    • A
      Andre105 @mickym last edited by

      @mickym
      Gefunden,

      3566b115-59bc-4221-adf6-21e2a862b6ed-image.png

      Der LS Filter reicht?

      mickym 1 Reply Last reply Reply Quote 0
      • mickym
        mickym Most Active @Andre105 last edited by mickym

        @andre105 Genau. Ich hab Dir ja den Flow exportiert - musst ja nur importieren und dann kannst alles auf Deine Bedürfnisse anpassen.

        In dem LightScheduler gibst Du einmal Deine Standortdaten ein, damit die Astrofunktion korrekt berrechnen kann:

        b931a006-65a1-438e-9b0b-95afff68a2d2-image.png

        In dem Filter gibst Du einfach immer den maximalen Zeitraum an, an dem Licht geschaltet werden soll. Ich hab mal jeden Wochentag von 16:00-9:00 genommen. Mit dem Anhaken - only wenn Dark wird das dann entsprechend dem Sonnenstand angepasst. Also im Sommer wird erst dann eingeschaltet wenn Dunkel ist auch wenn die Zeitvorgabe ab 16:00 ist

        Man kann dann gemäß Sonnenstand noch variieren. Das findest Du aber raus:

        39dbd504-82e2-4d9f-a9a9-05d6dd9bf2a6-image.png

        Das heißt Du kannst auch bereits vor dem Sonnenuntergang (Golden Hour) schon einschalten. Mit + ist die Sonne quasi noch sichtbar, mit - hast Du dann Dämmerzustände an den die Sonne nicht mehr sichtbar ist.

        1 Reply Last reply Reply Quote 0
        • mickym
          mickym Most Active last edited by mickym

          0333cc19-1520-4ebd-aef3-8651e3a2d4a6-image.png

          Die Verbindung vom Schalter zu der Lampe brauchst Du natürlich nicht, wenn der Shelly direkt mit der Lampe verkabelt ist. Dann geht es nur darum, den Schalterzustand für den Flow zu speichern.

          In dem Fall - kann man sich aber auch den Schaltzustand des Schalters (über die iobroker get Node) direkt über die Datenpunkte des iobrokers holen. Das schaut dann wieder etwas einfacher aus:

          7efece53-30c5-4992-99f1-106dabf36142-image.png

          [
             {
                 "id": "04eb923ce21c3658",
                 "type": "light-scheduler-filter",
                 "z": "289f539dcc33814e",
                 "settings": "58906d3dbef01275",
                 "events": "[{\"start\":{\"dow\":1,\"mod\":0},\"end\":{\"dow\":1,\"mod\":540}},{\"start\":{\"dow\":2,\"mod\":0},\"end\":{\"dow\":2,\"mod\":540}},{\"start\":{\"dow\":3,\"mod\":0},\"end\":{\"dow\":3,\"mod\":540}},{\"start\":{\"dow\":4,\"mod\":0},\"end\":{\"dow\":4,\"mod\":540}},{\"start\":{\"dow\":5,\"mod\":0},\"end\":{\"dow\":5,\"mod\":540}},{\"start\":{\"dow\":6,\"mod\":0},\"end\":{\"dow\":6,\"mod\":540}},{\"start\":{\"dow\":0,\"mod\":0},\"end\":{\"dow\":0,\"mod\":540}},{\"start\":{\"dow\":1,\"mod\":960},\"end\":{\"dow\":2,\"mod\":0}},{\"start\":{\"dow\":2,\"mod\":960},\"end\":{\"dow\":3,\"mod\":0}},{\"start\":{\"dow\":3,\"mod\":960},\"end\":{\"dow\":4,\"mod\":0}},{\"start\":{\"dow\":4,\"mod\":960},\"end\":{\"dow\":5,\"mod\":0}},{\"start\":{\"dow\":5,\"mod\":960},\"end\":{\"dow\":6,\"mod\":0}},{\"start\":{\"dow\":6,\"mod\":960},\"end\":{\"dow\":0,\"mod\":0}},{\"start\":{\"dow\":0,\"mod\":960},\"end\":{\"dow\":1,\"mod\":0}}]",
                 "name": "Wenn Dunkel",
                 "onlyWhenDark": true,
                 "scheduleRndMax": 0,
                 "sunElevationThreshold": "0",
                 "sunShowElevationInStatus": true,
                 "x": 2860,
                 "y": 4400,
                 "wires": [
                     [
                         "bd829e5ebcd85f84"
                     ],
                     [
                         "895f5358aa2d279a"
                     ]
                 ]
             },
             {
                 "id": "19d9d6fc69d82573",
                 "type": "ioBroker in",
                 "z": "289f539dcc33814e",
                 "name": "",
                 "topic": "BWM1",
                 "payloadType": "value",
                 "onlyack": "",
                 "func": "all",
                 "gap": "",
                 "fireOnStart": "false",
                 "outFormat": "MQTT",
                 "x": 2310,
                 "y": 4360,
                 "wires": [
                     [
                         "7072a3785f9979d3"
                     ]
                 ]
             },
             {
                 "id": "ea81aeb7988b97ea",
                 "type": "ioBroker in",
                 "z": "289f539dcc33814e",
                 "name": "",
                 "topic": "BWM2",
                 "payloadType": "value",
                 "onlyack": "",
                 "func": "all",
                 "gap": "",
                 "fireOnStart": "false",
                 "outFormat": "MQTT",
                 "x": 2310,
                 "y": 4420,
                 "wires": [
                     [
                         "7072a3785f9979d3"
                     ]
                 ]
             },
             {
                 "id": "bd829e5ebcd85f84",
                 "type": "trigger",
                 "z": "289f539dcc33814e",
                 "name": "",
                 "op1": "true",
                 "op2": "false",
                 "op1type": "bool",
                 "op2type": "bool",
                 "duration": "1",
                 "extend": true,
                 "overrideDelay": false,
                 "units": "min",
                 "reset": "",
                 "bytopic": "all",
                 "topic": "topic",
                 "outputs": 1,
                 "x": 3070,
                 "y": 4380,
                 "wires": [
                     [
                         "ed92ce81feb63de8"
                     ]
                 ]
             },
             {
                 "id": "895f5358aa2d279a",
                 "type": "change",
                 "z": "289f539dcc33814e",
                 "name": "setze false",
                 "rules": [
                     {
                         "t": "set",
                         "p": "payload",
                         "pt": "msg",
                         "to": "false",
                         "tot": "bool"
                     }
                 ],
                 "action": "",
                 "property": "",
                 "from": "",
                 "to": "",
                 "reg": false,
                 "x": 3070,
                 "y": 4420,
                 "wires": [
                     [
                         "ed92ce81feb63de8"
                     ]
                 ]
             },
             {
                 "id": "ed92ce81feb63de8",
                 "type": "ioBroker out",
                 "z": "289f539dcc33814e",
                 "name": "",
                 "topic": "Lampe",
                 "ack": "false",
                 "autoCreate": "false",
                 "stateName": "",
                 "role": "",
                 "payloadType": "",
                 "readonly": "",
                 "stateUnit": "",
                 "stateMin": "",
                 "stateMax": "",
                 "x": 3250,
                 "y": 4400,
                 "wires": []
             },
             {
                 "id": "7072a3785f9979d3",
                 "type": "ioBroker get",
                 "z": "289f539dcc33814e",
                 "name": "",
                 "topic": "Schalter",
                 "attrname": "status",
                 "payloadType": "value",
                 "errOnInvalidState": "nothing",
                 "x": 2460,
                 "y": 4400,
                 "wires": [
                     [
                         "81780c766284f586"
                     ]
                 ]
             },
             {
                 "id": "81780c766284f586",
                 "type": "switch",
                 "z": "289f539dcc33814e",
                 "name": "Schalter = false?",
                 "property": "switch",
                 "propertyType": "msg",
                 "rules": [
                     {
                         "t": "false"
                     }
                 ],
                 "checkall": "true",
                 "repair": false,
                 "outputs": 1,
                 "x": 2650,
                 "y": 4400,
                 "wires": [
                     [
                         "04eb923ce21c3658"
                     ]
                 ]
             },
             {
                 "id": "58906d3dbef01275",
                 "type": "light-scheduler-settings",
                 "name": "Köln",
                 "latitude": "50.9446",
                 "longitude": "7.0115"
             }
          ]
          

          A 1 Reply Last reply Reply Quote 0
          • A
            Andre105 @mickym last edited by

            @mickym
            Ja der Schalter schaltet den Shelly,und somit geht die Lampe an.
            Kann den Schalter mit rein nehmen,falls einer den Schalter betätigt.(rein aus Gewohnheit)

            Schau mal :was bedeutet das?

            09783088-e2df-40df-9b40-a8bbe55c9553-image.png

            eae54e2f-55f2-48cb-aa79-26f42da4e8f3-image.png

            mickym 1 Reply Last reply Reply Quote 0
            • mickym
              mickym Most Active @Andre105 last edited by mickym

              @andre105 Tja generell - musst Du Dir angewöhnen in Javascript (und somit innerhalb von NodeRed generell) - Dezimalzahlen mit Punkt und nicht mit Komma anzugeben. Und wenn Du einen roten Rahmen, um ein Eingabefeld siehst, solltest Du gleich darauf achten, dass was nicht in Ordnung mit der Eingabe ist. 😉

              A 1 Reply Last reply Reply Quote 0
              • A
                Andre105 @mickym last edited by

                @mickym
                Alles klar,konnte den Fehler beheben.
                Dann probiere ich mir das mal aus.
                Danke erstmal bis hier her.:)

                mickym 1 Reply Last reply Reply Quote 0
                • mickym
                  mickym Most Active @Andre105 last edited by mickym

                  Das mit der trigger node kannst dir natürlich sparen, wenn Du das Signal der BWM direkt nutzen willst und dort die Minute einträgst. (occupancy-timeout)

                  A 1 Reply Last reply Reply Quote 0
                  • A
                    Andre105 @mickym last edited by

                    @mickym

                    Wenn ich jetzt in den Raum gehe,geht das Licht an,obwohl noch nicht dunkel.

                    Mich wundert das der Schalter nicht auf false wechselt.

                    6761f34b-abd9-4e9c-9c74-ccab3128401b-image.png

                    dfdb9ef6-5d79-41a2-9385-036a4e7f5ccc-image.png

                    mickym 1 Reply Last reply Reply Quote 0
                    • mickym
                      mickym Most Active @Andre105 last edited by mickym

                      @andre105 Ich weiß nicht, wie man den switch schalten muss - prüfe halt mal ob mit true oder false oder mit on oder off. Dann schau, ob Du die Stringkonvertierung in der Adapterkonfiguration von NodeRed deaktiviert hast - sollte nicht aktiviert sein.

                      Und dann mach eine Debug Node dahin, wo Du willst um zu sehen, ob die Nachrichten dort rauskommen wo erwartet. Wenn Du mit on und off schalten musst, dann musst Du halt in die Change und in die Trigger Node entsprechend on oder off statt true und false eintragen.

                      A 2 Replies Last reply Reply Quote 0
                      • A
                        Andre105 @mickym last edited by Andre105

                        @mickym
                        Ich probiere es mal ohne Schalter.
                        So schaltet er ja schon mal super.
                        Wenn ich den Schalter betätige dann geht es ja auch nach 1 min aus.
                        Muss nur noch sehen ob das morgen mit der Astrofunktion funktioniert.
                        Das er am Tage nicht schaltet.

                        7ba18f27-1015-4b9c-9642-7e9b9f17704c-image.png

                        Ich muss glaube mal ein Node-Red Kurs machen.Gefällt mir ganz gut.
                        Mal schauen ob ich was finde.(Glaube Matthias Kleine hat ein.

                        1 Reply Last reply Reply Quote 0
                        • A
                          Andre105 @mickym last edited by

                          @mickym
                          Am Tage wenn ich in den Raum gehe,dann zuckt die Lampe kurz an,geht aber sofort wieder aus.
                          Nicht so gut für die Lampen denke ich.
                          Kann man da noch was machen?

                          mickym 1 Reply Last reply Reply Quote 0
                          • mickym
                            mickym Most Active @Andre105 last edited by mickym

                            @andre105 mach einfach mal den Ast aus dem unteren Ast der Lightscheduler Node weg. Dann kommt tagsüber gar kein Signal mehr an der Lampe an.

                            Wenn Du über die occupancy timeout auf 60s setzt, bei dem Xiaomi BWM (die liefern auch true und false) bei occupancy dann kannst einfach die Lampe nur oben anschließen. Die Blockade mit dem Schalter würde ich ggf. drin lassen.

                            3c5d7e08-1d99-4097-9efe-2bbacb235219-image.png

                            Also den Switch nur an den oberen Ausgang machen.

                            32215503-bd0f-42ea-93cd-69501ed4b966-image.png

                            A 1 Reply Last reply Reply Quote 0
                            • A
                              Andre105 @mickym last edited by

                              @mickym
                              Wo genau meinst du?

                              4e8cbd21-c5bb-40ed-824c-88d704a53ed8-image.png

                              mickym 1 Reply Last reply Reply Quote 0
                              • mickym
                                mickym Most Active @Andre105 last edited by mickym

                                @andre105 Wie gesagt den Schalter würde ich drin lassen und Shelly Lampe nur an den oberen Ausgang der Lightscheduler Node setzen. Ich hab die doch gerade durchgestrichen.

                                Also so:

                                29096f6a-6d34-424b-9395-18216ab7598a-image.png

                                Da war noch ein Fehler in der switch Schalter Node.

                                [
                                    {
                                        "id": "58180cd0b2b6d731",
                                        "type": "light-scheduler-filter",
                                        "z": "289f539dcc33814e",
                                        "settings": "58906d3dbef01275",
                                        "events": "[{\"start\":{\"dow\":1,\"mod\":0},\"end\":{\"dow\":1,\"mod\":540}},{\"start\":{\"dow\":2,\"mod\":0},\"end\":{\"dow\":2,\"mod\":540}},{\"start\":{\"dow\":3,\"mod\":0},\"end\":{\"dow\":3,\"mod\":540}},{\"start\":{\"dow\":4,\"mod\":0},\"end\":{\"dow\":4,\"mod\":540}},{\"start\":{\"dow\":5,\"mod\":0},\"end\":{\"dow\":5,\"mod\":540}},{\"start\":{\"dow\":6,\"mod\":0},\"end\":{\"dow\":6,\"mod\":540}},{\"start\":{\"dow\":0,\"mod\":0},\"end\":{\"dow\":0,\"mod\":540}},{\"start\":{\"dow\":1,\"mod\":960},\"end\":{\"dow\":2,\"mod\":0}},{\"start\":{\"dow\":2,\"mod\":960},\"end\":{\"dow\":3,\"mod\":0}},{\"start\":{\"dow\":3,\"mod\":960},\"end\":{\"dow\":4,\"mod\":0}},{\"start\":{\"dow\":4,\"mod\":960},\"end\":{\"dow\":5,\"mod\":0}},{\"start\":{\"dow\":5,\"mod\":960},\"end\":{\"dow\":6,\"mod\":0}},{\"start\":{\"dow\":6,\"mod\":960},\"end\":{\"dow\":0,\"mod\":0}},{\"start\":{\"dow\":0,\"mod\":960},\"end\":{\"dow\":1,\"mod\":0}}]",
                                        "name": "Wenn Dunkel",
                                        "onlyWhenDark": true,
                                        "scheduleRndMax": 0,
                                        "sunElevationThreshold": "0",
                                        "sunShowElevationInStatus": true,
                                        "x": 3340,
                                        "y": 2020,
                                        "wires": [
                                            [
                                                "9a1699422e6b3d0c"
                                            ],
                                            []
                                        ]
                                    },
                                    {
                                        "id": "e91f5cf2bc3aa589",
                                        "type": "ioBroker in",
                                        "z": "289f539dcc33814e",
                                        "name": "",
                                        "topic": "BWM1",
                                        "payloadType": "value",
                                        "onlyack": "",
                                        "func": "all",
                                        "gap": "",
                                        "fireOnStart": "false",
                                        "outFormat": "MQTT",
                                        "x": 2790,
                                        "y": 1980,
                                        "wires": [
                                            [
                                                "5671c55a8be9c94e"
                                            ]
                                        ]
                                    },
                                    {
                                        "id": "f2e44a42a3883fca",
                                        "type": "ioBroker in",
                                        "z": "289f539dcc33814e",
                                        "name": "",
                                        "topic": "BWM2",
                                        "payloadType": "value",
                                        "onlyack": "",
                                        "func": "all",
                                        "gap": "",
                                        "fireOnStart": "false",
                                        "outFormat": "MQTT",
                                        "x": 2790,
                                        "y": 2040,
                                        "wires": [
                                            [
                                                "5671c55a8be9c94e"
                                            ]
                                        ]
                                    },
                                    {
                                        "id": "9a1699422e6b3d0c",
                                        "type": "ioBroker out",
                                        "z": "289f539dcc33814e",
                                        "name": "",
                                        "topic": "Lampe",
                                        "ack": "false",
                                        "autoCreate": "false",
                                        "stateName": "",
                                        "role": "",
                                        "payloadType": "",
                                        "readonly": "",
                                        "stateUnit": "",
                                        "stateMin": "",
                                        "stateMax": "",
                                        "x": 3510,
                                        "y": 2020,
                                        "wires": []
                                    },
                                    {
                                        "id": "5671c55a8be9c94e",
                                        "type": "ioBroker get",
                                        "z": "289f539dcc33814e",
                                        "name": "",
                                        "topic": "Schalter",
                                        "attrname": "switch",
                                        "payloadType": "value",
                                        "errOnInvalidState": "nothing",
                                        "x": 2940,
                                        "y": 2020,
                                        "wires": [
                                            [
                                                "23e9b3914494c547"
                                            ]
                                        ]
                                    },
                                    {
                                        "id": "23e9b3914494c547",
                                        "type": "switch",
                                        "z": "289f539dcc33814e",
                                        "name": "Schalter = false?",
                                        "property": "switch",
                                        "propertyType": "msg",
                                        "rules": [
                                            {
                                                "t": "false"
                                            }
                                        ],
                                        "checkall": "true",
                                        "repair": false,
                                        "outputs": 1,
                                        "x": 3130,
                                        "y": 2020,
                                        "wires": [
                                            [
                                                "58180cd0b2b6d731"
                                            ]
                                        ]
                                    },
                                    {
                                        "id": "58906d3dbef01275",
                                        "type": "light-scheduler-settings",
                                        "name": "Köln",
                                        "latitude": "50.9446",
                                        "longitude": "7.0115"
                                    }
                                ]
                                

                                Das muss natürlich übereinstimmen:

                                b84fc783-d59d-4690-a6bc-23c7a080e48d-image.png a78da016-cb73-41b5-839e-24d487edceb5-image.png

                                Hängt halt davon ab, wie der Datenpunkt aussieht, wenn der Schalter ein oder aus ist. Also vielleicht auch on oder off.

                                mickym 1 Reply Last reply Reply Quote 0
                                • mickym
                                  mickym Most Active @mickym last edited by

                                  @mickym Du kannst auch noch eine Filter Node vorne dran machen, dass Du von beiden BWM nicht 2 mal ein Signal bekommst.

                                  aa24dd46-d9e4-4ccf-b3e4-0d159198e60b-image.png

                                  [
                                     {
                                         "id": "58180cd0b2b6d731",
                                         "type": "light-scheduler-filter",
                                         "z": "289f539dcc33814e",
                                         "settings": "58906d3dbef01275",
                                         "events": "[{\"start\":{\"dow\":1,\"mod\":0},\"end\":{\"dow\":1,\"mod\":540}},{\"start\":{\"dow\":2,\"mod\":0},\"end\":{\"dow\":2,\"mod\":540}},{\"start\":{\"dow\":3,\"mod\":0},\"end\":{\"dow\":3,\"mod\":540}},{\"start\":{\"dow\":4,\"mod\":0},\"end\":{\"dow\":4,\"mod\":540}},{\"start\":{\"dow\":5,\"mod\":0},\"end\":{\"dow\":5,\"mod\":540}},{\"start\":{\"dow\":6,\"mod\":0},\"end\":{\"dow\":6,\"mod\":540}},{\"start\":{\"dow\":0,\"mod\":0},\"end\":{\"dow\":0,\"mod\":540}},{\"start\":{\"dow\":1,\"mod\":960},\"end\":{\"dow\":2,\"mod\":0}},{\"start\":{\"dow\":2,\"mod\":960},\"end\":{\"dow\":3,\"mod\":0}},{\"start\":{\"dow\":3,\"mod\":960},\"end\":{\"dow\":4,\"mod\":0}},{\"start\":{\"dow\":4,\"mod\":960},\"end\":{\"dow\":5,\"mod\":0}},{\"start\":{\"dow\":5,\"mod\":960},\"end\":{\"dow\":6,\"mod\":0}},{\"start\":{\"dow\":6,\"mod\":960},\"end\":{\"dow\":0,\"mod\":0}},{\"start\":{\"dow\":0,\"mod\":960},\"end\":{\"dow\":1,\"mod\":0}}]",
                                         "name": "Wenn Dunkel",
                                         "onlyWhenDark": true,
                                         "scheduleRndMax": 0,
                                         "sunElevationThreshold": "0",
                                         "sunShowElevationInStatus": true,
                                         "x": 3540,
                                         "y": 2020,
                                         "wires": [
                                             [
                                                 "9a1699422e6b3d0c"
                                             ],
                                             []
                                         ]
                                     },
                                     {
                                         "id": "e91f5cf2bc3aa589",
                                         "type": "ioBroker in",
                                         "z": "289f539dcc33814e",
                                         "name": "",
                                         "topic": "BWM1",
                                         "payloadType": "value",
                                         "onlyack": "",
                                         "func": "all",
                                         "gap": "",
                                         "fireOnStart": "false",
                                         "outFormat": "MQTT",
                                         "x": 2790,
                                         "y": 1980,
                                         "wires": [
                                             [
                                                 "630c56aa621d8047"
                                             ]
                                         ]
                                     },
                                     {
                                         "id": "f2e44a42a3883fca",
                                         "type": "ioBroker in",
                                         "z": "289f539dcc33814e",
                                         "name": "",
                                         "topic": "BWM2",
                                         "payloadType": "value",
                                         "onlyack": "",
                                         "func": "all",
                                         "gap": "",
                                         "fireOnStart": "false",
                                         "outFormat": "MQTT",
                                         "x": 2790,
                                         "y": 2040,
                                         "wires": [
                                             [
                                                 "630c56aa621d8047"
                                             ]
                                         ]
                                     },
                                     {
                                         "id": "9a1699422e6b3d0c",
                                         "type": "ioBroker out",
                                         "z": "289f539dcc33814e",
                                         "name": "",
                                         "topic": "Lampe",
                                         "ack": "false",
                                         "autoCreate": "false",
                                         "stateName": "",
                                         "role": "",
                                         "payloadType": "",
                                         "readonly": "",
                                         "stateUnit": "",
                                         "stateMin": "",
                                         "stateMax": "",
                                         "x": 3710,
                                         "y": 2020,
                                         "wires": []
                                     },
                                     {
                                         "id": "5671c55a8be9c94e",
                                         "type": "ioBroker get",
                                         "z": "289f539dcc33814e",
                                         "name": "",
                                         "topic": "Schalter",
                                         "attrname": "switch",
                                         "payloadType": "value",
                                         "errOnInvalidState": "nothing",
                                         "x": 3140,
                                         "y": 2020,
                                         "wires": [
                                             [
                                                 "23e9b3914494c547"
                                             ]
                                         ]
                                     },
                                     {
                                         "id": "23e9b3914494c547",
                                         "type": "switch",
                                         "z": "289f539dcc33814e",
                                         "name": "Schalter = false?",
                                         "property": "switch",
                                         "propertyType": "msg",
                                         "rules": [
                                             {
                                                 "t": "false"
                                             }
                                         ],
                                         "checkall": "true",
                                         "repair": false,
                                         "outputs": 1,
                                         "x": 3330,
                                         "y": 2020,
                                         "wires": [
                                             [
                                                 "58180cd0b2b6d731"
                                             ]
                                         ]
                                     },
                                     {
                                         "id": "630c56aa621d8047",
                                         "type": "rbe",
                                         "z": "289f539dcc33814e",
                                         "name": "",
                                         "func": "rbe",
                                         "gap": "",
                                         "start": "",
                                         "inout": "out",
                                         "septopics": false,
                                         "property": "payload",
                                         "topi": "topic",
                                         "x": 2970,
                                         "y": 2020,
                                         "wires": [
                                             [
                                                 "5671c55a8be9c94e"
                                             ]
                                         ]
                                     },
                                     {
                                         "id": "58906d3dbef01275",
                                         "type": "light-scheduler-settings",
                                         "name": "Köln",
                                         "latitude": "50.9446",
                                         "longitude": "7.0115"
                                     }
                                  ]
                                  

                                  A 1 Reply Last reply Reply Quote 0
                                  • A
                                    Andre105 @mickym last edited by Andre105

                                    @mickym

                                    Hab das mal so ausprobiert.
                                    Direkt mal Screenshot

                                    9746062c-396f-4df1-87c3-7445160957e8-image.png

                                    Und jetzt 5min später

                                    e365f4d3-71c7-47e8-bb84-ee440b203af2-image.png

                                    Licht geht nach 60s aus.
                                    Auch wenn ich das Licht mit Schalter an mache,geht es nach 60s aus.
                                    Schon mal gut.

                                    Warum jetzt beim Shelly der Lampe immer noch true steht weiß ich nicht,Licht ist aber aus.

                                    In den Nodes steht auch beides switch.

                                    mickym 1 Reply Last reply Reply Quote 0
                                    • mickym
                                      mickym Most Active @Andre105 last edited by mickym

                                      @andre105 Na wenn da true drin steht - dann steht der Datenpunkt den Du ausliest auf true - dann sollte nichts hinten rauskommen. Du musst halt mit Debug Nodes testen, ob was rauskommt oder nicht. True ist ja richtig wenn der Schalter an ist. Dann sollte das Licht aber nicht ausgehen.

                                      Schau nochmal in Deine Adapterkonfiguration - ob Du nicht doch die dumme Konvertierung drin hast:

                                      Das muss aus sein:

                                      393f3e58-67aa-4167-b438-c6292017eaf9-image.png

                                      sonst kannst diese Logiken alle vergessen bzw. musst alles mit Strings vergleichen.

                                      A 1 Reply Last reply Reply Quote 0
                                      • A
                                        Andre105 @mickym last edited by

                                        @mickym

                                        Das ist jetzt der Datenpunkt vom Shelly

                                        5e5064fe-c3b8-48a2-a1df-00501b39a830-image.png

                                        Hier steht false.
                                        Deswegen wunder ich mich das da true steht.

                                        Einfach eine Debug Node hinter der iobroker Get ranhängen?

                                        mickym 1 Reply Last reply Reply Quote 0
                                        • mickym
                                          mickym Most Active @Andre105 last edited by mickym

                                          @andre105 Nein die Debug Node nach dem Switch - schau bitte in die Adapterkonfig wie gepostet. Nach dem Switch siehst Du ja erst, ob die Nachricht blockiert wird, wenn der Schalter an ist oder nicht.

                                          A 1 Reply Last reply Reply Quote 0
                                          • A
                                            Andre105 @mickym last edited by

                                            @mickym

                                            72c202ac-8931-4c7b-a193-03fe5d6a642b-image.png

                                            mickym 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            1.1k
                                            Online

                                            31.7k
                                            Users

                                            79.7k
                                            Topics

                                            1.3m
                                            Posts

                                            3
                                            216
                                            14994
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo