollt?

                              Für Dumme steht es sogar in der github-repo, dass die Präfix nicht angepackt werden darf...

                              D 1 Reply Last reply Reply Quote 1
                              • M
                                maxpd last edited by

                                Hallo,

                                mein Shelly Adapter (3.1.6) startet ständig neu. Ich habe 3 Shelly Devices im Einsatz.

                                shelly.0	2020-04-12 06:36:08.655	info	(4720) Shelly device 192.168.178.40 (shelly1 / shelly1-93F1CA / SHSW-1#93F1CA#1) with CoAP connected!
                                shelly.0	2020-04-12 06:36:02.254	info	(4720) Listening for Shelly packets in the network
                                shelly.0	2020-04-12 06:36:02.173	info	(4720) Starting Shelly adapter in CoAP modus.
                                shelly.0	2020-04-12 06:36:02.121	info	(4720) starting. Version 3.1.6 in /opt/iobroker/node_modules/iobroker.shelly, node: v10.19.0
                                shelly.0	2020-04-12 06:35:30.183	error	(4369) Error handling Shelly data: Error: No reply in 247s
                                
                                
                                
                                shelly.0	2020-04-12 06:31:31.281	info	(4369) Shelly device 192.168.178.112 (shellyswitch25 / shellyswitch25-740842 / SHSW-25#740842#1) with CoAP connected!
                                shelly.0	2020-04-12 06:31:22.698	info	(4369) Shelly device 192.168.178.40 (shelly1 / shelly1-93F1CA / SHSW-1#93F1CA#1) with CoAP connected!
                                shelly.0	2020-04-12 06:31:17.451	info	(4369) Listening for Shelly packets in the network
                                shelly.0	2020-04-12 06:31:17.372	info	(4369) Starting Shelly adapter in CoAP modus.
                                shelly.0	2020-04-12 06:31:17.321	info	(4369) starting. Version 3.1.6 in /opt/iobroker/node_modules/iobroker.shelly, node: v10.19.0
                                shelly.0	2020-04-12 06:30:45.162	error	(3991) Error handling Shelly data: Error: No reply in 247s
                                shelly.0	2020-04-12 06:31:31.281	info	(4369) Shelly device 192.168.178.112 (shellyswitch25 / shellyswitch25-740842 / SHSW-25#740842#1) with CoAP connected!
                                shelly.0	2020-04-12 06:31:22.698	info	(4369) Shelly device 192.168.178.40 (shelly1 / shelly1-93F1CA / SHSW-1#93F1CA#1) with CoAP connected!
                                shelly.0	2020-04-12 06:31:17.451	info	(4369) Listening for Shelly packets in the network
                                shelly.0	2020-04-12 06:31:17.372	info	(4369) Starting Shelly adapter in CoAP modus.
                                shelly.0	2020-04-12 06:31:17.321	info	(4369) starting. Version 3.1.6 in /opt/iobroker/node_modules/iobroker.shelly, node: v10.19.0
                                shelly.0	2020-04-12 06:30:45.162	error	(3991) Error handling Shelly data: Error: No reply in 247s
                                shelly.0	2020-04-12 06:26:51.526	info	(3991) Shelly device 192.168.178.40 (shelly1 / shelly1-93F1CA / SHSW-1#93F1CA#1) with CoAP connected!
                                shelly.0	2020-04-12 06:26:45.896	info	(3991) Shelly device 192.168.178.112 (shellyswitch25 / shellyswitch25-740842 / SHSW-25#740842#1) with CoAP connected!
                                shelly.0	2020-04-12 06:26:38.111	info	(3991) Listening for Shelly packets in the network
                                shelly.0	2020-04-12 06:26:38.028	info	(3991) Starting Shelly adapter in CoAP modus.
                                shelly.0	2020-04-12 06:26:37.960	info	(3991) starting. Version 3.1.6 in /opt/iobroker/node_modules/iobroker.shelly, node: v10.19.0
                                shelly.0	2020-04-12 06:26:32.701	info	(3967) Terminated (START_IMMEDIATELY_AFTER_STOP): Without reason
                                shelly.0	2020-04-12 06:26:32.700	info	(3967) terminating
                                shelly.0	2020-04-12 06:26:32.699	info	(3967) Closing Adapter
                                shelly.0	2020-04-12 06:26:32.697	info	(3967) Got terminate signal TERMINATE_YOURSELF
                                shelly.0	2020-04-12 06:26:32.523	info	(3967) Listening for Shelly packets in the network
                                shelly.0	2020-04-12 06:26:32.446	info	(3967) Starting Shelly adapter in CoAP modus.
                                shelly.0	2020-04-12 06:26:32.391	info	(3967) starting. Version 3.1.6 in /opt/iobroker/node_modules/iobroker.shelly, node: v10.19.0
                                

                                06638fe6-9a46-40c0-bda5-cb71d77a4a04-image.png

                                df0c3e3a-e8c7-4e75-b9a8-c12d96b87ccf-image.png

                                8fa36ba6-b0d5-428b-b9ac-f0df5b2ccbdf-image.png

                                Stuebi 1 Reply Last reply Reply Quote 0
                                • Stuebi
                                  Stuebi @maxpd last edited by

                                  @maxpd , siehe hier https://forum.iobroker.net/topic/26110/test-adapter-shelly-v3-1-x/67
                                  Eine Lösung gibt es aber nicht

                                  M 1 Reply Last reply Reply Quote 0
                                  • M
                                    maxpd @Stuebi last edited by

                                    @Stuebi danke dir.
                                    Bis zu welcher Version lief es denn, dann downgrade ich dort hin.

                                    Stuebi 1 Reply Last reply Reply Quote 0
                                    • Stuebi
                                      Stuebi @maxpd last edited by

                                      @maxpd , da hilft kein downgrade. Meistens verschwindet der Fehler irgendwann wieder.

                                      M 1 Reply Last reply Reply Quote 0
                                      • M
                                        maxpd @Stuebi last edited by

                                        @Stuebi Ok, leider reagieren die Aktoren oft nicht. Das heißt ich muss von COAP zu MQTT wechseln.

                                        1 Reply Last reply Reply Quote 1
                                        • D
                                          Diggewuff @FoodFighter last edited by

                                          @FoodFighter said in [Adapter] Shelly Adapter mit MQTT:

                                          Hallo,
                                          ich muss jetzt mal nachfragen, weil mir einiges nicht ganz klar ist.
                                          Zum Setup: ich nutze iobroker in einem Docker-Container (Bridge-Mode) , daher kommt mir die MQTT-Einstellung des Adapters sehr gelegen.
                                          Weiterhin nutze ich einen Moquitto MQTT Broker in einem weiterem Container auf Port 1883 (Standart). Über diesen laufen auch diverse andere MQTT-Geräte.

                                          Wenn ich nun alles richtig verstehe, macht der Shelly-Adapter einen eigenen MQTT-Server auf, sobald man MQTT aktiviert (default auf Port 1882).

                                          Es ist also nicht möglich die Shellies alle an einen bestehenden Broker senden zu lassen (in meinem falle Mosquitto) und gleichzeitig den Shelly-Adapter mit der MQTT Funktion zu nutzen - sehe ich das richtig?

                                          Ich möchte die Shellys weiterhin an Mosquitto senden lassen, da diese Daten u.U. noch von anderen Containern außer ioBroker verwendet werden sollen.
                                          Wenn ich dem Shelly-Adapter nun einfach Port 1883 zuweise und ihm das gleichen MQTT-User+Pwd zuweise, kommen keine Ergebnisse an. (Vermutlich weil der Port 1883 schon dem Mosquitto-Container zugewiesen ist).

                                          Ist es denn nicht möglich, dass sich dieser Shelly-Adapter die Daten einfach aus dem mqtt-client-Adapter raus zieht, welcher die Daten ja erfolgreich beim MQTT-Broker abholt? (Falls nein, wieso nicht?)

                                          [Edit]
                                          Bzw. wäre es machbar die Einstellungen derart zu erweitern, dass man den Shelly-Adapter zwischen MQTT-Server und Client umschalten könnte, für diejenigen, die den mqtt-client ohnehin schon für andere Geräte nutzen?
                                          [/Edit]

                                          COAP fällt in meinem Falle flach, wegen der Bridge-Einstellung, die ich so auch gerne beibehalten würde.

                                          Den Shelly-Adapter würde ich jedoch gerne zusätzlich zum bestehenden Mosquitto nutzen, da dieser Adapter doch einige Funktionen bietet, die das Arbeiten mit den Shellys in iobroker deutlich vereinfachen.

                                          [Edit]
                                          Was mir auch noch unklar scheint -> wenn man die Shellys per MQTT auf den Shelly-Adapter senden lässt, wird scheinbar die custom-MQTT-Prefix, die man im Shelly hinterlegt, ignoriert - ist das gewollt?

                                          Für Dumme steht es sogar in der github-repo, dass die Präfix nicht angepackt werden darf...

                                          Ich würde auch gerne meinen bereits vorhandenen MQTT Broker verwenden. Kann der Adapter sich nicht einfach zu diesem subscriben?

                                          E 1 Reply Last reply Reply Quote 0
                                          • E
                                            e-s @Diggewuff last edited by

                                            @Diggewuff
                                            Du kannst doch direkt alles an einen eigenen mqtt schicken und den Adapter weglassen.

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate
                                            FAQ Cloud / IOT
                                            HowTo: Node.js-Update
                                            HowTo: Backup/Restore
                                            Downloads
                                            BLOG

                                            968
                                            Online

                                            31.6k
                                            Users

                                            79.4k
                                            Topics

                                            1.3m
                                            Posts

                                            mqtt shelly
                                            43
                                            213
                                            40687
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo