    3. Entwicklung
    4. (GELÖST) zigbee-herdsmann-converters / wie manuell updaten?

    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    (GELÖST) zigbee-herdsmann-converters / wie manuell updaten?

    This topic has been deleted. Only users with topic management privileges can see it.
    • D
      Diamand2k22 @Thomas Braun last edited by Diamand2k22

      @thomas-braun

      habs grad gemerkt, habs oben ausgebessert!
      aber trotzdem noch was schief

      pi4b@pi4b:/opt/iobroker$ npm ls --depth=3 | grep zigbee
      └─┬ iobroker.zigbee@1.7.6 (git+ssh://git@github.com/ioBroker/ioBroker.zigbee.git#84c9eb7accca10de87143e20c4494413a5a16873)
        ├─┬ zigbee-herdsman-converters@14.0.666
        │ └── zigbee-herdsman@0.14.73 deduped
        └─┬ zigbee-herdsman@0.14.73
      npm ERR! code ELSPROBLEMS
      npm ERR! invalid: @types/node@14.18.33 /opt/iobroker/node_modules/iobroker.javascript/node_modules/@types/node
      
      npm ERR! A complete log of this run can be found in:
      npm ERR!     /home/pi4b/.npm/_logs/2022-11-14T22_07_05_771Z-debug-0.log
      
      Thomas Braun 1 Reply Last reply Reply Quote 0
      • Thomas Braun
        Thomas Braun Most Active @Diamand2k22 last edited by

        @diamand2k22

        Kannste überlesen. Ist harmlos, soweit ich das sehe.

        D 1 Reply Last reply Reply Quote 0
        • D
          Diamand2k22 @Thomas Braun last edited by

          @thomas-braun

          sieht in Farbe etwas übler aus.

          121d1aa2-0159-4c1b-a379-cc23bf056bb7-image.png

          aber jetzt passt die version schon mal. 👍

          Thomas Braun 1 Reply Last reply Reply Quote 0
          • Thomas Braun
            Thomas Braun Most Active @Diamand2k22 last edited by Thomas Braun

            @diamand2k22

            Bei

            cd /opt/iobroker && npm ls
            

            kommen keine Fehlermeldungen? Die tieferen Ebenen sind nicht so wichtig, da ist immer etwas Chaos...

            D 1 Reply Last reply Reply Quote 0
            • D
              Diamand2k22 @Thomas Braun last edited by

              @thomas-braun

              bei der Ausgabe kommen keine Fehler!
              Danke dir!

              Thomas Braun 1 Reply Last reply Reply Quote 0
              • Thomas Braun
                Thomas Braun Most Active @Diamand2k22 last edited by

                @diamand2k22

                Und das Gerät ist auch drin?

                D 1 Reply Last reply Reply Quote 0
                • D
                  Diamand2k22 @Thomas Braun last edited by

                  @thomas-braun

                  215e89bf-6ad8-4f3a-af45-7820282d106e-image.png

                  scheint nicht zu klappen 😕

                  Thomas Braun 1 Reply Last reply Reply Quote 0
                  • Thomas Braun
                    Thomas Braun Most Active @Diamand2k22 last edited by

                    @diamand2k22

                    Hier mal geschaut?
                    https://forum.iobroker.net/topic/59852/hama-smartes-heizkörper-thermostat?_=1668467039158

                    D 1 Reply Last reply Reply Quote 0
                    • D
                      Diamand2k22 @Thomas Braun last edited by

                      @thomas-braun

                      Hallo Thomas,

                      hab das mal reinkopiert aber dann startet der zigbee adapter nicht mehr 😕

                      2022-11-15 21:15:17.734 - error: host.pi4b Caught by controller[0]: /opt/iobroker/node_modules/zigbee-herdsman-converters/devices/saswell.js:52
                      2022-11-15 21:15:17.734 - error: host.pi4b Caught by controller[0]: .withAwayMode()],
                      2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: ^
                      2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: TypeError: exposes.climate(...).withSetpoint(...).withLocalTemperature(...).withSystemMode(...).withLocalTemperatureCalibration(...).withAwayMode is not a function
                      2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at Object. (/opt/iobroker/node_modules/zigbee-herdsman-converters/devices/saswell.js:52:18)
                      2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at Module._compile (node:internal/modules/cjs/loader:1155:14)
                      2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at Object.Module._extensions..js (node:internal/modules/cjs/loader:1209:10)
                      2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at Module.load (node:internal/modules/cjs/loader:1033:32)
                      2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at Function.Module._load (node:internal/modules/cjs/loader:868:12)
                      2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at Module.require (node:internal/modules/cjs/loader:1057:19)
                      2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at require (node:internal/modules/cjs/helpers:103:18)
                      2022-11-15 21:15:17.736 - error: host.pi4b Caught by controller[0]: at Object. (/opt/iobroker/node_modules/zigbee-herdsman-converters/index.js:118:30)
                      2022-11-15 21:15:17.736 - error: host.pi4b Caught by controller[0]: at Module._compile (node:internal/modules/cjs/loader:1155:14)
                      2022-11-15 21:15:17.736 - error: host.pi4b Caught by controller[0]: at Object.Module._extensions..js (node:internal/modules/cjs/loader:1209:10)
                      2022-11-15 21:15:17.736 - error: host.pi4b instance system.adapter.zigbee.0 terminated with code 1 (JS_CONTROLLER_STOPPED)
                      
                      Thomas Braun 1 Reply Last reply Reply Quote 0
                      • Thomas Braun
                        Thomas Braun Most Active @Diamand2k22 last edited by

                        @diamand2k22 sagte in (GELÖST) zigbee-herdsmann-converters / wie manuell updaten?:

                        hab das mal reinkopiert

                        Was wo reinkopiert?

                        D 1 Reply Last reply Reply Quote 0
                        • D
                          Diamand2k22 @Thomas Braun last edited by

                          @thomas-braun

                          @david-jung said in Hama Smartes Heizkörper-Thermostat:

                          @david-jung
                          so, ich habe folgendes gemacht:

                          die Datei: /opt/iobroker/node_modules/zigbee-herdsman-converters/devices/saswell.js

                          etwas erweitert, jetzt kann ich die Ist-Temperatur ablesen, so wie die Soll-Temperatur setzen/lesen.
                          Den Modus (heizen/auto/aus) lesen, setzen.
                          Ventil Status ablesen.
                          Und Offset für Temperatur setzen/lesen.

                          /opt/iobroker/node_modules/zigbee-herdsman-converters/devices/saswell.js

                          const exposes = require('../lib/exposes');
                          const fz = {...require('../converters/fromZigbee'), legacy: require('../lib/legacy').fromZigbee};
                          const tz = require('../converters/toZigbee');
                          const tuya = require('../lib/tuya');
                          const reporting = require('../lib/reporting');
                          const e = exposes.presets;
                          const ea = exposes.access;
                          
                          module.exports = [
                              {
                                  fingerprint: [{modelID: 'GbxAXL2\u0000', manufacturerName: '_TYST11_KGbxAXL2'},
                                      {modelID: 'uhszj9s\u0000', manufacturerName: '_TYST11_zuhszj9s'},
                                      {modelID: '88teujp\u0000', manufacturerName: '_TYST11_c88teujp'},
                                      {modelID: 'w7cahqs\u0000', manufacturerName: '_TYST11_yw7cahqs'},
                                      {modelID: 'w7cahqs', manufacturerName: '_TYST11_yw7cahqs'},
                                      {modelID: 'TS0601', manufacturerName: '_TZE200_c88teujp'},
                                      {modelID: 'TS0601', manufacturerName: '_TZE200_yw7cahqs'},
                                      {modelID: 'TS0601', manufacturerName: '_TZE200_azqp6ssj'},
                                      {modelID: 'TS0601', manufacturerName: '_TZE200_bvu2wnxz'},
                                      {modelID: 'TS0601', manufacturerName: '_TZE200_zuhszj9s'},
                                      {modelID: 'TS0601', manufacturerName: '_TZE200_9gvruqf5'},
                                      {modelID: 'TS0601', manufacturerName: '_TZE200_zr9c0day'},
                                  ],
                                  model: 'SEA801-Zigbee/SEA802-Zigbee',
                                  vendor: 'Saswell',
                                  description: 'Thermostatic radiator valve',
                                  whiteLabel: [{vendor: 'HiHome', model: 'WZB-TRVL'}, {vendor: 'Hama', model: '00176592'},
                                      {vendor: 'RTX', model: 'ZB-RT1'}],
                                  fromZigbee: [fz.saswell_thermostat, fz.ignore_tuya_set_time, fz.ignore_basic_report, fz.legacy.tuya_thermostat_weekly_schedule],
                                  toZigbee: [tz.saswell_thermostat_current_heating_setpoint, tz.saswell_thermostat_mode, tz.saswell_thermostat_away,
                                      tz.saswell_thermostat_child_lock, tz.saswell_thermostat_window_detection, tz.saswell_thermostat_frost_detection,
                                      tz.saswell_thermostat_calibration, tz.saswell_thermostat_anti_scaling, tz.tuya_thermostat_weekly_schedule],
                                  onEvent: tuya.onEventSetTime,
                                  meta: {
                                      thermostat: {
                                          weeklyScheduleMaxTransitions: 4,
                                          weeklyScheduleSupportedModes: [1], // bits: 0-heat present, 1-cool present (dec: 1-heat,2-cool,3-heat+cool)
                                          weeklyScheduleConversion: 'saswell',
                                      },
                                  },
                                  configure: async (device, coordinatorEndpoint, logger) => {
                                      const endpoint = device.getEndpoint(1);
                                      await reporting.bind(endpoint, coordinatorEndpoint, ['genBasic']);
                                  },
                                  exposes: [e.battery_low(), e.window_detection(), e.child_lock(),
                                      exposes.binary('heating', ea.STATE, 'ON', 'OFF').withDescription('Device valve is open or closed (heating or not)'),
                                      exposes.climate()
                                          .withSetpoint('current_heating_setpoint', 5, 30, 0.5, ea.STATE_SET).withLocalTemperature(ea.STATE)
                                          .withSystemMode(['off', 'heat', 'auto'], ea.STATE_SET)
                                          // Range is -6 - 6 and step 1: https://github.com/Koenkk/zigbee2mqtt/issues/11777
                                          .withLocalTemperatureCalibration(-6, 6, 1, ea.STATE_SET)
                                          .withAwayMode()],
                              },
                          	{
                          		/*added by djung 10.11.2022*/
                          	fingerprint: [{modelID: 'TS0601', manufacturerName: '_TZE200_h4cgnbzg'}],
                                  model: 'HZ',
                                  vendor: 'HAMA',
                                  description: 'Thermostatic radiator valve',
                                  whiteLabel: [{vendor: 'Hama', model: 'XXXxxxXXX'},],
                                  fromZigbee: [fz.saswell_thermostat],
                                  toZigbee: [tz.saswell_thermostat_current_heating_setpoint, tz.saswell_thermostat_mode, 
                                      tz.saswell_thermostat_calibration],
                                  onEvent: tuya.onEventSetTime,
                                  configure: async (device, coordinatorEndpoint, logger) => {
                                      const endpoint = device.getEndpoint(1);
                                      await reporting.bind(endpoint, coordinatorEndpoint, ['genBasic']);
                                  },
                                  exposes: [
                          			e.battery_low(),
                          			/*e.switch(),*/
                          			/*e.lock(),*/
                          			exposes.binary('heating', ea.STATE, 'ON', 'OFF').withDescription('Device valve is open or closed (heating or not)'),
                          		
                                      exposes.climate()
                                          .withSetpoint('current_heating_setpoint', 5, 30, 0.5, ea.STATE_SET).withLocalTemperature(ea.STATE)
                                          .withSystemMode(['off', 'heat', 'auto'], ea.STATE_SET)
                                          // Range is -6 - 6 and step 1: https://github.com/Koenkk/zigbee2mqtt/issues/11777
                                          .withLocalTemperatureCalibration(-6, 6, 1, ea.STATE_SET)
                                          ],
                              },
                          ];
                          

                          soll man das irgendwo auf github oder so noch posten? Wenn ja, bitte zeigen wo 😃
                          Grüße.
                          David.

                          Thomas Braun 1 Reply Last reply Reply Quote 0
                          • Thomas Braun
                            Thomas Braun Most Active @Diamand2k22 last edited by

                            @diamand2k22

                            Alles? Das war nur als Denkansatz für dich gedacht.
                            Ich hätte da erstmal nur die Manufacturer-ID hinzugefügt. Sind ja schon ein paar Varianten von dem Thermostat mit der Modellbezeichnung TS0601 vorhanden.

                            D 1 Reply Last reply Reply Quote 0
                            • D
                              Diamand2k22 @Thomas Braun last edited by

                              @thomas-braun

                              hab die manufactor id eingefügt, jetzt erkennt er das thermostat, liefert aber keine werte!

                              2022-11-15 21:35:02.182 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #2 with data {"dp":2,"datatype":4,"data":{"type":"Buffer","data":[2]}}
                              2022-11-15 21:35:02.434 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #4 with data {"dp":4,"datatype":2,"data":{"type":"Buffer","data":[0,0,0,50]}}
                              2022-11-15 21:35:02.551 - info: dwd.0 (92835) starting. Version 2.8.3 in /opt/iobroker/node_modules/iobroker.dwd, node: v16.18.1, js-controller: 4.0.23
                              2022-11-15 21:35:02.555 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #5 with data {"dp":5,"datatype":2,"data":{"type":"Buffer","data":[0,0,0,200]}}
                              2022-11-15 21:35:02.704 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #7 with data {"dp":7,"datatype":1,"data":{"type":"Buffer","data":[0]}}
                              2022-11-15 21:35:02.789 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #28 with data {"dp":28,"datatype":0,"data":{"type":"Buffer","data":[1,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                              2022-11-15 21:35:02.906 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #29 with data {"dp":29,"datatype":0,"data":{"type":"Buffer","data":[2,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                              2022-11-15 21:35:03.032 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #30 with data {"dp":30,"datatype":0,"data":{"type":"Buffer","data":[3,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                              2022-11-15 21:35:03.144 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #31 with data {"dp":31,"datatype":0,"data":{"type":"Buffer","data":[4,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                              2022-11-15 21:35:03.264 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #32 with data {"dp":32,"datatype":0,"data":{"type":"Buffer","data":[5,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                              2022-11-15 21:35:03.380 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #33 with data {"dp":33,"datatype":0,"data":{"type":"Buffer","data":[6,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                              2022-11-15 21:35:03.502 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #34 with data {"dp":34,"datatype":0,"data":{"type":"Buffer","data":[7,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                              2022-11-15 21:35:03.615 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #35 with data {"dp":35,"datatype":5,"data":{"type":"Buffer","data":[0]}}
                              2022-11-15 21:35:03.731 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #36 with data {"dp":36,"datatype":1,"data":{"type":"Buffer","data":[0]}}
                              2022-11-15 21:35:03.848 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #39 with data {"dp":39,"datatype":1,"data":{"type":"Buffer","data":[0]}}
                              2022-11-15 21:35:03.968 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #47 with data {"dp":47,"datatype":2,"data":{"type":"Buffer","data":[0,0,0,0]}}
                              

                              631ff6c6-6764-46c7-a7ab-3cfe0302bbb8-image.png

                              Thomas Braun 1 Reply Last reply Reply Quote 0
                              • Thomas Braun
                                Thomas Braun Most Active @Diamand2k22 last edited by Thomas Braun

                                @diamand2k22

                                Ich kann dir da nicht weiterhelfen.
                                Vielleicht weiß @david-jung ja noch was dazu.

                                1 Reply Last reply Reply Quote 0
                                • D
                                  Diamand2k22 last edited by

                                  @thomas-braun

                                  kann es sein, dass mit den Rechten was nicht stimmt?`

                                  $ iobroker url ioBroker/ioBroker.zigbee --host pi4b --debug
                                  
                                  install ioBroker/ioBroker.zigbee
                                  
                                  NPM version: 8.19.2
                                  
                                  Installing ioBroker/ioBroker.zigbee... (System call)
                                  
                                  npm WARN cleanup Failed to remove some directories [npm WARN cleanup [
                                  
                                  npm WARN cleanup '/opt/iobroker/node_modules/.zigbee-herdsman-converters-DzgWyYTV',npm WARN cleanup [Error: EACCES: permission denied, scandir '/opt/iobroker/node_modules/.zigbee-herdsman-converters-DzgWyYTV/devices'] {npm WARN cleanup errno: -13,npm WARN cleanup code: 'EACCES',npm WARN cleanup syscall: 'scandir',npm WARN cleanup path: '/opt/iobroker/node_modules/.zigbee-herdsman-converters-DzgWyYTV/devices'npm WARN cleanup }npm WARN cleanup ]npm WARN cleanup 
                                  
                                  Thomas Braun 1 Reply Last reply Reply Quote 0
                                  • Thomas Braun
                                    Thomas Braun Most Active @Diamand2k22 last edited by

                                    @diamand2k22 sagte in (GELÖST) zigbee-herdsmann-converters / wie manuell updaten?:

                                    dass mit den Rechten was nicht stimmt?`

                                    iob stop
                                    iob fix
                                    iob start
                                    
                                    D 1 Reply Last reply Reply Quote 0
                                    • D
                                      Diamand2k22 @Thomas Braun last edited by

                                      @thomas-braun

                                      danke dir für die schnelle Rückmeldung.
                                      Hab's dann doch selber hinbekommen!

                                      Gruß

                                      DJMarc75 1 Reply Last reply Reply Quote 0
                                      • DJMarc75
                                        DJMarc75 @Diamand2k22 last edited by

                                        @diamand2k22 sagte in (GELÖST) zigbee-herdsmann-converters / wie manuell updaten?:

                                        Hab's dann doch selber hinbekommen!

                                        Und des Rätsels Lösung war ?
                                        Vll hilft das auch anderen Mitlesenden !

                                        D 1 Reply Last reply Reply Quote 0
                                        • D
                                          Diamand2k22 @DJMarc75 last edited by

                                          @djmarc75

                                          hat Thomas schon geschrieben.

                                          iob stop
                                          iob fix
                                          iob start
                                          

                                          Gruß

                                          Thomas Braun 1 Reply Last reply Reply Quote 0
                                          • Thomas Braun
                                            Thomas Braun Most Active @Diamand2k22 last edited by

                                            @diamand2k22

                                            Dann hast du da mal mit falschen Rechten hantiert.
                                            root login?

                                            P 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            293
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            herdsman zigbee
                                            13
                                            129
                                            16324
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo