      Wildfire0815 @Rene_HM last edited by Wildfire0815

      @rene_hm Leider nicht.
      03bcc78f-0b53-477f-82d0-e0b235804a59-grafik.png

      Wo würde ich denn den Hinweis finden, wenn die Nummer des Gerätes schon vergeben wäre? Kann es daran liegen?

      Ich bin etwas ratlos.

      Rene_HM 1 Reply Last reply Reply Quote 0
      • Rene_HM
        Rene_HM Developer @Wildfire0815 last edited by

        @wildfire0815 ändere doch einfach die Nummer nach dem "F-".

        Außerdem könntest du noch das log vom SHM selbst anschauen.

        • Kopieren des "SMA Connection Assist" von https://github.com/rg-engineering/ioBroker.semp/tree/master/docu/SMA/connection-assist.jar auf den Windows-PC und irgendwohin speichern

        connection_assist_1.PNG

        • dann eine Eingabe -Aufforderung öffnen, in das Verzeichnis wechseln, wo die jar-Datei gespeichert wurde und
        connection-assist.jar -discoverHoman
        

        aufrufen.

        • das öffnet ein Browser-Fenster
        • die SMA Geräte werden gesucht
          connection_assist_2.PNG
        • den SHM auswählen und verbinden
        • als Passwort den RID eingeben (SHM2)
        • Systemstatus speichern
          connection_assist_4.PNG

        connection_assist_4_1.PNG

        • als smasl Datei speichern und nach zip umbenenennen (Achtung! Pfad merken, wohin gespeichert wurde)

        connection_assist_5.PNG

        • in der zip ist dann ein SEMPLog.tgz
        • das SEMPLog.tgz entpacken
        • dort sind dann 5 logs der letzten 5 Stunden

        Vielleicht finden wir ja da einen Hinweis.

        W 1 Reply Last reply Reply Quote 0
        • W
          Wildfire0815 @Rene_HM last edited by

          @rene_hm said in Adapter: SMA SEMP:

          connection-assist.jar -discoverHoman

          Das hat geholfen. Danke für Deine Mühe.
          Der vorgeschlagene Wert für die Basis ID hatte bei mir nur 7 Zeichen. Das hatte ich nicht übrüft.
          In dem LOG kam dann die Meldung "Invalid ID".

          Rene_HM 1 Reply Last reply Reply Quote 0
          • Rene_HM
            Rene_HM Developer @Wildfire0815 last edited by

            @wildfire0815 sagte in Adapter: SMA SEMP:

            Basis ID hatte bei mir nur 7 Zeichen

            das habe ich auch übersehen, sorry.

            W 1 Reply Last reply Reply Quote 0
            • W
              Webwanze @Rene_HM last edited by

              Hallo,

              ich habe die aktuelle Version des Adapters auf meinem iobroker. V 0.3.1

              Nach der Erstellung der Instanz läuft diese wie gewünscht. Grün.

              Nachdem ich auch nur ein Device erstellt habe, ist das leider nicht mehr der Fall. Folgende Meldung im Log:
              unnamed.jpg

              Habe den Adapter auch schon deinstalliert/installiert, löst das Problem aber nicht.

              Grüße,

              Thomas

              C Rene_HM 2 Replies Last reply Reply Quote 0
              • C
                cb187 @Webwanze last edited by

                @webwanze

                Würde mal behaupten das es an deinem erstellen device liegt er kann den datenpunkt nicht lesen.so verstehe ich das.

                1 Reply Last reply Reply Quote 0
                • Rene_HM
                  Rene_HM Developer @Webwanze last edited by

                  @webwanze Die Fehlermeldung sagt, dass auf einen Datenpunkt, den der Adapter eigentlich anlegt, nicht zugegriffen werden kann...

                  Zeige mal den Datenbaum für dein neues Device. Der sollte irgendwie so aussehen:

                  bild.PNG

                  Bei dir fehlt wohl der State...
                  Wie heisst dein device? sind da evtl. Leerzeichen drin?

                  W 1 Reply Last reply Reply Quote 0
                  • W
                    Webwanze @Rene_HM last edited by Webwanze

                    @rene_hm
                    Datenpunkt passt. Mit State usw.
                    Leerzeichen gibt es auch nicht.
                    Auch wenn ich auf 'Schätzung' stelle, kommt der Fehler. Also ohne jeglichen Datenpunkte.

                    Nochmal zum Reproduzieren:
                    Ausgangssituation:

                    • Adapter installiert und Basiseinstellungen (IP, Port, ...) OK.
                    • Kein Device konfiguriert
                      -> Läuft!

                    Hinzufügen eines Devices:

                    • '+' klicken
                    • ID: F-00...-00...1-00 lassen
                    • Name: newDevice0 lassen
                    • Speichern
                      -> Läuft nicht mehr.

                    Zurück zur Konfiguration des Devices:

                    • Hersteller=ACME/Seriennummer=1234/Gerätetyp=Heizung/Mindestleistung=0;max. Leistung 1000; Unterbrechung erlaubt=Nein
                    • Zähler=Schätzung
                    • Schalter=Immer an; Gerät kann ein/ausgeschaltet werden=Nein
                    • Energieanforderungen aktiv = Nein
                      -> Läuft nicht

                    Habe auch versucht, alle möglichen Datenpunkte im Device zu setzen, falls der Adapter dort Daten holen will, auch wenn die Funktionalität eigentlich deaktiviert ist. Egal was ich einstelle, es funktioniert nicht. Sobald ich das gesamte Device deaktiviere (Checkbox) läuft der Adapter wieder.

                    Nachtrag:
                    In den Objekten werden wie bei deinem Screenshot alle Datenpunkte angezeigt:
                    Changed = null
                    Energy = 0 Wh
                    RecommendedState = null
                    State = null

                    Rene_HM 1 Reply Last reply Reply Quote 0
                    • Rene_HM
                      Rene_HM Developer @Webwanze last edited by

                      @webwanze sagte in Adapter: SMA SEMP:

                      State = null

                      und da sehen wir das Problem. Der Adapter versucht "waiting" dorthin zu schreiben, null sollte da nicht stehen...

                      Kopiere mal den kompletten Namen dieses Datenpunktes und poste ihn hier oder mache einen screen shot wie ich ihn gezeigt habe.

                      W 1 Reply Last reply Reply Quote 0
                      • W
                        Webwanze @Rene_HM last edited by Webwanze

                        @rene_hm
                        44432258-3b18-42db-a953-b56f84e2f52b-grafik.png

                        Muss bei mir da auch 'waiting' stehen?
                        Ich will ja nicht über semp steuern lassen. Also wartet bei mir auch nix - zumindest nicht auf den HM2.

                        Rene_HM 1 Reply Last reply Reply Quote 0
                        • Rene_HM
                          Rene_HM Developer @Webwanze last edited by

                          @webwanze ja, da wird auch "waiting" stehen, weil das der Standard-Zustand ist.

                          Ich sehe den Absturz auch im sentry (36 mal heute, 28 mal gestern, aber nur bei dir) , kann es mir aber noch nicht erklären.
                          Ich habe mal eine kleine Änderung eingebaut und auf github hochgeladen. Kannst du den Adapter von https://github.com/rg-engineering/ioBroker.semp installieren und debug-loglevel einschalten? Vielleicht sehen wir dann etwas mehr im log...

                          W 1 Reply Last reply Reply Quote 0
                          • W
                            Webwanze @Rene_HM last edited by

                            @rene_hm

                            2023-03-10 20:56:58.669 - info: host.ioBroker "system.adapter.semp.0" enabled
                            2023-03-10 20:56:58.704 - info: host.ioBroker instance system.adapter.semp.0 started with pid 52584
                            2023-03-10 20:56:59.337 - debug: semp.0 (52584) Redis Objects: Use Redis connection: 127.0.0.1:9001
                            2023-03-10 20:56:59.359 - debug: semp.0 (52584) Objects client ready ... initialize now
                            2023-03-10 20:56:59.360 - debug: semp.0 (52584) Objects create System PubSub Client
                            2023-03-10 20:56:59.361 - debug: semp.0 (52584) Objects create User PubSub Client
                            2023-03-10 20:56:59.375 - debug: semp.0 (52584) Objects client initialize lua scripts
                            2023-03-10 20:56:59.379 - debug: semp.0 (52584) Objects connected to redis: 127.0.0.1:9001
                            2023-03-10 20:56:59.390 - debug: semp.0 (52584) Redis States: Use Redis connection: 127.0.0.1:9000
                            2023-03-10 20:56:59.395 - debug: semp.0 (52584) States create System PubSub Client
                            2023-03-10 20:56:59.396 - debug: semp.0 (52584) States create User PubSub Client
                            2023-03-10 20:56:59.403 - debug: semp.0 (52584) States connected to redis: 127.0.0.1:9000
                            2023-03-10 20:56:59.428 - debug: semp.0 (52584) Plugin sentry Initialize Plugin (enabled=true)
                            2023-03-10 20:56:59.609 - info: semp.0 (52584) starting. Version 0.3.1 (non-npm: rg-engineering/ioBroker.semp#dedf941c7e0615cb00f7c78d6024a7b4a006eb1a) in /opt/iobroker/node_modules/iobroker.semp, node: v16.19.0, js-controller: 4.0.24
                            2023-03-10 20:56:59.627 - debug: semp.0 (52584) SSDPServer created: http://192.168.1.2:9765/description.xml e27c0561-11b3-47b8-a98a-006d408b0dd1
                            2023-03-10 20:56:59.632 - debug: semp.0 (52584) SEMPServer created
                            2023-03-10 20:56:59.632 - debug: semp.0 (52584) gateway created...
                            2023-03-10 20:56:59.635 - debug: semp.0 (52584) SEMP server listening on 9765
                            2023-03-10 20:56:59.638 - debug: semp.0 (52584) SSDPServer started
                            2023-03-10 20:56:59.638 - debug: semp.0 (52584) gateway started...
                            2023-03-10 20:56:59.638 - debug: semp.0 (52584) Started all!
                            2023-03-10 20:56:59.638 - debug: semp.0 (52584) add device {"IsActive":true,"ID":"F-00000000-000000000001-00","Name":"newDevice0","Vendor":"ACME","Type":"Heater","SerialNr":"1234","MaxPower":"1000","MinPower":"0","InterruptionsAllowed":false,"MinOnTime":"","MaxOnTime":"","MinOffTime":"","MaxOffTime":"","MeasurementMethod":"Measurement","OID_Power":"0_userdata.0.DEVICES.ECENTRALHEATING_P","MeasurementUnit":"W","BatteryCapacity":"","WallboxHas3phaseEnabler":false,"StatusDetection":"AlwaysOn","StatusDetectionLimit":0,"StatusDetectionLimitTimeOn":0,"StatusDetectionLimitTimeOff":0,"StatusDetectionMinRunTime":0,"OID_Status":"","HasOIDSwitch":false,"OID_Switch":"","SwitchOffAtEndOfTimer":false,"TimerActive":false,"TimerCancelIfNotOn":false,"TimerCancelIfNotOnTime":0,"EnergyRequestPeriods":[{"ID":"1","Days":"","EarliestStartTime":"","LatestEndTime":"","MinRunTime":"","MaxRunTime":""}],"WallboxOIDs":[{"active":true,"must":"obligatorisch","Name":"DeviceOIDPlugConnected","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsCharging","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsError","OID":"","Type":"Boolean","SetValue":"true"},{"active":true,"must":"obligatorisch","Name":"DeviceOIDChargePower","OID":"","Type":"Number","SetValue":"0"},{"active":false,"must":"optional","Name":"DeviceOIDStartCharge","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDStopCharge","OID":"","Type":"Boolean","SetValue":"true"}]}
                            2023-03-10 20:56:59.639 - debug: semp.0 (52584) add device F-00000000-000000000001-00
                            2023-03-10 20:56:59.640 - debug: semp.0 (52584) can use optional energy: false
                            2023-03-10 20:56:59.640 - debug: semp.0 (52584) subscribe OID_Power 0_userdata.0.DEVICES.ECENTRALHEATING_P
                            2023-03-10 20:56:59.642 - info: semp.0 (52584) device created F-00000000-000000000001-00 newDevice0
                            2023-03-10 20:56:59.643 - debug: semp.0 (52584) set device
                            2023-03-10 20:56:59.643 - debug: semp.0 (52584) newDevice0 setState On
                            2023-03-10 20:56:59.644 - debug: semp.0 (52584) UpdateData
                            2023-03-10 20:56:59.644 - debug: semp.0 (52584) device {"IsActive":true,"ID":"F-00000000-000000000001-00","Name":"newDevice0","Vendor":"ACME","Type":"Heater","SerialNr":"1234","MaxPower":"1000","MinPower":"0","InterruptionsAllowed":false,"MinOnTime":"","MaxOnTime":"","MinOffTime":"","MaxOffTime":"","MeasurementMethod":"Measurement","OID_Power":"0_userdata.0.DEVICES.ECENTRALHEATING_P","MeasurementUnit":"W","BatteryCapacity":"","WallboxHas3phaseEnabler":false,"StatusDetection":"AlwaysOn","StatusDetectionLimit":0,"StatusDetectionLimitTimeOn":0,"StatusDetectionLimitTimeOff":0,"StatusDetectionMinRunTime":0,"OID_Status":"","HasOIDSwitch":false,"OID_Switch":"","SwitchOffAtEndOfTimer":false,"TimerActive":false,"TimerCancelIfNotOn":false,"TimerCancelIfNotOnTime":0,"EnergyRequestPeriods":[{"ID":"1","Days":"","EarliestStartTime":"","LatestEndTime":"","MinRunTime":"","MaxRunTime":""}],"WallboxOIDs":[{"active":true,"must":"obligatorisch","Name":"DeviceOIDPlugConnected","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsCharging","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsError","OID":"","Type":"Boolean","SetValue":"true"},{"active":true,"must":"obligatorisch","Name":"DeviceOIDChargePower","OID":"","Type":"Number","SetValue":"0"},{"active":false,"must":"optional","Name":"DeviceOIDStartCharge","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDStopCharge","OID":"","Type":"Boolean","SetValue":"true"}],"OptionalEnergy":false}
                            2023-03-10 20:56:59.644 - debug: semp.0 (52584) result [{"ID":"1","Days":"","EarliestStartTime":"","LatestEndTime":"","MinRunTime":"","MaxRunTime":""}]
                            2023-03-10 20:56:59.644 - debug: semp.0 (52584) result [{"IsActive":true,"ID":"F-00000000-000000000001-00","Name":"newDevice0","Vendor":"ACME","Type":"Heater","SerialNr":"1234","MaxPower":"1000","MinPower":"0","InterruptionsAllowed":false,"MinOnTime":"","MaxOnTime":"","MinOffTime":"","MaxOffTime":"","MeasurementMethod":"Measurement","OID_Power":"0_userdata.0.DEVICES.ECENTRALHEATING_P","MeasurementUnit":"W","BatteryCapacity":"","WallboxHas3phaseEnabler":false,"StatusDetection":"AlwaysOn","StatusDetectionLimit":0,"StatusDetectionLimitTimeOn":0,"StatusDetectionLimitTimeOff":0,"StatusDetectionMinRunTime":0,"OID_Status":"","HasOIDSwitch":false,"OID_Switch":"","SwitchOffAtEndOfTimer":false,"TimerActive":false,"TimerCancelIfNotOn":false,"TimerCancelIfNotOnTime":0,"EnergyRequestPeriods":[{"ID":"1","Days":"","EarliestStartTime":"","LatestEndTime":"","MinRunTime":"","MaxRunTime":""}],"WallboxOIDs":[{"active":true,"must":"obligatorisch","Name":"DeviceOIDPlugConnected","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsCharging","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsError","OID":"","Type":"Boolean","SetValue":"true"},{"active":true,"must":"obligatorisch","Name":"DeviceOIDChargePower","OID":"","Type":"Number","SetValue":"0"},{"active":false,"must":"optional","Name":"DeviceOIDStartCharge","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDStopCharge","OID":"","Type":"Boolean","SetValue":"true"}],"OptionalEnergy":false}]
                            2023-03-10 20:56:59.655 - debug: semp.0 (52584) newDevice0 setLastPower 33 number AlwaysOn W
                            2023-03-10 20:56:59.658 - debug: semp.0 (52584) newDevice0 got null from Devices.newDevice0.State
                            2023-03-10 20:56:59.659 - error: semp.0 (52584) Unhandled promise rejection. This error originated either by throwing inside of an async function without a catch block, or by rejecting a promise which was not handled with .catch().
                            2023-03-10 20:56:59.659 - error: semp.0 (52584) unhandled promise rejection: Cannot read properties of null (reading 'val')
                            2023-03-10 20:56:59.663 - error: semp.0 (52584) TypeError: Cannot read properties of null (reading 'val')
                            at Device.SetState (/opt/iobroker/node_modules/iobroker.semp/lib/semp/Device.js:1052:30)
                            2023-03-10 20:56:59.663 - error: semp.0 (52584) Cannot read properties of null (reading 'val')
                            2023-03-10 20:56:59.676 - debug: semp.0 (52584) newDevice0 got null from Devices.newDevice0.State
                            2023-03-10 20:56:59.677 - error: semp.0 (52584) Unhandled promise rejection. This error originated either by throwing inside of an async function without a catch block, or by rejecting a promise which was not handled with .catch().
                            2023-03-10 20:56:59.677 - error: semp.0 (52584) unhandled promise rejection: Cannot read properties of null (reading 'val')
                            2023-03-10 20:56:59.678 - error: semp.0 (52584) TypeError: Cannot read properties of null (reading 'val')
                            at Device.SetState (/opt/iobroker/node_modules/iobroker.semp/lib/semp/Device.js:1052:30)
                            at runNextTicks (node:internal/process/task_queues:61:5)
                            at processImmediate (node:internal/timers:437:9)
                            2023-03-10 20:56:59.679 - error: semp.0 (52584) Cannot read properties of null (reading 'val')
                            2023-03-10 20:56:59.683 - debug: semp.0 (52584) delete all devices
                            2023-03-10 20:56:59.683 - debug: semp.0 (52584) SEMP server stopped
                            2023-03-10 20:56:59.684 - info: semp.0 (52584) terminating
                            2023-03-10 20:56:59.685 - debug: semp.0 (52584) Plugin sentry destroyed
                            2023-03-10 20:56:59.685 - warn: semp.0 (52584) Terminated (UNCAUGHT_EXCEPTION): Without reason
                            2023-03-10 20:56:59.689 - debug: semp.0 (52584) SSDPServer stopped
                            2023-03-10 20:56:59.689 - debug: semp.0 (52584) gateway stopped...
                            2023-03-10 20:57:00.225 - error: host.ioBroker Caught by controller[0]: This error originated either by throwing inside of an async function without a catch block, or by rejecting a promise which was not handled with .catch(). The promise rejected with the reason:
                            2023-03-10 20:57:00.226 - error: host.ioBroker Caught by controller[1]: TypeError: Cannot read properties of null (reading 'val')
                            2023-03-10 20:57:00.226 - error: host.ioBroker Caught by controller[1]: at Device.SetState (/opt/iobroker/node_modules/iobroker.semp/lib/semp/Device.js:1052:30)
                            2023-03-10 20:57:00.226 - error: host.ioBroker Caught by controller[2]: This error originated either by throwing inside of an async function without a catch block, or by rejecting a promise which was not handled with .catch(). The promise rejected with the reason:
                            2023-03-10 20:57:00.226 - error: host.ioBroker Caught by controller[2]: TypeError: Cannot read properties of null (reading 'val')
                            2023-03-10 20:57:00.226 - error: host.ioBroker Caught by controller[2]: at Device.SetState (/opt/iobroker/node_modules/iobroker.semp/lib/semp/Device.js:1052:30)
                            2023-03-10 20:57:00.226 - error: host.ioBroker Caught by controller[2]: at runNextTicks (node:internal/process/task_queues:61:5)
                            2023-03-10 20:57:00.226 - error: host.ioBroker Caught by controller[2]: at processImmediate (node:internal/timers:437:9)
                            2023-03-10 20:57:00.226 - error: host.ioBroker instance system.adapter.semp.0 terminated with code 6 (UNCAUGHT_EXCEPTION)
                            2023-03-10 20:57:00.226 - info: host.ioBroker Restart adapter system.adapter.semp.0 because enabled
                            2023-03-10 20:57:30.259 - info: host.ioBroker instance system.adapter.semp.0 started with pid 52599
                            2023-03-10 20:57:30.854 - debug: semp.0 (52599) Redis Objects: Use Redis connection: 127.0.0.1:9001
                            2023-03-10 20:57:30.877 - debug: semp.0 (52599) Objects client ready ... initialize now
                            2023-03-10 20:57:30.878 - debug: semp.0 (52599) Objects create System PubSub Client
                            2023-03-10 20:57:30.879 - debug: semp.0 (52599) Objects create User PubSub Client
                            2023-03-10 20:57:30.895 - debug: semp.0 (52599) Objects client initialize lua scripts
                            2023-03-10 20:57:30.898 - debug: semp.0 (52599) Objects connected to redis: 127.0.0.1:9001
                            2023-03-10 20:57:30.911 - debug: semp.0 (52599) Redis States: Use Redis connection: 127.0.0.1:9000
                            2023-03-10 20:57:30.916 - debug: semp.0 (52599) States create System PubSub Client
                            2023-03-10 20:57:30.917 - debug: semp.0 (52599) States create User PubSub Client
                            2023-03-10 20:57:30.925 - debug: semp.0 (52599) States connected to redis: 127.0.0.1:9000
                            2023-03-10 20:57:30.948 - debug: semp.0 (52599) Plugin sentry Initialize Plugin (enabled=true)
                            2023-03-10 20:57:31.103 - info: semp.0 (52599) starting. Version 0.3.1 (non-npm: rg-engineering/ioBroker.semp#dedf941c7e0615cb00f7c78d6024a7b4a006eb1a) in /opt/iobroker/node_modules/iobroker.semp, node: v16.19.0, js-controller: 4.0.24
                            2023-03-10 20:57:31.121 - debug: semp.0 (52599) SSDPServer created: http://192.168.1.2:9765/description.xml e27c0561-11b3-47b8-a98a-006d408b0dd1
                            2023-03-10 20:57:31.125 - debug: semp.0 (52599) SEMPServer created
                            2023-03-10 20:57:31.126 - debug: semp.0 (52599) gateway created...
                            2023-03-10 20:57:31.129 - debug: semp.0 (52599) SEMP server listening on 9765
                            2023-03-10 20:57:31.132 - debug: semp.0 (52599) SSDPServer started
                            2023-03-10 20:57:31.132 - debug: semp.0 (52599) gateway started...
                            2023-03-10 20:57:31.132 - debug: semp.0 (52599) Started all!
                            2023-03-10 20:57:31.132 - debug: semp.0 (52599) add device {"IsActive":true,"ID":"F-00000000-000000000001-00","Name":"newDevice0","Vendor":"ACME","Type":"Heater","SerialNr":"1234","MaxPower":"1000","MinPower":"0","InterruptionsAllowed":false,"MinOnTime":"","MaxOnTime":"","MinOffTime":"","MaxOffTime":"","MeasurementMethod":"Measurement","OID_Power":"0_userdata.0.DEVICES.ECENTRALHEATING_P","MeasurementUnit":"W","BatteryCapacity":"","WallboxHas3phaseEnabler":false,"StatusDetection":"AlwaysOn","StatusDetectionLimit":0,"StatusDetectionLimitTimeOn":0,"StatusDetectionLimitTimeOff":0,"StatusDetectionMinRunTime":0,"OID_Status":"","HasOIDSwitch":false,"OID_Switch":"","SwitchOffAtEndOfTimer":false,"TimerActive":false,"TimerCancelIfNotOn":false,"TimerCancelIfNotOnTime":0,"EnergyRequestPeriods":[{"ID":"1","Days":"","EarliestStartTime":"","LatestEndTime":"","MinRunTime":"","MaxRunTime":""}],"WallboxOIDs":[{"active":true,"must":"obligatorisch","Name":"DeviceOIDPlugConnected","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsCharging","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsError","OID":"","Type":"Boolean","SetValue":"true"},{"active":true,"must":"obligatorisch","Name":"DeviceOIDChargePower","OID":"","Type":"Number","SetValue":"0"},{"active":false,"must":"optional","Name":"DeviceOIDStartCharge","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDStopCharge","OID":"","Type":"Boolean","SetValue":"true"}]}
                            2023-03-10 20:57:31.133 - debug: semp.0 (52599) add device F-00000000-000000000001-00
                            2023-03-10 20:57:31.134 - debug: semp.0 (52599) can use optional energy: false
                            2023-03-10 20:57:31.134 - debug: semp.0 (52599) subscribe OID_Power 0_userdata.0.DEVICES.ECENTRALHEATING_P
                            2023-03-10 20:57:31.136 - info: semp.0 (52599) device created F-00000000-000000000001-00 newDevice0
                            2023-03-10 20:57:31.137 - debug: semp.0 (52599) set device
                            2023-03-10 20:57:31.137 - debug: semp.0 (52599) newDevice0 setState On
                            2023-03-10 20:57:31.137 - debug: semp.0 (52599) UpdateData
                            2023-03-10 20:57:31.138 - debug: semp.0 (52599) device {"IsActive":true,"ID":"F-00000000-000000000001-00","Name":"newDevice0","Vendor":"ACME","Type":"Heater","SerialNr":"1234","MaxPower":"1000","MinPower":"0","InterruptionsAllowed":false,"MinOnTime":"","MaxOnTime":"","MinOffTime":"","MaxOffTime":"","MeasurementMethod":"Measurement","OID_Power":"0_userdata.0.DEVICES.ECENTRALHEATING_P","MeasurementUnit":"W","BatteryCapacity":"","WallboxHas3phaseEnabler":false,"StatusDetection":"AlwaysOn","StatusDetectionLimit":0,"StatusDetectionLimitTimeOn":0,"StatusDetectionLimitTimeOff":0,"StatusDetectionMinRunTime":0,"OID_Status":"","HasOIDSwitch":false,"OID_Switch":"","SwitchOffAtEndOfTimer":false,"TimerActive":false,"TimerCancelIfNotOn":false,"TimerCancelIfNotOnTime":0,"EnergyRequestPeriods":[{"ID":"1","Days":"","EarliestStartTime":"","LatestEndTime":"","MinRunTime":"","MaxRunTime":""}],"WallboxOIDs":[{"active":true,"must":"obligatorisch","Name":"DeviceOIDPlugConnected","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsCharging","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsError","OID":"","Type":"Boolean","SetValue":"true"},{"active":true,"must":"obligatorisch","Name":"DeviceOIDChargePower","OID":"","Type":"Number","SetValue":"0"},{"active":false,"must":"optional","Name":"DeviceOIDStartCharge","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDStopCharge","OID":"","Type":"Boolean","SetValue":"true"}],"OptionalEnergy":false}
                            2023-03-10 20:57:31.138 - debug: semp.0 (52599) result [{"ID":"1","Days":"","EarliestStartTime":"","LatestEndTime":"","MinRunTime":"","MaxRunTime":""}]
                            2023-03-10 20:57:31.138 - debug: semp.0 (52599) result [{"IsActive":true,"ID":"F-00000000-000000000001-00","Name":"newDevice0","Vendor":"ACME","Type":"Heater","SerialNr":"1234","MaxPower":"1000","MinPower":"0","InterruptionsAllowed":false,"MinOnTime":"","MaxOnTime":"","MinOffTime":"","MaxOffTime":"","MeasurementMethod":"Measurement","OID_Power":"0_userdata.0.DEVICES.ECENTRALHEATING_P","MeasurementUnit":"W","BatteryCapacity":"","WallboxHas3phaseEnabler":false,"StatusDetection":"AlwaysOn","StatusDetectionLimit":0,"StatusDetectionLimitTimeOn":0,"StatusDetectionLimitTimeOff":0,"StatusDetectionMinRunTime":0,"OID_Status":"","HasOIDSwitch":false,"OID_Switch":"","SwitchOffAtEndOfTimer":false,"TimerActive":false,"TimerCancelIfNotOn":false,"TimerCancelIfNotOnTime":0,"EnergyRequestPeriods":[{"ID":"1","Days":"","EarliestStartTime":"","LatestEndTime":"","MinRunTime":"","MaxRunTime":""}],"WallboxOIDs":[{"active":true,"must":"obligatorisch","Name":"DeviceOIDPlugConnected","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsCharging","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsError","OID":"","Type":"Boolean","SetValue":"true"},{"active":true,"must":"obligatorisch","Name":"DeviceOIDChargePower","OID":"","Type":"Number","SetValue":"0"},{"active":false,"must":"optional","Name":"DeviceOIDStartCharge","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDStopCharge","OID":"","Type":"Boolean","SetValue":"true"}],"OptionalEnergy":false}]
                            2023-03-10 20:57:31.148 - debug: semp.0 (52599) newDevice0 setLastPower 33 number AlwaysOn W
                            2023-03-10 20:57:31.150 - debug: semp.0 (52599) newDevice0 got null from Devices.newDevice0.State
                            2023-03-10 20:57:31.151 - error: semp.0 (52599) Unhandled promise rejection. This error originated either by throwing inside of an async function without a catch block, or by rejecting a promise which was not handled with .catch().
                            2023-03-10 20:57:31.151 - error: semp.0 (52599) unhandled promise rejection: Cannot read properties of null (reading 'val')
                            2023-03-10 20:57:31.154 - error: semp.0 (52599) TypeError: Cannot read properties of null (reading 'val')
                            at Device.SetState (/opt/iobroker/node_modules/iobroker.semp/lib/semp/Device.js:1052:30)
                            2023-03-10 20:57:31.154 - error: semp.0 (52599) Cannot read properties of null (reading 'val')
                            2023-03-10 20:57:31.166 - debug: semp.0 (52599) newDevice0 got null from Devices.newDevice0.State
                            2023-03-10 20:57:31.166 - error: semp.0 (52599) Unhandled promise rejection. This error originated either by throwing inside of an async function without a catch block, or by rejecting a promise which was not handled with .catch().
                            2023-03-10 20:57:31.166 - error: semp.0 (52599) unhandled promise rejection: Cannot read properties of null (reading 'val')
                            2023-03-10 20:57:31.167 - error: semp.0 (52599) TypeError: Cannot read properties of null (reading 'val')
                            at Device.SetState (/opt/iobroker/node_modules/iobroker.semp/lib/semp/Device.js:1052:30)
                            at runNextTicks (node:internal/process/task_queues:61:5)
                            at processImmediate (node:internal/timers:437:9)
                            2023-03-10 20:57:31.168 - error: semp.0 (52599) Cannot read properties of null (reading 'val')
                            2023-03-10 20:57:31.171 - debug: semp.0 (52599) delete all devices
                            2023-03-10 20:57:31.171 - debug: semp.0 (52599) SEMP server stopped
                            2023-03-10 20:57:31.172 - info: semp.0 (52599) terminating
                            2023-03-10 20:57:31.172 - debug: semp.0 (52599) Plugin sentry destroyed
                            2023-03-10 20:57:31.172 - warn: semp.0 (52599) Terminated (UNCAUGHT_EXCEPTION): Without reason
                            2023-03-10 20:57:31.175 - debug: semp.0 (52599) SSDPServer stopped
                            2023-03-10 20:57:31.176 - debug: semp.0 (52599) gateway stopped...
                            2023-03-10 20:57:31.720 - error: host.ioBroker Caught by controller[0]: This error originated either by throwing inside of an async function without a catch block, or by rejecting a promise which was not handled with .catch(). The promise rejected with the reason:
                            2023-03-10 20:57:31.720 - error: host.ioBroker Caught by controller[1]: TypeError: Cannot read properties of null (reading 'val')
                            2023-03-10 20:57:31.720 - error: host.ioBroker Caught by controller[1]: at Device.SetState (/opt/iobroker/node_modules/iobroker.semp/lib/semp/Device.js:1052:30)
                            2023-03-10 20:57:31.720 - error: host.ioBroker Caught by controller[2]: This error originated either by throwing inside of an async function without a catch block, or by rejecting a promise which was not handled with .catch(). The promise rejected with the reason:
                            2023-03-10 20:57:31.720 - error: host.ioBroker Caught by controller[2]: TypeError: Cannot read properties of null (reading 'val')
                            2023-03-10 20:57:31.720 - error: host.ioBroker Caught by controller[2]: at Device.SetState (/opt/iobroker/node_modules/iobroker.semp/lib/semp/Device.js:1052:30)
                            2023-03-10 20:57:31.720 - error: host.ioBroker Caught by controller[2]: at runNextTicks (node:internal/process/task_queues:61:5)
                            2023-03-10 20:57:31.720 - error: host.ioBroker Caught by controller[2]: at processImmediate (node:internal/timers:437:9)
                            2023-03-10 20:57:31.720 - error: host.ioBroker instance system.adapter.semp.0 terminated with code 6 (UNCAUGHT_EXCEPTION)
                            2023-03-10 20:57:31.721 - info: host.ioBroker Restart adapter system.adapter.semp.0 because enabled
                            
                            
                            Rene_HM 1 Reply Last reply Reply Quote 0
                            • Rene_HM
                              Rene_HM Developer @Webwanze last edited by

                              @webwanze Das log sieht eigentlich gut aus, trotzdem funktioniert das ganze bei dir nicht. 😞
                              Ich habe nochmal ein paar logs hinzugefügt. Kannst du bitte nochmal von github (wie oben) installieren?

                              W 1 Reply Last reply Reply Quote 0
                              • W
                                Webwanze @Rene_HM last edited by

                                @rene_hm

                                Hallo,

                                die Instanz wird jetzt grün:

                                2023-03-11 09:55:55.393 - info: host.ioBroker "system.adapter.semp.0" enabled
                                2023-03-11 09:55:55.426 - info: host.ioBroker instance system.adapter.semp.0 started with pid 53629
                                2023-03-11 09:55:56.057 - debug: semp.0 (53629) Redis Objects: Use Redis connection: 127.0.0.1:9001
                                2023-03-11 09:55:56.076 - debug: semp.0 (53629) Objects client ready ... initialize now
                                2023-03-11 09:55:56.078 - debug: semp.0 (53629) Objects create System PubSub Client
                                2023-03-11 09:55:56.078 - debug: semp.0 (53629) Objects create User PubSub Client
                                2023-03-11 09:55:56.099 - debug: semp.0 (53629) Objects client initialize lua scripts
                                2023-03-11 09:55:56.103 - debug: semp.0 (53629) Objects connected to redis: 127.0.0.1:9001
                                2023-03-11 09:55:56.114 - debug: semp.0 (53629) Redis States: Use Redis connection: 127.0.0.1:9000
                                2023-03-11 09:55:56.120 - debug: semp.0 (53629) States create System PubSub Client
                                2023-03-11 09:55:56.121 - debug: semp.0 (53629) States create User PubSub Client
                                2023-03-11 09:55:56.128 - debug: semp.0 (53629) States connected to redis: 127.0.0.1:9000
                                2023-03-11 09:55:56.154 - debug: semp.0 (53629) Plugin sentry Initialize Plugin (enabled=true)
                                2023-03-11 09:55:56.299 - info: semp.0 (53629) starting. Version 0.3.1 (non-npm: rg-engineering/ioBroker.semp#6225ab9cb4be90b2b25f1f20179f6e884e287309) in /opt/iobroker/node_modules/iobroker.semp, node: v16.19.0, js-controller: 4.0.24
                                2023-03-11 09:55:56.317 - debug: semp.0 (53629) SSDPServer created: http://192.168.1.2:9765/description.xml ba7895e3-74c6-47ee-a912-e544105b6f50
                                2023-03-11 09:55:56.322 - debug: semp.0 (53629) SEMPServer created
                                2023-03-11 09:55:56.322 - debug: semp.0 (53629) gateway created...
                                2023-03-11 09:55:56.325 - debug: semp.0 (53629) SEMP server listening on 9765
                                2023-03-11 09:55:56.328 - debug: semp.0 (53629) SSDPServer started
                                2023-03-11 09:55:56.328 - debug: semp.0 (53629) gateway started...
                                2023-03-11 09:55:56.328 - debug: semp.0 (53629) Started all!
                                2023-03-11 09:55:56.328 - debug: semp.0 (53629) add device {"IsActive":true,"ID":"F-0-000000000001-00","Name":"newDevice0","Vendor":"ACME","Type":"Heater","SerialNr":"1234","MaxPower":"1000","MinPower":"0","InterruptionsAllowed":false,"MinOnTime":"","MaxOnTime":"","MinOffTime":"","MaxOffTime":"","MeasurementMethod":"Measurement","OID_Power":"0_userdata.0.DEVICES.ECENTRALHEATING_P","MeasurementUnit":"W","BatteryCapacity":"","WallboxHas3phaseEnabler":false,"StatusDetection":"AlwaysOn","StatusDetectionLimit":0,"StatusDetectionLimitTimeOn":0,"StatusDetectionLimitTimeOff":0,"StatusDetectionMinRunTime":0,"OID_Status":"","HasOIDSwitch":false,"OID_Switch":"","SwitchOffAtEndOfTimer":false,"TimerActive":false,"TimerCancelIfNotOn":false,"TimerCancelIfNotOnTime":0,"EnergyRequestPeriods":[{"ID":"1","Days":"","EarliestStartTime":"","LatestEndTime":"","MinRunTime":"","MaxRunTime":""}],"WallboxOIDs":[{"active":true,"must":"obligatorisch","Name":"DeviceOIDPlugConnected","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsCharging","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsError","OID":"","Type":"Boolean","SetValue":"true"},{"active":true,"must":"obligatorisch","Name":"DeviceOIDChargePower","OID":"","Type":"Number","SetValue":"0"},{"active":false,"must":"optional","Name":"DeviceOIDStartCharge","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDStopCharge","OID":"","Type":"Boolean","SetValue":"true"}]}
                                2023-03-11 09:55:56.329 - debug: semp.0 (53629) add device F-0-000000000001-00
                                2023-03-11 09:55:56.330 - error: semp.0 (53629) newDevice0 wrong device id F-0-000000000001-00! must follow F-xxxxxxxx-yyyyyyyyyyyy-zz
                                2023-03-11 09:55:56.330 - debug: semp.0 (53629) can use optional energy: false
                                2023-03-11 09:55:56.330 - debug: semp.0 (53629) subscribe OID_Power 0_userdata.0.DEVICES.ECENTRALHEATING_P
                                2023-03-11 09:55:56.332 - info: semp.0 (53629) device created F-0-000000000001-00 newDevice0
                                2023-03-11 09:55:56.333 - debug: semp.0 (53629) set device
                                2023-03-11 09:55:56.333 - debug: semp.0 (53629) newDevice0 setState On
                                2023-03-11 09:55:56.334 - debug: semp.0 (53629) UpdateData
                                2023-03-11 09:55:56.334 - debug: semp.0 (53629) device {"IsActive":true,"ID":"F-0-000000000001-00","Name":"newDevice0","Vendor":"ACME","Type":"Heater","SerialNr":"1234","MaxPower":"1000","MinPower":"0","InterruptionsAllowed":false,"MinOnTime":"","MaxOnTime":"","MinOffTime":"","MaxOffTime":"","MeasurementMethod":"Measurement","OID_Power":"0_userdata.0.DEVICES.ECENTRALHEATING_P","MeasurementUnit":"W","BatteryCapacity":"","WallboxHas3phaseEnabler":false,"StatusDetection":"AlwaysOn","StatusDetectionLimit":0,"StatusDetectionLimitTimeOn":0,"StatusDetectionLimitTimeOff":0,"StatusDetectionMinRunTime":0,"OID_Status":"","HasOIDSwitch":false,"OID_Switch":"","SwitchOffAtEndOfTimer":false,"TimerActive":false,"TimerCancelIfNotOn":false,"TimerCancelIfNotOnTime":0,"EnergyRequestPeriods":[{"ID":"1","Days":"","EarliestStartTime":"","LatestEndTime":"","MinRunTime":"","MaxRunTime":""}],"WallboxOIDs":[{"active":true,"must":"obligatorisch","Name":"DeviceOIDPlugConnected","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsCharging","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsError","OID":"","Type":"Boolean","SetValue":"true"},{"active":true,"must":"obligatorisch","Name":"DeviceOIDChargePower","OID":"","Type":"Number","SetValue":"0"},{"active":false,"must":"optional","Name":"DeviceOIDStartCharge","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDStopCharge","OID":"","Type":"Boolean","SetValue":"true"}],"OptionalEnergy":false}
                                2023-03-11 09:55:56.334 - debug: semp.0 (53629) result [{"ID":"1","Days":"","EarliestStartTime":"","LatestEndTime":"","MinRunTime":"","MaxRunTime":""}]
                                2023-03-11 09:55:56.334 - debug: semp.0 (53629) result [{"IsActive":true,"ID":"F-0-000000000001-00","Name":"newDevice0","Vendor":"ACME","Type":"Heater","SerialNr":"1234","MaxPower":"1000","MinPower":"0","InterruptionsAllowed":false,"MinOnTime":"","MaxOnTime":"","MinOffTime":"","MaxOffTime":"","MeasurementMethod":"Measurement","OID_Power":"0_userdata.0.DEVICES.ECENTRALHEATING_P","MeasurementUnit":"W","BatteryCapacity":"","WallboxHas3phaseEnabler":false,"StatusDetection":"AlwaysOn","StatusDetectionLimit":0,"StatusDetectionLimitTimeOn":0,"StatusDetectionLimitTimeOff":0,"StatusDetectionMinRunTime":0,"OID_Status":"","HasOIDSwitch":false,"OID_Switch":"","SwitchOffAtEndOfTimer":false,"TimerActive":false,"TimerCancelIfNotOn":false,"TimerCancelIfNotOnTime":0,"EnergyRequestPeriods":[{"ID":"1","Days":"","EarliestStartTime":"","LatestEndTime":"","MinRunTime":"","MaxRunTime":""}],"WallboxOIDs":[{"active":true,"must":"obligatorisch","Name":"DeviceOIDPlugConnected","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsCharging","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDIsError","OID":"","Type":"Boolean","SetValue":"true"},{"active":true,"must":"obligatorisch","Name":"DeviceOIDChargePower","OID":"","Type":"Number","SetValue":"0"},{"active":false,"must":"optional","Name":"DeviceOIDStartCharge","OID":"","Type":"Boolean","SetValue":"true"},{"active":false,"must":"optional","Name":"DeviceOIDStopCharge","OID":"","Type":"Boolean","SetValue":"true"}],"OptionalEnergy":false}]
                                2023-03-11 09:55:56.348 - debug: semp.0 (53629) newDevice0 setLastPower 117 number AlwaysOn W
                                2023-03-11 09:55:56.350 - debug: semp.0 (53629) newDevice0 got null from Devices.newDevice0.State
                                2023-03-11 09:55:56.351 - error: semp.0 (53629) newDevice0 could not set state waiting on Devices.newDevice0.State
                                2023-03-11 09:55:56.354 - debug: semp.0 (53629) newDevice0 got null from Devices.newDevice0.State
                                2023-03-11 09:55:56.355 - error: semp.0 (53629) newDevice0 could not set state on on Devices.newDevice0.State
                                2023-03-11 09:55:56.357 - debug: semp.0 (53629) newDevice0 got object {"type":"state","common":{"name":"recommended state from SHM","type":"boolean","role":"state","read":true,"write":false},"from":"system.adapter.semp.0","user":"system.user.admin","ts":1678524926725,"_id":"semp.0.Devices.newDevice0.RecommendedState","acl":{"object":1636,"state":1636,"owner":"system.user.admin","ownerGroup":"system.group.administrator"}}
                                2023-03-11 09:55:56.381 - debug: semp.0 (53629) newDevice0 got object {"type":"state","common":{"name":"last time recommendation changed","type":"string","role":"value.time","read":true,"write":false},"from":"system.adapter.semp.0","user":"system.user.admin","ts":1678524926734,"_id":"semp.0.Devices.newDevice0.Changed","acl":{"object":1636,"state":1636,"owner":"system.user.admin","ownerGroup":"system.group.administrator"}}
                                2023-03-11 09:55:56.385 - debug: semp.0 (53629) newDevice0 got object {"type":"state","common":{"name":"current State","type":"string","role":"state","read":true,"write":false},"from":"system.adapter.semp.0","user":"system.user.admin","ts":1678524926738,"_id":"semp.0.Devices.newDevice0.State","acl":{"object":1636,"state":1636,"owner":"system.user.admin","ownerGroup":"system.group.administrator"}}
                                2023-03-11 09:55:56.386 - debug: semp.0 (53629) newDevice0 got object {"type":"state","common":{"name":"Energy used","type":"number","unit":"Wh","role":"value","read":true,"write":false},"from":"system.adapter.semp.0","user":"system.user.admin","ts":1678524926744,"_id":"semp.0.Devices.newDevice0.Energy","acl":{"object":1636,"state":1636,"owner":"system.user.admin","ownerGroup":"system.group.administrator"}}
                                2023-03-11 09:55:59.376 - debug: semp.0 (53629) SHM requested description
                                2023-03-11 09:55:59.377 - info: semp.0 (53629) adapter discovered by SHM
                                2023-03-11 09:56:00.033 - debug: semp.0 (53629) newDevice0 setLastPower 117 number AlwaysOn W
                                2023-03-11 09:56:00.033 - debug: semp.0 (53629) newDevice0 calc energy 117 1678524956349 = 0.11973000000000002Wh
                                2023-03-11 09:56:15.007 - debug: semp.0 (53629) newDevice0 setLastPower 117 number AlwaysOn W
                                2023-03-11 09:56:15.008 - debug: semp.0 (53629) newDevice0 calc energy 117 1678524960033 = 0.6064175Wh
                                2023-03-11 09:56:16.376 - debug: semp.0 (53629) SHM requested description
                                2023-03-11 09:56:30.009 - debug: semp.0 (53629) newDevice0 setLastPower 117 number AlwaysOn W
                                2023-03-11 09:56:30.009 - debug: semp.0 (53629) newDevice0 calc energy 117 1678524975008 = 1.09395Wh
                                2023-03-11 09:56:36.377 - debug: semp.0 (53629) SHM requested description
                                2023-03-11 09:56:45.007 - debug: semp.0 (53629) newDevice0 setLastPower 122 number AlwaysOn W
                                2023-03-11 09:56:45.007 - debug: semp.0 (53629) newDevice0 calc energy 122 1678524990009 = 1.6022155555555555Wh
                                

                                Bei den Objekten finden sich immer noch die (null)s.
                                f3090048-628d-42bf-99fa-207a54ed335f-grafik.png

                                Danke für deine Unterstützung!!!

                                Rene_HM 1 Reply Last reply Reply Quote 0
                                • Rene_HM
                                  Rene_HM Developer @Webwanze last edited by Rene_HM

                                  @webwanze sagte in Adapter: SMA SEMP:

                                  error: semp.0 (53629) newDevice0 could not set state waiting on Devices.newDevice0.State

                                  Der Fehler ist noch nicht behoben, nur ignoriert. Ich schaue das log nochmal genauer an. Irgendetwas passt noch nicht...

                                  newDevice0 wrong device id F-0-000000000001-00! must follow F-xxxxxxxx-yyyyyyyyyyyy-zz

                                  und den Fehler darfst du auch nicht ignorieren...

                                  W 1 Reply Last reply Reply Quote 0
                                  • W
                                    Webwanze @Rene_HM last edited by

                                    @rene_hm sagte in Adapter: SMA SEMP:

                                    newDevice0 wrong device id F-0-000000000001-00! must follow F-xxxxxxxx-yyyyyyyyyyyy-zz

                                    und den Fehler darfst du auch nicht ignorieren...

                                    Ich habe da nichts geändert. Die ID wurde beim Hinzufügen des Devices automatisch generiert. Habe es aber jetzt mal geändert. Macht natürlich keinen Unterschied.

                                    Über Java-Script
                                    setState("semp.0.Devices.newDevice0.State", "test")
                                    kann ich den State übrigens ändern.

                                    Rene_HM 1 Reply Last reply Reply Quote 0
                                    • Rene_HM
                                      Rene_HM Developer @Webwanze last edited by

                                      @webwanze sagte in Adapter: SMA SEMP:

                                      Macht natürlich keinen Unterschied.

                                      für o.g. Problem macht es keinen Unterschied, funktionell ist das wichtig.

                                      W 1 Reply Last reply Reply Quote 0
                                      • W
                                        Webwanze @Rene_HM last edited by Webwanze

                                        @rene_hm
                                        Ich habe noch etwas herumgespielt und auch was herausgefunden:

                                        Adapter installieren
                                        Device anlegen
                                        -> kein Update State

                                        Host neu starten
                                        -> kein Update State

                                        State von Hand oder Script ändern
                                        -> Fehler verschwunden, allerdings wird mein String "test" nicht upgedated
                                        -> ich nehme an, weil sich der State für die Instanz nicht geändert hat, erfolgt kein Update. OK.

                                        Instanz neu starten
                                        -> Alles i.O.
                                        -> State wird auf "on" gesetzt.

                                        W 1 Reply Last reply Reply Quote 0
                                        • W
                                          Webwanze @Webwanze last edited by Webwanze

                                          Wenn ich nun ein weiteres Device hinzufüge, wird der State ebenfalls nicht upgedated.
                                          State von Hand auf z.B. "off" setzen.
                                          Instanz neu starten

                                          funktioniert.

                                          Die Were für "Changed" und "RecommendedState" werden übrigens nicht gesetzt. Evtl. wird das auch nicht von der Instanz versucht ...

                                          Rene_HM 2 Replies Last reply Reply Quote 0
                                          • Rene_HM
                                            Rene_HM Developer @Webwanze last edited by

                                            @webwanze sagte in Adapter: SMA SEMP:

                                            Die Werte für "Changed" und "RecommendedState" werden übrigens nicht gesetzt

                                            Die werden erst gesetzt, wenn eine Energieanforderung vom SHM beantwortet wurde. Solange du dein Gerät auf "immer an" hast und keine Energieanforderung stellst, reagiert der SHM nicht. Das Gerät wird dann nur im Portal dargestellt und zur Berechnung der Prognose herangezogen...

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate
                                            FAQ Cloud / IOT
                                            HowTo: Node.js-Update
                                            HowTo: Backup/Restore
                                            Downloads
                                            BLOG

                                            1.0k
                                            Online

                                            31.6k
                                            Users

                                            79.4k
                                            Topics

                                            1.3m
                                            Posts

                                            25
                                            232
                                            24080
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo