Navigation

    Logo
    • Register
    • Login
    • Search
    • Recent
    • Tags
    • Unread
    • Categories
    • Unreplied
    • Popular
    • GitHub
    • Docu
    • Hilfe
    1. Home
    2. Deutsch
    3. Tester
    4. Alpha Testing: OCPP Wallbox Adapter

    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    Alpha Testing: OCPP Wallbox Adapter

    This topic has been deleted. Only users with topic management privileges can see it.
    • foxriver76
      foxriver76 Developer last edited by foxriver76

      @jrlohni sagte in Alpha Testing: OCPP Wallbox Adapter:

      Mein Protokoll sagt zur Phasenumschaltung nur:
      Cannot execute command "numberPhrases" for "/.1": No chargeLimit set.

      Ist das kopiert? Weil da ein Typo drin ist, der codetechnisch nicht existieren sollte. "numberPhrases"

      Ja, man kann die Anzahl der Phasen nur mitgeben, wenn man auch ein chargeLimit setzt.

      Das chargeLimit kann ich aber auch nicht setzen.

      Wieso?

      Zu "authList" sagt er mir:
      Removing LocalAuthListManagement functionality as unsupported

      Dann wird es laut Config nicht supported, solltest du bei den supported Profiles sehen können.

      Leider bekomme ich keine Config von der Station... Oder wo wäre die abgelegt? Ist doch richtig das du die mit runterlädst beim verbinden, oder?

      Es sollte einen channel geben ocpp.0.<wb-name>.configuration ansonsten sollte es eine Fehlermeldung geben.

      1 Reply Last reply Reply Quote 0
      • F
        frank11 last edited by frank11

        Seit gestern Abend ist mein Auto im Schnarchlademodus mit 4,1kW.

        Wenn ich versuche, das chargeLimit auf 16A zu setzen, erscheint dieser Fehler:

        Cannot execute command "chargeLimit" for "/21178121966125.1": Timeout for message 565b916f-e60f-4559-83e9-2dc74145d1ce

        foxriver76 1 Reply Last reply Reply Quote 0
        • foxriver76
          foxriver76 Developer @frank11 last edited by

          @frank11 vermutlich nicht nur beim senden des charge limits? Oder gehen andere Befehle noch?

          F 1 Reply Last reply Reply Quote 0
          • F
            frank11 @foxriver76 last edited by

            @foxriver76 Na geil, mal wieder ganz unbewusst auf Englisch geswitcht. 🙂

            Ja genau. ich habe ioBroker mal neu gestartet, dann ging es wieder.

            Die ersten Fehler kamen eine Stunde bevor ich überhaupt zu Hause war:

            2023-01-26 14:05:40.911 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 14:10:40.927 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 14:15:40.921 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 14:20:40.931 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 14:23:10.889 - warn: ocpp.0 (1106987) Client "/21178121966125" timed out
            2023-01-26 14:25:46.987 - info: ocpp.0 (1106987) New device connected: "/21178121966125"
            2023-01-26 14:25:48.059 - info: ocpp.0 (1106987) Requesting BootNotification from "/21178121966125"
            2023-01-26 14:26:18.068 - warn: ocpp.0 (1106987) Could not request states of "/21178121966125": Timeout for message ffa77cb5-08a9-481f-b88a-6b8c82a3f5bd
            2023-01-26 14:26:18.069 - info: ocpp.0 (1106987) Sending GetConfiguration to "/21178121966125"
            2023-01-26 14:26:48.076 - error: ocpp.0 (1106987) Could not request configuration of /21178121966125: Timeout for message aedefd37-2d5a-49d4-9a40-6589e8682af8
            2023-01-26 14:27:17.058 - warn: ocpp.0 (1106987) Client "/21178121966125" timed out
            2023-01-26 14:38:21.150 - info: ocpp.0 (1106987) New valid connection from "/21178121966125" (http/ocpp1.6)
            2023-01-26 14:38:21.970 - info: ocpp.0 (1106987) New device connected: "/21178121966125"
            2023-01-26 14:38:22.052 - info: ocpp.0 (1106987) Received boot notification from "/21178121966125"
            2023-01-26 14:38:22.397 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 14:38:23.053 - info: ocpp.0 (1106987) Requesting StatusNotification from "/21178121966125"
            2023-01-26 14:38:23.360 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 14:38:24.309 - info: ocpp.0 (1106987) Requesting MeterValues from "/21178121966125"
            2023-01-26 14:38:24.720 - info: ocpp.0 (1106987) Received MeterValues from "/21178121966125.1"
            2023-01-26 14:38:25.446 - info: ocpp.0 (1106987) Sending GetConfiguration to "/21178121966125"
            2023-01-26 14:38:26.054 - info: ocpp.0 (1106987) Supported profiles by client "/21178121966125" are "Core,Local Auth List Management,Reservation,Smart Charging,Remote Trigger"
            2023-01-26 14:43:22.999 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 14:48:22.986 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 14:53:22.927 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 14:58:32.017 - warn: ocpp.0 (1106987) Client "/21178121966125" timed out
            2023-01-26 15:00:35.149 - info: ocpp.0 (1106987) New device connected: "/21178121966125"
            2023-01-26 15:00:35.198 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 15:00:36.209 - info: ocpp.0 (1106987) Requesting BootNotification from "/21178121966125"
            2023-01-26 15:01:06.213 - warn: ocpp.0 (1106987) Could not request states of "/21178121966125": Timeout for message a11d3196-971d-4471-bb7f-b607c9524555
            2023-01-26 15:01:06.214 - info: ocpp.0 (1106987) Sending GetConfiguration to "/21178121966125"
            2023-01-26 15:01:36.218 - error: ocpp.0 (1106987) Could not request configuration of /21178121966125: Timeout for message 88424f98-55f7-4532-9114-0b3a5c2838d9
            2023-01-26 15:02:05.209 - warn: ocpp.0 (1106987) Client "/21178121966125" timed out
            2023-01-26 16:10:20.931 - info: ocpp.0 (1106987) New valid connection from "/21178121966125" (http/ocpp1.6)
            2023-01-26 16:10:21.605 - info: ocpp.0 (1106987) New device connected: "/21178121966125"
            2023-01-26 16:10:21.689 - info: ocpp.0 (1106987) Received boot notification from "/21178121966125"
            2023-01-26 16:10:22.030 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 16:10:22.689 - info: ocpp.0 (1106987) Requesting StatusNotification from "/21178121966125"
            2023-01-26 16:10:22.852 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 16:10:23.797 - info: ocpp.0 (1106987) Requesting MeterValues from "/21178121966125"
            2023-01-26 16:10:24.176 - info: ocpp.0 (1106987) Received MeterValues from "/21178121966125.1"
            2023-01-26 16:10:24.906 - info: ocpp.0 (1106987) Sending GetConfiguration to "/21178121966125"
            2023-01-26 16:10:25.461 - info: ocpp.0 (1106987) Supported profiles by client "/21178121966125" are "Core,Local Auth List Management,Reservation,Smart Charging,Remote Trigger"
            2023-01-26 16:15:22.641 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 16:20:22.651 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 16:25:22.661 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 16:30:22.613 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 16:35:22.667 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 16:40:22.681 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 16:45:22.618 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 16:50:22.629 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 16:55:22.670 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 17:00:22.654 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 17:05:22.658 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 17:10:22.667 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 17:15:22.636 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Available
            2023-01-26 17:17:20.261 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Preparing
            2023-01-26 17:17:26.298 - info: ocpp.0 (1106987) Received Authorization Request from "/21178121966125" with idTag "*****"
            2023-01-26 17:17:26.432 - info: ocpp.0 (1106987) Received Start transaction from "/21178121966125.1"
            2023-01-26 17:17:28.548 - info: ocpp.0 (1106987) Received Status Notification from "/21178121966125.1": Charging
            2023-01-26 17:17:33.056 - info: ocpp.0 (1106987) Received MeterValues from "/21178121966125.1"
            2023-01-26 17:17:37.971 - info: ocpp.0 (1106987) Received MeterValues from "/21178121966125.1"
            2023-01-26 17:17:42.910 - info: ocpp.0 (1106987) Received MeterValues from "/21178121966125.1"
            2023-01-26 17:17:47.865 - info: ocpp.0 (1106987) Received MeterValues from "/21178121966125.1"
            2023-01-26 17:17:52.882 - info: ocpp.0 (1106987) Received MeterValues from "/21178121966125.1"
            2023-01-26 17:17:57.903 - info: ocpp.0 (1106987) Received MeterValues from "/21178121966125.1"

            foxriver76 1 Reply Last reply Reply Quote 0
            • foxriver76
              foxriver76 Developer @frank11 last edited by foxriver76

              @frank11 Daten empfangen hat er bis zum Neustart? Ind auch nachdem du nicht mehr steuern konntest? Also MeterValues zb

              F 1 Reply Last reply Reply Quote 0
              • F
                frank11 @foxriver76 last edited by frank11

                @foxriver76 Doch, es kamen die ganze Zeit Daten. Das ist ja das merkwürdige.
                Sonst hätte ich das ja gar nicht gesehen.

                Ich dachte erst, mein Auto würde nicht mehr Power annehmen, weil ich den zum Test mal auf 4km Reichweite runtergefahren habe.

                Da ich heute HomeOffice mache, wollte ich erst warten.

                (Das Gute: genau das hatte der am Anfang der 50km Heimfahrt angezeigt.)

                foxriver76 1 Reply Last reply Reply Quote 0
                • foxriver76
                  foxriver76 Developer @frank11 last edited by

                  @frank11 Hm.. das Verhalten hatte ich auch schon öfter beobachtet, hatte insgeheim gehofft, dass es nach den größeren Überarbeitungen nicht mehr auftritt. Äußerst komisch, dass er Daten empfängt über die Verbindung und das hinschicken ins leere läuft.

                  Ich beobachte mal ob es bei mir auch wieder auftritt nach gewisser Zeit. Notfalls werde ich einen Workaround einbauen, villt. finde ich auch das Problem irgendwo tief ind er genutzten Library, hatte da allerdings schon mal erfolglos geschaut.

                  F 1 Reply Last reply Reply Quote 1
                  • F
                    frank11 @foxriver76 last edited by

                    @foxriver76 Mein Workaround ist erstmal, direkt aufs Handy zu schauen. Der BMW zeigt an, wann der fertig sein will. Wenn das24 Stunden dauert, starte ich den Adapter einfach durch.

                    1 Reply Last reply Reply Quote 0
                    • J
                      Jrlohni last edited by

                      @foxriver76, ne war wohl abgetippt.. Habe noch mal kontrolliert. Das "r" ist dort nicht vorhanden.

                      Bei "chargeLimit" sagt er mir immer:
                      "Charge point responded with "Rejected" on changing charge limit"
                      in einer früheren Version ging es mal.

                      Ja den Channel gibt es mit diversen States:
                      2f4b25f9-49f1-4c33-8cf1-f28b4e1184ea-image.png

                      Für supportetFeatureProfiles steht dort: Core,FirmwareManagement,SmartCharging,RemoteTrigger

                      Also wohl kein LocalAuthListManagement 🙂

                      Grüße und vielen Dank!

                      foxriver76 F 2 Replies Last reply Reply Quote 0
                      • foxriver76
                        foxriver76 Developer @Jrlohni last edited by

                        @jrlohni Hast du den richtigen chargeLimitType eingestellt? Lt. config bei dir nur Current erlaubt, also regeln in Ampere. Ansonsten gerne mal debug Log zeigen, evtl. sehen wir dann was da falsch läuft. Bzw. von welchem Hersteller ist die Box? Bei mir Pulsar Plus gibts aktuell auch Probleme, habe denen geschrieben, allerdings noch keine sinnvolle Antwort erhalten was sie oder ich falsch machen.

                        J F 2 Replies Last reply Reply Quote 0
                        • J
                          Jrlohni @foxriver76 last edited by

                          @foxriver76 Anbei meine Einstellungen, ja habe "A" gewählt:
                          e0e4f329-afbf-483e-8739-6da3424658c8-image.png

                          Es handelt sich bei mir um einen go-e Charger in der Gemini flex Version.

                          Log:

                          ocpp.0
                          2023-02-06 15:17:13.083	info	Received MeterValues from "/.1"
                          ocpp.0
                          2023-02-06 14:57:57.923	error	Cannot execute command "availability" for "/.1":
                          ocpp.0
                          2023-02-06 14:57:49.924	warn	Charge point responded with "Rejected" on changing charge limit
                          ocpp.0
                          2023-02-06 14:57:42.673	error	Cannot execute command "numberPhases" for "/.1": No chargeLimit set
                          ocpp.0
                          2023-02-06 14:57:15.924	info	Removing LocalAuthListManagement functionality as unsupported
                          ocpp.0
                          2023-02-06 14:57:15.837	info	Supported profiles by client "/" are "Core,FirmwareManagement,SmartCharging,RemoteTrigger"
                          ocpp.0
                          2023-02-06 14:57:15.595	info	Sending GetConfiguration to "/"
                          ocpp.0
                          2023-02-06 14:57:14.440	info	Requesting MeterValues from "/"
                          ocpp.0
                          2023-02-06 14:57:13.429	info	Received Status Notification from "/.1": Finishing
                          ocpp.0
                          2023-02-06 14:57:13.301	info	Requesting StatusNotification from "/"
                          ocpp.0
                          2023-02-06 14:57:12.704	info	Received MeterValues from "/.1"
                          ocpp.0
                          2023-02-06 14:57:12.574	info	Received Status Notification from "/.1": Finishing
                          ocpp.0
                          2023-02-06 14:57:12.479	info	Received Status Notification from "/.0": Available
                          ocpp.0
                          2023-02-06 14:57:12.301	info	Received boot notification from "/"
                          ocpp.0
                          2023-02-06 14:57:12.184	info	New device connected: "/"
                          ocpp.0
                          2023-02-06 14:57:12.044	info	New valid connection from "/" (http/ocpp1.6)
                          ocpp.0
                          2023-02-06 14:57:02.062	info	Server listening on port 9220
                          ocpp.0
                          2023-02-06 14:57:02.006	info	Starting OCPP Server
                          ocpp.0
                          2023-02-06 14:57:01.955	info	starting. Version 0.12.2 in /opt/iobroker/node_modules/iobroker.ocpp, node: v14.21.2, js-controller: 4.0.23
                          host.raspberrypi
                          2023-02-06 14:57:00.095	info	instance system.adapter.ocpp.0 started with pid 5222
                          host.raspberrypi
                          2023-02-06 14:56:57.585	info	instance system.adapter.ocpp.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
                          host.raspberrypi
                          2023-02-06 14:56:57.024	info	stopInstance system.adapter.ocpp.0 send kill signal
                          ocpp.0
                          2023-02-06 14:56:57.005	info	Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                          ocpp.0
                          2023-02-06 14:56:57.003	info	terminating
                          ocpp.0
                          2023-02-06 14:56:56.982	info	Got terminate signal TERMINATE_YOURSELF
                          host.raspberrypi
                          2023-02-06 14:56:56.976	info	stopInstance system.adapter.ocpp.0 (force=false, process=true)
                          ocpp.0
                          2023-02-06 14:56:55.925	info	Removing LocalAuthListManagement functionality as unsupported
                          ocpp.0
                          2023-02-06 14:56:55.838	info	Supported profiles by client "/" are "Core,FirmwareManagement,SmartCharging,RemoteTrigger"
                          ocpp.0
                          2023-02-06 14:56:55.622	info	Sending GetConfiguration to "/"
                          ocpp.0
                          2023-02-06 14:56:54.471	info	Requesting MeterValues from "/"
                          ocpp.0
                          2023-02-06 14:56:53.460	info	Received Status Notification from "/.1": Finishing
                          ocpp.0
                          2023-02-06 14:56:53.363	info	Requesting StatusNotification from "/"
                          ocpp.0
                          2023-02-06 14:56:52.876	info	Received MeterValues from "/.1"
                          ocpp.0
                          2023-02-06 14:56:52.615	info	Received Status Notification from "/.1": Finishing
                          ocpp.0
                          2023-02-06 14:56:52.518	info	Received Status Notification from "/.0": Available
                          ocpp.0
                          2023-02-06 14:56:52.363	info	Received boot notification from "/"
                          ocpp.0
                          2023-02-06 14:56:52.223	info	New device connected: "/"
                          ocpp.0
                          2023-02-06 14:56:52.084	info	New valid connection from "/" (http/ocpp1.6)
                          ocpp.0
                          2023-02-06 14:56:22.111	info	Server listening on port 9220
                          ocpp.0
                          2023-02-06 14:56:22.056	info	Starting OCPP Server
                          ocpp.0
                          2023-02-06 14:56:22.018	info	starting. Version 0.12.2 in /opt/iobroker/node_modules/iobroker.ocpp, node: v14.21.2, js-controller: 4.0.23
                          

                          Habe den Adapter noch einmal neu gestartet zwischendurch 🙂

                          Grüße

                          foxriver76 1 Reply Last reply Reply Quote 0
                          • foxriver76
                            foxriver76 Developer @Jrlohni last edited by

                            @jrlohni Geht es evtl. mit numberPhases 3?

                            J 1 Reply Last reply Reply Quote 0
                            • J
                              Jrlohni @foxriver76 last edited by Jrlohni

                              @foxriver76 ging leider auch nicht. Die numberPhases nimmt er nicht an und das chargeLimit wird immer noch "Rejected". Auch mit einer Änderung von diversen Möglichkeiten von "True" und "False" ändert sich nichts.

                              f9a9d242-6091-4e3b-98a3-0869bab46c62-image.png

                              9386bd77-ecfe-4b21-bcac-e8fe630ab758-image.png

                              foxriver76 2 Replies Last reply Reply Quote 0
                              • foxriver76
                                foxriver76 Developer @Jrlohni last edited by

                                @jrlohni dann benötigt es wohl eine Änderung im Adapter, so dass man numberCharges deaktiviert indem man es auf null setzt. Ich denke dann sollte es gehen.

                                1 Reply Last reply Reply Quote 0
                                • foxriver76
                                  foxriver76 Developer @Jrlohni last edited by

                                  @jrlohni Probier bitte v0.12.3, sollte gleich auf npm sein.

                                  1 Reply Last reply Reply Quote 0
                                  • J
                                    Jrlohni last edited by

                                    @foxriver76 Leider hat die Version auch keine Besserung gebracht...
                                    b513ea97-8e51-4a2b-8ce7-74a0710c82e0-image.png

                                    Hab wirklich jede Möglichkeit durchgespielt. Habe numberPhases auf 1, 3, null, (null), NULL und 0 gesetzt...
                                    Wenn numberPhrases nicht vom Wert "number" war, gab es natürlich eine Fehlermeldung.

                                    Wie man auf den Screenshot sieht schickt der Adapter für go-e ohne Probleme Daten welche auch vom Charger angenommen werden. Ich würde aber gerne über OCPP gehen, damit ich auch mit weiteren Ladestationen, welche bald kommen, über ein System kommunizieren kann.

                                    Was mir auffällt: In der Fehlermeldung wegen der falschen Datentypen in "numberPhases" ist "startPeriod" immer 0, könnte es was damit zu tun haben?
                                    733c253f-77a8-406c-9a2f-f14a6cbbbe3b-image.png

                                    Grüße

                                    foxriver76 1 Reply Last reply Reply Quote 0
                                    • foxriver76
                                      foxriver76 Developer @Jrlohni last edited by

                                      @jrlohni ich mache mal noch eine 0.12.4 nur um sicher zu gehen, wenn du einen string null setzt, ist klar, dass dann ist mir klar, dass nix geht. Wobei Admin aus dem String null meines Wissens nach wirklich null macht.

                                      J 1 Reply Last reply Reply Quote 0
                                      • J
                                        Jrlohni @foxriver76 last edited by

                                        @foxriver76 Auch da hat sich nichts geändert, außer das nun die Fehlermeldung bei nem String nicht mehr kommt...

                                        Vielen Dank!

                                        1 Reply Last reply Reply Quote 0
                                        • F
                                          fL4sH 0 @Jrlohni last edited by fL4sH 0

                                          @jrlohni said in Alpha Testing: OCPP Wallbox Adapter:

                                          @foxriver76, ne war wohl abgetippt.. Habe noch mal kontrolliert. Das "r" ist dort nicht vorhanden.

                                          Bei "chargeLimit" sagt er mir immer:
                                          "Charge point responded with "Rejected" on changing charge limit"
                                          in einer früheren Version ging es mal.

                                          Ja den Channel gibt es mit diversen States:
                                          2f4b25f9-49f1-4c33-8cf1-f28b4e1184ea-image.png

                                          Für supportetFeatureProfiles steht dort: Core,FirmwareManagement,SmartCharging,RemoteTrigger

                                          Also wohl kein LocalAuthListManagement 🙂

                                          Grüße und vielen Dank!

                                          Versuch mal die Transaktion mit Chargelimit 0 (A oder W) zu starten, so funktioniert das aktuell bei mir. Anschließend kann das Chargelimit während die Transaktion läuft geändert werden. Wenn das Chargelimit vor dem Start gesetzt wurde kommt bei mir auch die Fehlermeldeung:

                                          ocpp.0 2023-02-08 11:55:00.033	warn	Starting transaction has been rejected by charge point
                                          
                                          1 Reply Last reply Reply Quote 0
                                          • F
                                            fL4sH 0 @foxriver76 last edited by fL4sH 0

                                            @foxriver76 said in Alpha Testing: OCPP Wallbox Adapter:

                                            @jrlohni Hast du den richtigen chargeLimitType eingestellt? Lt. config bei dir nur Current erlaubt, also regeln in Ampere. Ansonsten gerne mal debug Log zeigen, evtl. sehen wir dann was da falsch läuft. Bzw. von welchem Hersteller ist die Box? Bei mir Pulsar Plus gibts aktuell auch Probleme, habe denen geschrieben, allerdings noch keine sinnvolle Antwort erhalten was sie oder ich falsch machen.

                                            Es scheint wohl mit der aktuellen Version 0.12.4 ein Problem mit dem State numberPhases zu geben.
                                            Wenn sich das Chargelimit ändert muss man aktuell den Wert von numberPhases=2 manuell pushen damit sich die Werte in der Wallbox ändern. Wenn nur das Chargelimit geändert wird ändern sich die Daten in der Wallbox nicht.

                                            Kann es sein das in dem Befehl Sending SetChargingProfile der Value numberPhases fehlt ?

                                            Ich habe mal versucht das im Code zu beschreiben.

                                            ocpp.0 2023-02-08 12:04:28.408	info	Received Status Notification from "/TACW1142021G1020.1": Charging
                                            ocpp.0 2023-02-08 12:04:28.408	debug	{"connectorId":1,"errorCode":"NoError","info":"null","status":"Charging","vendorErrorCode":"0x0000","commandOcpp":"StatusNotification"}
                                            ocpp.0 2023-02-08 12:04:27.908	info	Received Status Notification from "/TACW1142021G1020.1": SuspendedEV
                                            ocpp.0 2023-02-08 12:04:27.908	debug {"connectorId":1,"errorCode":"NoError","info":"null","status":"SuspendedEV","vendorErrorCode":"0x0000","commandOcpp":"StatusNotification"}
                                            
                                            numberPhases wurde gesetzt      ocpp.0 2023-02-08 12:04:27.404	debug	Sending SetChargingProfile for /TACW1142021G1020.1
                                            
                                            ocpp.0 2023-02-08 12:04:15.387	info	Received MeterValues from "/TACW1142021G1020.1"
                                            ocpp.0 2023-02-08 12:04:15.387	debug	{"connectorId":1,"transactionId":1,"meterValue":[{"timestamp":"2023-02-08T11:04:15.000Z","sampledValue":[{"value":"235.30","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L1-N","unit":"V"},{"value":"0.0","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L1","unit":"A"},{"value":"0","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L1","unit":"W"},{"value":"234.30","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L2-N","unit":"V"},{"value":"0.0","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L2","unit":"A"},{"value":"0","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L2","unit":"W"},{"value":"234.20","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L3-N","unit":"V"},{"value":"0.0","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L3","unit":"A"},{"value":"0","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L3","unit":"W"},{"value":"13","context":"Sample.Periodic","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh"},{"value":"0","context":"Sample.Periodic","format":"Raw","measurand":"Current.Offered","unit":"A"},{"value":"0.0","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","unit":"A"},{"value":"0","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","unit":"W"}]}],"commandOcpp":"MeterValues"}
                                            ocpp.0 2023-02-08 12:04:00.582	info	Received Status Notification from "/TACW1142021G1020.1": SuspendedEVSE
                                            ocpp.0 2023-02-08 12:04:00.581	debug	{"connectorId":1,"errorCode":"NoError","info":"null","status":"SuspendedEVSE","vendorErrorCode":"0x0000","commandOcpp":"StatusNotification"}
                                            
                                            Chargelimit wurde gesetzt        ocpp.0 2023-02-08 12:04:00.035	debug	Sending SetChargingProfile for /TACW1142021G1020.1
                                            
                                            foxriver76 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            631
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            adapter ocpp wallbox
                                            48
                                            440
                                            78015
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo