      Hallo,

      leider krieg ich den Adapter Smartmeter nicht zum laufen. Ich hab grad erst mit der Installation von iobroker (und influxDB) auf einem Raspi per Docker compose begonnen:

      version: '3.8'
      
      # More info at https://github.com/pi-hole/docker-pi-hole/ and https://docs.pi-hole.net/
      services:
        influxdb:
          container_name: influxdb
          image: influxdb:1.8
          hostname: influxDB
          ports:
            - "8083:8083"
            - "8086:8086"
            - "8090:8090"
          environment:
            - INFLUXDB_DB=sensors
            - INFLUXDB_USER=xxx
            - INFLUXDB_USER_PASSWORD=xxx
          # Volumes store your data between container upgrades
          volumes:
            - ./influxdb-storage/:/var/lib/influxdb
          restart: always
          network_mode: bridge
      
        grafana:
          image: grafana/grafana:latest
          container_name: grafana
          hostname: grafana
          ports:
            - "3000:3000"
          depends_on:
            - influxdb
          volumes:
            - ./grafana-storage:/var/lib/grafana
          restart: always
          network_mode: bridge
      
        ioBroker:
          image: buanet/iobroker:latest-v5
          container_name: ioBroker
          hostname: ioBroker
          ports:
            - "8081:8081"
          depends_on:
            - influxdb
          environment:
            TZ: 'Europe/Berlin'
          volumes:
            - ./iobroker-storage:/opt/iobroker
          restart: always
          network_mode: bridge
      

      Der Lesekopf läuft und zeigt mir auch was an:
      sml.png

      Angeblich ist "1b 1b 1b ..." der Beginn einer neuen Nachricht, also vermute ich, dass die Hardware funktioniert.

      Das Log gibt mir leider keinen Aufschluss:

      2021-12-22 14:22:27.321 - debug: smartmeter.0 (1339) Error: No or too long answer from Serial Device after last request.
      2021-12-22 14:24:57.325 - warn: smartmeter.0 (1339) No or too long answer from Serial Device after last request.
      2021-12-22 14:24:57.326 - debug: smartmeter.0 (1339) Error: No or too long answer from Serial Device after last request.
      2021-12-22 14:27:27.329 - warn: smartmeter.0 (1339) No or too long answer from Serial Device after last request.
      2021-12-22 14:27:27.330 - debug: smartmeter.0 (1339) Error: No or too long answer from Serial Device after last request.
      2021-12-22 14:29:27.824 - silly: smartmeter.0 (1339) States system redis pmessage io.messagebox.system.adapter.smartmeter.0/io.messagebox.system.adapter.smartmeter.0:{"command":"listUart","message":null,"from":"system.adapter.admin.0","callback":{"message":null,"id":47,"ack":false,"time":1640179767817},"_id":25487976}
      2021-12-22 14:29:27.825 - debug: smartmeter.0 (1339) Message received = {"command":"listUart","message":null,"from":"system.adapter.admin.0","callback":{"message":null,"id":47,"ack":false,"time":1640179767817},"_id":25487976}
      2021-12-22 14:29:28.020 - info: smartmeter.0 (1339) List of port: [{"path":"/dev/ttyUSB0"},{"path":"/dev/ttyAMA0"}]
      2021-12-22 14:29:28.022 - debug: smartmeter.0 (1339) sendTo "listUart" to system.adapter.admin.0 from system.adapter.smartmeter.0
      2021-12-22 14:29:57.333 - warn: smartmeter.0 (1339) No or too long answer from Serial Device after last request.
      2021-12-22 14:29:57.334 - debug: smartmeter.0 (1339) Error: No or too long answer from Serial Device after last request.
      2021-12-22 14:30:18.501 - info: host.ioBroker stopInstance system.adapter.smartmeter.0 (force=false, process=true)
      2021-12-22 14:30:18.518 - silly: smartmeter.0 (1339) States system redis pmessage system.adapter.smartmeter.0.sigKill/system.adapter.smartmeter.0.sigKill:{"val":-1,"ack":false,"ts":1640179818515,"q":0,"from":"system.host.ioBroker","lc":1640179818515}
      2021-12-22 14:30:18.520 - info: host.ioBroker stopInstance system.adapter.smartmeter.0 send kill signal
      2021-12-22 14:30:18.519 - info: smartmeter.0 (1339) Got terminate signal TERMINATE_YOURSELF
      2021-12-22 14:30:18.521 - info: smartmeter.0 (1339) terminating
      2021-12-22 14:30:18.523 - debug: smartmeter.0 (1339) Plugin sentry destroyed
      2021-12-22 14:30:18.524 - info: smartmeter.0 (1339) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
      2021-12-22 14:30:19.069 - info: host.ioBroker instance system.adapter.smartmeter.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
      2021-12-22 14:30:21.625 - info: host.ioBroker instance system.adapter.smartmeter.0 started with pid 1884
      2021-12-22 14:30:23.025 - debug: smartmeter.0 (1884) Redis Objects: Use Redis connection: 127.0.0.1:9001
      2021-12-22 14:30:23.065 - debug: smartmeter.0 (1884) Objects client ready ... initialize now
      2021-12-22 14:30:23.068 - debug: smartmeter.0 (1884) Objects create System PubSub Client
      2021-12-22 14:30:23.069 - debug: smartmeter.0 (1884) Objects create User PubSub Client
      2021-12-22 14:30:23.070 - debug: smartmeter.0 (1884) Objects client initialize lua scripts
      2021-12-22 14:30:23.093 - debug: smartmeter.0 (1884) Objects connected to redis: 127.0.0.1:9001
      2021-12-22 14:30:23.096 - silly: smartmeter.0 (1884) redis psubscribe cfg.o.system.user.*
      2021-12-22 14:30:23.101 - debug: smartmeter.0 (1884) objectDB connected
      2021-12-22 14:30:23.104 - debug: smartmeter.0 (1884) Redis States: Use Redis connection: 127.0.0.1:9000
      2021-12-22 14:30:23.111 - debug: smartmeter.0 (1884) States create System PubSub Client
      2021-12-22 14:30:23.112 - debug: smartmeter.0 (1884) States create User PubSub Client
      2021-12-22 14:30:23.119 - debug: smartmeter.0 (1884) States connected to redis: 127.0.0.1:9000
      2021-12-22 14:30:23.120 - debug: smartmeter.0 (1884) statesDB connected
      2021-12-22 14:30:23.245 - debug: smartmeter.0 (1884) Plugin sentry Initialize Plugin (enabled=true)
      2021-12-22 14:30:23.453 - info: smartmeter.0 (1884) starting. Version 3.2.1 in /opt/iobroker/node_modules/iobroker.smartmeter, node: v12.22.8, js-controller: 3.3.21
      2021-12-22 14:30:23.500 - debug: smartmeter.0 (1884) SmartmeterObis options: {"debug":0,"protocol":"SmlProtocol","transport":"SerialResponseTransport","requestInterval":"30","anotherQueryDelay":"1000","transportSerialPort":"/dev/ttyUSB0","transportSerialBaudrate":9600,"transportSerialDataBits":8,"transportSerialStopBits":1,"transportSerialParity":"none","transportSerialMessageTimeout":null,"protocolSmlIgnoreInvalidCRC":false}
      2021-12-22 14:30:23.567 - silly: smartmeter.0 (1884) States system redis pmessage system.adapter.smartmeter.0.logLevel/system.adapter.smartmeter.0.logLevel:{"val":"silly","ack":true,"ts":1640179823508,"q":0,"from":"system.adapter.smartmeter.0","lc":1640138878782}
      2021-12-22 14:30:23.657 - debug: smartmeter.0 (1884) connected set to false
      2021-12-22 14:32:23.514 - warn: smartmeter.0 (1884) No or too long answer from Serial Device after last request.
      2021-12-22 14:32:23.516 - debug: smartmeter.0 (1884) Error: No or too long answer from Serial Device after last request.
      2021-12-22 14:34:53.521 - warn: smartmeter.0 (1884) No or too long answer from Serial Device after last request.
      2021-12-22 14:34:53.523 - debug: smartmeter.0 (1884) Error: No or too long answer from Serial Device after last request.
      2021-12-22 14:37:23.525 - warn: smartmeter.0 (1884) No or too long answer from Serial Device after last request.
      2021-12-22 14:37:23.527 - debug: smartmeter.0 (1884) Error: No or too long answer from Serial Device after last request.
      2021-12-22 14:39:53.530 - warn: smartmeter.0 (1884) No or too long answer from Serial Device after last request.
      2021-12-22 14:39:53.530 - debug: smartmeter.0 (1884) Error: No or too long answer from Serial Device after last request.
      2021-12-22 14:42:23.533 - warn: smartmeter.0 (1884) No or too long answer from Serial Device after last request.
      2021-12-22 14:42:23.534 - debug: smartmeter.0 (1884) Error: No or too long answer from Serial Device after last request.
      

      Laut Handbuch meines Stromzählers (EMH eHZ-KW8...) sollten auch die Einstellungen passen:
      conf.png

      Als Hardware hab ich einen vzLogger-kompatiblen TTL-Lesekopf an einem PL2303 USB-Seriell Adapter.
      Woran können meine Probleme liegen?

      Homoran 3 Replies Last reply Reply Quote 0
      • Homoran
        Homoran Global Moderator Administrators @mich last edited by Homoran

        @mich sagte in Adapter "smartmeter":

        eider krieg ich den Adapter Smartmeter nicht zum laufen

        Bitte keine Screenshots!
        Alles was geht als Text in Code-Tags

        Ist das DOCKER??
        liest du ZEITGLEICH über die Konsole aus?

        M 1 Reply Last reply Reply Quote 0
        • M
          mich @Homoran last edited by

          @homoran
          ja, läuft im Docker und das Auslesen ist aus der Console des Host. Zeitgleich war das nicht und auch mehrere Reboots dazwischen, falls durch das Auslesen der Port geöffnet bleibt.

          K 1 Reply Last reply Reply Quote 0
          • K
            klassisch Most Active @mich last edited by

            @mich Adapter auf "debug" stellen und dann bitte das log vom Start posten.

            M 1 Reply Last reply Reply Quote 0
            • M
              mich @klassisch last edited by

              @klassisch

              2021-12-22 15:16:25.047 - info: host.ioBroker "system.adapter.smartmeter.0" enabled
              2021-12-22 15:16:25.120 - info: host.ioBroker instance system.adapter.smartmeter.0 started with pid 4135
              2021-12-22 15:16:26.549 - debug: smartmeter.0 (4135) Redis Objects: Use Redis connection: 127.0.0.1:9001
              2021-12-22 15:16:26.585 - debug: smartmeter.0 (4135) Objects client ready ... initialize now
              2021-12-22 15:16:26.587 - debug: smartmeter.0 (4135) Objects create System PubSub Client
              2021-12-22 15:16:26.589 - debug: smartmeter.0 (4135) Objects create User PubSub Client
              2021-12-22 15:16:26.590 - debug: smartmeter.0 (4135) Objects client initialize lua scripts
              2021-12-22 15:16:26.612 - debug: smartmeter.0 (4135) Objects connected to redis: 127.0.0.1:9001
              2021-12-22 15:16:26.620 - debug: smartmeter.0 (4135) objectDB connected
              2021-12-22 15:16:26.622 - debug: smartmeter.0 (4135) Redis States: Use Redis connection: 127.0.0.1:9000
              2021-12-22 15:16:26.630 - debug: smartmeter.0 (4135) States create System PubSub Client
              2021-12-22 15:16:26.631 - debug: smartmeter.0 (4135) States create User PubSub Client
              2021-12-22 15:16:26.637 - debug: smartmeter.0 (4135) States connected to redis: 127.0.0.1:9000
              2021-12-22 15:16:26.638 - debug: smartmeter.0 (4135) statesDB connected
              2021-12-22 15:16:26.733 - debug: smartmeter.0 (4135) Plugin sentry Initialize Plugin (enabled=true)
              2021-12-22 15:16:26.952 - info: smartmeter.0 (4135) starting. Version 3.2.1 in /opt/iobroker/node_modules/iobroker.smartmeter, node: v12.22.8, js-controller: 3.3.21
              2021-12-22 15:16:26.986 - debug: smartmeter.0 (4135) SmartmeterObis options: {"debug":2,"protocol":"SmlProtocol","transport":"SerialResponseTransport","requestInterval":"30","anotherQueryDelay":"1000","transportSerialPort":"/dev/ttyUSB0","transportSerialBaudrate":9600,"transportSerialDataBits":8,"transportSerialStopBits":1,"transportSerialParity":"none","transportSerialMessageTimeout":null,"protocolSmlIgnoreInvalidCRC":false}
              2021-12-22 15:16:26.989 - debug: smartmeter.0 (4135) CREATE SERIALPORT: 9600 8 1 none
              2021-12-22 15:16:26.996 - debug: smartmeter.0 (4135) SET MESSAGE TIMEOUT TIMER: 120000
              2021-12-22 15:16:27.015 - debug: smartmeter.0 (4135) connected set to false
              
              K apollon77 2 Replies Last reply Reply Quote 0
              • K
                klassisch Most Active @mich last edited by

                @mich da sehe ich aber noch keine Fehlermeldung oder timeout meldung oder ein Einlesen von Daten. Ist das das ganze log?

                Homoran 1 Reply Last reply Reply Quote 0
                • Homoran
                  Homoran Global Moderator Administrators @klassisch last edited by

                  @klassisch sagte in Adapter "smartmeter":

                  oder timeout meldung oder ein Einlesen von Daten.

                  das müsste ggf. nach einiger Zeit noch kommen.
                  Hier ist nix

                  1 Reply Last reply Reply Quote 0
                  • Homoran
                    Homoran Global Moderator Administrators @mich last edited by

                    @mich sagte in Adapter "smartmeter":

                    Laut Handbuch meines Stromzählers (EMH eHZ-KW8...) sollten auch die Einstellungen passen:

                    was steht denn da drin?

                    1 Reply Last reply Reply Quote 0
                    • apollon77
                      apollon77 @mich last edited by Homoran

                      @mich Da kommt nix rein ... aber du hast nicht an der Shell noch die Ausgabe laufen oder? Dann ist ggf der Port geblockt

                      1 Reply Last reply Reply Quote 0
                      • Homoran
                        Homoran Global Moderator Administrators @mich last edited by

                        @mich sagte in Adapter "smartmeter":

                        sollten auch die Einstellungen passen:

                        bist du sicher, das /dev/USB0 korrekt ist?
                        hast du nichts wo deine Hardware mit drin steht zur Verfügung?

                        1 Reply Last reply Reply Quote 0
                        • M
                          mich last edited by

                          Ich glaub, ich hab mein Problem gefunden:
                          https://smarthome.buanet.de/2020/02/usb-devices-im-iobroker-docker-container-nutzen/

                          Homoran 1 Reply Last reply Reply Quote 0
                          • Homoran
                            Homoran Global Moderator Administrators @mich last edited by

                            @mich sagte in Adapter "smartmeter":

                            Ich glaub, ich hab mein Problem gefunden:

                            deswegen frug ich nach DOCKER

                            apollon77 1 Reply Last reply Reply Quote 0
                            • apollon77
                              apollon77 @Homoran last edited by

                              @homoran du frugst? 🙂

                              1 Reply Last reply Reply Quote 1
                              • M
                                marsmännchen last edited by

                                Hallo,
                                weiss vielleicht jemand ob es möglich ist im Netz Burgenland (Österreich) einen Landis+Gyr E450 mit dem Hinchi-USB und Smartmeteradapter auszulesen?
                                Hat das jemand im Einsatz?
                                Ich hab bis jetzt noch keine funktionierende Einstellung gefunden.
                                Die opt. Schnittstelle ist frei, und ich bekomme mit minicom auch alle 5sec. allerhand Daten. Aber mein Adapter bleibt bei "Verbunden mit Gerät oder Dienst" immer rot.
                                MfG
                                Patrick

                                Homoran A 2 Replies Last reply Reply Quote 0
                                • Homoran
                                  Homoran Global Moderator Administrators @marsmännchen last edited by

                                  @marsmännchen sagte in Adapter "smartmeter":

                                  im Netz Burgenland (Österreich)

                                  das klingt nach verschlüsselter Übertragung
                                  Das kann der Adapter nicht

                                  M 1 Reply Last reply Reply Quote 1
                                  • M
                                    marsmännchen @Homoran last edited by

                                    @homoran JA GENAU! Danke!
                                    Die verschlüsseln. Daran liegt es? Na wenigstens liege ich mit meiner Vermutung richtig. Dann kann ich schon mal aufhören den Adapter zu quälen.
                                    Ich habe den Energielieferanten angeschrieben ob er die Verschlüsselung deaktivieren kann.
                                    Mal sehen. In einem anderen Forum wird behauptet das es möglich ist.
                                    Vielen dank!! Frohe Feiertage

                                    Homoran A 2 Replies Last reply Reply Quote 0
                                    • Homoran
                                      Homoran Global Moderator Administrators @marsmännchen last edited by

                                      @marsmännchen sagte in Adapter "smartmeter":

                                      In einem anderen Forum wird behauptet das es möglich ist.

                                      auch hier 🙂
                                      da gab es irgendeinen Workaround - musst mal suchen (daher weiss ich es ja mirt der Ösi-Verschlüsselung)

                                      1 Reply Last reply Reply Quote 0
                                      • H
                                        hotwire last edited by

                                        Hallo zusammen,
                                        ich habe Dank großer Unterstützung eines Freunds IOBroker mit dem adapter Smartmeter auf einem Rasperry 4 laufen.

                                        Zweck der Aktion ist, endlichen die Ursache der hohen Grundlast in meinem Elternhaus zu finden.
                                        Es läuft eigentlich auf Anhieb, allerdings wird mir der Aktualwert der Leistung nicht übertragen.

                                        Der Zweirichtungszähler ist ein Itron 3.HZ-AC-D1-A1 Die Zählerpin ist eingegeben, und die Pinabfrage ausgeschaltet.
                                        Im Display wird nun der Aktualwert der Leistung in Zeile 2 dauerhaft angezeigt.

                                        Wie kann ich nun die Smartmeterinstanz so konfigurieren, dass mir diese Daten geloggt werden?
                                        smartmeterinstanz.PNG

                                        K 1 Reply Last reply Reply Quote 0
                                        • K
                                          klassisch Most Active @hotwire last edited by

                                          @hotwire Bezieht sich die Frage generell auf Logging in ioBroker oder auf den Smartmeter-Adapter?
                                          Der Smartmeteradapter zeigt in den Objekten alles an, was vom Zähler kommt. Da kann und muß man nichts einstellen.
                                          Wenn etwas nicht angezeigt wird, dann schickt es der Zähler nicht.
                                          also nochmals die Anleitung vom Zähler und vom Betreiber durchackern. Vielleicht muß man da zusätzlich noch was einschalten bei diesem Blinkcode-Menue.
                                          Ich habe auch einen itron, allerdings nur Bezug, kein Zweirichtung
                                          Da kommt die Momentanleistung unter

                                          smartmeter.0.1-0:16_7_0__255
                                          
                                          Homoran 1 Reply Last reply Reply Quote 1
                                          • Homoran
                                            Homoran Global Moderator Administrators @klassisch last edited by Homoran

                                            @klassisch sagte in Adapter "smartmeter":

                                            Vielleicht muß man da zusätzlich noch was einschalten bei diesem Blinkcode-Menue.

                                            @hotwire
                                            z.B. INFO - ON

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate
                                            FAQ Cloud / IOT
                                            HowTo: Node.js-Update
                                            HowTo: Backup/Restore
                                            Downloads
                                            BLOG

                                            581
                                            Online

                                            31.8k
                                            Users

                                            79.9k
                                            Topics

                                            1.3m
                                            Posts

                                            279
                                            3620
                                            2031105
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo