    Phasen des Hauses überwachen

    This topic has been deleted. Only users with topic management privileges can see it.
    • bahnuhr
      bahnuhr Forum Testing Most Active @Glasfaser last edited by

      @glasfaser
      vircom findet das device; anbei die config:
      f1bee4ff-9d75-4bb5-a3ed-0331d5e43cfc-image.png

      und die config vom modbus:
      5ea3a8a9-88b3-439e-9707-57181fb14604-image.png

      hatte auch schon probiert mit "mehrere id"
      und die geräte id auch schon geändert.

      Weiterhin benutze ich den adapter mbus um meinen Wasserzähler auszulesen.
      kann es sein, dass diese beide sich stören ?

      Glasfaser M 3 Replies Last reply Reply Quote 0
      • Glasfaser
        Glasfaser @bahnuhr last edited by

        @bahnuhr

        Bei mir funktioniert der gleiche waveshare

        nur mit RTU over TCP , bei TCP habe nie eine Verbindung bekommen / Auslesung

        7b7efb0b-ef3a-4737-8e40-ff30775c85eb-grafik.png

        Ich nutze nur Holding Register mit meinen Zählern , deiner wird mit Eingangsregister abgefragt wie ich oben erlese , hast du dort schon was eingetragen , laut der Vorlage !?

        bahnuhr 1 Reply Last reply Reply Quote 0
        • bahnuhr
          bahnuhr Forum Testing Most Active @Glasfaser last edited by

          @glasfaser
          kannst du mir die Einstellungen von deinem waveshare mal zeigen.

          @glasfaser sagte in Phasen des Hauses überwachen:

          Ich nutze nur Holding Register mit meinen Zählern , deiner wird mit Eingangsregister abgefragt wie ich oben erlese

          wo sieht man dies?

          Vielleicht kann ich deine Einstellungen ja nachstellen

          Glasfaser 1 Reply Last reply Reply Quote 0
          • M
            mane444 @bahnuhr last edited by

            @bahnuhr Die Einstellungen sehen gut aus. Aber wie @Glasfaser schon geschrieben hat, wenn im Eingangsregister nichts oder was falsches eingetragen ist kann das zu Problemen führen.

            1 Reply Last reply Reply Quote 0
            • Glasfaser
              Glasfaser @bahnuhr last edited by

              @bahnuhr sagte in Phasen des Hauses überwachen:

              kannst du mir die Einstellungen von deinem waveshare mal zeigen.

              Waveshare .png

              wo sieht man dies?

              5835f3af-be58-42fc-b7ff-9e07a586d7a9-grafik.png

              Vielleicht kann ich deine Einstellungen ja nachstellen

              Nein , ich habe andere Zähler die haben ein ganz anders Register ( Holding ) , das passt nicht mit deinem Zähler .

              1 Reply Last reply Reply Quote 1
              • M
                mane444 @bahnuhr last edited by

                @bahnuhr Hier die Einstellungen die ich bei mir habe als Screenshot. d1a3b2a7-7023-461d-97b5-8ba76f452576-image.png
                Beachte die SlaveID, die ist bei neuen Geräten normalerweise auf 1. Evtl auch am Zähler mal kontrollieren ob die Schnittstellenparameter richtig sind.
                a6f224ec-506c-4cf1-879e-26b974b1d058-image.png

                Glasfaser 1 Reply Last reply Reply Quote 1
                • Glasfaser
                  Glasfaser @mane444 last edited by Glasfaser

                  @mane444 sagte in Phasen des Hauses überwachen:

                  auch am Zähler mal kontrollieren ob die Schnittstellenparameter richtig sind.

                  Habe gerade mal auf der Homepage geschaut ... dort gibt es auch ein Tool zum Prüfen .

                  6966fd96-c1b7-472b-b6c2-c1d6a509965b-grafik.png

                  bahnuhr 1 Reply Last reply Reply Quote 1
                  • bahnuhr
                    bahnuhr Forum Testing Most Active @Glasfaser last edited by

                    @glasfaser
                    ja, mit dem wintool bekomme ich Infos:
                    43162c9f-b25d-4f58-a7f9-b71a2f26c53a-image.png

                    1 Reply Last reply Reply Quote 0
                    • bahnuhr
                      bahnuhr Forum Testing Most Active last edited by

                      Irgendwie klappt dies nicht.
                      Per vircom hab ich folgendes eingestellt:
                      69877051-13bd-4e3d-a41b-d407ebfa7436-image.png
                      Wo gibt man da die ID 1 ein ?
                      Oder ist das automatisch vergeben.

                      In modbus folgendes eingegeben:
                      4d26dd4a-e4e3-4bee-87f5-6afc9c143c3d-image.png
                      8b00e019-6a82-4e93-adf2-bfa72cb44381-image.png

                      Dann Instanz gestartet, im log (debug) kommt dann:

                      modbus.0
                      2022-10-05 09:24:48.332	info	Disconnected from slave 192.168.243.31
                      
                      modbus.0
                      2022-10-05 09:24:48.331	debug	Closing client on purpose.
                      
                      modbus.0
                      2022-10-05 09:24:47.350	debug	Cleaning up request fifo.
                      
                      modbus.0
                      2022-10-05 09:24:47.349	debug	Clearing timeout of the current request.
                      
                      modbus.0
                      2022-10-05 09:24:47.348	debug	Socket closed with error
                      
                      modbus.0
                      2022-10-05 09:24:47.333	warn	Poll error count: 1 code: {"err":"timeout","timeout":5000}
                      
                      modbus.0
                      2022-10-05 09:24:47.331	error	Client in error state.
                      
                      modbus.0
                      2022-10-05 09:24:47.331	error	Request timed out.
                      
                      modbus.0
                      2022-10-05 09:24:47.330	warn	Error: undefined
                      
                      modbus.0
                      2022-10-05 09:24:42.327	debug	Sending pdu to the socket.
                      
                      modbus.0
                      2022-10-05 09:24:42.325	debug	[DevID_1/inputRegs] Poll address 0 - 2 registers
                      
                      modbus.0
                      2022-10-05 09:24:42.324	debug	Initialization of scale factors done!
                      
                      modbus.0
                      2022-10-05 09:24:42.322	debug	[DevID_1] Poll start ---------------------
                      
                      modbus.0
                      2022-10-05 09:24:42.320	info	Connected to slave
                      
                      modbus.0
                      2022-10-05 09:24:41.740	debug	Initialize Objects for holdingRegs: []
                      
                      modbus.0
                      2022-10-05 09:24:41.740	debug	Add inputRegisters.1.31283_Wirkleistung_Einspeisung_Total: {"_id":"inputRegisters.1.31283_Wirkleistung_Einspeisung_Total","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":false,"def":0,"unit":"W"},"native":{"regType":"inputRegs","address":1282,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1}}
                      
                      modbus.0
                      2022-10-05 09:24:41.739	debug	Add inputRegisters.1.31281_Wirkleistung_Bezug_Total: {"_id":"inputRegisters.1.31281_Wirkleistung_Bezug_Total","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":false,"def":0,"unit":"W"},"native":{"regType":"inputRegs","address":1280,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1}}
                      
                      modbus.0
                      2022-10-05 09:24:41.738	debug	Add inputRegisters.1.30001_Phase_1_power_factor_(1)_: {"_id":"inputRegisters.1.30001_Phase_1_power_factor_(1)_","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":false,"def":0,"unit":"V"},"native":{"regType":"inputRegs","address":0,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1}}
                      
                      modbus.0
                      2022-10-05 09:24:41.737	debug	Initialize Objects for inputRegs: [{"_address":30001,"deviceId":1,"name":"Phase 1 power factor (1).","description":"","unit":"V","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","cw":"","isScale":"","address":0,"id":"inputRegisters.1.30001_Phase_1_power_factor_(1)_"},{"_address":31281,"deviceId":1,"name":"Wirkleistung Bezug Total","description":"","unit":"W","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","cw":"","isScale":"","address":1280,"id":"inputRegisters.1.31281_Wirkleistung_Bezug_Total"},{"_address":31283,"deviceId":1,"name":"Wirkleistung Einspeisung Total","description":"","unit":"W","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","cw":"","isScale":"","address":1282,"id":"inputRegisters.1.31283_Wirkleistung_Einspeisung_Total"}]
                      
                      modbus.0
                      2022-10-05 09:24:41.736	debug	Initialize Objects for coils: []
                      
                      modbus.0
                      2022-10-05 09:24:41.735	debug	Initialize Objects for disInputs: []
                      
                      modbus.0
                      2022-10-05 09:24:41.395	info	starting. Version 5.0.5 in /opt/iobroker/node_modules/iobroker.modbus, node: v16.17.1, js-controller: 4.0.23
                      

                      Der läuft in ein timeout; bekommt offensichtlich keine Verbindung.
                      Irgendwas stimmt doch da mit den Einstellungen noch nicht.
                      Komisch.

                      1 Reply Last reply Reply Quote 0
                      • bahnuhr
                        bahnuhr Forum Testing Most Active last edited by

                        Ha, ich habs hinbekommen.
                        Musste in der Instanz auf "TCP" schalten; "RTU over TCP" hat nicht geklappt.

                        Jetzt muss ich irgendwo her noch die Adressen bekommen.
                        Um diese dann einzupflegen.

                        Homoran 1 Reply Last reply Reply Quote 0
                        • Homoran
                          Homoran Global Moderator Administrators @bahnuhr last edited by Homoran

                          @bahnuhr sagte in Phasen des Hauses überwachen:

                          Jetzt muss ich irgendwo her noch die Adressen bekommen.

                          Liste der Adressen steht in der Anleitung zum Zähler

                          z.b.
                          Screenshot_20221005-095825_Polaris Office.jpg

                          bahnuhr 1 Reply Last reply Reply Quote 0
                          • bahnuhr
                            bahnuhr Forum Testing Most Active @Homoran last edited by

                            @homoran sagte in Phasen des Hauses überwachen:

                            Liste der Adressen steht in der Anleitung zum Zähler

                            ja, das weiß ich.
                            Man kann die aber auch rein kopieren und hatte gehofft, dass jemand die Daten zur Verfügung stellt.

                            Die 2. Lösung wäre alles abzutippen.

                            Glasfaser M 2 Replies Last reply Reply Quote 0
                            • Glasfaser
                              Glasfaser @bahnuhr last edited by

                              @bahnuhr sagte in Phasen des Hauses überwachen:

                              @homoran sagte in Phasen des Hauses überwachen:

                              Liste der Adressen steht in der Anleitung zum Zähler

                              ja, das weiß ich.
                              Man kann die aber auch rein kopieren und hatte gehofft, dass jemand die Daten zur Verfügung stellt.

                              Ist das nicht der Zähler , dort ist doch eine Vorlage dazu !?

                              79dd7da2-83a9-4810-9d34-22f56d4e142a-grafik.png

                              https://forum.iobroker.net/post/861590

                              1 Reply Last reply Reply Quote 0
                              • M
                                mane444 @bahnuhr last edited by

                                @bahnuhr Hi Liste hab ich im Post angehängt.
                                Hier nochmal, nur mit einem Zähler Busadresse 1
                                Modbus Register Vorlage.txt

                                1 Reply Last reply Reply Quote 1
                                • First post
                                  Last post

                                Support us

                                ioBroker
                                Community Adapters
                                Donate

                                305
                                Online

                                31.7k
                                Users

                                79.8k
                                Topics

                                1.3m
                                Posts

                                3-phasen
                                7
                                40
                                2035
                                Loading More Posts
                                • Oldest to Newest
                                • Newest to Oldest
                                • Most Votes
                                Reply
                                • Reply as topic
                                Log in to reply
                                Community
                                Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                The ioBroker Community 2014-2023
                                logo