    Datenpunkt aus xml

    This topic has been deleted. Only users with topic management privileges can see it.
    • A
      australien @paul53 last edited by australien

      @paul53
      Unbenannt.JPG

      Homoran 1 Reply Last reply Reply Quote 0
      • Homoran
        Homoran Global Moderator Administrators @australien last edited by

        @australien hst du das modul in der Javascript-Instanz eingetragen?

        A 1 Reply Last reply Reply Quote 0
        • A
          australien @Homoran last edited by australien

          @homoran
          Ja

          Unbenannt.JPG

          Homoran paul53 3 Replies Last reply Reply Quote 0
          • Homoran
            Homoran Global Moderator Administrators @australien last edited by

            @australien sagte in Datenpunkt aus xml:

            @homoran
            Ja

            Unbenannt.JPG

            Nein , nicht da!

            @paul53 sagte in Datenpunkt aus xml:

            @australien sagte in Datenpunkt aus xml:

            xml2js gelesen, aber wo trag ich das ein

            In der JS-Instanz-Konfiguration eintragen:

            JS_NPM.JPG

            da!

            A 1 Reply Last reply Reply Quote 0
            • A
              australien @Homoran last edited by

              @homoran
              auch ja, soweit ich sehe.

              Unbenannt.JPG

              1 Reply Last reply Reply Quote 0
              • paul53
                paul53 @australien last edited by

                @australien
                Siehe Zeile 6: Tausche dp.state.val gegen result aus (hatte ich nach wenigen Sekunden korrigiert).

                1 Reply Last reply Reply Quote 0
                • Homoran
                  Homoran Global Moderator Administrators @australien last edited by Homoran

                  @australien wieso steht bei dir dp in Zeile 13.
                  das ust nicht was Paul schrieb

                  edit: ok, hatte das "original " nicht gesehen

                  1 Reply Last reply Reply Quote 0
                  • A
                    australien last edited by australien

                    jetz kommt Leben ins Geschehen

                    20:19:52.202	info	javascript.0 (6486) Stop script script.js.common.PV
                    20:38:16.280	info	javascript.0 (6486) Stop script script.js.common.PV
                    20:38:17.819	info	javascript.0 (6486) Start javascript script.js.common.PV
                    20:38:17.856	info	javascript.0 (6486) script.js.common.PV: registered 0 subscriptions, 1 schedule, 0 messages, 0 logs and 0 file subscriptions
                    20:39:07.644	info	javascript.0 (6486) script.js.common.PV: {'root':{'Device':[{'$':{'Name':'SF-WR-5503','Type':'Inverter','Serial':'752794AB005565810009','BusAddress':'1','NetBiosName':'INV005565810009','IpAddress':'10.68.0.85','DateTime':'2022-11-14T20:38:18'},'Measurements':[{'Measurement':[{'$':{'Value':'233.046','Unit':'V','Type':'AC_Voltage1'}},{'$':{'Value':'235.306','Unit':'V','Type':'AC_Voltage2'}},{'$':{'Value':'234.911','Unit':'V','Type':'AC_Voltage3'}},{'$':{'Value':'50.002','Unit':'Hz','Type':'AC_Frequency1'}},{'$':{'Value':'50.006','Unit':'Hz','Type':'AC_Frequency2'}},{'$':{'Value':'50.003','Unit':'Hz','Type':'AC_Frequency3'}},{'$':{'Value':'0.000','Unit':'V','Type':'DC_Voltage'}},{'$':{'Value':'21.260','Unit':'°C','Type':'Temp'}}]}]}]}}
                    20:40:00.071	info	javascript.0 (6486) script.js.common.PV: {'root':{'Device':[{'$':{'Name':'SF-WR-5503','Type':'Inverter','Serial':'752794AB005565810009','BusAddress':'1','NetBiosName':'INV005565810009','IpAddress':'10.68.0.85','DateTime':'2022-11-14T20:39:10'},'Measurements':[{'Measurement':[{'$':{'Value':'233.334','Unit':'V','Type':'AC_Voltage1'}},{'$':{'Value':'235.452','Unit':'V','Type':'AC_Voltage2'}},{'$':{'Value':'235.217','Unit':'V','Type':'AC_Voltage3'}},{'$':{'Value':'50.015','Unit':'Hz','Type':'AC_Frequency1'}},{'$':{'Value':'50.024','Unit':'Hz','Type':'AC_Frequency2'}},{'$':{'Value':'50.008','Unit':'Hz','Type':'AC_Frequency3'}},{'$':{'Value':'0.000','Unit':'V','Type':'DC_Voltage'}},{'$':{'Value':'21.250','Unit':'°C','Type':'Temp'}}]}]}]}}
                    
                    

                    nur wir teile ich die Daten nun Datenpunkten zu?

                    paul53 1 Reply Last reply Reply Quote 0
                    • paul53
                      paul53 @australien last edited by paul53

                      @australien sagte in Datenpunkt aus xml:

                      die Daten nun Datenpunkten zu?

                      Ersetze log(obj) durch

                      const messung = obj.root.Device[0].Measurements[0].Measurement;
                      for(let obj of messung) {
                          log(obj.$.Type + ': ' + parseFloat(obj.$.Value) + ' ' + obj.$.Unit);
                          // setState('0_userdata.0.SolarFrontier.' + obj.$.Type, parseFloat(obj.$.Value), true);
                      }
                      

                      Erstelle vorher die 8 Datenpunkte vom Typ "number" unter "0_userdata.0".

                      Log:

                      20:59:41.099	info	javascript.1 (2579) script.js.common.Neuer_Test: AC_Voltage1: 233.046 V
                      20:59:41.100	info	javascript.1 (2579) script.js.common.Neuer_Test: AC_Voltage2: 235.306 V
                      20:59:41.100	info	javascript.1 (2579) script.js.common.Neuer_Test: AC_Voltage3: 234.911 V
                      20:59:41.100	info	javascript.1 (2579) script.js.common.Neuer_Test: AC_Frequency1: 50.002 Hz
                      20:59:41.100	info	javascript.1 (2579) script.js.common.Neuer_Test: AC_Frequency2: 50.006 Hz
                      20:59:41.100	info	javascript.1 (2579) script.js.common.Neuer_Test: AC_Frequency3: 50.003 Hz
                      20:59:41.100	info	javascript.1 (2579) script.js.common.Neuer_Test: DC_Voltage: 0 V
                      20:59:41.100	info	javascript.1 (2579) script.js.common.Neuer_Test: Temp: 21.26 °C
                      
                      Homoran 1 Reply Last reply Reply Quote 0
                      • Homoran
                        Homoran Global Moderator Administrators @paul53 last edited by

                        @paul53 wieso sind im obj nur 8 Werte?
                        die xml enthält 17

                        paul53 1 Reply Last reply Reply Quote 0
                        • paul53
                          paul53 @Homoran last edited by paul53

                          @homoran sagte: die xml enthält 17

                          Dann müssen die übrigen wohl in einem anderen Array-Element enthalten sein. Ich schau mal.

                          Homoran 1 Reply Last reply Reply Quote 0
                          • Homoran
                            Homoran Global Moderator Administrators @paul53 last edited by Homoran

                            @paul53

                            alle in <Measurements>

                            <root>
                            
                            <Device Name="SF-WR-5503" Type="Inverter" Serial="752794Axxxxxxx" BusAddress="1" NetBiosName="INV005565810009" IpAddress="10.68.0.85" DateTime="2022-11-14T14:34:49">
                            
                            <Measurements>
                            
                            <Measurement Value="232.511" Unit="V" Type="AC_Voltage1"/>
                            
                            <Measurement Value="234.392" Unit="V" Type="AC_Voltage2"/>
                            
                            <Measurement Value="234.739" Unit="V" Type="AC_Voltage3"/>
                            
                            <Measurement Value="0.188" Unit="A" Type="AC_Current1"/>
                            
                            <Measurement Value="0.186" Unit="A" Type="AC_Current2"/>
                            
                            <Measurement Value="0.182" Unit="A" Type="AC_Current3"/>
                            
                            <Measurement Value="83.355" Unit="W" Type="AC_Power"/>
                            
                            <Measurement Value="30.510" Unit="W" Type="AC_Power1"/>
                            
                            <Measurement Value="28.707" Unit="W" Type="AC_Power2"/>
                            
                            <Measurement Value="27.966" Unit="W" Type="AC_Power3"/>
                            
                            <Measurement Value="49.997" Unit="Hz" Type="AC_Frequency1"/>
                            
                            <Measurement Value="50.005" Unit="Hz" Type="AC_Frequency2"/>
                            
                            <Measurement Value="50.001" Unit="Hz" Type="AC_Frequency3"/>
                            
                            <Measurement Value="435.600" Unit="V" Type="DC_Voltage"/>
                            
                            <Measurement Value="0.195" Unit="A" Type="DC_Current"/>
                            
                            <Measurement Value="84.942" Unit="W" Type="DC_Power"/>
                            
                            <Measurement Value="39.610" Unit="°C" Type="Temp"/>
                            
                            </Measurements>
                            
                            </Device>
                            
                            </root>
                            
                            
                            paul53 1 Reply Last reply Reply Quote 0
                            • paul53
                              paul53 @Homoran last edited by paul53

                              @homoran
                              Das Ergebnis (Log) von xml2js lieferte nur die 8 Werte.

                              A Homoran 2 Replies Last reply Reply Quote 0
                              • A
                                australien @paul53 last edited by

                                @paul53
                                Unbenannt.JPG

                                super, danke euch beiden!

                                paul53 1 Reply Last reply Reply Quote 0
                                • Homoran
                                  Homoran Global Moderator Administrators @paul53 last edited by

                                  @paul53 das ist ja das Problem
                                  ich habe so etwas auch bei meinem Kostal, allerdings muss ich da in derAPI due gewünschten Parameter abfragen. das ist anscheinend auf eine maximale Anzahl je Abfrage limitiert.
                                  Vielleicht ist die Zeichenanzahl begrenzt

                                  @australien wie bist du denn an das vollständige xml Dokument gekommen?

                                  1 Reply Last reply Reply Quote 0
                                  • paul53
                                    paul53 @australien last edited by

                                    @australien
                                    Kann es sein, dass nachts keine Stromstärke- und Leistungswerte geliefert werden?

                                    Homoran 2 Replies Last reply Reply Quote 1
                                    • Homoran
                                      Homoran Global Moderator Administrators @paul53 last edited by

                                      @paul53 guter Ansatz!

                                      1 Reply Last reply Reply Quote 0
                                      • A
                                        australien last edited by

                                        mit Nachts ist mir klar, ich werd mir das morgen unter Tags noch anschauen, falls kein Nebel ist 😉

                                        Danke Euch beiden nochmals!!

                                        1 Reply Last reply Reply Quote 0
                                        • Homoran
                                          Homoran Global Moderator Administrators @paul53 last edited by

                                          @paul53
                                          @australien
                                          was ist denn die DC Voltage, wenn nicht die Panel Spannung?

                                          und

                                          @homoran sagte in Datenpunkt aus xml:

                                          @australien wie bist du denn an das vollständige xml Dokument gekommen?

                                          1 Reply Last reply Reply Quote 0
                                          • A
                                            australien last edited by

                                            Guten Morgen,
                                            Nebel, aber liefert etwas, somit sind wieder alle 17 Datenpunkte vorhanden.

                                            <Measurements>
                                            <Measurement Value="234.225" Unit="V" Type="AC_Voltage1"/>
                                            <Measurement Value="236.033" Unit="V" Type="AC_Voltage2"/>
                                            <Measurement Value="235.065" Unit="V" Type="AC_Voltage3"/>
                                            <Measurement Value="0.144" Unit="A" Type="AC_Current1"/>
                                            <Measurement Value="0.155" Unit="A" Type="AC_Current2"/>
                                            <Measurement Value="0.147" Unit="A" Type="AC_Current3"/>
                                            <Measurement Value="6.654" Unit="W" Type="AC_Power"/>
                                            <Measurement Value="6.163" Unit="W" Type="AC_Power1"/>
                                            <Measurement Value="2.353" Unit="W" Type="AC_Power2"/>
                                            <Measurement Value="2.135" Unit="W" Type="AC_Power3"/>
                                            <Measurement Value="49.951" Unit="Hz" Type="AC_Frequency1"/>
                                            <Measurement Value="49.957" Unit="Hz" Type="AC_Frequency2"/>
                                            <Measurement Value="49.958" Unit="Hz" Type="AC_Frequency3"/>
                                            <Measurement Value="382.300" Unit="V" Type="DC_Voltage"/>
                                            <Measurement Value="0.017" Unit="A" Type="DC_Current"/>
                                            <Measurement Value="6.499" Unit="W" Type="DC_Power"/>
                                            <Measurement Value="36.550" Unit="°C" Type="Temp"/>
                                            </Measurements>
                                            

                                            @Homoran hatte ich vor 6 Jahren bei der Installation der Anlage erfragt. Es waren sogar 3 xml Seiten, nur die anderen beiden waren nicht brauchbar, weiß die auch nicht mehr.

                                            paul53 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            733
                                            Online

                                            31.8k
                                            Users

                                            80.0k
                                            Topics

                                            1.3m
                                            Posts

                                            4
                                            39
                                            1017
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo