Navigation

    Logo
    • Register
    • Login
    • Search
    • Recent
    • Tags
    • Unread
    • Categories
    • Unreplied
    • Popular
    • GitHub
    • Docu
    • Hilfe
    1. Home
    2. Deutsch
    3. Tester
    4. Zwave 0.4

    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    Zwave 0.4

    This topic has been deleted. Only users with topic management privileges can see it.
    • Alex1808
      Alex1808 last edited by

      Bekomme Fibaro FIBEFGMS-001-ZW5 5G 4-in-1 Multisensor nicht angemeldet.. 😞 Geht das überhaupt mit dem ZME_UZB1 USB Stick?

      1 Reply Last reply Reply Quote 0
      • AlCalzone
        AlCalzone Developer last edited by

        @Bluefox:

        Habe eingepflegt. 0.4.2 Danke. `
        Ein Traum!

        @Bluefox:

        […] D.h. wenn du steuerst, dann antwortet das Gerät mit "false" zurück. Man kann das in den Logs sehen. Kannst du hier die posten? `
        Bittesehr:

        ! 2016-11-15 20:25:18.623 Info, Node003, Value::Set - COMMAND_CLASS_SWITCH_BINARY - Switch - 0 - 1 - True 2016-11-15 20:25:18.625 Info, Node003, SwitchBinary::Set - Setting node 3 to On 2016-11-15 20:25:18.626 Detail, Node003, Queuing (Send) SwitchBinaryCmd_Set (Node=3): 0x01, 0x0a, 0x00, 0x13, 0x03, 0x03, 0x25, 0x01, 0xff, 0x25, 0xb7, 0xaf 2016-11-15 20:25:18.627 Detail, Node003, Queuing (Send) SwitchBinaryCmd_Get (Node=3): 0x01, 0x09, 0x00, 0x13, 0x03, 0x02, 0x25, 0x02, 0x25, 0xb8, 0x5e 2016-11-15 20:25:18.628 Detail, 2016-11-15 20:25:18.629 Info, Node003, Sending (Send) message (Callback ID=0xb7, Expected Reply=0x13) - SwitchBinaryCmd_Set (Node=3): 0x01, 0x0a, 0x00, 0x13, 0x03, 0x03, 0x25, 0x01, 0xff, 0x25, 0xb7, 0xaf 2016-11-15 20:25:18.636 Detail, Node003, Received: 0x01, 0x04, 0x01, 0x13, 0x01, 0xe8 2016-11-15 20:25:18.638 Detail, Node003, ZW_SEND_DATA delivered to Z-Wave stack 2016-11-15 20:25:18.652 Detail, Node003, Received: 0x01, 0x07, 0x00, 0x13, 0xb7, 0x00, 0x00, 0x02, 0x5e 2016-11-15 20:25:18.653 Detail, Node003, ZW_SEND_DATA Request with callback ID 0xb7 received (expected 0xb7) 2016-11-15 20:25:18.653 Info, Node003, Request RTT 23 Average Request RTT 22 2016-11-15 20:25:18.654 Detail, Expected callbackId was received 2016-11-15 20:25:18.654 Detail, Expected reply was received 2016-11-15 20:25:18.655 Detail, Message transaction complete 2016-11-15 20:25:18.655 Detail, 2016-11-15 20:25:18.655 Detail, Node003, Removing current message 2016-11-15 20:25:18.656 Detail, 2016-11-15 20:25:18.657 Info, Node003, Sending (Send) message (Callback ID=0xb8, Expected Reply=0x04) - SwitchBinaryCmd_Get (Node=3): 0x01, 0x09, 0x00, 0x13, 0x03, 0x02, 0x25, 0x02, 0x25, 0xb8, 0x5e 2016-11-15 20:25:18.663 Detail, Node003, Received: 0x01, 0x04, 0x01, 0x13, 0x01, 0xe8 2016-11-15 20:25:18.664 Detail, Node003, ZW_SEND_DATA delivered to Z-Wave stack 2016-11-15 20:25:18.679 Detail, Node003, Received: 0x01, 0x07, 0x00, 0x13, 0xb8, 0x00, 0x00, 0x01, 0x52 2016-11-15 20:25:18.680 Detail, Node003, ZW_SEND_DATA Request with callback ID 0xb8 received (expected 0xb8) 2016-11-15 20:25:18.680 Info, Node003, Request RTT 22 Average Request RTT 22 2016-11-15 20:25:18.681 Detail, Expected callbackId was received 2016-11-15 20:25:18.688 Detail, Node003, Received: 0x01, 0x09, 0x00, 0x04, 0x00, 0x03, 0x03, 0x25, 0x03, 0xff, 0x2b 2016-11-15 20:25:18.689 Detail, 2016-11-15 20:25:18.689 Info, Node003, Response RTT 31 Average Response RTT 31 2016-11-15 20:25:18.689 Info, Node003, Received SwitchBinary report from node 3: level=On 2016-11-15 20:25:18.690 Detail, Node003, Refreshed Value: old value=false, new value=true, type=bool 2016-11-15 20:25:18.690 Detail, Node003, Changes to this value are not verified 2016-11-15 20:25:18.691 Detail, Node003, Expected reply and command class was received 2016-11-15 20:25:18.691 Detail, Node003, Message transaction complete 2016-11-15 20:25:18.691 Detail, 2016-11-15 20:25:18.692 Detail, Node003, Removing current message 2016-11-15 20:25:18.692 Detail, Node003, Notification: ValueChanged !
        Das sieht für mich nach der korrekten Antwort aus: old value=false, new value=true. Da mein Sensor plötzlich Mist baut, werde ich mal mit Adapter und OZW-Log spielen. Vielleicht stoße ich dann auch auf die Ursache dieses Problems.

        > > Wäre es möglich, das Konfigurationsfenster standardmäßig etwas größer zu gestalten? Ich muss schon scrollen, wenn ich in der Geräteliste das Aktions-Dropdown anzeigen will. `

        Screenshot? `
        Habe das Fenster inzwischen etwas größer gezogen, die Einstellung scheint ioBroker sich zu merken. Vielleicht ein Überbleibsel der alten Version, das bei der Installation nicht richtig überschrieben wurde?

        Habe mal versucht, die Abmaße aus der io-package.json herzustellen. Hier passt alles drauf, insgesamt bleibt relativ wenig Platz für die Geräteliste übrig (ca. 50%). Vielleicht kann man hier was an der Schriftgröße optimieren, insbesondere im Dropdown kann es IMO kleiner.

        1 Reply Last reply Reply Quote 0
        • Dutchman
          Dutchman Developer Most Active Administrators last edited by

          @Alex1808:

          Bekomme Fibaro FIBEFGMS-001-ZW5 5G 4-in-1 Multisensor nicht angemeldet.. 😞 Geht das überhaupt mit dem ZME_UZB1 USB Stick? `

          Ja, pass auf dass er zwave+ unterstützt.

          Also nimm am besten den G5, unterstütz alles und du kannst mit der batterie im Haus rumlaufen und alles ab zu lernen

          Das ist der fuffie Wert

          Sent from my iPhone using Tapatalk

          1 Reply Last reply Reply Quote 0
          • AlCalzone
            AlCalzone Developer last edited by

            @Bluefox:

            Habe das Problem mit dem falschen Schalter-Zustand gefunden. Das war übrigens auch die Ursache für das seltsame Verhalten meines Sensors.

            In Zeile 624-625 wird aus allen möglichen Variablentypen in "boolean" umgewandelt:

            if (stateObj.common.type === 'boolean') {
                value = value === 'true' || value === 255 || value === '255' || value === 'On' || value === 1  || value === '1';
            }
            

            Dabei ging allerdings der Fall vergessen, dass es sich bei der Variable bereits um ein Boolean handelt. In dem Fall wird value immer auf false gesetzt. Lässt sich mit einer kleinen Abfrage beheben:

            if (stateObj.common.type === 'boolean') {
            	// we might have to translate the value to boolean
            	if (typeof value !== 'boolean')
            		value = value === 'true' || value === 255 || value === '255' || value === 'On' || value === 1 || value === '1';
            }
            
            1 Reply Last reply Reply Quote 0
            • Bluefox
              Bluefox last edited by

              OK. Eingepflegt.

              Bitte vom git updaten.

              Und berichten was geht und was nicht geht.

              1 Reply Last reply Reply Quote 0
              • OstfrieseUnterwegs
                OstfrieseUnterwegs last edited by

                Kleine Verständnisfrage…

                Ich benutze

                npm install https://github.com/ioBroker/ioBroker.zwave/tarball/master --production --unsave-perm --build-from-source
                
                

                Aber damit wird jedesmal open-zwave neu installiert. Muss das so?

                1 Reply Last reply Reply Quote 0
                • AlCalzone
                  AlCalzone Developer last edited by

                  @OstfrieseUnterwegs:

                  Aber damit wird jedesmal open-zwave neu installiert. Muss das so? `
                  Würde mich auch interessieren.

                  Die Option heißt übrigens –unsafe-perm.

                  1 Reply Last reply Reply Quote 0
                  • OstfrieseUnterwegs
                    OstfrieseUnterwegs last edited by

                    > Die Option heißt übrigens –unsafe-perm.
                    Auch wieder wahr. Ich hab's mit –unsave-perm laufen lassen und es hat sich installiert. --unsafe-perm scheint also nicht notwendig zu sein. Kann aber auch sein, dass es lief, weil ich schon die 0.4.0 drauf hatte.

                    1 Reply Last reply Reply Quote 0
                    • Bluefox
                      Bluefox last edited by

                      Sollte mit

                      npm install https://github.com/ioBroker/ioBroker.zwave/tarball/master --production
                      

                      Laufen. Openzwave wird tatsächlich jedes mal neu übersetzt.

                      1 Reply Last reply Reply Quote 0
                      • Dutchman
                        Dutchman Developer Most Active Administrators last edited by

                        @Bluefox:

                        Sollte mit

                        npm install https://github.com/ioBroker/ioBroker.zwave/tarball/master --production
                        

                        Laufen. Openzwave wird tatsächlich jedes mal neu übersetzt. `

                        Und das ist auch OK, die librarys werden auch regelmäßig geupdatet und so bekommt man immer die neuste git Source von openzwave (wichtig für neue Controller & Hardware !)

                        Sent from my iPhone using Tapatalk

                        1 Reply Last reply Reply Quote 0
                        • AlCalzone
                          AlCalzone Developer last edited by

                          Endlich wieder Internet zuhause, d.h. ich konnte meinen Pi auf die neusten Adapter updaten. zWave tut bisher was es soll, bin aber noch nicht dazu gekommen, meine Greenwave-Dose zu testen. Hier erwarte ich nochmal Schwierigkeiten.

                          1 Reply Last reply Reply Quote 0
                          • Lenny.CB
                            Lenny.CB Most Active last edited by

                            @Bluefox: konntest du dir schon mal die OZW-Logs zum Rollo-Problem anschauen?

                            http://forum.iobroker.net/viewtopic.php … =40#p39974

                            1 Reply Last reply Reply Quote 0
                            • Bluefox
                              Bluefox last edited by

                              @Lenny.CB:

                              @Bluefox:

                              Hast du log dafür? ` ich versuche es mal…

                              > ****1:) Rollo oben (99) –> setze Wert 50 in Objekte --> Relais "klickt", Rollo fährt nicht, Wert geht wieder auf 99 zurück****

                              ! ````
                              2016-11-12 20:22:20.887 Info, Node002, SwitchMultilevel::Set - Setting to level 50
                              2016-11-12 20:22:20.888 Info, Node002, Duration: Default
                              2016-11-12 20:22:20.888 Detail, Node002, Queuing (Send) SwitchMultilevelCmd_Set (Node=2): 0x01, 0x0b, 0x00, 0x13, 0x02, 0x04, 0x26, 0x01, 0x32, 0xff, 0x25, 0x46, 0x68
                              2016-11-12 20:22:20.888 Detail, Node002, Queuing (Send) SwitchMultilevelCmd_Get (Node=2): 0x01, 0x09, 0x00, 0x13, 0x02, 0x02, 0x26, 0x02, 0x25, 0x47, 0xa3
                              2016-11-12 20:22:20.888 Detail,
                              2016-11-12 20:22:20.889 Info, Node002, Sending (Send) message (Callback ID=0x46, Expected Reply=0x13) - SwitchMultilevelCmd_Set (Node=2): 0x01, 0x0b, 0x00, 0x13, 0x02, 0x04, 0x26, 0x01, 0x32, 0xff, 0x25, 0x46, 0x68
                              2016-11-12 20:22:20.897 Detail, Node002, Received: 0x01, 0x04, 0x01, 0x13, 0x01, 0xe8
                              2016-11-12 20:22:20.898 Detail, Node002, ZW_SEND_DATA delivered to Z-Wave stack
                              2016-11-12 20:22:20.915 Detail, Node002, Received: 0x01, 0x07, 0x00, 0x13, 0x46, 0x00, 0x00, 0x02, 0xaf
                              2016-11-12 20:22:20.915 Detail, Node002, ZW_SEND_DATA Request with callback ID 0x46 received (expected 0x46)
                              2016-11-12 20:22:20.915 Info, Node002, Request RTT 26 Average Request RTT 26
                              2016-11-12 20:22:20.915 Detail, Expected callbackId was received
                              2016-11-12 20:22:20.915 Detail, Expected reply was received
                              2016-11-12 20:22:20.916 Detail, Message transaction complete
                              2016-11-12 20:22:20.916 Detail,
                              2016-11-12 20:22:20.916 Detail, Node002, Removing current message
                              2016-11-12 20:22:20.916 Detail,
                              2016-11-12 20:22:20.916 Info, Node002, Sending (Send) message (Callback ID=0x47, Expected Reply=0x04) - SwitchMultilevelCmd_Get (Node=2): 0x01, 0x09, 0x00, 0x13, 0x02, 0x02, 0x26, 0x02, 0x25, 0x47, 0xa3
                              2016-11-12 20:22:20.926 Detail, Node002, Received: 0x01, 0x04, 0x01, 0x13, 0x01, 0xe8
                              2016-11-12 20:22:20.926 Detail, Node002, ZW_SEND_DATA delivered to Z-Wave stack
                              2016-11-12 20:22:20.943 Detail, Node002, Received: 0x01, 0x07, 0x00, 0x13, 0x47, 0x00, 0x00, 0x02, 0xae
                              2016-11-12 20:22:20.943 Detail, Node002, ZW_SEND_DATA Request with callback ID 0x47 received (expected 0x47)
                              2016-11-12 20:22:20.943 Info, Node002, Request RTT 23 Average Request RTT 24
                              2016-11-12 20:22:20.943 Detail, Expected callbackId was received
                              2016-11-12 20:22:20.955 Detail, Node002, Received: 0x01, 0x09, 0x00, 0x04, 0x00, 0x02, 0x03, 0x26, 0x03, 0x63, 0xb5
                              2016-11-12 20:22:20.956 Detail,
                              2016-11-12 20:22:20.956 Info, Node002, Response RTT 35 Average Response RTT 36
                              2016-11-12 20:22:20.956 Info, Node002, Received SwitchMultiLevel report: level=99
                              2016-11-12 20:22:20.956 Detail, Node002, Refreshed Value: old value=99, new value=99, type=byte
                              2016-11-12 20:22:20.956 Detail, Node002, Changes to this value are not verified
                              2016-11-12 20:22:20.956 Detail, Node002, Expected reply and command class was received
                              2016-11-12 20:22:20.957 Detail, Node002, Message transaction complete
                              2016-11-12 20:22:20.957 Detail,
                              2016-11-12 20:22:20.957 Detail, Node002, Removing current message
                              2016-11-12 20:22:20.957 Detail, Node002, Notification: ValueChanged
                              2016-11-12 20:22:22.976 Detail, Node002, Received: 0x01, 0x09, 0x00, 0x04, 0x00, 0x02, 0x03, 0x26, 0x03, 0x63, 0xb5
                              2016-11-12 20:22:22.976 Detail,
                              2016-11-12 20:22:22.977 Info, Node002, Received SwitchMultiLevel report: level=99
                              2016-11-12 20:22:22.977 Detail, Node002, Refreshed Value: old value=99, new value=99, type=byte
                              2016-11-12 20:22:22.977 Detail, Node002, Changes to this value are not verified
                              2016-11-12 20:22:22.977 Detail, Node002, Notification: ValueChanged
                              2016-11-12 20:22:23.001 Detail, Node002, Received: 0x01, 0x0c, 0x00, 0x04, 0x00, 0x02, 0x06, 0x31, 0x05, 0x04, 0x22, 0x00, 0x00, 0xe1
                              2016-11-12 20:22:23.001 Detail,
                              2016-11-12 20:22:23.001 Info, Node002, Received SensorMultiLevel report from node 2, instance 1, Power: value=0.0W
                              2016-11-12 20:22:23.001 Detail, Node002, Refreshed Value: old value=0.0, new value=0.0, type=decimal
                              2016-11-12 20:22:23.001 Detail, Node002, Changes to this value are not verified
                              2016-11-12 20:22:23.002 Detail, Node002, Notification: ValueChanged

                              
                                ` > ****2:) Rollo oben (99) –> setze Wert 0 in Objekte --> Relais "klickt", Rollo fährt ganz runter, Wert geht auf 0**** `  
                              
                              >! ````
                              2016-11-12 20:25:31.015 Info, Node002, SwitchMultilevel::Set - Setting to level 0
                              2016-11-12 20:25:31.015 Info, Node002,   Duration: Default
                              2016-11-12 20:25:31.015 Detail, Node002, Queuing (Send) SwitchMultilevelCmd_Set (Node=2): 0x01, 0x0b, 0x00, 0x13, 0x02, 0x04, 0x26, 0x01, 0x00, 0xff, 0x25, 0x48, 0x54
                              2016-11-12 20:25:31.015 Detail, Node002, Queuing (Send) SwitchMultilevelCmd_Get (Node=2): 0x01, 0x09, 0x00, 0x13, 0x02, 0x02, 0x26, 0x02, 0x25, 0x49, 0xad
                              2016-11-12 20:25:31.015 Detail, 
                              2016-11-12 20:25:31.016 Info, Node002, Sending (Send) message (Callback ID=0x48, Expected Reply=0x13) - SwitchMultilevelCmd_Set (Node=2): 0x01, 0x0b, 0x00, 0x13, 0x02, 0x04, 0x26, 0x01, 0x00, 0xff, 0x25, 0x48, 0x54
                              2016-11-12 20:25:31.025 Detail, Node002,   Received: 0x01, 0x04, 0x01, 0x13, 0x01, 0xe8
                              2016-11-12 20:25:31.025 Detail, Node002,   ZW_SEND_DATA delivered to Z-Wave stack
                              2016-11-12 20:25:31.042 Detail, Node002,   Received: 0x01, 0x07, 0x00, 0x13, 0x48, 0x00, 0x00, 0x02, 0xa1
                              2016-11-12 20:25:31.043 Detail, Node002,   ZW_SEND_DATA Request with callback ID 0x48 received (expected 0x48)
                              2016-11-12 20:25:31.043 Info, Node002, Request RTT 26 Average Request RTT 25
                              2016-11-12 20:25:31.043 Detail,   Expected callbackId was received
                              2016-11-12 20:25:31.043 Detail,   Expected reply was received
                              2016-11-12 20:25:31.043 Detail,   Message transaction complete
                              2016-11-12 20:25:31.043 Detail, 
                              2016-11-12 20:25:31.044 Detail, Node002, Removing current message
                              2016-11-12 20:25:31.044 Detail, 
                              2016-11-12 20:25:31.044 Info, Node002, Sending (Send) message (Callback ID=0x49, Expected Reply=0x04) - SwitchMultilevelCmd_Get (Node=2): 0x01, 0x09, 0x00, 0x13, 0x02, 0x02, 0x26, 0x02, 0x25, 0x49, 0xad
                              2016-11-12 20:25:31.057 Detail, Node002,   Received: 0x01, 0x04, 0x01, 0x13, 0x01, 0xe8
                              2016-11-12 20:25:31.058 Detail, Node002,   ZW_SEND_DATA delivered to Z-Wave stack
                              2016-11-12 20:25:31.071 Detail, Node002,   Received: 0x01, 0x07, 0x00, 0x13, 0x49, 0x00, 0x00, 0x02, 0xa0
                              2016-11-12 20:25:31.071 Detail, Node002,   ZW_SEND_DATA Request with callback ID 0x49 received (expected 0x49)
                              2016-11-12 20:25:31.071 Info, Node002, Request RTT 26 Average Request RTT 25
                              2016-11-12 20:25:31.071 Detail,   Expected callbackId was received
                              2016-11-12 20:25:31.080 Detail, Node002,   Received: 0x01, 0x09, 0x00, 0x04, 0x00, 0x02, 0x03, 0x26, 0x03, 0x63, 0xb5
                              2016-11-12 20:25:31.081 Detail, 
                              2016-11-12 20:25:31.081 Info, Node002, Response RTT 36 Average Response RTT 36
                              2016-11-12 20:25:31.081 Info, Node002, Received SwitchMultiLevel report: level=99
                              2016-11-12 20:25:31.081 Detail, Node002, Refreshed Value: old value=99, new value=99, type=byte
                              2016-11-12 20:25:31.081 Detail, Node002, Changes to this value are not verified
                              2016-11-12 20:25:31.081 Detail, Node002,   Expected reply and command class was received
                              2016-11-12 20:25:31.081 Detail, Node002,   Message transaction complete
                              2016-11-12 20:25:31.081 Detail, 
                              2016-11-12 20:25:31.081 Detail, Node002, Removing current message
                              2016-11-12 20:25:31.082 Detail, Node002, Notification: ValueChanged
                              2016-11-12 20:25:32.188 Detail, Node002,   Received: 0x01, 0x0c, 0x00, 0x04, 0x00, 0x02, 0x06, 0x31, 0x05, 0x04, 0x22, 0x04, 0xdd, 0x38
                              2016-11-12 20:25:32.188 Detail, 
                              2016-11-12 20:25:32.188 Info, Node002, Received SensorMultiLevel report from node 2, instance 1, Power: value=124.5W
                              2016-11-12 20:25:32.189 Detail, Node002, Refreshed Value: old value=0.0, new value=124.5, type=decimal
                              2016-11-12 20:25:32.189 Detail, Node002, Changes to this value are not verified
                              2016-11-12 20:25:32.189 Detail, Node002, Notification: ValueChanged
                              2016-11-12 20:25:47.501 Detail, Node002,   Received: 0x01, 0x0c, 0x00, 0x04, 0x00, 0x02, 0x06, 0x31, 0x05, 0x04, 0x22, 0x00, 0x00, 0xe1
                              2016-11-12 20:25:47.501 Detail, 
                              2016-11-12 20:25:47.502 Info, Node002, Received SensorMultiLevel report from node 2, instance 1, Power: value=0.0W
                              2016-11-12 20:25:47.502 Detail, Node002, Refreshed Value: old value=124.5, new value=0.0, type=decimal
                              2016-11-12 20:25:47.502 Detail, Node002, Changes to this value are not verified
                              2016-11-12 20:25:47.502 Detail, Node002, Notification: ValueChanged
                              2016-11-12 20:25:48.661 Detail, Node002,   Received: 0x01, 0x09, 0x00, 0x04, 0x00, 0x02, 0x03, 0x26, 0x03, 0x00, 0xd6
                              2016-11-12 20:25:48.661 Detail, 
                              2016-11-12 20:25:48.661 Info, Node002, Received SwitchMultiLevel report: level=0
                              2016-11-12 20:25:48.661 Detail, Node002, Refreshed Value: old value=99, new value=0, type=byte
                              2016-11-12 20:25:48.662 Detail, Node002, Changes to this value are not verified
                              2016-11-12 20:25:48.662 Detail, Node002, Notification: ValueChanged
                              2016-11-12 20:25:48.681 Detail, Node002,   Received: 0x01, 0x0c, 0x00, 0x04, 0x00, 0x02, 0x06, 0x31, 0x05, 0x04, 0x22, 0x00, 0x00, 0xe1
                              2016-11-12 20:25:48.681 Detail, 
                              2016-11-12 20:25:48.681 Info, Node002, Received SensorMultiLevel report from node 2, instance 1, Power: value=0.0W
                              2016-11-12 20:25:48.682 Detail, Node002, Refreshed Value: old value=0.0, new value=0.0, type=decimal
                              2016-11-12 20:25:48.682 Detail, Node002, Changes to this value are not verified
                              2016-11-12 20:25:48.682 Detail, Node002, Notification: ValueChanged
                              

                              > ****3:) Rollo unten (0) –> setze Wert 50 in Objekte --> Relais "klickt", Rollo fährt ganz hoch, Wert geht auf 99****

                              ! 2016-11-12 20:27:09.764 Info, Node002, SwitchMultilevel::Set - Setting to level 50 2016-11-12 20:27:09.764 Info, Node002, Duration: Default 2016-11-12 20:27:09.764 Detail, Node002, Queuing (Send) SwitchMultilevelCmd_Set (Node=2): 0x01, 0x0b, 0x00, 0x13, 0x02, 0x04, 0x26, 0x01, 0x32, 0xff, 0x25, 0x4a, 0x64 2016-11-12 20:27:09.764 Detail, Node002, Queuing (Send) SwitchMultilevelCmd_Get (Node=2): 0x01, 0x09, 0x00, 0x13, 0x02, 0x02, 0x26, 0x02, 0x25, 0x4b, 0xaf 2016-11-12 20:27:09.765 Detail, 2016-11-12 20:27:09.765 Info, Node002, Sending (Send) message (Callback ID=0x4a, Expected Reply=0x13) - SwitchMultilevelCmd_Set (Node=2): 0x01, 0x0b, 0x00, 0x13, 0x02, 0x04, 0x26, 0x01, 0x32, 0xff, 0x25, 0x4a, 0x64 2016-11-12 20:27:09.774 Detail, Node002, Received: 0x01, 0x04, 0x01, 0x13, 0x01, 0xe8 2016-11-12 20:27:09.774 Detail, Node002, ZW_SEND_DATA delivered to Z-Wave stack 2016-11-12 20:27:09.792 Detail, Node002, Received: 0x01, 0x07, 0x00, 0x13, 0x4a, 0x00, 0x00, 0x02, 0xa3 2016-11-12 20:27:09.792 Detail, Node002, ZW_SEND_DATA Request with callback ID 0x4a received (expected 0x4a) 2016-11-12 20:27:09.792 Info, Node002, Request RTT 26 Average Request RTT 25 2016-11-12 20:27:09.792 Detail, Expected callbackId was received 2016-11-12 20:27:09.792 Detail, Expected reply was received 2016-11-12 20:27:09.793 Detail, Message transaction complete 2016-11-12 20:27:09.793 Detail, 2016-11-12 20:27:09.793 Detail, Node002, Removing current message 2016-11-12 20:27:09.793 Detail, 2016-11-12 20:27:09.793 Info, Node002, Sending (Send) message (Callback ID=0x4b, Expected Reply=0x04) - SwitchMultilevelCmd_Get (Node=2): 0x01, 0x09, 0x00, 0x13, 0x02, 0x02, 0x26, 0x02, 0x25, 0x4b, 0xaf 2016-11-12 20:27:09.802 Detail, Node002, Received: 0x01, 0x04, 0x01, 0x13, 0x01, 0xe8 2016-11-12 20:27:09.802 Detail, Node002, ZW_SEND_DATA delivered to Z-Wave stack 2016-11-12 20:27:09.819 Detail, Node002, Received: 0x01, 0x07, 0x00, 0x13, 0x4b, 0x00, 0x00, 0x03, 0xa3 2016-11-12 20:27:09.819 Detail, Node002, ZW_SEND_DATA Request with callback ID 0x4b received (expected 0x4b) 2016-11-12 20:27:09.819 Info, Node002, Request RTT 25 Average Request RTT 25 2016-11-12 20:27:09.819 Detail, Expected callbackId was received 2016-11-12 20:27:09.833 Detail, Node002, Received: 0x01, 0x09, 0x00, 0x04, 0x00, 0x02, 0x03, 0x26, 0x03, 0x00, 0xd6 2016-11-12 20:27:09.833 Detail, 2016-11-12 20:27:09.834 Info, Node002, Response RTT 39 Average Response RTT 37 2016-11-12 20:27:09.834 Info, Node002, Received SwitchMultiLevel report: level=0 2016-11-12 20:27:09.834 Detail, Node002, Refreshed Value: old value=0, new value=0, type=byte 2016-11-12 20:27:09.834 Detail, Node002, Changes to this value are not verified 2016-11-12 20:27:09.834 Detail, Node002, Expected reply and command class was received 2016-11-12 20:27:09.834 Detail, Node002, Message transaction complete 2016-11-12 20:27:09.835 Detail, 2016-11-12 20:27:09.835 Detail, Node002, Removing current message 2016-11-12 20:27:09.835 Detail, Node002, Notification: ValueChanged 2016-11-12 20:27:10.937 Detail, Node002, Received: 0x01, 0x0c, 0x00, 0x04, 0x00, 0x02, 0x06, 0x31, 0x05, 0x04, 0x22, 0x04, 0xe6, 0x03 2016-11-12 20:27:10.938 Detail, 2016-11-12 20:27:10.938 Info, Node002, Received SensorMultiLevel report from node 2, instance 1, Power: value=125.4W 2016-11-12 20:27:10.938 Detail, Node002, Refreshed Value: old value=0.0, new value=125.4, type=decimal 2016-11-12 20:27:10.938 Detail, Node002, Changes to this value are not verified 2016-11-12 20:27:10.938 Detail, Node002, Notification: ValueChanged 2016-11-12 20:27:26.252 Detail, Node002, Received: 0x01, 0x0c, 0x00, 0x04, 0x00, 0x02, 0x06, 0x31, 0x05, 0x04, 0x22, 0x00, 0x00, 0xe1 2016-11-12 20:27:26.253 Detail, 2016-11-12 20:27:26.253 Info, Node002, Received SensorMultiLevel report from node 2, instance 1, Power: value=0.0W 2016-11-12 20:27:26.253 Detail, Node002, Refreshed Value: old value=125.4, new value=0.0, type=decimal 2016-11-12 20:27:26.253 Detail, Node002, Changes to this value are not verified 2016-11-12 20:27:26.253 Detail, Node002, Notification: ValueChanged 2016-11-12 20:27:27.583 Detail, Node002, Received: 0x01, 0x09, 0x00, 0x04, 0x00, 0x02, 0x03, 0x26, 0x03, 0x63, 0xb5 2016-11-12 20:27:27.584 Detail, 2016-11-12 20:27:27.584 Info, Node002, Received SwitchMultiLevel report: level=99 2016-11-12 20:27:27.584 Detail, Node002, Refreshed Value: old value=0, new value=99, type=byte 2016-11-12 20:27:27.584 Detail, Node002, Changes to this value are not verified 2016-11-12 20:27:27.585 Detail, Node002, Notification: ValueChanged 2016-11-12 20:27:27.602 Detail, Node002, Received: 0x01, 0x0c, 0x00, 0x04, 0x00, 0x02, 0x06, 0x31, 0x05, 0x04, 0x22, 0x00, 0x00, 0xe1 2016-11-12 20:27:27.603 Detail, 2016-11-12 20:27:27.603 Info, Node002, Received SensorMultiLevel report from node 2, instance 1, Power: value=0.0W 2016-11-12 20:27:27.603 Detail, Node002, Refreshed Value: old value=0.0, new value=0.0, type=decimal 2016-11-12 20:27:27.603 Detail, Node002, Changes to this value are not verified 2016-11-12 20:27:27.604 Detail, Node002, Notification: ValueChanged `
                              Wenn das tatsächlich die Meldungen aus OZW sind, dann meine Frage: geht das überhaupt?

                              So weit ich sehen kann, dass Kommando kommt schon an:
                              ` > Info, Node002, SwitchMultilevel::Set - Setting to level 50

                              …

                              Info, Node002, Received SwitchMultiLevel report: level=99 `
                              Dein Gerät meldet 99 zurück auch nach 2 Sekunden.

                              1 Reply Last reply Reply Quote 0
                              • Lenny.CB
                                Lenny.CB Most Active last edited by

                                @Bluefox:

                                So weit ich sehen kann, dass Kommando kommt schon an:
                                ` > Info, Node002, SwitchMultilevel::Set - Setting to level 50

                                …

                                Info, Node002, Received SwitchMultiLevel report: level=99 Dein Gerät meldet 99 zurück auch nach 2 Sekunden.

                                und genau da ist das Problem. Ich denke das das Gerät "nur" unten oder oben kennt, bzw. 0 oder 99.

                                Vielleicht liegts auch an den Configurationseinstellungen beim Includieren.

                                Ich werde jetzt die Config in FHEM prüfen. Da hat es zumindest perfekt funktioniert. Mal schauen ob ich da ein OZW-Log rausbekomme.

                                1 Reply Last reply Reply Quote 0
                                • Patrick
                                  Patrick last edited by

                                  ich schaffe es leider auch nicht den Adapter zu installieren

                                  bei mir kommt immer dieser Fehler

                                  ! ````
                                  C:\Program Files\IO BROKER\ioBroker>npm install https://github.com/ioBroker/ioBroker.zwave/tarball/master --production
                                  |
                                  iobroker.zwave@0.4.2 preinstall C:\Program Files\IO BROKER\ioBroker\node_modules\iobroker.zwave
                                  node preinstall.js
                                  ! win32 is currently not supported

                                  openzwave-shared@1.2.0 preinstall C:\Program Files\IO BROKER\ioBroker\node_modules\iobroker.zwave\node_modules\openzwave-shared
                                  node lib/install-ozw.js
                                  ! Installing Open Z-Wave
                                  Installing dependencies to C:\Users\rickfl\AppData\Local\Temp\ozwinstall-9bksiu4ygb9
                                  npm WARN deprecated wrench@1.5.9: wrench.js is deprecated! You should check out fs-extra (https://github.com/jprichardson/node-fs-extra) for any operations you were using wrench for. Thanks for all the usage over the years.
                                  module.js:327
                                  throw err;
                                  ^
                                  ! Error: Cannot find module 'C:\Users\rickfl\AppData\Local\Temp\ozwinstall-9bksiu4ygb9/node_modules/request'
                                  at Function.Module._resolveFilename (module.js:325:15)
                                  at Function.Module._load (module.js:276:25)
                                  at Module.require (module.js:353:17)
                                  at require (internal/module.js:12:17)
                                  at Module.module.exports (C:\Program Files\IO BROKER\ioBroker\node_modules\iobroker.zwave\node_modules\openzwave-shared\lib\install-ozw.js:165:13)
                                  at Object. <anonymous>(C:\Program Files\IO BROKER\ioBroker\node_modules\iobroker.zwave\node_modules\openzwave-shared\lib\install-ozw.js:220:12)
                                  at Module._compile (module.js:409:26)
                                  at Object.Module._extensions..js (module.js:416:10)
                                  at Module.load (module.js:343:32)
                                  at Function.Module._load (module.js:300:12)
                                  npm ERR! Windows_NT 10.0.10586
                                  npm ERR! argv "C:\Program Files\nodejs\node.exe" "C:\Program Files\nodejs\node_modules\npm\bin\npm-cli.js" "install" "https://github.com/ioBroker/ioBroker.zwave/tarball/master" "--production"
                                  npm ERR! node v4.6.1
                                  npm ERR! npm v2.15.9
                                  npm ERR! code ELIFECYCLE
                                  ! npm ERR! openzwave-shared@1.2.0 preinstall: node lib/install-ozw.js
                                  npm ERR! Exit status 1
                                  npm ERR!
                                  npm ERR! Failed at the openzwave-shared@1.2.0 preinstall script 'node lib/install-ozw.js'.
                                  npm ERR! This is most likely a problem with the openzwave-shared package,
                                  npm ERR! not with npm itself.
                                  npm ERR! Tell the author that this fails on your system:
                                  npm ERR! node lib/install-ozw.js
                                  npm ERR! You can get information on how to open an issue for this project with:
                                  npm ERR! npm bugs openzwave-shared
                                  npm ERR! Or if that isn't available, you can get their info via:
                                  npm ERR!
                                  npm ERR! npm owner ls openzwave-shared
                                  npm ERR! There is likely additional logging output above.
                                  ! npm ERR! Please include the following file with any support request:
                                  npm ERR! C:\Program Files\IO BROKER\ioBroker\npm-debug.log
                                  ! C:\Program Files\IO BROKER\ioBroker></anonymous>

                                  1 Reply Last reply Reply Quote 0
                                  • Bluefox
                                    Bluefox last edited by

                                    > win32 is currently not supported
                                    Hm

                                    1 Reply Last reply Reply Quote 0
                                    • Patrick
                                      Patrick last edited by

                                      @Bluefox:

                                      > win32 is currently not supported
                                      Hm `

                                      das Komische ist das ich es schon mal geschafft habe den Adapter zu installieren nach dem er aber nicht gestartet ist und den USB Stick nicht angezeigt hat habe ich ihn neu installieren wollen

                                      1 Reply Last reply Reply Quote 0
                                      • Lenny.CB
                                        Lenny.CB Most Active last edited by

                                        @Bluefox:

                                        ` > Info, Node002, SwitchMultilevel::Set - Setting to level 50

                                        …

                                        Info, Node002, Received SwitchMultiLevel report: level=99 Dein Gerät meldet 99 zurück auch nach 2 Sekunden.
                                        Problem ist gelößt. ich hatte nun mal den Parameter 29 auf "Start calibration process(1)" gesetzt. Danach wurden alle Befehle zwischen 0 und 99 korrekt angenommen und verarbeitet.

                                        Ich bin immer davon ausgegangen, dass die Kalibrierung nur einmalig nach der Installation der Module erfolgen muss.

                                        1 Reply Last reply Reply Quote 0
                                        • Bluefox
                                          Bluefox last edited by

                                          @Lenny.CB:

                                          @Bluefox:

                                          ` > Info, Node002, SwitchMultilevel::Set - Setting to level 50

                                          …

                                          Info, Node002, Received SwitchMultiLevel report: level=99 Dein Gerät meldet 99 zurück auch nach 2 Sekunden.
                                          Problem ist gelößt. ich hatte nun mal den Parameter 29 auf "Start calibration process(1)" gesetzt. Danach wurden alle Befehle zwischen 0 und 99 korrekt angenommen und verarbeitet.

                                          Ich bin immer davon ausgegangen, dass die Kalibrierung nur einmalig nach der Installation der Module erfolgen muss. `
                                          Hast du die Kalibrierung über iob gestartet?

                                          Oder braucht man dafür extra Tool?

                                          1 Reply Last reply Reply Quote 0
                                          • Lenny.CB
                                            Lenny.CB Most Active last edited by

                                            @Bluefox:

                                            Hast du die Kalibrierung über iob gestartet?

                                            Oder braucht man dafür extra Tool? `
                                            habe das über ioB gemacht. In den Objekten –> zwave.0 --> NODE2 --> CONFIGURATION den Parameter 29 (Forced_Roller_Shutter_calibration) gesetzt, Rollo fährt hoch-runter-hoch... fertig...

                                            983_zwave.jpg
                                            im Bild ist Default(0) = "normalmodus" und (1) ist Kalibrierung

                                            Danach ging alles prima… 😄

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            764
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            16
                                            142
                                            21342
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo