    Ошибка создания объекта в OWFS

    This topic has been deleted. Only users with topic management privileges can see it.
    • A
      Alekseym6 last edited by

      iobroker object get owfs.0.wires.SensorTemp --pretty
      {
        "type": "state",
        "common": {
          "name": "SensorTemp",
          "def": false,
          "type": "number",
          "read": "true",
          "write": "true",
          "role": "value.temperature10",
          "desc": "1wire sensor",
          "history": {
            "sql.0": {
              "enabled": true,
              "changesOnly": true,
              "debounce": 1000,
              "retention": 0
            },
            "sql.1": {
              "enabled": true,
              "changesOnly": true,
              "debounce": 1000,
              "retention": 0
            },
            "history.0": {
              "enabled": true,
              "changesOnly": true,
              "debounce": 1000,
              "maxLength": 500,
              "retention": 0
            }
          }
        },
        "native": {
          "id": "28.7F821C060000",
          "property": "temperature10"
        },
        "_id": "owfs.0.wires.SensorTemp"
      }
      
      1 Reply Last reply Reply Quote 0
      • A
        Alekseym6 last edited by

        @Bluefox:

        Какие ещё могут полезные свойства?

            var possibleProperties = [
                'humidity',
                'temperature',
                'fasttemp',
                'date',
                'PIO',
                'PIO.A',
                'PIO.B',
                'PIO.0',
                'PIO.1',
                'PIO.2',
                'PIO.3',
                'PIO.4',
                'PIO.5',
                'PIO.6',
                'PIO.7',
                'PIO.ALL',
                'PIO.BYTE',
                'latch.0',
                'latch.1',
                'latch.2',
                'latch.3',
                'latch.4',
                'latch.5',
                'latch.6',
                'latch.7',
                'latch.ALL',
                'latch.BYTE'
            ];
        ```` `  
        

        sensed.BYTE

        PIO.BYTE

        получить или установить сразу 2 порта IO

        1 Reply Last reply Reply Quote 0
        • Bluefox
          Bluefox last edited by

          @Alekseym6:

          iobroker object get owfs.0.wires.SensorTemp --pretty
          {
            "type": "state",
            "common": {
              "name": "SensorTemp",
              "def": false,
              "type": "number",
              "read": "true",
              "write": "true",
              "role": "value.temperature10",
              "desc": "1wire sensor",
              "history": {
                "sql.0": {
                  "enabled": true,
                  "changesOnly": true,
                  "debounce": 1000,
                  "retention": 0
                },
                "sql.1": {
                  "enabled": true,
                  "changesOnly": true,
                  "debounce": 1000,
                  "retention": 0
                },
                "history.0": {
                  "enabled": true,
                  "changesOnly": true,
                  "debounce": 1000,
                  "maxLength": 500,
                  "retention": 0
                }
              }
            },
            "native": {
              "id": "28.7F821C060000",
              "property": "temperature10"
            },
            "_id": "owfs.0.wires.SensorTemp"
          }
          ```` `  
          

          Поменяй

          "def": false,

          на

          "def": 0,

          и ошибка должна исчезнуть

          1 Reply Last reply Reply Quote 0
          • Bluefox
            Bluefox last edited by

            @Haus:

            Главное посмотри почему с удалённого неработает `
            Поменяй в файле /etc/owfs.conf

            # With this setup, any client (but owserver) uses owserver on the
            # local machine...
            !server: -s 4304
            
            

            и

            ####################### OWSERVER ########################
            
            server: -p 4304
            
            

            У тебя только локальный доступ настроен

            1 Reply Last reply Reply Quote 0
            • Bluefox
              Bluefox last edited by

              @Haus:

              @Bluefox:

              Объясни, зачем тебе другие атрибуты? Что бы цикл чтения тормозить? `
              Мне не надо это я для проверки. Для DS18B20 DS18S20 temperature и DS2413 PIO.A, PIO.B , вот DS2406 там ещё что то нужно но не использовал незнаю.

              Главное посмотри почему с удалённого неработает

              P.S Вот нашел DS2406 и DS2408 могут

              "Вместо DS2405 был использован двухканальный компонент DS2406P, где один канал отвечал за включение-выключение процесса аэрации, а второй канал использовался как датчик сухого контакта и определял моменты включения насоса (эмулируя нажатие кнопки). Эта схема работала, но как обрабатывать срабатывание насоса программно? Оказывается, весьма несложно. Для этих целей лучше всего использовать свойство компонента set_alarm, установив его значение '230'. Такая установка означает, что в случае срабатывания датчика на канале B, сервер owfs сообщит об этом создав линк на файл устройства в каталоге alarm" `
              set_alarm сложный объект:

              ├── set_alarm
              │   │   ├── dew_point_hi
              │   │   ├── dew_point_low
              │   │   ├── heat_index_hi
              │   │   ├── heat_index_low
              │   │   ├── humidex_hi
              │   │   ├── humidex_low
              │   │   ├── humidity_hi
              │   │   ├── humidity_low
              │   │   ├── temp_hi
              │   │   └── temp_low
              
              1 Reply Last reply Reply Quote 0
              • Bluefox
                Bluefox last edited by

                @Alekseym6:

                @Bluefox:

                Какие ещё могут полезные свойства? `

                sensed.BYTE

                PIO.BYTE

                получить или установить сразу 2 порта IO `
                я расширил:

                var possibleProperties = [
                        'humidity',
                        'pressure',
                        'inHg',
                        'vib_level',
                        'vib_peak',
                        'vib_min',
                        'vib_max',
                        'current.0',
                        'current.1',
                        'current.2',
                        'current.ALL',
                        'min_current.0',
                        'min_current.1',
                        'min_current.2',
                        'min_current.ALL',
                        'max_current.0',
                        'max_current.1',
                        'max_current.2',
                        'max_current.ALL',
                        'volts.0',
                        'volts.1',
                        'volts.2',
                        'volts.ALL',
                        'min_volts.0',
                        'min_volts.1',
                        'min_volts.2',
                        'min_volts.ALL',
                        'max_volts.0',
                        'max_volts.1',
                        'max_volts.2',
                        'max_volts.ALL',
                        'gain',
                        'offset',
                        'current',
                        'illuminance',
                        'relay/state',
                        'relay/control',
                        'LED/state',
                        'LED/control',
                        'resistance',
                        'dew_point',
                        'heat_index',
                        'humidex',
                        'light',
                        'temperature',
                        'fasttemp',
                        'set_alarm',
                        'date',
                        'PIO',
                        'PIO.A',
                        'PIO.B',
                        'PIO.0',
                        'PIO.1',
                        'PIO.2',
                        'PIO.3',
                        'PIO.4',
                        'PIO.5',
                        'PIO.6',
                        'PIO.7',
                        'PIO.ALL',
                        'PIO.BYTE',
                        'latch.0',
                        'latch.1',
                        'latch.2',
                        'latch.3',
                        'latch.4',
                        'latch.5',
                        'latch.6',
                        'latch.7',
                        'latch.ALL',
                        'latch.BYTE',
                        'sensed.BYTE'
                    ];
                
                1 Reply Last reply Reply Quote 0
                • H
                  Haus last edited by

                  @Bluefox:

                  @Haus:

                  Главное посмотри почему с удалённого неработает `
                  Поменяй в файле /etc/owfs.conf

                  # With this setup, any client (but owserver) uses owserver on the
                  # local machine...
                  !server: -s 4304
                  
                  

                  и

                  ####################### OWSERVER ########################
                  
                  server: -p 4304
                  
                  

                  У тебя только локальный доступ настроен `

                  Это я уже давно сделал, проблема в чём то другом. Когда я руками заполняю датчики всё работает, а Read addresses "Найдено 0 сенсор(a/ов)"

                  ioBroker server 192.168.1.11

                  owfs server 192.168.1.10 (где подключён адаптер) owfs.conf

                  ! # Sample configuration file for the OWFS suite for Debian GNU/Linux.
                  ! #
                  ! #
                  ! # This is the main OWFS configuration file. You should read the
                  ! # owfs.conf(5) manual page in order to understand the options listed
                  ! # here.
                  ! ######################## SOURCES ########################
                  ! #
                  ! # With this setup, any client (but owserver) uses owserver on the
                  ! # local machine…
                  ! ! server: server = 4304
                  ! #
                  ! # ...and owserver uses the real hardware, by default fake devices
                  ! # This part must be changed on real installation
                  ! #server: FAKE = DS18S20,DS2405
                  ! #
                  ! # USB device: DS9490
                  ! #server: usb = all
                  ! #
                  ! # Serial port: DS9097
                  ! server: passive = /dev/ttyUSB0
                  ! server: 8bit
                  ! #server: passive = /dev/ttyUSB1
                  ! #server: 8bit
                  ! #
                  ! # owserver tcp address
                  ! #server: server = 192.168.10.1:3131
                  ! #
                  ! # random simulated device
                  ! #server: FAKE = DS18S20,DS2405
                  ! #
                  ! ######################### OWFS ##########################
                  ! #
                  ! mountpoint = /mnt/1wire
                  ! allow_other
                  ! #
                  ! ####################### OWHTTPD #########################
                  ! http: port = 2121
                  ! ####################### OWFTPD ##########################
                  ! ftp: port = 2120
                  ! ####################### OWSERVER ########################
                  ! server: port = 4304

                  1 Reply Last reply Reply Quote 0
                  • H
                    Haus last edited by

                    @Bluefox:

                    @Haus:
                    owfs 0.2.1

                    Зачем при read датчик выдаёт fasttemp?

                    Я уже выкладывал log Response for write /Sensor2_temperature/temperature: true ????

                    ! inMem 2016-07-29 13:33:19.406 debug message owfs.1.* owfs.1.wires.Sensor2_temperature val=24.5, ack=true, ts=1469788399389, q=0, from=system.adapter.owfs.1, lc=1469788399389
                    ! owfs-1 2016-07-29 13:33:19.383 debug Read /28.FFF67D3B0400/temperature:24.5
                    ! inMem 2016-07-29 13:33:18.575 debug message owfs.1.* owfs.1.wires.Sensor1_fasttemp val=24.5, ack=true, ts=1469788398559, q=0, from=system.adapter.owfs.1, lc=1469788398559
                    ! owfs-1 2016-07-29 13:33:18.551 debug Read /28.FFF67D3B0400/fasttemp:24.5
                    ! inMem 2016-07-29 13:32:49.589 debug message owfs.1.* owfs.1.wires.Sensor2_temperature val=0, ack=true, ts=1469788369575, q=0, from=system.adapter.owfs.1, lc=1469788369575
                    ! owfs-1 2016-07-29 13:32:49.566 debug Response for write /Sensor2_temperature/temperature: true
                    ! inMem 2016-07-29 13:32:49.507 debug message owfs.1.* owfs.1.wires.Sensor1_fasttemp val=0, ack=true, ts=1469788369492, q=0, from=system.adapter.owfs.1, lc=1469788369492
                    ! owfs-1 2016-07-29 13:32:49.487 debug Response for write /Sensor1_fasttemp/fasttemp: true
                    ! inMem 2016-07-29 13:32:49.479 debug message owfs.1.* owfs.1.wires.Sensor2_temperature val=24.5, ack=true, ts=1469788369458, q=0, from=system.adapter.owfs.1, lc=1469788369458
                    ! owfs-1 2016-07-29 13:32:49.387 debug Read /28.FFF67D3B0400/temperature:24.5
                    ! inMem 2016-07-29 13:32:48.612 debug message owfs.1.* owfs.1.wires.Sensor1_fasttemp val=24.5, ack=true, ts=1469788368599, q=0, from=system.adapter.owfs.1, lc=1469788368599
                    ! owfs-1 2016-07-29 13:32:48.589 debug Read /28.FFF67D3B0400/fasttemp:24.5
                    ! owfs-1 2016-07-29 13:32:48.509 debug Write /28.FFF67D3B0400/temperature with "0"
                    ! owfs-1 2016-07-29 13:32:48.466 debug Write /28.FFF67D3B0400/fasttemp with "0"
                    ! inMem 2016-07-29 13:32:48.450 debug message owfs.1.* owfs.1.wires.Sensor2_temperature val=0, ack=null, ts=1469788368431, q=0, from=system.adapter.owfs.1, lc=1469788368431
                    ! inMem 2016-07-29 13:32:48.407 debug message owfs.1.* owfs.1.wires.Sensor1_fasttemp val=0, ack=null, ts=1469788368378, q=0, from=system.adapter.owfs.1, lc=1469788368378
                    ! owfs-1 2016-07-29 13:32:48.231 info starting. Version 0.2.1 in /opt/iobroker/node_modules/iobroker.owfs
                    ! owfs-1 2016-07-29 13:32:48.139 debug statesDB connected
                    ! owfs-1 2016-07-29 13:32:48.120 debug objectDB connected
                    ! host-Server1 2016-07-29 13:32:46.864 info instance system.adapter.owfs.1 started with pid 3576
                    ! host-Server1 2016-07-29 13:32:44.896 info instance system.adapter.owfs.1 terminated with code 0 (OK)
                    ! owfs-1 2016-07-29 13:32:44.873 info terminating

                    1 Reply Last reply Reply Quote 0
                    • Bluefox
                      Bluefox last edited by

                      > Зачем при read датчик выдаёт fasttemp?
                      Потому что ты сказал в настройках это читать.

                      Есть новая версия на гит

                      1 Reply Last reply Reply Quote 0
                      • H
                        Haus last edited by

                        @Bluefox:

                        > Зачем при read датчик выдаёт fasttemp?
                        Потому что ты сказал в настройках это читать.

                        Есть новая версия на гит `
                        Где я такое говорил?

                        1 Reply Last reply Reply Quote 0
                        • Bluefox
                          Bluefox last edited by

                          @Haus:

                          @Bluefox:

                          > Зачем при read датчик выдаёт fasttemp?
                          Потому что ты сказал в настройках это читать.

                          Есть новая версия на гит Где я такое говорил?
                          😄

                          в настройках

                          Ты настроил драйвер так, что бы он читал эту переменную. Удали её из конфига.

                          1 Reply Last reply Reply Quote 0
                          • H
                            Haus last edited by

                            @Bluefox:

                            @Haus:

                            @Bluefox:

                            Потому что ты сказал в настройках это читать.

                            Есть новая версия на гит Где я такое говорил?
                            😄

                            в настройках

                            Ты настроил драйвер так, что бы он читал эту переменную. Удали её из конфига. `
                            Чего та недопонимаю, ставлю новый owfs.2, включаю, захожу в настройки по умолчанию, нажимаю read получаю на DS18B20 два параметра 28.FFF67D3B0400/temperature, 28.FFF67D3B0400/fasttemp

                            1 Reply Last reply Reply Quote 0
                            • Bluefox
                              Bluefox last edited by

                              @Haus:

                              @Bluefox:

                              @Haus:

                              Где я такое говорил? `
                              😄

                              в настройках

                              Ты настроил драйвер так, что бы он читал эту переменную. Удали её из конфига. Чего та недопонимаю, ставлю новый owfs.2, включаю, захожу в настройки по умолчанию, нажимаю read получаю на DS18B20 два параметра 28.FFF67D3B0400/temperature, 28.FFF67D3B0400/fasttemp
                              Нажать на удалить не пробовал?

                              Сначала создаются возможные полезные значения, а тебе выбирать, хочешь ты их читать или нет
                              48_2016-07-29_23_32_51-iobroker.admin.png

                              1 Reply Last reply Reply Quote 0
                              • H
                                Haus last edited by

                                @Bluefox:

                                @Haus:

                                @Bluefox:

                                😄

                                в настройках

                                Ты настроил драйвер так, что бы он читал эту переменную. Удали её из конфига. Чего та недопонимаю, ставлю новый owfs.2, включаю, захожу в настройки по умолчанию, нажимаю read получаю на DS18B20 два параметра 28.FFF67D3B0400/temperature, 28.FFF67D3B0400/fasttemp
                                Нажать на удалить не пробовал?

                                Сначала создаются возможные полезные значения, а тебе выбирать, хочешь ты их читать или нет `
                                Не знаю кому и зачем нужен fasttemp. Закомментировал в admin````
                                'heat_index',
                                'humidex',
                                'light',
                                'temperature',
                                //'fasttemp',
                                'set_alarm',
                                'date',

                                1 Reply Last reply Reply Quote 0
                                • J
                                  jeorgep last edited by

                                  DS2408 в OWFS:

                                  (http://owfs.org/uploads/DS2408.3.html#sect10)

                                  PIO используются для записи в них 0/1

                                  sensed используются для чтения информации с портов

                                  latch используются для получения информации об изменении состояния порта

                                  (бит 1 указывает, что состояние изменялось)

                                  Для очистки состояния latch применяется запись в любой из latch портов. Например:

                                  echo 1 > latch.0

                                  При этом очищаюся ВСЕ восемь latch портов, то-есть для сохранения информации

                                  об изменениях состояний портов со времени последней очистки - необходимо сохранить latch.ALL

                                  и лишь потом производить очистку.

                                  Перед использованием DS2408 необходимо провести ее инициализацию:

                                  echo 1 > out_of_testmode

                                  И для использования функции запись в порт - необходимо включить strobe:

                                  echo 1 > strobe

                                  В iobroker нужно использовать как минимум PIO и sensed - для возможности записи/чтения в порт.

                                  1 Reply Last reply Reply Quote 0
                                  • J
                                    jeorgep last edited by

                                    После установки версии 0.2.2 проблема с созданием объектов решилась.

                                    Но очень долгая реакция на изменение состояния порта (sensed) в DS2408,

                                    где-то 30 сек или больше, что недопустимо например для датчика движения и включения света.

                                    У меня датчики HC-SR501 подключены к портам DS2408.

                                    Параллельно запускаю скрипт:

                                    #!/bin/bash
                                    while true; do
                                      ALL=`cat /mnt/1wire/29.XXXXXX000000/sensed.ALL`
                                      echo $ALL
                                      sleep 1
                                    done
                                    

                                    И наблюдаю в закладке 'Objects' когда изменяется состояние (например value.sensed.4).

                                    Задержка до пол-минуты относительно скрипта.

                                    Реально такая задержка не позволит использовать драйвер OWFS для реакции на быстрые события.

                                    1 Reply Last reply Reply Quote 0
                                    • H
                                      Haus last edited by

                                      @jeorgep:

                                      После установки версии 0.2.2 проблема с созданием объектов решилась.

                                      Но очень долгая реакция на изменение состояния порта (sensed) в DS2408,

                                      где-то 30 сек или больше, что недопустимо например для датчика движения и включения света.

                                      У меня датчики HC-SR501 подключены к портам DS2408.

                                      Параллельно запускаю скрипт:

                                      #!/bin/bash
                                      while true; do
                                        ALL=`cat /mnt/1wire/29.XXXXXX000000/sensed.ALL`
                                        echo $ALL
                                        sleep 1
                                      done
                                      

                                      И наблюдаю в закладке 'Objects' когда изменяется состояние (например value.sensed.4).

                                      Задержка до пол-минуты относительно скрипта.

                                      Реально такая задержка не позволит использовать драйвер OWFS для реакции на быстрые события. `
                                      Привет,

                                      Может есть возможность проверить удалённое подключение или большее количество датчиков на 127.0.0.1, у меня Read addresses "Найдено 0 сенсор(a/ов).

                                      1 Reply Last reply Reply Quote 0
                                      • J
                                        jeorgep last edited by

                                        ` > Привет,

                                        Может есть возможность проверить удалённое подключение или большее количество датчиков на 127.0.0.1, у меня Read addresses "Найдено 0 сенсор(a/ов). `

                                        Привет,

                                        я не совсем понял вопрос.

                                        Если про мое подключение - используется Orange Pi+2.

                                        Как мастер - использую восьмиканальный DS2482-800 (http://datasheets.maximintegrated.com/e … 82-800.pdf).

                                        Ибо 1-wire не любит подключения звездой, а в моем случае сервер с мастером находятся посередине топологии, пришлось использовать ее.

                                        Реакция на уровне файлов OWFS или owserver неплохая - где-то на уровне секунды (точнее не замерял).

                                        Датчиков используется много разнообразных.

                                        И если для датчиков температуры, влажности, протечки воды, утечки газа - задержка в пол минуты допустима,

                                        то для включалелей света или датчиков движения на портах DS2408 - она критична.

                                        Жена не будет пол минуты после входа в помещение ждать пока загорится свет 🙂

                                        В результате параллельного запуска скрипта и привязаного обьекта в ioBroker -

                                        определил, что запаздывание от датчика движения происходит где-то до присвоения значения обьекту в ioBroker-е.

                                        То-есть скрипт уже давно показал, что состояние изменилось, а в ioBrokere оно остается неизмененным еще где-то 30 сек.

                                        Можно конечно обрабатывать состояние на уровне Bash или написать скрипт на Питоне и уже после

                                        обработки изменять состояние переменной в ioBroker - но тогда драйвер OWFS не нужен.

                                        1 Reply Last reply Reply Quote 0
                                        • A
                                          Alekseym6 last edited by

                                          у меня при записи через FS(добавил строчки в драйвер) - реакция на изменении менее 1 сек. 7 шт DS2413(движение, стиральная машина, нагреватель воды, насос подкачки воды и т.д.). порт А вход с детектора движения, В выход на реле.

                                          1 Reply Last reply Reply Quote 0
                                          • J
                                            jeorgep last edited by

                                            > у меня при записи через FS(добавил строчки в драйвер) - реакция на изменении менее 1 сек. 7 шт DS2413(движение, стиральная машина, нагреватель воды, насос подкачки воды и т.д.). порт А вход с детектора движения, В выход на реле.

                                            Клас!

                                            делись строчками в драйвере 🙂

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            783
                                            Online

                                            31.9k
                                            Users

                                            80.1k
                                            Topics

                                            1.3m
                                            Posts

                                            5
                                            74
                                            16779
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo