    Test Adapter ZWave 2 v1.9.x

    This topic has been deleted. Only users with topic management privileges can see it.
    • eumats
      eumats @AlCalzone last edited by eumats

      @alcalzone

      Klar sehr gerne. Dann hier posten oder lieber einen issue?

      AlCalzone 1 Reply Last reply Reply Quote 0
      • AlCalzone
        AlCalzone Developer @eumats last edited by

        @eumats Ruhig hier

        eumats 1 Reply Last reply Reply Quote 0
        • eumats
          eumats @AlCalzone last edited by eumats

          @AlCalzone

          Hier die Dateien. Es handelt sich im die Nodes 005 und 005. Danke..

          zwave-18410.log
          cc14663e.json
          cc14663e.values.jsonl

          AlCalzone 1 Reply Last reply Reply Quote 0
          • AlCalzone
            AlCalzone Developer @eumats last edited by

            @eumats 5 und nochmal 5? 😉

            eumats 1 Reply Last reply Reply Quote 0
            • AlCalzone
              AlCalzone Developer last edited by

              Das Log scheint mir nicht besonders vollständig, aber ich hab da ne Idee:

              cannot reply to NonceGet because no network key was configured!
              

              Du hast verschlüsselt eingebundene Geräte, aber den Netzwerkschlüssel nicht aus dem alten Adapter übernommen.

              eumats 1 Reply Last reply Reply Quote 0
              • eumats
                eumats @AlCalzone last edited by

                @alcalzone

                Upsi. 5 und 6... 😁

                1 Reply Last reply Reply Quote 0
                • eumats
                  eumats @AlCalzone last edited by eumats

                  @alcalzone

                  Eigentlich habe ich damals alle Geräte unverschlüsselt eingebunden. Ich habe es mal versucht um verschlüsseln, aber die Geräte ließen sich dann nicht koppeln.

                  Ich schaue aber morgen noch mal...

                  Edit: Was meinst Du mit das Log war nicht vollständig? Der Adapter lief da 10min. War das zu kurz?
                  Die die betreffenden Geräte wurden ja erkannt. Daher dachte ich es reicht aus.

                  eumats AlCalzone 2 Replies Last reply Reply Quote 0
                  • eumats
                    eumats @eumats last edited by

                    Es hat mir doch keine Ruhe gelassen und ich habe es gerade noch mal versucht. Ich hatte anscheinend doch genau die beiden Geräte damals verschlüsselt eingebunden. ☺️
                    Nachdem ich den Netzwerkschlüssel vom zwave Adapter im zwave 2 eingetragen und bei den beiden Geräten „erneut interviewen“ betätigt habe, wurde die Datenpunkte korrekt erzeugt.
                    Und sie lassen sich nun auch schalten...

                    Vielen Dank für Deine Hilfe!

                    1 Reply Last reply Reply Quote 0
                    • AlCalzone
                      AlCalzone Developer @eumats last edited by AlCalzone

                      @eumats Ich hatte dich um ein erneutes Interview gebeten - das ist da nicht zu sehen 🙂
                      c4969d26-bd54-4e44-a024-e346ebe16554-grafik.png

                      In Version 1.9 passiert beim Start fast nichts mehr, den normalen Start kann ich daher nicht zum Troubleshooting nutzen.

                      Wenn das Gerät aber nach einem Code zum Verschlüsseln fragt, bin ich sicher, dass es auch verschlüsselt eingebunden wurde.


                      Edit: Ist egal, du hast es ja jetzt 🙂

                      1 Reply Last reply Reply Quote 1
                      • _nico
                        _nico last edited by _nico

                        @AlCalzone Nach dem Leeren des Caches und den Interviews werden wieder die Datenpunkte Binary_Sensor.motion und Binary_Sensor.door_window benutzt. Danke für deine Hilfestellung!

                        Wie kann ich vermeiden, dass so etwas wieder passiert? Hast du eine Idee warum es passiert ist?

                        Viele Grüße

                        AlCalzone 1 Reply Last reply Reply Quote 0
                        • AlCalzone
                          AlCalzone Developer @_nico last edited by

                          @_nico Ich hab ehrlich gesagt keine Ahnung wie das passieren konnte.

                          1 Reply Last reply Reply Quote 0
                          • P
                            peppino last edited by

                            Hallo,

                            Nach länger Abstinenz habe ich wieder mal die neueste Zwave2 Version probiert und ich muss sagen ich bin begeistert.

                            Ich habe bei meinen ~20 Zwave Geräten nur bei einem Teilnehmer ein Problem.
                            Mein Fibaro FGR223 den ich Secure eigebunden habe liefert keine Meter Werte, weder kWh noch W.

                            33f38db6-e0e1-4aab-a8a6-578b726be761-grafik.png

                            Cache gelöscht und neu interviewt keine Änderung.

                            Joe

                            H 1 Reply Last reply Reply Quote 0
                            • AlCalzone
                              AlCalzone Developer last edited by

                              @peppino Log bitte:
                              https://github.com/AlCalzone/ioBroker.zwave2/blob/master/docs/de/bei-problemen.md#notwendige-informationen-für-ein-issue

                              P 1 Reply Last reply Reply Quote 0
                              • P
                                peppino @AlCalzone last edited by

                                @alcalzone

                                Node 20 ist der Übeltäter.

                                zwave-11725.log d9e9d0ab.json d9e9d0ab.values.jsonl

                                1 Reply Last reply Reply Quote 0
                                • H
                                  Harry94 @peppino last edited by

                                  @peppino Ich hatte ein Ähnliches Problem beim Umstieg vom "alten" Z-wave Adapter. Da hat einmal neu anlernen geholfen.

                                  P 1 Reply Last reply Reply Quote -1
                                  • P
                                    peppino @Harry94 last edited by

                                    @harry94
                                    @alcalzone

                                    Leider bin ich an der Exclusion des FGR223 gescheitert, weder der b-button noch der Taster an S1 wollten ihn zur Exclusion überreden. Nicht desto trotz hatte ich trotzdem einen Erfolg, während meinen Versuchen hatte ich mehrmals den FGR223 vom Netz genommen, das hat ihm anscheinend jetzt doch dazu überredet "Meter" Werte zu senden. 😊

                                    AlCalzone 1 Reply Last reply Reply Quote 0
                                    • AlCalzone
                                      AlCalzone Developer @peppino last edited by

                                      @peppino Laut Log hat der Node nicht auf die Abfrage geantwortet, welche verschlüsselten Befehle er unterstützt - in Folge dessen wurde er als nicht verschlüsselt eingestuft - und dann ging nix mehr, weil er ja verschlüsselt ist.
                                      Müsste man eigentlich am fehlenden 🔒 in der Geräteliste sehen.

                                      P 1 Reply Last reply Reply Quote 0
                                      • P
                                        peppino @AlCalzone last edited by

                                        @alcalzone
                                        Das Schlosssymbol war vorhanden und mit targetvalue konnte ich ihn auch bedienen

                                        AlCalzone 1 Reply Last reply Reply Quote 0
                                        • AlCalzone
                                          AlCalzone Developer @peppino last edited by

                                          @peppino Stimmt - ich seh grad, dass du nochmal interviewt hast - dann ging alles außer den Reports.

                                          1 Reply Last reply Reply Quote 0
                                          • ?
                                            A Former User last edited by A Former User

                                            Ich habe hier mehrere Jalousien an RollerShutter 2, mir fehlt bei den Lamellen die Aktuelle Positionmeldung.

                                            sowas in der Art "venetianBlindsTiltPosition"

                                            In FHEM stand die aktuelle Position von den Lamellen und vom Rollo in einem Register hintereinander.

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            872
                                            Online

                                            31.8k
                                            Users

                                            79.9k
                                            Topics

                                            1.3m
                                            Posts

                                            adapter test z-wave zwave
                                            12
                                            87
                                            6895
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo