    5. [Gelöst] MODBUS.0 Adapter fehlt Master/Slave möglichkeit?

    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    [Gelöst] MODBUS.0 Adapter fehlt Master/Slave möglichkeit?

    This topic has been deleted. Only users with topic management privileges can see it.
    • michael.pusch
      michael.pusch @wendy2702 last edited by

      @wendy2702

      thx... naja, bin mit dem ding a ned jeden tag auf du und du 😉
      sekunde

      1 Reply Last reply Reply Quote 0
      • wendy2702
        wendy2702 last edited by

        7e6f6f66-0e45-41b8-a849-37f458f09c3a-grafik.png

        michael.pusch 1 Reply Last reply Reply Quote 0
        • michael.pusch
          michael.pusch @wendy2702 last edited by

          @wendy2702

          modbus.0
          	2023-01-25 21:24:26.494	debug	Cleaning up request fifo.
          modbus.0
          	2023-01-25 21:24:26.493	debug	Clearing timeout of the current request.
          modbus.0
          	2023-01-25 21:24:26.487	info	Disconnected from slave
          modbus.0
          	2023-01-25 21:24:26.036	warn	Poll error count: 1 code: "App Timeout"
          modbus.0
          	2023-01-25 21:24:25.484	error	Cannot write single register [38407]: {"err":"timeout","timeout":5000}
          modbus.0
          	2023-01-25 21:24:25.483	error	Request timed out.
          modbus.0
          	2023-01-25 21:24:25.482	warn	Error: undefined
          modbus.0
          	2023-01-25 21:24:20.836	debug	[DevID_10/inputRegs] Poll address 13568 - 21 registers
          modbus.0
          	2023-01-25 21:24:20.836	debug	[DevID_10] Poll start ---------------------
          modbus.0
          	2023-01-25 21:24:20.585	error	Error response: Function code received in the query is not recognized or allowed by slave
          modbus.0
          	2023-01-25 21:24:20.584	error	Error response for FCx6: Illegal Function
          modbus.0
          	2023-01-25 21:24:20.473	debug	state Changed ack=false: modbus.0.holdingRegisters.38407_PV_System_LadeStatus: {"val":1,"ack":false,"ts":1674678260467,"q":0,"from":"system.adapter.admin.0","user":"system.user.admin","lc":1674678260467}
          modbus.0
          	2023-01-25 21:24:19.783	debug	[DevID_10/holdingRegs] Poll address 38407 DONE
          modbus.0
          	2023-01-25 21:24:19.697	debug	[DevID_10/holdingRegs] Poll address 38407 - 1 registers
          modbus.0
          	2023-01-25 21:24:19.689	debug	[DevID_10/inputRegs/13697] Calculation result = 0.84, type = number
          modbus.0
          	2023-01-25 21:24:19.689	debug	[DevID_10/inputRegs/13697] Formula = x / 100
          modbus.0
          	2023-01-25 21:24:19.689	debug	[DevID_10/inputRegs/13697] Input Value = 84
          modbus.0
          	2023-01-25 21:24:19.688	debug	[DevID_10/inputRegs/13696] Calculation result = 56.87, type = number
          modbus.0
          	2023-01-25 21:24:19.688	debug	[DevID_10/inputRegs/13696] Formula = x / 100
          modbus.0
          	2023-01-25 21:24:19.688	debug	[DevID_10/inputRegs/13696] Input Value = 5687
          modbus.0
          	2023-01-25 21:24:19.687	debug	[DevID_10/inputRegs] Poll address 13696 DONE
          modbus.0
          	2023-01-25 21:24:19.599	debug	[DevID_10/inputRegs] Poll address 13696 - 7 registers
          modbus.0
          	2023-01-25 21:24:19.595	debug	[DevID_10/inputRegs/13655] Calculation result = 211.15, type = number
          modbus.0
          	2023-01-25 21:24:19.592	debug	[DevID_10/inputRegs/13655] Formula = x / 100
          modbus.0
          	2023-01-25 21:24:19.592	debug	[DevID_10/inputRegs/13655] Input Value = 21115
          modbus.0
          	2023-01-25 21:24:19.591	debug	[DevID_10/inputRegs] Poll address 13655 DONE
          modbus.0
          	2023-01-25 21:24:19.501	debug	[DevID_10/inputRegs] Poll address 13655 - 1 registers
          modbus.0
          	2023-01-25 21:24:19.499	debug	[DevID_10/inputRegs/13643] Calculation result = 0, type = number
          modbus.0
          	2023-01-25 21:24:19.498	debug	[DevID_10/inputRegs/13643] Formula = x / 100
          modbus.0
          	2023-01-25 21:24:19.498	debug	[DevID_10/inputRegs/13643] Input Value = 0
          modbus.0
          	2023-01-25 21:24:19.498	debug	[DevID_10/inputRegs/13642] Calculation result = 0, type = number
          modbus.0
          	2023-01-25 21:24:19.497	debug	[DevID_10/inputRegs/13642] Formula = x / 100
          
          wendy2702 1 Reply Last reply Reply Quote 0
          • michael.pusch
            michael.pusch @wendy2702 last edited by

            @wendy2702 sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

            @michael-pusch sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

            Function code received in the query is not recognized or allowed by slave

            Da steht aber das dein WR den Function Code nicht akzeptiert.

            Also entweder register falsch, kein Holding, oder falsche Register Parameter.

            Screenshot 2023-01-25 194703.png

            Laut Hex müsste die Adresse dann 38407 lauten...

            es geht um die Zeile C8

            Glasfaser 1 Reply Last reply Reply Quote 0
            • wendy2702
              wendy2702 @michael.pusch last edited by

              @wendy2702 sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

              @michael-pusch sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

              Function code received in the query is not recognized or allowed by slave

              Da steht aber das dein WR den Function Code nicht akzeptiert.

              Also entweder register falsch, kein Holding, oder falsche Register Parameter.

              Ich zitiere mich selber.

              1 Reply Last reply Reply Quote 0
              • Glasfaser
                Glasfaser @michael.pusch last edited by

                @michael-pusch

                Write ist Holding Register

                eefae957-57b1-4558-9d99-1074a0376b4e-grafik.png

                michael.pusch 1 Reply Last reply Reply Quote 0
                • michael.pusch
                  michael.pusch @Glasfaser last edited by

                  @glasfaser

                  Screenshot 2023-01-25 210738.png

                  liegt ja dort

                  Glasfaser 1 Reply Last reply Reply Quote 0
                  • wendy2702
                    wendy2702 last edited by wendy2702

                    0x10 ist Function Code 16

                    [FC16](Link Adresse)

                    Setze mal den haken

                    818d93c5-9167-4c26-97e7-995e0357a512-grafik.png

                    1 Reply Last reply Reply Quote 0
                    • Glasfaser
                      Glasfaser @michael.pusch last edited by Glasfaser

                      @michael-pusch

                      dann gehe ein Register am ende +1 / oder -1

                      Was ist dann

                      38408
                      38406

                      1 Reply Last reply Reply Quote 0
                      • michael.pusch
                        michael.pusch last edited by michael.pusch

                        @wendy2702 sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                        Function Code 16

                        Setze mal den haken

                        Ich "glaube" es funktioniert jetzt... Hakerl gesetzt, obwohl ich das hakerl setzen in anderen versuchen definitiv zwar schon mal gemacht hatte, aber jetzt dürfte es funktionieren. Hat sicher auch mit der "Mehrere ID´s" problematik zu tun gehabt...

                        Wenn ich am Datenpunkt manuell nun 2 eingebe soll er PV bevorzugen, wenn das nicht reicht soll er mit EVU, also Netz nachschiessen.
                        Wenn ich das eingebe, springt der Accu auf Standby da er voll ist und der Strom aus dem EVU Netz wird verwendet.

                        Wenn ich den Datenpunkt jetzt mit 1 belege, soll er nur PV nehmen... da das jetzt in der Nacht natürlich nicht reicht, springt der Accu an und geht von Standby auf Entladend.. sprich, er spricht mir den Datenpunkt im Hybridwechselrichter anscheinend definitv an und stellt mir diesen um!

                        Ich darf nur nicht "Bestätigt" anhängen, dann kommt und passiert auch nix !

                        Leute DANKE DANKE DANKE... !!!

                        wendy2702 1 Reply Last reply Reply Quote 0
                        • wendy2702
                          wendy2702 @michael.pusch last edited by

                          @michael-pusch Was kommt denn im Debug log wenn du den Wert schreibst?

                          Und wenn es funktioniert, bitte den ersten Beitrag editieren und ein [Gelöst] vor den Titel setzen

                          michael.pusch 1 Reply Last reply Reply Quote 0
                          • michael.pusch
                            michael.pusch @wendy2702 last edited by

                            @wendy2702

                            modbus.0
                            	2023-01-25 22:05:31.032	debug	[DevID_10/holdingRegs] Poll address 38407 DONE
                            modbus.0
                            	2023-01-25 22:05:30.939	debug	[DevID_10/holdingRegs] Poll address 38407 - 1 registers
                            modbus.0
                            	2023-01-25 22:05:30.938	debug	[DevID_10/inputRegs/13697] Calculation result = 0.56, type = number
                            modbus.0
                            	2023-01-25 22:05:30.937	debug	[DevID_10/inputRegs/13697] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.937	debug	[DevID_10/inputRegs/13697] Input Value = 56
                            modbus.0
                            	2023-01-25 22:05:30.937	debug	[DevID_10/inputRegs/13696] Calculation result = 56.91, type = number
                            modbus.0
                            	2023-01-25 22:05:30.937	debug	[DevID_10/inputRegs/13696] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.937	debug	[DevID_10/inputRegs/13696] Input Value = 5691
                            modbus.0
                            	2023-01-25 22:05:30.936	debug	[DevID_10/inputRegs] Poll address 13696 DONE
                            modbus.0
                            	2023-01-25 22:05:30.843	debug	[DevID_10/inputRegs] Poll address 13696 - 7 registers
                            modbus.0
                            	2023-01-25 22:05:30.841	debug	[DevID_10/inputRegs/13655] Calculation result = 211.15, type = number
                            modbus.0
                            	2023-01-25 22:05:30.841	debug	[DevID_10/inputRegs/13655] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.841	debug	[DevID_10/inputRegs/13655] Input Value = 21115
                            modbus.0
                            	2023-01-25 22:05:30.840	debug	[DevID_10/inputRegs] Poll address 13655 DONE
                            modbus.0
                            	2023-01-25 22:05:30.746	debug	[DevID_10/inputRegs] Poll address 13655 - 1 registers
                            modbus.0
                            	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13643] Calculation result = 0, type = number
                            modbus.0
                            	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13643] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13643] Input Value = 0
                            modbus.0
                            	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13642] Calculation result = 0, type = number
                            modbus.0
                            	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13642] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13642] Input Value = 0
                            modbus.0
                            	2023-01-25 22:05:30.745	debug	[DevID_10/inputRegs/13641] Calculation result = 0, type = number
                            modbus.0
                            	2023-01-25 22:05:30.744	debug	[DevID_10/inputRegs/13641] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.744	debug	[DevID_10/inputRegs/13641] Input Value = 0
                            modbus.0
                            	2023-01-25 22:05:30.744	debug	[DevID_10/inputRegs] Poll address 13641 DONE
                            modbus.0
                            	2023-01-25 22:05:30.634	debug	[DevID_10/inputRegs] Poll address 13641 - 3 registers
                            modbus.0
                            	2023-01-25 22:05:30.633	debug	[DevID_10/inputRegs/13616] Calculation result = -302.46, type = number
                            modbus.0
                            	2023-01-25 22:05:30.633	debug	[DevID_10/inputRegs/13616] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.633	debug	[DevID_10/inputRegs/13616] Input Value = -30246
                            modbus.0
                            	2023-01-25 22:05:30.632	debug	[DevID_10/inputRegs] Poll address 13616 DONE
                            modbus.0
                            	2023-01-25 22:05:30.538	debug	[DevID_10/inputRegs] Poll address 13616 - 1 registers
                            modbus.0
                            	2023-01-25 22:05:30.537	debug	[DevID_10/inputRegs/13602] Calculation result = 0.36, type = number
                            modbus.0
                            	2023-01-25 22:05:30.537	debug	[DevID_10/inputRegs/13602] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.537	debug	[DevID_10/inputRegs/13602] Input Value = 36
                            modbus.0
                            	2023-01-25 22:05:30.537	debug	[DevID_10/inputRegs/13601] Calculation result = 232.41, type = number
                            modbus.0
                            	2023-01-25 22:05:30.537	debug	[DevID_10/inputRegs/13601] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.536	debug	[DevID_10/inputRegs/13601] Input Value = 23241
                            modbus.0
                            	2023-01-25 22:05:30.536	debug	[DevID_10/inputRegs] Poll address 13601 DONE
                            modbus.0
                            	2023-01-25 22:05:30.447	debug	[DevID_10/inputRegs] Poll address 13601 - 2 registers
                            modbus.0
                            	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13588] Calculation result = 26, type = number
                            modbus.0
                            	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13588] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13588] Input Value = 2600
                            modbus.0
                            	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13587] Calculation result = 24, type = number
                            modbus.0
                            	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13587] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13587] Input Value = 2400
                            modbus.0
                            	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13586] Calculation result = 12, type = number
                            modbus.0
                            	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13586] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13586] Input Value = 1200
                            modbus.0
                            	2023-01-25 22:05:30.442	debug	[DevID_10/inputRegs/13583] Calculation result = 120.34, type = number
                            modbus.0
                            	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13583] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13583] Input Value = 12034
                            modbus.0
                            	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13572] Calculation result = 50, type = number
                            modbus.0
                            	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13572] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13572] Input Value = 5000
                            modbus.0
                            	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13570] Calculation result = 31.86, type = number
                            modbus.0
                            	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13570] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13570] Input Value = 3186
                            modbus.0
                            	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13568] Calculation result = 232.41, type = number
                            modbus.0
                            	2023-01-25 22:05:30.441	debug	[DevID_10/inputRegs/13568] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:30.440	debug	[DevID_10/inputRegs/13568] Input Value = 23241
                            modbus.0
                            	2023-01-25 22:05:30.440	debug	[DevID_10/inputRegs] Poll address 13568 DONE
                            modbus.0
                            	2023-01-25 22:05:30.388	debug	[DevID_10/inputRegs] Poll address 13568 - 21 registers
                            modbus.0
                            	2023-01-25 22:05:30.388	debug	[DevID_10] Poll start ---------------------
                            modbus.0
                            	2023-01-25 22:05:29.337	debug	[DevID_10/holdingRegs] Poll address 38407 DONE
                            modbus.0
                            	2023-01-25 22:05:29.242	debug	[DevID_10/holdingRegs] Poll address 38407 - 1 registers
                            modbus.0
                            	2023-01-25 22:05:29.241	debug	[DevID_10/inputRegs/13697] Calculation result = 0.56, type = number
                            modbus.0
                            	2023-01-25 22:05:29.241	debug	[DevID_10/inputRegs/13697] Formula = x / 100
                            modbus.0
                            	2023-01-25 22:05:29.241	debug	[DevID_10/inputRegs/13697] Input Value = 56
                            

                            muss man suchen, 38407

                            wendy2702 1 Reply Last reply Reply Quote 0
                            • wendy2702
                              wendy2702 @michael.pusch last edited by

                              @michael-pusch sagte in MODBUS.0 Adapter fehlt Master/Slave möglichkeit?:

                              2023-01-25 22:05:31.032 debug [DevID_10/holdingRegs] Poll address 38407 DONE

                              Zumindest kein Reject.

                              Sieht also erst mal gut aus.

                              michael.pusch 1 Reply Last reply Reply Quote 1
                              • michael.pusch
                                michael.pusch @wendy2702 last edited by michael.pusch

                                @wendy2702
                                @Glasfaser
                                @Homoran

                                Danke !

                                Werd das im Auge behalten, ist aber dermassen MÄCHTIG die gesamte ioBroker umgebung und die meisten User wissen das garnicht zu schätzen was ich hier immer wieder lesen muss...!
                                Und ihr steckt da so viel Zeit, Geld und Nerven trotzdem noch immer in das Projekt...

                                Danke nochmals und Hut ab !!!!

                                1 Reply Last reply Reply Quote 1
                                • First post
                                  Last post

                                Support us

                                ioBroker
                                Community Adapters
                                Donate

                                982
                                Online

                                31.7k
                                Users

                                79.7k
                                Topics

                                1.3m
                                Posts

                                master slave modbus typ
                                4
                                33
                                1366
                                Loading More Posts
                                • Oldest to Newest
                                • Newest to Oldest
                                • Most Votes
                                Reply
                                • Reply as topic
                                Log in to reply
                                Community
                                Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                The ioBroker Community 2014-2023
                                logo