Navigation

    Logo
    • Register
    • Login
    • Search
    • Recent
    • Tags
    • Unread
    • Categories
    • Unreplied
    • Popular
    • GitHub
    • Docu
    • Hilfe
    1. Home
    2. Deutsch
    3. Error/Bug
    4. HM-Rega: invalid response und kurz ReGaHSS down / gelb

    NEWS

    • Neuer Blog: Fotos und Eindrücke aus Solingen

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    HM-Rega: invalid response und kurz ReGaHSS down / gelb

    This topic has been deleted. Only users with topic management privileges can see it.
    • K
      klassisch Most Active @nik82 last edited by klassisch

      @nik82 10 mal hatte ich nie. ein paar mal schon.

      Welche Adapter-Versionen hast Du und welche CCU-Version?
      Edit CCU steht oben 3.55.5 Raspimatic.
      Ich fahre piVCCU
      Seit eben 3.55.10

      nik82 1 Reply Last reply Reply Quote 0
      • nik82
        nik82 Most Active @klassisch last edited by

        @klassisch

        Alles auf aktuellen Stand weil ich jedesmal hoffe das Problem zu beheben.
        Leider kann ich gar nicht sagen wie lange ich das Problem schon habe, weil mir das jetzt erst aufgefallen ist und ich dann im Log sah das es schon sehr lange so ist.

        Bin wieder auf Raspberrymatic, weil es mit der Original CCU3 Firmware ja auch das Problem gab. Momentan die 3.55.5.20201226

        HM-Rega auf aktuell auf 3.0.7 und RPC auf 1.14.31

        K 1 Reply Last reply Reply Quote 0
        • K
          klassisch Most Active @nik82 last edited by

          @nik82 Dann bist Du Adapterseitig moderner als ich.
          Habe gerade mal die Ereignisanzeige studiert.
          Sieht so aus, als habe ich mich am 11.1. eingeloggt und anscheinend wurde ein Win Neustart durchgeführt.
          Langsam dämmert es.
          Das hängt wohl tatsächlich mit dem Update am 9.1. zusammen.
          Habe das Update wohl am 9.1. angestoßen aber den zugehörigen Neustart erst am 11. 1. frühmorgens in der Schwachlastzeit angestoßen.
          Vielleicht hat das Update doch etwas beigetragen. Denn im HM-Forum ist keiner auf das Thema eingegangen.
          Sehr ominös.
          Aber die Abhängigkeit von der HM Firmware war reproduzierbar.

          nik82 1 Reply Last reply Reply Quote 0
          • nik82
            nik82 Most Active @klassisch last edited by

            @klassisch
            Naja, obs an den Windows Update liegt, kann ich dir dann sagen, weil ich gerade installiere.
            Hast du momentan auch noch die 1909 drauf?
            Habe jetzt die Win-Updates installiert, allerdings ist das Update von dir nicht dabei und jetzt würde er mir nur das Upgrade auf 20H2 anbieten, dass lasse ich aber jetzt mal weg, erst schau ich ob der Fehler nochmal kommt und dann kann ich immer noch das komplette Upgrade installieren.

            K 1 Reply Last reply Reply Quote 0
            • K
              klassisch Most Active @nik82 last edited by

              @nik82 Meine Version
              aa72e6ea-2dd4-417b-8f6d-b2bf3850778b-image.png
              Das 20H2 lassen wir erst mal weiter reifen. War wohl nicht so glücklich. Das muß noch nicht auf die Produktivmaschine. Wurde mir auch noch nicht angeboten. Ist ein i5-6300U.
              20H2 Habe ich bisher nur auf einem reinen "Office-Rechner" mit i5-5300.
              Auch für meinen Arbeitsrechner mit i7-7.... wurde das noch nicht angeboten.
              Unterm Strich bin ich aber mit den Win Rechnern deutlich zufriedener als mit den Linux-Frickel SBCs. Läuft bisher alles stabil.
              Vielleicht wäre auch eine richtige Linux-Desktop Distribution wie MINT denkbar. Aber mein ganzer Datenbestand ist auf NTFS und eben auch viele Daten von Win Applikationen und ein entsprechendes Toolset. Damit liegt für mich Windows näher als Linux. Außerdem laufen auf meinem ioBroker Rechner noch andere 24/7 Win Applikationen.

              nik82 1 Reply Last reply Reply Quote 0
              • nik82
                nik82 Most Active @klassisch last edited by

                @klassisch
                Bei mir genau das gleiche, ich habe einen i7 Nuc als Arbeits-PC, der läuft eh 24/7 und die Iobroker Installation läuft bis jetzt echt tadellos.

                Habe jetzt dieses Build, bisschen neuer als deines:

                4de0eb71-9d31-4317-8515-c3d7acf32472-image.png

                Jetzt einfach mal abwarten, ich gebe Bescheid sobald der Fehler wieder auftritt 🙂

                1 Reply Last reply Reply Quote 0
                • K
                  klassisch Most Active last edited by klassisch

                  Vielleicht hilft auch mein Watchdog-Skript

                  // Watchdog to monitor an alive signal of the CCU
                  //
                  const idWatchdogCcuMa = 'hm-rega.0.23614'/*Watchdog-CCU*/; 
                  const timeoutCCUWatchdog = 2 * 60*1000; // 2 minuten in ms
                  
                  const regaConnectionId = 'hm-rega.0.info.connection';
                  const rpc0ConnectionId = 'hm-rpc.0.info.connection';
                  const rpc1ConnectionId = 'hm-rpc.1.info.connection'; // for CUxD
                  const rpcTimeout = 1000; // granted timeout without mail
                  const maxWarningsPerDay = 10; 
                  
                  var timerCcuMa = null;
                  var timerHmRPC1 = null;
                  var numberOfWarningsToday = 0;
                  
                  const emailFrom = globalEmailFrom;
                  const emailTo = globalEmailTo;
                  
                  on({id: idWatchdogCcuMa, change: 'ne'}, function() { // löst bei jeder Aktualisierung aus
                     if(timerCcuMa) clearTimeout(timerCcuMa);       // laufender Timer wird gestoppt
                     timerCcuMa = setTimeout(function() {      // Neustart Timer
                        numberOfWarningsToday ++; 
                        if (numberOfWarningsToday <= maxWarningsPerDay){ 
                            sendTo('email', {from: emailFrom, to: emailTo, subject: '!!HM CCU stucks', text: 'Timeout CCU HM . Warning ' + numberOfWarningsToday +' of ' + maxWarningsPerDay +' .Monitored by ioBroker'});  // Aktion, wenn  Verzoegerungszeit abgelaufen ist
                        }
                     }, timeoutCCUWatchdog); 
                  });
                  
                  
                  on({id: regaConnectionId, change:'ne'}, function(dp) { // löst bei jeder Aktualisierung aus
                      numberOfWarningsToday ++;
                      if (numberOfWarningsToday <= maxWarningsPerDay){ // limits the messages per day 
                  
                       if (dp.state.val){
                           sendTo('email', {from: emailFrom, to: emailTo, subject: '!!HM CCU Rega connected ', text: 'Rega CCU HM  connected. Warning' + numberOfWarningsToday +' of ' + maxWarningsPerDay +' . Monitored by ioBroker'});  
                        }
                        else 
                       {
                            sendTo('email', {from: emailFrom, to: emailTo, subject: '!!HM CCU Rega stucks', text: 'Rega CCU HM  not connected. Warning ' + numberOfWarningsToday +' of ' + maxWarningsPerDay +' .  Monitored by ioBroker'});  
                       }
                      } // end if (numberOfWarningsToday <= maxWarningsPerDay)
                  });
                  
                  
                  on({id: rpc0ConnectionId, change:'ne'}, function(dp) { // löst bei jeder Aktualisierung aus
                      numberOfWarningsToday ++;
                      if (numberOfWarningsToday <= maxWarningsPerDay){ 
                        if (dp.state.val){
                          sendTo('email', {from: emailFrom, to: emailTo, subject: '!!HM CCU Rpc0 connected', text: 'Rpc0 CCU HM  connected.. Warning ' + numberOfWarningsToday +' of ' + maxWarningsPerDay +' . Monitored by ioBroker'});  
                        }
                        else 
                        {
                              sendTo('email', {from: emailFrom, to: emailTo, subject: '!!HM CCU Rpc0 stucks', text: 'Rpc0 CCU HM  not connected. Monitored by ioBroker'}); 
                        }
                      }// ent if (numberOfWarnings)
                  });
                  
                  on({id: rpc1ConnectionId, change:'ne'}, function(dp) { // löst bei jeder Aktualisierung aus
                     numberOfWarningsToday ++;
                     if (numberOfWarningsToday <= maxWarningsPerDay){  
                     // HMRPC1 is prone to short connection losses < 1 second once or twice a day
                       if(timerHmRPC1) clearTimeout(timerHmRPC1);       // laufender Timer wird gestoppt
                         timerHmRPC1 = setTimeout(function() {      // Neustart Timer    
                               if (getState(rpc1ConnectionId).val){
                            sendTo('email', {from: emailFrom, to: emailTo, subject: '!!HM CCU Rpc1 connected', text: 'Rpc1 CCU HM  connected.. Warning ' + numberOfWarningsToday +' of ' + maxWarningsPerDay +' .  Monitored by ioBroker'});   
                          }
                          else 
                          {
                              sendTo('email', {from: emailFrom, to: emailTo, subject: '!!HM CCU Rpc1 stucks', text: 'Rpc1 CCU HM  not connected.. Warning ' + numberOfWarningsToday +' of ' + maxWarningsPerDay +' .  Monitored by ioBroker'});  
                          }
                       }, rpcTimeout);  // timeout time
                     } // end if numberOfWarningsToday
                  });
                  
                  schedule({hour: 0, minute: 11}, function(){ // dayOfWeek: 0: sunday 
                      numberOfWarningsToday = 0;
                  });
                  
                  
                  
                  // end
                  
                  
                  
                  
                  
                  
                  

                  Auf der CCU gibt es dazu
                  Oszillator
                  f26f48f4-e2e6-43bc-ad1d-b5128f2ee888-image.png
                  mit
                  6ba7611c-9de3-46c0-ba2e-62fdc5f2a504-image.png

                  Und die Überwachung des ioBroker übernimmt auf der CCU
                  8a082a5b-8a75-40b3-b93c-40a841999a48-image.png

                  Edit: Dazu gibt es auf der CCU folgende Systemvariablen
                  e25b380b-5136-42ec-8917-f65eb3e6605d-image.png
                  und natürlich auch einen Oszillatior auf dem ioBroker. Ok, hätte man auch in das Watchdog-Skript einbauen können.....

                  // generates Oszillations to be monitored by the CCU
                  const idWatchdogToken = 'hm-rega.0.47538'/*Watchdog-ioBroker*/
                  
                  var token = getState (idWatchdogToken).val;
                  
                  //first live signal immediately after start
                     token = ! token;
                     setState (idWatchdogToken, token); // toggling and writing back
                  
                  // then continuing according schedule 
                  schedule('* * * * *', function() { // each complete minute
                     token = ! token;
                     setState (idWatchdogToken, token); // toggling and writing back
                     });
                  
                  

                  nik82 1 Reply Last reply Reply Quote 1
                  • nik82
                    nik82 Most Active @klassisch last edited by

                    @klassisch
                    Hi, also Windows Updates haben nichts geholfen, bei mir ist der Fehler wieder seit gestern 3 mal aufgetreten.
                    Ich mache jetzt mal ein Downgrade auf RaspberryMatic-3.53.30.20201024-ccu3.tgz, da du sagtest dort trat es bei dir nicht auf, dass interessiert mich jetzt schon ob das bei mir auch so ist.
                    Werde dann wieder Bescheid geben 🙂

                    K 1 Reply Last reply Reply Quote 0
                    • K
                      klassisch Most Active @nik82 last edited by

                      @nik82 vielen Dank für die RM.
                      Nur zur Info. Ich verwende keine Raspimatic, sondern piVCCU. Die piVCCU betreibt die originale CCU3 Firmware in einem Container. Das war und ist eine Möglichkeit, auch andere HW als die frühere CCU2 HW oder die heutige Raspi-HW zu verwenden.
                      Bin da noch zu CCU2 Zeiten mit einem Orange PI +2e eingestiegen, weil der die (zumindest damals) fehleranlällige SD-Karte durch ein eMMC ersetzt hat, mehr Speicher hatte etc. Das habe ich irgendwann mal auf (piV)CCU3 umgestellt. Und da das stabil läuft, bin ich dabei geblieben. Wachstum findet bei mir eh meist außerhalb von HM statt, also gab es für mich kein Grund zum Wechsel. piVCCU ist zur regulären CCU-SW auch Backup-kompatibel (da ja identisch), was mir wichtig ist. Bei Raspimatic war das damals nicht so. Wie es heute ist, weiß ich nicht. So lange es läuft....

                      Habe gestern Abend auch nochmals irgendeinen Win Treiber aktualisiert und eben auch die CCU3 3.55.10 installiert.
                      Bisher ist Ruhe. Hatte allerdings auch nur eine oder wenige Meldungen pro Tag.

                      nik82 1 Reply Last reply Reply Quote 0
                      • nik82
                        nik82 Most Active @klassisch last edited by

                        @klassisch
                        So schon wieder zweimal der Fehler. Also an der CCU Firmware scheint es dann nicht zu liegen.
                        Naja, dann wird nichts anderes übrig bleiben als damit zu leben 🙂

                        Trotzdem Danke für deine Info.

                        Homoran 1 Reply Last reply Reply Quote 0
                        • Homoran
                          Homoran Global Moderator Administrators @nik82 last edited by

                          @nik82 sagte in HM-Rega: invalid response und kurz ReGaHSS down / gelb:

                          So schon wieder zweimal der Fehler. Also an der CCU Firmware scheint es dann nicht zu liegen.

                          hast du mal im CCU log nachgesehen, ob da etwas drinsteht?
                          z.B. low voltage?

                          nik82 1 Reply Last reply Reply Quote 0
                          • nik82
                            nik82 Most Active @Homoran last edited by

                            @homoran
                            Jo, hab ich, hab ich auch schon im Homematic-Forum diskutiert:

                            https://homematic-forum.de/forum/viewtopic.php?f=65&t=64719&p=637123#p637123

                            Wenn ich auf "ALLES LOGGEN" stelle, dann kommen zu diesem Zeitpunkt mehrere dieser Meldungen:

                            Jan 19 14:17:34 ccu3-webui local0.info ReGaHss: Info: metadata property 'VALUE_LIST' does not exist [GetValueListProperty():iseDOMdp.cpp:425]
                            Jan 19 14:17:34 ccu3-webui local0.info ReGaHss: Info: metadata property 'MIN' does not exist [GetMinProperty():iseDOMdp.cpp:326]
                            Jan 19 14:17:34 ccu3-webui local0.info ReGaHss: Info: metadata property 'MAX' does not exist [GetMaxProperty():iseDOMdp.cpp:359]
                            

                            und mehrmals:

                            Jan 19 14:18:04 ccu3-webui local0.info ReGaHss: Info: metadata property 'VALUE_LIST' does not exist [GetValueListProperty():iseDOMdp.cpp:425]
                            
                            nik82 1 Reply Last reply Reply Quote 0
                            • nik82
                              nik82 Most Active @nik82 last edited by

                              Hallo,
                              ich wollte nur Bescheid sagen (für den ein oder anderen, der evtl. auch dieses Problem hat), der Fehler ist jetzt anscheinend nach 1,5 Jahren behoben! 🙂
                              Ich weiß leider nicht ob es an einem Iobroker Update oder am RaspberryMatic Update lag.

                              Ich habe vor vier Tagen ein Update auf die RaspberryMatic Version 3.63.9.20220625 gemacht und den Iobroker mit einer Migrationsinstallation auf JS-Controller 4.0 upgedatet und Node.js auf die Version v14.19.3 upgedatet.

                              Seit dem ist der Fehler behoben.

                              1 Reply Last reply Reply Quote 0
                              • First post
                                Last post

                              Support us

                              ioBroker
                              Community Adapters
                              Donate

                              512
                              Online

                              31.9k
                              Users

                              80.1k
                              Topics

                              1.3m
                              Posts

                              invalid response regahss down
                              3
                              28
                              962
                              Loading More Posts
                              • Oldest to Newest
                              • Newest to Oldest
                              • Most Votes
                              Reply
                              • Reply as topic
                              Log in to reply
                              Community
                              Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                              The ioBroker Community 2014-2023
                              logo