    • Hasont
      Hasont @Rene_HM last edited by

      @rene_hm
      Datenpunkte.JPG
      Meinst du so oder was aus der Konsole?

      Rene_HM 2 Replies Last reply Reply Quote 0
      • Rene_HM
        Rene_HM Developer @Hasont last edited by

        @hasont so sollte es passen...

        1 Reply Last reply Reply Quote 0
        • Rene_HM
          Rene_HM Developer @Hasont last edited by

          @hasont hast du noch mehr solche ...mirror-Werte?
          Das Problem ist ziemlich eindeutig. Ich habe eine Schleife, die von oben nach unten durch die Datenpunkte geht und die Namen vergleicht. In deinem Fall kommt tempmirror als letztes und deshalb wird der Wert von dort genommen. Ich habe nun folgende Möglichkeiten:

          • ich ignoriere die ...mirror - Werte bei der Prüfung für die history. Das mache ich im übrigen für die "sensor"-Werte auch schon.
          • ich breche die Suche nach history-Werten ab, sobald ich den ersten gefunden habe. Das würde im vorliegenden Fall helfen, wenn es aber andere Werte gibt, wo der mirror-Wert in der Liste vor dem eigentlichen Wert auftaucht, habe ich wieder das gleiche Problem
          • ich baue das ganze um, und gebe ganze Datenpunkte für die history ein (anstelle der Namen). Das ist dann nicht mehr abwärtskompatibel zur bisherigen Version und jeder Nutzer muss die history-Werte neu konfigurieren. Außerdem ist das der größte Aufwand (aber wahrscheinlich die beste Lösung)
          Hasont 1 Reply Last reply Reply Quote 1
          • Hasont
            Hasont @Rene_HM last edited by

            @rene_hm
            ich hab bei mir so weiter keine mirror Werte.
            Kann mich auch nicht erinnern sowas schon mal gesehen zu haben.

            Das einzige wo er auch mehrere Werte mit ; getrennt ausgibt wäre z.B. Status01 der ja auch von dir mit abgefragt wird
            und da kommen auch mehrere Daten zurück.

            pi@raspberrypi:~ $ ebusctl
            localhost: r Status01
            39.0;39.0;14.500;49.0;49.0;off

            Ich weiß auch nicht genau was die mirror Daten bedeuten und im FHEM Forum hab ich darauf auch keine Antwort bekommen. Dort ist John öffters mal. Die mirror Daten haben sicher nix mit der Rücklauftemperatur zu tun (siehe heute Werte um 65000 bei Vorlauf von 45 Grad).
            ReturnTemp6.JPG

            Danke für die Hilfe, grad bei dem Wetter

            Horst

            Rene_HM 2 Replies Last reply Reply Quote 0
            • Rene_HM
              Rene_HM Developer @Hasont last edited by

              @hasont okay, dann baue ich mal eine Version, die die mirror-Daten ignoriert (nur für die history). Im Datenbaum bleiben die weiter bestehen..

              1 Reply Last reply Reply Quote 0
              • Rene_HM
                Rene_HM Developer @Hasont last edited by

                @hasont kannst du mal die Version 2.2.4 von github installieren? Ich kann es leider hier nicht wirklich testen...

                Hasont 1 Reply Last reply Reply Quote 0
                • Hasont
                  Hasont @Rene_HM last edited by Hasont

                  @rene_hm
                  Hallo, finde leider nur den Master und wenn ich die 2.2.3 in 2.2.4 austausche kommt nix.
                  z.B. https://github.com/rg-engineering/ioBroker.ebus/tree/V2.2.4
                  Hast du eine URL mit der ich direkt über die Katze draufkomme?
                  Wird dann eine zweite Instanz angelegt oder überschreibt er die 2.2.3.

                  Schon mal vielen Dank für deine Bemühungen. Bin halt noch kein Profi 😉

                  Thomas Braun 1 Reply Last reply Reply Quote 0
                  • Thomas Braun
                    Thomas Braun Most Active @Hasont last edited by

                    @hasont

                    iobroker url https://github.com/rg-engineering/ioBroker.ebus
                    
                    Hasont 1 Reply Last reply Reply Quote 0
                    • Hasont
                      Hasont @Thomas Braun last edited by Hasont

                      @thomas-braun
                      Danke dir aber so komme ich auch nur auf den Master 2.2.3
                      Rene hat mir aber irgendwo eine 2.2.4 eingestellt und die kann ich leider nicht finden.

                      Rene_HM 1 Reply Last reply Reply Quote 0
                      • Rene_HM
                        Rene_HM Developer @Hasont last edited by

                        @hasont Im master-branch liegt aber 2.2.4, sieht man auch in der readme. Den tag V2.2.4 habe ich noch nicht gesetzt, die URL von @Thomas-Braun von oben ist also richtig.

                        bild.png

                        und ja, die Installation überschreibt die 2.2.3

                        Hasont 1 Reply Last reply Reply Quote 0
                        • Hasont
                          Hasont @Rene_HM last edited by Hasont

                          @rene_hm
                          Hallo Rene,
                          das hatte ich so schon probiert.
                          Hab jetzt Raspie reboot gemacht und nach dem das auch nicht geholfen hat habe ich die Histoty aus den Daten gelöscht.
                          Und siehe da nach der Neuanlage passt es jetzt.
                          ReturnTemp7.JPG
                          Vielen Dank du bist ein Schatz!!!

                          Nachtrag 22.02:
                          Hast du ev. noch einen Tip warum er nur ab und zu mal die X-Achse anzeigt.
                          ReturnTemp8.JPG
                          Selten kommt hier mal eine Uhrzeit meist aber gar nichts. Zoomen bringt auch nix.
                          Ist aber nicht weiter dramatisch.

                          LG
                          Horst

                          Rene_HM 1 Reply Last reply Reply Quote 0
                          • Rene_HM
                            Rene_HM Developer @Hasont last edited by

                            @hasont sagte in Adapter: ebus:

                            Hast du ev. noch einen Tip warum er nur ab und zu mal die X-Achse anzeigt.

                            Bisher gab es nur hin und wieder mal eine Meldung, dass die X-Achse gar nicht angezeigt wird. Aber sporadisch anzeigen und dann wieder nicht kenne ich noch nicht...
                            Schau dir mal das log in der Konsole des browsers an, evtl. siehst du da etwas, oder poste das log als Text hier...

                            1 Reply Last reply Reply Quote 0
                            • M
                              MaxPower 0 last edited by MaxPower 0

                              Hallo!
                              Habe den ebusd bei mir auch installiert, komme aber absolut nicht mehr weiter.

                              Es ist egal ob die config lokal oder im internet liegt - ich bekomme keine Daten ausgelesen. Ich nutze einen Raspi 3 inkl. dem esera USB Adapter. Dieser wird auch gefunden auf /dev/ttyUSB0

                              Wenn ich nun mir die Konfig aufrufe, dann wird keine Heizung (habe eine Vaillant geoTherm) gefunden. Das Ding ist - es hat schon funktioniert 😞

                              root@raspberrypi:/# ebusctl info
                              version: ebusd 21.2.v21.2
                              signal: acquired
                              symbol rate: 73
                              max symbol rate: 120
                              reconnects: 0
                              masters: 3
                              messages: 16
                              conditional: 0
                              poll: 0
                              update: 4
                              address 03: master #11
                              address 08: slave #11
                              address 10: master #2
                              address 23: slave
                              address 25: slave
                              address 31: master #8, ebusd
                              address 36: slave #8, ebusd
                              address 50: slave
                              

                              Ich finde den Fehler nicht und weiss gerade echt nicht weiter.

                              Meine Konfig aktuell:

                              EBUSD_OPTS="-d /dev/ttyUSB0 -p 8888 -l /var/log/ebusd.log --httpport=8889 --accesslevel=* --scanconfig=full --configpath=/home/pi/ebusd-configuration/ebusd-2.1.x/de"

                              Thomas Braun 1 Reply Last reply Reply Quote 0
                              • Thomas Braun
                                Thomas Braun Most Active @MaxPower 0 last edited by

                                @maxpower-0 sagte in Adapter: ebus:

                                Ich finde den Fehler nicht

                                Hier der erste Fehler:
                                root@raspberrypi

                                1 Reply Last reply Reply Quote 0
                                • M
                                  MaxPower 0 last edited by

                                  Danke für die schnelle Antwort. Ändert nur leider nichts.

                                  pi@raspberrypi:~ $ ebusctl info
                                  version: ebusd 21.2.v21.2
                                  access: *
                                  signal: acquired
                                  symbol rate: 85
                                  max symbol rate: 115
                                  reconnects: 0
                                  masters: 3
                                  messages: 16
                                  conditional: 0
                                  poll: 0
                                  update: 4
                                  address 03: master #11
                                  address 08: slave #11
                                  address 10: master #2
                                  address 23: slave
                                  address 25: slave
                                  address 31: master #8, ebusd
                                  address 36: slave #8, ebusd
                                  address 50: slave
                                  

                                  Und hier das log:

                                  2021-05-04 10:46:31.139 [main notice] ebusd 21.2.v21.2 started with full scan on device /dev/ttyUSB0
                                  2021-05-04 10:46:31.268 [bus notice] bus started with own address 31/36
                                  2021-05-04 10:46:31.269 [bus notice] signal acquired
                                  2021-05-04 10:46:32.125 [bus notice] new master 10, master count 2
                                  2021-05-04 10:46:32.142 [update notice] received unknown MS cmd: 1050b505042d000000 / 00
                                  2021-05-04 10:46:34.813 [update notice] received unknown BC cmd: 10feb5050427002c00
                                  2021-05-04 10:46:35.000 [update notice] received unknown MS cmd: 1050b5040100 / 0a03494611040502214009
                                  2021-05-04 10:46:36.183 [update notice] received unknown MS cmd: 1050b505072b000100000000 / 00
                                  2021-05-04 10:46:36.461 [bus notice] new master 03, master count 3
                                  2021-05-04 10:46:36.461 [update notice] received unknown MS cmd: 1008b5110103 / 0ac4028609b40503080000
                                  2021-05-04 10:46:36.628 [update notice] received unknown MS cmd: 1008b5110102 / 050000c800c8
                                  2021-05-04 10:46:39.572 [update notice] received unknown MS cmd: 1008b509040ed10001 / 00
                                  2021-05-04 10:46:40.163 [update notice] received unknown MS cmd: 1025b5040101 / 092d0300000003000100
                                  2021-05-04 10:46:40.329 [update notice] received unknown MS cmd: 1025b504010d / 050000c4022d
                                  2021-05-04 10:46:41.269 [main notice] starting initial full scan
                                  2021-05-04 10:46:44.150 [update notice] received unknown BC cmd: 10feb5050427002c00
                                  2021-05-04 10:46:46.164 [update notice] received unknown MS cmd: 1025b505072b000100000000 / 00
                                  2021-05-04 10:46:46.535 [update notice] received unknown MS cmd: 1008b5110103 / 0ac6028609b40503080000
                                  2021-05-04 10:46:46.700 [update notice] received unknown MS cmd: 1008b5110102 / 050000c800c8
                                  2021-05-04 10:46:48.255 [update notice] received unknown MS cmd: 1008b5090329d300 / 05d300636363
                                  2021-05-04 10:46:48.714 [update notice] received unknown MS cmd: 1008b509040ed10001 / 00
                                  2021-05-04 10:46:50.156 [update notice] received unknown MS cmd: 1025b509040ef40000 / 00
                                  2021-05-04 10:46:50.566 [update notice] received unknown MS cmd: 1023b5040101 / 091e0300000006000000
                                  2021-05-04 10:46:50.731 [update notice] received unknown MS cmd: 1023b504010d / 050000008000
                                  2021-05-04 10:46:50.905 [update notice] received unknown MS cmd: 1008b50903290f00 / 050f00a20100
                                  2021-05-04 10:46:51.071 [update notice] received unknown MS cmd: 1008b5090329bb00 / 03bb0000
                                  2021-05-04 10:46:51.239 [update notice] received unknown MS cmd: 1008b5090329ba00 / 03ba0000
                                  2021-05-04 10:47:06.252 [update notice] received unknown MS cmd: 1008b50903290300 / 050300af0200
                                  2021-05-04 10:47:07.632 [update notice] received unknown BC cmd: 10feb5050427002c00
                                  2021-05-04 10:47:08.113 [update notice] received unknown BC cmd: 10feb516080001471104050221
                                  2021-05-04 10:47:08.570 [update notice] received unknown BC cmd: 10feb51603014009
                                  2021-05-04 10:47:09.101 [update notice] received update-read broadcast datetime QQ=10: 9.250;11:47:01;04.05.2021
                                  2021-05-04 10:47:10.100 [update notice] received unknown MS cmd: 1023b505072b000100000000 / 00
                                  2021-05-04 10:47:10.748 [update notice] received unknown MS cmd: 1008b5110103 / 0ac9028609b40503080000
                                  2021-05-04 10:47:10.847 [main error] scan config 08: ERR: arbitration lost
                                  2021-05-04 10:47:10.912 [update notice] received unknown MS cmd: 1008b5110102 / 050000c800c8
                                  
                                  
                                  MassiveAttack 1 Reply Last reply Reply Quote 0
                                  • MassiveAttack
                                    MassiveAttack @MaxPower 0 last edited by

                                    @maxpower-0

                                    Versuchs mal mit --latency=30000 --receivetimeout=80000 und lass den configpath weg

                                    Den Esera USB Adapter hatte ich auch, funktionierte nur mit latency bei mir.

                                    1 Reply Last reply Reply Quote 0
                                    • M
                                      MaxPower 0 last edited by

                                      Danke für Deine Antwort - das hat leider am Ergebnis nichts verändert

                                      MassiveAttack 1 Reply Last reply Reply Quote 0
                                      • MassiveAttack
                                        MassiveAttack @MaxPower 0 last edited by

                                        @maxpower-0
                                        "arbitration lost" ist ein Timing Problem, also du solltest ggf. die latency erhöhen. Musst dich halt ein bisschen spielen damit...

                                        Ich hatte ein ähnliches Problem, musste ein paar Mal die Heizung bzw. den Adapter vom Strom nehmen, bis eine Config geladen wurde.
                                        Hab mir dann aber einen anderen Adapter gekauft, der funktioniert um Vieles besser.
                                        https://forum.fhem.de/index.php/topic,114988.0.html?PHPSESSID=tk16kvmfhcgekkmv07htjmduuu

                                        M 1 Reply Last reply Reply Quote 0
                                        • M
                                          MaxPower 0 @MassiveAttack last edited by

                                          @massiveattack said in Adapter: ebus:

                                          @maxpower-0
                                          "musste ein paar Mal die Heizung bzw. den Adapter vom Strom nehmen, bis eine Config geladen wurde."

                                          DANKE

                                          Das war es - hab heute morgen die Heizung neu gestartet und schon klappte alles. Darauf hätte ich auch früher kommen können. DANKE!

                                          1 Reply Last reply Reply Quote 0
                                          • P
                                            PaiRo last edited by

                                            Hallo zusammen,

                                            ich bin neu in diesem Thema und dies ist auch mein erster Post, bisher konnte ich alles lösen dank diesem Forum allerdings komme ich jetzt nicht weiter. Versuche seit 1,5Wochen den Ebus Adapter von Esera ans laufen zu bekommen.

                                            Meine Anlage:
                                            Therme - VC266/5-5
                                            VMS 8 - Solarstation
                                            VRC 700/6 Multimatic

                                            meine aktuelle config:

                                            EBUSD_OPTS="-d /dev/ttyUSB0 -p 8888  --latency=10000 --receivetimeout=100000 -l /var/log/ebusd.log --configpath=/etc/ebusd  --scanconfig=full  --httpport=8889 --htmlpath=/var/ebusd/html"
                                            

                                            Ausgabe status:

                                            root@raspberrypi:/home/pi# service ebusd status
                                            ● ebusd.service - LSB: controls ebusd, the daemon for communication with eBUS heating systems.
                                               Loaded: loaded (/etc/init.d/ebusd; generated)
                                               Active: active (running) since Fri 2021-07-02 15:09:31 CEST; 23min ago
                                                 Docs: man:systemd-sysv-generator(8)
                                              Process: 4395 ExecStart=/etc/init.d/ebusd start (code=exited, status=0/SUCCESS)
                                                Tasks: 4 (limit: 4915)
                                               CGroup: /system.slice/ebusd.service
                                                       └─4402 /usr/bin/ebusd --pidfile /var/run/ebusd.pid -d /dev/ttyUSB0 -p 8888 --latency=10000 --receivetimeout=100000 -l /var/log/ebusd.log --configpath=/etc/ebusd --scanconfig=ful
                                            
                                            Jul 02 15:09:31 raspberrypi systemd[1]: Starting LSB: controls ebusd, the daemon for communication with eBUS heating systems....
                                            Jul 02 15:09:31 raspberrypi ebusd[4395]: Starting ebusd: ebusd.
                                            Jul 02 15:09:31 raspberrypi systemd[1]: Started LSB: controls ebusd, the daemon for communication with eBUS heating systems..
                                            

                                            Ausgabe info:

                                            root@raspberrypi:/home/pi# ebusctl i
                                            version: ebusd 21.2.v21.2
                                            signal: acquired
                                            symbol rate: 38
                                            max symbol rate: 150
                                            min arbitration micros: 622
                                            max arbitration micros: 3982
                                            min symbol latency: 2
                                            max symbol latency: 11
                                            reconnects: 0
                                            masters: 3
                                            messages: 214
                                            conditional: 3
                                            poll: 0
                                            update: 10
                                            address 03: master #11
                                            address 08: slave #11, scanned "MF=Vaillant;ID=BAI00;SW=0104;HW=7803", loaded "vaillant/bai.308523.inc", "vaillant/08.bai.csv"
                                            address 10: master #2
                                            address 15: slave #2, scanned "MF=Vaillant;ID=70000;SW=0613;HW=6903"
                                            address 31: master #8, ebusd
                                            address 36: slave #8, ebusd
                                            address ed: slave, scanned "MF=Vaillant;ID=VMS02;SW=0108;HW=1703"
                                            

                                            ich weis nicht wieso er die csv für die Geräte "ID=7000" und "ID=VMS02" nicht lädt. Hoffe es kann mir jemand helfen, habe das forum gefühlt 100 mal durchgelesen.

                                            Thomas Braun Glasfaser 2 Replies Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate
                                            FAQ Cloud / IOT
                                            HowTo: Node.js-Update
                                            HowTo: Backup/Restore
                                            Downloads
                                            BLOG

                                            570
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            ebus adapter
                                            68
                                            677
                                            148790
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo