    This topic has been deleted. Only users with topic management privileges can see it.
    • MassiveAttack
      MassiveAttack last edited by MassiveAttack

      im browser wird mir das aber schon angezeigt, zB

      "Hc1HeatCurve": {
      "name": "Hc1HeatCurve",
      "passive": false,
      "write": false,
      "lastup": 0

      iobroker hat aber keinen DP erstellt, und wenn ich den extra pollen möchte, kommt eben der fehler. also er existiert, kann aber nicht abgefragt werden.

      befindet sich in 700.messages.Hc1HeatCurve

      Die Multimatic Fachhandwerkebene sowie die WP selbst sind doch mit codes geschützt, liegt es vielleicht daran dass man diese values nicht abfragen kann/darf?? wie kann man das dann umgehen?

      bei einigen DP kommt im telnet der fehler: ERR arbitration lost
      outsidetemp liefert einen wert (liegt unter broadcast)
      Hc1FlowTemp liefert einen fehler (liegt unter 700)

      Hiltex 1 Reply Last reply Reply Quote 0
      • Hiltex
        Hiltex @MassiveAttack last edited by

        @MassiveAttack Dass dieser Datenpunkt im Browser auftaucht liegt daran, dass er im Config-File vorhanden ist. Das bedeutet jedoch nicht zwangsläufig, dass dein Gerät diesen auch kennt - daher kommt sicherlich auch der Fehler. Wie ich zuvor angedeutet hatte, sind die Datenpunkte/Config-Files zumeist per Reserve-Engineering entstanden. Wahrscheinlich war dieser Datenpunkt bei demjenigen vorhanden, der das Config-File erstellt hat. Vorstellbar wäre, dass dein Regler eine andere Firmware besitzt und dieser Datenpunkt nicht mehr vorhanden ist, oder aber einen anderen Namen hat.

        Mein VRC700 kennt zum Beispiel den Datenpunkt z1Name2 nicht, obwohl er im Config-File vorhanden ist, Hc1HeatCurve allerdings schon.

        Ich meine oben gelesen zu haben, dass du garkeinen VRC700 besitzt. Da ist natürlich von vornherein ein gewisses Gap zwischen Config-Files und tatsächlich vorhandenen Datenpunkten zu erwarten.

        In meinen Ausführungen ist viel hätte, könnte und wäre enthalten. Das liegt einfach daran, dass ich kein Profi bin, was das Thema ebus angeht. Allerdings hatte ich mich anfangs auch über viele Sachen gewundert und hab im Trüben gefischt, aber irgendwann wird es klarer.

        Du kannst dir ja mal die Mühe machen und alle Datenpunkte aus dem Browser per ebus abzufragen (copy&paste, im Texteditor von Unrat befeien und im ebus-Adapter eintragen). So hatte ich das anfangs gemacht und recht schnell einen überblick bekommen, welche Werte meine Therme liefert.

        Den Code für die Fachhandwerkerebene kann man übrigens ebenfalls per eBus auslesen. Der Datenpunkt heißt bei mir KeyCodeforConfigMenu. Die Datenpunkte lassen sich auch auslesen, wenn dir dieser Code bisher unbekannt war. Das hat also nichts miteinander zu tun.

        1 Reply Last reply Reply Quote 0
        • MassiveAttack
          MassiveAttack last edited by

          ebusctl info liefert folgendes:

          ebusctl info

          version: ebusd 3.4.v3.3-51-g57eae05
          access: *
          signal: acquired
          symbol rate: 97
          max symbol rate: 177
          reconnects: 0
          masters: 5
          messages: 421
          conditional: 0
          poll: 0
          update: 8
          address 00: master #1
          address 03: master #11
          address 08: slave #11
          address 10: master #2
          address 15: slave #2, scanned "MF=Vaillant;ID=70000;SW=0509;HW=6403", loaded "vaillant/15.700.csv"
          address 26: slave
          address 31: master #8, ebusd
          address 36: slave #8, ebusd
          address 71: master #9
          address 76: slave #9

          vaillant/15.700.csv kann ich aber nirgendwo editieren. wird das nicht lokal gespeichert? unter /etc/ebusd finde ich nichts.
          wenn ich mir ältere (2.1.1) ebusd-configs runterlade, finde ich dieses csv auch nicht

          doch ich habe eine VRC700. ich habe auch testweise ein paar DP aus dem browser kopiert und im ebus adapter eingetragen, jedoch bekomme ich dann einen fehler (timeout) siehe oben weiter

          ich kenne natürlich die codes, wollte nur wissen ob diese menüpunkte vom ebus auch ohne ausgelesen werden können, ok.

          ich vermute es hat was mit den config files. werden die nicht lokal abgelegt, und bei einem update überschrieben? wie wird das zyklisch geprüft? was ist der unterschied zwischen "scanconfig" und "scanconfig=full"?

          meine aktuelle config:
          -f --scanconfig=full -d 192.168.0.65:5000 -n --latency=80000 -p 8888 --configpath=http://ebusd.eu/config/ -l /var/log/ebusd.log --accesslevel=* --httpport=8889

          Hiltex 1 Reply Last reply Reply Quote 0
          • Hiltex
            Hiltex @MassiveAttack last edited by

            @MassiveAttack Mit deinen Startparametern werden die notwendigen Config-Files aus dem Internet geladen. Wenn du das ändern möchtest solltest du mal die zugegebenermaßen nicht besonders leicht verständliche Dokumentation von ebusd bei Github konsultieren.

            1 Reply Last reply Reply Quote 0
            • MassiveAttack
              MassiveAttack last edited by

              naja happy bin ich mit dem ganzen noch nicht. ich bekomme zwar viele DPs in iobroker geladen, jedoch nicht alle (für mich) relevanten.

              weiters habe ich das problem, dass nur werte unter "broadcast" von selbst aktualisiert werden, alle anderen aktualisieren sich einfach nicht, außer ich frage diese (zB mit der vaillant app) ab. das macht statistiken und auswertungen überflüssig.
              wie kann man updates triggern?

              sobald ich einen DP in der ebus liste zum aktiven pollen eintrage, bekomme ich ein timeout. egal ob er bereits als DP existiert, oder nicht.

              Hiltex 1 Reply Last reply Reply Quote 0
              • Hiltex
                Hiltex @MassiveAttack last edited by

                @MassiveAttack sagte in Adapter: ebus:

                wie kann man updates triggern?

                Indem du sie in den Adapter-Einstellungen -> Tab EBUSD -> im Feld Komma-getrennte Liste von abgefragten Datenpunkten einträgst.
                Etwa so:
                DisplayedOutsideTemp,SolarYieldTotal,z1ActualRoomTempDesired,FlowTemp,ReturnTemp,FlowTempDesired,HwcStorageTemp,StorageTemp,StorageExitTemp,HwcTemp

                @MassiveAttack sagte in Adapter: ebus:

                sobald ich einen DP in der ebus liste zum aktiven pollen eintrage, bekomme ich ein timeout. egal ob er bereits als DP existiert, oder nicht.

                Funktioniert die Abfrage denn auf der Kommandozeile oder kommt da auch ein Timeout?

                MassiveAttack 1 Reply Last reply Reply Quote 0
                • MassiveAttack
                  MassiveAttack @Hiltex last edited by

                  @Hiltex
                  funktioniert auch nur bei allen DPs unter "broadcast".
                  read -c 700 Hc1FlowTemp liefert: ERR arbitration lost (-f geht auch nicht)

                  woran kann das liegen? berechtigungsproblem?

                  1 Reply Last reply Reply Quote 0
                  • MassiveAttack
                    MassiveAttack last edited by

                    btw, wenn ich ein "listen -u" mache, kommen unzählige codierte messages, vermutlich die die auch suche 🙂
                    zB: 1026b5230f05ff0000000000ffff000000000000 0101
                    wie könnte man diese decoden?

                    1 Reply Last reply Reply Quote 0
                    • Timmerx
                      Timmerx last edited by

                      Hallo Leute,

                      ich konnte mich jetzt auch nochmal um meine Wärmepumpe VW117/4 mit EBus kümmern.
                      Ich habe es schon letztes Jahr geschafft einige Daten auszulesen , wie z.B Hz Vorlauftemperatur, Hz Rücklauftemperatur und Aussentemperatur diese Werte werde mir vom Ebus Adapter dirket angezeit ( ich brauch dafür nix in der Liste "Komma getrennte Liste aller Datenpunktnamen" eintragen)

                      Jetzt würde mich allerdings würden mich jetzt auch brennent weitere Daten interessieren, z.B. SoleVorlauf, SoleRücklauf, Integrall, HzPumpendrehzahl, Mischerstellung, momentane Leistung, Tageswerte, Wochenwerte....

                      Ich habe es bis jetzt noch nicht hinbekommen auch nur einen Werte (mal völlig egal welche) über "Komma getrennte Liste aller Datenpunktnamen" abzufragen.

                      HIer mal mein Log vom IObroker,

                      ebus.2
                      2020-04-26 09:09:02.743
                      info
                      (17411) Terminated (NO_ERROR): Without reason
                      ebus.2
                      2020-04-26 09:09:02.742
                      info
                      (17411) all history done (exit)
                      ebus.2
                      2020-04-26 09:09:02.741
                      debug
                      (17411) delete
                      ebus.2
                      2020-04-26 09:09:02.739
                      debug
                      (17411) delete
                      ebus.2
                      2020-04-26 09:09:02.690
                      info
                      (17411) all http done
                      ebus.2
                      2020-04-26 09:09:02.667
                      debug
                      (17411) no update since 25.4.2020 14:51:2 hmu.messages.YieldTotal.lastup 
                      ebus.2
                      2020-04-26 09:09:02.587
                      debug
                      (17411) request data from http://192.168.178.84:8891/data
                      ebus.2
                      2020-04-26 09:09:02.586
                      debug
                      (17411) all telnet done 
                      ebus.2
                      2020-04-26 09:09:02.583
                      error
                      (17411) received ERR: element not found for FlowTempMax
                      ebus.2
                      2020-04-26 09:09:02.580
                      error
                      (17411) received ERR: element not found for HwcStarts
                      ebus.2
                      2020-04-26 09:09:02.577
                      error
                      (17411) received ERR: element not found for HcStarts
                      ebus.2
                      2020-04-26 09:09:02.575
                      error
                      (17411) received ERR: element not found for HwcHours
                      ebus.2
                      2020-04-26 09:09:02.572
                      error
                      (17411) received ERR: element not found for HcHours
                      ebus.2
                      2020-04-26 09:09:02.569
                      error
                      (17411) received ERR: element not found for Wasserdruck
                      ebus.2
                      2020-04-26 09:09:02.567
                      error
                      (17411) received ERR: element not found for WaterPressure
                      ebus.2
                      2020-04-26 09:09:02.564
                      error
                      (17411) received ERR: element not found for ACRoomthermostat
                      ebus.2
                      2020-04-26 09:09:02.561
                      error
                      (17411) received ERR: element not found for HwcTemp
                      ebus.2
                      2020-04-26 09:09:02.559
                      error
                      (17411) received ERR: element not found for StorageExitTemp
                      ebus.2
                      2020-04-26 09:09:02.556
                      error
                      (17411) received ERR: element not found for StorageTemp
                      ebus.2
                      2020-04-26 09:09:02.553
                      error
                      (17411) received ERR: element not found for HwcStorageTemp
                      ebus.2
                      2020-04-26 09:09:02.550
                      error
                      (17411) received ERR: element not found for FlowTempDesired
                      ebus.2
                      2020-04-26 09:09:02.548
                      error
                      (17411) received ERR: element not found for ReturnTemp
                      ebus.2
                      2020-04-26 09:09:02.545
                      error
                      (17411) received ERR: element not found for FlowTemp
                      ebus.2
                      2020-04-26 09:09:02.542
                      error
                      (17411) received ERR: element not found for z1ActualRoomTempDesired
                      ebus.2
                      2020-04-26 09:09:02.539
                      error
                      (17411) received ERR: element not found for SolarYieldTotal
                      ebus.2
                      2020-04-26 09:09:02.536
                      error
                      (17411) received ERR: element not found for DisplayedOutsideTemp
                      ebus.2
                      2020-04-26 09:09:02.082
                      debug
                      (17411) telnet connected
                      ebus.2
                      2020-04-26 09:09:02.074
                      debug
                      (17411) connect telnet to IP 192.168.178.84 port 8888
                      ebus.2
                      2020-04-26 09:09:02.073
                      debug
                      (17411) to poll ctr 18 vals: DisplayedOutsideTemp,SolarYieldTotal,z1ActualRoomTempDesired,FlowTemp,ReturnTemp,FlowTempDesired,HwcStorageTemp,StorageTemp,StorageExitTemp,HwcTemp,ACRoomthermostat,Water
                      ebus.2
                      2020-04-26 09:09:02.046
                      debug
                      (17411) init common variables 
                      ebus.2
                      2020-04-26 09:09:02.044
                      debug
                      (17411) init variables 
                      ebus.2
                      2020-04-26 09:09:02.044
                      debug
                      (17411) start with interface ebusd 
                      ebus.2
                      2020-04-26 09:09:02.043
                      debug
                      (17411) set timeout to 180 sec
                      ebus.2
                      2020-04-26 09:09:02.015
                      info
                      (17411) starting. Version 1.0.0 in /opt/iobroker/node_modules/iobroker.ebus, node: v10.17.0
                      ebus.2
                      2020-04-26 09:08:02.836
                      info
                      (17372) Terminated (NO_ERROR): Without reason
                      ebus.2
                      2020-04-26 09:08:02.834
                      info
                      (17372) all history done (exit)
                      

                      Ich hoff mir kann wer helfen, die Abfragen hin zubekommen

                      MassiveAttack 1 Reply Last reply Reply Quote 0
                      • MassiveAttack
                        MassiveAttack @Timmerx last edited by

                        @Timmerx
                        ich habe das gleiche problem, anscheinend gibt es für diese (verschlüsselten) elemente noch kein entschlüsseltes csv

                        werden bei dir die anderen elemente automatisch aktualisiert im iobroker? bei mir leider nicht, nur die werte die unter broadcast zu finden sind. die anderen werden nur dann aktualisert, wenn ich diese zB mit der vaillant app abrufe.
                        wie machst du das?

                        1 Reply Last reply Reply Quote 0
                        • Timmerx
                          Timmerx last edited by

                          HI,

                          ja es werden alle Werte automatisch aktualisiert.
                          Unter Broadcast gibt es bei mir nur den Wert "outsidetemp" der wird auch automatisch aktualisiert, den wert habe ich aber nicht manuell im EBus Adapter eingetragen, wo kommt der her?

                          Wie kann ich die csv bearbeiten?

                          Hiltex 1 Reply Last reply Reply Quote 0
                          • Hiltex
                            Hiltex @Timmerx last edited by

                            @Timmerx sagte in Adapter: ebus:

                            Unter Broadcast gibt es bei mir nur den Wert "outsidetemp" der wird auch automatisch aktualisiert, den wert habe ich aber nicht manuell im EBus Adapter eingetragen, wo kommt der her?

                            Die Werte unter Broadcast werden ohne Abfrage einfach von der Theme/WP an alle Busteilnehmer gesendet und entsprechend auch in ioBroker angezeigt. Meines Wissens nach kann man dieses Verhalten nicht beeinflussen.

                            Wie man unbekannte Werte entschlüsselt ist in der Doku von ebusd beschrieben, zu finden im Github Repository

                            Timmerx Rene_HM 2 Replies Last reply Reply Quote 0
                            • Timmerx
                              Timmerx @Hiltex last edited by

                              @Hiltex

                              HI Hiltes es scheint als ob du das mit dem Ebus wirklich verstanden hast und auch anwenden kannst.

                              Ich bin bis jetzt noch nicht dahinter gekommen! Ich finden die Beschreibung im Wiki auch sehr kompliziert.
                              Könntest du vielleicht mir (und auch für andere) ein Beispiel vielleicht auch Bebilder zeigen, wie du manuell Werte abfragst und wo man was eintragen muss?

                              1 Reply Last reply Reply Quote 0
                              • Rene_HM
                                Rene_HM Developer @Hiltex last edited by

                                @Hiltex sagte in Adapter: ebus:

                                Die Werte unter Broadcast werden ohne Abfrage einfach von der Theme/WP an alle Busteilnehmer gesendet und entsprechend auch in ioBroker angezeigt. Meines Wissens nach kann man dieses Verhalten nicht beeinflussen.

                                genau so funktioniert ebusd und damit auch der Adapter: er lauscht, was am Bus vorbei kommt und schreibt sich das auf.
                                Man kann aber selbst Abfragen auf den Bus legen. Dazu muss man nur die gewünschen (und natürlich im System bekannten) Datenpunkte in diese Liste ("Komma-getrennte Liste von abgefragten Datenpunkte") eintragen.
                                bild1.PNG

                                Der Adapter legt dann bei jedem Aufruf ein read-Kommando auf jeden dieser Datenpunkte auf den Bus.

                                MassiveAttack J 2 Replies Last reply Reply Quote 0
                                • MassiveAttack
                                  MassiveAttack @Rene_HM last edited by

                                  @Rene_HM
                                  und wenn ich das mache, bekomme ich immer ein telnet timeout, obwohl ein http aufruf mir diese DP anzeigt.
                                  warum passiert das? wie kann ich das ändern?

                                  M 1 Reply Last reply Reply Quote 0
                                  • M
                                    mameier1234 @MassiveAttack last edited by

                                    @MassiveAttack sagte in Adapter: ebus:

                                    @Rene_HM
                                    und wenn ich das mache, bekomme ich immer ein telnet timeout, obwohl ein http aufruf mir diese DP anzeigt.
                                    warum passiert das? wie kann ich das ändern?

                                    Ich hatte dich jetzt schon mehrfach gefragt, ob du dich mit telnet <ip> 8888 von hand auf den ebusd verbinden kannst...
                                    Also nicht ebusctl auf der console sondern von einer anderen Maschine auf den ebusd per telnet verbinden... Wenn das nicht klappt, dann kann der Adapter sich auch nicht verbinden..

                                    Wenn das klappt, dann im Telnet mal mit info, find, read usw... arbeiten, ob das Daten kommen.

                                    MassiveAttack 1 Reply Last reply Reply Quote 0
                                    • MassiveAttack
                                      MassiveAttack @mameier1234 last edited by

                                      @mameier1234
                                      hab doch schon geschrieben dass das mit telnet von einem anderen host auch in ein timeout läuft. die frage ist warum, und was kann ich tun damit das funktioniert?

                                      M 1 Reply Last reply Reply Quote 0
                                      • M
                                        mameier1234 @MassiveAttack last edited by

                                        @MassiveAttack dann hat das gar nix mit dem adapter zu tun...

                                        sondern eher damit, dass der telnet-daemon auf dem Raspi, auf dem der ebusd läuft nicht installiert ist..

                                        MassiveAttack 1 Reply Last reply Reply Quote 0
                                        • MassiveAttack
                                          MassiveAttack @mameier1234 last edited by

                                          @mameier1234
                                          ok, danke. dann muss ich das telnet noch installieren und starten

                                          ich habe meine ganze infrastruktur neu aufgesetzt, ein echtes debian image (anstelle des ebusd docker image), ebusd dann manuell installiert. jedoch kann er hier keine configs downloaden, er findet beim scan zwar die vaillant, jedoch wird kein file gezogen.
                                          ich habe dann alle config manuell aus (ebusd-configuration-2.1.1) manuell nach /etc/ebusd/ kopiert. darin befinden sich _templates.csv, broadcast.csv, memory.csv und der ordner vaillant mit allen vaillant csvs.
                                          ich hab dann den pfad geändert auf "configpath=/etc/ebusd/" ==> ist das korrekt?

                                          M 1 Reply Last reply Reply Quote 0
                                          • M
                                            mameier1234 @MassiveAttack last edited by

                                            @MassiveAttack ich würde mal sagen: ja...

                                            Telnetserver ist wie gesagt natürlich vorraussetzung, dass du per Telnet auf die Kiste zugreifen kannst...

                                            Deshalb gibt es ja auch den Parameter TelnetPort (8888)

                                            MassiveAttack 3 Replies Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate
                                            FAQ Cloud / IOT
                                            HowTo: Node.js-Update
                                            HowTo: Backup/Restore
                                            Downloads
                                            BLOG

                                            634
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            ebus adapter
                                            68
                                            677
                                            148596
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo