      PLCHome 0 Developer @tombox last edited by

      @tombox In den Confis steht, dass Passwörter verschlüsselt sein sollen, es gibt auch einen Beispielcode für den iobroker

      T 1 Reply Last reply Reply Quote 0
      • T
        tombox @PLCHome 0 last edited by

        @plchome-0 Wird native von ioBroker verschlüsselt
        https://github.com/TA2k/ioBroker.intex/blob/050e7132fd077ccfacba0f3488be9e76f733928e/io-package.json#L93

        PLCHome 0 1 Reply Last reply Reply Quote 0
        • PLCHome 0
          PLCHome 0 Developer @tombox last edited by

          @tombox aha den kannte ich nicht, ich musste damals noch den Code einfügen, damit der Adapter Stabile werden konnte

          T 1 Reply Last reply Reply Quote 0
          • T
            tombox @PLCHome 0 last edited by

            @plchome-0 Adapter ist auch schon im stabilen branch

            1 Reply Last reply Reply Quote 0
            • PLCHome 0
              PLCHome 0 Developer last edited by

              @tombox OK. Was hältst du von prettier im zusammenhang mit lint?

              1 Reply Last reply Reply Quote 0
              • PLCHome 0
                PLCHome 0 Developer @grex1975 last edited by PLCHome 0

                @grex1975 @tombox
                Hallo zusammen,

                ich habe jetzt das Umschalten von Celsius und Fahrenheit eingebaut.
                Die control sollten jetzt definiert schalten, das funktioniert nach folgendem Schema:

                • Der ist Zustand, wird mit dem soll Zustand verglichen.
                • Ist er ungleich, wird geschaltet.
                • Der Zustand wird gemerkt und beim nächsten Update abgeglichen.
                • Ist der Zustand nun unterschiedlich, wird noch mal geschaltet.
                • Das wird 5-mal versucht, danach kommt die Warnung, dass nicht gesetzt werden kann.
                G 1 Reply Last reply Reply Quote 0
                • G
                  grex1975 @PLCHome 0 last edited by

                  @plchome-0
                  Hallo

                  umschalten C/F von iobroker aus funktioniert einwandfrei bei mir.
                  jetzt brauche ich noch das Schalten der Heizfunktion dann könnte ich die Heizung in Abhängigkeit der PV Anlage programmieren 🙂

                  G PLCHome 0 3 Replies Last reply Reply Quote 0
                  • G
                    grex1975 @grex1975 last edited by

                    Wie läuft eigentlich die gesamte Kommunikation ab?

                    Pumpenbox <-> Fernbedienung: Bluetooth?

                    Fernbedienung <-> Intex Cloud: WLAN. Wird da jede Zustandsänderung (z.B. Einschalten Filter) an die Cloud geschickt? Wer verwaltet den Scheduler, wenn sich z.B. der Sanitizer nach 3h ausschalten soll - die Cloud, die Fernbedienung oder die Pumpenbox?

                    Smartphone App: WLAN zur Fernbedienung oder geht alles nur über die Cloud? Im 2. Fall also etwa so: das Smartphone meldet sich in der Cloud an, sendet den Befehl aufgrund meines Fingerdrucks, die Cloud sendet das an die Fernbedienung bzw. alle angemeldeten Geräte? und die Fernbedienung gibt es an die Pumpenbox weiter.

                    Die App am Smartphone aktualisiert die Werte nur alle heiligen Zeiten oder wenn ich mich neu anmelde. Gibt es kein "Push", muss der aktuelle Status regelmässig abgefragt werden?

                    Bitte um Richtigstellung meiner zusammengereimten Vorstellung 😉

                    LG,
                    Gregor

                    PLCHome 0 2 Replies Last reply Reply Quote 0
                    • PLCHome 0
                      PLCHome 0 Developer @grex1975 last edited by PLCHome 0

                      @grex1975
                      Die App kommuniziert mir der Cloud.
                      Die Cloud kommuniziert mit dem WLAN-Empfänger im Pool.
                      Ich meine, der sitzt im Bedienteil.
                      Der WLAN-Empfänger im Pool wiederum mit dem Bedienteil oder der Steuerplatine.
                      Bedienteil und Steuerplatine kommunizieren über einen Serielumsetzer im 2.4 GHz Band untereinander.

                      Aufgrund der Laufzeiten gehe ich davon aus:
                      Die App sendet eine Anfrage an die Cloud,
                      Die Cloud fragt den WLAN-Empfänger im Pool ab.
                      Ob der nun die Daten vorhält oder bei der Steuerung abfragt, weiß ich nicht.
                      Der WLAN-Empfänger im Pool sendet die Zustände an die Cloud.
                      Die Cloud wiederum an die App.

                      Das Protokoll des Seriellumsetzers ist auch geknackt, hier gibt es einen MQTT Umsetzer für ältere Pools ohne WLAN, funktioniert aber auch mit den NEUEN Pools, da an der Kommunikation zwischen Bedienteil und Pool nichts geändert wurde:
                      https://github.com/Yogui79/IntexPureSpa

                      Das läuft übrigens flüssiger als die APP von Intex 🙂

                      G T 2 Replies Last reply Reply Quote 0
                      • PLCHome 0
                        PLCHome 0 Developer @grex1975 last edited by

                        @tombox
                        Mir ist gestern ein Problem mit dem Control aufgefallen. Es kommt durch die Laufzeit:

                        Wenn ich schalte und kurz vorher der Status abgefragt wurde, wird von der Cloud noch der alte Status zurückgegeben.
                        Dann fängt er an zu toggeln. Ich hab aber schon eine quick Lösung: Sid muss kleiner sein as die Zeit, zu der geschaltet wurde.

                        Es soll den Jet ausschalten und sieht ihn immer nur als "Ein", da die Cloud immer abwechselnd den alten und den Neunen Status zurückgibt.

                        2022-06-02 23:20:16.507 - debug: intex.0 (11783) {"deviceId":"e8fa6219-64f7-4aa2-bac4-************","sessionId":"1654204815878","iotDataType":"C2DCommand","c2DCommandStatus":"Sended"}
                        2022-06-02 23:20:19.037 - debug: intex.0 (11783) {"deviceId":"e8fa6219-64f7-4aa2-bac4-************","sessionId":"1654204818461","iotDataType":"C2DCommand","c2DCommandStatus":"Sended"}
                        2022-06-02 23:20:37.067 - debug: intex.0 (11783) {"sid":"1654204815878","type":2,"result":"ok","data":"FFFF110F010B001E0000000080808023000011"}
                        2022-06-02 23:20:37.126 - debug: intex.0 (11783) send:8888060F011000C8
                        2022-06-02 23:20:37.726 - debug: intex.0 (11783) {"deviceId":"e8fa6219-64f7-4aa2-bac4-************","sessionId":"1654204837128","iotDataType":"C2DCommand","c2DCommandStatus":"Sended"}
                        2022-06-02 23:20:39.465 - debug: intex.0 (11783) {"sid":"1654204818461","type":2,"result":"ok","data":"FFFF110F010B001E0000000080808023000011"}
                        2022-06-02 23:20:39.506 - debug: intex.0 (11783) send:8888060F011000C8
                        2022-06-02 23:20:40.077 - debug: intex.0 (11783) {"deviceId":"e8fa6219-64f7-4aa2-bac4-************","sessionId":"1654204839506","iotDataType":"C2DCommand","c2DCommandStatus":"Sended"}
                        2022-06-02 23:20:50.716 - debug: intex.0 (11783) {"deviceId":"e8fa6219-64f7-4aa2-bac4-************","sessionId":"1654204850078","iotDataType":"C2DCommand","c2DCommandStatus":"Sended"}
                        2022-06-02 23:21:11.238 - debug: intex.0 (11783) {"sid":"1654204850078","type":2,"result":"ok","data":"FFFF110F010B001E0000000080808023000011"}
                        2022-06-02 23:21:11.297 - debug: intex.0 (11783) send:8888060F011000C8
                        2022-06-02 23:21:11.893 - debug: intex.0 (11783) {"deviceId":"e8fa6219-64f7-4aa2-bac4-************","sessionId":"1654204871298","iotDataType":"C2DCommand","c2DCommandStatus":"Sended"}
                        2022-06-02 23:21:13.043 - debug: intex.0 (11783) send:8888060F011000C8
                        2022-06-02 23:21:13.608 - debug: intex.0 (11783) {"deviceId":"e8fa6219-64f7-4aa2-bac4-************","sessionId":"1654204873045","iotDataType":"C2DCommand","c2DCommandStatus":"Sended"}
                        2022-06-02 23:21:19.129 - debug: intex.0 (11783) {"deviceId":"e8fa6219-64f7-4aa2-bac4-************","sessionId":"1654204878461","iotDataType":"C2DCommand","c2DCommandStatus":"Sended"}
                        2022-06-02 23:21:24.276 - debug: intex.0 (11783) {"deviceId":"e8fa6219-64f7-4aa2-bac4-************","sessionId":"1654204883609","iotDataType":"C2DCommand","c2DCommandStatus":"Sended"}
                        2022-06-02 23:21:39.618 - debug: intex.0 (11783) {"sid":"1654204878461","type":2,"result":"ok","data":"FFFF110F010B001E0000000080808023000011"}
                        2022-06-02 23:21:39.695 - debug: intex.0 (11783) send:8888060F011000C8
                        2022-06-02 23:21:40.277 - debug: intex.0 (11783) {"deviceId":"e8fa6219-64f7-4aa2-bac4-************","sessionId":"1654204899696","iotDataType":"C2DCommand","c2DCommandStatus":"Sended"}
                        2022-06-02 23:21:44.711 - debug: intex.0 (11783) {"sid":"1654204883609","type":2,"result":"ok","data":"FFFF110F010B001E0000000080808023000011"}
                        2022-06-02 23:21:44.797 - warn : intex.0 (11783) Cannot set control e8fa6219-64f7-4aa2-bac4-************.control.Jet to false
                        2022-06-02 23:21:51.284 - debug: intex.0 (11783) {"deviceId":"e8fa6219-64f7-4aa2-bac4-************","sessionId":"1654204910279","iotDataType":"C2DCommand","c2DCommandStatus":"Sended"}
                        

                        Ich würde die Zustandsabfrage gerne umbauen, aktuell gibt es einen Time-out und einen zyklischen Timer. Ich hätte gerne einen Timeout der nach der Eingestellten zeit läuft, auf Time-out prüft und dann nach Intervall - Time-out neu startet.
                        Nach dem Schalten sollte die Zeit zur nächsten anfrage verkürzt werden und dann wieder in den Zyklus gewechselt werden.

                        1 Reply Last reply Reply Quote 0
                        • PLCHome 0
                          PLCHome 0 Developer @grex1975 last edited by PLCHome 0

                          @grex1975

                          Also bei mir gehts, ack muss fals sein:

                          let autoheat = false
                          const pvSOC='growatt.0.359213.devices.NNCJA2400C.statusData.SOC'/*Soc*/;
                          
                          const poolPower = "intex.0.e8fa6219-64f7-4aa2-bac4-xxxxx.control.Power"
                          const poolHeat = "intex.0.e8fa6219-64f7-4aa2-bac4-xxxxx.control.Heat"
                          const poolSanitzer = "intex.0.e8fa6219-64f7-4aa2-bac4-xxxxx.control.Sanitizer"
                          
                          start()
                          async function start() {
                              let state = await getStateAsync(pvSOC);
                              doHeat(state);
                          }
                          on({id: pvSOC, change: "ne"},(obj)=>{doHeat(obj.state)});
                          async function doHeat(state) {
                              if (state.val >= 85 && !autoheat) {
                                  setState(poolPower,true,false);
                                  setState(poolSanitzer,false,false);
                                  
                                  setTimeout(async ()=>{
                                      setState(poolHeat,true,false);
                                      autoheat = true;
                                  },1000)
                                  log ('on')
                                  sendTo("email.0", {
                                      //from:    "iobroker@mydomain.com",
                                      //to:      "aabbcc@gmail.com, xxyyzz@gmail.com", // comma separated multiple recipients.
                                      subject: "Es ist viel Sonne am Himmel",
                                      text:    "Der Pool wird geheitzt..."
                                  });
                              } else if (state.val < 80 && autoheat) {
                                  autoheat = false;
                                  setState(poolHeat,false);
                                  sendTo("email.0", {
                                      //from:    "iobroker@mydomain.com",
                                      //to:      "aabbcc@gmail.com, xxyyzz@gmail.com", // comma separated multiple recipients.
                                      subject: "Die Sonne geht weg",
                                      text:    "Die Poolheizung wird abgestellt..."
                                  });
                              }
                          };
                          
                          PLCHome 0 1 Reply Last reply Reply Quote 0
                          • PLCHome 0
                            PLCHome 0 Developer @PLCHome 0 last edited by

                            Überwachung 🙂

                            af47336f-7e18-4cb6-8d50-521ccbcdeef8-image.png

                            G 1 Reply Last reply Reply Quote 0
                            • G
                              grex1975 @PLCHome 0 last edited by

                              @plchome-0 said in Test Intext App v0.0.x:

                              @grex1975
                              https://github.com/Yogui79/IntexPureSpa

                              Das läuft übrigens flüssiger als die APP von Intex 🙂

                              Danke für die Info.
                              Die App finde ich auch sehr behäbig. Muss mich außerdem für jede Aktion einloggen, was zusätzlich lange dauert.
                              Meine Intex-Fernbedienung ist ziemlich wasserempfindlich - ein paar Tropfen und sie spinnt für die nächsten 24h.
                              Will den Whirlpool aber nicht schlecht machen, die ganze Familie hat Spass damit 🙂 Möchte nur die Bedienung anpassen.
                              Ich werde das mit dem ESP32 ausprobieren. Wenn es funktioniert, kann ich z.B. für die Kinder 2 Knöpfe machen - Jet für 10 Min ein und Blubberblasen für 10 Min ein 🙂

                              Wie oft fragt der iobroker Adapter den Status über die cloud ab?

                              LG,
                              Gregor

                              PLCHome 0 1 Reply Last reply Reply Quote 0
                              • G
                                grex1975 @PLCHome 0 last edited by

                                @plchome-0 coole Grafik 🙂
                                meine ist etwas klobiger:

                                9d2c452b-889f-432f-8770-169494db3957-grafik.png

                                1 Reply Last reply Reply Quote 0
                                • PLCHome 0
                                  PLCHome 0 Developer @grex1975 last edited by PLCHome 0

                                  @grex1975 said in Test Intext App v0.0.x:

                                  Wie oft fragt der iobroker Adapter den Status über die cloud ab?

                                  Das liegt an deiner (inneren) Einstellung ich hab 1 eingestellt 🙂

                                  460766a7-5e26-49f9-b274-f29d821aef6d-image.png

                                  Meine Intex-Fernbedienung ist ziemlich wasserempfindlich - ein paar Tropfen und sie spinnt für die nächsten 24h.

                                  Mit der Fernbedienung hatte ich noch keine Wasserprobleme, die ist bei uns immer in der Halterung, wenn wir drinsitzen, allerdings nehme ich die morgens aus der Ladeschale, wenn es warm wird. Da steht die Sonne drauf und der alte Pool ist schon mal ausgestiegen, weil dem Bedienteil zu warm war. Nachts ist die in der Ladeschale auch bei Regen. Weder an meinem Alten noch an dem neuen Pool hatte wir Feuchtigkeitsprobleme.

                                  Wir hatten 2 Jahre einen kleinen 750l ohne WLAN und ich hab jetzt den gleichen mit 1m³ und WLAN bestellt.

                                  Das Projekt mit dem ESP hatte ich zu spät gefunden. Komisch ist, dass man dort dreimal den ESP bespielen muss.
                                  Die Teile hab ich da, wenn ich Zeit habe, werde ich das mal ausprobieren.

                                  Wenn es funktioniert, kann ich z.B. für die Kinder 2 Knöpfe machen - Jet für 10 Min ein und Blubberblasen für 10 Min ein

                                  Zigbee-Taster -> iobroker? oder tasmota.Taster -> MQTT -> iobroker -> Script?
                                  Ich hab den jetzt Pool über MQTT in der Homebridge darüber dann in Alexa und Handy.

                                  Mit Conbee/dconz ist aber auch ein Zigbee Taster von Xiaomi Aqara möglich, so was hab ich für die Zirkulation. In der Küche und im Bad Zigbee Taster drücken, Alexa sagt, es wurde gestartet und in 2min ist das Wasser warm. Bei 2x Drücken wird auch zur "Unzeit" der Speicher aufgeheizt.

                                  G D 2 Replies Last reply Reply Quote 0
                                  • PLCHome 0
                                    PLCHome 0 Developer @grex1975 last edited by

                                    @grex1975 said in Test Intext App v0.0.x:

                                    jetzt brauche ich noch das Schalten der Heizfunktion dann könnte ich die Heizung in Abhängigkeit der PV Anlage programmieren

                                    Ich hab gerade das korrigierte main.js eingeschickt, wenn du Github abrufst kannst loslegen 🙂
                                    Bin am WE erst wieder aus Mexico zurück und hatte auch gestern erst den Fehler bemerkt 🤓

                                    const poolPower = "intex.0.e8fa6219-64f7-4aa2-bac4-xxxxx.control.Power"
                                    const poolHeat = "intex.0.e8fa6219-64f7-4aa2-bac4-xxxxx.control.Heat"
                                    const poolSanitzer = "intex.0.e8fa6219-64f7-4aa2-bac4-xxxxx.control.Sanitizer"
                                    setState(poolPower,true,false);
                                    setState(poolSanitzer,false,false);
                                    setState(poolHeat,true,false);
                                    
                                    G 1 Reply Last reply Reply Quote 0
                                    • T
                                      tklein @tombox last edited by tklein

                                      @tombox

                                      Hi,

                                      nachdem ich bei der 0.6 Version nicht mehr schalten konnte und folgendes im Log sehen konnte:

                                      intex.0	2022-06-05 14:20:27.106	info	(3669) starting. Version 0.0.6 in /opt/iobroker/node_modules/iobroker.intex, node: v14.17.0, js-controller: 4.0.21
                                      intex.0	2022-06-05 14:19:51.174	warn	(1852) Terminated (UNCAUGHT_EXCEPTION): Without reason
                                      intex.0	2022-06-05 14:19:51.171	info	(1852) terminating
                                      intex.0	2022-06-05 14:19:51.143	error	(1852) Cannot read property 'toString' of undefined
                                      intex.0	2022-06-05 14:19:51.142	error	at Intex.onStateChange (/opt/iobroker/node_modules/iobroker.intex/main.js:581:37)
                                      intex.0	2022-06-05 14:19:51.142	error	(1852) TypeError: Cannot read property 'toString' of undefined
                                      intex.0	2022-06-05 14:19:51.137	error	(1852) unhandled promise rejection: Cannot read property 'toString' of undefined
                                      intex.0	2022-06-05 14:19:51.136	error	(1852) Unhandled promise rejection. This error originated either by throwing inside of an async function without a catch block, or by rejecting a promise which was not handled with .catch().
                                      intex.0	2022-06-05 14:15:05.598	error	(1852) {"code":404,"msg":"The device is not found in IOT Hub."}
                                      intex.0	2022-06-05 14:15:05.597	error	(1852) AxiosError: Request failed with status code 404
                                      
                                      

                                      habe ich vergeblich versucht auf die 0.7 zu updaten. Habe seit 5 min den Spinner bei der Installation per Githublink:

                                       iobroker url https://github.com/TA2k/ioBroker.intex --host raspberrypi-iob
                                      
                                      install TA2k/ioBroker.intex#600bfb66f1f4d1...
                                      
                                      NPM version: 6.14.13
                                      
                                      Installing TA2k/ioBroker.intex#600bf...ef... (System call)
                                      ERROR: Process exited with code 25
                                      

                                      Per App kann ich schalten. Was kann ich machen?
                                      Adapter selbst ist grün.

                                      Grüße und schöne Pfingsten
                                      Thomas

                                      PLCHome 0 2 Replies Last reply Reply Quote 0
                                      • T
                                        tklein @grex1975 last edited by

                                        @grex1975 said in Test Intext App v0.0.x:

                                        @plchome-0 Whirlpool Pure-Spa Bubble & Jet - Groß, ist ein Salzwassersystem, werde es aber auch mal mit Wasserstoffperoxid probieren.

                                        Value5=Active Action, Value7=Current Temperature, Value15=Goal Temperature
                                        Hat schon jemand den Sinn der anderen Values herausgefunden?

                                        Value 7 = Isttemperatur
                                        Value 15 = Wunschtemperatur

                                        1 Reply Last reply Reply Quote 0
                                        • PLCHome 0
                                          PLCHome 0 Developer @tklein last edited by PLCHome 0

                                          @tklein Benutze control zum Schalten, das sollte gehen, solange der Status synchronisiert ist.
                                          Die Temperaturen setehn auch korrekt unter Control.
                                          Ich kann natürlich nur für meinen Pool sprechen. (Salzwasser mit Jet und Bubbeln)

                                          T 1 Reply Last reply Reply Quote 0
                                          • T
                                            tklein @PLCHome 0 last edited by

                                            @plchome-0 thx, habe auch den mit Salz etc.

                                            Mit Control konnte ich den jetzt auch schalten. Gibt es auch irgendwo Updates, wenn ich per App oder Display schalte?

                                            PLCHome 0 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            790
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            17
                                            192
                                            19370
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo