    4. [Vorlage] Generische Batteriestandsüberwachung + Vis-ausgabe

    NEWS

    • Neuer Blog: Fotos und Eindrücke aus Solingen

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    [Vorlage] Generische Batteriestandsüberwachung + Vis-ausgabe

    This topic has been deleted. Only users with topic management privileges can see it.
    • P
      passuff @Pittini last edited by

      @pittini Wie berechnest du die Prozent? Linear oder nach Zellentyp?

      P 1 Reply Last reply Reply Quote 0
      • P
        Pittini Developer @passuff last edited by

        @passuff sagte in [Vorlage] Generische Batteriestandsüberwachung + Vis-ausgabe:

        @pittini Wie berechnest du die Prozent? Linear oder nach Zellentyp?

        Versteh grad die Frage nicht.

        P 1 Reply Last reply Reply Quote 0
        • P
          passuff @Pittini last edited by

          @pittini Ich würde gerne deine Berechnungsmethode verstehen. Beispiel:
          Zellentyp: Ni-MH
          Max: 1.4V
          Min: 1.2V
          MinMax: 0.22V/100%
          Ist: 1.3V
          Was gibst du als Prozentwert aus? 50% oder oder eher in Richtung 25%?
          Korrekt wäre vermutlich ca. 25% aufgrund des stark nichtlinearen Verlaufs der Kurve Spannung über SoC bei Ni-MH und dem sehr langsamen entladen. Hier ein paar Details:

          http://aacycler.com/post/nimh-open-circuit-voltage-vs-state-of-charge/

          P 1 Reply Last reply Reply Quote 0
          • P
            Pittini Developer @passuff last edited by Pittini

            @passuff Zeile 186 - dürfte selbsterklärend sein. Alles simple Prozentrechnung, linear. Ich mach da kein Gedöns, das stimmt eh nie genau, da müsste man noch die Temperatur mit berücksichtigen, welcher Akkutyp, bla und blupp.

            P 1 Reply Last reply Reply Quote 0
            • P
              passuff @Pittini last edited by

              @pittini
              verstehe...
              6935ec07-4e96-4348-bad6-9bd61221213a-image.png
              Warum ist lfd 15 gelb und was bedeutet info?
              Warum ist lfd 10 nicht rot? % life ist ja bereits 0%...

              P 1 Reply Last reply Reply Quote 0
              • P
                Pittini Developer @passuff last edited by Pittini

                @passuff sagte in [Vorlage] Generische Batteriestandsüberwachung + Vis-ausgabe:

                @pittini
                verstehe...
                6935ec07-4e96-4348-bad6-9bd61221213a-image.png
                Warum ist lfd 15 gelb und was bedeutet info?

                Auszug aus der Anleitung:
                "Gesondert markiert (in der Grundeinstellung gelb) wird die Zeile des Gerätes mit dem niedrigsten prozentualen Batteriestand welches sich aber noch innerhalb des festgelegten Limits befindet (hier werden Geräte welche nur Lowbat true/false liefern aufgrund der mangelnden Daten nicht berücksichtigt)."

                Warum ist lfd 10 nicht rot? % life ist ja bereits 0%...

                Sollte bei 2,19V dann rot werden, ansonsten Screenshot der Zuweisung? Log?

                P 1 Reply Last reply Reply Quote 0
                • P
                  passuff @Pittini last edited by

                  @pittini sagte in [Vorlage] Generische Batteriestandsüberwachung + Vis-ausgabe:

                  en Geräte welche nur Lowbat true/false liefern aufgrund der mangelnden Daten nicht b

                  Verstanden, aber sollte nicht lfd 10 gelb sein?

                  Zuweisung:
                  b3bf1e8f-d3ad-4ade-a64d-cdfba3bcff99-image.png

                  Log:

                  2021-03-09 09:49:10.611  - info: javascript.0 (2876) Stop script script.js.common.Batteriestatus.Überwachung_Batterie_HM
                  2021-03-09 09:49:10.809  - info: javascript.0 (2876) Start javascript script.js.common.Batteriestatus.Überwachung_Batterie_HM
                  2021-03-09 09:49:10.823  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: starting Batterieüberwachung V.1.7.2
                  2021-03-09 09:49:10.824  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Reaching FillWelcheFunktionVerwenden
                  2021-03-09 09:49:10.824  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Found Function BatterieHomematic_15
                  2021-03-09 09:49:10.824  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Found Function BatterieHomematic_30
                  2021-03-09 09:49:10.825  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: InitialSpannung 0 gesetzt auf 80%= 1.2
                  2021-03-09 09:49:10.825  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: InitialSpannung 1 gesetzt auf 80%= 2.4
                  2021-03-09 09:49:10.837  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: registered 0 subscriptions and 0 schedules
                  2021-03-09 09:49:10.881  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: CreateStates fertig!
                  2021-03-09 09:49:10.882  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Reaching main()
                  2021-03-09 09:49:10.882  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Reaching init()
                  2021-03-09 09:49:10.883  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: BattMinLimit Value conversion - success
                  2021-03-09 09:49:10.883  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=boolean getState(Sensor[counter]).val=false
                  2021-03-09 09:49:10.890  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=false TempUnit=undefined TypeOf=boolean
                  2021-03-09 09:49:10.890  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 0 BatterieHomematic_15 found at hm-rpc.0.OEQ0708741.0.LOWBAT Umax= 1.5 BattMinLimit=1.1 Val= 1.5 SensorProzent= 100
                  2021-03-09 09:49:10.890  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=boolean getState(Sensor[counter]).val=false
                  2021-03-09 09:49:10.890  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=false TempUnit=undefined TypeOf=boolean
                  2021-03-09 09:49:10.891  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 1 BatterieHomematic_15 found at hm-rpc.0.OEQ0708748.0.LOWBAT Umax= 1.5 BattMinLimit=1.1 Val= 1.5 SensorProzent= 100
                  2021-03-09 09:49:10.891  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=boolean getState(Sensor[counter]).val=false
                  2021-03-09 09:49:10.891  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=false TempUnit=undefined TypeOf=boolean
                  2021-03-09 09:49:10.891  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 2 BatterieHomematic_15 found at hm-rpc.0.OEQ0709520.0.LOWBAT Umax= 1.5 BattMinLimit=1.1 Val= 1.5 SensorProzent= 100
                  2021-03-09 09:49:10.891  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=boolean getState(Sensor[counter]).val=false
                  2021-03-09 09:49:10.892  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=false TempUnit=undefined TypeOf=boolean
                  2021-03-09 09:49:10.892  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 3 BatterieHomematic_15 found at hm-rpc.0.OEQ0709589.0.LOWBAT Umax= 1.5 BattMinLimit=1.1 Val= 1.5 SensorProzent= 100
                  2021-03-09 09:49:10.892  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=boolean getState(Sensor[counter]).val=false
                  2021-03-09 09:49:10.892  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=false TempUnit=undefined TypeOf=boolean
                  2021-03-09 09:49:10.893  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 4 BatterieHomematic_15 found at hm-rpc.0.OEQ1424242.0.LOWBAT Umax= 1.5 BattMinLimit=1.1 Val= 1.5 SensorProzent= 100
                  2021-03-09 09:49:10.893  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=boolean getState(Sensor[counter]).val=false
                  2021-03-09 09:49:10.893  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=false TempUnit=undefined TypeOf=boolean
                  2021-03-09 09:49:10.896  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 5 BatterieHomematic_15 found at hm-rpc.0.OEQ1424270.0.LOWBAT Umax= 1.5 BattMinLimit=1.1 Val= 1.5 SensorProzent= 100
                  2021-03-09 09:49:10.897  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=boolean getState(Sensor[counter]).val=false
                  2021-03-09 09:49:10.897  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=false TempUnit=undefined TypeOf=boolean
                  2021-03-09 09:49:10.897  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 6 BatterieHomematic_15 found at hm-rpc.0.OEQ1424271.0.LOWBAT Umax= 1.5 BattMinLimit=1.1 Val= 1.5 SensorProzent= 100
                  2021-03-09 09:49:10.897  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=boolean getState(Sensor[counter]).val=false
                  2021-03-09 09:49:10.897  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=false TempUnit=undefined TypeOf=boolean
                  2021-03-09 09:49:10.898  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 7 BatterieHomematic_15 found at hm-rpc.0.OEQ1424294.0.LOWBAT Umax= 1.5 BattMinLimit=1.1 Val= 1.5 SensorProzent= 100
                  2021-03-09 09:49:10.898  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: BattMinLimit Value conversion - success
                  2021-03-09 09:49:10.898  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=number getState(Sensor[counter]).val=2.2
                  2021-03-09 09:49:10.898  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=2.2 TempUnit=V TypeOf=number
                  2021-03-09 09:49:10.899  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 8 BatterieHomematic_30 found at hm-rpc.0.OEQ0860057.4.BATTERY_STATE Umax= 3 BattMinLimit=2.2 Val= 2.2 SensorProzent= 73.33333333333334
                  2021-03-09 09:49:10.899  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=number getState(Sensor[counter]).val=2.5
                  2021-03-09 09:49:10.899  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=2.5 TempUnit=V TypeOf=number
                  2021-03-09 09:49:10.899  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 9 BatterieHomematic_30 found at hm-rpc.0.OEQ1711771.4.BATTERY_STATE Umax= 3 BattMinLimit=2.2 Val= 2.5 SensorProzent= 83.33333333333334
                  2021-03-09 09:49:10.899  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=number getState(Sensor[counter]).val=2.5
                  2021-03-09 09:49:10.900  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=2.5 TempUnit=V TypeOf=number
                  2021-03-09 09:49:10.900  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 10 BatterieHomematic_30 found at hm-rpc.0.OEQ1711789.4.BATTERY_STATE Umax= 3 BattMinLimit=2.2 Val= 2.5 SensorProzent= 83.33333333333334
                  2021-03-09 09:49:10.900  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=number getState(Sensor[counter]).val=2.6
                  2021-03-09 09:49:10.900  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=2.6 TempUnit=V TypeOf=number
                  2021-03-09 09:49:10.901  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 11 BatterieHomematic_30 found at hm-rpc.0.OEQ1711818.4.BATTERY_STATE Umax= 3 BattMinLimit=2.2 Val= 2.6 SensorProzent= 86.66666666666667
                  2021-03-09 09:49:10.901  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=number getState(Sensor[counter]).val=2.5
                  2021-03-09 09:49:10.901  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=2.5 TempUnit=V TypeOf=number
                  2021-03-09 09:49:10.907  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 12 BatterieHomematic_30 found at hm-rpc.0.OEQ1711819.4.BATTERY_STATE Umax= 3 BattMinLimit=2.2 Val= 2.5 SensorProzent= 83.33333333333334
                  2021-03-09 09:49:10.907  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=number getState(Sensor[counter]).val=2.4
                  2021-03-09 09:49:10.908  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=2.4 TempUnit=V TypeOf=number
                  2021-03-09 09:49:10.908  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 13 BatterieHomematic_30 found at hm-rpc.0.OEQ1711829.4.BATTERY_STATE Umax= 3 BattMinLimit=2.2 Val= 2.4 SensorProzent= 80
                  2021-03-09 09:49:10.908  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=number getState(Sensor[counter]).val=2.5
                  2021-03-09 09:49:10.908  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=2.5 TempUnit=V TypeOf=number
                  2021-03-09 09:49:10.909  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 14 BatterieHomematic_30 found at hm-rpc.0.OEQ1711834.4.BATTERY_STATE Umax= 3 BattMinLimit=2.2 Val= 2.5 SensorProzent= 83.33333333333334
                  2021-03-09 09:49:10.909  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=number getState(Sensor[counter]).val=2.5
                  2021-03-09 09:49:10.909  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=2.5 TempUnit=V TypeOf=number
                  2021-03-09 09:49:10.909  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 15 BatterieHomematic_30 found at hm-rpc.0.OEQ1711836.4.BATTERY_STATE Umax= 3 BattMinLimit=2.2 Val= 2.5 SensorProzent= 83.33333333333334
                  2021-03-09 09:49:10.909  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=number getState(Sensor[counter]).val=2.5
                  2021-03-09 09:49:10.910  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=2.5 TempUnit=V TypeOf=number
                  2021-03-09 09:49:10.910  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 16 BatterieHomematic_30 found at hm-rpc.0.OEQ1714864.4.BATTERY_STATE Umax= 3 BattMinLimit=2.2 Val= 2.5 SensorProzent= 83.33333333333334
                  2021-03-09 09:49:10.910  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=number getState(Sensor[counter]).val=2.5
                  2021-03-09 09:49:10.910  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=2.5 TempUnit=V TypeOf=number
                  2021-03-09 09:49:10.911  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 17 BatterieHomematic_30 found at hm-rpc.0.OEQ1715250.4.BATTERY_STATE Umax= 3 BattMinLimit=2.2 Val= 2.5 SensorProzent= 83.33333333333334
                  2021-03-09 09:49:10.911  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=number getState(Sensor[counter]).val=2.5
                  2021-03-09 09:49:10.911  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=2.5 TempUnit=V TypeOf=number
                  2021-03-09 09:49:10.911  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 18 BatterieHomematic_30 found at hm-rpc.0.OEQ1675616.2.BATTERY_STATE Umax= 3 BattMinLimit=2.2 Val= 2.5 SensorProzent= 83.33333333333334
                  2021-03-09 09:49:10.911  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: existsState(Sensor[counter])=true typeof (getState(Sensor[counter]).val)=number getState(Sensor[counter]).val=2.6
                  2021-03-09 09:49:10.912  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Tempval=2.6 TempUnit=V TypeOf=number
                  2021-03-09 09:49:10.912  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: 19 BatterieHomematic_30 found at hm-rpc.0.OEQ1676108.2.BATTERY_STATE Umax= 3 BattMinLimit=2.2 Val= 2.6 SensorProzent= 86.66666666666667
                  2021-03-09 09:49:10.917  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Reaching CheckDeadBatt()
                  2021-03-09 09:49:10.918  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ0708741 is possibly dead, searching for second check
                  2021-03-09 09:49:10.918  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ0708741 has second check, now checking
                  2021-03-09 09:49:10.918  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: z=0 Device hm-rpc.0.OEQ0708741 second check at  hm-rpc.0.OEQ0708741.1.STATE
                  2021-03-09 09:49:10.919  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: hm-rpc.0.OEQ0708741 is not dead at second checkpoint
                  2021-03-09 09:49:10.919  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ0708748 is possibly dead, searching for second check
                  2021-03-09 09:49:10.919  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ0708748 has second check, now checking
                  2021-03-09 09:49:10.919  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: z=1 Device hm-rpc.0.OEQ0708748 second check at  hm-rpc.0.OEQ0708748.1.STATE
                  2021-03-09 09:49:10.919  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: hm-rpc.0.OEQ0708748 is not dead at second checkpoint
                  2021-03-09 09:49:10.920  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ0709520 is possibly dead, searching for second check
                  2021-03-09 09:49:10.920  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ0709520 has second check, now checking
                  2021-03-09 09:49:10.920  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: z=2 Device hm-rpc.0.OEQ0709520 second check at  hm-rpc.0.OEQ0709520.1.STATE
                  2021-03-09 09:49:10.920  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: hm-rpc.0.OEQ0709520 is not dead at second checkpoint
                  2021-03-09 09:49:10.920  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ0709589 is possibly dead, searching for second check
                  2021-03-09 09:49:10.920  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ0709589 has second check, now checking
                  2021-03-09 09:49:10.921  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: z=3 Device hm-rpc.0.OEQ0709589 second check at  hm-rpc.0.OEQ0709589.1.STATE
                  2021-03-09 09:49:10.921  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: hm-rpc.0.OEQ0709589 is not dead at second checkpoint
                  2021-03-09 09:49:10.927  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ1424242 is possibly dead, searching for second check
                  2021-03-09 09:49:10.927  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ1424242 has second check, now checking
                  2021-03-09 09:49:10.927  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: z=5 Device hm-rpc.0.OEQ1424242 second check at  hm-rpc.0.OEQ1424242.1.STATE
                  2021-03-09 09:49:10.928  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: hm-rpc.0.OEQ1424242 is not dead at second checkpoint
                  2021-03-09 09:49:10.928  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ1424270 is possibly dead, searching for second check
                  2021-03-09 09:49:10.928  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ1424270 has second check, now checking
                  2021-03-09 09:49:10.928  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: z=6 Device hm-rpc.0.OEQ1424270 second check at  hm-rpc.0.OEQ1424270.1.STATE
                  2021-03-09 09:49:10.928  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Second check failed, hm-rpc.0.OEQ1424270 seems to be really dead
                  2021-03-09 09:49:10.929  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Jim...he's dead
                  2021-03-09 09:49:10.929  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Reaching Meldung()
                  2021-03-09 09:49:10.941  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Ausfall oder disconnect im Wohnzimmer Anbau bei Gerät Fenster_WZ_Anbau_2
                  2021-03-09 09:49:10.942  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ1424271 is possibly dead, searching for second check
                  2021-03-09 09:49:10.942  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ1424271 has second check, now checking
                  2021-03-09 09:49:10.942  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: z=7 Device hm-rpc.0.OEQ1424271 second check at  hm-rpc.0.OEQ1424271.1.STATE
                  2021-03-09 09:49:10.942  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: hm-rpc.0.OEQ1424271 is not dead at second checkpoint
                  2021-03-09 09:49:10.942  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ1424294 is possibly dead, searching for second check
                  2021-03-09 09:49:10.943  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Device hm-rpc.0.OEQ1424294 has second check, now checking
                  2021-03-09 09:49:10.943  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: z=8 Device hm-rpc.0.OEQ1424294 second check at  hm-rpc.0.OEQ1424294.1.STATE
                  2021-03-09 09:49:10.943  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: hm-rpc.0.OEQ1424294 is not dead at second checkpoint
                  2021-03-09 09:49:10.944  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Reaching MakeTable
                  2021-03-09 09:49:10.955  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Reaching CheckAllBatterys() found 20 Devices
                  2021-03-09 09:49:10.955  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Sensor[5] = ist ausgefallen oder disconnected
                  2021-03-09 09:49:10.956  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Reaching Meldung()
                  2021-03-09 09:49:10.965  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Ausfall oder disconnect im Wohnzimmer Anbau bei Gerät Fenster_WZ_Anbau_2
                  2021-03-09 09:49:10.965  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Reaching CheckAllBatterysOk - Lastmessage=Ausfall oder disconnect im Wohnzimmer Anbau bei Gerät Fenster_WZ_Anbau_2
                  2021-03-09 09:49:10.966  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Reaching CheckNextLowBatt()
                  2021-03-09 09:49:10.967  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Aktuell niedrigster Batteriestand (2.40V): Kinderzimmer OG3 bei Gerät HK_KZ_OG3
                  2021-03-09 09:49:10.967  - info: javascript.0 (2876) script.js.common.Batteriestatus.Überwachung_Batterie_HM: Reaching MakeTable
                  
                  P 1 Reply Last reply Reply Quote 0
                  • P
                    Pittini Developer @passuff last edited by

                    @passuff sagte in [Vorlage] Generische Batteriestandsüberwachung + Vis-ausgabe:

                    Verstanden, aber sollte nicht lfd 10 gelb sein?

                    Nein. Da isn kleiner Bug beim leer erkennen, ich frag da nach < ab, sollte aber <= sein. Werd ich im nächsten update fixen.

                    P Dominik F. 2 Replies Last reply Reply Quote 0
                    • P
                      passuff @Pittini last edited by

                      @pittini sagte in [Vorlage] Generische Batteriestandsüberwachung + Vis-ausgabe:

                      <

                      Habs entsprechend geändert:
                      5a4c279a-8069-47b3-a62a-f9d6b45647a0-image.png
                      Funktioniert jetzt - Danke Dir! 🙂

                      1 Reply Last reply Reply Quote 0
                      • S
                        Sneaker75 last edited by

                        @Pittini

                        Ich würde in das Skript gerne meine Lupusec-Sensoren einbinden. Die liefern allerdings keinen Spannungwert und auch keinen lowbat-Datenpunkt. Dort heißt der Datenpunkt battery_ok und liefert Okay zurück, wenn die Batterie noch gut ist. In der Tabelle zeigt er mir aber nur 1V als IST-Spannung an, wahrscheinlich weil Okay = 1 ist. Kann ich das Skript trotzdem dafür nutzen?

                        batterie1.png

                        batterie2.png

                        P 1 Reply Last reply Reply Quote 0
                        • P
                          Pittini Developer @Sneaker75 last edited by

                          @sneaker75 sagte in [Vorlage] Generische Batteriestandsüberwachung + Vis-ausgabe:

                          Kann ich das Skript trotzdem dafür nutzen?

                          Ein klares jaein 😉 . Den Fall gabs bisher noch nicht, also ist das nicht implementiert, sollte aber machbar sein. Noch einfacher wäre Alias Datenpunkte zu erstellen die das auf Boolsche lowbat true/false umbiegen.

                          S 1 Reply Last reply Reply Quote 0
                          • S
                            Sneaker75 @Pittini last edited by

                            @pittini Es geht um ca. 50 Sensoren, da ist vielleicht allgemein gesprochen das Implementieren einfacher, als mit alias-Datenpunkten zu arbeiten. Nur wenn Du mal Zeit finden solltest... 👼

                            P 1 Reply Last reply Reply Quote 0
                            • P
                              Pittini Developer @Sneaker75 last edited by

                              @sneaker75 sagte in [Vorlage] Generische Batteriestandsüberwachung + Vis-ausgabe:

                              @pittini Es geht um ca. 50 Sensoren, da ist vielleicht allgemein gesprochen das Implementieren einfacher, als mit alias-Datenpunkten zu arbeiten. Nur wenn Du mal Zeit finden solltest... 👼

                              50....na das is ja mal ne Ansage. Ich werd sehen was ich tun kann, gib mir mal nen Screenshot vom Raw eines dieser Datenpunkte.

                              S 2 Replies Last reply Reply Quote 1
                              • S
                                Sneaker75 @Pittini last edited by

                                @pittini

                                {
                                  "type": "state",
                                  "common": {
                                    "type": "number",
                                    "role": "value",
                                    "read": true,
                                    "write": false,
                                    "min": 0,
                                    "max": 1,
                                    "name": "KG Straße (Batterie)",
                                    "states": "0:Leer;1:Okay",
                                    "icon": "/icons/4.png",
                                    "custom": {
                                      "linkeddevices.0": {
                                        "enabled": true,
                                        "number_unit": "",
                                        "linkedId": "Batterie.ÖM Keller Straße",
                                        "name": "ÖM Keller Straße",
                                        "role": "",
                                        "mergeSettingsOnRestart": false,
                                        "expertSettings": false,
                                        "number_convertTo": "",
                                        "number_maxDecimal": "",
                                        "number_min": "",
                                        "number_max": "",
                                        "number_calculation": "",
                                        "number_calculation_readOnly": "",
                                        "number_to_boolean_condition": "",
                                        "number_to_boolean_value_true": "",
                                        "number_to_boolean_value_false": "",
                                        "number_to_string_condition": "",
                                        "number_to_duration_convert_seconds": "",
                                        "number_to_duration_format": "",
                                        "number_to_datetime_convert_seconds": "",
                                        "number_to_datetime_format": "",
                                        "number_to_multi_condition": "",
                                        "boolean_convertTo": "",
                                        "boolean_to_string_value_true": "",
                                        "boolean_to_string_value_false": "",
                                        "string_convertTo": "",
                                        "string_prefix": "",
                                        "string_suffix": "",
                                        "string_to_boolean_value_true": "",
                                        "string_to_boolean_value_false": "",
                                        "string_to_number_unit": "",
                                        "string_to_number_maxDecimal": "",
                                        "string_to_number_calculation": "",
                                        "string_to_number_calculation_readOnly": "",
                                        "string_to_duration_format": "",
                                        "string_to_datetime_parser": "",
                                        "string_to_datetime_format": ""
                                      }
                                    }
                                  },
                                  "native": {},
                                  "from": "system.adapter.lupusec.0",
                                  "user": "system.user.admin",
                                  "ts": 1583968824300,
                                  "_id": "lupusec.0.devices.RF:04a40010.battery_ok",
                                  "acl": {
                                    "object": 1636,
                                    "state": 1636,
                                    "owner": "system.user.admin",
                                    "ownerGroup": "system.group.administrator"
                                  }
                                }
                                
                                1 Reply Last reply Reply Quote 0
                                • N
                                  Nas007 last edited by Nas007

                                  Hallo,

                                  @Pittini erst mal vielen Dank für die tolle Arbeit.

                                  ich habe es soweit zum laufen bekommen, nur habe ich zwei Fragen:

                                  1. Wofür sind die Funktion DeadCheck?

                                  2. Ich Versuche die bsp. Visu einzufügen und bekomme immer folgende Meldung
                                    280f8aa7-d68b-4445-82ad-75b107d2e99c-grafik.png

                                  Mein Vorgehen:

                                  • Inhalt von hier kopiert: https://github.com/Pittini/iobroker-Batterienauswertung/blob/master/viswidgets.txt
                                  • in den Viseditor --> View importieren
                                  • obigen Part eingefügt
                                  • und dann kommt die Fehlermeldung

                                  Mit der Vis an sich kenne ich mich leider noch nicht gut aus. Wahrscheinlich ist das ein dummer Fehler.

                                  Achja ich nutze

                                  • Rasp 4
                                  • alle Adapter aktuell
                                  • Zigbee: Deconz
                                  • Node.js v12.21.0
                                  • NPM 6.14.11

                                  Vielen Dank schon mal und Gruß!

                                  S 1 Reply Last reply Reply Quote 0
                                  • S
                                    Sneaker75 @Nas007 last edited by Sneaker75

                                    @Nas007

                                    1. Damit kannst Du prüfen, ob ein Sensor tot ist. Wenn er ausfällt, kann er seinen Status nicht mehr senden, also nicht rufen „Hey, ich bin gerade ausgefallen“. Darum prüft der Datenpunkt, der für die Dead-Funktion gewählt wurde, wann er zuletzt aktualisiert wurde. Ist die definierte Zeitspanne überschritten, wird der Sensor als tot markiert.
                                    2. Nicht als Vis importieren, sondern als Widget.
                                    1 Reply Last reply Reply Quote 1
                                    • S
                                      Sneaker75 @Pittini last edited by

                                      @pittini said in [Vorlage] Generische Batteriestandsüberwachung + Vis-ausgabe:

                                      50....na das is ja mal ne Ansage. Ich werd sehen was ich tun kann, gib mir mal nen Screenshot vom Raw eines dieser Datenpunkte.

                                      Hey Pittini. Konntest Du Dir das schon ansehen?

                                      1 Reply Last reply Reply Quote 0
                                      • Dominik F.
                                        Dominik F. @Pittini last edited by

                                        @pittini

                                        Ich bekomme momentan eine Pushnachricht, dass bei dem im Bild unter Info gekennzeichneten Sensor die Batteriespannung unter Limit sei. Im Bild ist jedoch zu erkennen, dass der nicht unter Limit ist. Das was das Script anzeigt ist alles richtig, hab ich soweit überprüft, die Frage ist nun warum bekomm ich die Meldung das die Batteriespannung unter Limit ist?

                                        Unbenannt.PNG

                                        C 1 Reply Last reply Reply Quote 0
                                        • C
                                          canim @Dominik F. last edited by

                                          @dominik-f der Entwickler wollte sein Script noch Anpassen, das unterm Limit < erst die Meldung kommt. <=

                                          Dominik F. 1 Reply Last reply Reply Quote 0
                                          • Dominik F.
                                            Dominik F. @canim last edited by

                                            @canim

                                            Okay super. Ich hatte in Erinnerung das es ein Problem gab wenn U ist = U Limit ist und dann die Meldung fälschlicherweise kommt.

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            830
                                            Online

                                            31.7k
                                            Users

                                            79.9k
                                            Topics

                                            1.3m
                                            Posts

                                            javascript monitoring template
                                            81
                                            581
                                            109778
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo