Navigation

    Logo
    • Register
    • Login
    • Search
    • Recent
    • Tags
    • Unread
    • Categories
    • Unreplied
    • Popular
    • GitHub
    • Docu
    • Hilfe
    1. Home
    2. Deutsch
    3. Error/Bug
    4. [gelöst] Fronius Adapter hat keine Verbindung

    NEWS

    • Neuer Blog: Fotos und Eindrücke aus Solingen

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    [gelöst] Fronius Adapter hat keine Verbindung

    This topic has been deleted. Only users with topic management privileges can see it.
    • T
      Tombir @Glasfaser last edited by

      @glasfaser
      Unbenannt_3.JPG

      Glasfaser 2 Replies Last reply Reply Quote 0
      • Glasfaser
        Glasfaser @Tombir last edited by Glasfaser

        @tombir

        Ja ... genau .. dann auf Debug stellen und den Adapter neu starten

        T 1 Reply Last reply Reply Quote 0
        • Glasfaser
          Glasfaser @Tombir last edited by

          @tombir

          Das ist ja BETA in deinem Screenshot !

          github:	1.1.6
          latest:	1.1.3 for 8 months
          stable:	1.1.3 for 8 months
          
          T 1 Reply Last reply Reply Quote 0
          • T
            Tombir @Glasfaser last edited by

            @glasfaser said in Fronius Adapter hat keine Verbindung:

            Ja ... genau .. dann auf Debug stellen und den Adapter neu starten

            Danke für die Hilfe, habe ich einfach übersehen
            Hier das Log

            fronius.0
            Zeit
            debug
            Nachricht
            
            fronius.0
            2021-11-25 18:55:54.635	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:55:54.634	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:55:54.593	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:55:49.631	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:55:49.629	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:55:49.591	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:55:44.638	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:55:44.637	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:55:44.590	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:55:39.628	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:55:39.627	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:55:39.590	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:55:34.638	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:55:34.636	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:55:34.588	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:55:29.631	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:55:29.629	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:55:29.587	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:55:24.628	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:55:24.627	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:55:24.587	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:55:19.630	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:55:19.629	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:55:19.587	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:55:14.629	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:55:14.628	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:55:14.586	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:55:09.628	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:55:09.626	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:55:09.586	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:55:04.637	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:55:04.635	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:55:04.586	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:54:59.648	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:54:59.648	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:54:59.644	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:54:59.643	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:54:59.576	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:54:59.566	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:54:59.522	info	starting. Version 1.1.6 in /opt/iobroker/node_modules/iobroker.fronius, node: v12.22.4, js-controller: 3.2.16
            
            fronius.0
            2021-11-25 18:54:59.376	debug	statesDB connected
            
            fronius.0
            2021-11-25 18:54:59.375	debug	States connected to redis: 127.0.0.1:9000
            
            fronius.0
            2021-11-25 18:54:59.368	debug	States create User PubSub Client
            
            fronius.0
            2021-11-25 18:54:59.367	debug	States create System PubSub Client
            
            fronius.0
            2021-11-25 18:54:59.359	debug	Redis States: Use Redis connection: 127.0.0.1:9000
            
            fronius.0
            2021-11-25 18:54:59.356	debug	objectDB connected
            
            fronius.0
            2021-11-25 18:54:59.347	debug	Objects connected to redis: 127.0.0.1:9001
            
            fronius.0
            2021-11-25 18:54:59.326	debug	Objects client initialize lua scripts
            
            fronius.0
            2021-11-25 18:54:59.324	debug	Objects create User PubSub Client
            
            fronius.0
            2021-11-25 18:54:59.323	debug	Objects create System PubSub Client
            
            fronius.0
            2021-11-25 18:54:59.321	debug	Objects client ready ... initialize now
            
            fronius.0
            2021-11-25 18:54:59.284	debug	Redis Objects: Use Redis connection: 127.0.0.1:9001
            
            fronius.0
            2021-11-25 18:54:55.508	info	Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
            
            fronius.0
            2021-11-25 18:54:55.507	info	terminating
            
            fronius.0
            2021-11-25 18:54:55.003	info	Got terminate signal TERMINATE_YOURSELF
            
            fronius.0
            2021-11-25 18:54:53.026	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:54:53.026	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:54:53.022	debug	Unable to read data from inverters solarAPI
            
            fronius.0
            2021-11-25 18:54:53.021	debug	Exception thrown in check API: SyntaxError: Unexpected token < in JSON at position 0
            
            fronius.0
            2021-11-25 18:54:52.947	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:54:52.937	debug	System command: /bin/ping -n -w2 -c1 192.168.178.42
            
            fronius.0
            2021-11-25 18:54:52.895	info	starting. Version 1.1.6 in /opt/iobroker/node_modules/iobroker.fronius, node: v12.22.4, js-controller: 3.2.16
            
            fronius.0
            2021-11-25 18:54:52.731	debug	statesDB connected
            
            fronius.0
            2021-11-25 18:54:52.730	debug	States connected to redis: 127.0.0.1:9000
            
            fronius.0
            2021-11-25 18:54:52.722	debug	States create User PubSub Client
            
            fronius.0
            2021-11-25 18:54:52.721	debug	States create System PubSub Client
            
            fronius.0
            2021-11-25 18:54:52.713	debug	Redis States: Use Redis connection: 127.0.0.1:9000
            
            fronius.0
            2021-11-25 18:54:52.711	debug	objectDB connected
            
            fronius.0
            2021-11-25 18:54:52.701	debug	Objects connected to redis: 127.0.0.1:9001
            
            fronius.0
            2021-11-25 18:54:52.689	debug	Objects client initialize lua scripts
            
            fronius.0
            2021-11-25 18:54:52.688	debug	Objects create User PubSub Client
            
            fronius.0
            2021-11-25 18:54:52.686	debug	Objects create System PubSub Client
            
            fronius.0
            2021-11-25 18:54:52.673	debug	Objects client ready ... initialize now
            
            fronius.0
            2021-11-25 18:54:52.636	debug	Redis Objects: Use Redis connection: 127.0.0.1:9001
            
            fronius.0
            2021-11-25 18:54:48.869	info	Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
            
            fronius.0
            2021-11-25 18:54:48.867	info	terminating
            
            fronius.0
            2021-11-25 18:54:48.362	info	Got terminate signal TERMINATE_YOURSELF
            
            1 Reply Last reply Reply Quote 0
            • Glasfaser
              Glasfaser last edited by

              @tombir

              Schau mal hier

              https://github.com/iobroker-community-adapters/ioBroker.fronius/issues/142

              JBSullivan created this issue in iobroker-community-adapters/ioBroker.fronius

              closed Keine Verbindung mehr zum GEN24 - IP ist aber OK #142

              T 1 Reply Last reply Reply Quote 0
              • T
                Tombir @Glasfaser last edited by

                @glasfaser said in Fronius Adapter hat keine Verbindung:

                Das ist ja BETA in deinem Screenshot !

                Da hab ich beim installieren wohl nicht aufgepasst.
                Bis jetzt, und das ist schon einige Monate, ist es aber gut gelaufen.
                Könnte ich einfach downgraden auf 1.1.3, oder verliere ich dabei meine Einstellungen?

                Glasfaser 1 Reply Last reply Reply Quote 0
                • Glasfaser
                  Glasfaser @Tombir last edited by

                  @tombir sagte in Fronius Adapter hat keine Verbindung:

                  auf 1.1.3,

                  Der Fehler kommt nicht von der BETA , das war nur ein Hinweis von mir .

                  1 Reply Last reply Reply Quote 0
                  • T
                    Tombir @Glasfaser last edited by

                    @glasfaser said in Fronius Adapter hat keine Verbindung:

                    Schau mal hier
                    https://github.com/iobroker-community-adapters/ioBroker.fronius/issues/142

                    Danke für den Tipp. Das beschreibt genau mein Problem.

                    Habe mal die Lösung von laguna120 mit einer 2.Instanz versucht.
                    Leider habe ich da genau das gleiche Problem mit der IP.

                    Gerade habe ich gemerkt, dass meine Wallbox auch die Verbindung zum Wechselrichter verloren hat. Auch da kann ich die Verbindung nicht wieder aufbauen.
                    Könnte evtl. auch am Wechselrichter liegen, deshalb werde ich noch einmal einen Neustart versuchen.

                    Glasfaser 1 Reply Last reply Reply Quote 0
                    • Glasfaser
                      Glasfaser @Tombir last edited by Glasfaser

                      @tombir sagte in Fronius Adapter hat keine Verbindung:

                      noch einmal einen Neustart versuchen.

                      Ist ja gerade dunkel ....

                      siehst du die IP nicht in der Fritzbox oder was du so hast .( oben hast du geschrieben Ping geht )

                      meine Wallbox auch die Verbindung zum Wechselrichter verloren

                      die fragt doch den Modbus ab , eventuell etwas am Port verstellt .

                      T 1 Reply Last reply Reply Quote 0
                      • T
                        Tombir @Glasfaser last edited by

                        @glasfaser said in Fronius Adapter hat keine Verbindung:

                        @tombir sagte in Fronius Adapter hat keine Verbindung:

                        noch einmal einen Neustart versuchen.

                        Ist ja gerade dunkel ....
                        siehst du die IP nicht in der Fritzbox oder was du so hast .( oben hast du geschrieben Ping geht )

                        Tadaaaa!!
                        Nach dem Neustart des Wechselrichters funktioniert die Verbindung von IOBroker zum Wechselrichter wieder!
                        Meine Wallbox hat noch immer Verbindungsprobleme, aber das ist nichts Neues. Werde noch einmal einen Neustart per Strom weg-nehmen versuchen.

                        Vielen Dank für deine Hilfe. Habe wieder was dazugelernt.

                        Glasfaser A 2 Replies Last reply Reply Quote 1
                        • Glasfaser
                          Glasfaser @Tombir last edited by

                          @tombir

                          sehr gerne ....

                          Dann setze den Thread auf [gelöst]

                          T 1 Reply Last reply Reply Quote 0
                          • T
                            Tombir @Glasfaser last edited by

                            @glasfaser said in Fronius Adapter hat keine Verbindung:

                            Dann setze den Thread auf [gelöst]

                            Kannst du mir dabei noch einmal helfen?
                            Ich habe keinen Link o.ä. gefunden, wo ich den Thread auf gelöst setzen kann. Auch in der Hilfe keine Hinweise dazu.

                            Glasfaser 1 Reply Last reply Reply Quote 0
                            • Glasfaser
                              Glasfaser @Tombir last edited by Glasfaser

                              @tombir

                              Den Titel ändern mit [gelöst]

                              Im Startbeitrag gehen und bei den 3 Punkten kannst du es ändern
                              .
                              1.JPG
                              .

                              T Glasfaser 2 Replies Last reply Reply Quote 0
                              • T
                                Tombir @Glasfaser last edited by

                                @glasfaser said in Fronius Adapter hat keine Verbindung:

                                m Startbeitrag gehen und bei den 3 Punkten kannst du es ändern
                                .

                                Da hatte ich schon gesucht, aber nur das gefunden:
                                IObroker_Fehler JS-Update_4.JPG

                                1 Reply Last reply Reply Quote 0
                                • Glasfaser
                                  Glasfaser @Glasfaser last edited by Glasfaser

                                  @glasfaser sagte in Fronius Adapter hat keine Verbindung:
                                  Den Titel ändern mit [gelöst]

                                  [gelöst] Fronius Adapter hat keine Verbindung

                                  T 1 Reply Last reply Reply Quote 0
                                  • T
                                    Tombir @Glasfaser last edited by

                                    @glasfaser said in Fronius Adapter hat keine Verbindung:

                                    Den Titel ändern mit [gelöst]

                                    Danke, jetzt habe ich es verstanden.

                                    1 Reply Last reply Reply Quote 0
                                    • A
                                      aftershowman @Tombir last edited by

                                      @tombir
                                      Hatte das selbe Problem.
                                      Auch bei mir, nach Neustart hat sich die Instance wieder verbunden.
                                      Das Problem ist bei mir im Zuge des Firmware Updates des Wechselrichters auf die Version 1.13.13-1 aufgetreten.

                                      1 Reply Last reply Reply Quote 0
                                      • First post
                                        Last post

                                      Support us

                                      ioBroker
                                      Community Adapters
                                      Donate

                                      945
                                      Online

                                      31.9k
                                      Users

                                      80.2k
                                      Topics

                                      1.3m
                                      Posts

                                      3
                                      26
                                      2093
                                      Loading More Posts
                                      • Oldest to Newest
                                      • Newest to Oldest
                                      • Most Votes
                                      Reply
                                      • Reply as topic
                                      Log in to reply
                                      Community
                                      Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                      The ioBroker Community 2014-2023
                                      logo