      Geile Sache, das läuft wie geschmiert mit über 140 devices.. !

      2021-03-06 10:12:26.836  - info: zigbee.0 (30863) Starting Zigbee  npm ...
      2021-03-06 10:12:27.760  - info: zigbee.0 (30863) Installed Version: iobroker.zigbee@1.4.4
      2021-03-06 10:12:29.794  - info: zigbee.0 (30863) Coordinator firmware version: {"type":"zStack3x0","meta":{"transportrev":2,"product":1,"majorrel":2,"minorrel":7,"maintrel":1,"revision":20210120}}
      2021-03-06 10:12:29.804  - info: zigbee.0 (30863) Unable to disable LED, unsupported function.
      2021-03-06 10:12:29.805  - info: zigbee.0 (30863)   --> transmitPower : high
      2021-03-06 10:12:29.834  - info: zigbee.0 (30863) Currently 145 devices are joined:
      
      
      M 1 Reply Last reply Reply Quote 0
      • M
        MartyBr @Neuschwansteini last edited by

        @ilovegym
        Mit welchem Chipsatz arbeitest du?

        Neuschwansteini 1 Reply Last reply Reply Quote 0
        • Neuschwansteini
          Neuschwansteini @MartyBr last edited by Neuschwansteini

          @martybr hab ein cc26x2r1 direkt bei TI bestellt, war innerhalb 5 Tagen hier.

          1e9078c4-ebc8-4faa-91a0-c2df790f95ef-grafik.png

          M L 2 Replies Last reply Reply Quote 0
          • M
            MartyBr @Neuschwansteini last edited by

            @ilovegym Deine Zahl der Geräte ist beeindruckend. Ich fange gerade mit Zigbee an und habe mir (auch bei TI) eine Entwicklungsboard cc1352P geholt. Das hat direkt einen USB Anschluß auf dem Board zum flachen der Firmware. Das war der entscheidende Grund für die Wahl des Boards.
            Geht das beim cc26x2r1 auch? Das Board scheint ja leistungsfähiger als das 1352 zu sein.

            Neuschwansteini arteck 2 Replies Last reply Reply Quote 0
            • Neuschwansteini
              Neuschwansteini @MartyBr last edited by

              @martybr

              ja, das CC26x2r1 auch, ist total easy zu flashen, hab noch eins hier, als Ersatz (inwieweit das im Falle des Falles anzuwenden ist, weiss ich nicht, aber ich muss dann wenigstens nicht tagelang warten, bis ein neues da ist..)
              Das anlernen war schon ne Aufgabe, vor allem, da die Sensoren ja überall verbaut sind..

              Meine Sensoren sind teilweise über 3 Jahre alt ( Xiaomi ) und vorher hatte 130 devices mit 9 xiaomi Gateways ausgewertet. Da die Gateways aber im Wifi sind, gabs immer mal n Verbindungsproblem, und daher sind die jetzt rausgeflogen.

              Der CC26x2r1 haengt per USB am Raspi3, der als Client am iobroker (lxc debian 10, proxmox, auf HP Proliant Gen8 mit 132gb Ram, 2x Xeon E5-2680 ) sich langweilt..

              Ich versorge damit ein Zweifamilienhaus mit 4 Etagen und den Aussenbereich.

              T 1 Reply Last reply Reply Quote 0
              • T
                tony63526 @Neuschwansteini last edited by

                @ilovegym

                Du Glücklicher...
                Mein Adapter muckt die ganze Zeit rum seit ich auf 1.4.4 umgestiegen bin.
                Reihenmittelhaus und der Ikea Repeater wir für 1-2 Stunden im Obergeschoss erkannt nachdem ich ihn angelernt habe und dann verliert er die Verbindung. Komischerweise wird der Xiaomisensor im Bad Dachgeschoss erkannt Link Quality=3.

                Im Zigbeeadapter verschwindet nach einer mir undefinierte Zeit der Icon für die EINSTELLUNG und taucht erst wieder auf wenn ich den Adapter pausiere und wieder Starte.
                Den Adapter habe ich gelöscht oder wieder neu aufgespielt. Hat nicht geholfen.
                Jetzt lebe ich erst mal damit. Dem Zigbee Netzwerk soll man ja etwas Zeit geben!

                Unbenannt.JPG

                Asgothian 1 Reply Last reply Reply Quote 0
                • Asgothian
                  Asgothian Developer @tony63526 last edited by

                  @tony63526 Bist du sicher das du in die korrekte Ansicht wechselst ?

                  der Zigbee Adapter hat 2 Ansichten über die man an die Geräte heran kommt. Allerdings hat nur eine der Beiden Zugriff auf die Einstellungen:
                  Screen Shot 2021-03-06 at 15.23.09 .png

                  Screen Shot 2021-03-06 at 15.23.27 .png

                  A.

                  T K 2 Replies Last reply Reply Quote 0
                  • T
                    tony63526 @Asgothian last edited by

                    @asgothian
                    Error by user ...
                    Du hast recht.
                    War mir gar nicht bewusst gewesen das es bei der anderen Ansicht nicht Sichtbar ist. Deshalb undefinierbare Zeit hahaha
                    Danke

                    Asgothian 1 Reply Last reply Reply Quote 0
                    • K
                      klassisch Most Active @Asgothian last edited by klassisch

                      @asgothian sagte in ZigBee neue Version 1.4.4:

                      der Zigbee Adapter hat 2 Ansichten über die man an die Geräte heran kommt.

                      Interessant. Bei mir sehe ich nur die Ansicht unter Instanzen.
                      Die Ansicht unterhalb von "Hosts" sehe ich nicht.

                      Asgothian 1 Reply Last reply Reply Quote 0
                      • Asgothian
                        Asgothian Developer @klassisch last edited by

                        @klassisch Screen Shot 2021-03-06 at 16.01.06 .png

                        1 Reply Last reply Reply Quote 1
                        • Asgothian
                          Asgothian Developer @tony63526 last edited by

                          @tony63526 sagte in ZigBee neue Version 1.4.4:

                          Error by user ...

                          Fein. Ansonsten hätten wir da wirklich nen grösseren Bug. Bin ich doch Froh das der in diesem Fall vor dem Rechner saß 😉

                          1 Reply Last reply Reply Quote 0
                          • L
                            locito09 @Neuschwansteini last edited by

                            @ilovegym
                            Was für Geräte hast du als Router genommen?
                            Hast du eine Antenne beim cc26x2r1?

                            Neuschwansteini 1 Reply Last reply Reply Quote 0
                            • Neuschwansteini
                              Neuschwansteini @locito09 last edited by

                              @locito09
                              Xiaomi smart Plug, funktionieren super, hab 6 Stück im Haus verteilt und in der Garage.

                              Hatte erst ledvance, aber da wollte sich kein devices mit verbinden...

                              Am cc26x2r1 hab ich keine Antenne, ohne Router komme ich hier Dank Stahlbeton Wänden sowieso nicht weit...

                              L 1 Reply Last reply Reply Quote 1
                              • L
                                locito09 @Neuschwansteini last edited by

                                @ilovegym

                                Welchen Plug genau hast du?
                                5E306EC9-C686-4158-89AB-03FB16D89CF8.png

                                Neuschwansteini 1 Reply Last reply Reply Quote 0
                                • Neuschwansteini
                                  Neuschwansteini @locito09 last edited by

                                  @locito09
                                  einen uralten mit Chinastecker, mit EU Adapter aber da betreibe ich keine Last drüber:
                                  f3fde303-d832-45e9-9d1b-090b7a05fbbb-grafik.png

                                  und 6 von der EU-Version, haben auch viele Sonderfunktionen, echt tolle features:
                                  45373776-f490-4df6-b0f8-d655d533603a-grafik.png

                                  L 1 Reply Last reply Reply Quote 1
                                  • L
                                    locito09 @Neuschwansteini last edited by locito09

                                    @ilovegym
                                    Super vielen Dank, wurden Bestellt

                                    Eine frage habe ich noch dienen die plug als repeater und router oder hast du noch repeater separat im Einsatz.
                                    Oder anders gefragt kann ich meine Ikea Repeater mit diesen Router ersetzen

                                    Neuschwansteini 1 Reply Last reply Reply Quote 1
                                    • K
                                      klassisch Most Active last edited by

                                      Habe ja ab und an Aussetzer des zigbee Adapters mit Verlust der USB Verbindung.
                                      Monitore das Thema jetzt etwas genauer und habe festgestellt, daß der Adapter sich manchmal wieder von alleine verbindet und manchmal scheitert.
                                      Habe jetzt 2 Ereignisse untersucht und jedesmal waren zeitgleich Probleme mit USB-Platte(n) in der Win Ereignsanzeige zu sehen.

                                      schauen wir ein Ereignis vom 5.3. etwas genauer an:

                                      Disconnect 2021-03-05 23:39

                                      Der Adapter hat

                                      • diconnected
                                      • connected
                                      • disconnected

                                      ioBroker log (aus logfile, vorsortiert, es sollten nur die Zigee Meldungen drin sein)

                                      [s=]
                                      2021-03-05 23:39:11.099 - error: zigbee.0 (10716) Adapter disconnected, stopping
                                      2021-03-05 23:39:11.100 - error: zigbee.0 (10716) Adapter disconnected, stopping
                                      2021-03-05 23:39:21.108 - info: zigbee.0 (10716) Try to reconnect. 5 attempts left
                                      2021-03-05 23:39:21.109 - info: zigbee.0 (10716) Starting Zigbee npm ...
                                      2021-03-05 23:39:21.109 - info: zigbee.0 (10716) Try to reconnect. 4 attempts left
                                      2021-03-05 23:39:21.109 - info: zigbee.0 (10716) Starting Zigbee npm ...
                                      2021-03-05 23:39:21.120 - error: zigbee.0 (10716) Failed to start Zigbee
                                      2021-03-05 23:39:21.120 - error: zigbee.0 (10716) Error: Error while opening serialport 'Error: Opening COM6: File not found'
                                      at Znp. (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:136:32)
                                      at Generator.next ()
                                      at C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:27:71
                                      at new Promise ()
                                      at __awaiter (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:23:12)
                                      at SerialPort.serialPort.open (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:134:49)
                                      at SerialPort._error (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\node_modules\@serialport\stream\lib\index.js:198:14)
                                      at binding.open.then.err (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\node_modules\@serialport\stream\lib\index.js:242:12)
                                      2021-03-05 23:39:21.121 - error: zigbee.0 (10716) Failed to start Zigbee
                                      2021-03-05 23:39:21.121 - error: zigbee.0 (10716) Error: Error while opening serialport 'Error: Opening COM6: File not found'
                                      at Znp. (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:136:32)
                                      at Generator.next ()
                                      at C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:27:71
                                      at new Promise ()
                                      at __awaiter (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:23:12)
                                      at SerialPort.serialPort.open (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:134:49)
                                      at SerialPort._error (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\node_modules\@serialport\stream\lib\index.js:198:14)
                                      at binding.open.then.err (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\node_modules\@serialport\stream\lib\index.js:242:12)
                                      2021-03-05 23:39:21.122 - info: zigbee.0 (10716) Installed Version: ioBroker/ioBroker.zigbee#fb7f21f61993e249e9979d85632c1abe19a121b1
                                      2021-03-05 23:39:21.123 - info: zigbee.0 (10716) Installed Version: ioBroker/ioBroker.zigbee#fb7f21f61993e249e9979d85632c1abe19a121b1
                                      2021-03-05 23:39:31.122 - info: zigbee.0 (10716) Try to reconnect. 3 attempts left
                                      2021-03-05 23:39:31.124 - info: zigbee.0 (10716) Starting Zigbee npm ...
                                      2021-03-05 23:39:31.124 - info: zigbee.0 (10716) Try to reconnect. 2 attempts left
                                      2021-03-05 23:39:31.125 - info: zigbee.0 (10716) Starting Zigbee npm ...
                                      2021-03-05 23:39:31.137 - error: zigbee.0 (10716) Failed to start Zigbee
                                      2021-03-05 23:39:31.137 - error: zigbee.0 (10716) Error: Error while opening serialport 'Error: Opening COM6: Access denied'
                                      at Znp. (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:136:32)
                                      at Generator.next ()
                                      at C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:27:71
                                      at new Promise ()
                                      at __awaiter (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:23:12)
                                      at SerialPort.serialPort.open (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:134:49)
                                      at SerialPort._error (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\node_modules\@serialport\stream\lib\index.js:198:14)
                                      at binding.open.then.err (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\node_modules\@serialport\stream\lib\index.js:242:12)
                                      2021-03-05 23:39:31.138 - info: zigbee.0 (10716) Installed Version: ioBroker/ioBroker.zigbee#fb7f21f61993e249e9979d85632c1abe19a121b1
                                      2021-03-05 23:39:31.139 - info: zigbee.0 (10716) Installed Version: ioBroker/ioBroker.zigbee#fb7f21f61993e249e9979d85632c1abe19a121b1
                                      2021-03-05 23:39:32.672 - error: zigbee.0 (10716) Failed to start Zigbee
                                      2021-03-05 23:39:32.672 - error: zigbee.0 (10716) TypeError: Cannot read property 'execute' of undefined
                                      at ZStackAdapter. (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\adapter\zStackAdapter.js:133:31)
                                      at Generator.next ()
                                      at C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\adapter\zStackAdapter.js:27:71
                                      at new Promise ()
                                      at __awaiter (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\adapter\zStackAdapter.js:23:12)
                                      at ZStackAdapter.getCoordinator (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\adapter\zStackAdapter.js:132:16)
                                      at Controller. (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\controller\controller.js:136:52)
                                      at Generator.next ()
                                      at fulfilled (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\controller\controller.js:24:58)
                                      2021-03-05 23:39:35.600 - warn: zigbee.0 (10716) Failed to ping 0xbc33acfffed7b833 FLOALT panel WS 60x60
                                      2021-03-05 23:39:36.523 - warn: zigbee.0 (10716) Failed to ping 0xbc33acfffed57c9d FLOALT panel WS 60x60
                                      2021-03-05 23:39:41.150 - info: zigbee.0 (10716) Try to reconnect. 1 attempts left
                                      2021-03-05 23:39:41.153 - info: zigbee.0 (10716) Starting Zigbee npm ...
                                      2021-03-05 23:39:41.169 - error: zigbee.0 (10716) Failed to start Zigbee
                                      2021-03-05 23:39:41.170 - error: zigbee.0 (10716) Error: Error while opening serialport 'Error: Opening COM6: Access denied'
                                      at Znp. (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:136:32)
                                      at Generator.next ()
                                      at C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:27:71
                                      at new Promise ()
                                      at __awaiter (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:23:12)
                                      at SerialPort.serialPort.open (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:134:49)
                                      at SerialPort._error (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\node_modules\@serialport\stream\lib\index.js:198:14)
                                      at binding.open.then.err (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\node_modules\@serialport\stream\lib\index.js:242:12)
                                      2021-03-05 23:39:41.173 - info: zigbee.0 (10716) Installed Version: ioBroker/ioBroker.zigbee#fb7f21f61993e249e9979d85632c1abe19a121b1
                                      2021-03-05 23:39:42.676 - info: zigbee.0 (10716) Try to reconnect. 0 attempts left
                                      2021-03-05 23:39:42.677 - info: zigbee.0 (10716) Starting Zigbee npm ...
                                      2021-03-05 23:39:42.682 - error: zigbee.0 (10716) Failed to start Zigbee
                                      2021-03-05 23:39:42.682 - error: zigbee.0 (10716) Error: Error while opening serialport 'Error: Opening COM6: Access denied'
                                      at Znp. (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:136:32)
                                      at Generator.next ()
                                      at C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:27:71
                                      at new Promise ()
                                      at __awaiter (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:23:12)
                                      at SerialPort.serialPort.open (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\dist\adapter\z-stack\znp\znp.js:134:49)
                                      at SerialPort._error (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\node_modules\@serialport\stream\lib\index.js:198:14)
                                      at binding.open.then.err (C:\Program Files\iobroker\ioBrMain026\node_modules\zigbee-herdsman\node_modules\@serialport\stream\lib\index.js:242:12)
                                      2021-03-05 23:39:42.684 - info: zigbee.0 (10716) Installed Version: ioBroker/ioBroker.zigbee#fb7f21f61993e249e9979d85632c1abe19a121b1
                                      [/s]
                                      

                                      zugehörige Windows Ereinisanzeige des ioBroker tragenden Rechners (Win 10, Laptop)

                                      Etliche Eintrage im Stil:

                                      Bei einem Auslagerungsvorgang wurde ein Fehler festgestellt. Betroffen ist Gerät \Device\Harddisk1\DR6.
                                      

                                      Dann irgendwann:

                                      Volume "F:" (\Device\HarddiskVolume21) ist fehlerfrei. Es ist keine Aktion erforderlich.
                                      

                                      kurz darauf wieder Fehlermeldungen diese Platte betreffend. Und dann

                                      System call failed: WinUsb_ControlTransfer: 433.
                                      

                                      Danch wieder alles i.O.

                                      Volume "F:" (\Device\HarddiskVolume24) ist fehlerfrei. Es ist keine Aktion erforderlich.
                                      

                                      Aber dann war es für den zigbee Adapter wohl schon zu spät

                                      Auf dieser Platte liegen die ioBroker history Daten und weitere Daten, die kontininuierlich geschrieben werden
                                      Die Platte ist über USB3.0 angebunden, es ist eine 4TB WD purple, also dauerbetriebtauglich. Der USB-Sata Adapter ist ein billiger Aufsteckadapter, der im Hardware Manager als "sobetter EXT SCSI DRIVE" erkannt wird.

                                      Innerhalb dieses Zeitfensters (max 30 Sekunden Dauer) gab es auch Fehlermeldungen zu einer anderen USB-Platte:

                                      Bei einem Auslagerungsvorgang wurde ein Fehler festgestellt. Betroffen ist Gerät \Device\Harddisk2\DR10.
                                      

                                      Das ist eine weitere USB-Platte, die aber in der Regel um diese Zeit idle ist. Läßt aber auf irgendeinen USB Fehler oder Überlastung schließen.

                                      Einen ähnlichen Zwischenfall gab es heute morgen wieder, aber kürzer. Das USB-Zeug und der zigbee Adapter haben sich da wieder gefangen und der Adapter ist gleich online gegangen.

                                      Sofortmassnahme: Werde den kostengünstigen USB-SATA Adapter durch ein Orico Gehäuse ersetzen und weiter beobachten

                                      Thomas Braun Neuschwansteini 2 Replies Last reply Reply Quote 0
                                      • Thomas Braun
                                        Thomas Braun Most Active @klassisch last edited by

                                        @klassisch Die Platten haben eine eigene Stromversorgung oder nuckeln die am USB-Bus?

                                        K 1 Reply Last reply Reply Quote 1
                                        • Neuschwansteini
                                          Neuschwansteini @klassisch last edited by

                                          @klassisch

                                          ein Vorschlag meinerseits, bevor du in weitere USB Hardware investierst...

                                          Ersetze Windows durch linux. 🙂

                                          Diese eigenwilligen Windowstreiber die irgendwo durch ein update geändert werden und dir dann in 4 Wochen die nächsten Probleme machen.. das bringt einem zum Wahnsinn..

                                          K 1 Reply Last reply Reply Quote 2
                                          • K
                                            klassisch Most Active @Thomas Braun last edited by

                                            @thomas-braun Alles 3.5 Zoll Platten mit eigenen 12V Versorgungen.

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            832
                                            Online

                                            31.7k
                                            Users

                                            79.9k
                                            Topics

                                            1.3m
                                            Posts

                                            neue version zigbee zigbee neue version 1.4.0
                                            35
                                            302
                                            38327
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo