    Alpha Testing: OCPP Wallbox Adapter

    This topic has been deleted. Only users with topic management privileges can see it.
    • F
      frank11 last edited by

      @foxriver76 said in Alpha Testing: OCPP Wallbox Adapter:

      chargingScheduleAllowedChargingRateUnit

      Leider nicht. 😞
      Oben im Screenshot war die komplette Liste.

      1 Reply Last reply Reply Quote 0
      • foxriver76
        foxriver76 Developer @foxriver76 last edited by

        Standards 💩
        Lt. OCPP Standard sollte der Config Punkt bereitgestellt werden, wenn Smart Charging unterstützt wird. Wirkt bei der etwas mau, dafür dass 5 Profile unterstützt sind.

        @foxriver76 sagte in Alpha Testing: OCPP Wallbox Adapter:

        Dann solltest du im Connector (Channel 1) auch chargeLimitType entsprechend einstellen und kannst dann hoffentlich mit chargeLimit die Ladeleistung verändern.

        Hast du das trotzdem mal probiert @frank11?

        F 1 Reply Last reply Reply Quote 0
        • F
          frank11 @foxriver76 last edited by

          @foxriver76
          Korrekt, jetzt sehe ich den Datenpunkt:

          Bildschirm­foto 2023-01-17 um 14.11.39.png

          Bin noch ioBroker-Anfänger, ich musste erstmal schauen, wie ich neue Werte anlegen kann 😬

          Jetzt kann ich mir praktisch im ioBroker Seiten erstellen, mit denen ich das testen kann bevor es automatisiert wird, richtig?

          foxriver76 1 Reply Last reply Reply Quote 0
          • foxriver76
            foxriver76 Developer @frank11 last edited by

            @frank11 Mit Seiten meinst du eine graphische Oberfläche?

            Zum Testen kannst du auch hinten bei (null) A klicken und einen Wert eintragen. Über transactionActive kann man bei den meisten WBs direkt einen Ladevorgang starten. Ob die Änderung des Limits funktioniert, kann man vermutlich am ehesten mit der App des Autos oder im Display des Autos prüfen. Evtl. sagt er auch dass es einen Fehler gibt im Log (Tab Protokoll).

            1 Reply Last reply Reply Quote 0
            • F
              frank11 last edited by

              @foxriver76

              Ja, genau. Eine GUI.

              Das hat aber geklappt, oder? Das Objekt wurde ja erstellt.

              Bildschirm­foto 2023-01-17 um 14.26.22.png

              Sonst gab es keine Fehler. Ich habe jetzt mal 6A gesetzt.

              foxriver76 1 Reply Last reply Reply Quote 0
              • foxriver76
                foxriver76 Developer @frank11 last edited by

                @frank11 Hm also entweder habe ich da noch einen Bug oder irgendwas anderes stimmt nicht. Kannst du mal ein Screenshot zeigen vom chargeLimit und den darüberliegenden States.

                F 1 Reply Last reply Reply Quote 0
                • F
                  frank11 @foxriver76 last edited by

                  @foxriver76

                  Bildschirm­foto 2023-01-17 um 14.56.42.png

                  foxriver76 1 Reply Last reply Reply Quote 0
                  • foxriver76
                    foxriver76 Developer @frank11 last edited by

                    @frank11 danke, ja schaut gut aus.

                    Ah.. bitte keine Datenpunkte in Adaptern manuell erzeugen, den chargeLimitType bitte wieder löschen aus der configuration und den Channel NaN entsprechend auch löschen, ansonsten schaut das gut aus.

                    1 Reply Last reply Reply Quote 0
                    • F
                      fL4sH 0 @foxriver76 last edited by fL4sH 0

                      @foxriver76
                      Moin, hier ist ein Auszug von den idTags die der ioBroker schreibt und von meinen RFID-Chips. Das funktioniert schon mal einwandfrei.

                      365a37c9-adce-4989-952a-37afadc2a2cd-image.png

                      Ich habe nur noch einen Fehler festgestellt. Bei der Ladung über einen RFID-Chip, ist es komischerweise egal ob der RFID-Chip in der Box registriert ist oder nicht. Man kann die Transaktion mit allen RFID-Chips starten und die Ladung beginnt. Obwohl in der Wallbox nur ein RFID-Chip autorisiert ist. Liegt das an der Wallbox selber oder wird die Autorisierung nicht geprüft ?

                      1d671c30-dcde-45ea-8980-ed8d15d55a77-image.png

                      Das sind die beiden RFID-Chips die nicht in der Wallbox hinterlegt sind.

                      Vom Prinzip müsste die Logik ja sein das der idTag (RFID-Chip) der die Transaktion startet, diesen auch nur beenden kann.
                      Jetzt könnte die Ladung auch von jemand fremden gestoppt werden!

                      F foxriver76 2 Replies Last reply Reply Quote 0
                      • F
                        fL4sH 0 @fL4sH 0 last edited by fL4sH 0

                        @foxriver76
                        Seid der neuen Version 0.11.1 kommen häufiger die Warnung das die Transaktion von der Ladesäule abgelehnt wird.

                        e575978f-81d8-4fce-af89-c5641aaa9bac-image.png

                        Anscheinend kommt dieser Fehler nur wenn man eine Transaktion startet und das Chargelimit vorher gesetzt wurde.

                        foxriver76 1 Reply Last reply Reply Quote 0
                        • foxriver76
                          foxriver76 Developer @fL4sH 0 last edited by

                          @fl4sh-0 Gibt es beim beenden des Vorgangs auch eine Warnung, dass er in ein nicht existierendes Objekt schreibt? Ich hatte letztens, dass die WB beim Start die Verbindung verloren hat und sich eine eigene Transaktions-ID festgelegt hat und dann kennt der Adapter diese nicht und kann die Transaktion nicht stoppen.

                          F 1 Reply Last reply Reply Quote 0
                          • F
                            fL4sH 0 @foxriver76 last edited by

                            @foxriver76 Beim Beenden des Vorgangs kommt keine Warnung, dass er in ein nicht existierendes Objekt schreibt.
                            Die beiden Warnungen kommen lediglich wenn transactionActive=true und Chargelimit=6A vorher gesetzt wurde.
                            Dann kommt die Warnung.

                            Starting transaction has been rejected by charge point
                            

                            Wenn ich anschließend transactionActive=false setze und Chargelimit=6A immer noch gesetzt ist.

                            Dann kommt diese Warnung.

                            Stopping transaction has been rejected by charge point
                            

                            Wenn das Charglimit=0A kann die Transaktion ganz normal gestartet und gestoppt werden.

                            F 1 Reply Last reply Reply Quote 0
                            • F
                              fL4sH 0 @fL4sH 0 last edited by fL4sH 0

                              @foxriver76 Was mir noch aufgefallen ist, dass die MeterValues nach der Beendigung des Ladevorgangs einfrieren bzw. nicht mehr aktualisiert werden Die Daten werden erst aktualisiert werden wenn man den Adapter neu startet oder eine neue Transaktion beginnt. Ist dieses Verhalten normal ? Besteht die Möglichkeit das die MeterValues nach dem Beenden eines Ladevorgangs nochmal abgeholt werden ?

                              8fffd335-2357-47bb-af2a-35d820df3554-image.png

                              foxriver76 1 Reply Last reply Reply Quote 0
                              • foxriver76
                                foxriver76 Developer @fL4sH 0 last edited by

                                @fl4sh-0 im configuration channel gibt es Werte um das Intervall festzulegen in dem die WB sendet. Im Intervall ClockAlignedDataInterval (Sekunden) werden alle Werte aus MeterValuesAlignedData gesendet.

                                Hier evtl. auch mal checken was in ChargingScheduleAllowedChargingRateUnit steht.

                                F 2 Replies Last reply Reply Quote 0
                                • F
                                  fL4sH 0 @foxriver76 last edited by

                                  @foxriver76 Ok, das werde ich mal prüfen.

                                  Die Änderung vom idTag sieht gut aus.
                                  4682686d-21ff-4b8b-9c6f-0fc62595483a-image.png

                                  1 Reply Last reply Reply Quote 0
                                  • F
                                    fL4sH 0 @foxriver76 last edited by

                                    @foxriver76 said in Alpha Testing: OCPP Wallbox Adapter:

                                    @fl4sh-0 im configuration channel gibt es Werte um das Intervall festzulegen in dem die WB sendet. Im Intervall ClockAlignedDataInterval (Sekunden) werden alle Werte aus MeterValuesAlignedData gesendet.

                                    Hier evtl. auch mal checken was in ChargingScheduleAllowedChargingRateUnit steht.

                                    Hier mal die drei Werte.
                                    ddc2f292-2f69-463f-a6e1-2e18def0b7ea-image.png
                                    d373a50f-7b2e-466e-9c8a-d6994cc7b5a7-image.png
                                    e493f6e9-3050-4613-9c01-762e8ac985f6-image.png

                                    Editierbar ist ClockAlignedDataInterval Wenn ich dort 55 Sek. eintrage aktualisiert er mir nur den Wert
                                    0a5c54b8-96ca-46a6-9c7b-85989ea718fb-image.png und der ist meiner Meinung nach auch falsch.

                                    foxriver76 1 Reply Last reply Reply Quote 0
                                    • foxriver76
                                      foxriver76 Developer @fL4sH 0 last edited by foxriver76

                                      @fl4sh-0 Schau mal in MeterValuesSampledData sind die Datenpunkte die während einer Transaktion alle MeterValueSampleInterval Sekunden übertragen werden. Ohne aktive Transaktion werden wie vorher erwähnt alle ClockAlignedDataInterval Sekunden die Werte aus MeterValuesAlignedData übertragen, wenn du da die gleichen Werte haben möchtest, schreib den Inhalt von MeterValuesSampledData auch in MeterValuesAlignedData.

                                      Warum der Wert falsch ist, kann ich aktuell nichts zu sagen.

                                      F 1 Reply Last reply Reply Quote 0
                                      • F
                                        fL4sH 0 @foxriver76 last edited by fL4sH 0

                                        @foxriver76

                                        Wenn ich genau die gleich Werte wie in der MeterValuesSampledData eintrage, steht im Log Cannot change.....
                                        Wenn ich mich auf 4 Werte beschränke, funktioniert die Aktualisierung zwar aber nur auf "Oberster Ebene"

                                        a7a27308-14d4-47fd-996c-90589908c5a9-image.png

                                        ocpp.0 2023-01-18 11:20:40.322	debug	{"connectorId":1,"meterValue":[{"timestamp":"2023-01-18T10:20:40.000Z","sampledValue":[{"value":"0.0","context":"Sample.Clock","format":"Raw","measurand":"Current.Import","location":"Inlet"},{"value":"6","context":"Sample.Clock","format":"Raw","measurand":"Current.Offered","location":"Inlet"},{"value":"1284601","context":"Sample.Clock","format":"Raw","measurand":"Energy.Active.Import.Register","location":"Inlet"},{"value":"0","context":"Sample.Clock","format":"Raw","measurand":"Power.Active.Import","location":"Inlet"}]}],"commandOcpp":"MeterValues"}
                                        ocpp.0 2023-01-18 11:20:17.839	info	Changing configuration (device: /TACW1142021G1020) of "MeterValuesAlignedData" to "Current.Import,Current.Offered,Energy.Active.Import.Register,Power.Active.Import"
                                        ocpp.0 2023-01-18 11:20:00.276	info	Received MeterValues from "/TACW1142021G1020.1"
                                        ocpp.0 2023-01-18 11:20:00.276	debug	{"connectorId":1,"meterValue":[{"timestamp":"2023-01-18T10:20:00.000Z","sampledValue":[{"value":"1284601","context":"Sample.Clock","format":"Raw","measurand":"Energy.Active.Import.Register","location":"Inlet"},{"value":"0","context":"Sample.Clock","format":"Raw","measurand":"Power.Active.Import","location":"Inlet"},{"value":"2269","context":"Sample.Clock","format":"Raw","measurand":"Voltage","location":"Inlet"}]}],"commandOcpp":"MeterValues"}
                                        ocpp.0 2023-01-18 11:19:46.662	debug	Received heartbeat from "/TACW1142021G1020"
                                        ocpp.0 2023-01-18 11:19:46.661	debug	{"commandOcpp":"Heartbeat"}
                                        ocpp.0 2023-01-18 11:19:43.338	warn	Cannot change confiuration of /TACW1142021G1020 (key: MeterValuesAlignedData, value: Current.Import,Current.Offered,Energy.Active.Import.Register,Power.Active.Import,Voltage): Rejected
                                        

                                        7fcda12c-a045-4301-b2b0-8157e4ddad43-image.png
                                        Dieser Wert ist der Gesamtzähler der Wallbox sein.

                                        foxriver76 1 Reply Last reply Reply Quote 0
                                        • F
                                          frank11 last edited by

                                          Ich habe gerade irgendwas von RFID gelesen.

                                          Ich lade im Moment nur ein Auto mit RFID-Karte als Authentifizierung.
                                          Da kann man auslesen, mit welcher Karte geladen wurde?

                                          Dann könnte das zweite BEV kommen.

                                          foxriver76 1 Reply Last reply Reply Quote 0
                                          • foxriver76
                                            foxriver76 Developer @fL4sH 0 last edited by

                                            @fl4sh-0 Es gibt noch MeterValuesAlignedDataMaxLength und das gleiche für MeterValuesSampledDataMaxLength evtl. lässt sampled Data mehr Punkte zu als aligned data?

                                            F 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            478
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts