      @meister-mopper
      Ich habe eine EVBox Elvi erfolgreich mit dem Adapter verbunden und kann einen Ladevorgang problemlos abbrechen.
      Nach Abbrechen über transAction = false erhalte ich den status Finishing

      Leider kann ich den Ladevorgang durch transAction = true und deaktivieren/reaktivieren der availability nicht wieder starten und bekomme:

      ocpp.0	2022-08-28 18:41:40.749	error	Cannot execute command "transactionActive" for "http://192_168_178_80:9220/EVB-XXXXXXXXXX": Sender's message does not comply with protocol specification.
      

      Jetzt könnte es noch an einem fehlerhaften idTag liegen:

      Ich habe das idTag erfolglos in verschiedenen Versionen eingegeben

      <NL-EVB-CXXXXXXXX-F>
      oder
      <CXXXXXXXX>
      oder
      <CXXXXXXXX-F>
      oder
      <NL-EVB-CXXXXXXXX>

      Weiteres:
      Nachdem ich einen Ladevorgang abgebrochen habe (Finished), ist die Wallbox für den Adapter tot und reagiert nicht mehr auf irgendwas.
      Ich muss dann das Ladekabel ziehen, wieder einstecken und mit dem RFID Chip aktivieren. Dann wird wieder geladen, und ich kann problemlos das Laden auch wieder unterbrechen.

      Manchmal steht man millimeternah vorm Scheunentor, vielleicht ist jemand weiter entfernt.

      So sieht es nach dem Beenden des Ladevorgangs aus:

      57f69c37-962d-4e58-83c2-20260b1c0071-grafik.png

      @foxriver76
      Hier mal die Zeilen im debug log, nachdem ich transactionActive = true gesetzt habe:

      ocpp.0	2022-09-02 15:30:29.860	error	Cannot execute command "transactionActive" for "http://192_168_178_80:9220/EVB-xxxxxxxxxx": Sender's message does not comply with protocol specification.
      ocpp.0	2022-09-02 15:30:29.573	debug	Sending RemoteStartTransaction for http://192_168_178_80:9220/EVB-xxxxxxxxxx: {"connectorId":1,"idTag":"xxxxxxxxxxxxxx","chargingProfile":{"chargingProfileId":1,"stackLevel":0,"chargingProfilePurpose":"TxDefaultProfile","chargingProfileKind":"Recurring","recurrencyKind":"Daily","chargingSchedule":{"duration":86400,"startSchedule":"2013-01-01T00:00Z","chargingRateUnit":"A","chargingSchedulePeriod":[{"startPeriod":0,"limit":16}]}}}
      

      Vielleicht hast Du ja eine Idee, welche Informationen der Wallbox noch fehlen.

      1 Reply Last reply Reply Quote 0
      • T
        Tiedi last edited by

        Ich versuche meinen ganz neuen NRGkick per ocpp mit diesem Adapter zu verbinden. Leider bisher ohne Erfolg. Stimmt was an den Einstellungen in der NRG App nicht? Hat da jemand Erfahrung?

        Screenshot_20220829-080736_NRGkick.jpg

        Nator 1 Reply Last reply Reply Quote 0
        • Nator
          Nator @Tiedi last edited by

          @tiedi
          Versuche mal ws://... statt http://...

          1 Reply Last reply Reply Quote 0
          • T
            Tiedi last edited by

            Leider nein.

            Keine Verbindung möglich. Habe au h schon mit der Authentifizierung alles probiert.

            Keine Verbindung. Er lädt aber wesentlich länger, wenn ich es mit WS mache.

            1 Reply Last reply Reply Quote 0
            • T
              Tiedi last edited by

              Kann ich denn irgendwo ein Fehlerprotokoll sehen, um zu checken, was bei der Verbindung schief läuft?
              In iobroker unter Protokoll erscheint nichts dazu.

              Meister Mopper 1 Reply Last reply Reply Quote 0
              • Meister Mopper
                Meister Mopper @Tiedi last edited by

                @foxriver76
                Der aktuelle Stand ist, dass ich jetzt vermittels des Adapters Ladevorgänge nicht mehr beenden kann.

                Am System habe ich nichts verändert. Das log wirft nach transactiveFalse folgendes:

                ocpp.0	2022-09-07 18:15:26.683	info	New valid connection from "http://192.168.178.80:9220/XXXXXXXXX" (http/ocpp1.6)
                ocpp.0	2022-09-07 18:15:26.738	info	New device connected: "http://192.168.178.80:9220/XXXXXXXXX"
                ocpp.0	2022-09-07 18:15:26.740	info	Requesting BootNotification from "http://192.168.178.80:9220/XXXXXXXXX"
                ocpp.0	2022-09-07 18:15:27.778	info	Requesting StatusNotification from "http://192.168.178.80:9220/XXXXXXXXX"
                ocpp.0	2022-09-07 18:15:31.785	info	Received boot notification from "http://192.168.178.80:9220/XXXXXXXXX"
                ocpp.0	2022-09-07 18:15:32.108	info	Received Status Notification from "http://192.168.178.80:9220/XXXXXXXXX": Available
                ocpp.0	2022-09-07 18:15:36.708	info	Received DataTransfer from "http://192.168.178.80:9220/XXXXXXXXX" with id "evbStatusNotification": 1,Available,NoError,No error.,0,Green,0,{0,7984,100},{0,0},{A,11904,12024,61568},0,0,430,2022-09-07T16:15:31Z,0,3,{0,0,0,0,0,0,0,0,0},350,0,2,112,0,370,900,0
                ocpp.0	2022-09-07 18:15:57.789	warn	Could not request states of "http://192.168.178.80:9220/XXXXXXXXX": Timeout for message bf60175d-e1cb-433d-b6ee-69f079b9950d
                

                Möglicherweise ist meine Wallbox jetzt im Reaktionsverhalten langsamer geworden? I have no eaning (😊 )

                foxriver76 1 Reply Last reply Reply Quote 0
                • foxriver76
                  foxriver76 Developer @Meister Mopper last edited by

                  @meister-mopper hm im log sieht man nur die neue Connection

                  Meister Mopper 1 Reply Last reply Reply Quote 0
                  • Meister Mopper
                    Meister Mopper @foxriver76 last edited by Meister Mopper

                    @foxriver76
                    Sorry. Möchtest Du das debug log sehen?

                    Ja klar, liefere ich morgen nach.

                    foxriver76 1 Reply Last reply Reply Quote 0
                    • foxriver76
                      foxriver76 Developer @Meister Mopper last edited by foxriver76

                      @meister-mopper Ja genau, der Befehl der raus geht sollte im Debug zu sehen sein. Das ist dann hilfreich. Sorry, bin in letzter Zeit etwas kurz angebunden.

                      Also wenn er den Ladevorgang nicht beendet, dann sollte ja im Log zumindest die transactionActive=false generierte Message sein und der Payload dazu, auf debug vermute ich nur.

                      Meister Mopper 1 Reply Last reply Reply Quote 0
                      • W
                        Watchdog last edited by Watchdog

                        @all Danke für dieses geile OCPP!

                        1 Reply Last reply Reply Quote 0
                        • Meister Mopper
                          Meister Mopper @foxriver76 last edited by Meister Mopper

                          @foxriver76

                          Sehr seltsam, jetzt geht das Beenden des Ladevorgangs wieder. Der Ladestart funktioniert allerdings noch immer nicht.

                          Vielleicht hilft das debug log:

                          ocpp.0	2022-09-16 17:22:28.232	debug	Sending RemoteStopTransaction for http://192_168_178_80:9220/EVB-XXXXXXXXX
                          ocpp.0	2022-09-16 17:22:33.723	debug	{"transactionId":1,"idTag":"XXXXXXXXX","timestamp":"2022-09-16T15:22:33Z","meterStop":0,"reason":"Remote","commandOcpp":"StopTransaction"}
                          ocpp.0	2022-09-16 17:22:33.724	info	Received stop transaction from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
                          ocpp.0	2022-09-16 17:22:34.386	debug	{"connectorId":1,"status":"Finishing","errorCode":"NoError","timestamp":"2022-09-16T15:22:34Z","commandOcpp":"StatusNotification"}
                          ocpp.0	2022-09-16 17:22:34.387	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": Finishing
                          ocpp.0	2022-09-16 17:22:38.324	debug	{"vendorId":"EV-BOX","messageId":"evbStatusNotification","data":"1,Finishing,NoError,No error.,0,Green,0,{20,7984,100},{0,0},{C,11935,6140,61600},0,0,340,2022-09-16T15:22:34Z,0,3,{0,0,0,0,0,0,0,0,0},270,9,2,113,0,320,900,0","commandOcpp":"DataTransfer"}
                          ocpp.0	2022-09-16 17:22:38.325	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,Finishing,NoError,No error.,0,Green,0,{20,7984,100},{0,0},{C,11935,6140,61600},0,0,340,2022-09-16T15:22:34Z,0,3,{0,0,0,0,0,0,0,0,0},270,9,2,113,0,320,900,0
                          ocpp.0	2022-09-16 17:22:52.300	debug	{"commandOcpp":"Heartbeat"}
                          ocpp.0	2022-09-16 17:22:52.301	debug	Received heartbeat from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
                          ocpp.0	2022-09-16 17:27:42.613	debug	Sending RemoteStartTransaction for http://192_168_178_80:9220/EVB-XXXXXXXXX: {"connectorId":1,"idTag":"XXXXXXXXX","chargingProfile":{"chargingProfileId":1,"stackLevel":0,"chargingProfilePurpose":"TxDefaultProfile","chargingProfileKind":"Recurring","recurrencyKind":"Daily","chargingSchedule":{"duration":86400,"startSchedule":"2013-01-01T00:00Z","chargingRateUnit":"A","chargingSchedulePeriod":[{"startPeriod":0,"limit":16}]}}}
                          ocpp.0	2022-09-16 17:27:42.920	error	Cannot execute command "transactionActive" for "http://192_168_178_80:9220/EVB-XXXXXXXXX": Sender's message does not comply with protocol specification.
                          
                          foxriver76 2 Replies Last reply Reply Quote 0
                          • foxriver76
                            foxriver76 Developer @Meister Mopper last edited by

                            @meister-mopper ohje, ich verstehe es nicht ganz. Die Kommandos ändern sich ja nicht.

                            War da zwischenrein ein Update der WB?

                            Meister Mopper 1 Reply Last reply Reply Quote 0
                            • foxriver76
                              foxriver76 Developer @Meister Mopper last edited by foxriver76

                              @meister-mopper sagte in Alpha Testing: OCPP Wallbox Adapter:

                              Sender's message does not comply with protocol specification.

                              Das scheint keine interne Fehlermeldung einer Lib zu sein, da scheint der WB wirklich das Command nicht zu passen welches wir senden.

                              Hast du evtl. auf WB Seite ein Log das mehr Infos gibt, was genau nicht valide ist an dem Kommando?

                              1 Reply Last reply Reply Quote 0
                              • Meister Mopper
                                Meister Mopper @foxriver76 last edited by

                                @foxriver76 sagte in Alpha Testing: OCPP Wallbox Adapter:

                                War da zwischenrein ein Update der WB?

                                Nein, zwischen dem Fehler beim Ladeschluss bis zum erneuten Funktionieren des Ladeschlusses gab es kein Update der WB.

                                Leider weiß ich nicht, wie ich ein log der WB einsehen könnte. Die App sieht so etwas nicht vor.

                                foxriver76 1 Reply Last reply Reply Quote 0
                                • foxriver76
                                  foxriver76 Developer @Meister Mopper last edited by foxriver76

                                  @meister-mopper falls du es dir zutraust ändere mal lokal die build/main.js) https://github.com/foxriver76/ioBroker.ocpp/blob/48303d5b08f18682ed681038d614133990a50c1e/build/main.js#L397 diese Zeile hier zu

                                  if (false) {

                                  Evtl gefällt ihm das profile nicht.

                                  Meister Mopper 1 Reply Last reply Reply Quote 0
                                  • Meister Mopper
                                    Meister Mopper @foxriver76 last edited by

                                    @foxriver76

                                    Du meinst

                                                    if ((limitState === null || limitState === void 0 ? void 0 : limitState.val) && typeof limitState.val === 'number') {
                                    

                                    in

                                    if (false) {((limitState === null || limitState === void 0 ? void 0 : limitState.val) && typeof limitState.val === 'number') {
                                    

                                    Aber wo setze ich dann das erforderliche }?

                                    Sorry, ich bin kein Programmierer.

                                    1 Reply Last reply Reply Quote 0
                                    • foxriver76
                                      foxriver76 Developer last edited by foxriver76

                                      Mach vor die existente Zeile einfach // und mach darunter das was ich geschrieben habe, ich kann es dir morgen am pc nochmal genauer schreiben.

                                      Meister Mopper 1 Reply Last reply Reply Quote 0
                                      • Meister Mopper
                                        Meister Mopper @foxriver76 last edited by

                                        @foxriver76
                                        Sehr gut, das funktioniert. Ich kann jetzt das Laden starten und beenden.

                                        foxriver76 1 Reply Last reply Reply Quote 0
                                        • foxriver76
                                          foxriver76 Developer @Meister Mopper last edited by

                                          @meister-mopper Interessant, was hast du denn in dem chargeLimit State drin stehen unter Objekte?

                                          Meister Mopper 2 Replies Last reply Reply Quote 0
                                          • Meister Mopper
                                            Meister Mopper @foxriver76 last edited by

                                            @foxriver76
                                            Da habe ich 16 A eingetragen, weiß aber nicht, ob das Ladelimit tatsächlich mit diesem Datenpunkt umzustellen ist.
                                            Das ist der Wert, der auch im Standard Backend der evBox definiert war. Es wird auch mit 16 A geladen.

                                            foxriver76 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            770
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            adapter ocpp wallbox
                                            48
                                            440
                                            78015
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo