    Драйвер MegaD-2561

    This topic has been deleted. Only users with topic management privileges can see it.
    • E
      evgeny_nd last edited by

      Сообщение удалено…

      1 Reply Last reply Reply Quote 0
      • H
        Haus last edited by

        @evgeny_nd:

        Можете тогда заодно уточнить как правильно делать:

        1. Есть megad.0 и megadd.0 нужно их разносить на разные порты, т.е. например все драйвера меги328 будут на 8083, а дравйвера меги 2561 на 8084? Т.к. указывая в скрипте "0/" одинаковые значения для разных мег на одном порту опять что-нибудь не будет работать.

        2. Для megadd.1 в поле скрипт нужно прописывать уже "1/"? и т.д.?

        3. Надо ли указывать разные порты для всех имеющихся драйверов: megad.0, megad.1,megad.2 и т.д.

        4. Можно ли название megadd.0 вручную изменить на megad.10, таким образом отпадет необходимость использовать п. 1? `
        1. Все меги могут работать на одном порту, главное чтобы этот порт не использовал кто то иной(например Apache server, Let's Encrypt)

        2. всё верно.

        3. смотри пункт 1.

        4. нет.

        1 Reply Last reply Reply Quote 0
        • E
          evgeny_nd last edited by

          Спасибо. А можно использовать драйвер 2561 для 328й меги?

          1 Reply Last reply Reply Quote 0
          • H
            Haus last edited by

            @evgeny_nd:

            Спасибо. А можно использовать драйвер 2561 для 328й меги? `
            Нет, если коротко MegaD-2561 нету порта P14 также P14, P15 не могут быть ADC и т.д…

            1 Reply Last reply Reply Quote 0
            • W
              wantsoft last edited by

              Скажите а 1-wire список устройств планируется реализовать?

              1 Reply Last reply Reply Quote 0
              • H
                Haus last edited by

                Bluefox , три порта настроены 1WBUS

                Делаю запрос

                ......
                } else if (settings.d == 5) {
                    var port = p;
                    var parts = adapter.config.ip.split(':');
                
                    var options = {
                        host: parts[0],
                        port: parts[1] || 80,
                        path: '/' + adapter.config.password + '/?pt=' + port + '&cmd=list'
                    };
                    adapter.log.debug('1WBUS LIST http://' + options.host + options.path);
                
                    adapter.log.debug('PORT: ' + port);
                
                    http.get(options, function (res) {
                        var data = '';
                        res.on('data', function (chunk) {
                            data += chunk;
                        });
                        res.on('end', function () {
                            adapter.log.debug('PORT: ' + port + ' ' + 'DATA: ' + data);
                        });
                    });
                } else if (settings.d == 6) {
                .....
                
                

                получаю ответ

                megadd.0	2017-03-11 00:19:11.358	debug	PORT: 33 DATA: 30c5b8000000:31.81;32c5b8000000:27.00;31c5b8000000:-15.81
                megadd.0	2017-03-11 00:19:11.061	debug	PORT: 33 DATA: 30c6b8000000:28.31;32c6b8000000:17.12;31c6b8000000:-15.18
                megadd.0	2017-03-11 00:19:10.764	debug	PORT: 33 DATA: 30c9b8000000:-10.56
                
                megadd.0	2017-03-11 00:19:10.525	debug	PORT: 33
                megadd.0	2017-03-11 00:19:10.525	debug	1WBUS LIST http://192.168.1.14/sec/?pt=33&cmd=list
                megadd.0	2017-03-11 00:19:10.525	debug	PORT: 15
                megadd.0	2017-03-11 00:19:10.525	debug	1WBUS LIST http://192.168.1.14/sec/?pt=15&cmd=list
                megadd.0	2017-03-11 00:19:10.525	debug	PORT: 5
                megadd.0	2017-03-11 00:19:10.524	debug	1WBUS LIST http://192.168.1.14/sec/?pt=5&cmd=list
                
                

                почему в ответе PORT всегда последний(33) из запроса, как сделать?

                1 Reply Last reply Reply Quote 0
                • Bluefox
                  Bluefox last edited by

                  @Haus:

                  Bluefox , три порта настроены 1WBUS

                  Делаю запрос

                  ......
                  } else if (settings.d == 5) {
                      var port = p;
                      var parts = adapter.config.ip.split(':');
                  
                      var options = {
                          host: parts[0],
                          port: parts[1] || 80,
                          path: '/' + adapter.config.password + '/?pt=' + port + '&cmd=list'
                      };
                      adapter.log.debug('1WBUS LIST http://' + options.host + options.path);
                  
                      adapter.log.debug('PORT: ' + port);
                                      
                      http.get(options, function (res) {
                          var data = '';
                          res.on('data', function (chunk) {
                              data += chunk;
                          });
                          res.on('end', function () {
                              adapter.log.debug('PORT: ' + port + ' ' + 'DATA: ' + data);
                          });
                      });
                  } else if (settings.d == 6) {
                  .....
                  
                  

                  получаю ответ

                  megadd.0	2017-03-11 00:19:11.358	debug	PORT: 33 DATA: 30c5b8000000:31.81;32c5b8000000:27.00;31c5b8000000:-15.81
                  megadd.0	2017-03-11 00:19:11.061	debug	PORT: 33 DATA: 30c6b8000000:28.31;32c6b8000000:17.12;31c6b8000000:-15.18
                  megadd.0	2017-03-11 00:19:10.764	debug	PORT: 33 DATA: 30c9b8000000:-10.56
                  
                  megadd.0	2017-03-11 00:19:10.525	debug	PORT: 33
                  megadd.0	2017-03-11 00:19:10.525	debug	1WBUS LIST http://192.168.1.14/sec/?pt=33&cmd=list
                  megadd.0	2017-03-11 00:19:10.525	debug	PORT: 15
                  megadd.0	2017-03-11 00:19:10.525	debug	1WBUS LIST http://192.168.1.14/sec/?pt=15&cmd=list
                  megadd.0	2017-03-11 00:19:10.525	debug	PORT: 5
                  megadd.0	2017-03-11 00:19:10.524	debug	1WBUS LIST http://192.168.1.14/sec/?pt=5&cmd=list
                  
                  

                  почему в ответе PORT всегда последний(33) из запроса, как сделать? `
                  Как сделать, что бы по порядку?

                  1 Reply Last reply Reply Quote 0
                  • Bluefox
                    Bluefox last edited by

                    Где можно посмотреть весь код?

                    1 Reply Last reply Reply Quote 0
                    • H
                      Haus last edited by

                      @Bluefox:

                      Где можно посмотреть весь код? `
                      С коментом 1Wire

                      https://github.com/ausHaus/ioBroker.megadd

                      03.05 я тебе в личные писал, там есть пояснение.

                      1 Reply Last reply Reply Quote 0
                      • Bluefox
                        Bluefox last edited by

                        @Haus:

                        @Bluefox:

                        Где можно посмотреть весь код? `
                        С коментом 1Wire

                        https://github.com/ausHaus/ioBroker.megadd

                        03.05 я тебе в личные писал, там есть пояснение. `
                        48_main.js

                        1 Reply Last reply Reply Quote 0
                        • Bluefox
                          Bluefox last edited by

                          Работает?

                          1 Reply Last reply Reply Quote 0
                          • H
                            Haus last edited by

                            @Bluefox:

                            Работает? `

                            megadd.0	2017-03-13 18:49:57.227	error	at process._tickCallback (node.js:425:17)
                            megadd.0	2017-03-13 18:49:57.227	error	at nextTickCallbackWith2Args (node.js:511:9)
                            megadd.0	2017-03-13 18:49:57.227	error	at endReadableNT (_stream_readable.js:923:12)
                            megadd.0	2017-03-13 18:49:57.227	error	at IncomingMessage.emit (events.js:166:7)
                            megadd.0	2017-03-13 18:49:57.227	error	at emitNone (events.js:72:20)
                            megadd.0	2017-03-13 18:49:57.227	error	at IncomingMessage. (/opt/iobroker/node_modules/iobroker.megadd/main.js:130:25)
                            megadd.0	2017-03-13 18:49:57.227	error	at /opt/iobroker/node_modules/iobroker.megadd/main.js:816:23
                            megadd.0	2017-03-13 18:49:57.227	error	at /opt/iobroker/node_modules/iobroker.megadd/main.js:1151:25
                            megadd.0	2017-03-13 18:49:57.227	error	at getPortStateW (/opt/iobroker/node_modules/iobroker.megadd/main.js:777:20)
                            megadd.0	2017-03-13 18:49:57.227	error	TypeError: ip.split is not a function
                            megadd.0	2017-03-13 18:49:57.217	error	uncaught exception: ip.split is not a function
                            
                            1 Reply Last reply Reply Quote 0
                            • Bluefox
                              Bluefox last edited by

                              Я тебе pull request прислал

                              1 Reply Last reply Reply Quote 0
                              • H
                                Haus last edited by

                                @Bluefox:

                                Я тебе pull request прислал `
                                Дублирует запрос, соответственно и ответ. РЕШЕНО!!!

                                ! megadd.0 2017-03-14 06:41:43.232 debug inMem message megadd.0.* megadd.0.p33_P33_31c5b8000000
                                ! megadd.0 2017-03-14 06:41:43.232 debug inMem message megadd.0.* megadd.0.p33_P33_32c5b8000000
                                ! megadd.0 2017-03-14 06:41:43.218 debug inMem message megadd.0.* megadd.0.p33_P33_30c5b8000000
                                ! megadd.0 2017-03-14 06:41:43.202 debug detected new value on port [33_31c5b8000000]: -15.81
                                ! megadd.0 2017-03-14 06:41:43.201 debug detected new value on port [33_32c5b8000000]: 27
                                ! megadd.0 2017-03-14 06:41:43.201 debug detected new value on port [33_30c5b8000000]: 31.81
                                ! megadd.0 2017-03-14 06:41:43.201 debug Response: 30c5b8000000:31.81;32c5b8000000:27.00;31c5b8000000:-15.81
                                ! megadd.0 2017-03-14 06:41:42.982 debug inMem message megadd.0.* megadd.0.p15_P15_31c6b8000000
                                ! megadd.0 2017-03-14 06:41:42.982 debug inMem message megadd.0.* megadd.0.p15_P15_32c6b8000000
                                ! megadd.0 2017-03-14 06:41:42.982 debug inMem message megadd.0.* megadd.0.p15_P15_30c6b8000000
                                ! megadd.0 2017-03-14 06:41:42.982 debug detected new value on port [15_31c6b8000000]: -15.18
                                ! megadd.0 2017-03-14 06:41:42.981 debug detected new value on port [15_32c6b8000000]: 17.12
                                ! megadd.0 2017-03-14 06:41:42.981 debug detected new value on port [15_30c6b8000000]: 28.31
                                ! megadd.0 2017-03-14 06:41:42.980 debug Response: 30c6b8000000:28.31;32c6b8000000:17.12;31c6b8000000:-15.18
                                ! megadd.0 2017-03-14 06:41:42.671 debug Response: 30c9b8000000:-10.56
                                ! megadd.0 2017-03-14 06:41:42.576 debug inMem message megadd.0.* megadd.0.p33_P33_31c5b8000000
                                ! megadd.0 2017-03-14 06:41:42.575 debug inMem message megadd.0.* megadd.0.p33_P33_32c5b8000000
                                ! megadd.0 2017-03-14 06:41:42.556 debug inMem message megadd.0.* megadd.0.p33_P33_30c5b8000000
                                ! megadd.0 2017-03-14 06:41:42.555 debug detected new value on port [33_31c5b8000000]: -15.81
                                ! megadd.0 2017-03-14 06:41:42.555 debug detected new value on port [33_32c5b8000000]: 27
                                ! megadd.0 2017-03-14 06:41:42.555 debug detected new value on port [33_30c5b8000000]: 31.81
                                ! megadd.0 2017-03-14 06:41:42.554 debug Response: 30c5b8000000:31.81;32c5b8000000:27.00;31c5b8000000:-15.81
                                ! megadd.0 2017-03-14 06:41:42.344 debug inMem message megadd.0.* megadd.0.p15_P15_31c6b8000000
                                ! megadd.0 2017-03-14 06:41:42.343 debug inMem message megadd.0.* megadd.0.p15_P15_32c6b8000000
                                ! megadd.0 2017-03-14 06:41:42.342 debug inMem message megadd.0.* megadd.0.p15_P15_30c6b8000000
                                ! megadd.0 2017-03-14 06:41:42.342 debug detected new value on port [15_31c6b8000000]: -15.18
                                ! megadd.0 2017-03-14 06:41:42.342 debug detected new value on port [15_32c6b8000000]: 17.12
                                ! megadd.0 2017-03-14 06:41:42.341 debug detected new value on port [15_30c6b8000000]: 28.31
                                ! megadd.0 2017-03-14 06:41:42.340 debug Response: 30c6b8000000:28.31;32c6b8000000:17.12;31c6b8000000:-15.18
                                ! megadd.0 2017-03-14 06:41:42.118 debug Response: 30c9b8000000:-10.56
                                ! megadd.0 2017-03-14 06:41:41.890 debug getPortStateW http://192.168.1.14/sec/?pt=33&cmd=list
                                ! megadd.0 2017-03-14 06:41:41.890 debug getPortStateW http://192.168.1.14/sec/?pt=15&cmd=list
                                ! megadd.0 2017-03-14 06:41:41.890 debug getPortStateW http://192.168.1.14/sec/?pt=5&cmd=list
                                ! megadd.0 2017-03-14 06:41:41.889 debug Response: temp:24.00;OFF/0;OFF/0;;OFF;;temp:0.00/hum:0.00;OFF/OFF;NA/NA;OFF;0;0;0;255;ON;;OFF;temp:0.04/press:1.76;OFF/0;OFF/0;temp:6.00/hum:76.00;temp:0.00/hum:0.00;OFF;;OFF;;;OFF;OFF;ON;;OFF;temp:-2
                                ! megadd.0 2017-03-14 06:41:39.658 debug getPortStateW http://192.168.1.14/sec/?pt=33&cmd=list
                                ! megadd.0 2017-03-14 06:41:39.658 debug getPortStateW http://192.168.1.14/sec/?pt=15&cmd=list
                                ! megadd.0 2017-03-14 06:41:39.658 debug getPortStateW http://192.168.1.14/sec/?pt=5&cmd=list
                                ! megadd.0 2017-03-14 06:41:39.657 debug Response: temp:24.00;OFF/0;OFF/0;;OFF;;temp:0.00/hum:0.00;OFF/OFF;NA/NA;OFF;0;0;0;255;ON;;OFF;temp:0.04/press:1.76;OFF/0;OFF/0;temp:6.00/hum:76.00;temp:0.00/hum:0.00;OFF;;OFF;;;OFF;OFF;ON;;OFF;temp:-2
                                ! megadd.0 2017-03-14 06:41:37.758 debug getPortState http://192.168.1.14/sec/?cmd=all
                                P.S. Лишние строки затесались 🙂

                                Ну и самое главное в чем был вопрос, как создать эти порты. p5_P5_30c9b8000000, p15_P15_30c6b8000000, p15_P15_31c6b8000000, ….p33P33_..

                                ! if (settings.pty == 3) {
                                ! obj.common.write = false;
                                ! obj.common.read = true;
                                ! obj.common.def = 0;
                                ! obj.common.type = 'number';
                                ! if (settings.d == 1 || settings.d == 2 || settings.d == 3) {
                                ! …..
                                ! } else if (settings.d == 5) { // 1Wire
                                ! obj.common.min = -30;
                                ! obj.common.max = 30;
                                ! obj.common.unit = '°C';
                                ! obj.common.desc = 'P' + p + ' - temperature';
                                ! obj.common.type = 'number';
                                ! if (!obj.common.role) obj.common.role = 'value.temperature';
                                ! .....
                                Кое что подправил

                                ! if (val !== _ports[_port].value || _ports[_port].q !== q) {
                                ! adapter.log.debug('VAL :' + val + ' ' + 'PORT VAL :' + _ports[_port].value);
                                ! _ports[_port].oldValue = _ports[_port].value;
                                ! if (_ports[_port].pty == 3 && _ports[_port].d == 5) {
                                ! adapter.log.debug('detected new value on port [' + port + '' + id[0] + ']: ' + val);
                                ! ///adapter.setState(_ports[port].id + '' + id[0], {val: value, ack: true, q: q});
                                ! adapter.setState(_ports[port].id + '' + id[0], {val: val, ack: true, q: q}); //haus
                                ! }
                                ! _ports[_port].value = val;
                                ! _ports[_port].q = q;
                                ! }
                                Вбил руками порты megadd.0.p33_P33_32c5b8000000, …... Неправильно определяет if (val !== _ports[_port].value || _ports[_port].q !== q) { если больше одного датчика

                                ! megadd.0 2017-03-14 17:21:29.678 debug inMem message megadd.0.* megadd.0.p33_P33_31c5b8000000
                                ! megadd.0 2017-03-14 17:21:29.677 debug inMem message megadd.0.* megadd.0.p33_P33_32c5b8000000
                                ! megadd.0 2017-03-14 17:21:29.665 debug inMem message megadd.0.* megadd.0.p33_P33_30c5b8000000
                                ! megadd.0 2017-03-14 17:21:29.664 debug detected new value on port [33_31c5b8000000]: -17.37
                                ! megadd.0 2017-03-14 17:21:29.663 debug VAL :-17.37 PORT VAL :27
                                ! megadd.0 2017-03-14 17:21:29.663 debug detected new value on port [33_32c5b8000000]: 27
                                ! megadd.0 2017-03-14 17:21:29.663 debug VAL :27 PORT VAL :31.81
                                ! megadd.0 2017-03-14 17:21:29.662 debug detected new value on port [33_30c5b8000000]: 31.81
                                ! megadd.0 2017-03-14 17:21:29.662 debug VAL :31.81 PORT VAL :-17.37
                                ! megadd.0 2017-03-14 17:21:29.661 debug Response: 30c5b8000000:31.81;32c5b8000000:27.00;31c5b8000000:-17.37
                                Иногда MegaD на запрос http://192.168.1.14/sec/?pt=33&cmd=list может вернуть "busy" если шина занята конвертацией, здесь главное чтобы драйвер не парсил этот ответ или как вариант повторил запрос скажем через 5-10 секунд.

                                ! megadd.0 2017-03-14 09:45:38.692 debug Response: busy
                                ! megadd.0 2017-03-14 09:45:38.611 debug Response: busy
                                ! megadd.0 2017-03-14 09:45:38.600 debug Response: busy
                                ! megadd.0 2017-03-14 09:45:32.537 debug getPortStateW http://192.168.1.14/sec/?pt=33&cmd=list
                                ! megadd.0 2017-03-14 09:45:32.536 debug getPortStateW http://192.168.1.14/sec/?pt=15&cmd=list
                                ! megadd.0 2017-03-14 09:45:32.534 debug getPortStateW http://192.168.1.14/sec/?pt=5&cmd=list

                                1 Reply Last reply Reply Quote 0
                                • P
                                  Pooh last edited by

                                  Помогите, плз, пошагово настроить мегу2561 и драйвер, делал по аналогии с драйвером мега328 (который работает отлично), не получилось - состояние портов меняется раз в 30 сек, а не по факту нажатия кнопки

                                  кнопка на порту 18, реле на порту 25. с каждым нажатием кнопки меняем состояние реле

                                  1 Reply Last reply Reply Quote 0
                                  • H
                                    Haus last edited by

                                    @Pooh:

                                    Помогите, плз, пошагово настроить мегу2561 и драйвер, делал по аналогии с драйвером мега328 (который работает отлично), не получилось - состояние портов меняется раз в 30 сек, а не по факту нажатия кнопки

                                    кнопка на порту 18, реле на порту 25. с каждым нажатием кнопки меняем состояние реле `
                                    Настройки отличаются от Megad-328. В принципе достаточно считать настройки с Megad-2561(если настроен) и после этого записать настройки в Megad-2561 (что бы прописался сервер и инстанция(скрипт)).

                                    Пример если кнопка
                                    443_megad_config.png
                                    443_megadd_port.png
                                    443_megadd_admin.png
                                    script

                                    on({id: 'megadd.0.p1_P1', change: 'any'}, function (obj) {    
                                        if (obj.newState.val === true && getState('megadd.0.p24_P24').val === false) {
                                            setState('megadd.0.p24_P24', true);
                                        } else if (obj.newState.val === true && getState('megadd.0.p24_P24').val === true) {
                                            setState('megadd.0.p24_P24', false);
                                        }
                                    });
                                    
                                    1 Reply Last reply Reply Quote 0
                                    • P
                                      Pooh last edited by

                                      @Haus:

                                      ..В принципе достаточно считать настройки с Megad-2561(если настроен) и после этого записать настройки в Megad-2561 (что бы прописался сервер и инстанция(скрипт)).. `
                                      НИФИГА

                                      Два вечера бился практически методом тыка

                                      настроил mega2561: каждый вход "mod P с галочкой". при этом без сервера выполняется автономная команда

                                      прочитал драйвером настройки.

                                      изменил в драйвере режим входов на "при изменении" (после считывания было "при замыкании")

                                      сохранил (без сохранения в сам мегад3561!)

                                      скрипт типа:

                                      on('megadd.0.p2_P2', function (obj) {
                                          if (obj.newState.val === true && getState('megadd.0.p9_P9').val === false) {
                                              setState ('megadd.0.p9_P9', true);
                                          }else if(obj.newState.val === true && getState('megadd.0.p9_P9').val === true){
                                              setState ('megadd.0.p9_P9', false);
                                          }
                                      });
                                      
                                      

                                      ВУАЛЯ

                                      1 Reply Last reply Reply Quote 0
                                      • H
                                        Haus last edited by

                                        @Pooh:

                                        @Haus:

                                        ..В принципе достаточно считать настройки с Megad-2561(если настроен) и после этого записать настройки в Megad-2561 (что бы прописался сервер и инстанция(скрипт)).. НИФИГА
                                        ????? что не так?
                                        @Pooh:

                                        Два вечера бился практически методом тыка

                                        настроил mega2561: каждый вход "mod P с галочкой". при этом без сервера выполняется автономная команда

                                        прочитал драйвером настройки. `
                                        Считал драйвер настройки правильно?
                                        @Pooh:

                                        изменил в драйвере режим входов на "при изменении" (после считывания было "при замыкании")

                                        сохранил (без сохранения в сам мегад3561!) `
                                        Драйвер MegaD-2561, как я писал выше отличается от MegaD-328. При считывание конфига в настройках драйвера менять ничего не надо, а если поменял то надо записать изменения в MegaD-2561. ТО ЕСТЬ ИЗ ДРАЙВЕРА МОЖНО ПОМЕНЯТЬ ВСЕ НАСТРОЙКИ MegaD-2561, НЕ ИСПОЛЬЗУЯ WEB MegaD-2561.

                                        1 Reply Last reply Reply Quote 0
                                        • P
                                          Pooh last edited by

                                          у меня в драйвере нет "текущая версия прошивки… доступная версия прошивки..."

                                          v0.2.0

                                          1 Reply Last reply Reply Quote 0
                                          • P
                                            Pooh last edited by

                                            @Haus:

                                            ..????? что не так?.. `
                                            думаю драйвером не учитывается, что "Флажок (чекбокс) справа от поля Mode указывает, что при наличии сервера, устройство отправляет на сервер сообщения всегда в режиме P&R, а при его отсутствии Action выполняется только в том режиме, который установлен в Mode." (http://ab-log.ru/smart-house/ethernet/megad-2561)

                                            т.е. если установить в модуле режим P&R и считать драйвером, то все хорошо, пока сервер работает. если установить в модуле режим P с галочкой и считать драйвером, то все хорошо, пока сервер (драйвер) не работает.

                                            Счастье наступает, когда в модуле режим входов установлен в P с галочкой, конфиг считан драйвером и режим (в драйвере) изменен на "при изменении"

                                            запись параметров в модуль из драйвера результатов не дает, ибо драйвер четко записывает режим P&R, при котором не работает автономный режим…

                                            и да, считывается/записывается один-в-один

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            794