    This topic has been deleted. Only users with topic management privileges can see it.
    • da_Woody
      da_Woody @dslraser last edited by

      @dslraser weils mir ins auge gehüpft ist. hab dir die fensterisons im blau angepasst...
      window_closed.png window_tilted.png window_opened.png

      1 Reply Last reply Reply Quote 1
      • O
        Opa75+ @dslraser last edited by

        @dslraser GELÖST😀 😀

        dslraser 1 Reply Last reply Reply Quote 0
        • dslraser
          dslraser Forum Testing Most Active @Opa75+ last edited by dslraser

          @opa75 sagte in iQontrol Vis Support Thread:

          @dslraser GELÖST😀 😀

          hier nochmal mit Bildern (weil im Chat keine Bilder gehen)

          ganz rechts Optionen

          4C0807CA-E26C-4F30-8315-2A0CBA14FD94.jpeg

          ganz unten Sichern/Wiederherstellen

          0188DC87-ADF5-452C-B5AC-F6F6B8E6BD84.jpeg

          EDIT: das hier ist der View Export

          so exportiert

          Bildschirmfoto 2022-04-01 um 20.03.49.png

          2022-04-01_iqontrol_0_selected_views.json

          hier als Zip zum downloaden

          2022-04-01_iqontrol_0_selected_views.json.zip

          Du kannst das damit wiederherstellen

          Bildschirmfoto 2022-04-01 um 20.04.03.png

          Das ist diese Ansicht(View)

          9D195264-56EE-4ED8-BEB1-265564F851CD.png

          1 Reply Last reply Reply Quote 2
          • D
            DasMoritz @s.bormann last edited by DasMoritz

            Hallo,

            ich habe eine Frage:
            Wie bekomme ich in iQontrol die Einheiten "aktiviert"?

            Ich habe mir folgende Ansicht gebaut, bekomme jedoch außer bei der Erzeugungsleistung (ganz obere Kachel) keine Einheiten (Watt) angezeigt.

            16450704-552a-4c87-8369-a5fa82fdd334-image.png

            Hat da jemand eine Idee?
            Und: Wie bekomme ich den ganzen Kram irgendwie "heller"?
            Das sieht alles total dunkel aus.

            Danke,
            Moritz

            dslraser 1 Reply Last reply Reply Quote 0
            • dslraser
              dslraser Forum Testing Most Active @DasMoritz last edited by dslraser

              @dasmoritz

              https://github.com/sbormann/ioBroker.iqontrol#modifying-datapoint-configuration

              Bildschirmfoto 2022-04-05 um 11.10.36.png

              D 1 Reply Last reply Reply Quote 0
              • D
                DasMoritz @dslraser last edited by

                @dslraser Perfekt Danke! So simpel 🙂

                Frage: Kann ich in IQontrol auch Werte berechnen?
                Ich habe eine Darstellung in "Wh", sinnvoller wäre aber in "kWh", sprich den Wert / 1000 teilen und dann als Einheit kWh vergeben.

                Geht das irgendwie in dem Datenpunkt als Darstellung oder sollte ich dafür einen neuen Datenpunkt aufbauen, der aus dem bestehenden Datenpunkt den Wert übernimmt und /1000 rechnet?

                Danke,
                Moritz

                dslraser 1 Reply Last reply Reply Quote 0
                • dslraser
                  dslraser Forum Testing Most Active @DasMoritz last edited by

                  @dasmoritz sagte in iQontrol Vis Support Thread:

                  @dslraser Perfekt Danke! So simpel 🙂

                  Frage: Kann ich in IQontrol auch Werte berechnen?
                  Ich habe eine Darstellung in "Wh", sinnvoller wäre aber in "kWh", sprich den Wert / 1000 teilen und dann als Einheit kWh vergeben.

                  Geht das irgendwie in dem Datenpunkt als Darstellung oder sollte ich dafür einen neuen Datenpunkt aufbauen, der aus dem bestehenden Datenpunkt den Wert übernimmt und /1000 rechnet?

                  Danke,
                  Moritz

                  Das ginge mit einem alias sehr einfach. Beispiel müsste ich aber erst raussuchen.

                  S 1 Reply Last reply Reply Quote 0
                  • O
                    Opa75+ @dslraser last edited by

                    @dslraser Wo kann man die Anzeige "Ein" umschreiben auf "an", damit das Icon "Schalter ein" angezeigt wird. ???
                    Wie kann man, wie bei "Schalter aus" den grünen Hacken, beim "Schalter ein" ein Rufzeichen mit anzeigen.

                    Stecker1.jpg
                    Beim Icon replacement ist der Icon Schalter (grün) eingetragen und die Bezeichnung (Caption) auf an.

                    dslraser 1 Reply Last reply Reply Quote 0
                    • dslraser
                      dslraser Forum Testing Most Active @Opa75+ last edited by dslraser

                      @opa75 sagte in iQontrol Vis Support Thread:

                      @dslraser Wo kann man die Anzeige "Ein" umschreiben auf "an", damit das Icon "Schalter ein" angezeigt wird. ???
                      Wie kann man, wie bei "Schalter aus" den grünen Hacken, beim "Schalter ein" ein Rufzeichen mit anzeigen.

                      Stecker1.jpg
                      Beim Icon replacement ist der Icon Schalter (grün) eingetragen und die Bezeichnung (Caption) auf an.

                      Was steht denn im Datenpunkt? (Ein oder ein)

                      O 1 Reply Last reply Reply Quote 0
                      • O
                        Opa75+ @dslraser last edited by

                        @dslraser Das ist "tue"!

                        dslraser 1 Reply Last reply Reply Quote 0
                        • dslraser
                          dslraser Forum Testing Most Active @Opa75+ last edited by dslraser

                          @opa75 sagte in iQontrol Vis Support Thread:

                          @dslraser Das ist "tue"!

                          Zeig mal bitte den RAW eines solchen Datenpunktes.

                          EDIT: meine alias (Beispiel Steckdosen) sind so konfiguriert (siehe Zeile 14 und 15)

                          {
                            "type": "state",
                            "common": {
                              "def": false,
                              "type": "boolean",
                              "read": true,
                              "write": true,
                              "role": "switch",
                              "name": "Befeuchter",
                              "alias": {
                                "id": "hm-rpc.0.00021709A0EFAE.3.STATE"
                              },
                              "states": {
                                "false": "aus",
                                "true": "an"
                              },
                              "smartName": false
                            },
                            "native": {},
                            "_id": "alias.0.Steckdosen.Befeuchter",
                            "acl": {
                              "object": 1636,
                              "state": 1636,
                              "owner": "system.user.admin",
                              "ownerGroup": "system.group.administrator"
                            },
                            "from": "system.adapter.admin.0",
                            "user": "system.user.admin",
                            "ts": 1644140339296
                          }
                          

                          und in iQontrol ist es dann so konfiguriert

                          Bildschirmfoto 2022-04-06 um 19.49.32.png

                          Bildschirmfoto 2022-04-06 um 19.50.37.png

                          Bildschirmfoto 2022-04-06 um 19.50.55.png

                          sieht dann so bei mir aus

                          Bildschirmfoto 2022-04-06 um 19.52.07.png

                          Das mußt Du dann eine Deine Wünsche anpassen...

                          Beispiel 2 zum Verständnis (alias meiner Bewegungsmelder)

                          {
                            "type": "state",
                            "common": {
                              "def": false,
                              "type": "boolean",
                              "read": true,
                              "write": false,
                              "role": "sensor.motion",
                              "name": "Gäste WC Tür",
                              "alias": {
                                "id": "hm-rpc.0.0014D8A98A0FE2.3.MOTION"
                              },
                              "desc": "per Script erstellt",
                              "states": {
                                "false": "inaktiv",
                                "true": "aktiv"
                              }
                            },
                            "native": {},
                            "from": "system.adapter.javascript.0",
                            "user": "system.user.admin",
                            "ts": 1600721675844,
                            "_id": "alias.0.Bewegungsmelder.Bewegungsmelder_Gaeste_WC_Tuer",
                            "acl": {
                              "object": 1636,
                              "state": 1636,
                              "owner": "system.user.admin",
                              "ownerGroup": "system.group.administrator"
                            }
                          }
                          

                          Bildschirmfoto 2022-04-06 um 19.54.48.png

                          Bildschirmfoto 2022-04-06 um 19.54.57.png

                          Bildschirmfoto 2022-04-06 um 19.55.22.png

                          O 1 Reply Last reply Reply Quote 0
                          • O
                            Opa75+ last edited by

                            Anbei das RAW

                            {
                              "common": {
                                "type": "boolean",
                                "read": true,
                                "write": true,
                                "name": "OG Stecker im BFritz",
                                "role": "switch"
                              },
                              "native": {
                                "valueTrue": "ON",
                                "valueFalse": "OFF",
                                "actionTrue": "turnOn",
                                "actionFalse": "turnOff",
                                "supportedActions": [
                                  "turnOn",
                                  "turnOff"
                                ]
                              },
                              "type": "state",
                              "_id": "alexa2.0.Smart-Home-Devices.daaa607f-87b5-45dd-8dfa-4eb53de63df8.powerState",
                              "acl": {
                                "object": 1636,
                                "state": 1636,
                                "owner": "system.user.admin",
                                "ownerGroup": "system.group.administrator"
                              },
                              "from": "system.adapter.admin.0",
                              "user": "system.user.admin",
                              "ts": 1649233720162
                            }
                            
                            dslraser 1 Reply Last reply Reply Quote 0
                            • dslraser
                              dslraser Forum Testing Most Active @Opa75+ last edited by

                              @opa75
                              das ist ein Datenpunkt vom alexa2 Adapter...? (warum nimmst Du den ?)

                              1 Reply Last reply Reply Quote 0
                              • O
                                Opa75+ @dslraser last edited by

                                @dslraser Die Eintragungen wie bei Bild 2 sind bei mir gleich. Werde bei den Alexa RAW die Daten ändern auf aus an.

                                dslraser 1 Reply Last reply Reply Quote 0
                                • dslraser
                                  dslraser Forum Testing Most Active @Opa75+ last edited by dslraser

                                  @opa75 sagte in iQontrol Vis Support Thread:

                                  @dslraser Werde bei den Alexa RAW die Daten ändern auf aus an.

                                  nein, dieser Datenpunkt wird vom alexa2 Adapter "verwaltet". Nimm einen originalen Datenpunkt oder besser einen alias. Was ist das denn für ein Gerät ?

                                  O 1 Reply Last reply Reply Quote 0
                                  • O
                                    Opa75+ @dslraser last edited by

                                    @dslraser Ok dann weiß ich Bescheid.
                                    Muss die Stecker entsprechend ändern. Anbei RAW Fenster

                                    {
                                      "from": "system.adapter.admin.0",
                                      "user": "system.user.admin",
                                      "ts": 1646558778343,
                                      "common": {
                                        "name": "EG_KiZ_Fenster",
                                        "role": "sensor.window",
                                        "type": "boolean",
                                        "read": true,
                                        "write": false,
                                        "alias": {
                                          "id": "hmip.0.devices.3014F711A00000DBE99ACCDA.channels.1.windowOpen"
                                        },
                                        "states": {
                                          "true": "geöffnet",
                                          "false": "geschlossen"
                                        }
                                      },
                                      "native": {},
                                      "acl": {
                                        "object": 1636,
                                        "owner": "system.user.admin",
                                        "ownerGroup": "system.group.administrator",
                                        "state": 1636
                                      },
                                      "_id": "alias.0.Fenster.EG_KiZ_Fenster",
                                      "type": "state"
                                    }
                                    

                                    Bei den Steckern habe ich das noch nicht gemacht-

                                    1 Reply Last reply Reply Quote 0
                                    • G
                                      Geesthachter @s.bormann last edited by

                                      Ich habe mal eine Frage an die Experten hier,
                                      ich habe im Forum für VIS, tolle Visualisierungsumsetzungen für Spotify gefunden. siehe hier: https://forum.iobroker.net/topic/19859/suche-spotify-view/21
                                      gibt es ähnliche Visualisierungen auch für iQontrol?

                                      1 Reply Last reply Reply Quote 0
                                      • S
                                        stelu22 @dslraser last edited by

                                        @dslraser HAllo dslraser, ich wäre auch sehr an einer Lösung zur Konvertierung interessiert. In den objekt eigenschaften kann ich ja tatsächlich kW angeben, iq spuckt aber immer noch die mW meiner Wallbox aus sehr unhandlich!

                                        S 1 Reply Last reply Reply Quote 0
                                        • S
                                          stelu22 @stelu22 last edited by

                                          @stelu22 Vielleicht hat jemand noch eine Idee wie ich von mW auf kW umrechnen kann ?? In vis z. B. ist das ja unproblematisch. Iqontrol hat ja so unendlich viele Möglichkeiten das ich das Gefühl habe da auf dem Schlauch zu stehen.

                                          s.bormann 1 Reply Last reply Reply Quote 0
                                          • s.bormann
                                            s.bormann Most Active @stelu22 last edited by

                                            @stelu22 sagte in iQontrol Vis Support Thread:

                                            @stelu22 Vielleicht hat jemand noch eine Idee wie ich von mW auf kW umrechnen kann ?? In vis z. B. ist das ja unproblematisch. Iqontrol hat ja so unendlich viele Möglichkeiten das ich das Gefühl habe da auf dem Schlauch zu stehen.

                                            Hallo, umrechnen kann iQontrol nicht. Aber das lässt sich relativ einfach über ein Alias erreichen. Dabei kann man Umrechnungs-Funktionen (für Lesen und Schreiben) angeben. Du müsstest als Lese-Funktion val/1000000 nehmen. Als "unit" nimmst Du dann "kW". Dann fügst Du in iQontrol den Alias-Datenpunkt, statt dem original Datenpunkt ein. Aliase kannst Du händisch, mit dem Devices-Adapter oder mit dem Alias-Manager erstellen.
                                            VG

                                            O S 2 Replies Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            796
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            android app vis how-to ios app iqontrol mobile ui vis
                                            120
                                            1485
                                            497359
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo