    Test Adapter HeatingControl v2.12.x

    This topic has been deleted. Only users with topic management privileges can see it.
    • M
      Michi_Pi @Rene_HM last edited by

      @rene_hm Unter WindowOpenDecrease stehten schon die 12grad
      747f4511-b6b0-4975-9655-06ed44b12861-grafik.png

      1 Reply Last reply Reply Quote 0
      • Rene_HM
        Rene_HM Developer @Samsity last edited by

        @samsity sagte in Test Adapter HeatingControl v2.1.x:

        Profil Privat 3 Urlaub anwesend
        Profil Privat 4 Urlaub abwesend

        dafür brauchst du kein Profil, das kann der Adapter selbst.

        Profil Gäste 1 nur Wochenende anwesend
        Profil Gäste 2 ganze Woche anwesend

        wenn wir eine separate Instanz haben, kannst du auch hier die Anwesenheitsfunktion des Adapters verwenden

        Profil Gäste keine Gäste anweesend

        und dafür nehmen wir die Einzelraumabschaltung, oder, wenn alle Räume der Instanz betroffen sind, die Funktion "Heizungsperiode Aktiv"

        S 1 Reply Last reply Reply Quote 0
        • Stephan Schleich
          Stephan Schleich @Rene_HM last edited by

          @rene_hm sagte in Test Adapter HeatingControl v2.1.x:

          @stephan-schleich Die Meldung kommt, weil beim Lesen auf den angegebenen Datenpunkt ein null oder gar nichts zurückkommt. Ist der DP gültig und hat er einen Wert?

          @Rene_HM Ja dort steht 23 C drinnen, den Screen hab ich dir oben mit angehängt 😉

          Rene_HM 1 Reply Last reply Reply Quote 0
          • Rene_HM
            Rene_HM Developer @Stephan Schleich last edited by

            @stephan-schleich ja, aber das log zeigt einen anderen DP als das Bild darunter... Bitte prüfe, ob in der Konfiguration für das Thermostat die richtige OID für aktuelle Temperatur steht...

            Stephan Schleich 1 Reply Last reply Reply Quote 0
            • S
              Samsity @Rene_HM last edited by

              Guten Morgen @rene_hm,

              das mit der Anwesenheitsfunktion für die Gäste muss ich mir anschauen, bin mir nicht ganz sicher wie ich das umsetzten kann.
              Ich freue mich aber auf die 2.2 mit der Einzelraumabschaltung, das könnte mir sehr helfen.

              Ich wünsche erst einmal ein schönes WE.
              Werd jetzt mal die VIS bearbeiten und testen.

              1 Reply Last reply Reply Quote 0
              • Stephan Schleich
                Stephan Schleich @Rene_HM last edited by

                @rene_hm Du hasttest Recht, beim umrechnen scheint aber nochn Fehler zu geben

                Die Raumtemperatur soll 21C haben es sind 21.9C laut externen Sensor und am Regler sind 25, wieso stellt HeatingControl dann auf 24,5 C?

                1753f47f-af1b-464b-88fc-8e15da19ae60-image.png

                Rene_HM 1 Reply Last reply Reply Quote 0
                • Rene_HM
                  Rene_HM Developer @Stephan Schleich last edited by

                  @stephan-schleich stell mal bitte auf debug und suche dann nach

                  (avg) Ist-Temperatur am Thermostat
                  

                  und poste die Zeilen davor und danach für o.g. Zimmer...
                  Generell runde ich den TempOffset auf 0,5°C...

                  Stephan Schleich 1 Reply Last reply Reply Quote 0
                  • Stephan Schleich
                    Stephan Schleich @Rene_HM last edited by Stephan Schleich

                    @rene_hm sagte in Test Adapter HeatingControl v2.1.x:

                    (avg) Ist-Temperatur am Thermostat

                    Vorhin waren die Werte schlimmer wie jetzt, da ging er auf bis zu 31C hoch ^^

                    f44455f9-9f65-48e3-9b4f-f71f06ee2915-image.png
                    0cef0c27-6d9b-4235-9ee0-c5a94a7d67ab-image.png

                    Rene_HM 1 Reply Last reply Reply Quote 0
                    • Rene_HM
                      Rene_HM Developer @Stephan Schleich last edited by Rene_HM

                      @stephan-schleich Hier mal die Kalkulation, wie es sein sollte:

                      • Ziel-Temperatur 21°C (laut Profil)
                      • Ist-Temperatur am Thermostat 25°C (warum so hoch?)
                      • Ist-Temperatur am zusätzlichen Sensor 21,92°C

                      damit wird eine aktuelle Temperaturdifferenz von

                      21.92°C - 25°C = -3,08°C
                      

                      berechnet.
                      Da ich für die Differenz den Mittelwert (gleitender Mittelwert) bilde, wird die alte Differenz (0,5°C) mit der neuen Differenz (-3,08°C) verrechnet:

                      (0,5°C -3,08°C) / 2 = -1,29 °C
                      

                      auf 0,5 gerundet ergibt das -1,5°C

                      Beim nächsten Profilwechsel wird dieser Wert dann der Profil-Solltemperatur hinzuaddiert.

                      21°C - 1,5°C = 19,5°C
                      

                      Damit sollte beim nächsten Profilwechsel (oder bei Start des Adapters) 19,5°C als Zieltemperatur auf das Thermostat geschrieben werden. Aus meiner Sicht ist damit auch das Vorzeichen (minus) für den Temperaturoffset richtig, da die Ziel-Temperatur niedriger werden muss, da am Raumsensor eine höhere Temperatur anliegt, als gewünscht.

                      Aber trotzdem ist etwas seltsam: warum schwankt der Offset bei dir so stark? Im vorliegenden Fall hattest du eine gemittelte Temperaturdifferenz von +0,5°C und beim nächsten update der Ist-Temperatur am zusätzlichen Sensor plötzlich -3,08. Eigentlich sollte sich der Temperaturoffset einschwingen und dann relativ stabil auf einem Wert bleiben.

                      Stephan Schleich 1 Reply Last reply Reply Quote 0
                      • B
                        Borio85 last edited by Borio85

                        Hallo @Rene_HM ,
                        ich habe zwei Verständnisfragen bezogen auf die zusätzlichen Temperatursensoren und würde mich freuen, wenn du mir da etwas weiterhelfen könntest, es geht um folgendes:

                        Wenn Soll-Temperatur = Ist-Temperatur ist :

                        • Obwohl die Ist-Temperatur des zusätzlichen Sensors 19.5°C ist und genau der Ziel-Temperatur des Profils entspricht, berechnet HeatingControl einen Offset von -2°C.
                          Wenn die Ziel-Temperatur = Ist-Temperatur ist braucht es doch keinen Offset oder sehe ich das falsch?
                        2021-02-07 12:07:24.786  -  [34mdebug [39m: heatingcontrol.0 (4668) check Arbeitszimmer
                        2021-02-07 12:07:24.788  -  [34mdebug [39m: heatingcontrol.0 (4668) got offset -1.5 for Arbeitszimmer
                        2021-02-07 12:07:24.836  -  [34mdebug [39m: heatingcontrol.0 (4668) calculate temp offset for Arbeitszimmer old value is -1.5, got value {"val":19.5,"ack":true,"ts":1612695360081,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612695360081}
                        2021-02-07 12:07:24.837  -  [34mdebug [39m: heatingcontrol.0 (4668) got 22.2 from hmip.0.devices.3014F711A0000A1BE99B884C.channels.1.valveActualTemperature
                        2021-02-07 12:07:24.838  -  [34mdebug [39m: heatingcontrol.0 (4668) tempdiff: 19.5 - 22.2 = -2.6999999999999993
                        2021-02-07 12:07:24.838  -  [34mdebug [39m: heatingcontrol.0 (4668) TempOffset Arbeitszimmer
                        2021-02-07 12:07:24.839  -  [34mdebug [39m: heatingcontrol.0 (4668) (avg) Ist-Temperatur am Thermostat 22.2
                        2021-02-07 12:07:24.839  -  [34mdebug [39m: heatingcontrol.0 (4668) Ist-Temperatur am zusätzl. Sensor 19.5
                        2021-02-07 12:07:24.839  -  [34mdebug [39m: heatingcontrol.0 (4668) tempDiff -2.6999999999999993
                        2021-02-07 12:07:24.839  -  [34mdebug [39m: heatingcontrol.0 (4668) (avg) TempOffset -2
                        2021-02-07 12:07:24.848  -  [34mdebug [39m: heatingcontrol.0 (4668) new temp offset for Arbeitszimmer is -2
                        

                        Wenn Ist-Temperatur < Soll-Temperatur ist:

                        • Im Flur habe ich eine Soll-Temperatur von 19.5°C, am Sensor eine Ist-Temperatur von 19,41°C und HeatingControl berechnet einen Offset von -2,5°C und setzt die Soll-Temperatur 17°C.
                          Sollte in diesem Fall nicht die Temperatur eher erhöht werden z.B. auf 20°C, damit auch die gewünschten 19,5°C erreicht werden anstatt runter zu gehen auf 17°C?
                        2021-02-07 12:07:39.161  -  [34mdebug [39m: heatingcontrol.0 (4695) check Flur
                        2021-02-07 12:07:39.163  -  [34mdebug [39m: heatingcontrol.0 (4695) got offset -2 for Flur
                        2021-02-07 12:07:39.167  -  [34mdebug [39m: heatingcontrol.0 (4695) calculate temp offset for Flur old value is -2, got value {"val":19.41,"ack":true,"ts":1612695172380,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612695172380}
                        2021-02-07 12:07:39.170  -  [34mdebug [39m: heatingcontrol.0 (4695) got 22 from hmip.0.devices.3014F711A0000A1BE99B8B33.channels.1.valveActualTemperature
                        2021-02-07 12:07:39.170  -  [34mdebug [39m: heatingcontrol.0 (4695) tempdiff: 19.41 - 22 = -2.59
                        2021-02-07 12:07:39.171  -  [34mdebug [39m: heatingcontrol.0 (4695) TempOffset Flur
                        2021-02-07 12:07:39.171  -  [34mdebug [39m: heatingcontrol.0 (4695) (avg) Ist-Temperatur am Thermostat 22
                        2021-02-07 12:07:39.172  -  [34mdebug [39m: heatingcontrol.0 (4695) Ist-Temperatur am zusätzl. Sensor 19.41
                        2021-02-07 12:07:39.172  -  [34mdebug [39m: heatingcontrol.0 (4695) tempDiff -2.59
                        2021-02-07 12:07:39.172  -  [34mdebug [39m: heatingcontrol.0 (4695) (avg) TempOffset -2.5
                        2021-02-07 12:07:39.231  -  [34mdebug [39m: heatingcontrol.0 (4695) new temp offset for Flur is -2.5
                        
                        1 Reply Last reply Reply Quote 0
                        • Stephan Schleich
                          Stephan Schleich @Rene_HM last edited by Stephan Schleich

                          @rene_hm Hmm okay ich werd's mal beobachten, die Differenz ist so groß weil es ein relativ großer raum ist.
                          einige Punkte seh ich wie @Borio85

                          Rene_HM 1 Reply Last reply Reply Quote 0
                          • Rene_HM
                            Rene_HM Developer @Stephan Schleich last edited by

                            @stephan-schleich @Borio85 zur History des features siehe
                            https://github.com/rg-engineering/ioBroker.heatingcontrol/issues/182

                            Es gibt keinen Vergleich zwischen Soll und Ist, sondern nur einen Vergleich der Ist-Werte am Thermostat und am Raumsensor.

                            Denkra created this issue in rg-engineering/ioBroker.heatingcontrol

                            closed Temperatur Offset #182

                            B 1 Reply Last reply Reply Quote 0
                            • B
                              Borio85 @Rene_HM last edited by Borio85

                              @rene_hm said in Test Adapter HeatingControl v2.1.x:

                              @stephan-schleich @Borio85 zur History des features siehe
                              https://github.com/rg-engineering/ioBroker.heatingcontrol/issues/182

                              Es gibt keinen Vergleich zwischen Soll und Ist, sondern nur einen Vergleich der Ist-Werte am Thermostat und am Raumsensor.

                              Ok, das erklärt wieso ein Offset berechnet wird obwohl ist=soll ist. Wäre ein Vergleich nicht Sinnvoll?

                              Aktuell habe ich das Problem, dass im Arbeitszimmer 19.5C sein soll aber der Adapter auf 18.5 stellt aufgrund des Offsets.

                              
                              2021-02-07 16:17:36.688  - debug: heatingcontrol.0 (16373) SetRoomTemperature started for Arbeitszimmer target 19.5 with offset -1
                              2021-02-07 16:17:36.692  - debug: heatingcontrol.0 (16373) Arbeitszimmer nothing to do to for hmip.0.devices.3014F711A0000A1BE99B884C.channels.1.setPointTemperature , target 18.5 is already set 18.5
                              2021-02-07 16:17:36.693  - debug: heatingcontrol.0 (16373) HandleActors for Arbeitszimmer auto
                              2021-02-07 16:17:36.694  - debug: heatingcontrol.0 (16373) UpdateDPs  for Arbeitszimmer auto
                              2021-02-07 16:17:36.771  - debug: heatingcontrol.0 (16373) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.CurrentTimePeriod 
                              
                              
                              Rene_HM 1 Reply Last reply Reply Quote 0
                              • Rene_HM
                                Rene_HM Developer @Borio85 last edited by

                                @borio85 schau dir bitte meinen post weiter oben an, in dem ich erkläre, was der Adapter rechnet und gib uns diese Werte. Mit diesen Informationen hier kann ich den Offset nicht erklären...

                                B 1 Reply Last reply Reply Quote 0
                                • B
                                  Borio85 @Rene_HM last edited by

                                  @rene_hm

                                  Ok, dann versuche ich das mal so gut wie ich kann zu beschreiben:

                                  Objekt-ID aktuelle Temperatur = Homematic valveActualTemperature
                                  Objekt-ID Zieltemperatur = Homematic setPointTemperature
                                  Objekt-ID zusätzlicher Sensor = Zigebee temperature

                                  Profil für das Arbeitszimmer, sollte jetzt 19.5°C sein
                                  11f3d0ad-438c-41cd-9f51-5ea49e39008d-grafik.png

                                  Temperatur am Regler 21,6°C
                                  Temperatur am Raumsensor 18,4°C
                                  Gesetzte Temperatur 14°C

                                  2021-02-07 17:45:15.171  - debug: heatingcontrol.0 (21224) Arbeitszimmer ### ChangeStatus AddTempSensor to {"val":17.4,"ack":true,"ts":1612716315167,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612716315167} in auto
                                  2021-02-07 17:45:15.172  - debug: heatingcontrol.0 (21224) calculate temp offset for Arbeitszimmer old value is -4.5, got value {"val":17.4,"ack":true,"ts":1612716315167,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612716315167}
                                  2021-02-07 17:45:15.174  - debug: heatingcontrol.0 (21224) got 23.7 from hmip.0.devices.3014F711A0000A1BE99B884C.channels.1.valveActualTemperature
                                  2021-02-07 17:45:15.175  - debug: heatingcontrol.0 (21224) tempdiff: 17.4 - 23.7 = -6.300000000000001
                                  2021-02-07 17:45:15.175  - debug: heatingcontrol.0 (21224) TempOffset Arbeitszimmer
                                  2021-02-07 17:45:15.177  - debug: heatingcontrol.0 (21224) (avg) Ist-Temperatur am Thermostat 23.7
                                  2021-02-07 17:45:15.178  - debug: heatingcontrol.0 (21224) Ist-Temperatur am zusätzl. Sensor 17.4
                                  2021-02-07 17:45:15.178  - debug: heatingcontrol.0 (21224) tempDiff -6.300000000000001
                                  2021-02-07 17:45:15.179  - debug: heatingcontrol.0 (21224) (avg) TempOffset -5.5
                                  2021-02-07 17:45:15.190  - debug: heatingcontrol.0 (21224) new temp offset for Arbeitszimmer is -5.5
                                  2021-02-07 17:45:15.191  - debug: heatingcontrol.0 (21224) UpdateDPs  for Arbeitszimmer auto
                                  
                                  2021-02-07 17:47:02.796  - debug: heatingcontrol.0 (21224) Change Status current temperature in Arbeitszimmer to 21.9
                                  2021-02-07 17:47:02.796  - debug: heatingcontrol.0 (21224) HandleActors for Arbeitszimmer auto
                                  2021-02-07 17:47:02.796  - debug: heatingcontrol.0 (21224) UpdateDPs  for Arbeitszimmer auto
                                  2021-02-07 17:47:02.811  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.CurrentTimePeriod {"val":9,"ack":false,"ts":1612716422809,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716008312}
                                  2021-02-07 17:47:02.812  - debug: heatingcontrol.0 (21224) HandleStateChanges CurrentTimePeriod 9
                                  2021-02-07 17:47:02.818  - debug: heatingcontrol.0 (21224) AddStatusToLog skip Arbeitszimmer auto WindowOpen 12.5°C
                                  2021-02-07 17:47:02.873  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.StatusLog {"val":" 07.02.2021 17:42:00 auto WindowOpen 12.5°C <br> 07.02.2021 17:40:08 auto 18.5°C <br> 07.02.2021 17:40:04 starting 19.5°C <br> 07.02.2021 17:40:03 starting <br>","ack":false,"ts":1612716422870,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716120447}
                                  2021-02-07 17:47:02.873  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  2021-02-07 17:47:16.306  - debug: heatingcontrol.0 (21224) Arbeitszimmer ### ChangeStatus AddTempSensor to {"val":16.4,"ack":true,"ts":1612716436298,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612716436298} in auto
                                  2021-02-07 17:47:16.306  - debug: heatingcontrol.0 (21224) calculate temp offset for Arbeitszimmer old value is -5.5, got value {"val":16.4,"ack":true,"ts":1612716436298,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612716436298}
                                  2021-02-07 17:47:16.308  - debug: heatingcontrol.0 (21224) got 21.9 from hmip.0.devices.3014F711A0000A1BE99B884C.channels.1.valveActualTemperature
                                  2021-02-07 17:47:16.309  - debug: heatingcontrol.0 (21224) tempdiff: 16.4 - 21.9 = -5.5
                                  2021-02-07 17:47:16.309  - debug: heatingcontrol.0 (21224) TempOffset Arbeitszimmer
                                  2021-02-07 17:47:16.310  - debug: heatingcontrol.0 (21224) (avg) Ist-Temperatur am Thermostat 21.9
                                  2021-02-07 17:47:16.310  - debug: heatingcontrol.0 (21224) Ist-Temperatur am zusätzl. Sensor 16.4
                                  2021-02-07 17:47:16.311  - debug: heatingcontrol.0 (21224) tempDiff -5.5
                                  2021-02-07 17:47:16.311  - debug: heatingcontrol.0 (21224) (avg) TempOffset -5.5
                                  2021-02-07 17:47:16.319  - debug: heatingcontrol.0 (21224) new temp offset for Arbeitszimmer is -5.5
                                  2021-02-07 17:47:16.320  - debug: heatingcontrol.0 (21224) UpdateDPs  for Arbeitszimmer auto
                                  2021-02-07 17:47:16.345  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.CurrentTimePeriod {"val":9,"ack":false,"ts":1612716436341,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716008312}
                                  2021-02-07 17:47:16.346  - debug: heatingcontrol.0 (21224) HandleStateChanges CurrentTimePeriod 9
                                  2021-02-07 17:47:16.359  - debug: heatingcontrol.0 (21224) AddStatusToLog skip Arbeitszimmer auto WindowOpen 12.5°C
                                  2021-02-07 17:47:16.425  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.StatusLog {"val":" 07.02.2021 17:42:00 auto WindowOpen 12.5°C <br> 07.02.2021 17:40:08 auto 18.5°C <br> 07.02.2021 17:40:04 starting 19.5°C <br> 07.02.2021 17:40:03 starting <br>","ack":false,"ts":1612716436422,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716120447}
                                  2021-02-07 17:47:16.426  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  2021-02-07 17:47:33.432  - debug: heatingcontrol.0 (21224) Badezimmer ### ChangeStatus AddTempSensor to {"val":20.9,"ack":true,"ts":1612716453426,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612716453426} in auto
                                  
                                  2021-02-07 17:48:06.269  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  2021-02-07 17:48:16.877  - debug: heatingcontrol.0 (21224) Arbeitszimmer ### ChangeStatus AddTempSensor to {"val":15.8,"ack":true,"ts":1612716496874,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612716496874} in auto
                                  2021-02-07 17:48:16.878  - debug: heatingcontrol.0 (21224) calculate temp offset for Arbeitszimmer old value is -5.5, got value {"val":15.8,"ack":true,"ts":1612716496874,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612716496874}
                                  2021-02-07 17:48:16.879  - debug: heatingcontrol.0 (21224) got 21.9 from hmip.0.devices.3014F711A0000A1BE99B884C.channels.1.valveActualTemperature
                                  2021-02-07 17:48:16.880  - debug: heatingcontrol.0 (21224) tempdiff: 15.8 - 21.9 = -6.099999999999998
                                  2021-02-07 17:48:16.880  - debug: heatingcontrol.0 (21224) TempOffset Arbeitszimmer
                                  2021-02-07 17:48:16.881  - debug: heatingcontrol.0 (21224) (avg) Ist-Temperatur am Thermostat 21.9
                                  2021-02-07 17:48:16.881  - debug: heatingcontrol.0 (21224) Ist-Temperatur am zusätzl. Sensor 15.8
                                  2021-02-07 17:48:16.881  - debug: heatingcontrol.0 (21224) tempDiff -6.099999999999998
                                  2021-02-07 17:48:16.882  - debug: heatingcontrol.0 (21224) (avg) TempOffset -6
                                  2021-02-07 17:48:16.888  - debug: heatingcontrol.0 (21224) new temp offset for Arbeitszimmer is -6
                                  2021-02-07 17:48:16.889  - debug: heatingcontrol.0 (21224) UpdateDPs  for Arbeitszimmer auto
                                  2021-02-07 17:48:16.907  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.CurrentTimePeriod {"val":9,"ack":false,"ts":1612716496904,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716008312}
                                  2021-02-07 17:48:16.908  - debug: heatingcontrol.0 (21224) HandleStateChanges CurrentTimePeriod 9
                                  2021-02-07 17:48:16.917  - debug: heatingcontrol.0 (21224) AddStatusToLog skip Arbeitszimmer auto 14°C
                                  2021-02-07 17:48:16.975  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.StatusLog {"val":" 07.02.2021 17:47:48 auto 14°C <br> 07.02.2021 17:42:00 auto WindowOpen 12.5°C <br> 07.02.2021 17:40:08 auto 18.5°C <br> 07.02.2021 17:40:04 starting 19.5°C <br> 07.02.2021 17:40:03 starting <br>","ack":false,"ts":1612716496972,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716468524}
                                  2021-02-07 17:48:16.976  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  2021-02-07 17:48:25.288  - debug: heatingcontrol.0 (21224) Arbeitszimmer ### ChangeStatus Thermostats_Target to {"val":14,"ack":true,"ts":1612716505217,"q":0,"from":"system.adapter.hmip.0","user":"system.user.admin","lc":1612716468439} in auto
                                  2021-02-07 17:48:25.289  - debug: heatingcontrol.0 (21224) Change Status target temperature in Arbeitszimmer to 14 (profile 19.5) in auto
                                  2021-02-07 17:48:25.290  - debug: heatingcontrol.0 (21224) CheckManualMode Arbeitszimmer
                                  2021-02-07 17:48:25.290  - debug: heatingcontrol.0 (21224) CheckStartManualMode Arbeitszimmer
                                  2021-02-07 17:48:25.291  - debug: heatingcontrol.0 (21224) UpdateDPs  for Arbeitszimmer auto
                                  2021-02-07 17:48:25.294  - debug: heatingcontrol.0 (21224) ChangeStatus called, while already changing, push to list Arbeitszimmer Thermostats_Current {"val":21.4,"ack":true,"ts":1612716505218,"q":0,"from":"system.adapter.hmip.0","user":"system.user.admin","lc":1612716505218} (1)
                                  2021-02-07 17:48:25.331  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.CurrentTimePeriod {"val":9,"ack":false,"ts":1612716505328,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716008312}
                                  2021-02-07 17:48:25.331  - debug: heatingcontrol.0 (21224) HandleStateChanges CurrentTimePeriod 9
                                  2021-02-07 17:48:25.338  - debug: heatingcontrol.0 (21224) AddStatusToLog skip Arbeitszimmer auto 14°C
                                  2021-02-07 17:48:25.406  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.StatusLog {"val":" 07.02.2021 17:47:48 auto 14°C <br> 07.02.2021 17:42:00 auto WindowOpen 12.5°C <br> 07.02.2021 17:40:08 auto 18.5°C <br> 07.02.2021 17:40:04 starting 19.5°C <br> 07.02.2021 17:40:03 starting <br>","ack":false,"ts":1612716505404,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716468524}
                                  2021-02-07 17:48:25.407  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  2021-02-07 17:48:25.414  - debug: heatingcontrol.0 (21224) ChangeStatus recall cmd from list Arbeitszimmer Thermostats_Current {"val":21.4,"ack":true,"ts":1612716505218,"q":0,"from":"system.adapter.hmip.0","user":"system.user.admin","lc":1612716505218} (0)
                                  2021-02-07 17:48:25.414  - debug: heatingcontrol.0 (21224) Arbeitszimmer ### ChangeStatus Thermostats_Current to {"val":21.4,"ack":true,"ts":1612716505218,"q":0,"from":"system.adapter.hmip.0","user":"system.user.admin","lc":1612716505218} in auto
                                  2021-02-07 17:48:25.414  - debug: heatingcontrol.0 (21224) Change Status current temperature in Arbeitszimmer to 21.4
                                  2021-02-07 17:48:25.415  - debug: heatingcontrol.0 (21224) HandleActors for Arbeitszimmer auto
                                  2021-02-07 17:48:25.415  - debug: heatingcontrol.0 (21224) UpdateDPs  for Arbeitszimmer auto
                                  2021-02-07 17:48:25.430  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.CurrentTimePeriod {"val":9,"ack":false,"ts":1612716505427,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716008312}
                                  2021-02-07 17:48:25.430  - debug: heatingcontrol.0 (21224) HandleStateChanges CurrentTimePeriod 9
                                  2021-02-07 17:48:25.436  - debug: heatingcontrol.0 (21224) AddStatusToLog skip Arbeitszimmer auto 14°C
                                  2021-02-07 17:48:25.448  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.StatusLog {"val":" 07.02.2021 17:47:48 auto 14°C <br> 07.02.2021 17:42:00 auto WindowOpen 12.5°C <br> 07.02.2021 17:40:08 auto 18.5°C <br> 07.02.2021 17:40:04 starting 19.5°C <br> 07.02.2021 17:40:03 starting <br>","ack":false,"ts":1612716505445,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716468524}
                                  2021-02-07 17:48:25.448  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  2021-02-07 17:48:32.858  - debug: heatingcontrol.0 (21224) Wohnzimmer ### ChangeStatus AddTempSensor to {"val":21.4,"ack":true,"ts":1612716512795,"q":0,"from":"system.adapter.hmip.0","user":"system.user.admin","lc":1612710917340} in auto
                                  
                                  2021-02-07 17:49:14.629  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  2021-02-07 17:49:17.462  - debug: heatingcontrol.0 (21224) Arbeitszimmer ### ChangeStatus AddTempSensor to {"val":16.1,"ack":true,"ts":1612716557457,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612716557457} in auto
                                  2021-02-07 17:49:17.463  - debug: heatingcontrol.0 (21224) calculate temp offset for Arbeitszimmer old value is -6, got value {"val":16.1,"ack":true,"ts":1612716557457,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612716557457}
                                  2021-02-07 17:49:17.465  - debug: heatingcontrol.0 (21224) got 21.4 from hmip.0.devices.3014F711A0000A1BE99B884C.channels.1.valveActualTemperature
                                  2021-02-07 17:49:17.465  - debug: heatingcontrol.0 (21224) tempdiff: 16.1 - 21.4 = -5.299999999999997
                                  2021-02-07 17:49:17.466  - debug: heatingcontrol.0 (21224) TempOffset Arbeitszimmer
                                  2021-02-07 17:49:17.466  - debug: heatingcontrol.0 (21224) (avg) Ist-Temperatur am Thermostat 21.4
                                  2021-02-07 17:49:17.467  - debug: heatingcontrol.0 (21224) Ist-Temperatur am zusätzl. Sensor 16.1
                                  2021-02-07 17:49:17.467  - debug: heatingcontrol.0 (21224) tempDiff -5.299999999999997
                                  2021-02-07 17:49:17.468  - debug: heatingcontrol.0 (21224) (avg) TempOffset -5.5
                                  2021-02-07 17:49:17.476  - debug: heatingcontrol.0 (21224) new temp offset for Arbeitszimmer is -5.5
                                  2021-02-07 17:49:17.477  - debug: heatingcontrol.0 (21224) UpdateDPs  for Arbeitszimmer auto
                                  2021-02-07 17:49:17.505  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.CurrentTimePeriod {"val":9,"ack":false,"ts":1612716557499,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716008312}
                                  2021-02-07 17:49:17.506  - debug: heatingcontrol.0 (21224) HandleStateChanges CurrentTimePeriod 9
                                  2021-02-07 17:49:17.520  - debug: heatingcontrol.0 (21224) AddStatusToLog skip Arbeitszimmer auto 14°C
                                  2021-02-07 17:49:17.585  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.StatusLog {"val":" 07.02.2021 17:47:48 auto 14°C <br> 07.02.2021 17:42:00 auto WindowOpen 12.5°C <br> 07.02.2021 17:40:08 auto 18.5°C <br> 07.02.2021 17:40:04 starting 19.5°C <br> 07.02.2021 17:40:03 starting <br>","ack":false,"ts":1612716557582,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716468524}
                                  2021-02-07 17:49:17.586  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  2021-02-07 17:49:36.673  - debug: heatingcontrol.0 (21224) Küche ### ChangeStatus Thermostats_Target to {"val":18.5,"ack":true,"ts":1612716576619,"q":0,"from":"system.adapter.hmip.0","user":"system.user.admin","lc":1612716009234} in auto
                                  
                                  2021-02-07 17:50:07.052  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  2021-02-07 17:50:18.039  - debug: heatingcontrol.0 (21224) Arbeitszimmer ### ChangeStatus AddTempSensor to {"val":16.3,"ack":true,"ts":1612716618031,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612716618031} in auto
                                  2021-02-07 17:50:18.040  - debug: heatingcontrol.0 (21224) calculate temp offset for Arbeitszimmer old value is -5.5, got value {"val":16.3,"ack":true,"ts":1612716618031,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612716618031}
                                  2021-02-07 17:50:18.042  - debug: heatingcontrol.0 (21224) got 21.4 from hmip.0.devices.3014F711A0000A1BE99B884C.channels.1.valveActualTemperature
                                  2021-02-07 17:50:18.042  - debug: heatingcontrol.0 (21224) tempdiff: 16.3 - 21.4 = -5.099999999999998
                                  2021-02-07 17:50:18.043  - debug: heatingcontrol.0 (21224) TempOffset Arbeitszimmer
                                  2021-02-07 17:50:18.043  - debug: heatingcontrol.0 (21224) (avg) Ist-Temperatur am Thermostat 21.4
                                  2021-02-07 17:50:18.044  - debug: heatingcontrol.0 (21224) Ist-Temperatur am zusätzl. Sensor 16.3
                                  2021-02-07 17:50:18.044  - debug: heatingcontrol.0 (21224) tempDiff -5.099999999999998
                                  2021-02-07 17:50:18.044  - debug: heatingcontrol.0 (21224) (avg) TempOffset -5.5
                                  2021-02-07 17:50:18.052  - debug: heatingcontrol.0 (21224) new temp offset for Arbeitszimmer is -5.5
                                  2021-02-07 17:50:18.053  - debug: heatingcontrol.0 (21224) UpdateDPs  for Arbeitszimmer auto
                                  2021-02-07 17:50:18.073  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.CurrentTimePeriod {"val":9,"ack":false,"ts":1612716618069,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716008312}
                                  2021-02-07 17:50:18.074  - debug: heatingcontrol.0 (21224) HandleStateChanges CurrentTimePeriod 9
                                  2021-02-07 17:50:18.085  - debug: heatingcontrol.0 (21224) AddStatusToLog skip Arbeitszimmer auto 14°C
                                  2021-02-07 17:50:18.140  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.StatusLog {"val":" 07.02.2021 17:47:48 auto 14°C <br> 07.02.2021 17:42:00 auto WindowOpen 12.5°C <br> 07.02.2021 17:40:08 auto 18.5°C <br> 07.02.2021 17:40:04 starting 19.5°C <br> 07.02.2021 17:40:03 starting <br>","ack":false,"ts":1612716618136,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716468524}
                                  2021-02-07 17:50:18.141  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  
                                  2021-02-07 17:54:06.579  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  2021-02-07 17:54:20.331  - debug: heatingcontrol.0 (21224) Arbeitszimmer ### ChangeStatus AddTempSensor to {"val":17,"ack":true,"ts":1612716860324,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612716860324} in auto
                                  2021-02-07 17:54:20.332  - debug: heatingcontrol.0 (21224) calculate temp offset for Arbeitszimmer old value is -5.5, got value {"val":17,"ack":true,"ts":1612716860324,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612716860324}
                                  2021-02-07 17:54:20.334  - debug: heatingcontrol.0 (21224) got 20.6 from hmip.0.devices.3014F711A0000A1BE99B884C.channels.1.valveActualTemperature
                                  2021-02-07 17:54:20.335  - debug: heatingcontrol.0 (21224) tempdiff: 17 - 20.6 = -3.6000000000000014
                                  2021-02-07 17:54:20.335  - debug: heatingcontrol.0 (21224) TempOffset Arbeitszimmer
                                  2021-02-07 17:54:20.336  - debug: heatingcontrol.0 (21224) (avg) Ist-Temperatur am Thermostat 20.6
                                  2021-02-07 17:54:20.336  - debug: heatingcontrol.0 (21224) Ist-Temperatur am zusätzl. Sensor 17
                                  2021-02-07 17:54:20.337  - debug: heatingcontrol.0 (21224) tempDiff -3.6000000000000014
                                  2021-02-07 17:54:20.345  - debug: heatingcontrol.0 (21224) (avg) TempOffset -4.5
                                  2021-02-07 17:54:20.355  - debug: heatingcontrol.0 (21224) new temp offset for Arbeitszimmer is -4.5
                                  2021-02-07 17:54:20.356  - debug: heatingcontrol.0 (21224) UpdateDPs  for Arbeitszimmer auto
                                  2021-02-07 17:54:20.384  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.CurrentTimePeriod {"val":9,"ack":false,"ts":1612716860379,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716008312}
                                  2021-02-07 17:54:20.385  - debug: heatingcontrol.0 (21224) HandleStateChanges CurrentTimePeriod 9
                                  2021-02-07 17:54:20.395  - debug: heatingcontrol.0 (21224) AddStatusToLog skip Arbeitszimmer auto 14°C
                                  2021-02-07 17:54:20.454  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.StatusLog {"val":" 07.02.2021 17:47:48 auto 14°C <br> 07.02.2021 17:42:00 auto WindowOpen 12.5°C <br> 07.02.2021 17:40:08 auto 18.5°C <br> 07.02.2021 17:40:04 starting 19.5°C <br> 07.02.2021 17:40:03 starting <br>","ack":false,"ts":1612716860452,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716468524}
                                  2021-02-07 17:54:20.455  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  
                                  2021-02-07 18:00:16.803  - debug: heatingcontrol.0 (21224) Arbeitszimmer ### ChangeStatus Thermostats_Target to {"val":14,"ack":true,"ts":1612717216737,"q":0,"from":"system.adapter.hmip.0","user":"system.user.admin","lc":1612716468439} in auto
                                  2021-02-07 18:00:16.803  - debug: heatingcontrol.0 (21224) Change Status target temperature in Arbeitszimmer to 14 (profile 19.5) in auto
                                  2021-02-07 18:00:16.804  - debug: heatingcontrol.0 (21224) CheckManualMode Arbeitszimmer
                                  2021-02-07 18:00:16.804  - debug: heatingcontrol.0 (21224) CheckStartManualMode Arbeitszimmer
                                  2021-02-07 18:00:16.805  - debug: heatingcontrol.0 (21224) UpdateDPs  for Arbeitszimmer auto
                                  2021-02-07 18:00:16.807  - debug: heatingcontrol.0 (21224) ChangeStatus called, while already changing, push to list Arbeitszimmer Thermostats_Current {"val":20.9,"ack":true,"ts":1612717216737,"q":0,"from":"system.adapter.hmip.0","user":"system.user.admin","lc":1612717216737} (1)
                                  2021-02-07 18:00:16.877  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.CurrentTimePeriod {"val":9,"ack":false,"ts":1612717216875,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716008312}
                                  2021-02-07 18:00:16.877  - debug: heatingcontrol.0 (21224) HandleStateChanges CurrentTimePeriod 9
                                  2021-02-07 18:00:16.883  - debug: heatingcontrol.0 (21224) AddStatusToLog skip Arbeitszimmer auto 14°C
                                  2021-02-07 18:00:16.932  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.StatusLog {"val":" 07.02.2021 17:47:48 auto 14°C <br> 07.02.2021 17:42:00 auto WindowOpen 12.5°C <br> 07.02.2021 17:40:08 auto 18.5°C <br> 07.02.2021 17:40:04 starting 19.5°C <br> 07.02.2021 17:40:03 starting <br>","ack":false,"ts":1612717216930,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716468524}
                                  2021-02-07 18:00:16.933  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  2021-02-07 18:00:16.938  - debug: heatingcontrol.0 (21224) ChangeStatus recall cmd from list Arbeitszimmer Thermostats_Current {"val":20.9,"ack":true,"ts":1612717216737,"q":0,"from":"system.adapter.hmip.0","user":"system.user.admin","lc":1612717216737} (0)
                                  2021-02-07 18:00:16.939  - debug: heatingcontrol.0 (21224) Arbeitszimmer ### ChangeStatus Thermostats_Current to {"val":20.9,"ack":true,"ts":1612717216737,"q":0,"from":"system.adapter.hmip.0","user":"system.user.admin","lc":1612717216737} in auto
                                  2021-02-07 18:00:16.939  - debug: heatingcontrol.0 (21224) Change Status current temperature in Arbeitszimmer to 20.9
                                  2021-02-07 18:00:16.939  - debug: heatingcontrol.0 (21224) HandleActors for Arbeitszimmer auto
                                  2021-02-07 18:00:16.940  - debug: heatingcontrol.0 (21224) UpdateDPs  for Arbeitszimmer auto
                                  2021-02-07 18:00:16.953  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.CurrentTimePeriod {"val":9,"ack":false,"ts":1612717216951,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716008312}
                                  2021-02-07 18:00:16.954  - debug: heatingcontrol.0 (21224) HandleStateChanges CurrentTimePeriod 9
                                  2021-02-07 18:00:16.960  - debug: heatingcontrol.0 (21224) AddStatusToLog skip Arbeitszimmer auto 14°C
                                  2021-02-07 18:00:17.012  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.StatusLog {"val":" 07.02.2021 17:47:48 auto 14°C <br> 07.02.2021 17:42:00 auto WindowOpen 12.5°C <br> 07.02.2021 17:40:08 auto 18.5°C <br> 07.02.2021 17:40:04 starting 19.5°C <br> 07.02.2021 17:40:03 starting <br>","ack":false,"ts":1612717217010,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716468524}
                                  2021-02-07 18:00:17.013  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  2021-02-07 18:00:23.749  - debug: heatingcontrol.0 (21224) Arbeitszimmer ### ChangeStatus AddTempSensor to {"val":17.7,"ack":true,"ts":1612717223747,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612717223747} in auto
                                  2021-02-07 18:00:23.750  - debug: heatingcontrol.0 (21224) calculate temp offset for Arbeitszimmer old value is -4.5, got value {"val":17.7,"ack":true,"ts":1612717223747,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612717223747}
                                  2021-02-07 18:00:23.751  - debug: heatingcontrol.0 (21224) got 20.9 from hmip.0.devices.3014F711A0000A1BE99B884C.channels.1.valveActualTemperature
                                  2021-02-07 18:00:23.752  - debug: heatingcontrol.0 (21224) tempdiff: 17.7 - 20.9 = -3.1999999999999993
                                  2021-02-07 18:00:23.752  - debug: heatingcontrol.0 (21224) TempOffset Arbeitszimmer
                                  2021-02-07 18:00:23.752  - debug: heatingcontrol.0 (21224) (avg) Ist-Temperatur am Thermostat 20.9
                                  2021-02-07 18:00:23.753  - debug: heatingcontrol.0 (21224) Ist-Temperatur am zusätzl. Sensor 17.7
                                  2021-02-07 18:00:23.753  - debug: heatingcontrol.0 (21224) tempDiff -3.1999999999999993
                                  2021-02-07 18:00:23.753  - debug: heatingcontrol.0 (21224) (avg) TempOffset -4
                                  2021-02-07 18:00:23.770  - debug: heatingcontrol.0 (21224) new temp offset for Arbeitszimmer is -4
                                  2021-02-07 18:00:23.770  - debug: heatingcontrol.0 (21224) UpdateDPs  for Arbeitszimmer auto
                                  2021-02-07 18:00:23.783  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.CurrentTimePeriod {"val":9,"ack":false,"ts":1612717223781,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716008312}
                                  2021-02-07 18:00:23.784  - debug: heatingcontrol.0 (21224) HandleStateChanges CurrentTimePeriod 9
                                  2021-02-07 18:00:23.790  - debug: heatingcontrol.0 (21224) AddStatusToLog skip Arbeitszimmer auto 14°C
                                  2021-02-07 18:00:23.844  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.StatusLog {"val":" 07.02.2021 17:47:48 auto 14°C <br> 07.02.2021 17:42:00 auto WindowOpen 12.5°C <br> 07.02.2021 17:40:08 auto 18.5°C <br> 07.02.2021 17:40:04 starting 19.5°C <br> 07.02.2021 17:40:03 starting <br>","ack":false,"ts":1612717223842,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716468524}
                                  2021-02-07 18:00:23.845  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  
                                  2021-02-07 18:11:04.996  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  2021-02-07 18:11:30.036  - debug: heatingcontrol.0 (21224) Arbeitszimmer ### ChangeStatus AddTempSensor to {"val":18.4,"ack":true,"ts":1612717890030,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612717890030} in auto
                                  2021-02-07 18:11:30.037  - debug: heatingcontrol.0 (21224) calculate temp offset for Arbeitszimmer old value is -4, got value {"val":18.4,"ack":true,"ts":1612717890030,"q":0,"from":"system.adapter.zigbee.0","user":"system.user.admin","lc":1612717890030}
                                  2021-02-07 18:11:30.038  - debug: heatingcontrol.0 (21224) got 21.3 from hmip.0.devices.3014F711A0000A1BE99B884C.channels.1.valveActualTemperature
                                  2021-02-07 18:11:30.039  - debug: heatingcontrol.0 (21224) tempdiff: 18.4 - 21.3 = -2.900000000000002
                                  2021-02-07 18:11:30.039  - debug: heatingcontrol.0 (21224) TempOffset Arbeitszimmer
                                  2021-02-07 18:11:30.039  - debug: heatingcontrol.0 (21224) (avg) Ist-Temperatur am Thermostat 21.3
                                  2021-02-07 18:11:30.040  - debug: heatingcontrol.0 (21224) Ist-Temperatur am zusätzl. Sensor 18.4
                                  2021-02-07 18:11:30.040  - debug: heatingcontrol.0 (21224) tempDiff -2.900000000000002
                                  2021-02-07 18:11:30.040  - debug: heatingcontrol.0 (21224) (avg) TempOffset -3.5
                                  2021-02-07 18:11:30.046  - debug: heatingcontrol.0 (21224) new temp offset for Arbeitszimmer is -3.5
                                  2021-02-07 18:11:30.047  - debug: heatingcontrol.0 (21224) UpdateDPs  for Arbeitszimmer auto
                                  2021-02-07 18:11:30.066  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.CurrentTimePeriod {"val":9,"ack":false,"ts":1612717890062,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716008312}
                                  2021-02-07 18:11:30.066  - debug: heatingcontrol.0 (21224) HandleStateChanges CurrentTimePeriod 9
                                  2021-02-07 18:11:30.076  - debug: heatingcontrol.0 (21224) AddStatusToLog skip Arbeitszimmer auto 14°C
                                  2021-02-07 18:11:30.135  - debug: heatingcontrol.0 (21224) ### handle state change heatingcontrol.0.Rooms.Arbeitszimmer.StatusLog {"val":" 07.02.2021 17:47:48 auto 14°C <br> 07.02.2021 17:42:00 auto WindowOpen 12.5°C <br> 07.02.2021 17:40:08 auto 18.5°C <br> 07.02.2021 17:40:04 starting 19.5°C <br> 07.02.2021 17:40:03 starting <br>","ack":false,"ts":1612717890132,"q":0,"from":"system.adapter.heatingcontrol.0","user":"system.user.admin","lc":1612716468524}
                                  2021-02-07 18:11:30.136  - debug: heatingcontrol.0 (21224) Reaching SetStatusLog for Rooms.Arbeitszimmer.StatusLog
                                  

                                  Das habe ich in den Logs gefunden zwischen 17:45 und 18:15, ich hoffe da ist alles drin was du brauchst.

                                  Rene_HM 1 Reply Last reply Reply Quote 0
                                  • B
                                    Borio85 last edited by Borio85

                                    @Rene was anders ich habe gerade gelüftet und jetzt steht das Thermostat auf 5°C
                                    Irgendwie erkennt der Adapter einen manuellen Eingriff
                                    2282e6fd-ca8b-41c6-9a3a-e1748570e861-grafik.png

                                    Hier die Logs von 18:29-18:40
                                    Log _1829-1845.txt

                                    Rene_HM 1 Reply Last reply Reply Quote 0
                                    • Rene_HM
                                      Rene_HM Developer @Borio85 last edited by

                                      @borio85 reagiert dein Thermostat auf den Fenstersensor? siehe
                                      https://github.com/rg-engineering/ioBroker.heatingcontrol/issues/217
                                      und
                                      https://github.com/rg-engineering/ioBroker.heatingcontrol/issues/202

                                      Chuckwallas created this issue in rg-engineering/ioBroker.heatingcontrol

                                      closed Fenster offen und der manuelle Modus #217

                                      Pittini created this issue in rg-engineering/ioBroker.heatingcontrol

                                      closed Strange behavior at Window open #202

                                      B 1 Reply Last reply Reply Quote 0
                                      • Rene_HM
                                        Rene_HM Developer @Borio85 last edited by

                                        @borio85 sagte in Test Adapter HeatingControl v2.1.x:

                                        Temperatur am Regler 21,6°C
                                        Temperatur am Raumsensor 18,4°C
                                        Gesetzte Temperatur 14°C

                                        Hier würde ich (wieder einmal) auf ein falsches Vorzeichen des TempOffsets tippen. Berechnet werden -5,5°C. Das Problem ist, dass ich hier irgendetwas übersehe oder von den usern falsch interpretiere. Ich habe das Vorzeichen schon zweimal gedreht, aber jedesmal erhalte ich ein log, wo es wieder nicht passt. Hier ist ziemlich klar, dass das Vorzeichen falsch ist...

                                        Was mir aber seltsam vorkommt, ist dass die Temperatur so sehr schwankt. In den logs haben wir von 18,4°C bis 15,8°C am zusätzlichen Sensor. und das innerhalb einer halben Stunde..
                                        Die Ist-Temperatur am Thermostat ist auch zwischen 23.7°C und 20,6°C. Auf der anderen Seite passt das aber zu dem TempOffset (ca. 5°C), d.h. im Raum ist es ca. 5°C kälter als am Thermostat, so dass die Zieltemperatur 5°C höher sein sollte...

                                        Ich baue morgen mal ein 2.1.1 wo ich das Vorzeichen nochmal umkehre. Dann schauen wir noch einmal...

                                        1 Reply Last reply Reply Quote 0
                                        • B
                                          Borio85 @Rene_HM last edited by Borio85

                                          @rene_hm said in Test Adapter HeatingControl v2.1.x:

                                          reagiert dein Thermostat auf den Fenstersensor? siehe
                                          https://github.com/rg-engineering/ioBroker.heatingcontrol/issues/217
                                          und
                                          https://github.com/rg-engineering/ioBroker.heatingcontrol/issues/202

                                          Nein, ich verwende absichtlich die Funktion von Homematic nicht, da ich im Arbeitszimmer Zigbee nutze und mit der Funktion Thermostat behandelt "Fenster ist offen" wurde zwar erkannt das das Fenster auf ist aber die Temperatur wurde nicht gesenkt. Um das zu umgehen habe die die Homematic Sensoren nur für Alarm konfiguriert und senke die Temperatur über den Adapter, es Funktionierte bis vorhin eigentlich sehr gut.

                                          @rene_hm said in Test Adapter HeatingControl v2.1.x:

                                          Was mir aber seltsam vorkommt, ist dass die Temperatur so sehr schwankt. In den logs haben wir von 18,4°C bis 15,8°C am zusätzlichen Sensor. und das innerhalb einer halben Stunde..

                                          Sehr wahrscheinlich hat meine Frau das Fenster aufgemacht, das Arbeitszimmer wird zur Zeit auch als Sportzimmer missbraucht 🙂

                                          @rene_hm said in Test Adapter HeatingControl v2.1.x:

                                          Ich baue morgen mal ein 2.1.1 wo ich das Vorzeichen nochmal umkehre. Dann schauen wir noch einmal...

                                          Ok, dann warte ich mal die nächste Version ab.

                                          Rene_HM 1 Reply Last reply Reply Quote 0
                                          • Rene_HM
                                            Rene_HM Developer @Borio85 last edited by

                                            @borio85 sagte in Test Adapter HeatingControl v2.1.x:

                                            Nein, ich verwende absichtlich die Funktion von Homematic nicht, da ich im Arbeitszimmer Zigbee nutze und mit der Funktion Thermostat behandelt "Fenster ist offen" wurde zwar erkannt das das Fenster auf ist aber die Temperatur wurde nicht gesenkt. Um das zu umgehen habe die die Homematic Sensoren nur für Alarm konfiguriert und senke die Temperatur über den Adapter, es Funktionierte bis vorhin eigentlich sehr gut.

                                            Laut log ist da etwas seltsam... Man sieht auch in deinem screen shot, dass nachdem das Fenster geschlossen wurde, eine Zieltemperatur von 16°C geschrieben wird. 3 Minuten später kommt vom Thermostat aber eine Zieltemperatur von 15°C zurück. Das führt dann zum manual Mode. Im manual Mode wird dann wieder 3,5°C TemperaturOffset abgezogen, das führt dann zu 11°C und so weiter.
                                            Ich werde in der 2.1.1 den Offset im manual nicht mehr verwenden. Woher aber die 15°C kommen, die urspünglich zum manual geführt haben, kann ich nicht erklären...

                                            Die 2.1.1 ist im github verfügbar

                                            B 2 Replies Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            759
                                            Online

                                            31.6k
                                            Users

                                            79.4k
                                            Topics

                                            1.3m
                                            Posts

                                            heating
                                            236
                                            3157
                                            1433222
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo