      Ich hab dies neuerdings im Log stehen. Was hat das zu bedeuten?

      
      ebus.0
      2021-10-03 09:52:08.245	info	Terminated (NO_ERROR): Without reason
      
      ebus.0
      2021-10-03 09:52:08.243	info	all http done
      
      ebus.0
      2021-10-03 09:52:08.162	info	found ebusd version 21.2
      
      ebus.0
      2021-10-03 09:52:06.724	warn	updateObject: not updated bai.messages.SetMode.fields.hwcflowtempdesired.value value: null
      
      ebus.0
      2021-10-03 09:52:06.721	warn	Key : bai.messages.SetMode.fields.hwcflowtempdesired.value, Value : null name SetMode
      
      ebus.0
      2021-10-03 09:52:06.712	warn	updateObject: not updated bai.messages.SetMode.fields.hwctempdesired.value value: null
      
      ebus.0
      2021-10-03 09:52:06.708	warn	Key : bai.messages.SetMode.fields.hwctempdesired.value, Value : null name SetMode
      
      ebus.0
      2021-10-03 09:52:02.740	info	starting. Version 2.3.2 in /opt/iobroker/node_modules/iobroker.ebus, node: v12.22.6, js-controller: 3.3.18
      
      Rene_HM 1 Reply Last reply Reply Quote 0
      • Rene_HM
        Rene_HM Developer @Cino last edited by

        @cino ebusd stellt den Datenpunkt zwar zur Verfügung, liefert aber keinen Wert dazu. Ich habe das erst mal als Warnung eingebaut, ist aber nur kritisch, wenn man genau den Datenpunkt benötigt...

        1 Reply Last reply Reply Quote 0
        • Timmerx
          Timmerx last edited by

          Hi

          bei mir war das Problem, das der Bus nicht gelaufen ist.

          🙄 🙄 🙄 🙄

          1 Reply Last reply Reply Quote 0
          • D
            Dre83 last edited by

            Hallo in die Runde,
            habe ein kleines Problem. Ich habe ein Gesheizung mit Pufferspeicher, Solarkollektoren und Trinkwasseranlage.

            Daten werden auch alle top geladen.

            address 01: master #6
            address 03: master #11
            address 06: slave #6, scanned "MF=Vaillant;ID=PMS02;SW=0209;HW=8402", loaded "vaillant/06.pms.csv"
            address 08: slave #11, scanned "MF=Vaillant;ID=BAI00;SW=0104;HW=7803", loaded "vaillant/bai.308523.inc", "vaillant/08.bai.csv"
            address 0a: slave, scanned "MF=Vaillant;ID=PMW01;SW=0206;HW=8302", loaded "vaillant/0a.pmw.hwc.csv"
            address 10: master #2
            address 12: slave, scanned "MF=Vaillant;ID=PMW01;SW=0206;HW=8302"
            address 15: slave #2, scanned "MF=Vaillant;ID=70000;SW=0613;HW=6903", loaded "vaillant/15.700.csv"
            address 26: slave, scanned "MF=Vaillant;ID=VR_71;SW=0104;HW=0503", loaded "vaillant/26.vr_71.csv"
            address 31: master #8, ebusd
            address 36: slave #8, ebusd
            address ec: slave, scanned "MF=Vaillant;ID=SOL00;SW=0613;HW=6903", loaded "vaillant/ec.sol.sc.csv"
            address ed: slave, scanned "MF=Vaillant;ID=PMS02;SW=0209;HW=8402"
            address f7: master #20
            address fc: slave #20, scanned "MF=Vaillant;ID=PMW01;SW=0206;HW=8302"
            
            

            Jetzt zum Problem. Sowohl in der "vaillant/06.pms.csv"

            r,,Ntc1Sensor,Ntc1Sensor,,,,"0500",,,tempsensor,,,Temperature in solar flow (from solar collector)
            r,,Ntc2Sensor,Ntc2Sensor,,,,"0600",,,tempsensor,,,Temperature in solar back flow (to solar collector)
            r,,Ntc3Sensor,Ntc3Sensor,,,,"0700",,,tempsensor,,,Temperature in buffer flow (to buffer)
            r,,Ntc4Sensor,Ntc4Sensor,,,,"0800",,,tempsensor,,,Temperature in buffer back flow (from buffer)
            

            als auch in der "0a.pmw.hwc.csv"

            r,,Ntc1Sensor,Ntc1Sensor,,,,"0000",,,tempsensor,,,T1 Temperature
            r,,Ntc2Sensor,Ntc2Sensor,,,,"0100",,,tempsensor,,,T2 Temperature
            r,,Ntc3Sensor,Ntc3Sensor,,,,"0200",,,tempsensor,,,T3 Temperature
            

            stehen NTC1Sensor, NTC2Sensor und NTC3Senor drin.

            Wie kann ich denn bei der Abfrage im ebusd Adapter im ioBroker unterscheiden, welchen er einsammelt.

            ntc.PNG

            Aktuell sammelt er Sensor 1-3 nur vom "hwc" ein und nicht vom "pms".

            Rene_HM 1 Reply Last reply Reply Quote 0
            • Rene_HM
              Rene_HM Developer @Dre83 last edited by

              @dre83 wie sieht denn das ganze in den Datenpunkten in ioBroker aus? Intern schicke ich ein

              read -f  Ntc1Sensor
              

              an den ebusd.
              Du kannst aber auch basierend auf der Doku unter ebusd - Read ein eigenes Kommando bauen, welches du dann auf den Datenpunkt

              ebus.0.cmd
              

              schreibst.

              D 1 Reply Last reply Reply Quote 0
              • D
                Dre83 @Rene_HM last edited by Dre83

                @rene_hm Sorry aber ich verstehe die Frage nicht. Was meinst du mit "wie sieht es in den Datenpunkten aus"?

                Ich habe sowohl unter "pms" als auch bei "sc" und "hwc" z.B. den NTC Sensor 1. Allerdings bekomme ich nur für einen NTC1Sensor, einen NTC2Sensor, einen NTC3Sensor und einen NTC4 Sensor die Daten geliefert. Die anderen Sensoren, welche genauso heißen aktualisiert es nicht

                Also Umgehungslösung habe ich es aktuell so gelöst, dass ich auf dem Raspberry mit einem Cron-Trigger

                sudo crontab -e
                

                die Daten jetzt aller 5 Minuten mit dem Raspberry abfrage. Danach werden auch die Daten aller NTC-Sensoren sauber importiert.

                */5 * * * * ebusctl r -c sc NTC1Sensor
                */5 * * * * ebusctl r -c sc NTC2Sensor
                */5 * * * * ebusctl r -c sc NTC3Sensor
                */5 * * * * ebusctl r -c sc NTC4Sensor
                */5 * * * * ebusctl r -c pms NTC1Sensor
                */5 * * * * ebusctl r -c pms NTC2Sensor
                */5 * * * * ebusctl r -c pms NTC3Sensor
                */5 * * * * ebusctl r -c pms NTC4Sensor
                */5 * * * * ebusctl r -c hwc NTC1Sensor
                */5 * * * * ebusctl r -c hwc NTC2Sensor
                */5 * * * * ebusctl r -c hwc NTC3Sensor
                
                

                Kann ich auch mehrere Kommandos auf ebus.0.cmd legen?
                Wenn ja wie ist dann die Syntax?

                Rene_HM 1 Reply Last reply Reply Quote 0
                • Rene_HM
                  Rene_HM Developer @Dre83 last edited by

                  @dre83 sagte in Adapter: ebus:

                  Kann ich auch mehrere Kommandos auf ebus.0.cmd legen?

                  Du kannst immer nur ein Kommando abschicken. Du kannst das aber per script lösen: erstelle dir ein Kommando nach dem anderen und schicke sie zeitlich versetzt. Alternativ schickst du ein Kommando, wartest auf das Ergebnis in ebus.0.cmdResult und schickst dann das nächste Kommando.

                  D 1 Reply Last reply Reply Quote 0
                  • D
                    Dre83 @Rene_HM last edited by

                    @rene_hm
                    Hi René,
                    habe es genau so mit dem Script umgesetzt wie von Dir beschrieben. Funktioniert wunderbar. Vielen Dank. Somit habe ich jetzt alles zentral im iobroker.
                    Da konnte ich auch meine Cron-Jobs auf dem Raspberry auch löschen. (war ja im Endeffekt das selbe Vorgehen)

                    W 1 Reply Last reply Reply Quote 0
                    • W
                      winny1900 @Dre83 last edited by

                      Hallo zusammen,

                      Bei mir läuft es nun auch so la la.

                      Meine frage: Wenn ich das hier ausführe steht da no data stored

                      root@ServerEbus:/home/pi# ebusctl find
                      boiler nominal = no data stored
                      boiler status = no data stored
                      boiler tb = no data stored
                      broadcast datetime = 11.398;10:15:34;12.10.2021
                      buffer boiler_b = no data stored
                      buffer flow = no data stored
                      buffer heating = no data stored
                      buffer nominal = no data stored
                      buffer status_b = no data stored
                      buffer tpm = no data stored
                      buffer tpo = no data stored
                      circuit1config manualT = no data stored
                      circuit1config status = no data stored
                      circuit1mode manualtemp = no data stored
                      circuit1mode modeC1 = no data stored
                      circuit1preferences dayTH = no data stored
                      circuit1preferences heating_limit = no data stored
                      circuit1preferences heatinglimit = no data stored
                      circuit1preferences nightTH = no data stored
                      circuit1preferences outsideTH = no data stored
                      circuit1preferences pointtemp = no data stored
                      circuit1preferences remotecontrol = no data stored
                      circuit1preferences roomfrost = no data stored
                      circuit1preferences supplyTH = no data stored
                      curveC outsideC = no data stored
                      curveC pointC = no data stored
                      curveC supplyC = no data stored
                      curveH outsideH = no data stored
                      curveH pointH = no data stored
                      curveH supplyH = no data stored
                      heatpump coolkwh = no data stored
                      heatpump coolmwh = -;31;00;00;0;0;0
                      heatpump cycles = no data stored
                      heatpump heatkwh = no data stored
                      heatpump heatmwh = no data stored
                      heatpump hours = no data stored
                      heatpump nominal = no data stored
                      heatpump status = no data stored
                      heatpump tqa = 71;0;0d;02;1000;0;10.8
                      heatpump tqe = 80;1;1d;00;1;7721;0.0
                      heatpump twr = 70;0;0d;02;1000;0;6.9
                      heatpump twv = 7;0;0d;02;1000;0;32.0
                      heatpump volumekwh = no data stored
                      heatpump volumemwh = no data stored
                      heatpump waterkwh = no data stored
                      heatpump watermwh = no data stored
                      heatpump_m mode = 53;1;00;00;255;0;Extern gesperrt
                      master 10u0503 = 1;0;0;0.0;1;0
                      master data1 = 32.398;-;0;0;0;0;0;0;1;27.398
                      master data2 = 0.000;53.000;0;0;2
                      scan.06  = TEM;25440;0113;0000
                      scan.08  = TEM;WE_1 ;3632;3030
                      scan.15  = TEM;24849;0605;0102
                      scan.18  = TEM;WE_2 ;3632;3030
                      target dayC = no data stored
                      target dayH = no data stored
                      target limitH = no data stored
                      target nightC = no data stored
                      target nightH = no data stored
                      target SpointS = no data stored
                      target Ssummer = no data stored
                      temperature boiler2 = no data stored
                      temperature buffer1 = 96;0;0d;02;1000;0;32.4
                      temperature buffer2 = no data stored
                      temperature outside1 = no data stored
                      temperature outside2 = no data stored
                      temperature outside = 0;0;0d;02;500;-500;11.4
                      temperature tqe1 = no data stored
                      temperature twr1 = no data stored
                      temperature twv1 = no data stored
                      temperature water = 4;0;0d;02;1000;0;52.3
                      unknow 01940048 = no data stored
                      unknow 01960042 = no data stored
                      unknow 01cc0042 = no data stored
                      unknow 02c60040 = 70;65;04;28;-1;0;192
                      unknow 02c80040 = 72;65;04;2a;1439;0;103
                      
                      

                      Dann kann ich mit z.B.

                      root@ServerEbus:/home/pi# ebusctl r -c heatpump volumekwh
                      218;10;0d;34;1000;0;0.0
                      

                      den wert holen.

                      Nach einen reboot sind diese Werte alle wieder auf no data stored.

                      Gibt's da ne Lösung für?

                      Rene_HM 1 Reply Last reply Reply Quote 0
                      • Rene_HM
                        Rene_HM Developer @winny1900 last edited by

                        @winny1900 typischerweise lauscht der ebusd nur, was am Bus vorbeikommt. Wenn kein anderes Gerät die Daten abfragt, gelangen sie nicht auf den Bus und somit auch nicht in ebusd. Zusätzlich speichert ebusd keine Daten. Wenn du also möchtest, das bestimmte Daten aktualisiert werden, musst du sie aktiv abfragen, was du ja mit

                        ebusctl r
                        

                        schon machst.

                        W 1 Reply Last reply Reply Quote 0
                        • W
                          winny1900 @Rene_HM last edited by

                          @rene_hm also wenn ich dieses einmal eingelesen habe sind die Werte ja einmal da.

                          Wofür kann ich im ebus Adapter die Abfrage Werte eintragen die mit einem , getrennt werden?

                          Oder muss ich wenn ich diese Werte alle 5 min aktualisiert haben möchte das über ein Script lösen

                          Rene_HM 1 Reply Last reply Reply Quote 0
                          • Rene_HM
                            Rene_HM Developer @winny1900 last edited by

                            @winny1900 sagte in Adapter: ebus:

                            Wofür kann ich im ebus Adapter die Abfrage Werte eintragen die mit einem , getrennt werden?
                            Oder muss ich wenn ich diese Werte alle 5 min aktualisiert haben möchte das über ein Script lösen

                            nein, genau dafür ist die Funktion da. Ich schicke für jeden Wert, der in der Liste steht ein "read" an den ebusd inkl. Parameter, dass der read auch auf den Bus gelegt wird.. Das mit dem script benötigt man, wenn man weitere Parameter nutzen möchte, wie z.bsp. von @Dre83 oben beschrieben wurde

                            W 1 Reply Last reply Reply Quote 0
                            • W
                              winny1900 @Rene_HM last edited by

                              @rene_hm okay das heißt wenn ich möchte das heatpump tqa ausgelesen wird, muss ich das dann da eintragen. Der Abfrage Punkt wäre tqa,usw......

                              Rene_HM 1 Reply Last reply Reply Quote 0
                              • Rene_HM
                                Rene_HM Developer @winny1900 last edited by

                                @winny1900 du musst den Namen des Datenpunktes (z.Bsp. tqa) eintragen. Bei mir sieht das so aus:

                                bild.PNG

                                W 1 Reply Last reply Reply Quote 0
                                • W
                                  winny1900 @Rene_HM last edited by

                                  @rene_hm

                                  Wie ist den die richtige Schreibweise ? 2.JPG 1.JPG

                                  hier heißt es buffer nominal und in der HTML nur nominal. Nominal gibt es auch mehrmal.

                                  Müsste ich dann nominal, eitragen oder buffernominal, ??

                                  Rene_HM 1 Reply Last reply Reply Quote 0
                                  • Rene_HM
                                    Rene_HM Developer @winny1900 last edited by

                                    @winny1900 schau bitte die Datenpunkte in ioBroker an. Dort nimmst du den nur Namen des Datenpunktes.

                                    W 1 Reply Last reply Reply Quote 0
                                    • W
                                      winny1900 @Rene_HM last edited by

                                      @rene_hm muss ich dafür Telnet haben ?

                                      Weil die Werte stehen so in der Config.

                                      Rene_HM 1 Reply Last reply Reply Quote 0
                                      • Rene_HM
                                        Rene_HM Developer @winny1900 last edited by

                                        @winny1900 nein, siehe hier (als Beispiel):
                                        bild.PNG

                                        1 Reply Last reply Reply Quote 0
                                        • W
                                          winny1904 last edited by

                                          2.PNG 1.PNG

                                          hab ich ja so richtig.

                                          Der Wert ist von 17:37 Uhr . Aktuell sind es 22,3

                                          3.PNG

                                          Nach dem ich auf dem PI
                                          ebusctl r -c temperature tqa1

                                          wird wieder Aktualsiert

                                          Rene_HM 1 Reply Last reply Reply Quote 0
                                          • Rene_HM
                                            Rene_HM Developer @winny1904 last edited by Rene_HM

                                            @winny1904 kannst du den Adapter mal auf debug schalten und schauen, welche Meldungen bzgl. tqa1 kommen?

                                            es wird geloggt, was per telnet gesendet wird und was vom ebusd wieder zurück kommt.
                                            Beispiel:

                                            2021-10-14 19:25:07.437	debug	received on for Hc1Pump
                                            2021-10-14 19:25:07.279	debug	send cmd read -f Hc1Pump
                                            2021-10-14 19:25:07.277	debug	received on for CirPump
                                            2021-10-14 19:25:07.083	debug	send cmd read -f CirPump
                                            

                                            Du kannst auch versuchen, anstatt

                                            tqa1
                                            

                                            den gleichen string wie am Raspi in die Liste aufzunehmen (ohne "ebusctl r ")

                                            -c temperature tqa1
                                            

                                            Komma kommt dann hinter tqa1 und dann das gleiche für den nächsten Wert...
                                            @Dre83 das könnte auch bei dir funktionieren...

                                            Rene_HM 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate
                                            FAQ Cloud / IOT
                                            HowTo: Node.js-Update
                                            HowTo: Backup/Restore
                                            Downloads
                                            BLOG

                                            563
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            ebus adapter
                                            68
                                            677
                                            148791
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo