    This topic has been deleted. Only users with topic management privileges can see it.
    • F
      fL4sH 0 @foxriver76 last edited by

      @foxriver76 said in Alpha Testing: OCPP Wallbox Adapter:

      @fl4sh-0 cool die Meter values kann ich bei Gelegenheit einbauen gerne GitHub issue machen.

      Für das ändern des Limits, ich habe da bei mir nur bei inaktiven Ladevorgang getestet und da hat es funktioniert, wie hast du es getestet?

      Das Limit wird bei der ABB über Chargelimit nicht berücksichtigt. Ich habe alle Varianten durchgespielt.
      Inaktiven Ladevorgang -> Stecker nicht gesteckt
      Inaktiven Ladevorgang ->Stecker gesteckt
      Der eingestellte Wert im iobroker wird nicht übernommen.

      Anschließend habe ich noch mal den Wert in der App geändert um eine Veränderung im Log zu sehen und der letzte Wert der MeterValue ist der eingestellte ladestrom aus der App.

      v5.2.3
      
      0
      1
      Log-Größe: 835.3 KB
      
      ocpp.0
      Zeit
      debug
      Nachricht
      
      ocpp.0
      2022-01-18 22:04:56.747	warn	Client "/TACW1142021G1020" timed out
      
      ocpp.0
      2022-01-18 22:03:26.747	info	Received Status Notification from "/TACW1142021G1020": Available
      
      ocpp.0
      2022-01-18 22:03:26.747	debug	{"connectorId":1,"errorCode":"NoError","info":"null","status":"Available","vendorErrorCode":"0x00","commandOcpp":"StatusNotification"}
      
      ocpp.0
      2022-01-18 22:03:19.606	info	Received stop transaction from "/TACW1142021G1020"
      
      ocpp.0
      2022-01-18 22:03:19.606	debug	{"meterStop":113,"idTag":"1","timestamp":"2022-01-18T21:03:17.000Z","transactionId":1,"reason":"Remote","commandOcpp":"StopTransaction"}
      
      ocpp.0
      2022-01-18 22:03:19.106	info	Received Status Notification from "/TACW1142021G1020": Finishing
      
      ocpp.0
      2022-01-18 22:03:19.105	debug	{"connectorId":1,"errorCode":"NoError","info":"null","status":"Finishing","vendorErrorCode":"0x00","commandOcpp":"StatusNotification"}
      
      ocpp.0
      2022-01-18 22:03:17.744	debug	Received heartbeat from "/TACW1142021G1020"
      
      ocpp.0
      2022-01-18 22:03:17.744	debug	{"commandOcpp":"Heartbeat"}
      
      ocpp.0
      2022-01-18 22:03:17.245	info	Received Status Notification from "/TACW1142021G1020": SuspendedEV
      
      ocpp.0
      2022-01-18 22:03:17.245	debug	{"connectorId":1,"errorCode":"NoError","info":"null","status":"SuspendedEV","vendorErrorCode":"0x00","commandOcpp":"StatusNotification"}
      
      ocpp.0
      2022-01-18 22:03:14.759	debug	Sending RemoteStopTransaction for /TACW1142021G1020
      
      ocpp.0
      2022-01-18 22:02:55.293	info	Received MeterValues from "/TACW1142021G1020"
      
      ocpp.0
      2022-01-18 22:02:55.292	debug	{"connectorId":1,"transactionId":1,"meterValue":[{"timestamp":"2022-01-18T21:02:53.000Z","sampledValue":[{"value":"229.40","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L1-N","unit":"V"},{"value":"9.61","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L1","unit":"A"},{"value":"2175","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L1","unit":"W"},{"value":"229.90","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L2-N","unit":"V"},{"value":"9.56","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L2","unit":"A"},{"value":"2169","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L2","unit":"W"},{"value":"231.90","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L3-N","unit":"V"},{"value":"0.0","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L3","unit":"A"},{"value":"0","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L3","unit":"W"},{"value":"86","context":"Sample.Periodic","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh"},{"value":"10","context":"Sample.Periodic","format":"Raw","measurand":"Current.Offered","unit":"A"}]}],"commandOcpp":"MeterValues"}
      
      ocpp.0
      2022-01-18 22:02:23.367	info	Received MeterValues from "/TACW1142021G1020"
      
      ocpp.0
      2022-01-18 22:02:23.367	debug	{"connectorId":1,"transactionId":1,"meterValue":[{"timestamp":"2022-01-18T21:02:21.000Z","sampledValue":[{"value":"229.20","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L1-N","unit":"V"},{"value":"9.61","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L1","unit":"A"},{"value":"2174","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L1","unit":"W"},{"value":"229.60","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L2-N","unit":"V"},{"value":"9.57","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L2","unit":"A"},{"value":"2168","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L2","unit":"W"},{"value":"231.90","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L3-N","unit":"V"},{"value":"0.0","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L3","unit":"A"},{"value":"0","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L3","unit":"W"},{"value":"47","context":"Sample.Periodic","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh"},{"value":"10","context":"Sample.Periodic","format":"Raw","measurand":"Current.Offered","unit":"A"}]}],"commandOcpp":"MeterValues"}
      
      ocpp.0
      2022-01-18 22:01:51.432	info	Received MeterValues from "/TACW1142021G1020"
      
      ocpp.0
      2022-01-18 22:01:51.431	debug	{"connectorId":1,"transactionId":1,"meterValue":[{"timestamp":"2022-01-18T21:01:50.000Z","sampledValue":[{"value":"228.70","context":"Transaction.Begin","format":"Raw","measurand":"Voltage","phase":"L1-N","unit":"V"},{"value":"10.62","context":"Transaction.Begin","format":"Raw","measurand":"Current.Import","phase":"L1","unit":"A"},{"value":"2403","context":"Transaction.Begin","format":"Raw","measurand":"Power.Active.Import","phase":"L1","unit":"W"},{"value":"229.00","context":"Transaction.Begin","format":"Raw","measurand":"Voltage","phase":"L2-N","unit":"V"},{"value":"10.58","context":"Transaction.Begin","format":"Raw","measurand":"Current.Import","phase":"L2","unit":"A"},{"value":"2396","context":"Transaction.Begin","format":"Raw","measurand":"Power.Active.Import","phase":"L2","unit":"W"},{"value":"231.80","context":"Transaction.Begin","format":"Raw","measurand":"Voltage","phase":"L3-N","unit":"V"},{"value":"0.0","context":"Transaction.Begin","format":"Raw","measurand":"Current.Import","phase":"L3","unit":"A"},{"value":"0","context":"Transaction.Begin","format":"Raw","measurand":"Power.Active.Import","phase":"L3","unit":"W"},{"value":"0","context":"Transaction.Begin","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh"},{"value":"11","context":"Transaction.Begin","format":"Raw","measurand":"Current.Offered","unit":"A"}]}],"commandOcpp":"MeterValues"}
      
      ocpp.0
      2022-01-18 22:01:42.405	info	Received Start transaction from "/TACW1142021G1020"
      
      ocpp.0
      2022-01-18 22:01:42.404	debug	{"connectorId":1,"idTag":"1","meterStart":0,"timestamp":"2022-01-18T21:01:40.000Z","commandOcpp":"StartTransaction"}
      
      ocpp.0
      2022-01-18 22:01:41.903	info	Received Status Notification from "/TACW1142021G1020": Charging
      
      ocpp.0
      2022-01-18 22:01:41.902	debug	{"connectorId":1,"errorCode":"NoError","info":"null","status":"Charging","vendorErrorCode":"0x00","commandOcpp":"StatusNotification"}
      
      ocpp.0
      2022-01-18 22:01:41.403	info	Received Status Notification from "/TACW1142021G1020": SuspendedEV
      
      ocpp.0
      2022-01-18 22:01:41.402	debug	{"connectorId":1,"errorCode":"NoError","info":"null","status":"SuspendedEV","vendorErrorCode":"0x00","commandOcpp":"StatusNotification"}
      
      ocpp.0
      2022-01-18 22:01:40.892	debug	Sending RemoteStartTransaction for /TACW1142021G1020: {"connectorId":1,"idTag":"1","chargingProfile":{"chargingProfileId":1,"stackLevel":1,"chargingProfilePurpose":"TxProfile","chargingProfileKind":"Recurring","recurrencyKind":"Daily","chargingSchedule":{"duration":86400,"startSchedule":"2013-01-01T00:00Z","chargingRateUnit":"A","chargingSchedulePeriod":[{"startPeriod":0,"limit":8}]}}}
      
      foxriver76 1 Reply Last reply Reply Quote 0
      • foxriver76
        foxriver76 Developer @fL4sH 0 last edited by

        @fl4sh-0 habe die meterValues eingebaut mit 0.3.0 den alten meterValue State bitte manuell löschen.

        Dass die Ladeleistung bei den ABB Boxen nicht angezogen wird kann ich nicht ganz nachvollziehen, weiß aktuell leider nicht woran es liegt

        F 2 Replies Last reply Reply Quote 0
        • F
          fL4sH 0 @foxriver76 last edited by

          @foxriver76

          @foxriver76 said in Alpha Testing: OCPP Wallbox Adapter:

          @fl4sh-0 habe die meterValues eingebaut mit 0.3.0 den alten meterValue State bitte manuell löschen.

          Dass die Ladeleistung bei den ABB Boxen nicht angezogen wird kann ich nicht ganz nachvollziehen, weiß aktuell leider nicht woran es liegt

          Ach mega cool! Das ging schnell und funktioniert. Vielen Dank.

          Screenshot_20220118-230644_Chrome.jpg

          1 Reply Last reply Reply Quote 0
          • F
            fL4sH 0 @foxriver76 last edited by

            @foxriver76 said in Alpha Testing: OCPP Wallbox Adapter:

            @fl4sh-0 habe die meterValues eingebaut mit 0.3.0 den alten meterValue State bitte manuell löschen.

            Dass die Ladeleistung bei den ABB Boxen nicht angezogen wird kann ich nicht ganz nachvollziehen, weiß aktuell leider nicht woran es liegt

            Ich habe noch mal ein bisschen mit dem Ladelimit getestet. Das stand im Log:

            
            ocpp.0
            2022-01-19 07:28:25.519	debug	Sending RemoteStartTransaction for /TACW1142021G1020: {"connectorId":1,"idTag":"1","chargingProfile":{"chargingProfileId":1,"stackLevel":1,"chargingProfilePurpose":"TxProfile","chargingProfileKind":"Recurring","recurrencyKind":"Daily","chargingSchedule":{"duration":86400,"startSchedule":"2013-01-01T00:00Z","chargingRateUnit":"A","chargingSchedulePeriod":[{"startPeriod":0,"limit":8}]}}}
            
            ocpp.0
            2022-01-19 07:27:46.152	debug	Sending SetChargingProfile for /TACW1142021G1020
            

            Gesendet wird das SetChargingProfile auch und wenn anschließend die Transaktion gestartet wird, sendet er auch einige Daten. Was ich mich nur frage warum startSchedule":"2013-01-01T00:00Z diesen Zeitstempel hat?

            Hier sind noch Auszüge aus der Ocpp Dokumentation der ABB.
            2c86c564-8739-4b92-a284-69eb7269de77-image.png
            f1225765-aecd-45cd-8203-81612244ce89-image.png
            Vielleicht kannst du damit ja was anfangen und es hilft dir weiter.

            foxriver76 1 Reply Last reply Reply Quote 0
            • foxriver76
              foxriver76 Developer @fL4sH 0 last edited by

              @fl4sh-0

              Was ich mich nur frage warum startSchedule":"2013-01-01T00:00Z diesen Zeitstempel hat?

              443B6BC4-106C-46E8-BBB7-1F6FD540DCF7.png

              Ist der example Zeitstempel aus der OCPP Doku um das zu bewirken.

              Was ich noch sehe bei dir Max Stack Level 0 wir setzen 1 evtl ist es das noch. Nervig nach wie vor dass ich die Config nicht zurück bekomme sonst könnte ich sowas im Adapter dynamisch behandeln.

              F 1 Reply Last reply Reply Quote 0
              • F
                fL4sH 0 @foxriver76 last edited by

                @foxriver76 said in Alpha Testing: OCPP Wallbox Adapter:

                @fl4sh-0
                Was ich noch sehe bei dir Max Stack Level 0 wir setzen 1 evtl ist es das noch. Nervig nach wie vor dass ich die Config nicht zurück bekomme sonst könnte ich sowas im Adapter dynamisch behandeln.

                Dann hätte man ja eventuell schon was gefunden wo man ansetzten kann.
                Was meinst du denn damit, das du die Config nicht zurück bekommst, wenn ich fragen darf?
                Könnte man solche Sachen nicht über eine Variablen aus dem OCPP Adapter aussteuern, ähnlich wie beim Port ?

                foxriver76 1 Reply Last reply Reply Quote 0
                • foxriver76
                  foxriver76 Developer @fL4sH 0 last edited by

                  @fl4sh-0 Das mit dem stackLevel können wir später probieren.

                  Konfigurierbar ja wäre möglich, ist aber ja schon sehr technisch und für den Anwender jetzt nicht so spannend. Eigentlich müsste die WB auf einen GetConfiguration Request antworten. In der Antwort würden dann auch Informationen wie das maxStackLevel stehen.

                  Leider antwortet bislang keine WB darauf obwohl sie es sollte, auf meiner Seite sehe ich leider aktuell keinen Fehler.

                  F 1 Reply Last reply Reply Quote 0
                  • F
                    fL4sH 0 @foxriver76 last edited by

                    @foxriver76 said in Alpha Testing: OCPP Wallbox Adapter:

                    @fl4sh-0 Das mit dem stackLevel können wir später probieren.

                    Konfigurierbar ja wäre möglich, ist aber ja schon sehr technisch und für den Anwender jetzt nicht so spannend. Eigentlich müsste die WB auf einen GetConfiguration Request antworten. In der Antwort würden dann auch Informationen wie das maxStackLevel stehen.

                    Leider antwortet bislang keine WB darauf obwohl sie es sollte, auf meiner Seite sehe ich leider aktuell keinen Fehler.

                    Das sind die GetConfiguration Daten aus der ABB Dokumentation.

                    3a330eb3-ba82-41bc-a67f-403a71dceed3-image.png
                    ca085595-d120-4a54-8945-be99b03df3b2-image.png

                    foxriver76 1 Reply Last reply Reply Quote 0
                    • foxriver76
                      foxriver76 Developer @fL4sH 0 last edited by

                      @fl4sh-0 Ich habe bereits probiert einzelne Keys die sicher vorhanden sein müssten zu requesten, als auch die gesamte Config. Habe ben nochmal nachgeschaut.. keine Ahnung woran es liegt.

                      Ich habe auf GitHub das stackLevel auf 0 geändert, bitte mal testen.

                      F 2 Replies Last reply Reply Quote 0
                      • F
                        fL4sH 0 @foxriver76 last edited by fL4sH 0

                        @foxriver76 said in Alpha Testing: OCPP Wallbox Adapter:

                        @fl4sh-0 Ich habe bereits probiert einzelne Keys die sicher vorhanden sein müssten zu requesten, als auch die gesamte Config. Habe ben nochmal nachgeschaut.. keine Ahnung woran es liegt.

                        Ich habe auf GitHub das stackLevel auf 0 geändert, bitte mal testen.

                        Anbei die Logdatei mit dem stacklevel 0 leider ohne Erfolg. Er sendet zwar SetChargingProfile aber kann es anscheind nicht verarbeiten.

                        Über die APP kann man das Limit zwischen 6A -16A stufenlos einstellen auch während eines Ladevorgangs. Aber für PV-Überschussladung ist das über die App nicht realisierbar und auch nur über Bluetooth steuerbar. Gibt es vllt noch eine andere Möglichkeit woran es liegen kann das der das Limit nicht setzt?

                        ocpp.0 2022-01-19 10:39:38.888	debug	{"connectorId":1,"transactionId":1,"meterValue":[{"timestamp":"2022-01-19T09:39:38.000Z","sampledValue":[{"value":"229.10","context":"Transaction.Begin","format":"Raw","measurand":"Voltage","phase":"L1-N","unit":"V"},{"value":"5.77","context":"Transaction.Begin","format":"Raw","measurand":"Current.Import","phase":"L1","unit":"A"},{"value":"16","context":"Transaction.Begin","format":"Raw","measurand":"Power.Active.Import","phase":"L1","unit":"W"},{"value":"229.00","context":"Transaction.Begin","format":"Raw","measurand":"Voltage","phase":"L2-N","unit":"V"},{"value":"5.76","context":"Transaction.Begin","format":"Raw","measurand":"Current.Import","phase":"L2","unit":"A"},{"value":"5","context":"Transaction.Begin","format":"Raw","measurand":"Power.Active.Import","phase":"L2","unit":"W"},{"value":"230.90","context":"Transaction.Begin","format":"Raw","measurand":"Voltage","phase":"L3-N","unit":"V"},{"value":"0.0","context":"Transaction.Begin","format":"Raw","measurand":"Current.Import","phase":"L3","unit":"A"},{"value":"0","context":"Transaction.Begin","format":"Raw","measurand":"Power.Active.Import","phase":"L3","unit":"W"},{"value":"0","context":"Transaction.Begin","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh"},{"value":"6","context":"Transaction.Begin","format":"Raw","measurand":"Current.Offered","unit":"A"}]}],"commandOcpp":"MeterValues"}
                        ocpp.0 2022-01-19 10:39:30.629	info	Received Start transaction from "/TACW1142021G1020"
                        ocpp.0 2022-01-19 10:39:30.628	debug	{"connectorId":1,"idTag":"1","meterStart":0,"timestamp":"2022-01-19T09:39:29.000Z","commandOcpp":"StartTransaction"}
                        ocpp.0 2022-01-19 10:39:29.936	info	Received Status Notification from "/TACW1142021G1020": Charging
                        ocpp.0 2022-01-19 10:39:29.936	debug	{"connectorId":1,"errorCode":"NoError","info":"null","status":"Charging","vendorErrorCode":"0x00","commandOcpp":"StatusNotification"}
                        ocpp.0 2022-01-19 10:39:28.982	info	Received Status Notification from "/TACW1142021G1020": SuspendedEV
                        ocpp.0 2022-01-19 10:39:28.981	debug	{"connectorId":1,"errorCode":"NoError","info":"null","status":"SuspendedEV","vendorErrorCode":"0x00","commandOcpp":"StatusNotification"}
                        ocpp.0 2022-01-19 10:39:28.465	debug	Sending RemoteStartTransaction for /TACW1142021G1020: {"connectorId":1,"idTag":"1","chargingProfile":{"chargingProfileId":1,"stackLevel":0,"chargingProfilePurpose":"TxProfile","chargingProfileKind":"Recurring","recurrencyKind":"Daily","chargingSchedule":{"duration":86400,"startSchedule":"2013-01-01T00:00Z","chargingRateUnit":"A","chargingSchedulePeriod":[{"startPeriod":0,"limit":10}]}}}
                        ocpp.0 2022-01-19 10:39:13.348	debug	Received heartbeat from "/TACW1142021G1020"
                        ocpp.0 2022-01-19 10:39:13.347	debug	{"commandOcpp":"Heartbeat"}
                        ocpp.0 2022-01-19 10:38:58.104	debug	Sending SetChargingProfile for /TACW1142021G1020
                        ocpp.0 2022-01-19 10:38:18.006	info	Sending GetConfiguration to "/TACW1142021G1020"
                        
                        
                        ocpp.02022-01-19 11:57:33.366	debug	Sending RemoteStartTransaction for /TACW1142021G1020: {"connectorId":1,"idTag":"1","chargingProfile":{"chargingProfileId":1,"stackLevel":0,"chargingProfilePurpose":"TxProfile","chargingProfileKind":"Recurring","recurrencyKind":"Daily","chargingSchedule":{"duration":86400,"startSchedule":"2013-01-01T00:00Z","chargingRateUnit":"A","chargingSchedulePeriod":[{"startPeriod":0,"limit":9}]}}}
                        ocpp.02022-01-19 12:16:06.331	debug	Sending SetChargingProfile for /TACW1142021G1020
                        
                        1 Reply Last reply Reply Quote 0
                        • F
                          fL4sH 0 @foxriver76 last edited by fL4sH 0

                          @foxriver76 Moin, könntest du einmal beschreiben wie dein Vorgehen beim einstellen des Ladelimits ist. Ich würde das dann gerne nochmal genau so nachspielen.

                          Gibt es die Möglichkeit das Ladelimit gesondert zu pushen ?

                          Könnte man den startSchedule":"2013-01-01T00:00Z im SetChargingProfil auf das aktuelle Datum setzen ? Nicht das die Wallbox damit nicht klar kommt weil der Wert soweit in der Vergangenheit liegt. Hatte schon ein paar andere SetChargingProfile gesehen wo ein aktuelles Datum hinterlegt war.

                          Gruß Tobias

                          foxriver76 1 Reply Last reply Reply Quote 0
                          • foxriver76
                            foxriver76 Developer @fL4sH 0 last edited by foxriver76

                            @fl4sh-0

                            Hatte schon ein paar andere SetChargingProfile gesehen wo ein aktuelles Datum hinterlegt war.

                            Wo?

                            Ja bin das WE allerdings unterwegs. Du kannst dir Daten auch lokal bei dir ändern wenn du dir das zutraust um mal rum zu spielen, die Stellen sollten identifizierbar sein. /opt/iobroker/node_modules/iobroker.ocpp/build/main.js oder Windows analog.

                            https://github.com/foxriver76/ioBroker.ocpp/blob/86dbc2f6f88ee6e6aead8d686356671a10b4ef4c/build/main.js#L341

                            Und

                            https://github.com/foxriver76/ioBroker.ocpp/blob/86dbc2f6f88ee6e6aead8d686356671a10b4ef4c/build/main.js#L393

                            F 2 Replies Last reply Reply Quote 0
                            • F
                              fL4sH 0 @foxriver76 last edited by fL4sH 0

                              @foxriver76 said in Alpha Testing: OCPP Wallbox Adapter:

                              @fl4sh-0

                              Hatte schon ein paar andere SetChargingProfile gesehen wo ein aktuelles Datum hinterlegt war.

                              Wo?

                              Ja bin das WE allerdings unterwegs. Du kannst dir Daten auch lokal bei dir ändern wenn du dir das zutraust um mal rum zu spielen, die Stellen sollten identifizierbar sein. /opt/iobroker/node_modules/iobroker.ocpp/build/main.js oder Windows analog.

                              https://github.com/foxriver76/ioBroker.ocpp/blob/86dbc2f6f88ee6e6aead8d686356671a10b4ef4c/build/main.js#L341

                              Und

                              https://github.com/foxriver76/ioBroker.ocpp/blob/86dbc2f6f88ee6e6aead8d686356671a10b4ef4c/build/main.js#L393

                              Hatte das mal auf anderen Seiten gesehen: Hier die Beispiele.

                              "SetChargingProfile",{"connectorId":0,"csChargingProfiles":{"chargingProfileId":10,"stackLevel":0,"chargingProfilePurpose":"TxDefaultProfile","chargingProfileKind":"Absolute","recurrencyKind":"Daily","validFrom":"2019-10-22T08:25:00.000Z","validTo":"2019-10-22T08:36:00.000Z","chargingSchedule":{"startSchedule":"2019-10-22T08:26:00.000Z","chargingRateUnit":"A","chargingSchedulePeriod":[{"startPeriod":0,"limit":1,"numberPhases":3}]}}}]
                              
                              SetChargingProfile exchange:
                              "SetChargingProfile",{"connectorId":1,"csChargingProfiles":{"chargingProfileId":100,"stackLevel":0,"chargingProfilePurpose":"TxDefaultProfile","chargingProfileKind":"Recurring","recurrencyKind":"Daily","validFrom":"2018-05-12T00:00:00.000Z","validTo":"2018-05-19T00:00:00.000Z","chargingSchedule":{"duration":86400,"chargingRateUnit":"A","chargingSchedulePeriod":[{"startPeriod":0,"limit":25.5,"numberPhases":1},{"startPeriod":28800,"limit":15.5,"numberPhases":1},{"startPeriod":72000,"limit":25,"numberPhases":1}]}}}]
                              
                              GetCompositeSchedule exchange:
                              "GetCompositeSchedule",{"connectorId":1,"duration":86400,"chargingRateUnit":"A"}]
                              
                              Sending RemoteStartTransaction for /ABB-Terra-AC: {"connectorId":1,"idTag":"1","chargingProfile":{"chargingProfileId":1,"stackLevel":0,"chargingProfilePurpose":"TxProfile","chargingProfileKind":"Recurring","recurrencyKind":"Daily","chargingSchedule":{"duration":86400,"startSchedule":"2013-01-01T00:00Z","chargingRateUnit":"A","chargingSchedulePeriod":[{"startPeriod":0,"limit":12}]}}}
                              

                              Ich habe mit der main.js mal ein bisschen rumgespielt und die Werte ein bisschen geändert aber leider ohne Erfolg.
                              Die Wallbox will das chargelimit immer noch nicht übernehmen......

                              Ich habe mal eine Anfrage direkt zu ABB geschickt und schaue mal ob die sich dazu äußern.

                              foxriver76 1 Reply Last reply Reply Quote 0
                              • foxriver76
                                foxriver76 Developer @fL4sH 0 last edited by

                                @fl4sh-0 Nach verändern der main.js auch immer Adapter neugestartet?

                                F 1 Reply Last reply Reply Quote 0
                                • F
                                  fL4sH 0 @foxriver76 last edited by

                                  @foxriver76 said in Alpha Testing: OCPP Wallbox Adapter:

                                  @fl4sh-0 Nach verändern der main.js auch immer Adapter neugestartet?

                                  Einen Neustart habe ich immer gemacht weil er sonst die Daten nicht übernommen hatte 😉

                                  foxriver76 1 Reply Last reply Reply Quote 0
                                  • foxriver76
                                    foxriver76 Developer @fL4sH 0 last edited by

                                    @fl4sh-0 Top, also richtig gemacht, schade dass es erfolglos war.

                                    1 Reply Last reply Reply Quote 0
                                    • F
                                      fL4sH 0 @foxriver76 last edited by

                                      @foxriver76 said in Alpha Testing: OCPP Wallbox Adapter:

                                      @fl4sh-0

                                      Hatte schon ein paar andere SetChargingProfile gesehen wo ein aktuelles Datum hinterlegt war.

                                      Wo?

                                      Ja bin das WE allerdings unterwegs. Du kannst dir Daten auch lokal bei dir ändern wenn du dir das zutraust um mal rum zu spielen, die Stellen sollten identifizierbar sein. /opt/iobroker/node_modules/iobroker.ocpp/build/main.js oder Windows analog.

                                      https://github.com/foxriver76/ioBroker.ocpp/blob/86dbc2f6f88ee6e6aead8d686356671a10b4ef4c/build/main.js#L341

                                      Und

                                      https://github.com/foxriver76/ioBroker.ocpp/blob/86dbc2f6f88ee6e6aead8d686356671a10b4ef4c/build/main.js#L393

                                      Worin besteht eigentlich der unterschied zwischen diesen beiden Blöcken ?
                                      Beim oberen Block ist: limit: limitState.val und beim unteren limit: state.val

                                      Wenn ich das richtig lese, sendet der untere Block doch "SetChargingProfile" oder ?

                                      foxriver76 1 Reply Last reply Reply Quote 0
                                      • foxriver76
                                        foxriver76 Developer @fL4sH 0 last edited by

                                        @fl4sh-0 Ist ein mal das Kommando um um die einen Ladevorgang zu starten (hier wird dann eben auch das aktuell in iob eingestellte limit mit gegeben) und das andere ist allgemein das setzen des limits, also auch während dem aktiven Ladevorgang ändern beispielsweise.

                                        F 1 Reply Last reply Reply Quote 0
                                        • F
                                          fL4sH 0 @foxriver76 last edited by

                                          @foxriver76 said in Alpha Testing: OCPP Wallbox Adapter:

                                          @fl4sh-0 Ist ein mal das Kommando um um die einen Ladevorgang zu starten (hier wird dann eben auch das aktuell in iob eingestellte limit mit gegeben) und das andere ist allgemein das setzen des limits, also auch während dem aktiven Ladevorgang ändern beispielsweise.

                                          Moinsen,

                                          es gibt neue Erkenntnisse bzgl. des Ladelimit.

                                          24a0728f-1489-4463-a9e9-202177effd3d-image.png
                                          Der Wert "Current_Offered" ist der maximal zulässig Wert der Wallbox. Dieser Wert kann über die APP bis 16A eingestellt werden. Das Ladelimit kann nur unterhalb dieses Wertes geändert werden aber auch während eines Ladevorgangs.

                                          Ich hatte anfangs versucht den Wert der Ladelimits über den Wert "Current_Offered" zusetzen. Das hatte dann aber keine Auswirkung in kombination mit Stacklevel max=1.

                                          Das heißt das die Änderung mit dem Stacklevel max = 0 funktioniert bei der ABB Terra AC.

                                          So kann das Ladelimit mit PV-Überschuss variabel gesteuert werden und erfüllt somit die Anforderung die ich hatte.

                                          Vielen Dank!!!

                                          foxriver76 1 Reply Last reply Reply Quote 0
                                          • foxriver76
                                            foxriver76 Developer @fL4sH 0 last edited by foxriver76

                                            @fl4sh-0 Super, sprich mit der aktuellen Version kannst du das chargeLimit zwischen Untergrenze/Obergrenze korrekt setzen, ist bei mir dasselbe, geht glaube nur zwischen 6 und 16 A. 👍

                                            Dann veröffentliche ich die Version mal auf npm

                                            F 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            485
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            adapter ocpp wallbox
                                            48
                                            440
                                            78158
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo