    [Gelöst] MODBUS.0 Adapter fehlt Master/Slave möglichkeit?

    This topic has been deleted. Only users with topic management privileges can see it.
    • wendy2702
      wendy2702 @michael.pusch last edited by

      @michael-pusch sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

      Function code received in the query is not recognized or allowed by slave

      Da steht aber das dein WR den Function Code nicht akzeptiert.

      Also entweder register falsch, kein Holding, oder falsche Register Parameter.

      michael.pusch 1 Reply Last reply Reply Quote 0
      • michael.pusch
        michael.pusch @Homoran last edited by michael.pusch

        @homoran Screenshot 2023-01-25 211846.png

        Screenshot 2023-01-25 212005.png

        wendy2702 1 Reply Last reply Reply Quote 0
        • wendy2702
          wendy2702 @michael.pusch last edited by

          @michael-pusch Das ist nur der Filter.

          Debug stellt man in der Instanz ein wo jetzt Info steht.

          michael.pusch 1 Reply Last reply Reply Quote 0
          • michael.pusch
            michael.pusch @wendy2702 last edited by

            @wendy2702

            thx... naja, bin mit dem ding a ned jeden tag auf du und du 😉
            sekunde

            1 Reply Last reply Reply Quote 0
            • wendy2702
              wendy2702 last edited by

              7e6f6f66-0e45-41b8-a849-37f458f09c3a-grafik.png

              michael.pusch 1 Reply Last reply Reply Quote 0
              • michael.pusch
                michael.pusch @wendy2702 last edited by

                @wendy2702

                modbus.0
                	2023-01-25 21:24:26.494	debug	Cleaning up request fifo.
                modbus.0
                	2023-01-25 21:24:26.493	debug	Clearing timeout of the current request.
                modbus.0
                	2023-01-25 21:24:26.487	info	Disconnected from slave
                modbus.0
                	2023-01-25 21:24:26.036	warn	Poll error count: 1 code: "App Timeout"
                modbus.0
                	2023-01-25 21:24:25.484	error	Cannot write single register [38407]: {"err":"timeout","timeout":5000}
                modbus.0
                	2023-01-25 21:24:25.483	error	Request timed out.
                modbus.0
                	2023-01-25 21:24:25.482	warn	Error: undefined
                modbus.0
                	2023-01-25 21:24:20.836	debug	[DevID_10/inputRegs] Poll address 13568 - 21 registers
                modbus.0
                	2023-01-25 21:24:20.836	debug	[DevID_10] Poll start ---------------------
                modbus.0
                	2023-01-25 21:24:20.585	error	Error response: Function code received in the query is not recognized or allowed by slave
                modbus.0
                	2023-01-25 21:24:20.584	error	Error response for FCx6: Illegal Function
                modbus.0
                	2023-01-25 21:24:20.473	debug	state Changed ack=false: modbus.0.holdingRegisters.38407_PV_System_LadeStatus: {"val":1,"ack":false,"ts":1674678260467,"q":0,"from":"system.adapter.admin.0","user":"system.user.admin","lc":1674678260467}
                modbus.0
                	2023-01-25 21:24:19.783	debug	[DevID_10/holdingRegs] Poll address 38407 DONE
                modbus.0
                	2023-01-25 21:24:19.697	debug	[DevID_10/holdingRegs] Poll address 38407 - 1 registers
                modbus.0
                	2023-01-25 21:24:19.689	debug	[DevID_10/inputRegs/13697] Calculation result = 0.84, type = number
                modbus.0
                	2023-01-25 21:24:19.689	debug	[DevID_10/inputRegs/13697] Formula = x / 100
                modbus.0
                	2023-01-25 21:24:19.689	debug	[DevID_10/inputRegs/13697] Input Value = 84
                modbus.0
                	2023-01-25 21:24:19.688	debug	[DevID_10/inputRegs/13696] Calculation result = 56.87, type = number
                modbus.0
                	2023-01-25 21:24:19.688	debug	[DevID_10/inputRegs/13696] Formula = x / 100
                modbus.0
                	2023-01-25 21:24:19.688	debug	[DevID_10/inputRegs/13696] Input Value = 5687
                modbus.0
                	2023-01-25 21:24:19.687	debug	[DevID_10/inputRegs] Poll address 13696 DONE
                modbus.0
                	2023-01-25 21:24:19.599	debug	[DevID_10/inputRegs] Poll address 13696 - 7 registers
                modbus.0
                	2023-01-25 21:24:19.595	debug	[DevID_10/inputRegs/13655] Calculation result = 211.15, type = number
                modbus.0
                	2023-01-25 21:24:19.592	debug	[DevID_10/inputRegs/13655] Formula = x / 100
                modbus.0
                	2023-01-25 21:24:19.592	debug	[DevID_10/inputRegs/13655] Input Value = 21115
                modbus.0
                	2023-01-25 21:24:19.591	debug	[DevID_10/inputRegs] Poll address 13655 DONE
                modbus.0
                	2023-01-25 21:24:19.501	debug	[DevID_10/inputRegs] Poll address 13655 - 1 registers
                modbus.0
                	2023-01-25 21:24:19.499	debug	[DevID_10/inputRegs/13643] Calculation result = 0, type = number
                modbus.0
                	2023-01-25 21:24:19.498	debug	[DevID_10/inputRegs/13643] Formula = x / 100
                modbus.0
                	2023-01-25 21:24:19.498	debug	[DevID_10/inputRegs/13643] Input Value = 0
                modbus.0
                	2023-01-25 21:24:19.498	debug	[DevID_10/inputRegs/13642] Calculation result = 0, type = number
                modbus.0
                	2023-01-25 21:24:19.497	debug	[DevID_10/inputRegs/13642] Formula = x / 100
                
                wendy2702 1 Reply Last reply Reply Quote 0
                • michael.pusch
                  michael.pusch @wendy2702 last edited by

                  @wendy2702 sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                  @michael-pusch sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                  Function code received in the query is not recognized or allowed by slave

                  Da steht aber das dein WR den Function Code nicht akzeptiert.

                  Also entweder register falsch, kein Holding, oder falsche Register Parameter.

                  Screenshot 2023-01-25 194703.png

                  Laut Hex müsste die Adresse dann 38407 lauten...

                  es geht um die Zeile C8

                  Glasfaser 1 Reply Last reply Reply Quote 0
                  • wendy2702
                    wendy2702 @michael.pusch last edited by

                    @wendy2702 sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                    @michael-pusch sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                    Function code received in the query is not recognized or allowed by slave

                    Da steht aber das dein WR den Function Code nicht akzeptiert.

                    Also entweder register falsch, kein Holding, oder falsche Register Parameter.

                    Ich zitiere mich selber.

                    1 Reply Last reply Reply Quote 0
                    • Glasfaser
                      Glasfaser @michael.pusch last edited by

                      @michael-pusch

                      Write ist Holding Register

                      eefae957-57b1-4558-9d99-1074a0376b4e-grafik.png

                      michael.pusch 1 Reply Last reply Reply Quote 0
                      • michael.pusch
                        michael.pusch @Glasfaser last edited by

                        @glasfaser

                        Screenshot 2023-01-25 210738.png

                        liegt ja dort

                        Glasfaser 1 Reply Last reply Reply Quote 0
                        • wendy2702
                          wendy2702 last edited by wendy2702

                          0x10 ist Function Code 16

                          [FC16](Link Adresse)

                          Setze mal den haken

                          818d93c5-9167-4c26-97e7-995e0357a512-grafik.png

                          1 Reply Last reply Reply Quote 0
                          • Glasfaser
                            Glasfaser @michael.pusch last edited by Glasfaser

                            @michael-pusch

                            dann gehe ein Register am ende +1 / oder -1

                            Was ist dann

                            38408
                            38406

                            1 Reply Last reply Reply Quote 0
                            • michael.pusch
                              michael.pusch last edited by michael.pusch

                              @wendy2702 sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                              Function Code 16

                              Setze mal den haken

                              Ich "glaube" es funktioniert jetzt... Hakerl gesetzt, obwohl ich das hakerl setzen in anderen versuchen definitiv zwar schon mal gemacht hatte, aber jetzt dürfte es funktionieren. Hat sicher auch mit der "Mehrere ID´s" problematik zu tun gehabt...

                              Wenn ich am Datenpunkt manuell nun 2 eingebe soll er PV bevorzugen, wenn das nicht reicht soll er mit EVU, also Netz nachschiessen.
                              Wenn ich das eingebe, springt der Accu auf Standby da er voll ist und der Strom aus dem EVU Netz wird verwendet.

                              Wenn ich den Datenpunkt jetzt mit 1 belege, soll er nur PV nehmen... da das jetzt in der Nacht natürlich nicht reicht, springt der Accu an und geht von Standby auf Entladend.. sprich, er spricht mir den Datenpunkt im Hybridwechselrichter anscheinend definitv an und stellt mir diesen um!

                              Ich darf nur nicht "Bestätigt" anhängen, dann kommt und passiert auch nix !

                              Leute DANKE DANKE DANKE... !!!

                              wendy2702 1 Reply Last reply Reply Quote 0
                              • wendy2702
                                wendy2702 @michael.pusch last edited by

                                @michael-pusch Was kommt denn im Debug log wenn du den Wert schreibst?

                                Und wenn es funktioniert, bitte den ersten Beitrag editieren und ein [Gelöst] vor den Titel setzen

                                michael.pusch 1 Reply Last reply Reply Quote 0
                                • michael.pusch
                                  michael.pusch @wendy2702 last edited by

                                  @wendy2702

                                  modbus.0
                                  	2023-01-25 22:05:31.032	debug	[DevID_10/holdingRegs] Poll address 38407 DONE
                                  modbus.0
                                  	2023-01-25 22:05:30.939	debug	[DevID_10/holdingRegs] Poll address 38407 - 1 registers
                                  modbus.0
                                  	2023-01-25 22:05:30.938	debug	[DevID_10/inputRegs/13697] Calculation result = 0.56, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.937	debug	[DevID_10/inputRegs/13697] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.937	debug	[DevID_10/inputRegs/13697] Input Value = 56
                                  modbus.0
                                  	2023-01-25 22:05:30.937	debug	[DevID_10/inputRegs/13696] Calculation result = 56.91, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.937	debug	[DevID_10/inputRegs/13696] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.937	debug	[DevID_10/inputRegs/13696] Input Value = 5691
                                  modbus.0
                                  	2023-01-25 22:05:30.936	debug	[DevID_10/inputRegs] Poll address 13696 DONE
                                  modbus.0
                                  	2023-01-25 22:05:30.843	debug	[DevID_10/inputRegs] Poll address 13696 - 7 registers
                                  modbus.0
                                  	2023-01-25 22:05:30.841	debug	[DevID_10/inputRegs/13655] Calculation result = 211.15, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.841	debug	[DevID_10/inputRegs/13655] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.841	debug	[DevID_10/inputRegs/13655] Input Value = 21115
                                  modbus.0
                                  	2023-01-25 22:05:30.840	debug	[DevID_10/inputRegs] Poll address 13655 DONE
                                  modbus.0
                                  	2023-01-25 22:05:30.746	debug	[DevID_10/inputRegs] Poll address 13655 - 1 registers
                                  modbus.0
                                  	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13643] Calculation result = 0, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13643] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13643] Input Value = 0
                                  modbus.0
                                  	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13642] Calculation result = 0, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13642] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13642] Input Value = 0
                                  modbus.0
                                  	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13641] Calculation result = 0, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.744	debug	[DevID_10/inputRegs/13641] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.744	debug	[DevID_10/inputRegs/13641] Input Value = 0
                                  modbus.0
                                  	2023-01-25 22:05:30.744	debug	[DevID_10/inputRegs] Poll address 13641 DONE
                                  modbus.0
                                  	2023-01-25 22:05:30.634	debug	[DevID_10/inputRegs] Poll address 13641 - 3 registers
                                  modbus.0
                                  	2023-01-25 22:05:30.633	debug	[DevID_10/inputRegs/13616] Calculation result = -302.46, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.633	debug	[DevID_10/inputRegs/13616] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.633	debug	[DevID_10/inputRegs/13616] Input Value = -30246
                                  modbus.0
                                  	2023-01-25 22:05:30.632	debug	[DevID_10/inputRegs] Poll address 13616 DONE
                                  modbus.0
                                  	2023-01-25 22:05:30.538	debug	[DevID_10/inputRegs] Poll address 13616 - 1 registers
                                  modbus.0
                                  	2023-01-25 22:05:30.537	debug	[DevID_10/inputRegs/13602] Calculation result = 0.36, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.537	debug	[DevID_10/inputRegs/13602] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.537	debug	[DevID_10/inputRegs/13602] Input Value = 36
                                  modbus.0
                                  	2023-01-25 22:05:30.537	debug	[DevID_10/inputRegs/13601] Calculation result = 232.41, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.537	debug	[DevID_10/inputRegs/13601] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.536	debug	[DevID_10/inputRegs/13601] Input Value = 23241
                                  modbus.0
                                  	2023-01-25 22:05:30.536	debug	[DevID_10/inputRegs] Poll address 13601 DONE
                                  modbus.0
                                  	2023-01-25 22:05:30.447	debug	[DevID_10/inputRegs] Poll address 13601 - 2 registers
                                  modbus.0
                                  	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13588] Calculation result = 26, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13588] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13588] Input Value = 2600
                                  modbus.0
                                  	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13587] Calculation result = 24, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13587] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13587] Input Value = 2400
                                  modbus.0
                                  	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13586] Calculation result = 12, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13586] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13586] Input Value = 1200
                                  modbus.0
                                  	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13583] Calculation result = 120.34, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13583] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13583] Input Value = 12034
                                  modbus.0
                                  	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13572] Calculation result = 50, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13572] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13572] Input Value = 5000
                                  modbus.0
                                  	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13570] Calculation result = 31.86, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13570] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13570] Input Value = 3186
                                  modbus.0
                                  	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13568] Calculation result = 232.41, type = number
                                  modbus.0
                                  	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13568] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:30.440	debug	[DevID_10/inputRegs/13568] Input Value = 23241
                                  modbus.0
                                  	2023-01-25 22:05:30.440	debug	[DevID_10/inputRegs] Poll address 13568 DONE
                                  modbus.0
                                  	2023-01-25 22:05:30.388	debug	[DevID_10/inputRegs] Poll address 13568 - 21 registers
                                  modbus.0
                                  	2023-01-25 22:05:30.388	debug	[DevID_10] Poll start ---------------------
                                  modbus.0
                                  	2023-01-25 22:05:29.337	debug	[DevID_10/holdingRegs] Poll address 38407 DONE
                                  modbus.0
                                  	2023-01-25 22:05:29.242	debug	[DevID_10/holdingRegs] Poll address 38407 - 1 registers
                                  modbus.0
                                  	2023-01-25 22:05:29.241	debug	[DevID_10/inputRegs/13697] Calculation result = 0.56, type = number
                                  modbus.0
                                  	2023-01-25 22:05:29.241	debug	[DevID_10/inputRegs/13697] Formula = x / 100
                                  modbus.0
                                  	2023-01-25 22:05:29.241	debug	[DevID_10/inputRegs/13697] Input Value = 56
                                  

                                  muss man suchen, 38407

                                  wendy2702 1 Reply Last reply Reply Quote 0
                                  • wendy2702
                                    wendy2702 @michael.pusch last edited by

                                    @michael-pusch sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                                    2023-01-25 22:05:31.032 debug [DevID_10/holdingRegs] Poll address 38407 DONE

                                    Zumindest kein Reject.

                                    Sieht also erst mal gut aus.

                                    michael.pusch 1 Reply Last reply Reply Quote 1
                                    • michael.pusch
                                      michael.pusch @wendy2702 last edited by michael.pusch

                                      @wendy2702
                                      @Glasfaser
                                      @Homoran

                                      Danke !

                                      Werd das im Auge behalten, ist aber dermassen MÄCHTIG die gesamte ioBroker umgebung und die meisten User wissen das garnicht zu schätzen was ich hier immer wieder lesen muss...!
                                      Und ihr steckt da so viel Zeit, Geld und Nerven trotzdem noch immer in das Projekt...

                                      Danke nochmals und Hut ab !!!!

                                      1 Reply Last reply Reply Quote 1
                                      • First post
                                        Last post

                                      Support us

                                      ioBroker
                                      Community Adapters
                                      Donate

                                      930
                                      Online

                                      31.7k
                                      Users

                                      79.7k
                                      Topics

                                      1.3m
                                      Posts

                                      master slave modbus typ
                                      4
                                      33
                                      1368
                                      Loading More Posts
                                      • Oldest to Newest
                                      • Newest to Oldest
                                      • Most Votes
                                      Reply
                                      • Reply as topic
                                      Log in to reply
                                      Community
                                      Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                      The ioBroker Community 2014-2023
                                      logo