NEWS
CCU nicht mehr ansprechbar
-
Ich betreibe ioBroker auf einem Raspi 3.
Außerdem ist die homematic CCU auf dem Raspi in einem Yahm Container installiert.
Seit Gestern habe ich folgende Fehlermeldung, die sich wiederholt.
IRgendeine Idee, was hier falsch sein könnte.
hm-rpc.0 2017-07-01 23:38:45.340 warn Cannot setValue "hm-rpc.0.KEQ0122349.4.STATE", because not connected. hm-rpc.0 2017-07-01 23:38:43.832 warn Cannot setValue "hm-rpc.0.KEQ0122349.4.STATE", because not connected. hm-rpc.0 2017-07-01 23:38:42.324 warn Cannot setValue "hm-rpc.0.KEQ0122349.4.STATE", because not connected. hm-rpc.0 2017-07-01 23:38:40.818 warn Cannot setValue "hm-rpc.0.KEQ0122349.4.STATE", because not connected. hm-rpc.0 2017-07-01 23:38:39.312 warn Cannot setValue "hm-rpc.0.KEQ0122349.4.STATE", because not connected. hm-rpc.0 2017-07-01 23:38:37.816 warn Cannot setValue "hm-rpc.0.KEQ0122349.4.STATE", because not connected. hm-rpc.0 2017-07-01 23:38:36.033 warn Cannot setValue "hm-rpc.0.KEQ0122349.4.STATE", because not connected. hm-rpc.0 2017-07-01 23:38:34.515 warn Cannot setValue "hm-rpc.0.KEQ0122349.4.STATE", because not connected. hm-rpc.0 2017-07-01 23:38:33.005 warn Cannot setValue "hm-rpc.0.KEQ0122349.4.STATE", because not connected. hm-rpc.0 2017-07-01 23:38:31.495 warn Cannot setValue "hm-rpc.0.KEQ0122349.4.STATE", because not connected. hm-rpc.0 2017-07-01 23:38:29.989 warn Cannot setValue "hm-rpc.0.KEQ0122349.4.STATE", because not connected. hm-rpc.0 2017-07-01 23:38:28.483 warn Cannot setValue "hm-rpc.0.KEQ0122349.4.STATE", because not connected. hm-rpc.0 2017-07-01 23:38:26.978 warn Cannot setValue "hm-rpc.0.KEQ0122349.4.STATE", because not connected. hm-rpc.0 2017-07-01 23:38:26.098 info Disconnected hm-rpc.0 2017-07-01 23:38:26.097 error Ping error: Error: not connected hm-rpc.0 2017-07-01 23:38:25.472 error Error: not connected hm-rpc.0 2017-07-01 23:38:25.471 error binrpc -> setValue ["4","STATE",false] BOOL hm-rpc.0 2017-07-01 23:38:23.966 error Error: not connected hm-rpc.0 2017-07-01 23:38:23.966 error binrpc -> setValue ["4","STATE",false] BOOL hm-rpc.0 2017-07-01 23:38:22.461 error Error: not connected hm-rpc.0 2017-07-01 23:38:22.460 error binrpc -> setValue ["4","STATE",false] BOOL hm-rpc.0 2017-07-01 23:38:20.954 error Error: not connected hm-rpc.0 2017-07-01 23:38:20.954 error binrpc -> setValue ["4","STATE",false] BOOL hm-rpc.0 2017-07-01 23:38:19.449 error Error: not connected hm-rpc.0 2017-07-01 23:38:19.449 error binrpc -> setValue ["4","STATE",false] BOOL hm-rpc.0 2017-07-01 23:38:17.943 error Error: not connected hm-rpc.0 2017-07-01 23:38:17.942 error binrpc -> setValue ["4","STATE",false] BOOL
-
Habe meinen Fehler gefunden!
Ich hatte eine Schleife, die permanent an einen Autor gesendet hat.
Mit dem super praktischen Ereignis Tab und der Filtermöglichkeiten war der Fehler gut zu identifizieren.