    • bahnuhr
      bahnuhr Forum Testing Most Active @Homoran last edited by

      @homoran sagte in Phasen des Hauses überwachen:

      @bahnuhr mach mal den debug aktiv

      ja, hätte ich auch selber drauf können.

      anbei:

      modbus.0
      2022-10-04 20:37:38.592	debug	Closing client on purpose.
      
      modbus.0
      2022-10-04 20:37:37.591	debug	Cleaning up request fifo.
      
      modbus.0
      2022-10-04 20:37:37.590	debug	Socket closed with error
      
      modbus.0
      2022-10-04 20:37:37.580	info	Disconnected from slave 192.168.243.31
      
      modbus.0
      2022-10-04 20:37:37.578	debug	Closing client on purpose.
      
      modbus.0
      2022-10-04 20:37:37.576	info	Connected to slave 192.168.243.31
      
      modbus.0
      2022-10-04 20:37:37.035	info	starting. Version 5.0.5 in /opt/iobroker/node_modules/iobroker.modbus, node: v16.17.1, js-controller: 4.0.23
      
      modbus.0
      2022-10-04 20:37:36.411	debug	Plugin sentry Initialize Plugin (enabled=true)
      

      Viel kommt da aber nicht.

      1 Reply Last reply Reply Quote 0
      • Glasfaser
        Glasfaser @bahnuhr last edited by Glasfaser

        @bahnuhr sagte in Phasen des Hauses überwachen:

        Daten eingegeben (so wie ich dachte)

        Zeige mal ein Screenshot ... ist auch ein Haken bei Poll ( Abfrage ) gesetzt , da im Debug nichts abgefragt wird

        bahnuhr 1 Reply Last reply Reply Quote 0
        • bahnuhr
          bahnuhr Forum Testing Most Active @Glasfaser last edited by

          @glasfaser
          vircom findet das device; anbei die config:
          f1bee4ff-9d75-4bb5-a3ed-0331d5e43cfc-image.png

          und die config vom modbus:
          5ea3a8a9-88b3-439e-9707-57181fb14604-image.png

          hatte auch schon probiert mit "mehrere id"
          und die geräte id auch schon geändert.

          Weiterhin benutze ich den adapter mbus um meinen Wasserzähler auszulesen.
          kann es sein, dass diese beide sich stören ?

          Glasfaser M 3 Replies Last reply Reply Quote 0
          • Glasfaser
            Glasfaser @bahnuhr last edited by

            @bahnuhr

            Bei mir funktioniert der gleiche waveshare

            nur mit RTU over TCP , bei TCP habe nie eine Verbindung bekommen / Auslesung

            7b7efb0b-ef3a-4737-8e40-ff30775c85eb-grafik.png

            Ich nutze nur Holding Register mit meinen Zählern , deiner wird mit Eingangsregister abgefragt wie ich oben erlese , hast du dort schon was eingetragen , laut der Vorlage !?

            bahnuhr 1 Reply Last reply Reply Quote 0
            • bahnuhr
              bahnuhr Forum Testing Most Active @Glasfaser last edited by

              @glasfaser
              kannst du mir die Einstellungen von deinem waveshare mal zeigen.

              @glasfaser sagte in Phasen des Hauses überwachen:

              Ich nutze nur Holding Register mit meinen Zählern , deiner wird mit Eingangsregister abgefragt wie ich oben erlese

              wo sieht man dies?

              Vielleicht kann ich deine Einstellungen ja nachstellen

              Glasfaser 1 Reply Last reply Reply Quote 0
              • M
                mane444 @bahnuhr last edited by

                @bahnuhr Die Einstellungen sehen gut aus. Aber wie @Glasfaser schon geschrieben hat, wenn im Eingangsregister nichts oder was falsches eingetragen ist kann das zu Problemen führen.

                1 Reply Last reply Reply Quote 0
                • Glasfaser
                  Glasfaser @bahnuhr last edited by

                  @bahnuhr sagte in Phasen des Hauses überwachen:

                  kannst du mir die Einstellungen von deinem waveshare mal zeigen.

                  Waveshare .png

                  wo sieht man dies?

                  5835f3af-be58-42fc-b7ff-9e07a586d7a9-grafik.png

                  Vielleicht kann ich deine Einstellungen ja nachstellen

                  Nein , ich habe andere Zähler die haben ein ganz anders Register ( Holding ) , das passt nicht mit deinem Zähler .

                  1 Reply Last reply Reply Quote 1
                  • M
                    mane444 @bahnuhr last edited by

                    @bahnuhr Hier die Einstellungen die ich bei mir habe als Screenshot. d1a3b2a7-7023-461d-97b5-8ba76f452576-image.png
                    Beachte die SlaveID, die ist bei neuen Geräten normalerweise auf 1. Evtl auch am Zähler mal kontrollieren ob die Schnittstellenparameter richtig sind.
                    a6f224ec-506c-4cf1-879e-26b974b1d058-image.png

                    Glasfaser 1 Reply Last reply Reply Quote 1
                    • Glasfaser
                      Glasfaser @mane444 last edited by Glasfaser

                      @mane444 sagte in Phasen des Hauses überwachen:

                      auch am Zähler mal kontrollieren ob die Schnittstellenparameter richtig sind.

                      Habe gerade mal auf der Homepage geschaut ... dort gibt es auch ein Tool zum Prüfen .

                      6966fd96-c1b7-472b-b6c2-c1d6a509965b-grafik.png

                      bahnuhr 1 Reply Last reply Reply Quote 1
                      • bahnuhr
                        bahnuhr Forum Testing Most Active @Glasfaser last edited by

                        @glasfaser
                        ja, mit dem wintool bekomme ich Infos:
                        43162c9f-b25d-4f58-a7f9-b71a2f26c53a-image.png

                        1 Reply Last reply Reply Quote 0
                        • bahnuhr
                          bahnuhr Forum Testing Most Active last edited by

                          Irgendwie klappt dies nicht.
                          Per vircom hab ich folgendes eingestellt:
                          69877051-13bd-4e3d-a41b-d407ebfa7436-image.png
                          Wo gibt man da die ID 1 ein ?
                          Oder ist das automatisch vergeben.

                          In modbus folgendes eingegeben:
                          4d26dd4a-e4e3-4bee-87f5-6afc9c143c3d-image.png
                          8b00e019-6a82-4e93-adf2-bfa72cb44381-image.png

                          Dann Instanz gestartet, im log (debug) kommt dann:

                          modbus.0
                          2022-10-05 09:24:48.332	info	Disconnected from slave 192.168.243.31
                          
                          modbus.0
                          2022-10-05 09:24:48.331	debug	Closing client on purpose.
                          
                          modbus.0
                          2022-10-05 09:24:47.350	debug	Cleaning up request fifo.
                          
                          modbus.0
                          2022-10-05 09:24:47.349	debug	Clearing timeout of the current request.
                          
                          modbus.0
                          2022-10-05 09:24:47.348	debug	Socket closed with error
                          
                          modbus.0
                          2022-10-05 09:24:47.333	warn	Poll error count: 1 code: {"err":"timeout","timeout":5000}
                          
                          modbus.0
                          2022-10-05 09:24:47.331	error	Client in error state.
                          
                          modbus.0
                          2022-10-05 09:24:47.331	error	Request timed out.
                          
                          modbus.0
                          2022-10-05 09:24:47.330	warn	Error: undefined
                          
                          modbus.0
                          2022-10-05 09:24:42.327	debug	Sending pdu to the socket.
                          
                          modbus.0
                          2022-10-05 09:24:42.325	debug	[DevID_1/inputRegs] Poll address 0 - 2 registers
                          
                          modbus.0
                          2022-10-05 09:24:42.324	debug	Initialization of scale factors done!
                          
                          modbus.0
                          2022-10-05 09:24:42.322	debug	[DevID_1] Poll start ---------------------
                          
                          modbus.0
                          2022-10-05 09:24:42.320	info	Connected to slave
                          
                          modbus.0
                          2022-10-05 09:24:41.740	debug	Initialize Objects for holdingRegs: []
                          
                          modbus.0
                          2022-10-05 09:24:41.740	debug	Add inputRegisters.1.31283_Wirkleistung_Einspeisung_Total: {"_id":"inputRegisters.1.31283_Wirkleistung_Einspeisung_Total","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":false,"def":0,"unit":"W"},"native":{"regType":"inputRegs","address":1282,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1}}
                          
                          modbus.0
                          2022-10-05 09:24:41.739	debug	Add inputRegisters.1.31281_Wirkleistung_Bezug_Total: {"_id":"inputRegisters.1.31281_Wirkleistung_Bezug_Total","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":false,"def":0,"unit":"W"},"native":{"regType":"inputRegs","address":1280,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1}}
                          
                          modbus.0
                          2022-10-05 09:24:41.738	debug	Add inputRegisters.1.30001_Phase_1_power_factor_(1)_: {"_id":"inputRegisters.1.30001_Phase_1_power_factor_(1)_","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":false,"def":0,"unit":"V"},"native":{"regType":"inputRegs","address":0,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1}}
                          
                          modbus.0
                          2022-10-05 09:24:41.737	debug	Initialize Objects for inputRegs: [{"_address":30001,"deviceId":1,"name":"Phase 1 power factor (1).","description":"","unit":"V","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","cw":"","isScale":"","address":0,"id":"inputRegisters.1.30001_Phase_1_power_factor_(1)_"},{"_address":31281,"deviceId":1,"name":"Wirkleistung Bezug Total","description":"","unit":"W","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","cw":"","isScale":"","address":1280,"id":"inputRegisters.1.31281_Wirkleistung_Bezug_Total"},{"_address":31283,"deviceId":1,"name":"Wirkleistung Einspeisung Total","description":"","unit":"W","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","cw":"","isScale":"","address":1282,"id":"inputRegisters.1.31283_Wirkleistung_Einspeisung_Total"}]
                          
                          modbus.0
                          2022-10-05 09:24:41.736	debug	Initialize Objects for coils: []
                          
                          modbus.0
                          2022-10-05 09:24:41.735	debug	Initialize Objects for disInputs: []
                          
                          modbus.0
                          2022-10-05 09:24:41.395	info	starting. Version 5.0.5 in /opt/iobroker/node_modules/iobroker.modbus, node: v16.17.1, js-controller: 4.0.23
                          

                          Der läuft in ein timeout; bekommt offensichtlich keine Verbindung.
                          Irgendwas stimmt doch da mit den Einstellungen noch nicht.
                          Komisch.

                          1 Reply Last reply Reply Quote 0
                          • bahnuhr
                            bahnuhr Forum Testing Most Active last edited by

                            Ha, ich habs hinbekommen.
                            Musste in der Instanz auf "TCP" schalten; "RTU over TCP" hat nicht geklappt.

                            Jetzt muss ich irgendwo her noch die Adressen bekommen.
                            Um diese dann einzupflegen.

                            Homoran 1 Reply Last reply Reply Quote 0
                            • Homoran
                              Homoran Global Moderator Administrators @bahnuhr last edited by Homoran

                              @bahnuhr sagte in Phasen des Hauses überwachen:

                              Jetzt muss ich irgendwo her noch die Adressen bekommen.

                              Liste der Adressen steht in der Anleitung zum Zähler

                              z.b.
                              Screenshot_20221005-095825_Polaris Office.jpg

                              bahnuhr 1 Reply Last reply Reply Quote 0
                              • bahnuhr
                                bahnuhr Forum Testing Most Active @Homoran last edited by

                                @homoran sagte in Phasen des Hauses überwachen:

                                Liste der Adressen steht in der Anleitung zum Zähler

                                ja, das weiß ich.
                                Man kann die aber auch rein kopieren und hatte gehofft, dass jemand die Daten zur Verfügung stellt.

                                Die 2. Lösung wäre alles abzutippen.

                                Glasfaser M 2 Replies Last reply Reply Quote 0
                                • Glasfaser
                                  Glasfaser @bahnuhr last edited by

                                  @bahnuhr sagte in Phasen des Hauses überwachen:

                                  @homoran sagte in Phasen des Hauses überwachen:

                                  Liste der Adressen steht in der Anleitung zum Zähler

                                  ja, das weiß ich.
                                  Man kann die aber auch rein kopieren und hatte gehofft, dass jemand die Daten zur Verfügung stellt.

                                  Ist das nicht der Zähler , dort ist doch eine Vorlage dazu !?

                                  79dd7da2-83a9-4810-9d34-22f56d4e142a-grafik.png

                                  https://forum.iobroker.net/post/861590

                                  1 Reply Last reply Reply Quote 0
                                  • M
                                    mane444 @bahnuhr last edited by

                                    @bahnuhr Hi Liste hab ich im Post angehängt.
                                    Hier nochmal, nur mit einem Zähler Busadresse 1
                                    Modbus Register Vorlage.txt

                                    1 Reply Last reply Reply Quote 1
                                    • First post
                                      Last post

                                    Support us

                                    ioBroker
                                    Community Adapters
                                    Donate

                                    304
                                    Online

                                    31.7k
                                    Users

                                    79.8k
                                    Topics

                                    1.3m
                                    Posts

                                    3-phasen
                                    7
                                    40
                                    2035
                                    Loading More Posts
                                    • Oldest to Newest
                                    • Newest to Oldest
                                    • Most Votes
                                    Reply
                                    • Reply as topic
                                    Log in to reply
                                    Community
                                    Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                    The ioBroker Community 2014-2023
                                    logo