Navigation

    Logo
    • Register
    • Login
    • Search
    • Recent
    • Tags
    • Unread
    • Categories
    • Unreplied
    • Popular
    • GitHub
    • Docu
    • Hilfe
    1. Home
    2. Deutsch
    3. Tester
    4. Alpha Testing: OCPP Wallbox Adapter

    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    Alpha Testing: OCPP Wallbox Adapter

    This topic has been deleted. Only users with topic management privileges can see it.
    • foxriver76
      foxriver76 Developer @Meister Mopper last edited by

      @meister-mopper So einen Start benötige ich auf debug wie

      ocpp.0	2022-09-20 15:43:54.143	debug	Sending RemoteStartTransaction for http://192_168_178_80:9220/EVB-XXXXXXXXX: {"connectorId":1,"idTag":"XXXXXXXXX"}
      

      Die Zeile nur wenn es fehlschlägt, sprich Adapter auf Loglevel Debug stellen und dann eine Transaktion starten. Was ja nicht gehen sollte.

      Meister Mopper 1 Reply Last reply Reply Quote 0
      • Meister Mopper
        Meister Mopper @foxriver76 last edited by

        @foxriver76

        Ich habe die Instanz so eingestellt:

        205bff3c-9ebc-4c7f-ae20-d902bf8e9b08-grafik.png

        Es kommt aber nicht mehr als:

        ocpp.0	2022-09-20 16:30:53.680	error	Cannot execute command "transactionActive" for "http://192_168_178_80:9220/EVB-XXXXXXXXX": Sender's message does not comply with protocol specification.
        

        Woran liegt das?

        foxriver76 1 Reply Last reply Reply Quote 0
        • foxriver76
          foxriver76 Developer @Meister Mopper last edited by foxriver76

          @meister-mopper hm komisch, da sollte auf jeden fall ein debug log kommen.

          Kannst du mal bitte auf 0.7.0 updaten, es sollte ein State erstellt werden chargeLimitType da solltest du zwischen A und W wählen können. Bitte mal prüfen, dass bei Änderung sich die Einheit vom chargeLimit State ändert.

          Falls das tut mal z. B. auf W stellen und 8000 in den chargeLimit State schreiben und dann nochmal transactionActive triggern. Und bitte alles auf debug nach Möglichkeit.

          Meister Mopper 1 Reply Last reply Reply Quote 0
          • Meister Mopper
            Meister Mopper @foxriver76 last edited by Meister Mopper

            @foxriver76

            Update auf 0.7.0:

            $ iobroker url https://github.com/foxriver76/ioBroker.ocpp.git --host rpizigbee --debug
            install foxriver76/ioBroker.ocpp#a7c06c513c0e8c6272a10deddd07152bc6efbed7
            NPM version: 8.15.0
            Installing foxriver76/ioBroker.ocpp#a7c06c513c0e8c6272a10deddd07152bc6efbed7... (System call)
            npm WARN skipping integrity check for git dependency ssh://git@github.com/foxriver76/ioBroker.ocpp.git
            npm WARN deprecated joi-date-extensions@1.2.0: This module has moved and is now available at @hapi/joi-date. Please update your dependencies as this version is no longer maintained an may contain bugs and security issues.
            npm WARN deprecated hoek@5.0.4: This version has been deprecated in accordance with the hapi support policy (hapi.im/support). Please upgrade to the latest version to get the best features, bug fixes, and security patches. If you are unable to upgrade at this time, paid support is available for older versions (hapi.im/commercial).
            npm WARN deprecated hoek@6.1.3: This module has moved and is now available at @hapi/hoek. Please update your dependencies as this version is no longer maintained an may contain bugs and security issues.
            npm WARN deprecated joi@13.7.0: This version has been deprecated in accordance with the hapi support policy (hapi.im/support). Please upgrade to the latest version to get the best features, bug fixes, and security patches. If you are unable to upgrade at this time, paid support is available for older versions (hapi.im/commercial).
            added 8 packages, and changed 51 packages in 2m88 packages are looking for funding run `npm fund` for details
            upload [1] ocpp.admin /opt/iobroker/node_modules/iobroker.ocpp/admin/jsonConfig.json jsonConfig.json application/json
            upload [0] ocpp.admin /opt/iobroker/node_modules/iobroker.ocpp/admin/ocpp.png ocpp.png image/png
            Update "system.adapter.ocpp.0"
            Process exited with code 0
            

            Ich kann auf Watt umstellen, die Einheit ändert sich auch. Allerdings beginnt der Ladevorgang nach transactionActive nicht und ich musste mit dem rfid chip direkt an der Wallbox das Laden starten.
            00f9dfec-ebff-4192-b22d-bef32259cf48-grafik.png

            Hier Energy_Active_Import_Register
            ffa7ce40-55d1-44ee-b0ec-5028ee474167-grafik.png

            So sieht es dann aus (das Haus benötigt ca. 500 W):

            Verbrauch.gif

            Hier noch das log:

            ocpp.0	2022-09-21 15:26:58.566	info	New valid connection from "http://192.168.178.80:9220/EVB-XXXXXXXXX" (http/ocpp1.6)
            ocpp.0	2022-09-21 15:41:35.643	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": Preparing
            ocpp.0	2022-09-21 15:41:35.727	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,Preparing,NoError,No error.,0,Green,0,{20,7984,100},{0,0},{B,11940,10012,61568},0,0,300,2022-09-21T13:41:35Z,0,3,{0,0,0,0,0,0,0,0,0},220,1,1,112,0,230,900,0
            ocpp.0	2022-09-21 15:41:42.522	info	Received Authorization Request from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 15:41:44.670	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": Preparing
            ocpp.0	2022-09-21 15:41:44.716	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,Preparing,NoError,No error.,0,Off,1,{20,7984,100},{0,0},{B,11936,9146,61568},0,0,300,2022-09-21T13:41:44Z,0,3,{0,0,0,0,0,0,0,0,0},220,0,0,125,0,230,900,0
            ocpp.0	2022-09-21 15:41:46.974	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": SuspendedEVSE
            ocpp.0	2022-09-21 15:41:47.178	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": SuspendedEV
            ocpp.0	2022-09-21 15:41:49.463	info	Received Start transaction from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 15:41:50.480	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": Charging
            ocpp.0	2022-09-21 15:41:54.388	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,SuspendedEVSE,NoError,No error.,0,Yellow,1,{20,7984,10},{0,0},{B,11937,8736,9416},0,0,300,2022-09-21T13:41:46Z,1,3,{0,0,0,0,0,0,0,0,0},220,0,0,125,0,230,60,0
            ocpp.0	2022-09-21 15:41:59.374	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,SuspendedEV,NoError,No error.,0,Yellow,1,{20,7984,10},{0,0},{B,11938,8652,12128},0,0,300,2022-09-21T13:41:46Z,1,3,{0,0,0,0,0,0,0,0,0},220,0,0,125,0,230,60,0
            ocpp.0	2022-09-21 15:42:04.372	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,Charging,NoError,No error.,1,Blue,1,{20,7984,26},{0,0},{C,11936,5868,12131},0,0,300,2022-09-21T13:41:50Z,1,3,{0,0,0,0,0,0,0,0,0},220,2,0,114,0,230,160,0
            ocpp.0	2022-09-21 15:56:51.319	info	Received MeterValues from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 15:56:56.363	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,Charging,NoError,No error.,1,Blue,1,{20,7984,26},{0,0},{C,11936,6044,12112},0,0,310,2022-09-21T13:56:50Z,1,3,{0,0,0,0,0,0,0,0,0},240,16,4,112,0,260,160,0
            ocpp.0	2022-09-21 16:11:53.660	info	Received MeterValues from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 16:11:58.377	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,Charging,NoError,No error.,1,Blue,1,{20,7984,26},{0,0},{C,11936,6043,12112},0,0,330,2022-09-21T14:11:53Z,1,3,{0,0,0,0,0,0,0,0,0},260,15,4,112,0,290,160,0
            ocpp.0	2022-09-21 16:12:43.852	info	Got terminate signal TERMINATE_YOURSELF
            ocpp.0	2022-09-21 16:12:43.861	info	terminating
            ocpp.0	2022-09-21 16:12:43.862	info	Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
            ocpp.0	2022-09-21 16:12:49.701	info	starting. Version 0.7.0 (non-npm: foxriver76/ioBroker.ocpp#a7c06c513c0e8c6272a10deddd07152bc6efbed7) in /opt/iobroker/node_modules/iobroker.ocpp, node: v16.17.0, js-controller: 4.0.23
            ocpp.0	2022-09-21 16:12:49.743	info	Starting OCPP Server
            ocpp.0	2022-09-21 16:12:49.815	info	Server listening on port 9220
            ocpp.0	2022-09-21 16:13:23.494	info	New valid connection from "http://192.168.178.80:9220/EVB-XXXXXXXXX" (http/ocpp1.6)
            ocpp.0	2022-09-21 16:13:23.551	info	New device connected: "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 16:13:23.555	info	Requesting BootNotification from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 16:13:24.595	info	Requesting StatusNotification from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 16:13:28.345	info	Received boot notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 16:13:28.600	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": Charging
            ocpp.0	2022-09-21 16:13:33.486	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,Charging,NoError,No error.,1,Blue,1,{20,7984,26},{0,0},{C,11936,6041,12112},0,0,330,2022-09-21T14:13:28Z,1,3,{0,0,0,0,0,0,0,0,0},260,15,4,112,0,290,160,0
            ocpp.0	2022-09-21 16:13:54.604	warn	Could not request states of "http://192.168.178.80:9220/EVB-XXXXXXXXX": Timeout for message 17557d23-e18f-4a14-89f4-3147f46615ff
            ocpp.0	2022-09-21 16:14:32.775	info	Loglevel changed from "info" to "silly"
            ocpp.0	2022-09-21 16:15:18.339	debug	{"commandOcpp":"Heartbeat"}
            ocpp.0	2022-09-21 16:15:18.341	debug	Received heartbeat from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 16:15:59.639	debug	Sending RemoteStopTransaction for http://192_168_178_80:9220/EVB-XXXXXXXXX
            ocpp.0	2022-09-21 16:16:05.078	debug	{"transactionId":1,"idTag":"048EAB728E6781","timestamp":"2022-09-21T14:16:04Z","meterStop":0,"reason":"Remote","commandOcpp":"StopTransaction"}
            ocpp.0	2022-09-21 16:16:05.079	info	Received stop transaction from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 16:16:05.695	debug	{"connectorId":1,"status":"Finishing","errorCode":"NoError","timestamp":"2022-09-21T14:16:05Z","commandOcpp":"StatusNotification"}
            ocpp.0	2022-09-21 16:16:05.696	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": Finishing
            ocpp.0	2022-09-21 16:16:09.338	debug	{"vendorId":"EV-BOX","messageId":"evbStatusNotification","data":"1,Finishing,NoError,No error.,0,Green,0,{20,7984,100},{0,0},{C,11936,6156,61596},0,0,330,2022-09-21T14:16:05Z,0,3,{0,0,0,0,0,0,0,0,0},260,9,3,112,0,300,900,0","commandOcpp":"DataTransfer"}
            ocpp.0	2022-09-21 16:16:09.339	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,Finishing,NoError,No error.,0,Green,0,{20,7984,100},{0,0},{C,11936,6156,61596},0,0,330,2022-09-21T14:16:05Z,0,3,{0,0,0,0,0,0,0,0,0},260,9,3,112,0,300,900,0
            ocpp.0	2022-09-21 16:16:13.327	debug	{"commandOcpp":"Heartbeat"}
            ocpp.0	2022-09-21 16:16:13.327	debug	Received heartbeat from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 16:16:29.359	debug	Sending SetChargingProfile for http://192_168_178_80:9220/EVB-XXXXXXXXX
            ocpp.0	2022-09-21 16:16:29.518	error	Cannot execute command "chargeLimit" for "http://192_168_178_80:9220/EVB-XXXXXXXXX": Sender's message does not comply with protocol specification.
            ocpp.0	2022-09-21 16:16:40.054	debug	Sending RemoteStartTransaction for http://192_168_178_80:9220/EVB-XXXXXXXXX: {"connectorId":1,"idTag":"048BEAB728E6781","chargingProfile":{"chargingProfileId":1,"stackLevel":0,"chargingProfilePurpose":"TxDefaultProfile","chargingProfileKind":"Recurring","recurrencyKind":"Daily","chargingSchedule":{"duration":86400,"startSchedule":"2013-01-01T00:00Z","chargingRateUnit":"W","chargingSchedulePeriod":[{"startPeriod":0,"limit":8000}]}}}
            ocpp.0	2022-09-21 16:16:40.436	error	Cannot execute command "transactionActive" for "http://192_168_178_80:9220/EVB-XXXXXXXXX": Sender's message does not comply with protocol specification.
            ocpp.0	2022-09-21 16:17:01.444	debug	Sending RemoteStopTransaction for http://192_168_178_80:9220/EVB-XXXXXXXXX
            ocpp.0	2022-09-21 16:17:05.951	debug	Sending ChangeAvailability for http://192_168_178_80:9220/EVB-XXXXXXXXX: Inoperative
            ocpp.0	2022-09-21 16:17:06.349	debug	{"connectorId":1,"status":"Unavailable","errorCode":"NoError","timestamp":"2022-09-21T14:17:06Z","commandOcpp":"StatusNotification"}
            ocpp.0	2022-09-21 16:17:06.350	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": Unavailable
            ocpp.0	2022-09-21 16:17:06.398	debug	{"vendorId":"EV-BOX","messageId":"evbStatusNotification","data":"1,Unavailable,NoError,No error.,0,Red,0,{20,7984,100},{0,0},{B,11934,9132,61568},0,0,330,2022-09-21T14:17:06Z,0,3,{0,0,0,0,0,0,0,0,0},260,1,1,112,0,300,900,0","commandOcpp":"DataTransfer"}
            ocpp.0	2022-09-21 16:17:06.400	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,Unavailable,NoError,No error.,0,Red,0,{20,7984,100},{0,0},{B,11934,9132,61568},0,0,330,2022-09-21T14:17:06Z,0,3,{0,0,0,0,0,0,0,0,0},260,1,1,112,0,300,900,0
            ocpp.0	2022-09-21 16:17:08.314	debug	{"commandOcpp":"Heartbeat"}
            ocpp.0	2022-09-21 16:17:08.315	debug	Received heartbeat from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 16:17:12.444	debug	Sending ChangeAvailability for http://192_168_178_80:9220/EVB-XXXXXXXXX: Operative
            ocpp.0	2022-09-21 16:17:12.772	debug	{"connectorId":1,"status":"Finishing","errorCode":"NoError","timestamp":"2022-09-21T14:17:12Z","commandOcpp":"StatusNotification"}
            ocpp.0	2022-09-21 16:17:12.773	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": Finishing
            ocpp.0	2022-09-21 16:17:12.890	debug	{"vendorId":"EV-BOX","messageId":"evbStatusNotification","data":"1,Finishing,NoError,No error.,0,Green,0,{20,7984,100},{0,0},{B,11935,9132,61568},0,0,330,2022-09-21T14:17:12Z,0,3,{0,0,0,0,0,0,0,0,0},260,1,2,112,0,300,900,0","commandOcpp":"DataTransfer"}
            ocpp.0	2022-09-21 16:17:12.891	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,Finishing,NoError,No error.,0,Green,0,{20,7984,100},{0,0},{B,11935,9132,61568},0,0,330,2022-09-21T14:17:12Z,0,3,{0,0,0,0,0,0,0,0,0},260,1,2,112,0,300,900,0
            ocpp.0	2022-09-21 16:17:20.473	debug	Sending RemoteStartTransaction for http://192_168_178_80:9220/EVB-XXXXXXXXX: {"connectorId":1,"idTag":"048BEAB728E6781","chargingProfile":{"chargingProfileId":1,"stackLevel":0,"chargingProfilePurpose":"TxDefaultProfile","chargingProfileKind":"Recurring","recurrencyKind":"Daily","chargingSchedule":{"duration":86400,"startSchedule":"2013-01-01T00:00Z","chargingRateUnit":"W","chargingSchedulePeriod":[{"startPeriod":0,"limit":8000}]}}}
            ocpp.0	2022-09-21 16:17:20.616	error	Cannot execute command "transactionActive" for "http://192_168_178_80:9220/EVB-XXXXXXXXX": Sender's message does not comply with protocol specification.
            ocpp.0	2022-09-21 16:18:03.322	debug	{"commandOcpp":"Heartbeat"}
            ocpp.0	2022-09-21 16:18:03.322	debug	Received heartbeat from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 16:18:33.622	debug	{"idTag":"048EAB728E6781","commandOcpp":"Authorize"}
            ocpp.0	2022-09-21 16:18:33.623	info	Received Authorization Request from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 16:18:36.216	debug	{"connectorId":1,"status":"Preparing","errorCode":"NoError","timestamp":"2022-09-21T14:18:35Z","commandOcpp":"StatusNotification"}
            ocpp.0	2022-09-21 16:18:36.217	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": Preparing
            ocpp.0	2022-09-21 16:18:36.273	debug	{"vendorId":"EV-BOX","messageId":"evbStatusNotification","data":"1,Preparing,NoError,No error.,0,Off,1,{20,7984,100},{0,0},{B,11936,9132,61568},0,0,330,2022-09-21T14:18:35Z,0,3,{0,0,0,0,0,0,0,0,0},260,0,0,125,0,300,900,0","commandOcpp":"DataTransfer"}
            ocpp.0	2022-09-21 16:18:36.274	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,Preparing,NoError,No error.,0,Off,1,{20,7984,100},{0,0},{B,11936,9132,61568},0,0,330,2022-09-21T14:18:35Z,0,3,{0,0,0,0,0,0,0,0,0},260,0,0,125,0,300,900,0
            ocpp.0	2022-09-21 16:18:37.696	debug	{"connectorId":1,"status":"SuspendedEVSE","errorCode":"NoError","info":"B;330","timestamp":"2022-09-21T14:18:37Z","commandOcpp":"StatusNotification"}
            ocpp.0	2022-09-21 16:18:37.697	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": SuspendedEVSE
            ocpp.0	2022-09-21 16:18:37.887	debug	{"connectorId":1,"status":"SuspendedEV","errorCode":"NoError","info":"B;330","timestamp":"2022-09-21T14:18:37Z","commandOcpp":"StatusNotification"}
            ocpp.0	2022-09-21 16:18:37.888	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": SuspendedEV
            ocpp.0	2022-09-21 16:18:40.327	debug	{"connectorId":1,"idTag":"048EAB728E6781","timestamp":"2022-09-21T14:18:36Z","meterStart":0,"commandOcpp":"StartTransaction"}
            ocpp.0	2022-09-21 16:18:40.328	info	Received Start transaction from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            ocpp.0	2022-09-21 16:18:42.407	debug	{"connectorId":1,"status":"Charging","errorCode":"NoError","info":"C;330","timestamp":"2022-09-21T14:18:42Z","commandOcpp":"StatusNotification"}
            ocpp.0	2022-09-21 16:18:42.408	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX": Charging
            ocpp.0	2022-09-21 16:18:45.345	debug	{"vendorId":"EV-BOX","messageId":"evbStatusNotification","data":"1,SuspendedEVSE,NoError,No error.,0,Yellow,1,{20,7983,10},{0,0},{B,11936,8752,8393},0,0,330,2022-09-21T14:18:37Z,1,3,{0,0,0,0,0,0,0,0,0},260,0,0,125,0,300,60,0","commandOcpp":"DataTransfer"}
            ocpp.0	2022-09-21 16:18:45.346	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,SuspendedEVSE,NoError,No error.,0,Yellow,1,{20,7983,10},{0,0},{B,11936,8752,8393},0,0,330,2022-09-21T14:18:37Z,1,3,{0,0,0,0,0,0,0,0,0},260,0,0,125,0,300,60,0
            ocpp.0	2022-09-21 16:18:50.344	debug	{"vendorId":"EV-BOX","messageId":"evbStatusNotification","data":"1,SuspendedEV,NoError,No error.,0,Yellow,1,{20,7984,10},{0,0},{B,11936,8639,12153},0,0,330,2022-09-21T14:18:37Z,1,3,{0,0,0,0,0,0,0,0,0},260,0,0,125,0,300,60,0","commandOcpp":"DataTransfer"}
            ocpp.0	2022-09-21 16:18:50.345	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,SuspendedEV,NoError,No error.,0,Yellow,1,{20,7984,10},{0,0},{B,11936,8639,12153},0,0,330,2022-09-21T14:18:37Z,1,3,{0,0,0,0,0,0,0,0,0},260,0,0,125,0,300,60,0
            ocpp.0	2022-09-21 16:18:55.345	debug	{"vendorId":"EV-BOX","messageId":"evbStatusNotification","data":"1,Charging,NoError,No error.,1,Blue,1,{20,7984,10},{0,0},{C,11936,5852,12160},0,0,330,2022-09-21T14:18:42Z,1,3,{0,0,0,0,0,0,0,0,0},260,1,0,117,0,300,60,0","commandOcpp":"DataTransfer"}
            ocpp.0	2022-09-21 16:18:55.346	info	Received DataTransfer from "http://192.168.178.80:9220/EVB-XXXXXXXXX" with id "evbStatusNotification": 1,Charging,NoError,No error.,1,Blue,1,{20,7984,10},{0,0},{C,11936,5852,12160},0,0,330,2022-09-21T14:18:42Z,1,3,{0,0,0,0,0,0,0,0,0},260,1,0,117,0,300,60,0
            ocpp.0	2022-09-21 16:18:58.336	debug	{"commandOcpp":"Heartbeat"}
            ocpp.0	2022-09-21 16:18:58.338	debug	Received heartbeat from "http://192.168.178.80:9220/EVB-XXXXXXXXX"
            

            foxriver76 1 Reply Last reply Reply Quote 0
            • foxriver76
              foxriver76 Developer @Meister Mopper last edited by

              @meister-mopper hm Schade, dann scheint die WB kein Anpassung der Ladeleistung zu unterstützen, schreib einfach mal in den State für chargeLimit ein String oder null rein, dann sollte er es gehen natürlich nach wie vor ohne Ladeleistungsanpassung.

              Meister Mopper 1 Reply Last reply Reply Quote 0
              • Meister Mopper
                Meister Mopper @foxriver76 last edited by

                @foxriver76
                Jup, funktioniert. Die Ladeleistung wollte ich aber ohnehin nicht geregelt haben. Bei meiner Konstellation sind 3.600 W genau richtig.

                beb41230-add3-44be-9537-c7dcd0958cc9-grafik.png

                1 Reply Last reply Reply Quote 0
                • Meister Mopper
                  Meister Mopper last edited by

                  @foxriver76

                  Hier noch ein wenig Futter für Alpha.

                  Gestern und heute reproduzierbar:

                  Das Beenden eines Ladevorgangs ist wegen timeout nicht möglich. Erst nach einem Neustart des Adapters kann ich beenden.

                  Hier das log:

                  ocpp.0	2022-10-05 17:46:46.971	error	Cannot execute command "transactionActive" for "http://192_168_178_80:9220/XXXXXXXXX": Timeout for message b95c484c-4bdc-48cf-9553-98a1958e427b
                  ocpp.0	2022-10-05 17:47:18.755	info	Got terminate signal TERMINATE_YOURSELF
                  ocpp.0	2022-10-05 17:47:18.936	info	terminating
                  ocpp.0	2022-10-05 17:47:18.938	info	Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                  ocpp.0	2022-10-05 17:47:24.009	debug	Redis Objects: Use Redis connection: 192.168.178.10:9001
                  ocpp.0	2022-10-05 17:47:24.071	debug	Objects client ready ... initialize now
                  ocpp.0	2022-10-05 17:47:24.073	debug	Objects create System PubSub Client
                  ocpp.0	2022-10-05 17:47:24.075	debug	Objects create User PubSub Client
                  ocpp.0	2022-10-05 17:47:24.175	debug	Objects client initialize lua scripts
                  ocpp.0	2022-10-05 17:47:24.184	debug	Objects connected to redis: 192.168.178.10:9001
                  ocpp.0	2022-10-05 17:47:24.236	debug	Redis States: Use Redis connection: 192.168.178.10:6379
                  ocpp.0	2022-10-05 17:47:24.246	debug	States create System PubSub Client
                  ocpp.0	2022-10-05 17:47:24.248	debug	States create User PubSub Client
                  ocpp.0	2022-10-05 17:47:24.260	debug	States connected to redis: 192.168.178.10:6379
                  ocpp.0	2022-10-05 17:47:24.434	info	starting. Version 0.7.0 in /opt/iobroker/node_modules/iobroker.ocpp, node: v16.17.1, js-controller: 4.0.23
                  ocpp.0	2022-10-05 17:47:24.476	info	Starting OCPP Server
                  ocpp.0	2022-10-05 17:47:24.514	info	Server listening on port 9220
                  ocpp.0	2022-10-05 17:47:58.342	debug	Connection from "http://192.168.178.80:9220/XXXXXXXXX" with credentials "undefined", protocol: "http", OCPP: ocpp1.6
                  ocpp.0	2022-10-05 17:47:58.344	info	New valid connection from "http://192.168.178.80:9220/XXXXXXXXX" (http/ocpp1.6)
                  ocpp.0	2022-10-05 17:47:58.395	info	New device connected: "http://192.168.178.80:9220/XXXXXXXXX"
                  ocpp.0	2022-10-05 17:47:58.397	info	Requesting BootNotification from "http://192.168.178.80:9220/XXXXXXXXX"
                  ocpp.0	2022-10-05 17:47:58.479	debug	{"commandOcpp":"Heartbeat"}
                  ocpp.0	2022-10-05 17:47:58.480	debug	Received heartbeat from "http://192.168.178.80:9220/XXXXXXXXX"
                  ocpp.0	2022-10-05 17:47:59.433	info	Requesting StatusNotification from "http://192.168.178.80:9220/XXXXXXXXX"
                  ocpp.0	2022-10-05 17:48:03.308	debug	{"chargePointVendor":"EV-BOX","chargePointModel":"G4E-WIFI","chargePointSerialNumber":"21312507","firmwareVersion":"P0422B0422v0.211223_U6.0.0-050","commandOcpp":"BootNotification"}
                  ocpp.0	2022-10-05 17:48:03.309	info	Received boot notification from "http://192.168.178.80:9220/XXXXXXXXX"
                  ocpp.0	2022-10-05 17:48:03.782	debug	{"connectorId":1,"status":"Charging","errorCode":"NoError","info":"C;370","timestamp":"2022-10-05T15:48:03Z","commandOcpp":"StatusNotification"}
                  ocpp.0	2022-10-05 17:48:03.783	info	Received Status Notification from "http://192.168.178.80:9220/XXXXXXXXX": Charging
                  ocpp.0	2022-10-05 17:48:08.325	debug	{"vendorId":"EV-BOX","messageId":"evbStatusNotification","data":"1,Charging,NoError,No error.,1,Blue,1,{20,7984,26},{0,0},{C,11920,6044,12159},0,0,370,2022-10-05T15:48:03Z,1,3,{0,0,0,0,0,0,0,0,0},300,14,5,113,0,360,160,0","commandOcpp":"DataTransfer"}
                  ocpp.0	2022-10-05 17:48:08.326	info	Received DataTransfer from "http://192.168.178.80:9220/XXXXXXXXX" with id "evbStatusNotification": 1,Charging,NoError,No error.,1,Blue,1,{20,7984,26},{0,0},{C,11920,6044,12159},0,0,370,2022-10-05T15:48:03Z,1,3,{0,0,0,0,0,0,0,0,0},300,14,5,113,0,360,160,0
                  ocpp.0	2022-10-05 17:48:29.439	warn	Could not request states of "http://192.168.178.80:9220/XXXXXXXXX": Timeout for message 3dbb5093-d330-4511-86e4-6e16480013ec
                  ocpp.0	2022-10-05 17:48:30.797	debug	Sending RemoteStopTransaction for http://192_168_178_80:9220/XXXXXXXXX
                  ocpp.0	2022-10-05 17:48:36.144	debug	{"transactionId":1,"idTag":"048EAB728E6781","timestamp":"2022-10-05T15:48:35Z","meterStop":0,"reason":"Remote","commandOcpp":"StopTransaction"}
                  ocpp.0	2022-10-05 17:48:36.145	info	Received stop transaction from "http://192.168.178.80:9220/XXXXXXXXX"
                  ocpp.0	2022-10-05 17:48:36.956	debug	{"connectorId":1,"status":"Finishing","errorCode":"NoError","timestamp":"2022-10-05T15:48:36Z","commandOcpp":"StatusNotification"}
                  ocpp.0	2022-10-05 17:48:36.957	info	Received Status Notification from "http://192.168.178.80:9220/XXXXXXXXX": Finishing
                  ocpp.0	2022-10-05 17:48:40.315	debug	{"vendorId":"EV-BOX","messageId":"evbStatusNotification","data":"1,Finishing,NoError,No error.,0,Green,0,{20,7984,100},{0,0},{C,11920,6156,61616},0,0,370,2022-10-05T15:48:36Z,0,3,{0,0,0,0,0,0,0,0,0},310,13,4,113,0,360,900,0","commandOcpp":"DataTransfer"}
                  ocpp.0	2022-10-05 17:48:40.316	info	Received DataTransfer from "http://192.168.178.80:9220/XXXXXXXXX" with id "evbStatusNotification": 1,Finishing,NoError,No error.,0,Green,0,{20,7984,100},{0,0},{C,11920,6156,61616},0,0,370,2022-10-05T15:48:36Z,0,3,{0,0,0,0,0,0,0,0,0},310,13,4,113,0,360,900,0
                  
                  foxriver76 1 Reply Last reply Reply Quote 0
                  • foxriver76
                    foxriver76 Developer @Meister Mopper last edited by

                    @meister-mopper Die 0.8.0 fixed das eventuell. Die Struktur hat sich allerdings geändert um Charger mit mehreren Connectoren zu unterstützen.

                    1 Reply Last reply Reply Quote 0
                    • Meister Mopper
                      Meister Mopper last edited by

                      @foxriver76

                      Konnte heute mal wieder testen:
                      Version 0.8.0

                      Ein Ladestart war erst möglich, nachdem ich den Adapter gestoppt, den kompletten Objektbaum gelöscht und den Adapter neu gestartet hatte.

                      Bei Ladestopp tat sich nichts ( because no active transaction found), also habe ich versucht, available auf false zu stellen. Auch nichts. Letztlich habe ich den Stecker gezogen.

                      ocpp.0	2022-10-28 16:19:20.562	debug	Sending RemoteStopTransaction for http://192_168_178_80:9220/XXXXXXXXX.1
                      ocpp.0	2022-10-28 16:19:20.563	warn	Cannot stop transaction on http://192_168_178_80:9220/EVB-XXXXXXXXX.1, because no active transaction found
                      ocpp.0	2022-10-28 16:19:30.904	debug	Sending ChangeAvailability for http://192_168_178_80:9220/EVB-XXXXXXXXX.1: Inoperative
                      ocpp.0	2022-10-28 16:19:31.257	debug	{"connectorId":1,"status":"Charging","errorCode":"NoError","info":"C;400","timestamp":"2022-10-28T14:19:30Z","commandOcpp":"StatusNotification"}
                      ocpp.0	2022-10-28 16:19:31.259	info	Received Status Notification from "http://192.168.178.80:9220/EVB-XXXXXXXXX.1": Charging
                      
                      Soeni 1 Reply Last reply Reply Quote 0
                      • Soeni
                        Soeni @Meister Mopper last edited by

                        hallo, ich würde gerne den GO-E Charger testen und habe den adapter eingerichtet. Im Go E habe ich die Adresse mit Port eingetragen. Der Go E meldet keine Verbindung. Gibt es eine Debugmöglichkeit? Bin ich der erste, der den Go E testet?

                        Meister Mopper 1 Reply Last reply Reply Quote 0
                        • Meister Mopper
                          Meister Mopper @Soeni last edited by

                          @soeni

                          Wie hast Du denn die Adresse mit Port eingetragen? Ich musste die IP bei meiner EVbox mit ws:// eintragen.

                          Soeni 1 Reply Last reply Reply Quote 0
                          • Soeni
                            Soeni @Meister Mopper last edited by

                            @meister-mopper

                            Wunderbar, das war es. Damit kann ich bestätigen, dass es mit dem Go E auch geht. Zumindest die initiale Verbindung. Daten sehen erst mal mau aus, ich muss aber erst mal einen Ladevorgang starten um das zu beurteilen. Vielen dank in jedem Fall schon mal.

                            1 Reply Last reply Reply Quote 0
                            • F
                              frank11 last edited by frank11

                              Erstmal vielen Dank für den Adapter @foxriver76 , funktioniert sehr gut.

                              Ich nutze den DaheimLader Touch und der scheint auch ausreichend Daten zu liefern.
                              Das einzige was mich stört, ist: Daten kommen nur in kurzen Intervallen, wenn das Laden aktiv ist.
                              Die KeepAlive-Meldungen kommen zwar regelmäßig auch außerhalb des Ladezyklus, aber keine Daten, außer ich starte den Adapter neu, kann ich das beeinflussen?

                              Ich möchte auch Daten sehen, wenn kein Auto geladen wird.

                              Geht das? Wenn ja, wie?

                              foxriver76 1 Reply Last reply Reply Quote 0
                              • foxriver76
                                foxriver76 Developer @frank11 last edited by

                                @frank11 Aktuell kann man die Konfiguration der WB, wie oft reported wird etc. leider nicht ändern. Leider scheint die Library nicht korrekt mit der Konfig zu interagieren. Ich habe in einem Issue mir mal noch eine andere Lib vermerkt, grundsätzlich ist die Idee, Sachen wie das Report Intervall etc ändern zu können. Nur die Zeit fehlt wie so oft um die andere Lib mal zu testen.

                                F 1 Reply Last reply Reply Quote 0
                                • F
                                  frank11 @foxriver76 last edited by

                                  @foxriver76 Alles klar, verstehe.

                                  Ich warte dann einfach. 😄

                                  Mir reicht das im Moment wie es ist, um meinen Stromverbrauch mit Grafana an meinen Arbeitgeber zu reporten für die Abrechnung.

                                  Alles andere ist Nice to have.

                                  1 Reply Last reply Reply Quote 0
                                  • G
                                    gklank @foxriver76 last edited by gklank

                                    @foxriver76 Hallo,

                                    ich bin absolut neu mit dem IOBroker unterwegs, daher doch noch etliche Lücken.
                                    Gerne nehme ich Tips oder Instruktionen auf...

                                    Ich möchte von meinen Node-Red Lösungen auf den IOBroker umzustellen.
                                    Da das Wenige was ich mit der Wallbox machen will, bzw. mit Node-Red gemacht habe, lässt mich hier schon noch hoffen...
                                    Letztendlich möchte ich den aktuelle Verbrauch auslesen, was schon geht, passt!!!
                                    Allerdings möchte ich auch die Ladeleistung einstellen können.

                                    Ich benutze die Wallbox von Mennekes:
                                    Amtron Professional PNC 22 C2, Wallbox 1385202

                                    Ich habe den ocpp Adapter installiert und bekomme die Verbindung zu meiner Wallbox:
                                    ocpp.0 2022-12-10 21:51:13.653 info Received MeterValues from "/ocpp/1365202.00069"
                                    ocpp.0 2022-12-10 21:51:12.730 info Received Status Notification from "/ocpp/1365202.00069": Available
                                    ocpp.0 2022-12-10 21:51:12.612 info Received Status Notification from "/ocpp/1365202.00069": Available
                                    ocpp.0 2022-12-10 21:51:09.666 info Sending GetConfiguration to "/ocpp/1365202.00069"
                                    ocpp.0 2022-12-10 21:51:08.811 info Received MeterValues from "/ocpp/1365202.00069"
                                    ocpp.0 2022-12-10 21:51:08.712 info Received Status Notification from "/ocpp/1365202.00069": Available
                                    ocpp.0 2022-12-10 21:51:08.578 info Requesting MeterValues from "/ocpp/1365202.00069"
                                    ocpp.0 2022-12-10 21:51:08.568 info Received Status Notification from "/ocpp/1365202.00069": Available
                                    ocpp.0 2022-12-10 21:51:08.431 info Received Status Notification from "/ocpp/1365202.00069": Available
                                    ocpp.0 2022-12-10 21:51:08.142 info Received Status Notification from "/ocpp/1365202.00069": Available
                                    ocpp.0 2022-12-10 21:51:08.002 info Received Status Notification from "/ocpp/1365202.00069": Available
                                    ocpp.0 2022-12-10 21:51:07.610 info Received boot notification from "/ocpp/1365202.00069"
                                    ocpp.0 2022-12-10 21:51:07.508 info Requesting StatusNotification from "/ocpp/1365202.00069"
                                    ocpp.0 2022-12-10 21:51:07.506 info New device connected: "/ocpp/1365202.00069"
                                    ocpp.0 2022-12-10 21:51:07.323 info New valid connection from "/ocpp/1365202.00069" (http/ocpp1.6)

                                    Um die Ladeleistung einzustellen muss man dem einen Parameter die entsprechende Amperezahl mitgeben:
                                    Ich meine sogar, dass es nur ein String ist, dann entsprechend 6 Ampere für 3,6 kW, oder eben 16 für 11 kW, oder 32 A für 22 kW.

                                    Dies schicke ich wie folgt über die Nodered-Node an die Wallbox:
                                    Eingepackt in dieses Array:
                                    Wert = "6"
                                    ger[0] = 2;
                                    ger[1] = "b797fb70-3a57-11ed-b390-c15e4f34211c";
                                    ger[2] = "ChangeConfiguration";
                                    ger[3] = {
                                    key: "OperatorCurrentLimit",
                                    readonly: false,
                                    value: power
                                    }

                                    Der ger[1] hat sicherlich keinerlei Bedeutung als irgendein aktueller Schlüssel für dieses Kommando.
                                    Da habe ich schon alles Mögliche geschickt, ohne dass es weder negativ noch positiv auffiel.

                                    Letztendlich muss halt der "key: "OperatorCurrentLimit" auf die entsprechende Amperezahl gesetzt werden.

                                    Diesen Key gibt es aber in dem entsprechenden Objekt im IOBroker nicht.

                                    Ich würde jetzt meinen, dass ich den mal "frech" anlegen sollte und dann darüber den Wert ändern.
                                    Bzw. gerade mal gemacht:

                                    Sieht dann so aus:
                                    {
                                    "common": {
                                    "name": "OperatorCurrentLimit",
                                    "desc": "Manuell erzeugt",
                                    "role": "state",
                                    "type": "number",
                                    "read": true,
                                    "write": true,
                                    "def": ""
                                    },
                                    "type": "state",
                                    "native": {},
                                    "_id": "ocpp.0./ocpp/1365202_00069.OperatorCurrentLimit",
                                    "acl": {
                                    "object": 1636,
                                    "state": 1636,
                                    "owner": "system.user.admin",
                                    "ownerGroup": "system.group.administrator"
                                    },
                                    "from": "system.adapter.admin.0",
                                    "user": "system.user.admin",
                                    "ts": 1670707273587
                                    }

                                    Aber wenn ich jetzt einen anderen Wert im iobroker eintrage und speichere, dann sehe ich im Protokoll keinen Traffic zur Wallbox hin.
                                    Dementsprechend wird auch die Änderung nicht bestätigt und steht somit verständlicherweise auf "false".

                                    Und in der Wallbox ist der OperatorCurrentLimit nicht verändert.

                                    Ich weiß, ein etwas wildes Probieren...

                                    Habt Ihr mir noch einige Tipps bzw. Instruktionen?

                                    Grüße

                                    Gerhard

                                    G G 2 Replies Last reply Reply Quote 0
                                    • G
                                      gklank @gklank last edited by

                                      @gklank Hallo,

                                      ich habe den Loglevel umgestellt und kann jetzt die Message zur Wallbox sehen.
                                      Aber eben keine Rückmeldung zur vermeintlichen Änderung des OperatorCurrentLimits, zwecks Leistungsbeschränkung:

                                      ocpp.0 2022-12-12 01:10:45.451 debug Received heartbeat from "/ocpp/1365202.00069"
                                      ocpp.0 2022-12-12 01:10:45.450 debug {"commandOcpp":"Heartbeat"}
                                      ocpp.0 2022-12-12 01:10:20.331 silly States user redis pmessage ocpp.0.*/ocpp.0./ocpp/1365202_00069.1.OperatorCurrentLimit:{"val":"6","ack":false,"ts":1670803820327,"q":0,"from":"system.adapter.admin.0","user":"system.user.admin","lc":1670803820327}

                                      Grüße

                                      Gerhard

                                      G 1 Reply Last reply Reply Quote 0
                                      • S
                                        sunny9999 last edited by

                                        Hallo @all.......
                                        hab eine Charge Amps Aura Wallbox ( 2 Ausgänge a 22kw)
                                        Die Daten kommen von deren Cloud, hab denen die Daten meines Servers gegeben kommt über wss Protokoll sauber über nen NGINX rein.....
                                        Adapter ist grün
                                        Datepunkte wurden angelegt (für beide Ladeports)
                                        ObjektScreenshot 2022-12-12 101452.jpg
                                        Der hat für den Meter aber ein Verzeichnis angelegt ??
                                        Insgesamt kommen aber keine Daten rein...??
                                        Error Log sieht wie folgt aus :
                                        LogScreenshot 2022-12-12 101437.jpg
                                        Jemand eine Idee wie bzw. wo der Bug liegt ?
                                        Danke und thxs
                                        Sunny

                                        H 1 Reply Last reply Reply Quote 0
                                        • H
                                          hansano @sunny9999 last edited by hansano

                                          Ich habe Zugangsdaten für die Config-App und das Webportal von ABB bekommen. Soweit so gut.

                                          Ist das normal das ich andere Web-Accounts einsehen und andere App-Accounts sogar sperren/editieren kann? Ich kann sogar neue Accounts anlegen. Einen hab ich mir mal gegönnt. Also wer einen Account brauch, kann sich bei mir melden :). Ist wohl die neue Art Kosten zu sparen bei ABB.

                                          Unbenannt1.png

                                          Unbenannt.png

                                          Denke eher nicht oder?

                                          @sunny9999
                                          sorry, versehentlich als Reply auf deinen Post

                                          1 Reply Last reply Reply Quote 1
                                          • G
                                            gklank @gklank last edited by

                                            @gklank Hallo,

                                            um unnötige Arbeit für das ocpp Adapter zu vermeiden:

                                            • das Modbus Adapter funktioniert mit der "Amtron Professional PNC 22 C2, Wallbox 1385202" zumindestens in der Form, wie ich damit umgehen möchte.
                                              D.h. ich kann die Leistung der aktuellen Ladung auslesen, kann die Ladeleistung ändern - auch in der Ladephase - und weitere Informartionen auslesen...

                                            Eine gute Erklärung für den Modbus Adapter fand ich hier:
                                            https://www.youtube.com/watch?v=K-95q0sJ0G8&t=378s

                                            Danke an den Kollegen, der den Youtube dafür erstellt hat!!!

                                            • hoffentlich ist dies keine Werbung oder vielleicht nicht ok den Link hier reinzustellen.
                                              Wenn falsch, dann sorry und die Bitte den Link dann rauszulöschen.

                                            Zusätzlich hatte ich noch eine falsche "Annahme" zur Leistungssteuerung der Wallbox.
                                            Hier der funktionierende Tipp:

                                            • den "OPERATOR_CURRENT_LIMIT" ist für den passenden Leistungsbezug, der Wert der maximal aus der Wand kommt
                                              dieser Wert kann nur über das Webfrontend oder ocpp geändert werden.
                                              den wollte ich zur Steuerung der Ladeleistung verwenden, was mit modbus nicht geht, bzw. dazu gar nicht gedacht ist.
                                            • der "Steuerdatenpunkt" um die Ladung temporär zu stoppen (Wert = 0) oder zu verändern (6A für 3.6kW, 16A für 11kW, 32A für 22kW) wird über "HEMS_CURRENT_LIMIT" mit Register 1000 gesteuert

                                            Somit habe ich jetzt die Steuerung für mich wie ich sie brauche.

                                            Vielen Dank für die hier versuchte Hilfe.

                                            Grüße

                                            Gerhard

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            772
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            adapter ocpp wallbox
                                            48
                                            440
                                            78004
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo