    This topic has been deleted. Only users with topic management privileges can see it.
    • P
      pix last edited by

      @pustekuchen:

      EDIT: Wenn ich beim Schaltaktor den Datenpunkt LEVEL mit "0" füttere kommt im Log folgendes: "warn Wrong type of data input. Please try again" `
      Bist du sicher?

      Der Code zur Überprüfung des input ist ja so:

      ! ````
      if (controller == 'level') { // control via level e.g. RolloTronStandar.level
      // check if input number is between 0 an 100
      if (input.search(/(?:\b|-)([1-9]{1,2}[0]?|100)\b/gmi) != -1) { // 0 to 100 https://regex101.com/r/mN1iT5/6#javascript
      valid = true;
      url = 'http://' + ip + '/deviceajax.do?cid=9&did=' + deviceid + '&goto=' + input + '&command=1';
      } else valid = false;
      } else if (controller == 'level_inverted') { // control via inverted level e.g. RolloTronStandar.level (like Homematic 100% up, 0% down)
      // check if input number is between 0 an 100
      if (input.search(/(?:\b|-)([1-9]{1,2}[0]?|100)\b/gmi) != -1) { // 0 to 100 https://regex101.com/r/mN1iT5/6#javascript
      valid = true;
      url = 'http://' + ip + '/deviceajax.do?cid=9&did=' + deviceid + '&goto=' + (100 - parseInt(input,10)) + '&command=1';
      } else valid = false;
      } else if (controller == 'state') { // control via state e.g. Universal-Aktor switch (100 ist true, <100 is false);
      if (input.search(/(true)|(false)\b/gmi) != -1) { // check if "true" or "false"
      valid = true;
      if (input || input === 'true') { // switch is on
      url = 'http://' + ip + '/deviceajax.do?cid=9&did=' + deviceid + '&goto=100&command=1';
      } else url = 'http://' + ip + '/deviceajax.do?cid=9&did=' + deviceid + '&goto=0&command=1'; // switch is off
      adapter.log.debug('Input: ' + input + ' URL: ' + url);
      } else valid = false;
      }

      
      Also 0 ist eindeutig erlaubt. Sicher, dass du auf dem richtigen Datenpunkt bist?
      
      Wenn du das o.g. Widget nutzt, kannst du bei Min ja 0 und Max ja 100 eingeben und als OID LEVEL. Dann braucht dar Adapter ja nicht umrechnen.
      
      Sonst geht vielleicht mal dieses Widget, auch wenn es nicht so schön ist ;) (OID state)
      

      [{"tpl":"tplFancyToggleswitch","data":{"oid":"nothing_selected","visibility-cond":"==","visibility-val":1,"text_true":"true","text_false":"false","width":"40","signals-cond-0":"==","signals-val-0":true,"signals-icon-0":"/vis/signals/lowbattery.png","signals-icon-size-0":0,"signals-blink-0":false,"signals-horz-0":0,"signals-vert-0":0,"signals-hide-edit-0":false,"signals-cond-1":"==","signals-val-1":true,"signals-icon-1":"/vis/signals/lowbattery.png","signals-icon-size-1":0,"signals-blink-1":false,"signals-horz-1":0,"signals-vert-1":0,"signals-hide-edit-1":false,"signals-cond-2":"==","signals-val-2":true,"signals-icon-2":"/vis/signals/lowbattery.png","signals-icon-size-2":0,"signals-blink-2":false,"signals-horz-2":0,"signals-vert-2":0,"signals-hide-edit-2":false,"highlight_switch":false,"test":false},"style":{"left":"436px","top":"492px"},"widgetSet":"fancyswitch"}]

      
      Gruß
      
      Pix
      1 Reply Last reply Reply Quote 0
      • P
        pustekuchen last edited by

        @pix:

        Kannst du mir mal die JSON schicken, wenn der Aktor ausgeschaltet ist?

        Pix `

        {  "response": "get_visible_devices",  "status": "ok",  "devices": [    {      "did": 10009,      "name": "Gartenbeleuchtung",      "description": " ",      "initialized": 1,      "position": 0,      "productName": "Universal-Aktor",      "serial": "43",      "statusesMap": {        "Position": 0,        "Manuellbetrieb": 0      },      "status_changed": 1466276021,      "deviceGroup": 1,      "iconSet": {        "name": "Ein-Aus-Schalter",        "description": "Ein- Aus-Schalter Icon-Set",        "strMin": "An",        "strMax": "Aus",        "valMax": 100,        "valMin": 0,        "sprite": {          "imageUri": "images/sets/ein-aus-schalter1.png",          "numTiles": 2        },        "k": "iconset5"      },      "iconSetInverted": 0,      "paired": 0,      "statusValid": true,      "uid": "43 XX XX",      "visible": true,      "groups": [        5003      ],      "favoredId": 5013,      "properties": {        "generic": 3,        "wind": 3,        "trigger": 3,        "closingContact": 3,        "dusk": 3,        "smoke": 3,        "sun": 3,        "temperature": 3,        "manual": 3,        "time": 2,        "dawn": 3,        "dust": 3,        "favored": 0,        "smartphone": 3,        "motion": 3,        "temperator": 3,        "warning": 3,        "rain": 3,        "states": [          {            "cfgKey": "setAutomationOverall",            "cfgId": 99,            "state": 0          },          {            "cfgKey": "setSunAuto",            "cfgId": 105,            "state": 0          },          {            "cfgKey": "setEveningAuto",            "cfgId": 107,            "state": 1          },          {            "cfgKey": "setTimeAuto",            "cfgId": 101,            "state": 1          },          {            "cfgKey": "setMorningAuto",            "cfgId": 103,            "state": 1          }        ]      },      "sortId": 718,      "sTypes": [],      "version": "2.2",      "sync": -2147480277,      "messages": [],      "hasErrors": 0,      "autos": [        3,        2,        0,        1,        4      ]    },   
        
        1 Reply Last reply Reply Quote 0
        • P
          pustekuchen last edited by

          @pix:

              } else if (controller == 'state') { // control via state e.g. Universal-Aktor switch (100 ist true, <100 is false);
                  if (input.search(/(true)|(false)\b/gmi) != -1) { // check if "true" or "false"
                      valid = true;
                      if (input || input === 'true') { // switch is on
                          url = 'http://' + ip + '/deviceajax.do?cid=9&did=' + deviceid + '&goto=100&command=1';
                      } else url = 'http://' + ip + '/deviceajax.do?cid=9&did=' + deviceid + '&goto=0&command=1'; // switch is off
                      adapter.log.debug('Input: ' + input + ' URL: '  + url);
                  } else valid = false;
              }
          ```` `  
          

          Habe im Code gesehen, du setzt cid=9 mit Position N auch beim Schaltaktor ein. Für die Schaltaktoren gibt es doch den CID 10 für AN und 11 für AUS. Ist der CID 10 bzw. 11 für den Datenpunkt STATE nicht besser geeignet? Dummerweise gibt das JSON als Rückmeldung trotzdem den Wert als "POSITION" aus.

          Also sieht es dann so aus:

          else if (controller == 'state') { // control via state e.g. Universal-Aktor switch (100 ist true, <100 is false);
                  if (input.search(/(true)|(false)\b/gmi) != -1) { // check if "true" or "false"
                      valid = true;
                      if (input || input === 'true') { // switch is on
                          url = 'http://' + ip + '/deviceajax.do?cid=10&did=' + deviceid + '&command=1';
                      } else url = 'http://' + ip + '/deviceajax.do?cid=11&did=' + deviceid + '&command=1'; // switch is off
                      adapter.log.debug('Input: ' + input + ' URL: '  + url);
                  } else valid = false;
              }
          
          1 Reply Last reply Reply Quote 0
          • P
            pix last edited by

            Du hast recht. Macht ja auch Sinn. Ich war immer noch überzeugt, true sei Position 100, false sei 0; auch beim Setzen. Aber Cid ist ja genau dafür da. Mach ich morgen!

            Muss mir wohl auch mal so einen Aktor zulegen.

            Gute Nacht,

            Pix

            Gesendet mit Tapatalk

            1 Reply Last reply Reply Quote 0
            • P
              pustekuchen last edited by

              @pix:

              Du hast recht. Macht ja auch Sinn. Ich war immer noch überzeugt, true sei Position 100, false sei 0; auch beim Setzen. Aber Cid ist ja genau dafür da. Mach ich morgen!

              Muss mir wohl auch mal so einen Aktor zulegen.

              Gute Nacht,

              Pix

              Gesendet mit Tapatalk `
              Cool. Kannst du evtl. noch die Synctime in den Settings einstellbar machen? Und was noch schick wäre: Eine Fehlermeldung, wenn der Homepilot nicht erreichbar ist, oder ist das schon drin? Ich würde gerne eine "Servicemeldung" à la Homematic einblenden lassen, wenn die Verbindung nicht möglich ist.

              1 Reply Last reply Reply Quote 0
              • L
                leo013 last edited by

                Hallo Pix,

                das Design von deinem widget passt leider nicht zu meiner Visu 😉

                997_iobroker1.jpg

                997_iobroker2.jpg

                Ich glaube das Widget, das ich nutze ist von Bluefox.

                Im Moment kann ich mit der Tastensteuerung leben, die Gurtwickler laufen automatisch über

                die Dämmerungs- und Sonnenaufgangsfunktion, sowie Beschattung bei starken Sonneneinfall.

                Ich habe fast meine komplette Dashui-Visu auf iobroker umgestellt, muss nur noch meine beiden Homeduino einbinden

                Nochmals herzlichen Dank für die schnelle Umsetzung!

                Gruß

                Wolfgang

                1 Reply Last reply Reply Quote 0
                • P
                  pix last edited by

                  Hallo,

                  0.0.5 ist fertig

                  https://github.com/Pix–-/ioBroker.homepilot

                  Neu:

                  • Die Dauer in Sekunden zwischen den Synchronisierungen Homepilot <> ioBroker lässt sich nun einstellen (default 12s).

                  • Switches/Schalter (Serie 43 und 46) werden nun per Commad ID gesetzt, aber noch über Position/Level aus Homepilot gelesen.

                  • Datenpunkt UNREACH erstellt.

                    Wenn Homepilot nicht erreichbar, wird UNREACH auf true gesetzt (zB für Alarmierung). Bitte prüfen, ob das Setzen auf true bei Adapter Installation bis zum ersten einlesen schon die Alarmierung auslöst. Dann muss ich das ändern.

                  • Readme aufgehübscht

                  Gruß

                  Pix

                  1 Reply Last reply Reply Quote 0
                  • M
                    mdsv last edited by

                    Hallo,

                    bei mir geht die Installation leider nicht. Sowohl über die GUI, als auch die Konsole.

                    Müsste es gehen????

                    404 https://registry.npmjs.org/iobroker.homepilot

                    npm ERR! TypeError: Cannot read property 'latest' of undefined

                    npm ERR! at next (/usr/local/lib/node_modules/npm/lib/cache.js:687:35)

                    npm ERR! at /usr/local/lib/node_modules/npm/lib/cache.js:675:5

                    npm ERR! at saved (/usr/local/lib/node_modules/npm/node_modules/npm-registry-client/lib/get.js:142:7)

                    npm ERR! at /usr/local/lib/node_modules/npm/node_modules/graceful-fs/polyfills.js:133:7

                    npm ERR! at Object.oncomplete (fs.js:107:15)

                    npm ERR! If you need help, you may report this log at:

                    npm ERR! <http://github.com/isaacs/npm/issues>

                    npm ERR! or email it to:

                    npm ERR! npm-@googlegroups.com

                    1 Reply Last reply Reply Quote 0
                    • P
                      pustekuchen last edited by

                      @pix:

                      Hallo,

                      0.0.5 ist fertig

                      https://github.com/Pix–-/ioBroker.homepilot

                      Neu:

                      • Die Dauer in Sekunden zwischen den Synchronisierungen Homepilot <> ioBroker lässt sich nun einstellen (default 12s).

                      • Switches/Schalter (Serie 43 und 46) werden nun per Commad ID gesetzt, aber noch über Position/Level aus Homepilot gelesen.

                      • Datenpunkt UNREACH erstellt.

                        Wenn Homepilot nicht erreichbar, wird UNREACH auf true gesetzt (zB für Alarmierung). Bitte prüfen, ob das Setzen auf true bei Adapter Installation bis zum ersten einlesen schon die Alarmierung auslöst. Dann muss ich das ändern.

                      • Readme aufgehübscht

                      Gruß

                      Pix `
                      Neue Version installiert, leider geht das ausschalten der Schaltaktoren über STATE false immer noch nicht. Edit: Einschalten geht, aber ausschalten dann nicht mehr.

                      1 Reply Last reply Reply Quote 0
                      • P
                        pix last edited by

                        Seltsam, hier der Code, der das Schalten übernimmt:

                        else if (controller == 'state') { // control via state e.g. Universal-Aktor switch
                                if (input.search(/(true)|(false)\b/gmi) != -1) { // check if "true" or "false"
                                    valid = true;
                                    newcid = (input || input === 'true') ? '10' : '11'; // hier sollte bei 'false' eigentlich '11' gesetzt werden
                                    if (valid) url = 'http://' + ip + '/deviceajax.do?did=' + deviceid + '&cid=' + newcid + '&command=1'; // switch ON / OFF
                                    adapter.log.debug('Switch ' + deviceid + ' new status detected: ' + input + ' URL: '  + url);
                                } else valid = false;
                            } 
                        

                        Was sagt das Log (hier 6. Zeile, also Adapter bitte auf debug stellen)?

                        Gruß

                        Pix

                        1 Reply Last reply Reply Quote 0
                        • P
                          pustekuchen last edited by

                          Log sagt:

                          ! ````
                          homepilot-0 2016-06-19 15:09:24.490 warn Wrong type of data input. Please try again
                          homepilot-0 2016-06-19 15:09:20.895 warn Wrong type of data input. Please try again
                          homepilot-0 2016-06-19 15:09:19.959 info Command sent to Homepilot because "false" written to State "homepilot.0.devices.Steckdosenaktor.10006.state"
                          homepilot-0 2016-06-19 15:09:13.213 warn Wrong type of data input. Please try again
                          homepilot-0 2016-06-19 15:09:12.220 info Command sent to Homepilot because "true" written to State "homepilot.0.devices.Steckdosenaktor.10006.state"
                          homepilot-0 2016-06-19 15:09:09.915 warn Wrong type of data input. Please try again
                          homepilot-0 2016-06-19 15:08:57.730 warn Wrong type of data input. Please try again

                          Hätte ich jetzt seit dem du geantwortet hast nochmal updaten müssen?
                          1 Reply Last reply Reply Quote 0
                          • P
                            pix last edited by

                            Nein, hätest du nicht. Habe nichts verändert.

                            Du sagst ja, dass das Einschalten funktioniert, nur das Ausschalten nicht.

                            Also true geht, false nicht.

                            Seltsam ist ja, dass durch diese Zeile

                            newcid = (input || input === 'true') ? '10' : '11'; // hier sollte bei 'false' eigentlich '11' gesetzt werden
                            

                            genau nach "true" gefragt wird (sowohl als boolean, als auch als Zeichenkette) und falls kein true kommt, und dazu gehört 'false' ja, dann soll die 11 gesetzt werden (für AUS).

                            Mir fehlt nur diese Zeile in der Logausgabe:

                            adapter.log.debug('Switch ' + deviceid + ' new status detected: ' + input + ' URL: '  + url);
                            

                            Deshalb bitte mal den Adapter auf DEBUG stellen (Reiter Instanzen, Expertenmodus. Logstufe) 261_bildschirmfoto_2016-06-19_um_22.03.12.jpg

                            Gruß

                            Pix

                            1 Reply Last reply Reply Quote 0
                            • P
                              pustekuchen last edited by

                              Ok, hier die Debug-Ausgabe nachdem ich ausgeschaltet habe:

                              homepilot.0 Wrong type of data input. Please try again
                              homepilot.0	2016-06-19 22:25:51.217	debug	homepilot.0 State: state device: 10006 command: 0
                              homepilot.0	2016-06-19 22:25:51.216	debug	homepilot.0 input value: 0
                              homepilot.0	2016-06-19 22:25:51.216	debug	homepilot.0 stateChange homepilot.0.devices.Steckdosenaktor.10006.state {"val":"0","ack":false,"ts":1466367951198,"q":0,"from":"system.adapter.web.0","lc":1466367951198}
                              homepilot.0	2016-06-19 22:25:51.214	debug	inMem message homepilot.0.* homepilot.0.devices.Steckdosenaktor.10006.state
                              homepilot.0	2016-06-19 22:25:50.318	info	homepilot.0 Command sent to Homepilot because "false" written to State "homepilot.0.devices.Steckdosenaktor.10006.state"
                              homepilot.0	2016-06-19 22:25:50.318	debug	homepilot.0 Switch 10006 new status detected: false URL: http://192.168.178.5/deviceajax.do?did=10006&cid=10&command=1
                              homepilot.0	2016-06-19 22:25:50.317	debug	homepilot.0 State: state device: 10006 command: false
                              homepilot.0	2016-06-19 22:25:50.317	debug	homepilot.0 input value: false
                              homepilot.0	2016-06-19 22:25:50.317	debug	homepilot.0 stateChange homepilot.0.devices.Steckdosenaktor.10006.state {"val":false,"ack":false,"ts":1466367950226,"q":0,"from":"system.adapter.web.0","lc":1466367950226}
                              homepilot.0	2016-06-19 22:25:50.315	debug	inMem message homepilot.0.* homepilot.0.devices.Steckdosenaktor.10006.state
                              homepilot.0	2016-06-19 22:25:46.005	debug	homepilot.0 Homepilot adapter started...
                              homepilot.0	2016-06-19 22:25:46.005	debug	homepilot.0 Homepilot station and ioBroker synchronize every 12s
                              homepilot.0	2016-06-19 22:25:46.004	debug	homepilot.0 initializing objects
                              
                              

                              Edit: Ok, jetzt habe ich herausgefunden, dass der CID falsch ist, bei STATE false wird 10, also Einschalten benutzt anstatt 11.

                              Gesendet von meinem iPad mit Tapatalk HD

                              1 Reply Last reply Reply Quote 0
                              • P
                                pix last edited by

                                Vielen Dank für die Rückmeldung. Jetzt habe ich den Fehler wohl gefunden:

                                newcid = (input || input === 'true') ? '10' : '11';
                                

                                Input ist ja kein Typ boolean, sondern ein Typ String. Deshalb wird die obige Abfrage immer '10' ergeben, da auch der übergebene String 'false' eben ein String ist und die Variable füllt. Es wird ja nur gerpüft, ob was drin steht, erst nach dem ODER wird geprüft, obt das auch "true" ist.

                                Da ich oben weiter eh schon die Regex-Abfrage für plausible Eingaben habe, konnte ich die natürlich weiter unten auch nutzen.

                                if (input.search(/(true)(EIN)(AN)(ON)|([10-11])|(false)(AUS)(OFF)\b\b/gmi) != -1) { // check if "true" or "false"
                                            valid = true;
                                            if (input.search(/(true)(EIN)(AN)(ON)|(10)\b\b/gmi) != -1 ) newcid = '10'; 
                                            if (input.search(/(false)(AUS)(OFF)|(11)\b\b/gmi) != -1 ) newcid = '11'; 
                                            url = 'http://' + ip + '/deviceajax.do?did=' + deviceid + '&cid=' + newcid + '&command=1'; // switch ON / OFF
                                            adapter.log.debug('Switch ' + deviceid + ' new status detected: ' + input + ' URL: '  + url);
                                        } else valid = false;
                                
                                

                                Es sind jetzt eben auch die in der https://github.com/Pix–-/ioBroker.homepilot/blob/master/README.md#command-id aufgezählten CID Anweisungen möglich (zB "AUS" oder "off" oder "EiN", wenn es sein muss 🙂 )

                                Neue Version 0.0.6 mit Korrektur ist da.

                                https://github.com/Pix–-/ioBroker.homepilot

                                Gruß

                                Pix

                                1 Reply Last reply Reply Quote 0
                                • P
                                  pustekuchen last edited by

                                  Nach Update kann ich jetzt nur noch an- der ausschalten, wenn ich "10" oder "11" in STATE schreibe. "true" oder "false" oder "AN" oder "AUS", gehen nicht.

                                  Geht nicht:

                                  ! ````
                                  homepilot.0 2016-06-20 15:11:40.520 debug homepilot.0 finished reading Homepilot Data
                                  homepilot.0 2016-06-20 15:11:40.518 debug homepilot.0 reading homepilot JSON ...
                                  TypeError: 2016-06-20 13:11:36.854 error at Manager.ondecoded (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/manager.js:333:8)
                                  TypeError: 2016-06-20 13:11:36.854 error at Manager.Emitter.emit (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/node_modules/component-emitter/index.js:131:20)
                                  TypeError: 2016-06-20 13:11:36.854 error at Manager. (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/node_modules/component-bind/index.js:21:15)
                                  TypeError: 2016-06-20 13:11:36.854 error at Socket.onpacket (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/socket.js:221:12)
                                  TypeError: 2016-06-20 13:11:36.854 error at Socket.onevent (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/socket.js:263:10)
                                  TypeError: 2016-06-20 13:11:36.854 error at Socket.Emitter.emit (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/node_modules/component-emitter/index.js:131:20)
                                  TypeError: 2016-06-20 13:11:36.854 error at Socket. (/opt/iobroker/node_modules/iobroker.js-controller/lib/states/statesInMemClient.js:45:30)
                                  TypeError: 2016-06-20 13:11:36.854 error at Object.that.states.States.change (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:2036:80)
                                  TypeError: 2016-06-20 13:11:36.854 error at Object.utils.adapter.stateChange (/opt/iobroker/node_modules/iobroker.homepilot/main.js:22:9)
                                  TypeError: 2016-06-20 13:11:36.854 error at controlHomepilot (/opt/iobroker/node_modules/iobroker.homepilot/main.js:166:23)
                                  TypeError: 2016-06-20 13:11:36.854 error Cannot read property 'warn' of undefined
                                  message 2016-06-20 13:11:36.836 error homepilot.0.devices.Steckdosenaktor.10006.state [object Object] Cannot read property 'warn' of undefined
                                  homepilot-0 2016-06-20 13:11:36.832 debug State: state device: 10006 command: true
                                  homepilot-0 2016-06-20 13:11:36.828 debug input value: true
                                  homepilot-0 2016-06-20 13:11:36.826 debug stateChange homepilot.0.devices.Steckdosenaktor.10006.state {"val":true,"ack":false,"ts":1466428296807,"q":0,"from":"system.adapter.admin.0","lc":1466428296807}
                                  inMem 2016-06-20 13:11:36.816 debug message homepilot.0.* homepilot.0.devices.Steckdosenaktor.10006.state val=true, ack=false, ts=1466428296807, q=0, from=system.adapter.admin.0, lc=1466428296807
                                  homepilot-0 2016-06-20 13:11:28.451 debug Homepilot adapter started...
                                  homepilot-0 2016-06-20 13:11:28.450 debug Homepilot station and ioBroker synchronize every 12s
                                  homepilot-0 2016-06-20 13:11:28.446 debug initializing objects
                                  homepilot-0 2016-06-20 13:11:28.431 info starting. Version 0.0.6 in /opt/iobroker/node_modules/iobroker.homepilot
                                  homepilot-0 2016-06-20 13:11:28.208 debug statesDB connected
                                  homepilot-0 2016-06-20 13:11:28.158 debug objectDB connected

                                  
                                  Geht schon: (mit "10")
                                  
                                  >! ````
                                  homepilot.0	2016-06-20 15:14:04.759	debug	homepilot.0 reading homepilot JSON ...
                                  homepilot-0	2016-06-20 13:14:01.388	info	Command sent to Homepilot because "10" written to State "homepilot.0.devices.Steckdosenaktor.10006.state"
                                  homepilot-0	2016-06-20 13:14:01.377	debug	Switch 10006 new status detected: 10 URL: http://192.168.178.5/deviceajax.do?did=10006&cid=10&command=1
                                  homepilot-0	2016-06-20 13:14:01.374	debug	State: state device: 10006 command: 10
                                  homepilot-0	2016-06-20 13:14:01.374	debug	input value: 10
                                  homepilot-0	2016-06-20 13:14:01.373	debug	stateChange homepilot.0.devices.Steckdosenaktor.10006.state {"val":10,"ack":false,"ts":1466428441359,"q":0,"from":"system.adapter.admin.0","lc":1466428441359}
                                  inMem	2016-06-20 13:14:01.370	debug	message homepilot.0.* homepilot.0.devices.Steckdosenaktor.10006.state val=10, ack=false, ts=1466428441359, q=0, from=system.adapter.admin.0, lc=1466428441359
                                  
                                  1 Reply Last reply Reply Quote 0
                                  • P
                                    pix last edited by

                                    Danke für die Rückmeldung. Tut mir leid, waren Flüchtigkeitsfehler. Hab schon einen Schreibfehler gefunden: "adapter.lo.warn"

                                    Ausserdem fehlte in der RegEx Abfrage wohl einige ODER :oops:

                                    Ich lade mal schnell eine neue Version hoch 0.0.7. 8-)

                                    Gruß

                                    Pix

                                    1 Reply Last reply Reply Quote 0
                                    • P
                                      pustekuchen last edited by

                                      @pix:

                                      Danke für die Rückmeldung. Tut mir leid, waren Flüchtigkeitsfehler. Hab schon einen Schreibfehler gefunden: "adapter.lo.warn"

                                      Ausserdem fehlte in der RegEx Abfrage wohl einige ODER :oops:

                                      Ich lade mal schnell eine neue Version hoch 0.0.7. 8-)

                                      Gruß

                                      Pix `
                                      Danke, jetzt läufts! 😉

                                      1 Reply Last reply Reply Quote 0
                                      • P
                                        pustekuchen last edited by

                                        Ich wollte nochmal auf die Einstellungsmöglichkeit des Manuellbetriebs der Aktoren/Rollotrons zurückkommen.

                                        Wäre es möglich einen Datenpunkt "OVERALL_AUTOMATION" mit Typ boolean (true/false) für jedes Gerät einzuführen?

                                        Das Setzen der Automation bzw. des Manuellbetriebs geschieht mittels folgender Anfrage:````
                                        http://homepilot/deviceajax.do?automation=1&data={"did":10005,"automation":3,"state":false}

                                        Dabei ist "automation:3" die Funktion, um den Manuellmodus zu aktivieren "state:true" bzw. zu deaktiveren "state:false".
                                        
                                        Ausgelesen werden kann der Status des Geräts mittels````
                                        "statusesMap":{"Position":100,"Manuellbetrieb":0}
                                        ````innerhalb der Standardabfrage von````
                                        http://homepilot/deviceajax.do?devices=1
                                        ````, also "Manuellbetrieb":0 für deaktiviert bzw. "Manuellbetrieb":1 für aktivert.
                                        
                                        Wäre vielleicht für den ein oder anderen eine sinnvolle Ergänzung! :idea:
                                        
                                        EDIT:
                                        
                                        Habe gerade eine weitere sinnvolle Ergänzung gefunden, eine Rückmeldung, ob der Aktor erreichbar ist und sich zurückmeldet. Diese Info verbirgt sich hinter der Rückmeldung auf die Abfrage mit````
                                        http://homepilot/deviceajax.do?devices=1
                                        ````bei````
                                        "statusValid":false,
                                        ````, "true", wenn der Befehl angekommen ist und das Gerät sich zurückmeldet und "false", wenn nicht. Habe es eben ausprobiert mit einer Schaltsteckdose. Gilt aber m.E. für alle Geräte.
                                        
                                        Damit könnte man noch einen "UNREACH"-Datenpunkt einführen.
                                        1 Reply Last reply Reply Quote 0
                                        • P
                                          pix last edited by

                                          Hallo pustekuchen,

                                          die nächsten Tage wird das erstmal nix. Habe da beruflich viel zu tun.

                                          Vielleicht danach. Wozu ist denn der manuelle Modus?

                                          Gruß

                                          Pix

                                          1 Reply Last reply Reply Quote 0
                                          • P
                                            pustekuchen last edited by

                                            Beispiel: Terrasse. Ich benutze den FDK bzw TFK der Homematic für den Fensterstatus. Ist an der Terrasse die Türe offen oder gekippt, dann geht der Rollo auf manuell und fährt abends nicht herunter, damit man sich nicht aussperrt, wenn man noch draußen sitzt. Sobald die Türe geschlossen wird, geht der Rollo wieder auf Automatik.

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate
                                            FAQ Cloud / IOT
                                            HowTo: Node.js-Update
                                            HowTo: Backup/Restore
                                            Downloads
                                            BLOG

                                            810
                                            Online

                                            31.9k
                                            Users

                                            80.3k
                                            Topics

                                            1.3m
                                            Posts

                                            21
                                            125
                                            18526
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo