    4. Wasserzähler (Funk 868) auslesen.

    NEWS

    • [erledigt] 15. 05. Wartungsarbeiten am ioBroker Forum

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    Wasserzähler (Funk 868) auslesen.

    This topic has been deleted. Only users with topic management privileges can see it.
    • hg6806
      hg6806 Most Active last edited by hg6806

      So, habe den Pi nochmal neu gestartet und bekomme nun folgendes:

      pi@raspberrypi:~ $ systemctl status wmbusmeters
      ● wmbusmeters.service - "wmbusmeters service"
         Loaded: loaded (/lib/systemd/system/wmbusmeters.service; enabled; vendor preset: enabled)
         Active: active (running) since Sat 2021-06-19 07:56:18 CEST; 6min ago
           Docs: https://github.com/weetmuts/wmbusmeters
                 man:wmbusmeters(1)
        Process: 538 ExecStartPre=/bin/mkdir -p /var/log/wmbusmeters/meter_readings (code=exited, status=0/SUCCESS)
        Process: 549 ExecStartPre=/bin/chown -R wmbusmeters:wmbusmeters /var/log/wmbusmeters (code=exited, status=0/SUCCESS)
        Process: 562 ExecStartPre=/bin/mkdir -p /run/wmbusmeters (code=exited, status=0/SUCCESS)
        Process: 564 ExecStartPre=/bin/chown -R wmbusmeters:wmbusmeters /run/wmbusmeters (code=exited, status=0/SUCCESS)
        Process: 565 ExecStart=/usr/sbin/wmbusmetersd /run/wmbusmeters/wmbusmeters.pid (code=exited, status=0/SUCCESS)
       Main PID: 583 (wmbusmetersd)
          Tasks: 3 (limit: 4915)
         CGroup: /system.slice/wmbusmeters.service
                 └─583 /usr/sbin/wmbusmetersd /run/wmbusmeters/wmbusmeters.pid
      
      Jun 19 07:56:18 raspberrypi systemd[1]: Starting "wmbusmeters service"...
      Jun 19 07:56:18 raspberrypi wmbusmetersd[565]: (wmbusmeters) started /run/wmbusmeters/wmbusmeters.pid
      Jun 19 07:56:18 raspberrypi systemd[1]: Started "wmbusmeters service".
      pi@raspberrypi:~ $
      
      
      

      Sieht doch eigentlich gut aus und bin mal gespannt ob Daten kommen.

      1 Reply Last reply Reply Quote 1
      • M
        Michi_Pi @hg6806 last edited by

        @hg6806 sagte in Wasserzähler (Funk 868) auslesen.:

        Woher kommt dieses xxx.save?

        Keine Ahnung woher diese kommt. Ich habe diese nicht.

        Wie @Thomas-Braun schon schrieb, füg deinen Username zu der Gruppe wmbusmeters hinzu.

        sudo usermod -a -G wmbusmeters deineUsername
        

        Normal macht er das ja bei der Installation mit sudo make install

        1 Reply Last reply Reply Quote 0
        • hg6806
          hg6806 Most Active last edited by

          Läuft!!!

          Danke nochmal für den Support!

          Ich schreibe für mich mal eine Anleitung um den iPerl Zähler in ioBroker einzubinden.

          1 Reply Last reply Reply Quote 1
          • hg6806
            hg6806 Most Active last edited by hg6806

            Leute, sorry, ich muss nochmal nerven.

            System, wieder neu aufgesetzt (endlich wieder auf eine SSD), alles genau nach Anleitung gemacht bzw. meine Settings.
            Leider kommen wieder keine Daten. Junge Junge, ist das zickig!

            Wieso sind keine meters konfiguriert?

            pi@raspberrypi:~ $ sudo systemctl stop wmbusmeters.service
            pi@raspberrypi:~ $ wmbusmeters auto:t1
            Started auto cul on /dev/ttyACM0 listening on t1
            No meters configured. Printing id:s of all telegrams heard!
            
            

            Config ist genau wie beim letzten Mal!
            Und ich habe seit dem eine sehr hohe CPU Auslastung.

            Und Status sieht auch gut aus:

            pi@raspberrypi:~ $ systemctl status wmbusmeters
            ● wmbusmeters.service - "wmbusmeters service"
               Loaded: loaded (/lib/systemd/system/wmbusmeters.service; enabled; vendor preset: enabled)
               Active: inactive (dead) since Mon 2021-06-21 12:30:05 CEST; 16min ago
                 Docs: https://github.com/weetmuts/wmbusmeters
                       man:wmbusmeters(1)
              Process: 541 ExecStartPre=/bin/mkdir -p /var/log/wmbusmeters/meter_readings (code=exited, status=0/SUCCESS)
              Process: 555 ExecStartPre=/bin/chown -R wmbusmeters:wmbusmeters /var/log/wmbusmeters (code=exited, status=0/SUCCESS)
              Process: 563 ExecStartPre=/bin/mkdir -p /run/wmbusmeters (code=exited, status=0/SUCCESS)
              Process: 571 ExecStartPre=/bin/chown -R wmbusmeters:wmbusmeters /run/wmbusmeters (code=exited, status=0/SUCCESS)
              Process: 576 ExecStart=/usr/sbin/wmbusmetersd /run/wmbusmeters/wmbusmeters.pid (code=exited, status=0/SUCCESS)
             Main PID: 578 (code=exited, status=0/SUCCESS)
            
            Jun 20 21:56:17 raspberrypi systemd[1]: Starting "wmbusmeters service"...
            Jun 20 21:56:17 raspberrypi wmbusmetersd[576]: (wmbusmeters) started /run/wmbusmeters/wmbusmeters.pid
            Jun 20 21:56:17 raspberrypi systemd[1]: Started "wmbusmeters service".
            Jun 21 12:30:05 raspberrypi systemd[1]: Stopping "wmbusmeters service"...
            Jun 21 12:30:05 raspberrypi systemd[1]: wmbusmeters.service: Succeeded.
            Jun 21 12:30:05 raspberrypi systemd[1]: Stopped "wmbusmeters service".
            
            
            Thomas Braun M 2 Replies Last reply Reply Quote 0
            • Thomas Braun
              Thomas Braun Most Active @hg6806 last edited by

              @hg6806 sagte in Wasserzähler (Funk 868) auslesen.:

              Active: inactive

              Der Service läuft nicht.

              1 Reply Last reply Reply Quote 0
              • M
                Michi_Pi @hg6806 last edited by

                @hg6806 wie gehst du vor bei der Installation?

                Hier mal mein Weg wenn ich neu installiere.

                sudo apt install librtlsdr-dev
                git clone https://github.com/weetmuts/wmbusmeters.git
                cd wmbusmeters
                make && make test
                sudo make install
                sudo systemctl daemon-reload
                

                Wenn ich die beiden Config´s bereits erstellt hatte (die speichere ich mir lokal nochmal ab) dann muss ich nur noch den Inhalt in diese beiden Dateien kopieren.

                sudo nano /etc/wmbusmeters.conf 
                sudo nano /etc/wmbusmeters.d/meinWasserzaehler
                

                Danach nur noch den Dienst starten und nicht noch wmbusmeters auto:t1 ausführen

                sudo systemctl start wmbusmeters
                sudo systemctl enable wmbusmeters
                
                hg6806 1 Reply Last reply Reply Quote 0
                • hg6806
                  hg6806 Most Active @Michi_Pi last edited by hg6806

                  @michi_pi

                  Keine Ahnung wo es schon wieder hängt.
                  Ich hatte wmbusmeters erst deinstalliert über:

                  sudo systemctl stop wmbusmeters
                  cd wmbusmeters
                  sudo make uninstall
                  

                  dann:

                  pi@raspberrypi:~ $ git clone https://github.com/weetmuts/wmbusmeters.git
                  fatal: Zielpfad 'wmbusmeters' existiert bereits und ist kein leeres Verzeichnis.
                  pi@raspberrypi:~ $ sudo git clone https://github.com/weetmuts/wmbusmeters.git
                  fatal: Zielpfad 'wmbusmeters' existiert bereits und ist kein leeres Verzeichnis.
                  pi@raspberrypi:~ $ cd wmbusmeters
                  pi@raspberrypi:~/wmbusmeters $ make && make test
                  Building 1.3.0-23-g08b9153
                  Building 1.3.0-23-g08b9153
                  OK: test internals
                  OK: Test C1 meters
                  OK json: Test T1 meters
                  OK fields: Test T1 meters
                  OK json: Test S1 meters
                  OK fields: Test S1 meters
                  OK: Test meter with unknown driver
                  OK json: Test naughty non-compliant apator162 meters
                  OK fields: Test naughty non-compliant apator162 meters
                  OK json: Test Izars meters
                  OK: Test listen to all izars
                  OK: Test aes encrypted telegrams
                  OK: Test that failed decryption warning only prints once.
                  OK: Test shell invocation
                  OK: Test shell in config file
                  OK: Test that normal meterfiles are written
                  OK: Test that meterfiles with name-id are written
                  OK: Test that meterfiles with id are written
                  OK: Test that meterfiles with timestamps are written
                  OK: Test that meterfiles with timestamps are written
                  OK: Test normal config files with C1 meters
                  OK: Test logfile
                  OK: Test single meter conf file matches any id
                  OK: Test listen and print any meter heard in logfile
                  OK: Test listen and print any meter heard on stdout
                  OK: Test detection of drivers for all telegrams
                  OK: Test listen to wildcard * id
                  OK: Test listen to wildcard suffix 8856* id
                  OK: Test listen to two comma separted ids
                  OK: Test listen to three comma separted ids
                  OK: Test listen with negated ids
                  OK: Test listen with wrong driver and wildcard
                  OK: Test conversions of units
                  OK: Test selected fields
                  OK: Test oneshot
                  OK: Test wrong keys
                  OK: Test config4 with added conversions
                  OK: Test that listen to t1+c1 works with meters transmitting using t1+c1
                  OK: Test that listen to t1+c1 works with meters transmitting using t1+c1
                  OK: Test that setting supercom587 to c1 fails
                  OK: Test additional json from cmdline
                  OK: Test additional shell envs from cmdline
                  OK: Test additional json from wmbusmeters.conf and from meter file
                  OK: Test rtlwmbus starting background script to produce telegrams
                  OK: Reading binary telegram from stdin
                  OK: Reading binary telegram from file
                  OK: Reading rtlwmbus formatted telegrams from stdin
                  OK: Reading rtlwmbus formatted telegrams from file
                  OK: Reading rtl433 formatted telegrams from stdin
                  OK: Reading rtl433 formatted telegrams from file
                  OK: Test ok serial rawtty telegram on stdin
                  OK: Test bad serial rawtty telegram with interspersed noise, on stdin
                  OK: Test duplicates are ignored
                  OK: Test duplicates are left alone
                  OK: Test match on dll id
                  OK: Test match on tpl id
                  OK: Test log timestamps
                  Slower tests...
                  OK: reading all stdin before closing down
                  RUNNING Test alarms ...
                  STDERR---------------------------------
                  [ALARM DeviceInactivity] 4 seconds of inactivity resetting simulations/simulatio                                                                                                             n_alarm.txt simulation (timeout 4s expected mon-sun(00-23) now 2021-06-22 22:17)
                  (wmbus) successfully reset wmbus device
                  STDOUT---------------------------------
                  TMP/OUTPUT-----------------------------
                  METER =={"media":"cold water","meter":"multical21","name":"Water","id":"76348799                                                                                                             ","total_m3":6.408,"target_m3":6.408,"max_flow_m3h":0,"flow_temperature_c":127,"                                                                                                             external_temperature_c":19,"current_status":"DRY","time_dry":"22-31 days","time_                                                                                                             reversed":"","time_leaking":"","time_bursting":"","timestamp":"2021-06-22T20:17:                                                                                                             46Z"}==
                  METER =={"media":"cold water","meter":"multical21","name":"Water","id":"76348799                                                                                                             ","total_m3":6.408,"target_m3":6.408,"max_flow_m3h":0,"flow_temperature_c":127,"                                                                                                             external_temperature_c":19,"current_status":"DRY","time_dry":"22-31 days","time_                                                                                                             reversed":"","time_leaking":"","time_bursting":"","timestamp":"2021-06-22T20:17:                                                                                                             52Z"}==
                  TMP/ALARM------------------------------
                  ALARM_SHELL DeviceInactivity [ALARM DeviceInactivity] 4 seconds of inactivity re                                                                                                             setting simulations/simulation_alarm.txt simulation (timeout 4s expected mon-sun                                                                                                             (00-23) now 2021-06-22 22:17)
                  ---------------------------------------
                  OK: Test alarms
                  All tests ok!
                  pi@raspberrypi:~/wmbusmeters $ sudo nano /etc/wmbusmeters.conf
                  pi@raspberrypi:~/wmbusmeters $ sudo nano /etc/wmbusmeters.d/meinWasserzaehler
                  pi@raspberrypi:~/wmbusmeters $ cd /etc/wmbusmeters.d
                  -bash: cd: /etc/wmbusmeters.d: Datei oder Verzeichnis nicht gefunden
                  pi@raspberrypi:~/wmbusmeters $ cd
                  pi@raspberrypi:~ $ cd etc
                  -bash: cd: etc: Datei oder Verzeichnis nicht gefunden
                  pi@raspberrypi:~ $ cd 7etc
                  -bash: cd: 7etc: Datei oder Verzeichnis nicht gefunden
                  pi@raspberrypi:~ $ cd /etc
                  pi@raspberrypi:/etc $ makedir wmbusmeters.d
                  -bash: makedir: Kommando nicht gefunden.
                  pi@raspberrypi:/etc $ mkdir wmbusmeters.d
                  mkdir: das Verzeichnis „wmbusmeters.d“ kann nicht angelegt werden: Keine Berecht                                                                                                             igung
                  pi@raspberrypi:/etc $ sudo mkdir wmbusmeters.d
                  pi@raspberrypi:/etc $ sudo nano /etc/wmbusmeters.d/meinWasserzaehler
                  pi@raspberrypi:/etc $ sudo systemctl start wmbusmeters
                  Warning: The unit file, source configuration file or drop-ins of wmbusmeters.ser                                                                                                             vice changed on disk. Run 'systemctl daemon-reload' to reload units.
                  Job for wmbusmeters.service failed because the control process exited with error                                                                                                              code.
                  See "systemctl status wmbusmeters.service" and "journalctl -xe" for details.
                  pi@raspberrypi:/etc $ systemctl status wmbusmeters.service
                  Warning: The unit file, source configuration file or drop-ins of wmbusmeters.service changed on disk. Run 'systemctl daemon-reload' to reload units.
                  ● wmbusmeters.service - "wmbusmeters service"
                     Loaded: loaded (/lib/systemd/system/wmbusmeters.service; enabled; vendor preset: enabled)
                     Active: failed (Result: exit-code) since Tue 2021-06-22 22:27:35 CEST; 30s ago
                       Docs: https://github.com/weetmuts/wmbusmeters
                             man:wmbusmeters(1)
                    Process: 27860 ExecStartPre=/bin/mkdir -p /var/log/wmbusmeters/meter_readings (code=exited, status=217/USER)
                    Process: 27861 ExecStartPre=/bin/chown -R wmbusmeters:wmbusmeters /var/log/wmbusmeters (code=exited, status=217/USER)
                  
                  Jun 22 22:27:34 raspberrypi systemd[1]: wmbusmeters.service: Failed with result 'exit-code'.
                  Jun 22 22:27:34 raspberrypi systemd[1]: Failed to start "wmbusmeters service".
                  Jun 22 22:27:35 raspberrypi systemd[1]: wmbusmeters.service: Service RestartSec=1s expired, scheduling restart.
                  Jun 22 22:27:35 raspberrypi systemd[1]: wmbusmeters.service: Scheduled restart job, restart counter is at 3.
                  Jun 22 22:27:35 raspberrypi systemd[1]: Stopped "wmbusmeters service".
                  Jun 22 22:27:35 raspberrypi systemd[1]: wmbusmeters.service: Start request repeated too quickly.
                  Jun 22 22:27:35 raspberrypi systemd[1]: wmbusmeters.service: Failed with result 'exit-code'.
                  Jun 22 22:27:35 raspberrypi systemd[1]: Failed to start "wmbusmeters service".
                  pi@raspberrypi:/etc $ sudo systemctl daemon-reload
                  pi@raspberrypi:/etc $ systemctl status wmbusmeters.service
                  ● wmbusmeters.service
                     Loaded: not-found (Reason: Unit wmbusmeters.service not found.)
                     Active: failed (Result: exit-code) since Tue 2021-06-22 22:27:35 CEST; 1min 13s ago
                  
                  Jun 22 22:27:34 raspberrypi systemd[1]: wmbusmeters.service: Failed with result 'exit-code'.
                  Jun 22 22:27:34 raspberrypi systemd[1]: Failed to start "wmbusmeters service".
                  Jun 22 22:27:35 raspberrypi systemd[1]: wmbusmeters.service: Service RestartSec=1s expired, scheduling restart.
                  Jun 22 22:27:35 raspberrypi systemd[1]: wmbusmeters.service: Scheduled restart job, restart counter is at 3.
                  Jun 22 22:27:35 raspberrypi systemd[1]: Stopped "wmbusmeters service".
                  Jun 22 22:27:35 raspberrypi systemd[1]: wmbusmeters.service: Start request repeated too quickly.
                  Jun 22 22:27:35 raspberrypi systemd[1]: wmbusmeters.service: Failed with result 'exit-code'.
                  Jun 22 22:27:35 raspberrypi systemd[1]: Failed to start "wmbusmeters service".
                  pi@raspberrypi:/etc $ sudo systemctl start wmbusmeters
                  Failed to start wmbusmeters.service: Unit wmbusmeters.service not found.
                  pi@raspberrypi:/etc $
                  
                  

                  Irgendwie fehlt der service.

                  M 1 Reply Last reply Reply Quote 0
                  • M
                    Michi_Pi @hg6806 last edited by

                    @hg6806 ja, du warst zu schnell, du hast vergessen es zu installieren.
                    Nach make && make test fehlt der Befehl sudo make install

                    Da aber wohl noch was im Verzeichnis liegt, würde ich die Daten nochmal holen.

                    Also so:

                    sudo systemctl stop wmbusmeters
                    cd wmbusmeters
                    git pull https://github.com/weetmuts/wmbusmeters.git
                    sudo make clean
                    sudo make install
                    sudo systemctl daemon-reload
                    

                    danach legst deine configs an und startest den Dienst, wo wie du es eh vorgehabt hattest.

                    hg6806 1 Reply Last reply Reply Quote 0
                    • hg6806
                      hg6806 Most Active @Michi_Pi last edited by hg6806

                      @michi_pi
                      Danke, habe ich so gemacht, wirft jedoch noch immer den Fehler aus:

                      pi@raspberrypi:/etc $ sudo systemctl stop wmbusmeters
                      pi@raspberrypi:/etc $ cd wmbusmeters
                      -bash: cd: wmbusmeters: Datei oder Verzeichnis nicht gefunden
                      pi@raspberrypi:/etc $ cd
                      pi@raspberrypi:~ $ cd wmbusmeters
                      pi@raspberrypi:~/wmbusmeters $ git pull https://github.com/weetmuts/wmbusmeters.git
                      Von https://github.com/weetmuts/wmbusmeters
                       * branch            HEAD       -> FETCH_HEAD
                      Bereits aktuell.
                      pi@raspberrypi:~/wmbusmeters $ sudo make clean
                      Building 1.3.0-23-g08b9153
                      rm -rf build/* build_arm/* build_debug/* build_arm_debug/* *~
                      pi@raspberrypi:~/wmbusmeters $ sudo make install
                      Building 1.3.0-23-g08b9153
                      g++ -Os -fPIC -std=c++11 -Wall -Werror=format-security -Ibuild src/aes.cc -c -E > build/aes.o.src
                      g++ -Os -fPIC -std=c++11 -Wall -Werror=format-security -Ibuild src/aes.cc -MMD -c -o build/aes.o
                      g++ -Os -fPIC -std=c++11 -Wall -Werror=format-sec
                      .......................
                      
                      pi@raspberrypi:~/wmbusmeters $ sudo systemctl daemon-reload
                      pi@raspberrypi:~/wmbusmeters $ sudo nano /etc/wmbusmeters.d/meinWasserzaehler
                      pi@raspberrypi:~/wmbusmeters $ sudo nano /etc/wmbusmeters.conf
                      pi@raspberrypi:~/wmbusmeters $ sudo systemctl start wmbusmeters
                      pi@raspberrypi:~/wmbusmeters $ sudo systemctl enable wmbusmeters
                      pi@raspberrypi:~/wmbusmeters $ systemctl status wmbusmeters.service
                      ● wmbusmeters.service - "wmbusmeters service"
                         Loaded: loaded (/lib/systemd/system/wmbusmeters.service; enabled; vendor preset: enabled)
                         Active: failed (Result: protocol) since Wed 2021-06-23 14:14:04 CEST; 33s ago
                           Docs: https://github.com/weetmuts/wmbusmeters
                                 man:wmbusmeters(1)
                      
                      Jun 23 14:14:04 raspberrypi systemd[1]: wmbusmeters.service: Service RestartSec=1s expired, scheduling restart.
                      Jun 23 14:14:04 raspberrypi systemd[1]: wmbusmeters.service: Scheduled restart job, restart counter is at 3.
                      Jun 23 14:14:04 raspberrypi systemd[1]: Stopped "wmbusmeters service".
                      Jun 23 14:14:04 raspberrypi systemd[1]: wmbusmeters.service: Start request repeated too quickly.
                      Jun 23 14:14:04 raspberrypi systemd[1]: wmbusmeters.service: Failed with result 'protocol'.
                      Jun 23 14:14:04 raspberrypi systemd[1]: Failed to start "wmbusmeters service".
                      pi@raspberrypi:~/wmbusmeters $
                      
                      
                      M 1 Reply Last reply Reply Quote 0
                      • M
                        Michi_Pi @hg6806 last edited by

                        @hg6806 hast schon mal einen neustart durchgeführt?

                        hg6806 1 Reply Last reply Reply Quote 0
                        • hg6806
                          hg6806 Most Active @Michi_Pi last edited by

                          @michi_pi
                          Ja, gerade mal Reboot gemacht.
                          Danach noch immer das Problem:

                          pi@raspberrypi:~ $ sudo systemctl start wmbusmeters
                          Job for wmbusmeters.service failed because the service did not take the steps required by its unit configuration.
                          See "systemctl status wmbusmeters.service" and "journalctl -xe" for details.
                          pi@raspberrypi:~ $ sudo systemctl enable wmbusmeters
                          pi@raspberrypi:~ $
                          pi@raspberrypi:~ $ systemctl status wmbusmeters.service
                          ● wmbusmeters.service - "wmbusmeters service"
                             Loaded: loaded (/lib/systemd/system/wmbusmeters.service; enabled; vendor preset: enabled)
                             Active: failed (Result: exit-code) since Wed 2021-06-23 15:17:55 CEST; 15s ago
                               Docs: https://github.com/weetmuts/wmbusmeters
                                     man:wmbusmeters(1)
                           Main PID: 6031 (code=exited, status=1/FAILURE)
                          
                          Jun 23 15:17:55 raspberrypi systemd[1]: wmbusmeters.service: Service RestartSec=1s expired, scheduling restart.
                          Jun 23 15:17:55 raspberrypi systemd[1]: wmbusmeters.service: Scheduled restart job, restart counter is at 3.
                          Jun 23 15:17:55 raspberrypi systemd[1]: Stopped "wmbusmeters service".
                          Jun 23 15:17:55 raspberrypi systemd[1]: wmbusmeters.service: Start request repeated too quickly.
                          Jun 23 15:17:55 raspberrypi systemd[1]: wmbusmeters.service: Failed with result 'exit-code'.
                          Jun 23 15:17:55 raspberrypi systemd[1]: Failed to start "wmbusmeters service".
                          pi@raspberrypi:~ $ systemctl status wmbusmeters
                          ● wmbusmeters.service - "wmbusmeters service"
                             Loaded: loaded (/lib/systemd/system/wmbusmeters.service; enabled; vendor preset: enabled)
                             Active: failed (Result: exit-code) since Wed 2021-06-23 15:17:55 CEST; 25s ago
                               Docs: https://github.com/weetmuts/wmbusmeters
                                     man:wmbusmeters(1)
                           Main PID: 6031 (code=exited, status=1/FAILURE)
                          
                          Jun 23 15:17:55 raspberrypi systemd[1]: wmbusmeters.service: Service RestartSec=1s expired, scheduling restart.
                          Jun 23 15:17:55 raspberrypi systemd[1]: wmbusmeters.service: Scheduled restart job, restart counter is at 3.
                          Jun 23 15:17:55 raspberrypi systemd[1]: Stopped "wmbusmeters service".
                          Jun 23 15:17:55 raspberrypi systemd[1]: wmbusmeters.service: Start request repeated too quickly.
                          Jun 23 15:17:55 raspberrypi systemd[1]: wmbusmeters.service: Failed with result 'exit-code'.
                          Jun 23 15:17:55 raspberrypi systemd[1]: Failed to start "wmbusmeters service".
                          pi@raspberrypi:~ $
                          
                          

                          An welcher Stelle der Installation sollte man generell ein Reboot machen?

                          M 1 Reply Last reply Reply Quote 0
                          • M
                            Michi_Pi @hg6806 last edited by

                            @hg6806 steht in der Log was drinnen?

                            tail -f /var/log/wmbusmeters/wmbusmeters.log
                            
                            1 Reply Last reply Reply Quote 0
                            • hg6806
                              hg6806 Most Active last edited by

                              @michi_pi sagte in Wasserzähler (Funk 868) auslesen.:

                              tail -f /var/log/wmbusmeters/wmbusmeters.log

                              pi@raspberrypi:~ $ tail -f /var/log/wmbusmeters/wmbusmeters.log
                              tail: '/var/log/wmbusmeters/wmbusmeters.log' kann nicht zum Lesen geöffnet werden: Datei oder Verzeichnis nicht gefunden
                              tail: Keine Dateien mehr übrig
                              
                              
                              1 Reply Last reply Reply Quote 0
                              • hg6806
                                hg6806 Most Active last edited by hg6806

                                Also irgendwie fehlt noch immer der Service:

                                pi@raspberrypi:~/wmbusmeters $ systemctl status wmbusmeters
                                Unit wmbusmeters.service could not be found.
                                pi@raspberrypi:~/wmbusmeters $ sudo make install
                                Building 1.3.0-23-g08b9153
                                binaries: installed /usr/bin/wmbusmeters and /usr/sbin/wmbusmetersd
                                man page: installed /usr/share/man/man1/wmbusmeters.1.gz
                                group: added wmbusmeters
                                user: added wmbusmeters
                                user: added wmbusmeters to dialout group
                                user: added wmbusmeters to uucp group
                                user: added wmbusmeters to plugdev group
                                log: created /var/log/wmbusmeters/meter_readings
                                logrotate: created /etc/logrotate.d/wmbusmeters
                                conf file: created /etc/wmbusmeters.conf
                                conf dir: created /etc/wmbusmeters.d
                                diff: /root/old.wmbusmeters.service.backup: Datei oder Verzeichnis nicht gefunde                                                                                                             n
                                systemd: updated /lib/systemd/system/wmbusmeters.service
                                
                                
                                You need to reload systemd configuration! Please do:
                                sudo systemctl daemon-reload
                                pi@raspberrypi:~/wmbusmeters $ sudo systemctl stop wmbusmeters
                                Failed to stop wmbusmeters.service: Unit wmbusmeters.service not loaded.
                                pi@raspberrypi:~/wmbusmeters $ git pull https://github.com/weetmuts/wmbusmeters.                                                                                                             git
                                Von https://github.com/weetmuts/wmbusmeters
                                 * branch            HEAD       -> FETCH_HEAD
                                Bereits aktuell.
                                pi@raspberrypi:~/wmbusmeters $ sudo make clean
                                Building 1.3.0-23-g08b9153
                                rm -rf build/* build_arm/* build_debug/* build_arm_debug/* *~
                                pi@raspberrypi:~/wmbusmeters $ sudo make install
                                Building 1.3.0-23-g08b9153
                                g++ -Os -fPIC -std=c++11 -Wall -Werror=format-security -Ibuild src/aes.cc -c -E                                                                                                              > build/aes.o.src
                                g++ -Os -fPIC -std=c++11 -Wall -Werror=format-security -Ibuild src/aes.cc -MMD -                                                                                                             c -o build/aes.o
                                g++ -Os -fPIC -std=c++11 -Wall -Werror=format-security -Ibuild src/aescmac.cc -c                                                                                                              -E > build/aescmac.o.src
                                g++ -Os -fPIC -std=c++11 -Wall -Werror=format-security -Ibuild src/aescmac.cc -M                                                                                                             MD -c -o build/aescmac.o
                                g++ -Os -fPIC -std=c++11 -Wall -Werror=format-security -Ibuild src/bus.cc -c -E                                                                                                              > build/bus.o.src
                                g++ -Os -fPIC -std=c++11 -Wall -Werror=format-security -Ibuild src/bus.cc -MMD -                                                                                                             c -o build/bus.o
                                .......
                                g++ -o build/wmbusmeters build/aes.o build/aescmac.o build/bus.o build/cmdline.o build/config.o build/dvparser.o build/mbus_rawtty.o build/meters.o build/manufacturer_specificities.o build/printer.o build/rtlsdr.o build/serial.o build/shell.o build/sha256.o build/threads.o build/util.o build/units.o build/wmbus.o build/meter_auto.o build/meter_unknown.o build/meter_amiplus.o build/wmbus_amb8465.o build/wmbus_im871a.o build/wmbus_cul.o build/wmbus_rtlwmbus.o build/wmbus_rtl433.o build/wmbus_simulator.o build/wmbus_rawtty.o build/wmbus_rc1180.o build/wmbus_utils.o build/meter_apator08.o build/meter_apator162.o build/meter_cma12w.o build/meter_compact5.o build/meter_dme_07.o build/meter_ebzwmbe.o build/meter_ehzp.o build/meter_esyswm.o build/meter_elf.o build/meter_em24.o build/meter_emerlin868.o build/meter_ev200.o build/meter_evo868.o build/meter_eurisii.o build/meter_fhkvdataiii.o build/meter_fhkvdataiv.o build/meter_flowiq2200.o build/meter_hydrus.o build/meter_hydrocalm3.o build/meter_hydrodigit.o build/meter_ei6500.o build/meter_iperl.o build/meter_izar.o build/meter_izar3.o build/meter_lansendw.o build/meter_lansensm.o build/meter_lansenth.o build/meter_lansenpu.o build/meter_lse_07_17.o build/meter_mkradio3.o build/meter_mkradio4.o build/meter_multical21.o build/meter_multical302.o build/meter_multical403.o build/meter_multical603.o build/meter_multical803.o build/meter_omnipower.o build/meter_piigth.o build/meter_q400.o build/meter_qcaloric.o build/meter_rfmamb.o build/meter_rfmtx1.o build/meter_sharky.o build/meter_supercom587.o build/meter_sontex868.o build/meter_topaseskr.o build/meter_tsd2.o build/meter_ultrimis.o build/meter_vario451.o build/meter_waterstarm.o build/meter_whe46x.o build/meter_whe5x.o build/meter_sensostar.o build/meter_gransystems_ccx01.o build/meter_lse_08.o build/meter_weh_07.o  build/main.o  -lrtlsdr -lusb-1.0 -lpthread
                                binaries: installed /usr/bin/wmbusmeters and /usr/sbin/wmbusmetersd
                                man page: installed /usr/share/man/man1/wmbusmeters.1.gz
                                group: wmbusmeters unmodified
                                user: wmbusmeters unmodified
                                user: wmbusmeters already added to dialout
                                user: wmbusmeters already added to uucp
                                user: wmbusmeters already added to plugdev
                                conf file: /etc/logrotate.d/wmbusmeters unchanged
                                conf file: /etc/wmbusmeters.conf unchanged
                                conf dir: /etc/wmbusmeters.d unchanged
                                systemd: backing up /lib/systemd/system/wmbusmeters.service to here: /root/old.wmbusmeters.service.backup
                                systemd: no changes to /lib/systemd/system/wmbusmeters.service
                                pi@raspberrypi:~/wmbusmeters $ sudo systemctl daemon-reload
                                pi@raspberrypi:~/wmbusmeters $ sudo nano /etc/wmbusmeters.conf
                                pi@raspberrypi:~/wmbusmeters $ sudo nano /etc/wmbusmeters.d/meinWasserzaehler
                                pi@raspberrypi:~/wmbusmeters $ sudo systemctl start wmbusmeters
                                pi@raspberrypi:~/wmbusmeters $ sudo systemctl enable wmbusmeters
                                pi@raspberrypi:~/wmbusmeters $ systemctl status wmbusmeters.service
                                ● wmbusmeters.service - "wmbusmeters service"
                                   Loaded: loaded (/lib/systemd/system/wmbusmeters.service; enabled; vendor preset: enabled)
                                   Active: failed (Result: exit-code) since Thu 2021-06-24 17:34:32 CEST; 58s ago
                                     Docs: https://github.com/weetmuts/wmbusmeters
                                           man:wmbusmeters(1)
                                 Main PID: 1110 (code=exited, status=1/FAILURE)
                                
                                Jun 24 17:34:32 raspberrypi systemd[1]: wmbusmeters.service: Service RestartSec=1s expired, scheduling restart.
                                Jun 24 17:34:32 raspberrypi systemd[1]: wmbusmeters.service: Scheduled restart job, restart counter is at 3.
                                Jun 24 17:34:32 raspberrypi systemd[1]: Stopped "wmbusmeters service".
                                Jun 24 17:34:32 raspberrypi systemd[1]: wmbusmeters.service: Start request repeated too quickly.
                                Jun 24 17:34:32 raspberrypi systemd[1]: wmbusmeters.service: Failed with result 'exit-code'.
                                Jun 24 17:34:32 raspberrypi systemd[1]: Failed to start "wmbusmeters service".
                                pi@raspberrypi:~/wmbusmeters $
                                
                                
                                1 Reply Last reply Reply Quote 0
                                • M
                                  Michi_Pi @hg6806 last edited by Michi_Pi

                                  @hg6806 sagte in Wasserzähler (Funk 868) auslesen.:

                                  name=meinwasserzaehler
                                  type=iperl:t1
                                  id=2xxxxxxx6
                                  key=2xxxxxxxxxxxxxxx2

                                  lösche mal das ":t1" hier raus. Denke das ist das Problem.

                                  danach

                                  sudo systemctl daemon-reload
                                  sudo systemctl start wmbusmeters
                                  

                                  Edit: bzw. kannst du die komplette Zeile löschen type=iperl:t1 wird in der neuen Version automatisch erkannt.

                                  1 Reply Last reply Reply Quote 0
                                  • hg6806
                                    hg6806 Most Active last edited by

                                    So, ich wollte nochmal Rückmeldung geben.
                                    Es läuft endlich wieder.

                                    Es lag 1. an dem ":t1". Habe auch das komplette "type:iperl:t1" rausgelöscht.
                                    Status war danach komplett successfull, jedoch kamen trotzdem keine Daten über MQTT.
                                    In der Config hatte komischerweise die beiden Shell-Befehle für MQTT gefehlt, obwohl ich die reinkopiert hatte.

                                    K 1 Reply Last reply Reply Quote 0
                                    • K
                                      knopers1 @hg6806 last edited by knopers1

                                      ich habe auch seit 2021 den Hydrus 171a mit der 868 Funk Schnittstelle.
                                      Wasserverbrauch lässt sich dort aber auch ganz einfach über den Kabel abgreifen.
                                      Hierzu reicht ein ESP8266 mit dem Eingang am 10K Pullup Wiederstand.

                                      Die weiße Leitung liefert bei mir einen Impuls pro 10l Wasser mit einer Wellenlänge von 125ms.
                                      Dies lässt sich locker über einen Counterzähler des ESP´s8266 erfassen und mit dem Betriebsstundenzähler hochrechnen.

                                      1 Reply Last reply Reply Quote 0
                                      • B
                                        Berchemer last edited by

                                        Über die Suchfunktion des Forums konnte ich leider nichts finden.
                                        Meine Suche im Internet war auch nicht von Erfolg gekrönt 😞

                                        Daher die Frage...
                                        Wo kann man denn einen solchen Zähler von Diehl Hydrus 171A/B käuflich erwerben???

                                        Meinetwegen auch über Chat-Funktion, falls eine offene Antwort im Forum als Werbung angesehen würde.

                                        1 Reply Last reply Reply Quote 0
                                        • S
                                          saeft_2003 Most Active last edited by

                                          @csr

                                          Hast du es mittlerweile geschafft deine Kampstrup Wasserzähler per Funk auszulesen?

                                          -cs- sonnenschein 2 Replies Last reply Reply Quote 0
                                          • -cs-
                                            -cs- @saeft_2003 last edited by -cs-

                                            @saeft_2003
                                            Ja, halbherzig, es läuft für mich soweit ausreichend, bin aber für eine Weiterempfehlung noch nicht zufrieden damit.

                                            Aber das wurde hier in dem Thread ja schon besprochen dachte ich. ... muss mir mal Zeit nehmen und nochmal alles lesen.

                                            Mit wmbusmeters und Mosquitto.

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate
                                            FAQ Cloud / IOT
                                            HowTo: Node.js-Update
                                            HowTo: Backup/Restore
                                            Downloads
                                            BLOG

                                            481
                                            Online

                                            31.6k
                                            Users

                                            79.5k
                                            Topics

                                            1.3m
                                            Posts

                                            868 diehl funk oms wasserzähler
                                            23
                                            220
                                            52730
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo