      modbus.1
      	2023-01-25 20:56:37.028	info	Connected to slave
      modbus.1
      	2023-01-25 20:55:37.020	info	Disconnected from slave
      modbus.1
      	2023-01-25 20:55:36.021	warn	Poll error count: 1 code: {"err":"timeout","timeout":500}
      modbus.1
      	2023-01-25 20:55:36.019	error	Request timed out.
      modbus.1
      	2023-01-25 20:55:36.018	warn	Error: undefined
      modbus.1
      	2023-01-25 20:55:35.590	error	Wrong CRC for frame: 1,4,12,0,3,20,171,0,78,0,99,0,94,0,40,219,140
      modbus.1
      	2023-01-25 20:54:21.697	info	Connected to slave
      modbus.1
      	2023-01-25 20:53:21.685	info	Disconnected from slave
      modbus.1
      	2023-01-25 20:53:20.683	warn	Poll error count: 1 code: {"err":"timeout","timeout":500}
      modbus.1
      	2023-01-25 20:53:20.681	error	Request timed out.
      modbus.1
      	2023-01-25 20:53:20.679	warn	Error: undefined
      modbus.1
      	2023-01-25 20:53:20.250	error	Wrong CRC for frame: 1,4,4,0,3,20,130,0,206
      modbus.1
      	2023-01-25 20:53:00.639	info	Connected to slave
      

      jetzt hab i dauernde reconnects... 😞

      wendy2702 1 Reply Last reply Reply Quote 0
      • wendy2702
        wendy2702 @michael.pusch last edited by wendy2702

        @michael-pusch WIe sehen denn die Register aus?

        Funktioniert es wieder wenn du den haken wieder setzt?

        Und, das ist kein DEBUG log!!!

        michael.pusch Glasfaser 2 Replies Last reply Reply Quote 0
        • michael.pusch
          michael.pusch @wendy2702 last edited by michael.pusch

          @wendy2702

          hab den modbus.1 ausgewählt und auf debug gestellt...

          DAS sind die daten die ich krieg.
          Screenshot 2023-01-25 210108.png

          Screenshot 2023-01-25 210025.png

          momentan rennts... zumindest kommen daten rein... frage is nur wie lange...

          DER adpater war aber eigentlich nicht mein Problem...
          Hier les ich nur daten aus der Batterie aus.

          Modbus.0 is der Hybridwechselrichter und da möcht ich daten schreiben können. Das sollte laut Hersteller auch funktionieren.
          Unter Holdingregister kann ich den Parameter auslesen, aber ned schreiben... da krieg ich dann eben den Slave Fehler...

          Screenshot 2023-01-25 210738.png

          wendy2702 1 Reply Last reply Reply Quote 0
          • Glasfaser
            Glasfaser @wendy2702 last edited by Glasfaser

            @wendy2702

            Hi .. ...
            gerade mal getestet ...

            ist mir noch gar nicht aufgefallen , da ich selber nur TCP nutze ., dort geht die Umstellung Master / Slave

            Bei Serial und RTU over TCP ist keine Auswahl möglich .

            michael.pusch 1 Reply Last reply Reply Quote 0
            • wendy2702
              wendy2702 @michael.pusch last edited by

              @michael-pusch LOgs bitte immer als Text in Code Tags </> Posten.

              Und du bist sicher das du zum auslesen Eingangsregister verwenden musst?

              Und greift die Instanz 1 auch noch auf den richtigen USB Port zu ?

              michael.pusch 1 Reply Last reply Reply Quote 0
              • michael.pusch
                michael.pusch @Glasfaser last edited by

                @glasfaser
                @wendy2702

                Haaa... ok ?
                is das so gewollt? denn dann kann ich das so nicht nutzen und auch den Parameter ned ändern...

                1 Reply Last reply Reply Quote 0
                • michael.pusch
                  michael.pusch @wendy2702 last edited by michael.pusch

                  @wendy2702 sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                  @michael-pusch LOgs bitte immer als Text in Code Tags </> Posten.

                  Und du bist sicher das du zum auslesen Eingangsregister verwenden musst?

                  Und greift die Instanz 1 auch noch auf den richtigen USB Port zu ?

                  Sorry, war a ausreisser mit dem Snapshotprogramm weil i grad andere bilder gemacht hab... die vorigen codes sind ja im editor... sorry
                  Zum auslesen sind die adressen alle im eingangsregister und das funktioniert auch... der lesend/schreibende sollte ein holdingregister sein und lesen kann ich den auch, aber schreiben ned

                  Screenshot 2023-01-25 211410.png

                  wendy2702 1 Reply Last reply Reply Quote 0
                  • wendy2702
                    wendy2702 @michael.pusch last edited by wendy2702

                    @michael-pusch Was kommt denn im Debug log wenn du versuchst zu schreiben?

                    michael.pusch 1 Reply Last reply Reply Quote 0
                    • michael.pusch
                      michael.pusch @wendy2702 last edited by michael.pusch

                      @wendy2702

                      modbus.0 2023-01-25 21:15:42.174	info	        Disconnected from slave
                      modbus.0 2023-01-25 21:15:41.522	warn	Poll error count: 1 code: "App Timeout"
                      modbus.0 2023-01-25 21:15:41.170	error	Cannot write single register [38407]: {"err":"timeout","timeout":5000}
                      modbus.0 2023-01-25 21:15:41.169	error	Request timed out.
                      modbus.0 2023-01-25 21:15:41.169	warn	Error: undefined
                      modbus.0 2023-01-25 21:15:36.217	error	Error response: Function code received in the query is not recognized or allowed by slave
                      modbus.0 2023-01-25 21:15:36.216	error	Error response for FCx6: Illegal Function
                      admin.0 2023-01-25 21:15:21.307	info	<== Disconnect system.user.admin from ::ffff:192.168.1.112 modbus
                      modbus.1 2023-01-25 21:11:57.222	info	        Connected to slave
                      
                      Homoran wendy2702 2 Replies Last reply Reply Quote 0
                      • Homoran
                        Homoran Global Moderator Administrators @michael.pusch last edited by

                        @michael-pusch das ist kein debug-log!

                        hast du die Instanz auf Logstufe debug gestellt?

                        michael.pusch 1 Reply Last reply Reply Quote 0
                        • wendy2702
                          wendy2702 @michael.pusch last edited by

                          @michael-pusch sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                          Function code received in the query is not recognized or allowed by slave

                          Da steht aber das dein WR den Function Code nicht akzeptiert.

                          Also entweder register falsch, kein Holding, oder falsche Register Parameter.

                          michael.pusch 1 Reply Last reply Reply Quote 0
                          • michael.pusch
                            michael.pusch @Homoran last edited by michael.pusch

                            @homoran Screenshot 2023-01-25 211846.png

                            Screenshot 2023-01-25 212005.png

                            wendy2702 1 Reply Last reply Reply Quote 0
                            • wendy2702
                              wendy2702 @michael.pusch last edited by

                              @michael-pusch Das ist nur der Filter.

                              Debug stellt man in der Instanz ein wo jetzt Info steht.

                              michael.pusch 1 Reply Last reply Reply Quote 0
                              • michael.pusch
                                michael.pusch @wendy2702 last edited by

                                @wendy2702

                                thx... naja, bin mit dem ding a ned jeden tag auf du und du 😉
                                sekunde

                                1 Reply Last reply Reply Quote 0
                                • wendy2702
                                  wendy2702 last edited by

                                  7e6f6f66-0e45-41b8-a849-37f458f09c3a-grafik.png

                                  michael.pusch 1 Reply Last reply Reply Quote 0
                                  • michael.pusch
                                    michael.pusch @wendy2702 last edited by

                                    @wendy2702

                                    modbus.0
                                    	2023-01-25 21:24:26.494	debug	Cleaning up request fifo.
                                    modbus.0
                                    	2023-01-25 21:24:26.493	debug	Clearing timeout of the current request.
                                    modbus.0
                                    	2023-01-25 21:24:26.487	info	Disconnected from slave
                                    modbus.0
                                    	2023-01-25 21:24:26.036	warn	Poll error count: 1 code: "App Timeout"
                                    modbus.0
                                    	2023-01-25 21:24:25.484	error	Cannot write single register [38407]: {"err":"timeout","timeout":5000}
                                    modbus.0
                                    	2023-01-25 21:24:25.483	error	Request timed out.
                                    modbus.0
                                    	2023-01-25 21:24:25.482	warn	Error: undefined
                                    modbus.0
                                    	2023-01-25 21:24:20.836	debug	[DevID_10/inputRegs] Poll address 13568 - 21 registers
                                    modbus.0
                                    	2023-01-25 21:24:20.836	debug	[DevID_10] Poll start ---------------------
                                    modbus.0
                                    	2023-01-25 21:24:20.585	error	Error response: Function code received in the query is not recognized or allowed by slave
                                    modbus.0
                                    	2023-01-25 21:24:20.584	error	Error response for FCx6: Illegal Function
                                    modbus.0
                                    	2023-01-25 21:24:20.473	debug	state Changed ack=false: modbus.0.holdingRegisters.38407_PV_System_LadeStatus: {"val":1,"ack":false,"ts":1674678260467,"q":0,"from":"system.adapter.admin.0","user":"system.user.admin","lc":1674678260467}
                                    modbus.0
                                    	2023-01-25 21:24:19.783	debug	[DevID_10/holdingRegs] Poll address 38407 DONE
                                    modbus.0
                                    	2023-01-25 21:24:19.697	debug	[DevID_10/holdingRegs] Poll address 38407 - 1 registers
                                    modbus.0
                                    	2023-01-25 21:24:19.689	debug	[DevID_10/inputRegs/13697] Calculation result = 0.84, type = number
                                    modbus.0
                                    	2023-01-25 21:24:19.689	debug	[DevID_10/inputRegs/13697] Formula = x / 100
                                    modbus.0
                                    	2023-01-25 21:24:19.689	debug	[DevID_10/inputRegs/13697] Input Value = 84
                                    modbus.0
                                    	2023-01-25 21:24:19.688	debug	[DevID_10/inputRegs/13696] Calculation result = 56.87, type = number
                                    modbus.0
                                    	2023-01-25 21:24:19.688	debug	[DevID_10/inputRegs/13696] Formula = x / 100
                                    modbus.0
                                    	2023-01-25 21:24:19.688	debug	[DevID_10/inputRegs/13696] Input Value = 5687
                                    modbus.0
                                    	2023-01-25 21:24:19.687	debug	[DevID_10/inputRegs] Poll address 13696 DONE
                                    modbus.0
                                    	2023-01-25 21:24:19.599	debug	[DevID_10/inputRegs] Poll address 13696 - 7 registers
                                    modbus.0
                                    	2023-01-25 21:24:19.595	debug	[DevID_10/inputRegs/13655] Calculation result = 211.15, type = number
                                    modbus.0
                                    	2023-01-25 21:24:19.592	debug	[DevID_10/inputRegs/13655] Formula = x / 100
                                    modbus.0
                                    	2023-01-25 21:24:19.592	debug	[DevID_10/inputRegs/13655] Input Value = 21115
                                    modbus.0
                                    	2023-01-25 21:24:19.591	debug	[DevID_10/inputRegs] Poll address 13655 DONE
                                    modbus.0
                                    	2023-01-25 21:24:19.501	debug	[DevID_10/inputRegs] Poll address 13655 - 1 registers
                                    modbus.0
                                    	2023-01-25 21:24:19.499	debug	[DevID_10/inputRegs/13643] Calculation result = 0, type = number
                                    modbus.0
                                    	2023-01-25 21:24:19.498	debug	[DevID_10/inputRegs/13643] Formula = x / 100
                                    modbus.0
                                    	2023-01-25 21:24:19.498	debug	[DevID_10/inputRegs/13643] Input Value = 0
                                    modbus.0
                                    	2023-01-25 21:24:19.498	debug	[DevID_10/inputRegs/13642] Calculation result = 0, type = number
                                    modbus.0
                                    	2023-01-25 21:24:19.497	debug	[DevID_10/inputRegs/13642] Formula = x / 100
                                    
                                    wendy2702 1 Reply Last reply Reply Quote 0
                                    • michael.pusch
                                      michael.pusch @wendy2702 last edited by

                                      @wendy2702 sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                                      @michael-pusch sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                                      Function code received in the query is not recognized or allowed by slave

                                      Da steht aber das dein WR den Function Code nicht akzeptiert.

                                      Also entweder register falsch, kein Holding, oder falsche Register Parameter.

                                      Screenshot 2023-01-25 194703.png

                                      Laut Hex müsste die Adresse dann 38407 lauten...

                                      es geht um die Zeile C8

                                      Glasfaser 1 Reply Last reply Reply Quote 0
                                      • wendy2702
                                        wendy2702 @michael.pusch last edited by

                                        @wendy2702 sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                                        @michael-pusch sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                                        Function code received in the query is not recognized or allowed by slave

                                        Da steht aber das dein WR den Function Code nicht akzeptiert.

                                        Also entweder register falsch, kein Holding, oder falsche Register Parameter.

                                        Ich zitiere mich selber.

                                        1 Reply Last reply Reply Quote 0
                                        • Glasfaser
                                          Glasfaser @michael.pusch last edited by

                                          @michael-pusch

                                          Write ist Holding Register

                                          eefae957-57b1-4558-9d99-1074a0376b4e-grafik.png

                                          michael.pusch 1 Reply Last reply Reply Quote 0
                                          • michael.pusch
                                            michael.pusch @Glasfaser last edited by

                                            @glasfaser

                                            Screenshot 2023-01-25 210738.png

                                            liegt ja dort

                                            Glasfaser 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            953
                                            Online

                                            31.7k
                                            Users

                                            79.7k
                                            Topics

                                            1.3m
                                            Posts

                                            master slave modbus typ
                                            4
                                            33
                                            1366
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo