Guten morgen,
auch nach einem Neustart von Iobroker (net stop / net start iobroker) habe ich weder Debug Ausgaben noch dekodierte Werte im Jeelink.
Was aber wieder auf Anhieb geht ist der Empfang aller DTHs von Lacrosse. Habe dazu keine Idee.
! ````
jeelink.0 2017-03-03 05:57:40.485 info data received: H001800640148
jeelink.0 2017-03-03 05:57:40.298 info data received: H003500880142
jeelink.0 2017-03-03 05:57:40.032 info data received: H004400320239
jeelink.0 2017-03-03 05:57:39.157 info data received: H00801270000
jeelink.0 2017-03-03 05:57:38.845 info data received: H003200850143
jeelink.0 2017-03-03 05:57:38.501 info data received: H00801190000
jeelink.0 2017-03-03 05:57:36.345 info data received: H001800650148
jeelink.0 2017-03-03 05:57:36.016 info data received: H003500880142
jeelink.0 2017-03-03 05:57:34.876 info data received: H001900700153
jeelink.0 2017-03-03 05:57:34.454 info data received: H00801190000
jeelink.0 2017-03-03 05:57:33.673 info data received: H004200850145
jeelink.0 2017-03-03 05:57:32.704 info data received: H004800430148
jeelink.0 2017-03-03 05:57:32.188 info data received: H001800640148
jeelink.0 2017-03-03 05:57:31.266 info data received: H004400320239
jeelink.0 2017-03-03 05:57:30.345 info data received: H003200850143
jeelink.0 2017-03-03 05:57:28.345 info data received: H004800430148
jeelink.0 2017-03-03 05:57:27.470 info data received: H003500880141
jeelink.0 2017-03-03 05:57:26.501 info data received: H001900700153
jeelink.0 2017-03-03 05:57:26.313 info data received: H00801190000
jeelink.0 2017-03-03 05:57:25.016 info data received: H004200850145
jeelink.0 2017-03-03 05:57:23.923 info data received: H001800640148
jeelink.0 2017-03-03 05:57:22.923 info data received: H00801270000
jeelink.0 2017-03-03 05:57:22.579 info data received: H004400320239
jeelink.0 2017-03-03 05:57:22.251 info data received: H00801190000
jeelink.0 2017-03-03 05:57:21.845 info data received: H003200850143
jeelink.0 2017-03-03 05:57:19.766 info data received: H001800640148
jeelink.0 2017-03-03 05:57:19.579 info data received: H004800440148
jeelink.0 2017-03-03 05:57:18.188 info data received: H00801190000
jeelink.0 2017-03-03 05:57:16.360 info data received: H004200850145
jeelink.0 2017-03-03 05:57:15.641 info data received: H001800640148
jeelink.0 2017-03-03 05:57:15.220 info data received: H004800430148
jeelink.0 2017-03-03 05:57:14.657 info data received: H003500880141
jeelink.0 2017-03-03 05:57:14.126 info data received: H00801190000
jeelink.0 2017-03-03 05:57:13.376 info data received: H003200850143
jeelink.0 2017-03-03 05:57:11.501 info data received: H001800650148
jeelink.0 2017-03-03 05:57:10.376 info data received: H003500880141
jeelink.0 2017-03-03 05:57:10.063 info data received: H00801190000
jeelink.0 2017-03-03 05:57:09.907 info data received: H001900700153
jeelink.0 2017-03-03 05:57:07.720 info data received: H004200850145
jeelink.0 2017-03-03 05:57:07.360 info data received: H001800640148
jeelink.0 2017-03-03 05:57:06.673 info data received: H00801270000
jeelink.0 2017-03-03 05:57:06.454 info data received: H004800440148
jeelink.0 2017-03-03 05:57:06.001 info data received: H00801190000
jeelink.0 2017-03-03 05:57:05.220 info data received: H004400320239
jeelink.0 2017-03-03 05:57:04.845 info data received: H003200850143
jeelink.0 2017-03-03 05:57:02.110 info data received: H004800430148
jeelink.0 2017-03-03 05:57:01.938 info data received: H00801190000
jeelink.0 2017-03-03 05:57:01.610 info data received: H001900700153
jeelink.0 2017-03-03 05:56:59.079 info data received: H004200850145
jeelink.0 2017-03-03 05:56:58.532 info data received: H00801270000
jeelink.0 2017-03-03 05:56:57.876 info data received: H00801190000
jeelink.0 2017-03-03 05:56:57.704 info data received: H004800440148
jeelink.0 2017-03-03 05:56:57.563 info data received: H003500880141
jeelink.0 2017-03-03 05:56:56.516 info data received: H004400320239
jeelink.0 2017-03-03 05:56:56.329 info data received: H003200850143
jeelink.0 2017-03-03 05:56:54.470 info data received: H00801270000
jeelink.0 2017-03-03 05:56:53.813 info data received: H00801190000
jeelink.0 2017-03-03 05:56:53.298 info data received: H001900700153
jeelink.0 2017-03-03 05:56:50.798 info data received: H001800640148
jeelink.0 2017-03-03 05:56:50.407 info data received: H004200850145
jeelink.0 2017-03-03 05:56:49.751 info data received: H00801190000
jeelink.0 2017-03-03 05:56:48.970 info data received: H004800440148
jeelink.0 2017-03-03 05:56:47.829 info data received: H004400320239
jeelink.0 2017-03-03 05:56:45.689 info data received: H00801190000
jeelink.0 2017-03-03 05:56:44.735 info data received: H003500880141
jeelink.0 2017-03-03 05:56:44.579 info data received: H004800430148
jeelink.0 2017-03-03 05:56:42.516 info data received: H001800640148
jeelink.0 2017-03-03 05:56:41.626 info data received: H00801190000
jeelink.0 2017-03-03 05:56:40.470 info data received: H003500880141
jeelink.0 2017-03-03 05:56:39.344 info data received: H003200850143
jeelink.0 2017-03-03 05:56:39.173 info data received: H004400320239
jeelink.0 2017-03-03 05:56:38.219 info data received: H00801270000
jeelink.0 2017-03-03 05:56:37.564 info data received: H00801190000
jeelink.0 2017-03-03 05:56:36.719 info data received: H001900700153
jeelink.0 2017-03-03 05:56:36.188 info data received: H003500880142
jeelink.0 2017-03-03 05:56:35.845 info data received: H004800440148
jeelink.0 2017-03-03 05:56:34.173 info data received: H00801270000
jeelink.0 2017-03-03 05:56:33.501 info data received: H00801190000
jeelink.0 2017-03-03 05:56:33.079 info data received: H004200850145
jeelink.0 2017-03-03 05:56:31.923 info data received: H003500880141
jeelink.0 2017-03-03 05:56:31.454 info data received: H004800440148
jeelink.0 2017-03-03 05:56:30.829 info data received: H003200850143
jeelink.0 2017-03-03 05:56:30.454 info data received: H004400320239
jeelink.0 2017-03-03 05:56:30.313 info [LaCrosseITPlusReader.10.1g_HMS_mod3 (RFM69CW) @17241 kbps / 868300 kHz]
jeelink.0 2017-03-03 05:56:30.313 info data received:
jeelink.0 2017-03-03 05:56:28.518 info open
jeelink.0 2017-03-03 05:56:28.329 info RFM12B setting up object = LaCrosse 1
jeelink.0 2017-03-03 05:56:28.329 info RFM12B setting up object = LaCrosse 2
jeelink.0 2017-03-03 05:56:28.329 info entered ready
jeelink.0 2017-03-03 05:56:28.313 info starting. Version 0.0.3 in C:/ioBroker/node_modules/iobroker.jeelink, node: v4.5.0
jeelink.0 2017-03-03 05:56:28.266 debug statesDB connected
jeelink.0 2017-03-03 05:56:28.219 debug objectDB connected -
Guten morgen,
auch nach einem Neustart von Iobroker (net stop / net start iobroker) habe ich weder Debug Ausgaben noch dekodierte Werte im Jeelink.
Was aber wieder auf Anhieb geht ist der Empfang aller DTHs von Lacrosse. Habe dazu keine Idee. `
Guten Morgen,
Evtl. Meinte simpixio nicht die net-Befehle, sondern eher die Befehle im iobroker Verzeichnis:
iobroker list instances
iobroker stop jeelink
iobroker start jeelink
Könntest du auch einmal oben links "alles" auswählen und nicht nur den jeelink.0? Da hatte ich öfters mal Unterschiede, manchmal hilft auch zwischen den tabs zu wechseln.
Ohne debug-log siehts schwierig aus.
Gruß
Klaus
Gesendet von iPhone mit Tapatalk
-
Irgendwie geht der Debug Modus beim Jeelink nicht, scheint mir. Bis auf die Meldung mit der States DB kommt nichts mehr.
Habe auch nur eine Instanz laufen.
Der RFlink Adapter (Bild) ist gesprächiger im Debug Modus.
! ````
c:\ioBroker>iobroker list instances
c:\ioBroker>node node_modules/iobroker.js-controller/iobroker.js list instances
system.adapter.admin.0 : admin - enabled, port: 8081, bind: 0.0.0.0 (SSL), run as: admin
system.adapter.cloud.0 : cloud - disabled
system.adapter.dwd.0 : dwd - enabled
system.adapter.history.0 : history - enabled
system.adapter.hm-rega.0 : hm-rega - enabled
system.adapter.hm-rpc.0 : hm-rpc - enabled, port: 0
system.adapter.hm-rpc.1 : hm-rpc - enabled, port: 0
system.adapter.hm-rpc.2 : hm-rpc - enabled, port: 0
system.adapter.ical.0 : ical - enabled
system.adapter.icons-material-svg.0 : icons-material-svg - enabled
system.adapter.icons-mfd-svg.0 : icons-mfd-svg - enabled
system.adapter.javascript.0 : javascript - enabled
system.adapter.jeelink.0 : jeelink - enabled
system.adapter.mobile.0 : mobile - disabled
system.adapter.node-red.0 : node-red - disabled, port: 1880
system.adapter.parser.0 : parser - disabled
system.adapter.ping.0 : ping - enabled
system.adapter.rflink.0 : rflink - enabled
system.adapter.rickshaw.0 : rickshaw - enabled
system.adapter.sayit.0 : sayit - disabled, port: 0
system.adapter.scenes.0 : scenes - enabled
system.adapter.socketio.0 : socketio - enabled, port: 8084, bind: 0.0.0.0 (SSL), run as: admin
system.adapter.tr-064.0 : tr-064 - enabled
system.adapter.upnp.0 : upnp - disabled
system.adapter.vis.0 : vis - enabled
system.adapter.web.0 : web - enabled, port: 8082, bind: 0.0.0.0 (SSL), run as: admin
system.adapter.yr.0 : yr - enabled
! c:\ioBroker>iobroker stop jeelink
! c:\ioBroker>node node_modules/iobroker.js-controller/iobroker.js stop jeelink
Adapter "jeelink.0 stopped.
! c:\ioBroker>iobroker start jeelink
! c:\ioBroker>node node_modules/iobroker.js-controller/iobroker.js start jeelink
Adapter "jeelink.0 started.>! ```` Drücke Strg+A und danach Strg+C, um den Inhalt in die Zwischenablage zu kopieren. Klicke irgendwo, um das Fenster zu schliessen. jeelink.0 2017-03-03 20:19:22.904 info data received: H00801770000 jeelink.0 2017-03-03 20:19:22.310 info data received: H00801740000 jeelink.0 2017-03-03 20:19:21.091 info data received: H004800530148 jeelink.0 2017-03-03 20:19:20.794 info data received: H003500050242 jeelink.0 2017-03-03 20:19:19.654 info data received: H004400000237 jeelink.0 2017-03-03 20:19:18.904 info data received: H00801770000 jeelink.0 2017-03-03 20:19:18.263 info data received: H00801740000 jeelink.0 2017-03-03 20:19:17.888 info data received: H004200850147 jeelink.0 2017-03-03 20:19:16.701 info data received: H004800530148 jeelink.0 2017-03-03 20:19:16.529 info data received: H003500050242 jeelink.0 2017-03-03 20:19:16.325 info data received: H003200180241 jeelink.0 2017-03-03 20:19:14.200 info data received: H00801740000 jeelink.0 2017-03-03 20:19:12.247 info data received: H003500050242 jeelink.0 2017-03-03 20:19:10.966 info data received: H004400990137 jeelink.0 2017-03-03 20:19:10.716 info data received: H00801770000 jeelink.0 2017-03-03 20:19:10.122 info data received: H00801740000 jeelink.0 2017-03-03 20:19:09.450 info data received: [LaCrosseITPlusReader.10.1g_HMS_mod3 (RFM69CW) @17241 kbps / 868300 kHz] jeelink.0 2017-03-03 20:19:07.638 info open jeelink.0 2017-03-03 20:19:07.325 info RFM12B setting up object = LaCrosse 1 jeelink.0 2017-03-03 20:19:07.325 info RFM12B setting up object = LaCrosse 2 jeelink.0 2017-03-03 20:19:07.325 info entered ready jeelink.0 2017-03-03 20:19:07.325 info starting. Version 0.0.3 in C:/ioBroker/node_modules/iobroker.jeelink, node: v4.5.0 host.Smarthub 2017-03-03 20:19:05.795 info instance system.adapter.jeelink.0 started with pid 3380 host.Smarthub 2017-03-03 20:19:05.795 info 'system.adapter.jeelink.0' enabled host.Smarthub 2017-03-03 20:19:05.795 info object change system.adapter.jeelink.0 rflink.0 2017-03-03 20:19:03.888 warn Wrong serial data: ; host.Smarthub 2017-03-03 20:18:49.873 info instance system.adapter.jeelink.0 terminated with code null () host.Smarthub 2017-03-03 20:18:49.873 warn instance system.adapter.jeelink.0 terminated due to SIGTERM host.Smarthub 2017-03-03 20:18:49.732 info stopInstance system.adapter.jeelink.0 killing pid 1608 host.Smarthub 2017-03-03 20:18:49.732 info stopInstance system.adapter.jeelink.0 host.Smarthub 2017-03-03 20:18:49.732 info 'system.adapter.jeelink.0' disabled host.Smarthub 2017-03-03 20:18:49.732 info object change system.adapter.jeelink.0 jeelink.0 2017-03-03 20:18:46.607 info data received: H003500050242 host.Smarthub 2017-03-03 20:18:46.545 error WARNING: cannot find logs with id = 86695495 jeelink.0 2017-03-03 20:18:46.076 info data received: H004800530148 jeelink.0 2017-03-03 20:18:45.779 info data received: H00801740000 jeelink.0 2017-03-03 20:18:45.045 info data received: H004400990137 host.Smarthub 2017-03-03 20:18:44.998 error WARNING: cannot find logs with id = 86693273 jeelink.0 2017-03-03 20:18:43.545 info data received: H001900720151 jeelink.0 2017-03-03 20:18:43.280 info data received: H004200850147 jeelink.0 2017-03-03 20:18:42.279 info data received: H00801770000 jeelink.0 2017-03-03 20:18:41.716 info data received: H00801740000 host.Smarthub 2017-03-03 20:18:41.701 error WARNING: cannot find logs with id = 86693019 jeelink.0 2017-03-03 20:18:38.154 info data received: H003500050242 jeelink.0 2017-03-03 20:18:37.951 info data received: H00801740000 history.0 2017-03-03 20:18:41.201 info init timed Relog: disable relog because state not set so far hm-rpc.0.NEQ0948175.0.AES_KEY: null history.0 2017-03-03 20:18:41.201 info init timed Relog: disable relog because state not set so far hm-rpc.0.NEQ0948175.0.AES_KEY: null history.0 2017-03-03 20:18:41.201 info init timed Relog: disable relog because state not set so far hm-rpc.0.NEQ0948175.0.AES_KEY: null history.0 2017-03-03 20:18:40.888 info init timed Relog: disable relog because state not set so far hm-rpc.0.NEQ0387055.0.AES_KEY: null history.0 2017-03-03 20:18:40.888 info init timed Relog: disable relog because state not set so far hm-rpc.0.NEQ0387055.0.AES_KEY: null history.0 2017-03-03 20:18:40.888 info init timed Relog: disable relog because state not set so far hm-rpc.0.NEQ0387055.0.AES_KEY: null history.0 2017-03-03 20:18:40.888 info init timed Relog: disable relog because state not set so far hm-rpc.0.NEQ0387055.1.INSTALL_TEST: null history.0 2017-03-03 20:18:40.888 info init timed Relog: disable relog because state not set so far hm-rpc.0.NEQ0387055.1.INSTALL_TEST: null history.0 2017-03-03 20:18:40.888 info init timed Relog: disable relog because state not set so far hm-rpc.0.NEQ0387055.1.INSTALL_TEST: null >! ```` [1443_bildschirmfoto_2017-03-03_um_20.29.24.png](/assets/uploads/files/1443_bildschirmfoto_2017-03-03_um_20.29.24.png)
-
Das ist sehr komisch, weil der debug Modus mir sehr beim programmieren geholfen hat. Arbeite grad an nem Update um die unbekannten Sensoren im Admin aufzulisten, aber das löst nicht das debug Problem. Werde evtl. Standardmäßig debug einstellen.
Gesendet von iPhone mit Tapatalk
-
Also, nochmal drübergeschaut. Das Programm wertet nur empfangene Telegramme aus, die mit OK beginnen und DTH Sensoren sollten mit 9 standardmäßig beginnen. Weil es nicht mit OK beginnt, gibt es auch keine debug Meldungen, weil kein weiteres Programm durchlaufen wird.
Was für Sensoren sind es (Typ und Hersteller)?
Welche Firmware wird auf dem Stick verwendet?
Unter Umständen muss ich den Adapter erweitern, um neue Sensoren zu unterstützen.
Gruß
Klaus
-
Hallo,
ich habe jetzt ein paar Stunden zugebracht den original Jeelink v3c zum laufen zu bringen. Vielleicht hilft es ja weiter.
<u>Flashen:</u>
Für mich, Lacrosse Sketch Hex 10.1q herunterladen.
Avrdude installieren
avrdude -p atmega328P -c arduino -P /dev/ttyUSB1 -D -U flash:w:./JeeLink_LaCrosse.hex 2>./JeeLinkFlash.log
Was unbedingt noch automatisiert werden muss ist der Modus, sonst empfängt man nichts.
Im Terminal:````
echo "3m 30t v" > /dev/ttyUSB1Dann wechselt er alle 30 Sekunden zwischen den beiden Datenraten 17.241 kbps (TX29) und 9.579 kbps (TX35). ![721_jeelink.jpg](/assets/uploads/files/721_jeelink.jpg) Gruß Marco
-
` > Was für Sensoren sind es (Typ und Hersteller)?
Welche Firmware wird auf dem Stick verwendet? `
Hallo, es sind ganz "normale" mit TX29DHT-IT von Amazon. Ein JeeLink v3c mit der Firmware aus dem Homatic Forum (LaCrosseITPlusReader.10.1g_HMS_mod3). Die neuere Q Firmware die hier immer mal wieder angesprochen wir habe ich nirgends als einzel Download gefunden. Wie gesagt der Jeelink funktioniert mit CuxD an der CCU2 problemlos. Ich liefer aber gerne mehr Daten wenn gewünscht oder teste neue Versionen vom Adapter.
LG
-
Hallo Marcolotti,
da ich nur Windows habe nützt die Linux Anleitung wenig um das Problem nachzustellen. Aber es wäre schön wenn du den Download Link für den "Q" Sketch des Lacrosse Readers posten könntest.
-
Hallo, es sind ganz "normale" mit TX29DHT-IT von Amazon. Ein JeeLink v3c mit der Firmware aus dem Homatic Forum (LaCrosseITPlusReader.10.1g_HMS_mod3). Die neuere Q Firmware die hier immer mal wieder angesprochen wir habe ich nirgends als einzel Download gefunden. Wie gesagt der Jeelink funktioniert mit CuxD an der CCU2 problemlos. Ich liefer aber gerne mehr Daten wenn gewünscht oder teste neue Versionen vom Adapter.
LG `
Die gleiche Konstellation habe ich auch! Und bei mir rennt alles wunderbar! Es wäre ja gelacht wenn wir den Fehler nicht finden würden
Gruß
Adrian
Gesendet von iPhone mit Tapatalk Pro
-
Die gleiche Konstellation habe ich auch! Und bei mir rennt alles wunderbar! Es wäre ja gelacht wenn wir den Fehler nicht finden würden `
Ich weiss nicht wie es bei dir ist - ich bin aber schon auf Admin ist 1.6.12 und js-controller ist 0.16.1.
-
ich bin aber schon auf Admin ist 1.6.12 und js-controller ist 0.16.1. `
Ja die gleichen Version habe ich auch
Admin - 1.6.12
Js-controller - 0.16.1
JeeLink - 0.3
NodeJS - v4.7.3
mein Jeelink hat die folgende Firmware -> [LaCrosseITPlusReader.10.1h (RFM69CW) @17241 kbps / 868300 kHz]
Meine Adapter Einstellungen so:
Du betreibst deinen jeelink unter windows oder auch unter linux?
Gruß
Adrian
-
Nein nur unter Windows. Habe daher COM4 als Port.
1443_bildschirmfoto_2017-03-04_um_15.33.18.png -
Kannst du nochmal die Jeelink auf debug stellen unter Instanz und dann den Log noch mal posten?
Bei mir sieht das nämlich so aus
-
Auch wenn mich hier alle für verrückt halten bei mir kommt da nix im Debug Modus.
1443_bildschirmfoto_2017-03-04_um_15.44.39.png
1443_bildschirmfoto_2017-03-04_um_15.44.14.png -
Hmmm ok…. da muss der Entwickler was dazu sagen! Der Adapter ist in Debug Modus aber schaltet scheinbar nicht in diesen um!
Hast du schon mal versucht den Adapter einmal komplett zu löschen und noch mal zu installieren!?
Gruß
Adrian
Gesendet von iPhone mit Tapatalk Pro
-
Also die Neuinstallation hatte ich noch nicht in Betracht gezogen. Aber jetzt mal gemacht. Leider das selbe Ergebnis. Der Adapter geht in den Debug (siehe Bild) liefert aber nur wenig Meldungen. Der Connect zur States steht ja in der Debug Ausgabe nur eben nicht mehr.
1443_bildschirmfoto_2017-03-04_um_16.17.04.png -
Für mich sieht es so aus als ob der Adapter kurz in den Debug Modus wechselt aber danach wieder in den Info Modus
Kannst du was dazu sagen!? Ist das vielleicht ein Bug [emoji220] unter Windows!?
Gruß
Adrian
Gesendet von iPhone mit Tapatalk Pro
-
Hmmm ok…. da muss der Entwickler was dazu sagen! Der Adapter ist in Debug Modus aber schaltet scheinbar nicht in diesen um! `
Wie schon weiter oben geschrieben, nochmal deutlicher.
Der Adapter befindet sich schon im debug Modus, also das ist ok.
Da aber die empfangenen Daten nicht mit OK beginnen, tritt der Adapter nicht weiter in Aktion. Für den Code sind die Telegramme mit "H00…" keine gültigen, die damit auch nicht ausgewertet werden.
Also von daher sieht das Verhalten logisch aus.
Die Frage ist also, warum kommen die Daten mit H... an? Mir scheint die Firmware im Stick eine leicht andere zu sein, als Marcolotti heute gepostet hat.
Gesendet von iPhone mit Tapatalk
-
Ok… hab nicht alles gelesen, ja das stimmt ich habe eine andere Firmware auf dem Jeelink als photographix!
Habe mir auch schon gedacht das es vielleicht an dieser liegt
Gesendet von iPhone mit Tapatalk Pro
-
Ok… hab nicht alles gelesen, ja das stimmt ich habe eine andere Firmware auf dem Jeelink als photographix! `
Also poste doch mal den link für deine Firmware, damit photographix diese mal testen kann.
Wenn es dann immer noch Telegramme mit H0… werden, dann muss ich wohl den Adapter erweitern. Aber erstmal würde ich diesen Versuch noch abwarten.
Gesendet von iPhone mit Tapatalk