Navigation

    Logo
    • Register
    • Login
    • Search
    • Recent
    • Tags
    • Unread
    • Categories
    • Unreplied
    • Popular
    • GitHub
    • Docu
    • Hilfe
    1. Home
    2. Deutsch
    3. Entwicklung
    4. (GELÖST) zigbee-herdsmann-converters / wie manuell updaten?

    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    (GELÖST) zigbee-herdsmann-converters / wie manuell updaten?

    This topic has been deleted. Only users with topic management privileges can see it.
    • Thomas Braun
      Thomas Braun Most Active @Diamand2k22 last edited by

      @diamand2k22

      Hier mal geschaut?
      https://forum.iobroker.net/topic/59852/hama-smartes-heizkörper-thermostat?_=1668467039158

      D 1 Reply Last reply Reply Quote 0
      • D
        Diamand2k22 @Thomas Braun last edited by

        @thomas-braun

        Hallo Thomas,

        hab das mal reinkopiert aber dann startet der zigbee adapter nicht mehr 😕

        2022-11-15 21:15:17.734 - error: host.pi4b Caught by controller[0]: /opt/iobroker/node_modules/zigbee-herdsman-converters/devices/saswell.js:52
        2022-11-15 21:15:17.734 - error: host.pi4b Caught by controller[0]: .withAwayMode()],
        2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: ^
        2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: TypeError: exposes.climate(...).withSetpoint(...).withLocalTemperature(...).withSystemMode(...).withLocalTemperatureCalibration(...).withAwayMode is not a function
        2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at Object. (/opt/iobroker/node_modules/zigbee-herdsman-converters/devices/saswell.js:52:18)
        2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at Module._compile (node:internal/modules/cjs/loader:1155:14)
        2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at Object.Module._extensions..js (node:internal/modules/cjs/loader:1209:10)
        2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at Module.load (node:internal/modules/cjs/loader:1033:32)
        2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at Function.Module._load (node:internal/modules/cjs/loader:868:12)
        2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at Module.require (node:internal/modules/cjs/loader:1057:19)
        2022-11-15 21:15:17.735 - error: host.pi4b Caught by controller[0]: at require (node:internal/modules/cjs/helpers:103:18)
        2022-11-15 21:15:17.736 - error: host.pi4b Caught by controller[0]: at Object. (/opt/iobroker/node_modules/zigbee-herdsman-converters/index.js:118:30)
        2022-11-15 21:15:17.736 - error: host.pi4b Caught by controller[0]: at Module._compile (node:internal/modules/cjs/loader:1155:14)
        2022-11-15 21:15:17.736 - error: host.pi4b Caught by controller[0]: at Object.Module._extensions..js (node:internal/modules/cjs/loader:1209:10)
        2022-11-15 21:15:17.736 - error: host.pi4b instance system.adapter.zigbee.0 terminated with code 1 (JS_CONTROLLER_STOPPED)
        
        Thomas Braun 1 Reply Last reply Reply Quote 0
        • Thomas Braun
          Thomas Braun Most Active @Diamand2k22 last edited by

          @diamand2k22 sagte in (GELÖST) zigbee-herdsmann-converters / wie manuell updaten?:

          hab das mal reinkopiert

          Was wo reinkopiert?

          D 1 Reply Last reply Reply Quote 0
          • D
            Diamand2k22 @Thomas Braun last edited by

            @thomas-braun

            @david-jung said in Hama Smartes Heizkörper-Thermostat:

            @david-jung
            so, ich habe folgendes gemacht:

            die Datei: /opt/iobroker/node_modules/zigbee-herdsman-converters/devices/saswell.js

            etwas erweitert, jetzt kann ich die Ist-Temperatur ablesen, so wie die Soll-Temperatur setzen/lesen.
            Den Modus (heizen/auto/aus) lesen, setzen.
            Ventil Status ablesen.
            Und Offset für Temperatur setzen/lesen.

            /opt/iobroker/node_modules/zigbee-herdsman-converters/devices/saswell.js

            const exposes = require('../lib/exposes');
            const fz = {...require('../converters/fromZigbee'), legacy: require('../lib/legacy').fromZigbee};
            const tz = require('../converters/toZigbee');
            const tuya = require('../lib/tuya');
            const reporting = require('../lib/reporting');
            const e = exposes.presets;
            const ea = exposes.access;
            
            module.exports = [
                {
                    fingerprint: [{modelID: 'GbxAXL2\u0000', manufacturerName: '_TYST11_KGbxAXL2'},
                        {modelID: 'uhszj9s\u0000', manufacturerName: '_TYST11_zuhszj9s'},
                        {modelID: '88teujp\u0000', manufacturerName: '_TYST11_c88teujp'},
                        {modelID: 'w7cahqs\u0000', manufacturerName: '_TYST11_yw7cahqs'},
                        {modelID: 'w7cahqs', manufacturerName: '_TYST11_yw7cahqs'},
                        {modelID: 'TS0601', manufacturerName: '_TZE200_c88teujp'},
                        {modelID: 'TS0601', manufacturerName: '_TZE200_yw7cahqs'},
                        {modelID: 'TS0601', manufacturerName: '_TZE200_azqp6ssj'},
                        {modelID: 'TS0601', manufacturerName: '_TZE200_bvu2wnxz'},
                        {modelID: 'TS0601', manufacturerName: '_TZE200_zuhszj9s'},
                        {modelID: 'TS0601', manufacturerName: '_TZE200_9gvruqf5'},
                        {modelID: 'TS0601', manufacturerName: '_TZE200_zr9c0day'},
                    ],
                    model: 'SEA801-Zigbee/SEA802-Zigbee',
                    vendor: 'Saswell',
                    description: 'Thermostatic radiator valve',
                    whiteLabel: [{vendor: 'HiHome', model: 'WZB-TRVL'}, {vendor: 'Hama', model: '00176592'},
                        {vendor: 'RTX', model: 'ZB-RT1'}],
                    fromZigbee: [fz.saswell_thermostat, fz.ignore_tuya_set_time, fz.ignore_basic_report, fz.legacy.tuya_thermostat_weekly_schedule],
                    toZigbee: [tz.saswell_thermostat_current_heating_setpoint, tz.saswell_thermostat_mode, tz.saswell_thermostat_away,
                        tz.saswell_thermostat_child_lock, tz.saswell_thermostat_window_detection, tz.saswell_thermostat_frost_detection,
                        tz.saswell_thermostat_calibration, tz.saswell_thermostat_anti_scaling, tz.tuya_thermostat_weekly_schedule],
                    onEvent: tuya.onEventSetTime,
                    meta: {
                        thermostat: {
                            weeklyScheduleMaxTransitions: 4,
                            weeklyScheduleSupportedModes: [1], // bits: 0-heat present, 1-cool present (dec: 1-heat,2-cool,3-heat+cool)
                            weeklyScheduleConversion: 'saswell',
                        },
                    },
                    configure: async (device, coordinatorEndpoint, logger) => {
                        const endpoint = device.getEndpoint(1);
                        await reporting.bind(endpoint, coordinatorEndpoint, ['genBasic']);
                    },
                    exposes: [e.battery_low(), e.window_detection(), e.child_lock(),
                        exposes.binary('heating', ea.STATE, 'ON', 'OFF').withDescription('Device valve is open or closed (heating or not)'),
                        exposes.climate()
                            .withSetpoint('current_heating_setpoint', 5, 30, 0.5, ea.STATE_SET).withLocalTemperature(ea.STATE)
                            .withSystemMode(['off', 'heat', 'auto'], ea.STATE_SET)
                            // Range is -6 - 6 and step 1: https://github.com/Koenkk/zigbee2mqtt/issues/11777
                            .withLocalTemperatureCalibration(-6, 6, 1, ea.STATE_SET)
                            .withAwayMode()],
                },
            	{
            		/*added by djung 10.11.2022*/
            	fingerprint: [{modelID: 'TS0601', manufacturerName: '_TZE200_h4cgnbzg'}],
                    model: 'HZ',
                    vendor: 'HAMA',
                    description: 'Thermostatic radiator valve',
                    whiteLabel: [{vendor: 'Hama', model: 'XXXxxxXXX'},],
                    fromZigbee: [fz.saswell_thermostat],
                    toZigbee: [tz.saswell_thermostat_current_heating_setpoint, tz.saswell_thermostat_mode, 
                        tz.saswell_thermostat_calibration],
                    onEvent: tuya.onEventSetTime,
                    configure: async (device, coordinatorEndpoint, logger) => {
                        const endpoint = device.getEndpoint(1);
                        await reporting.bind(endpoint, coordinatorEndpoint, ['genBasic']);
                    },
                    exposes: [
            			e.battery_low(),
            			/*e.switch(),*/
            			/*e.lock(),*/
            			exposes.binary('heating', ea.STATE, 'ON', 'OFF').withDescription('Device valve is open or closed (heating or not)'),
            		
                        exposes.climate()
                            .withSetpoint('current_heating_setpoint', 5, 30, 0.5, ea.STATE_SET).withLocalTemperature(ea.STATE)
                            .withSystemMode(['off', 'heat', 'auto'], ea.STATE_SET)
                            // Range is -6 - 6 and step 1: https://github.com/Koenkk/zigbee2mqtt/issues/11777
                            .withLocalTemperatureCalibration(-6, 6, 1, ea.STATE_SET)
                            ],
                },
            ];
            

            soll man das irgendwo auf github oder so noch posten? Wenn ja, bitte zeigen wo 😃
            Grüße.
            David.

            Thomas Braun 1 Reply Last reply Reply Quote 0
            • Thomas Braun
              Thomas Braun Most Active @Diamand2k22 last edited by

              @diamand2k22

              Alles? Das war nur als Denkansatz für dich gedacht.
              Ich hätte da erstmal nur die Manufacturer-ID hinzugefügt. Sind ja schon ein paar Varianten von dem Thermostat mit der Modellbezeichnung TS0601 vorhanden.

              D 1 Reply Last reply Reply Quote 0
              • D
                Diamand2k22 @Thomas Braun last edited by

                @thomas-braun

                hab die manufactor id eingefügt, jetzt erkennt er das thermostat, liefert aber keine werte!

                2022-11-15 21:35:02.182 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #2 with data {"dp":2,"datatype":4,"data":{"type":"Buffer","data":[2]}}
                2022-11-15 21:35:02.434 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #4 with data {"dp":4,"datatype":2,"data":{"type":"Buffer","data":[0,0,0,50]}}
                2022-11-15 21:35:02.551 - info: dwd.0 (92835) starting. Version 2.8.3 in /opt/iobroker/node_modules/iobroker.dwd, node: v16.18.1, js-controller: 4.0.23
                2022-11-15 21:35:02.555 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #5 with data {"dp":5,"datatype":2,"data":{"type":"Buffer","data":[0,0,0,200]}}
                2022-11-15 21:35:02.704 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #7 with data {"dp":7,"datatype":1,"data":{"type":"Buffer","data":[0]}}
                2022-11-15 21:35:02.789 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #28 with data {"dp":28,"datatype":0,"data":{"type":"Buffer","data":[1,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                2022-11-15 21:35:02.906 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #29 with data {"dp":29,"datatype":0,"data":{"type":"Buffer","data":[2,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                2022-11-15 21:35:03.032 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #30 with data {"dp":30,"datatype":0,"data":{"type":"Buffer","data":[3,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                2022-11-15 21:35:03.144 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #31 with data {"dp":31,"datatype":0,"data":{"type":"Buffer","data":[4,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                2022-11-15 21:35:03.264 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #32 with data {"dp":32,"datatype":0,"data":{"type":"Buffer","data":[5,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                2022-11-15 21:35:03.380 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #33 with data {"dp":33,"datatype":0,"data":{"type":"Buffer","data":[6,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                2022-11-15 21:35:03.502 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #34 with data {"dp":34,"datatype":0,"data":{"type":"Buffer","data":[7,6,0,0,120,8,0,0,160,18,0,0,220,20,0,0,200]}}
                2022-11-15 21:35:03.615 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #35 with data {"dp":35,"datatype":5,"data":{"type":"Buffer","data":[0]}}
                2022-11-15 21:35:03.731 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #36 with data {"dp":36,"datatype":1,"data":{"type":"Buffer","data":[0]}}
                2022-11-15 21:35:03.848 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #39 with data {"dp":39,"datatype":1,"data":{"type":"Buffer","data":[0]}}
                2022-11-15 21:35:03.968 - warn: zigbee.0 (92569) zigbee-herdsman-converters:SaswellThermostat: Unrecognized DP #47 with data {"dp":47,"datatype":2,"data":{"type":"Buffer","data":[0,0,0,0]}}
                

                631ff6c6-6764-46c7-a7ab-3cfe0302bbb8-image.png

                Thomas Braun 1 Reply Last reply Reply Quote 0
                • Thomas Braun
                  Thomas Braun Most Active @Diamand2k22 last edited by Thomas Braun

                  @diamand2k22

                  Ich kann dir da nicht weiterhelfen.
                  Vielleicht weiß @david-jung ja noch was dazu.

                  1 Reply Last reply Reply Quote 0
                  • D
                    Diamand2k22 last edited by

                    @thomas-braun

                    kann es sein, dass mit den Rechten was nicht stimmt?`

                    $ iobroker url ioBroker/ioBroker.zigbee --host pi4b --debug
                    
                    install ioBroker/ioBroker.zigbee
                    
                    NPM version: 8.19.2
                    
                    Installing ioBroker/ioBroker.zigbee... (System call)
                    
                    npm WARN cleanup Failed to remove some directories [npm WARN cleanup [
                    
                    npm WARN cleanup '/opt/iobroker/node_modules/.zigbee-herdsman-converters-DzgWyYTV',npm WARN cleanup [Error: EACCES: permission denied, scandir '/opt/iobroker/node_modules/.zigbee-herdsman-converters-DzgWyYTV/devices'] {npm WARN cleanup errno: -13,npm WARN cleanup code: 'EACCES',npm WARN cleanup syscall: 'scandir',npm WARN cleanup path: '/opt/iobroker/node_modules/.zigbee-herdsman-converters-DzgWyYTV/devices'npm WARN cleanup }npm WARN cleanup ]npm WARN cleanup 
                    
                    Thomas Braun 1 Reply Last reply Reply Quote 0
                    • Thomas Braun
                      Thomas Braun Most Active @Diamand2k22 last edited by

                      @diamand2k22 sagte in (GELÖST) zigbee-herdsmann-converters / wie manuell updaten?:

                      dass mit den Rechten was nicht stimmt?`

                      iob stop
                      iob fix
                      iob start
                      
                      D 1 Reply Last reply Reply Quote 0
                      • D
                        Diamand2k22 @Thomas Braun last edited by

                        @thomas-braun

                        danke dir für die schnelle Rückmeldung.
                        Hab's dann doch selber hinbekommen!

                        Gruß

                        DJMarc75 1 Reply Last reply Reply Quote 0
                        • DJMarc75
                          DJMarc75 @Diamand2k22 last edited by

                          @diamand2k22 sagte in (GELÖST) zigbee-herdsmann-converters / wie manuell updaten?:

                          Hab's dann doch selber hinbekommen!

                          Und des Rätsels Lösung war ?
                          Vll hilft das auch anderen Mitlesenden !

                          D 1 Reply Last reply Reply Quote 0
                          • D
                            Diamand2k22 @DJMarc75 last edited by

                            @djmarc75

                            hat Thomas schon geschrieben.

                            iob stop
                            iob fix
                            iob start
                            

                            Gruß

                            Thomas Braun 1 Reply Last reply Reply Quote 0
                            • Thomas Braun
                              Thomas Braun Most Active @Diamand2k22 last edited by

                              @diamand2k22

                              Dann hast du da mal mit falschen Rechten hantiert.
                              root login?

                              P 1 Reply Last reply Reply Quote 0
                              • D
                                Diamand2k22 last edited by Diamand2k22

                                @thomas-braun

                                kann sein Thomas, hab ich aber wieder hingebogen bekommen.

                                @Asgothian
                                hab mir jetzt ne eigene ketotek.js für mein Heizkörperthermostat gebastelt.
                                Jetzt funktioniert es wunderbar und ich hab keine Unrecognized DP's mehr und kann es steuern und empfange Temperaturen.
                                Was mich nur interessieren würde, wie bekomme ich da ein vernünftiges Bild rein?
                                Kannst du das Thermostat aufnehmen?

                                35435839-22f6-4619-b144-caf46564bd54-image.png

                                207436ce-52d0-4f3d-9461-be1c73952317-image.png

                                017cd8ca-653c-426c-b51c-54584e40d73c-image.png

                                252632ff-147e-4494-904e-d3209eae375a-image.png

                                550af260-fee3-420e-a6e0-140cdba890df-image.png

                                Gruß

                                D 1 Reply Last reply Reply Quote 0
                                • P
                                  Patrick Kenzler @Thomas Braun last edited by

                                  @thomas-braun könntest du deinen externen Konverter zur Verfügung stellen? Sitze schon seit Tagen und komme nicht weiter.

                                  Thomas Braun 1 Reply Last reply Reply Quote 0
                                  • Thomas Braun
                                    Thomas Braun Most Active @Patrick Kenzler last edited by

                                    @patrick-kenzler

                                    Meinen was? Wüsste nicht das ich sowas im Einsatz hätte.

                                    P 1 Reply Last reply Reply Quote 0
                                    • P
                                      Patrick Kenzler @Thomas Braun last edited by

                                      @thomas-braun sorry, die Frage sollte eigentlich an @Diamand2k22 gehen habe mich verklickt^^

                                      D 1 Reply Last reply Reply Quote 0
                                      • D
                                        Diamand2k22 @Patrick Kenzler last edited by

                                        @patrick-kenzler

                                        Hast du auch so ein ketotek Teil von Amaz**?

                                        P 1 Reply Last reply Reply Quote 0
                                        • P
                                          Patrick Kenzler @Diamand2k22 last edited by

                                          @diamand2k22 said in (GELÖST) zigbee-herdsmann-converters / wie manuell updaten?:

                                          @patrick-kenzler

                                          Hast du auch so ein ketotek Teil von Amaz**?

                                          nein, aber Avatto ME167 das wird auch unter _TZE200_bvu2wnxz geführt.

                                          1 Reply Last reply Reply Quote 0
                                          • D
                                            Diamand2k22 last edited by

                                            @patrick-kenzler

                                            06b9e9de-716c-4a03-95a1-94f34a45ccf6-avatto_me167.js

                                            Hab's angepasst für dein ME167 Thermostat.
                                            Probiers mal aus.

                                            Du weißt ja wo die Datei hin muss oder?

                                            P 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            788
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            herdsman zigbee
                                            13
                                            129
                                            16348
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo