    Einrichten Modbus Adapter / Solar X3 Gen4

    This topic has been deleted. Only users with topic management privileges can see it.
    • McWoolf
      McWoolf @wendy2702 last edited by

      @wendy2702
      Alles klar werde ich dann gleich mal versuchen. Der Port 8081 ist vom ioBroker. Dachte da müsste man den Port für die Gegenseite eintragen.

      wendy2702 1 Reply Last reply Reply Quote 0
      • wendy2702
        wendy2702 @McWoolf last edited by

        @mcwoolf Port 8081 ist für den Admin, nicht für Modbus.

        McWoolf 1 Reply Last reply Reply Quote 0
        • McWoolf
          McWoolf @wendy2702 last edited by

          @wendy2702 wenn ich aber einen anderen Port nehme, habe ich gar keine Kommunikation mehr.

          McWoolf 1 Reply Last reply Reply Quote 0
          • McWoolf
            McWoolf @McWoolf last edited by

            @mcwoolf sagte in Einrichten Modbus Adapter / Solar X3 Gen4:

            @wendy2702 wenn ich aber einen anderen Port nehme, habe ich gar keine Kommunikation mehr.

            3f9101d0-d790-4d80-9fea-530ce040b8e9-image.png

            Mit dieser Einstellung zählt wenigstens der TX Count

            070eb73a-790e-4344-bace-1bc18a6377b3-image.png

            wendy2702 1 Reply Last reply Reply Quote 0
            • wendy2702
              wendy2702 @McWoolf last edited by wendy2702

              @mcwoolf Was ist mit den Adapter/Register einstellungen?

              Welches Device hat welche Adresse?

              Ws kommt im Debug log vom Adapter?

              McWoolf 1 Reply Last reply Reply Quote 0
              • McWoolf
                McWoolf @wendy2702 last edited by

                @wendy2702
                Also:

                USR 192.168.1.246
                IOB 192.168.1.250
                WR 192.168.1.245 (Lan-Dongle)

                Device ID im SolaxWR habe ich mal auf 2 gestellt, zum testen

                McWoolf 1 Reply Last reply Reply Quote 0
                • McWoolf
                  McWoolf @McWoolf last edited by

                  @mcwoolf sagte in Einrichten Modbus Adapter / Solar X3 Gen4:

                  @wendy2702
                  Also:

                  USR 192.168.1.246
                  IOB 192.168.1.250
                  WR 192.168.1.245 (Lan-Dongle)

                  Device ID im SolaxWR habe ich mal auf 2 gestellt, zum testen

                  2023-01-18 08:47:04.364 - info: shelly.0 (2744968) [MQTT] Device 192.168.30.41 (shellyht / shellyht-024F7E / SHHT-1#024F7E#1) connected! Polltime set to 5 sec.
                  2023-01-18 08:47:10.460 - info: modbus.0 (2274495) Got terminate signal TERMINATE_YOURSELF
                  2023-01-18 08:47:10.460 - info: modbus.0 (2274495) terminating
                  2023-01-18 08:47:10.461 - info: modbus.0 (2274495) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                  2023-01-18 08:47:13.697 - debug: modbus.0 (2274856) Redis Objects: Use Redis connection: 127.0.0.1:9001
                  2023-01-18 08:47:13.718 - debug: modbus.0 (2274856) Objects client ready ... initialize now
                  2023-01-18 08:47:13.718 - debug: modbus.0 (2274856) Objects create System PubSub Client
                  2023-01-18 08:47:13.719 - debug: modbus.0 (2274856) Objects create User PubSub Client
                  2023-01-18 08:47:13.746 - debug: modbus.0 (2274856) Objects client initialize lua scripts
                  2023-01-18 08:47:13.747 - debug: modbus.0 (2274856) Objects connected to redis: 127.0.0.1:9001
                  2023-01-18 08:47:13.807 - debug: modbus.0 (2274856) Redis States: Use Redis connection: 127.0.0.1:9000
                  2023-01-18 08:47:13.815 - debug: modbus.0 (2274856) States create System PubSub Client
                  2023-01-18 08:47:13.815 - debug: modbus.0 (2274856) States create User PubSub Client
                  2023-01-18 08:47:13.872 - debug: modbus.0 (2274856) States connected to redis: 127.0.0.1:9000
                  2023-01-18 08:47:13.926 - debug: modbus.0 (2274856) Plugin sentry Initialize Plugin (enabled=true)
                  2023-01-18 08:47:13.996 - info: modbus.0 (2274856) starting. Version 5.0.11 in /opt/iobroker/node_modules/iobroker.modbus, node: v16.19.0, js-controller: 4.0.24
                  2023-01-18 08:47:14.065 - debug: modbus.0 (2274856) Initialize Objects for disInputs: []
                  2023-01-18 08:47:14.065 - debug: modbus.0 (2274856) Initialize Objects for coils: []
                  2023-01-18 08:47:14.065 - debug: modbus.0 (2274856) Initialize Objects for inputRegs: []
                  2023-01-18 08:47:14.065 - debug: modbus.0 (2274856) Initialize Objects for holdingRegs: [{"_address":0,"deviceId":2,"name":"Seriennummer","description":"","unit":"","type":"string","len":7,"factor":1,"offset":0,"formula":"","role":"level","room":"","poll":true,"wp":"","cw":"","isScale":"","address":0,"id":"holdingRegisters.0_Seriennummer"}]
                  2023-01-18 08:47:14.065 - debug: modbus.0 (2274856) Add holdingRegisters.0_Seriennummer: {"_id":"holdingRegisters.0_Seriennummer","type":"state","common":{"name":"","role":"level","type":"string","read":true,"write":true,"def":"","unit":""},"native":{"regType":"holdingRegs","address":0,"deviceId":2,"type":"string","len":7,"offset":0,"factor":1,"poll":true}}
                  2023-01-18 08:47:14.168 - error: modbus.0 (2274856) Socket Error
                  2023-01-18 08:47:14.168 - error: modbus.0 (2274856) Client in error state.
                  2023-01-18 08:47:14.168 - warn: modbus.0 (2274856) On error: {"errno":-111,"code":"ECONNREFUSED","syscall":"connect","address":"192.168.1.246","port":502}
                  2023-01-18 08:47:14.168 - debug: modbus.0 (2274856) Socket closed with error
                  2023-01-18 08:47:14.169 - debug: modbus.0 (2274856) Cleaning up request fifo.
                  2023-01-18 08:47:15.169 - debug: modbus.0 (2274856) Closing client on purpose.
                  
                  McWoolf 1 Reply Last reply Reply Quote 0
                  • McWoolf
                    McWoolf @McWoolf last edited by

                    @mcwoolf sagte in Einrichten Modbus Adapter / Solar X3 Gen4:

                    @mcwoolf sagte in Einrichten Modbus Adapter / Solar X3 Gen4:

                    @wendy2702
                    Also:

                    USR 192.168.1.246
                    IOB 192.168.1.250
                    WR 192.168.1.245 (Lan-Dongle)

                    Device ID im SolaxWR habe ich mal auf 2 gestellt, zum testen

                    2023-01-18 08:47:04.364 - info: shelly.0 (2744968) [MQTT] Device 192.168.30.41 (shellyht / shellyht-024F7E / SHHT-1#024F7E#1) connected! Polltime set to 5 sec.
                    2023-01-18 08:47:10.460 - info: modbus.0 (2274495) Got terminate signal TERMINATE_YOURSELF
                    2023-01-18 08:47:10.460 - info: modbus.0 (2274495) terminating
                    2023-01-18 08:47:10.461 - info: modbus.0 (2274495) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                    2023-01-18 08:47:13.697 - debug: modbus.0 (2274856) Redis Objects: Use Redis connection: 127.0.0.1:9001
                    2023-01-18 08:47:13.718 - debug: modbus.0 (2274856) Objects client ready ... initialize now
                    2023-01-18 08:47:13.718 - debug: modbus.0 (2274856) Objects create System PubSub Client
                    2023-01-18 08:47:13.719 - debug: modbus.0 (2274856) Objects create User PubSub Client
                    2023-01-18 08:47:13.746 - debug: modbus.0 (2274856) Objects client initialize lua scripts
                    2023-01-18 08:47:13.747 - debug: modbus.0 (2274856) Objects connected to redis: 127.0.0.1:9001
                    2023-01-18 08:47:13.807 - debug: modbus.0 (2274856) Redis States: Use Redis connection: 127.0.0.1:9000
                    2023-01-18 08:47:13.815 - debug: modbus.0 (2274856) States create System PubSub Client
                    2023-01-18 08:47:13.815 - debug: modbus.0 (2274856) States create User PubSub Client
                    2023-01-18 08:47:13.872 - debug: modbus.0 (2274856) States connected to redis: 127.0.0.1:9000
                    2023-01-18 08:47:13.926 - debug: modbus.0 (2274856) Plugin sentry Initialize Plugin (enabled=true)
                    2023-01-18 08:47:13.996 - info: modbus.0 (2274856) starting. Version 5.0.11 in /opt/iobroker/node_modules/iobroker.modbus, node: v16.19.0, js-controller: 4.0.24
                    2023-01-18 08:47:14.065 - debug: modbus.0 (2274856) Initialize Objects for disInputs: []
                    2023-01-18 08:47:14.065 - debug: modbus.0 (2274856) Initialize Objects for coils: []
                    2023-01-18 08:47:14.065 - debug: modbus.0 (2274856) Initialize Objects for inputRegs: []
                    2023-01-18 08:47:14.065 - debug: modbus.0 (2274856) Initialize Objects for holdingRegs: [{"_address":0,"deviceId":2,"name":"Seriennummer","description":"","unit":"","type":"string","len":7,"factor":1,"offset":0,"formula":"","role":"level","room":"","poll":true,"wp":"","cw":"","isScale":"","address":0,"id":"holdingRegisters.0_Seriennummer"}]
                    2023-01-18 08:47:14.065 - debug: modbus.0 (2274856) Add holdingRegisters.0_Seriennummer: {"_id":"holdingRegisters.0_Seriennummer","type":"state","common":{"name":"","role":"level","type":"string","read":true,"write":true,"def":"","unit":""},"native":{"regType":"holdingRegs","address":0,"deviceId":2,"type":"string","len":7,"offset":0,"factor":1,"poll":true}}
                    2023-01-18 08:47:14.168 - error: modbus.0 (2274856) Socket Error
                    2023-01-18 08:47:14.168 - error: modbus.0 (2274856) Client in error state.
                    2023-01-18 08:47:14.168 - warn: modbus.0 (2274856) On error: {"errno":-111,"code":"ECONNREFUSED","syscall":"connect","address":"192.168.1.246","port":502}
                    2023-01-18 08:47:14.168 - debug: modbus.0 (2274856) Socket closed with error
                    2023-01-18 08:47:14.169 - debug: modbus.0 (2274856) Cleaning up request fifo.
                    2023-01-18 08:47:15.169 - debug: modbus.0 (2274856) Closing client on purpose.
                    

                    Der zählt übrigens auch, wenn der modbus-Adapter aus ist.

                    wendy2702 1 Reply Last reply Reply Quote 0
                    • wendy2702
                      wendy2702 last edited by

                      @mcwoolf

                      Ich kenne den WR nicht aber wie sieht der Physikalische Aufbau aus?

                      Das USR RS485 ist mit dem WR bereits verbunden denke ich.

                      Wie lauten die Modbus einstellungen im WR? Baudrate, Parität, ID usw.

                      Bitte Screenshot der Adapter Einstellungen und Register.

                      McWoolf 1 Reply Last reply Reply Quote 0
                      • wendy2702
                        wendy2702 @McWoolf last edited by

                        @mcwoolf sagte in Einrichten Modbus Adapter / Solar X3 Gen4:

                        Der zählt übrigens auch, wenn der modbus-Adapter aus ist.

                        Ja, weil er einfach nur RX/TX Pakete zählt.

                        1 Reply Last reply Reply Quote 0
                        • McWoolf
                          McWoolf @wendy2702 last edited by

                          @wendy2702
                          f1ab83be-1968-4472-b131-12b613a71ec8-image.png
                          08d38c05-2ae8-4677-ad31-5bbe9b015711-image.png

                          wendy2702 1 Reply Last reply Reply Quote 0
                          • wendy2702
                            wendy2702 @McWoolf last edited by wendy2702

                            @mcwoolf Haken bei "Direkte ...." raus.

                            Als Test Register mal Spannung oder Temperatur nehmen.

                            Sicher das es ein Holding Register und kein Input Register ist?

                            Stimmt die ID 2 mit dem was im WR steht überein?

                            McWoolf 1 Reply Last reply Reply Quote 0
                            • McWoolf
                              McWoolf @wendy2702 last edited by

                              @wendy2702
                              73b590b7-5d3b-48f6-9909-e8ad67c2a79a-image.png

                              Sowas z.B. ?

                              wendy2702 1 Reply Last reply Reply Quote 0
                              • wendy2702
                                wendy2702 @McWoolf last edited by

                                @mcwoolf Ja.

                                unter Eingangsregister als 16bit, denke auch little endian wobei mit bei der Register Adresse die 0 etwas wundert.

                                McWoolf 1 Reply Last reply Reply Quote 0
                                • McWoolf
                                  McWoolf @wendy2702 last edited by

                                  @wendy2702
                                  Das ist die offizielle Beschreibung

                                  McWoolf 1 Reply Last reply Reply Quote 0
                                  • McWoolf
                                    McWoolf @McWoolf last edited by

                                    @mcwoolf
                                    Mit Hilfe von @klassisch habe ich endlich eine Verbindung herstellen können. Hier die Einstellungen:
                                    8e52a5e2-db3c-4d3e-a174-271866743aae-image.png d028ffb4-f543-410a-b472-cdbc40b135d4-image.png

                                    wendy2702 1 Reply Last reply Reply Quote 0
                                    • wendy2702
                                      wendy2702 @McWoolf last edited by

                                      @mcwoolf habt ihr das per Chat gemacht oder gibt es einen weiteren thread?

                                      McWoolf 1 Reply Last reply Reply Quote 0
                                      • McWoolf
                                        McWoolf @wendy2702 last edited by

                                        @wendy2702 Er hat mir per chat geholfen.
                                        Aber ich bekomme noch keine passenden Daten, ich komme mit den Registern noch nicht klar

                                        McWoolf 1 Reply Last reply Reply Quote 0
                                        • McWoolf
                                          McWoolf @McWoolf last edited by

                                          @mcwoolf Ich muss leider alles revidieren, der USR-TCP232-304 kann kein RTU!!!!

                                          Kein wunder dass ich keine Daten bekomme.

                                          wendy2702 K 2 Replies Last reply Reply Quote 0
                                          • wendy2702
                                            wendy2702 @McWoolf last edited by

                                            @mcwoolf OK.

                                            Vielleicht ist das was für dich.

                                            https://eckstein-shop.de/WaveShare-Industrial-Serial-Server-with-POE

                                            Gibt es für einen euro weniger auch ohne POE. Den verwende ich und ich glaube @klassisch auch.

                                            McWoolf 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate
                                            FAQ Cloud / IOT
                                            HowTo: Node.js-Update
                                            HowTo: Backup/Restore
                                            Downloads
                                            BLOG

                                            635
                                            Online

                                            31.6k
                                            Users

                                            79.5k
                                            Topics

                                            1.3m
                                            Posts

                                            19
                                            147
                                            12317
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo