Navigation

    Logo
    • Register
    • Login
    • Search
    • Recent
    • Tags
    • Unread
    • Categories
    • Unreplied
    • Popular
    • GitHub
    • Docu
    • Hilfe
    1. Home
    2. Deutsch
    3. Tester
    4. Test Adapter shuttercontrol v2.0.x

    NEWS

    • Neuer Blog: Fotos und Eindrücke aus Solingen

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    Test Adapter shuttercontrol v2.0.x

    This topic has been deleted. Only users with topic management privileges can see it.
    • simatec
      simatec Developer Most Active @puppet1912 last edited by

      @puppet1912 Welche Version hast du installiert?
      Zeige mal deine Config als JSON

      P 1 Reply Last reply Reply Quote 0
      • simatec
        simatec Developer Most Active @Negalein last edited by simatec

        @negalein sagte in Test Adapter shuttercontrol v1.2.x:

        Ich seh immer wieder im Log shutter conversion is:false. Was hat dies zu bedeuten?

        Das bedeutet nur, dass shuttercontrol erkannt hat, dass deine Rollläden richtigrum agieren.
        Also sprich 100% = geöffnet und 0% = geschlossen

        Sollte die umgekehrt sein, erkennt dies shuttercontrol und konvertiert innerhalb des Adapters und es würde somit für diesen Rollladen shutter conversion is:true erscheinen

        Also eigentlich nur ein debug für die Entwicklung

        1 Reply Last reply Reply Quote 1
        • P
          puppet1912 @Dirk Peter last edited by

          @dirk-peter

          Erstmal danke für den Ansatz. Nutzt du eine CCU oder den AP? Ich nutze den AP und mir fallen in den Logs immer mal wieder Positionen auf, welche mit gefühlt 100 Nachkommastellen angegeben sind. Sowas wie

          Shutter state changed: WzRechts old value = 0.4 new value = 0.0050000000000000044
          

          wobei sicher "new value = 0 " stehen sollte/müsste.

          Hast du die Fahrzeiten dann manuell angepasst oder wie hast du am Ende erreichen können, dass es passte? Ich habe auch schon Kalibrierfahrten über den AP gemacht und die Automatische Endlagenerkennung aktiviert sowie deaktiviert. Der Manu_Mode schleicht sich immer wieder ein.

          Danke und Grüße

          Dirk Peter 1 Reply Last reply Reply Quote 0
          • P
            puppet1912 @simatec last edited by

            @simatec

            Ich habe auf dein Anraten hin die 1.2.1 installiert. Damit wurde es auch schon besser, da mit der 1.2.0 tatsächlich wesentlich häufiger der Manu_Mode ausgelöst wurde.

            Hier meine Konfiguration

            _id	"system.adapter.shuttercontrol.0"
            common	
            name	"shuttercontrol"
            version	"1.2.1"
            title	"shuttercontrol"
            authors	
            0	"simatec <nais@gmx.net>"
            contributors	
            0	"Rene G. <info@rg-engineering.eu>"
            keywords	
            0	"ioBroker"
            1	"Smart Home"
            2	"home automation"
            3	"Rollladen"
            4	"Jalousie"
            5	"Rollladensteuerung"
            license	"MIT"
            platform	"Javascript/Node.js"
            main	"main.js"
            icon	"shuttercontrol.png"
            enabled	true
            extIcon	"https://raw.githubusercontent.com/simatec/ioBroker.shuttercontrol/master/admin/shuttercontrol.png"
            readme	"https://github.com/simatec/ioBroker.shuttercontrol/blob/master/README.md"
            loglevel	"debug"
            mode	"daemon"
            type	"climate-control"
            compact	true
            materialize	true
            connectionType	"local"
            dataSource	"push"
            stopBeforeUpdate	true
            adminUI	
            config	"materialize"
            plugins	
            sentry	
            dsn	"https://5f58df7167d846e3a90bae5414d4fc09@sentry.iobroker.net/62"
            installedFrom	"iobroker.shuttercontrol@1.2.1"
            installedVersion	"1.2.1"
            host	"raspberrypi"
            native	
            livingAutomatic	"livingSunriseSunset"
            W_shutterDownLiving	"21:00"
            W_shutterUpLivingMin	"07:00"
            W_shutterUpLivingMax	"08:30"
            driveDelayUpLiving	"5"
            WE_shutterDownLiving	"22:00"
            WE_shutterUpLivingMin	"08:00"
            WE_shutterUpLivingMax	"09:00"
            sleepAutomatic	"sleepSunriseSunset"
            W_shutterDownSleep	"21:00"
            W_shutterUpSleepMin	"09:00"
            W_shutterUpSleepMax	"10:30"
            driveDelayUpSleep	"5"
            WE_shutterDownSleep	"22:00"
            WE_shutterUpSleepMin	"09:00"
            WE_shutterUpSleepMax	"10:30"
            childrenAutomatic	"childrenSunriseSunset"
            W_shutterDownChildren	"20:00"
            W_shutterUpChildrenMin	"06:00"
            W_shutterUpChildrenMax	"06:30"
            driveDelayUpChildren	"10"
            WE_shutterDownChildren	"21:00"
            WE_shutterUpChildrenMin	"06:00"
            WE_shutterUpChildrenMax	"06:30"
            latitude	"50.95670156243523"
            longitude	"13.930901303870996"
            sunProtEndElevation	"10"
            astroDelayUp	"0"
            astroDelayDown	"20"
            driveDelayUpAstro	"5"
            SummerStart	"01.03."
            SummerEnd	"30.09."
            XMasStart	"01.12."
            XMasEnd	"06.01."
            publicHolidays	true
            publicHolInstance	""
            HolidayDP	""
            lightsensorDown	"400"
            lightsensorUp	"500"
            lightsensorUpDown	""
            schoolfree	false
            schoolfreeInstance	""
            schoolfreeChildrenArea	true
            schoolfreeSleepArea	false
            schoolfreeLivingArea	false
            LateAllDown	false
            LateAllDownTime	"22:15"
            betweenPositionTime	"22:00"
            noGoTime	"0"
            currentShutterState	true
            currentShutterStateTime	"90"
            triggerAutoSleep	""
            triggerAutoLiving	""
            triggerAutoChildren	""
            heightDownSun	"30"
            direction	"120"
            type	"off"
            directionRange	"50"
            actualValueTemp	""
            actualValueLight	""
            actualValueTempInside	""
            typeDown	"sleep"
            typeUp	"sleep"
            triggerStateShutter	"true"
            triggerChangeShutter	"off"
            triggerDriveShutter	"100"
            autoDriveShutter	"off"
            heightDownShutter	"1"
            heightUpShutter	"0"
            triggerID	""
            LateDown	false
            inSummerNotDown	false
            driveAfterClose	false
            useXmasLevel	false
            XmasLevel	"0"
            KeepSunProtect	false
            trigDelyUp	"0"
            trigDelyDown	"0"
            betweenPosition	false
            betweenPositionLevel	"50"
            events	
            0	
            enabled	true
            shutterName	"Kaempfer"
            name	"hmip.0.devices.3014F711A000111A498E3899.channels.1.shutterLevel"
            triggerID	""
            typeUp	"living"
            typeDown	"living"
            type	"only direction"
            heightDownSun	"0.55"
            direction	"120"
            directionRange	"25"
            tempInside	"23"
            tempSensor	""
            outsideTempSensor	""
            tempOutside	"23"
            lightSensor	""
            valueLight	"15"
            heightUp	"0"
            heightDown	"1"
            triggerState	"true"
            triggerDrive	"0"
            triggerChange	"off"
            elevation	""
            autoDrive	"off"
            hysteresisOutside	"5"
            hysteresisInside	"5"
            hysteresisLight	"5"
            currentAction	""
            currentHeight	""
            oldHeight	""
            firstCompleteUp	""
            triggerHeight	""
            LateDown	false
            inSummerNotDown	false
            KeepSunProtect	false
            triggerAction	""
            driveAfterClose	false
            useXmasLevel	false
            XmasLevel	"0"
            betweenPosition	false
            betweenPositionLevel	"50"
            trigDelyUp	"0"
            trigDelyDown	"0"
            1	
            enabled	true
            shutterName	"Kueche"
            name	"hmip.0.devices.3014F711A000111A498E385E.channels.1.shutterLevel"
            triggerID	""
            typeUp	"living"
            typeDown	"living"
            type	"only direction"
            heightDownSun	"0.4"
            direction	"200"
            directionRange	"55"
            tempInside	"23"
            tempSensor	""
            outsideTempSensor	""
            tempOutside	"23"
            lightSensor	""
            valueLight	"15"
            heightUp	"0"
            heightDown	"1"
            triggerState	"true"
            triggerDrive	"1"
            triggerChange	"off"
            elevation	""
            autoDrive	"off"
            hysteresisOutside	"5"
            hysteresisInside	"5"
            hysteresisLight	"5"
            currentAction	""
            currentHeight	""
            oldHeight	""
            firstCompleteUp	""
            triggerHeight	""
            LateDown	false
            inSummerNotDown	false
            KeepSunProtect	false
            triggerAction	""
            driveAfterClose	false
            useXmasLevel	false
            XmasLevel	"0"
            betweenPosition	false
            betweenPositionLevel	"50"
            trigDelyUp	"0"
            trigDelyDown	"0"
            2	
            enabled	true
            shutterName	"Essen"
            name	"hmip.0.devices.3014F711A000111A498E382C.channels.1.shutterLevel"
            triggerID	"hmip.0.devices.3014F711A00007DD898A450E.channels.1.windowOpen"
            typeUp	"living"
            typeDown	"living"
            type	"only direction"
            heightDownSun	"0.4"
            direction	"200"
            directionRange	"55"
            tempInside	"23"
            tempSensor	""
            outsideTempSensor	""
            tempOutside	"23"
            lightSensor	""
            valueLight	"15"
            heightUp	"0"
            heightDown	"1"
            triggerState	"false"
            triggerDrive	"0"
            triggerChange	"upDown"
            elevation	""
            autoDrive	"off"
            hysteresisOutside	"5"
            hysteresisInside	"5"
            hysteresisLight	"5"
            currentAction	""
            currentHeight	""
            oldHeight	""
            firstCompleteUp	""
            triggerHeight	""
            LateDown	false
            inSummerNotDown	false
            KeepSunProtect	false
            triggerAction	""
            driveAfterClose	true
            useXmasLevel	false
            XmasLevel	"0"
            betweenPosition	false
            betweenPositionLevel	"50"
            trigDelyUp	"0"
            trigDelyDown	"0"
            3	
            enabled	true
            shutterName	"WzRechts"
            name	"hmip.0.devices.3014F711A000111A498E3805.channels.1.shutterLevel"
            triggerID	"hmip.0.devices.3014F711A00007DD898A4554.channels.1.windowOpen"
            typeUp	"living"
            typeDown	"living"
            type	"only direction"
            heightDownSun	"0.4"
            direction	"255"
            directionRange	"25"
            tempInside	"23"
            tempSensor	""
            outsideTempSensor	""
            tempOutside	"23"
            lightSensor	""
            valueLight	"15"
            heightUp	"0"
            heightDown	"1"
            triggerState	"false"
            triggerDrive	"0"
            triggerChange	"upDown"
            elevation	""
            autoDrive	"off"
            hysteresisOutside	"5"
            hysteresisInside	"5"
            hysteresisLight	"5"
            currentAction	""
            currentHeight	""
            oldHeight	""
            firstCompleteUp	""
            triggerHeight	""
            LateDown	true
            inSummerNotDown	false
            KeepSunProtect	false
            triggerAction	""
            driveAfterClose	true
            useXmasLevel	false
            XmasLevel	"0"
            betweenPosition	false
            betweenPositionLevel	"50"
            trigDelyUp	"0"
            trigDelyDown	"0"
            4	
            enabled	true
            shutterName	"Treppenhaus"
            name	"hmip.0.devices.3014F711A000111A498E3897.channels.1.shutterLevel"
            triggerID	""
            typeUp	"sleep"
            typeDown	"sleep"
            type	"off"
            heightDownSun	"30"
            direction	"120"
            directionRange	"50"
            tempInside	"23"
            tempSensor	""
            outsideTempSensor	""
            tempOutside	"23"
            lightSensor	""
            valueLight	"15"
            heightUp	"0"
            heightDown	"1"
            triggerState	"true"
            triggerDrive	"100"
            triggerChange	"off"
            elevation	""
            autoDrive	"off"
            hysteresisOutside	"5"
            hysteresisInside	"5"
            hysteresisLight	"5"
            currentAction	""
            currentHeight	""
            oldHeight	""
            firstCompleteUp	""
            triggerHeight	""
            LateDown	false
            inSummerNotDown	false
            KeepSunProtect	false
            triggerAction	""
            driveAfterClose	false
            useXmasLevel	false
            XmasLevel	"0"
            betweenPosition	false
            betweenPositionLevel	"50"
            trigDelyUp	"0"
            trigDelyDown	"0"
            

            Danke und Grüße

            1 Reply Last reply Reply Quote 0
            • Dirk Peter
              Dirk Peter @puppet1912 last edited by

              @puppet1912 Hallo, bei mir wird der DRAP über piVCCU angesteuert. Die Fahrzeiten werden unter den Kanalparametern in den Einstellungen des HmIPW-DRBL4 eingegeben.
              Fahrzeiten.jpg
              In den Werkseinstellungen liegen Sie bei 90 s, real bei mir bei 22 s - 25 s. Seit dem ich die realen Zeiten ermittelt und eingetragen habe, laufen die Rollos so wie sie sollen.
              MfG Dirk Peter

              P 1 Reply Last reply Reply Quote 0
              • P
                puppet1912 @Dirk Peter last edited by

                @dirk-peter said in Test Adapter shuttercontrol v1.2.x:

                HmIPW-DRBL4

                Rein von den Werten her sehe ich zwei Unterschiede. Die Fahrzeiten sind bei dir in "ganzen" Sekunden angeben/eingetragen. Bei mir mit einer Nachkommastelle.
                Des Weiteren hast du keine Zeitverzögerung bei Motorstart eingetragen. Bei mir widerum beträgt diese 1sec. Ich werde mal testen ob dort vll das Problem liegt und ob ich das überhaupt über den AP ändern kann.

                Ich danke dir für den Ansatz!

                Dirk Peter 1 Reply Last reply Reply Quote 0
                • Dirk Peter
                  Dirk Peter @puppet1912 last edited by

                  @puppet1912 Hallo, bei mir kann man im DRBL4 keine Kommastellen eingeben. Wenn die Zeit genauer sein soll, so muss ich auf 1/10 Sekunden bzw. 1/100 Sekunden umschalten. Um dann wieder ganze Zahlen einzugeben.
                  MfG Dirk Peter

                  P 1 Reply Last reply Reply Quote 0
                  • G
                    Gucky28 @simatec last edited by

                    @simatec
                    Hallo Guten Tag,

                    ich habe heute den Adapter Shuttercontrol gefunden. Das scheint genau das zu sein, was ich brauche, aber irgendwie bekomme Ich diesen nicht ans Laufen leider.
                    Nach einigen Recherchen habe ich leider nichts Passendes gefunden was mir weiter hilft.
                    Deshalb schreibe Ich jetzt hier, auch wenn Ich nicht weiß ob Ich hier richtig bin 🙂 (aber ich denke, dass du der Entwickler diese Adapter bist 🙂 ).

                    Also zuerst einmal möchte ich mitteilen was Ich verwende:

                    Iobrocker

                    Homepilot20 genauer Rademacher Bridge mit Duofern 1200

                    Dazu würde Ich gerne Shuttercontrol benutzen, der Adapter hat genau, dass was Ich mir vorstelle.

                    ist denn mein Homepilot20 bzw. Duofern 1200 mit Bridge überhaupt kompatibel?

                    Ich füge mal ein Bild mit den Daten aus Homepilot20 hinzu.

                    Homepilot20.PNG

                    Danke für deine Hilfe

                    PS: wenn der Thread hier falsch ist bitte verschieben Danke

                    Homoran simatec 2 Replies Last reply Reply Quote 0
                    • Homoran
                      Homoran Global Moderator Administrators @Gucky28 last edited by

                      @gucky28 sagte in Test Adapter shuttercontrol v1.2.x:

                      aber irgendwie bekomme Ich diesen nicht ans Laufen leider.

                      wie äußert sich das?

                      Fehlermeldungen?

                      G 1 Reply Last reply Reply Quote 0
                      • G
                        Gucky28 @Homoran last edited by

                        @homoran gar nicht es passiert einfach nichts Fehler Meldung gibt es nicht. Ich denke, vielleicht habe Ich die falschen Daten punkte vom Homepilot20 genommen. Allerdings habe Ich alles ausprobiert, was mir sinnvoll erschienen ist 🙂

                        Homoran 1 Reply Last reply Reply Quote 0
                        • Homoran
                          Homoran Global Moderator Administrators @Gucky28 last edited by

                          @gucky28 dann solltest du vielleicht auch deine shuttercontrol konfig posten

                          1 Reply Last reply Reply Quote 0
                          • simatec
                            simatec Developer Most Active @Gucky28 last edited by

                            @gucky28
                            Fahren die Rollläden mit Änderung des Levels? Also 0-100%

                            G 1 Reply Last reply Reply Quote 0
                            • G
                              Gucky28 @simatec last edited by

                              @simatec ja wenn ich unter Position im Homepilot den Wert ändere fahren die Rolladen rauf oder runter wie ich möchte.

                              simatec 1 Reply Last reply Reply Quote 0
                              • simatec
                                simatec Developer Most Active @Gucky28 last edited by

                                @gucky28
                                Dann musst du das Level für shuttercontrol nehmen.

                                Die einzelnen Funktionen sind hier beschrieben

                                G 1 Reply Last reply Reply Quote 0
                                • P
                                  puppet1912 @Dirk Peter last edited by

                                  @dirk-peter
                                  Hallo und Guten Abend.

                                  Okay, dann unterscheiden sich CCU und AP da wohl etwas. Gut zu wissen.

                                  Mal eine andere Frage: Ich habe ab und an mal das Problem/Phänomen, dass der HomaticIP-Adapter bzw der AP zwischendurch LEVEL-Werte melden, die aber weder manuell noch automatisch gefahren wurden. Das Rollo hat sich definitiv nicht bewegt.

                                  Heute Beispielsweise meldet der Adapter ca. eine Stunde nachdem das Rolle auf 55 % gefahren wurde, kurzzeitig Level= 0%. Eine Sekunde später wiederum meldet er das richtige und aktuelle LEVEL nämlich die eigentlichen 55 %.

                                  Hattest du bereits ähnliche Auffälligkeiten?

                                  Grüße

                                  simatec Negalein Dirk Peter 3 Replies Last reply Reply Quote 0
                                  • G
                                    Gucky28 @simatec last edited by

                                    @simatec okay ich hatte die Werte genau anders rum im Adapter stehen, rauf runter geht jetzt.
                                    Allerdings funktioniert es nicht, dass die Rollade beim Öffnen des Fensters hochfährt. Allerdings passiert folgendes: wenn das Rollo geschlossen ist und ich öffne das Fenster passiert nichts, wenn ich es schließe geht die Rollade hoch. Eigentlich wollte ich das anders rum haben.
                                    Den Aussperrschutz hab ich auch nicht hinbekommen. Zurzeit keine Reaktion.

                                    Danke für deine Hilfe bis hier hin.

                                    Grüße Andreas

                                    simatec 1 Reply Last reply Reply Quote 0
                                    • simatec
                                      simatec Developer Most Active @puppet1912 last edited by

                                      @puppet1912
                                      Es wurde hier gerade vor kurzen erklärt, shuttercontrol macht nix eigenständig, sondern reagiert nur auf Änderungen der States.

                                      P 1 Reply Last reply Reply Quote 0
                                      • simatec
                                        simatec Developer Most Active @Gucky28 last edited by

                                        @gucky28
                                        Dann passt der Wert deines Fensterkontaktes im geschlossenen Zustand in der Config von shuttercontrol nicht.

                                        G 2 Replies Last reply Reply Quote 0
                                        • Negalein
                                          Negalein Global Moderator @puppet1912 last edited by

                                          @puppet1912 sagte in Test Adapter shuttercontrol v1.2.x:

                                          Mal eine andere Frage: Ich habe ab und an mal das Problem/Phänomen, dass der HomaticIP-Adapter bzw der AP zwischendurch LEVEL-Werte melden, die aber weder manuell noch automatisch gefahren wurden. Das Rollo hat sich definitiv nicht bewegt.

                                          Dieses Problem ist eigentlich Geschichte.
                                          Kann nicht sagen ab welcher Version.
                                          Aber @simatec hat das mal gefixt.

                                          Welche Version läuft bei dir?

                                          1 Reply Last reply Reply Quote 0
                                          • Dirk Peter
                                            Dirk Peter @puppet1912 last edited by

                                            @puppet1912 Hallo,

                                            Mal eine andere Frage: Ich habe ab und an mal das Problem/Phänomen, dass der HomaticIP-Adapter bzw der AP zwischendurch LEVEL-Werte melden, die aber weder manuell noch automatisch gefahren wurden. Das Rollo hat sich definitiv nicht bewegt.

                                            Nein, das kann ich nicht bestätigen! Sie fahren bei mir nur dann, wenn sie sollen. Die Level-Werte ändern sich auch nicht zwischendurch.
                                            MfG Dirk Peter

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            689
                                            Online

                                            31.9k
                                            Users

                                            80.2k
                                            Topics

                                            1.3m
                                            Posts

                                            rollladen rollladensteuerung shuttercontrol
                                            330
                                            7347
                                            9769506
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo