      Scrounger Developer @ub.privat last edited by

      @ub-privat sagte in Material Design Widgets: Value Widget:

      @scrounger

      ...da haben wir uns falsch verstanden.

      😉

      Mit dem value Widget geht das noch nicht, muss ich noch implementieren.
      Das kannst mit Binding realisieren, so in der Art:

      {a:idDatenpunkt; a === "Cooking.Oven.Program.HeatingMode.SlowCook" ? "Sanftgaren" : a === "Cooking.Oven.Program.HeatingMode.HotAir" ? "4D Heißluft" : "coolStart-Funktion"}
      
      ub.privat 1 Reply Last reply Reply Quote 0
      • sigi234
        sigi234 Forum Testing Most Active @ub.privat last edited by sigi234

        @ub-privat sagte in Material Design Widgets: Value Widget:

        Sigi234 - in deiner VIS habe ich auch gesehne, dass du mit dem HomeConnect-Adapter arbeitest und entrsprechnd die Geräte visualisierst. Hättest du ggf. einen Tipp?

        Ja, leider geht das nicht. Am Besten wäre es wenn es im Adapter als DP zur Verfügung stehen würde.

        @arteck

        https://forum.iobroker.net/topic/16446/test-adapter-homeconnect-bsh-home-connect-v0-0-x

        liv-in-sky 1 Reply Last reply Reply Quote 0
        • ub.privat
          ub.privat @Scrounger last edited by

          @scrounger

          ...das mit dem Binding ist einleuchtend!
          Nur mit welchem Widget bringe ich das Binding zur Anwendung?
          Ein einfaches basic-html oder basic-string?

          Scrounger 1 Reply Last reply Reply Quote 0
          • Scrounger
            Scrounger Developer @ub.privat last edited by Scrounger

            @ub-privat
            Ja zb. Kannst dafür viele verwenden, auch das value Widget, musst dann das Binding bei text überschreiben eintragen

            ub.privat 1 Reply Last reply Reply Quote 0
            • ub.privat
              ub.privat @Scrounger last edited by

              @scrounger

              na dann nehem ich doch das Value.
              Ich probier es aus... scheint zu funktionieren!

              DANKE. Das schöne daran ist, dass ich wieder etwas gelernt habe!

              1 Reply Last reply Reply Quote 0
              • ub.privat
                ub.privat last edited by

                @scrounger

                Hallo, leider muss ich nochmals anfragen. Die egestrige Euphorie wurde heute leider wieder gedämpft.
                Was habe ich gemacht?

                Zuerst habe ich mir von dem zu visualiserenden DP die RAW-Daten geholt:

                21173bd2-ccf8-4e67-bca4-efc38398077c-grafik.png

                "states": {
                      "BSH.Common.EnumType.OperationState.Inactive": "Inactive",
                      "BSH.Common.EnumType.OperationState.Ready": "Ready",
                      "BSH.Common.EnumType.OperationState.Run": "Run",
                      "BSH.Common.EnumType.OperationState.Finished": "Finished",
                      "BSH.Common.EnumType.OperationState.Pause": "Pause"
                

                Diese habe ich dann in das entsprechende Binding gepackt:

                {a:homeconnect.0.SIEMENS-HS858GXB6-68A40E060A0C.status.BSH_Common_Status_OperationState; a=== "BSH.Common.EnumType.OperationState.Inactive": ? "Inaktiv" : a=== "BSH.Common.EnumType.OperationState.Ready": ? "Bereit" : a=== "BSH.Common.EnumType.OperationState.Run": ? "Programm läuft" : a=== "BSH.Common.EnumType.OperationState.Finished": ? "Programm beendet" : a === "BSH.Common.EnumType.OperationState.Pause": ? "Pause"}
                

                ... und in Text überschreiben eingefügt:

                4d39f560-d914-49f9-8272-d6fd7b8d6b85-grafik.png

                Leider wird in der aktiven VIS nichts angezeigt...

                93a7860f-0af6-44c2-bdb9-442aaa3a5757-grafik.png
                Habe nun so ziemlich jedes Programm ausprobiert und sicher festgestellt, dass der DP mit dem entsprechenden Wert belegt ist.

                So richtig will die Anzeige nicht passen.
                Kann noch ein "Tippfehler" die Ursache sien?

                Scrounger 1 Reply Last reply Reply Quote 0
                • Scrounger
                  Scrounger Developer @ub.privat last edited by

                  @ub-privat
                  : ? Ist falsch, Vergleich es mit meinem Beispiel

                  ub.privat 1 Reply Last reply Reply Quote 0
                  • ub.privat
                    ub.privat @Scrounger last edited by

                    @scrounger
                    @sigi234

                    ich könnte verzweifeln...

                    Dein Beispiel:

                    {a:idDatenpunkt; a === "Cooking.Oven.Program.HeatingMode.SlowCook" ? "Sanftgaren" : a === "Cooking.Oven.Program.HeatingMode.HotAir" ? "4D Heißluft" : "coolStart-Funktion"} 
                    

                    Meine angepasstes Binding:

                    {a:homeconnect.0.SIEMENS-HS858GXB6-68A40E060A0C.status.BSH_Common_Status_OperationState; a === "BSH.Common.EnumType.OperationState.Inactive" ? "Inactive : a === "BSH.Common.EnumType.OperationState.Ready" ? "Ready" : a === "BSH.Common.EnumType.OperationState.Run" ? "Run" : a === "BSH.Common.EnumType.OperationState.Finished" ? "Finished" : a === "BSH.Common.EnumType.OperationState.Pause" ? "Pause"}
                    

                    Zwischen jedem Doppelpunkt steht die Ereignisabfrage und die "" beschreiben das anzuzeogende Ergebnis.
                    Ich bin jeden Punkt, Doppelpunkt, Leerzeichen durchgegangen!
                    Leider ohne Erfolg.

                    baeb9a6d-0cd5-474a-aff2-c575d5336715-grafik.png

                    Hier der DP:
                    5910c3a1-6183-4f4f-92cc-c4f9afc5c397-grafik.png
                    Somit müßte in der VIS 'Inactive' stehen, tut es aber nicht, stattdessen steht eine Null!?

                    2eed322c-212b-4995-a9f3-5e9930913590-grafik.png

                    Woher kommt die NULL und wonach muss ich noch schauen?

                    Scrounger 1 Reply Last reply Reply Quote 0
                    • Scrounger
                      Scrounger Developer @ub.privat last edited by

                      @ub-privat
                      Hinter inactive fehlt "

                      ub.privat 1 Reply Last reply Reply Quote 0
                      • ub.privat
                        ub.privat @Scrounger last edited by

                        @scrounger

                        Du hast recht, es fehlte das Ausführungszeichen "...

                        {a:homeconnect.0.SIEMENS-HS858GXB6-68A40E060A0C.status.BSH_Common_Status_OperationState; a === "BSH.Common.EnumType.OperationState.Inactive" ? "Inactive" : a === "BSH.Common.EnumType.OperationState.Ready" ? "Ready" : a === "BSH.Common.EnumType.OperationState.Run" ? "Run" : a === "BSH.Common.EnumType.OperationState.Finished" ? "Finished" : a === "BSH.Common.EnumType.OperationState.Pause" ? "Pause"}
                        

                        es ändert aber nichts am Ergebnis!
                        345802dd-c4d1-4b5e-8876-e152bdb05612-grafik.png

                        So langsam gebe ich auf...

                        Du hattest geschrieben: "😉 Mit dem value Widget geht das noch nicht, muss ich noch implementieren.", , dass du diese Art der Abfrage mit in das Widget einbauen möchtest. Dann werde ich wohl warten. Egal welches Widget ich verwende, dass Bindig ist ja entscheidend.

                        Scrounger 1 Reply Last reply Reply Quote 0
                        • liv-in-sky
                          liv-in-sky @sigi234 last edited by

                          @sigi234
                          hi, habe es mal in einem html widget gemacht - da sieht es so aus - habe eure datenpunkte mal nachgebaut - sowas habe ich nicht

                          datenpunkt raw:

                          {
                           "from": "system.adapter.admin.0",
                           "user": "system.user.admin",
                           "ts": 1616765507789,
                           "common": {
                             "name": "wertelister_Sigi",
                             "role": "",
                             "type": "string",
                             "desc": "Manuell erzeugt",
                             "min": 0,
                             "max": 5,
                             "def": 0,
                             "read": true,
                             "write": true,
                             "states": {
                               "Cooking.Oven.Program.HeatingMode.SlowCook": "Sanftgaren",
                               "Cooking.Oven.Program.HeatingMode.HotAir": "4D Heißluft",
                               "Cooking.Oven.Program.HeatingMode.TopBottomHeating": "Ober-/ Unterhitze",
                               "Cooking.Oven.Program.HeatingMode.HotAirEco": "Heißluft eco",
                               "Cooking.Oven.Program.HeatingMode.TopBottomHeatingEco": "Ober-/ Unterhitze eco",
                               "Cooking.Oven.Program.HeatingMode.HotAirGrilling": "Umluftgrillen",
                               "Cooking.Oven.Program.HeatingMode.PizzaSetting": "Pizzastufe",
                               "Cooking.Oven.Program.HeatingMode.IntensiveHeat": "Intensivhitze",
                               "Cooking.Oven.Program.HeatingMode.BottomHeating": "Unterhitze",
                               "Cooking.Oven.Program.HeatingMode.Desiccation": "Dörren",
                               "Cooking.Oven.Program.HeatingMode.PreheatOvenware": "Geschirr vorwärmen",
                               "Cooking.Oven.Program.HeatingMode.KeepWarm": "Warmhalten",
                               "Cooking.Oven.Program.HeatingMode.FrozenHeatupSpecial": "coolStart-Funktion"
                             }
                           },
                           "native": {},
                           "acl": {
                             "object": 1636,
                             "owner": "system.user.admin",
                             "ownerGroup": "system.group.administrator",
                             "state": 1636
                           },
                           "_id": "controll-own.0.AAATEST.wertelister_Sigi",
                           "type": "state"
                          }
                          

                          FORMEL in html widget:

                          {val:controll-own.0.AAATEST.wertelister_Sigi; val== "Cooking.Oven.Program.HeatingMode.SlowCook" ? "SlowCook" : val=="Cooking.Oven.Program.HeatingMode.HotAir" ? "HotAir" : val=="Cooking.Oven.Program.HeatingMode.TopBottomHeating" ? "TopBottomHeating" : val=="Cooking.Oven.Program.HeatingMode.HotAirEco" ? "HotAirEco" : val == "Cooking.Oven.Program.HeatingMode.HotAirGrilling" ? "HotAirGrilling" : "no-no" } 
                          

                          vis:

                          AApossis (31).gif

                          checke nur dieersten einträge- wenn dann einer nicht dabei ist, wird no-no angezeigt - dass muss am ende auch stehen, sonst ist die formel nicht vollständig - auch wenn alle einträge abgefragt werden

                          ein value widget finde ich nicht - wie heißt das genau - ist doch im material design widget - finde ich nicht

                          1 Reply Last reply Reply Quote 0
                          • liv-in-sky
                            liv-in-sky last edited by

                            @sigi234

                            mittlerweile habe ich das value widget

                            da geht es auch

                            AApossis (32).gif

                            selbe formel - selber datenpunkt

                            Image 1.png

                            sigi234 1 Reply Last reply Reply Quote 0
                            • sigi234
                              sigi234 Forum Testing Most Active @liv-in-sky last edited by

                              @liv-in-sky

                              Geht nicht, mein Original RAW:

                              {
                                "from": "system.adapter.homeconnect.0",
                                "user": "system.user.admin",
                                "ts": 1616770922094,
                                "common": {
                                  "name": "Betriebsstatus",
                                  "type": "mixed",
                                  "role": "indicator",
                                  "unit": "",
                                  "write": true,
                                  "read": true,
                                  "states": {
                                    "BSH.Common.EnumType.OperationState.Inactive": "Inactive",
                                    "BSH.Common.EnumType.OperationState.Ready": "Ready",
                                    "BSH.Common.EnumType.OperationState.Run": "Run",
                                    "BSH.Common.EnumType.OperationState.Finished": "Finished"
                                  }
                                },
                                "native": {},
                                "acl": {
                                  "object": 1636,
                                  "owner": "system.user.admin",
                                  "ownerGroup": "system.group.administrator",
                                  "state": 1636
                                },
                                "_id": "homeconnect.0.401010522278007458.status.BSH_Common_Status_OperationState",
                                "ty
                              
                              liv-in-sky 1 Reply Last reply Reply Quote 0
                              • liv-in-sky
                                liv-in-sky @sigi234 last edited by

                                @sigi234 zeig mal die formel

                                sigi234 1 Reply Last reply Reply Quote 0
                                • sigi234
                                  sigi234 Forum Testing Most Active @liv-in-sky last edited by sigi234

                                  @liv-in-sky sagte in Material Design Widgets: Value Widget:

                                  @sigi234 zeig mal die formel

                                  {a:homeconnect.0.401010522278007458.status.BSH_Common_Status_OperationState; a === "BSH.Common.EnumType.OperationState.Inactive" ? "aus" : a === "BSH.Common.EnumType.OperationState.Ready" ? "Ready" : a === "BSH.Common.EnumType.OperationState.Run" ? "Run" : a === "BSH.Common.EnumType.OperationState.Finished" ? "Finished"}
                                  

                                  Im Wert sind Klammern?

                                  Screenshot (3521).png

                                  liv-in-sky 2 Replies Last reply Reply Quote 0
                                  • Scrounger
                                    Scrounger Developer @ub.privat last edited by Scrounger

                                    @ub-privat, @sigi234
                                    Das Binding ist auch nicht korrekt, so auf die schnelle am Ende fehlt noch Else Bedienung also : xxx

                                    Schau dir das bei @liv-in-sky an da ist es korrekt.
                                    Grundsätzlich kann ich dir empfehlen Bau das Mal Schritt für Schritt auf, also erste Bedienung, testen, dann zweite Bedienung rein, testen usw

                                    1 Reply Last reply Reply Quote 1
                                    • liv-in-sky
                                      liv-in-sky @sigi234 last edited by liv-in-sky

                                      @sigi234

                                      teste mal:

                                      {val:homeconnect.0.401010522278007458.status.BSH_Common_Status_OperationState; val== "BSH.Common.EnumType.OperationState.Inactive" ? "aus" : val=="BSH.Common.EnumType.OperationState.Ready" ? "Ready" : val=="BSH.Common.EnumType.OperationState.Run" ? "Run" : val=="BSH.Common.EnumType.OperationState.Finished" ? "Finished" : "no-no" } 
                                      
                                      1 Reply Last reply Reply Quote 0
                                      • liv-in-sky
                                        liv-in-sky @sigi234 last edited by

                                        @sigi234

                                        sorry - diesmal hatte ich einen fehler drin

                                        {val:homeconnect.0.401010522278007458.status.BSH_Common_Status_OperationState; val== "BSH.Common.EnumType.OperationState.Inactive" ? "aus" : val=="BSH.Common.EnumType.OperationState.Ready" ? "Ready" : val=="BSH.Common.EnumType.OperationState.Run" ? "Run" : val=="BSH.Common.EnumType.OperationState.Finished" ? "Finished" :  "no-no" } 
                                        
                                        sigi234 1 Reply Last reply Reply Quote 1
                                        • sigi234
                                          sigi234 Forum Testing Most Active @liv-in-sky last edited by sigi234

                                          @liv-in-sky sagte in Material Design Widgets: Value Widget:

                                          @sigi234

                                          sorry - diesmal hatte ich einen fehler drin

                                          Jupp, es kommt Run 👍

                                          Ich sehe auf den 1.Blick keinen Unterschied

                                          liv-in-sky 1 Reply Last reply Reply Quote 0
                                          • liv-in-sky
                                            liv-in-sky @sigi234 last edited by liv-in-sky

                                            @sigi234 dann nutz den zweiten - === ist jetzt ==
                                            und am ende fehlte : no-no - sonst ist die formel nicht richtig

                                            sigi234 1 Reply Last reply Reply Quote 1
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            1.2k
                                            Online

                                            31.7k
                                            Users

                                            79.7k
                                            Topics

                                            1.3m
                                            Posts

                                            vis
                                            16
                                            76
                                            6838
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo