    3. Tester
    4. [Aufruf] TP-Link HS100 HS110 Adapter Testen

    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    [Aufruf] TP-Link HS100 HS110 Adapter Testen

    This topic has been deleted. Only users with topic management privileges can see it.
    • N
      Nebulus last edited by

      Dieser Button fehlt bei mir
      1191_1.jpg

      1 Reply Last reply Reply Quote 0
      • F
        FixMax0815 last edited by

        Hallo

        Ich muss nochmal ganz blöd fragen wie das geht. :?: :?:

        Kann mir jemand eine Erklärung für Anfänger geben.

        Ich betreibe das ganze auf einem Win10 Rechner.

        Danke im voraus.

        1 Reply Last reply Reply Quote 0
        • apollon77
          apollon77 last edited by

          @arteck: Baust Du das Adapter-testing bitte noch ein? ktiviert in Travis-CI ist es ja schon 🙂

          1 Reply Last reply Reply Quote 0
          • arteck
            arteck Developer Most Active last edited by

            @apollon77:

            @arteck: Baust Du das Adapter-testing bitte noch ein? ktiviert in Travis-CI ist es ja schon 🙂 `

            klar muss nur die Zeit zu finden… :shock:

            @FixMax0815:

            Hallo

            Ich muss nochmal ganz blöd fragen wie das geht. :?: :?:

            Kann mir jemand eine Erklärung für Anfänger geben.

            Ich betreibe das ganze auf einem Win10 Rechner.

            Danke im voraus. `

            cmd auf

            in den installations ordner vom iobroker wechseln

            npm install iobroker.hs100

            danach müsste der Adapter in der Auflist ercheinen

            1 Reply Last reply Reply Quote 0
            • F
              FixMax0815 last edited by

              Hallo

              Habe den Adapter zum laufen gebracht. (dank eurer Hilfe)

              Habe auch die IP Adressen eingegeben von meinen Steckdosen.

              Die Steuerung über dem ioBroker hat auch funktioniert.

              Nun meine Problem!!

              Ich habe die IP Adressen in meiner Fritzbox fix vergeben, aber nach dem sich die Steckdosen neu verbinden

              bekommen sie immer eine neu IP und ich kann sie nicht steuern.

              Kann mir da wer sagen was ich falsch mache??

              Danke

              1 Reply Last reply Reply Quote 0
              • arteck
                arteck Developer Most Active last edited by

                natürlich müssen die Steckdosen feste IP im Router bekommen. sonst geht es nicht.. iobroker hat kein einfluss auf den Router..

                Ich würde mal sagen da stimmt was mit der Fritzbox konfiguration nicht.

                hast du den Wertebereich ausserhalb des dhcp Bereiches (falls du diesen auch am laufen hast) angegeben ??

                ich habe in meiner 7490 auf Feste IP's für bestimmte Geräte .. schau nochmal nach .. die Dosen müssen in der Fritzdose fest sein und IMMER die gleiche IP bekommen

                1 Reply Last reply Reply Quote 0
                • ?
                  A Former User last edited by

                  Hallo @ All

                  Adapter erfolgreich installiert.

                  Kann mir jemand sagen wie ich die Verbrauchsdaten mit iobroker angezeigt bekomme?

                  Grüße Pocky 🙂

                  1 Reply Last reply Reply Quote 0
                  • M
                    muckel last edited by

                    Hallo Arteck

                    Kannst du mir dazu einen Tip geben.

                    Danke im Voraus

                    liebe Grüße

                    host.iobroker	2017-09-12 17:59:22.814	info	Restart adapter system.adapter.hs100.0 because enabled
                    host.iobroker	2017-09-12 17:59:22.813	error	instance system.adapter.hs100.0 terminated with code 0 (OK)
                    hs100.0	2017-09-12 17:59:22.313	error	TypeError: Cannot read property 'length' of undefined at main (/opt/iobroker/node_modules/iobroker.hs100/main.js:377:32) at Adapter. (/opt/iobroker/node_modules/iobroker.hs100/main.
                    hs100.0	2017-09-12 17:59:22.313	error	uncaught exception: Cannot read property 'length' of undefined
                    hs100.0	2017-09-12 17:59:22.311	info	starting. Version 0.0.16 in /opt/iobroker/node_modules/iobroker.hs100, node: v4.7.2
                    host.iobroker	2017-09-12 17:59:20.913	info	instance system.adapter.hs100.0 started with pid 768
                    host.iobroker	2017-09-12 17:58:50.869	info	Restart adapter system.adapter.hs100.0 because enabled
                    host.iobroker	2017-09-12 17:58:50.869	error	instance system.adapter.hs100.0 terminated with code 0 (OK)
                    hs100.0	2017-09-12 17:58:50.369	error	TypeError: Cannot read property 'length' of undefined at main (/opt/iobroker/node_modules/iobroker.hs100/main.js:377:32) at Adapter. (/opt/iobroker/node_modules/iobroker.hs100/main.
                    hs100.0	2017-09-12 17:58:50.368	error	uncaught exception: Cannot read property 'length' of undefined
                    hs100.0	2017-09-12 17:58:50.367	info	starting. Version 0.0.16 in /opt/iobroker/node_modules/iobroker.hs100, node: v4.7.2
                    host.iobroker	2017-09-12 17:58:49.035	info	instance system.adapter.hs100.0 started with pid 758
                    host.iobroker	2017-09-12 17:58:18.982	info	Restart adapter system.adapter.hs100.0 because enabled
                    host.iobroker	2017-09-12 17:58:18.982	error	instance system.adapter.hs100.0 terminated with code 0 (OK)
                    hs100.0	2017-09-12 17:58:18.959	info	terminating
                    hs100.0	2017-09-12 17:58:18.448	error	at Manager.Emitter.emit (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/node_modules/component-emitter/index.js:133:20)
                    hs100.0	2017-09-12 17:58:18.448	error	at Manager. (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/node_modules/component-bind/index.js:21:15)
                    hs100.0	2017-09-12 17:58:18.448	error	at Socket.onpacket (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/socket.js:236:12)
                    hs100.0	2017-09-12 17:58:18.448	error	at Socket.onack (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/socket.js:312:9)
                    hs100.0	2017-09-12 17:58:18.448	error	at Socket. (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:703:25)
                    hs100.0	2017-09-12 17:58:18.448	error	at initAdapter (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4527:18)
                    hs100.0	2017-09-12 17:58:18.448	error	at Adapter.emit (events.js:166:7)
                    hs100.0	2017-09-12 17:58:18.448	error	at emitNone (events.js:67:13)
                    hs100.0	2017-09-12 17:58:18.448	error	at Adapter. (/opt/iobroker/node_modules/iobroker.hs100/main.js:30:5)
                    hs100.0	2017-09-12 17:58:18.448	error	at main (/opt/iobroker/node_modules/iobroker.hs100/main.js:377:32)
                    hs100.0	2017-09-12 17:58:18.448	error	TypeError: Cannot read property 'length' of undefined
                    hs100.0	2017-09-12 17:58:18.438	error	uncaught exception: Cannot read property 'length' of undefined
                    
                    1 Reply Last reply Reply Quote 0
                    • arteck
                      arteck Developer Most Active last edited by

                      @Pocky:

                      Hallo @ All

                      Adapter erfolgreich installiert.

                      Kann mir jemand sagen wie ich die Verbrauchsdaten mit iobroker angezeigt bekomme?

                      Grüße Pocky 🙂 `

                      nur die HS110 sammelt nur die Daten .. da gibt es Datenobjekte für ..

                      die HS100 hat die nicht

                      1 Reply Last reply Reply Quote 0
                      • arteck
                        arteck Developer Most Active last edited by

                        @muckel:

                        Hallo Arteck

                        Kannst du mir dazu einen Tip geben.

                        Danke im Voraus

                        liebe Grüße

                        host.iobroker	2017-09-12 17:59:22.814	info	Restart adapter system.adapter.hs100.0 because enabled
                        host.iobroker	2017-09-12 17:59:22.813	error	instance system.adapter.hs100.0 terminated with code 0 (OK)
                        hs100.0	2017-09-12 17:59:22.313	error	TypeError: Cannot read property 'length' of undefined at main (/opt/iobroker/node_modules/iobroker.hs100/main.js:377:32) at Adapter. (/opt/iobroker/node_modules/iobroker.hs100/main.
                        hs100.0	2017-09-12 17:59:22.313	error	uncaught exception: Cannot read property 'length' of undefined
                        hs100.0	2017-09-12 17:59:22.311	info	starting. Version 0.0.16 in /opt/iobroker/node_modules/iobroker.hs100, node: v4.7.2
                        host.iobroker	2017-09-12 17:59:20.913	info	instance system.adapter.hs100.0 started with pid 768
                        host.iobroker	2017-09-12 17:58:50.869	info	Restart adapter system.adapter.hs100.0 because enabled
                        host.iobroker	2017-09-12 17:58:50.869	error	instance system.adapter.hs100.0 terminated with code 0 (OK)
                        hs100.0	2017-09-12 17:58:50.369	error	TypeError: Cannot read property 'length' of undefined at main (/opt/iobroker/node_modules/iobroker.hs100/main.js:377:32) at Adapter. (/opt/iobroker/node_modules/iobroker.hs100/main.
                        hs100.0	2017-09-12 17:58:50.368	error	uncaught exception: Cannot read property 'length' of undefined
                        hs100.0	2017-09-12 17:58:50.367	info	starting. Version 0.0.16 in /opt/iobroker/node_modules/iobroker.hs100, node: v4.7.2
                        host.iobroker	2017-09-12 17:58:49.035	info	instance system.adapter.hs100.0 started with pid 758
                        host.iobroker	2017-09-12 17:58:18.982	info	Restart adapter system.adapter.hs100.0 because enabled
                        host.iobroker	2017-09-12 17:58:18.982	error	instance system.adapter.hs100.0 terminated with code 0 (OK)
                        hs100.0	2017-09-12 17:58:18.959	info	terminating
                        hs100.0	2017-09-12 17:58:18.448	error	at Manager.Emitter.emit (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/node_modules/component-emitter/index.js:133:20)
                        hs100.0	2017-09-12 17:58:18.448	error	at Manager. (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/node_modules/component-bind/index.js:21:15)
                        hs100.0	2017-09-12 17:58:18.448	error	at Socket.onpacket (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/socket.js:236:12)
                        hs100.0	2017-09-12 17:58:18.448	error	at Socket.onack (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/socket.js:312:9)
                        hs100.0	2017-09-12 17:58:18.448	error	at Socket. (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:703:25)
                        hs100.0	2017-09-12 17:58:18.448	error	at initAdapter (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4527:18)
                        hs100.0	2017-09-12 17:58:18.448	error	at Adapter.emit (events.js:166:7)
                        hs100.0	2017-09-12 17:58:18.448	error	at emitNone (events.js:67:13)
                        hs100.0	2017-09-12 17:58:18.448	error	at Adapter. (/opt/iobroker/node_modules/iobroker.hs100/main.js:30:5)
                        hs100.0	2017-09-12 17:58:18.448	error	at main (/opt/iobroker/node_modules/iobroker.hs100/main.js:377:32)
                        hs100.0	2017-09-12 17:58:18.448	error	TypeError: Cannot read property 'length' of undefined
                        hs100.0	2017-09-12 17:58:18.438	error	uncaught exception: Cannot read property 'length' of undefined
                        ```` `  
                        

                        hast du IP's eingetragen ?? von den Dosen

                        1 Reply Last reply Reply Quote 0
                        • M
                          muckel last edited by

                          @arteck:

                          @muckel:

                          Hallo Arteck

                          Kannst du mir dazu einen Tip geben.

                          Danke im Voraus

                          liebe Grüße

                          host.iobroker	2017-09-12 17:59:22.814	info	Restart adapter system.adapter.hs100.0 because enabled
                          host.iobroker	2017-09-12 17:59:22.813	error	instance system.adapter.hs100.0 terminated with code 0 (OK)
                          hs100.0	2017-09-12 17:59:22.313	error	TypeError: Cannot read property 'length' of undefined at main (/opt/iobroker/node_modules/iobroker.hs100/main.js:377:32) at Adapter. (/opt/iobroker/node_modules/iobroker.hs100/main.
                          hs100.0	2017-09-12 17:59:22.313	error	uncaught exception: Cannot read property 'length' of undefined
                          hs100.0	2017-09-12 17:59:22.311	info	starting. Version 0.0.16 in /opt/iobroker/node_modules/iobroker.hs100, node: v4.7.2
                          host.iobroker	2017-09-12 17:59:20.913	info	instance system.adapter.hs100.0 started with pid 768
                          host.iobroker	2017-09-12 17:58:50.869	info	Restart adapter system.adapter.hs100.0 because enabled
                          host.iobroker	2017-09-12 17:58:50.869	error	instance system.adapter.hs100.0 terminated with code 0 (OK)
                          hs100.0	2017-09-12 17:58:50.369	error	TypeError: Cannot read property 'length' of undefined at main (/opt/iobroker/node_modules/iobroker.hs100/main.js:377:32) at Adapter. (/opt/iobroker/node_modules/iobroker.hs100/main.
                          hs100.0	2017-09-12 17:58:50.368	error	uncaught exception: Cannot read property 'length' of undefined
                          hs100.0	2017-09-12 17:58:50.367	info	starting. Version 0.0.16 in /opt/iobroker/node_modules/iobroker.hs100, node: v4.7.2
                          host.iobroker	2017-09-12 17:58:49.035	info	instance system.adapter.hs100.0 started with pid 758
                          host.iobroker	2017-09-12 17:58:18.982	info	Restart adapter system.adapter.hs100.0 because enabled
                          host.iobroker	2017-09-12 17:58:18.982	error	instance system.adapter.hs100.0 terminated with code 0 (OK)
                          hs100.0	2017-09-12 17:58:18.959	info	terminating
                          hs100.0	2017-09-12 17:58:18.448	error	at Manager.Emitter.emit (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/node_modules/component-emitter/index.js:133:20)
                          hs100.0	2017-09-12 17:58:18.448	error	at Manager. (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/node_modules/component-bind/index.js:21:15)
                          hs100.0	2017-09-12 17:58:18.448	error	at Socket.onpacket (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/socket.js:236:12)
                          hs100.0	2017-09-12 17:58:18.448	error	at Socket.onack (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/socket.js:312:9)
                          hs100.0	2017-09-12 17:58:18.448	error	at Socket. (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:703:25)
                          hs100.0	2017-09-12 17:58:18.448	error	at initAdapter (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4527:18)
                          hs100.0	2017-09-12 17:58:18.448	error	at Adapter.emit (events.js:166:7)
                          hs100.0	2017-09-12 17:58:18.448	error	at emitNone (events.js:67:13)
                          hs100.0	2017-09-12 17:58:18.448	error	at Adapter. (/opt/iobroker/node_modules/iobroker.hs100/main.js:30:5)
                          hs100.0	2017-09-12 17:58:18.448	error	at main (/opt/iobroker/node_modules/iobroker.hs100/main.js:377:32)
                          hs100.0	2017-09-12 17:58:18.448	error	TypeError: Cannot read property 'length' of undefined
                          hs100.0	2017-09-12 17:58:18.438	error	uncaught exception: Cannot read property 'length' of undefined
                          ```` `  
                          

                          hast du IP's eingetragen ?? von den Dosen `

                          Gesendet von iPhone mit Tapatalk

                          1 Reply Last reply Reply Quote 0
                          • M
                            muckel last edited by

                            @muckel:

                            @arteck:

                            @muckel:

                            Hallo Arteck

                            Kannst du mir dazu einen Tip geben.

                            Danke im Voraus

                            liebe Grüße

                            host.iobroker	2017-09-12 17:59:22.814	info	Restart adapter system.adapter.hs100.0 because enabled
                            host.iobroker	2017-09-12 17:59:22.813	error	instance system.adapter.hs100.0 terminated with code 0 (OK)
                            hs100.0	2017-09-12 17:59:22.313	error	TypeError: Cannot read property 'length' of undefined at main (/opt/iobroker/node_modules/iobroker.hs100/main.js:377:32) at Adapter. (/opt/iobroker/node_modules/iobroker.hs100/main.
                            hs100.0	2017-09-12 17:59:22.313	error	uncaught exception: Cannot read property 'length' of undefined
                            hs100.0	2017-09-12 17:59:22.311	info	starting. Version 0.0.16 in /opt/iobroker/node_modules/iobroker.hs100, node: v4.7.2
                            host.iobroker	2017-09-12 17:59:20.913	info	instance system.adapter.hs100.0 started with pid 768
                            host.iobroker	2017-09-12 17:58:50.869	info	Restart adapter system.adapter.hs100.0 because enabled
                            host.iobroker	2017-09-12 17:58:50.869	error	instance system.adapter.hs100.0 terminated with code 0 (OK)
                            hs100.0	2017-09-12 17:58:50.369	error	TypeError: Cannot read property 'length' of undefined at main (/opt/iobroker/node_modules/iobroker.hs100/main.js:377:32) at Adapter. (/opt/iobroker/node_modules/iobroker.hs100/main.
                            hs100.0	2017-09-12 17:58:50.368	error	uncaught exception: Cannot read property 'length' of undefined
                            hs100.0	2017-09-12 17:58:50.367	info	starting. Version 0.0.16 in /opt/iobroker/node_modules/iobroker.hs100, node: v4.7.2
                            host.iobroker	2017-09-12 17:58:49.035	info	instance system.adapter.hs100.0 started with pid 758
                            host.iobroker	2017-09-12 17:58:18.982	info	Restart adapter system.adapter.hs100.0 because enabled
                            host.iobroker	2017-09-12 17:58:18.982	error	instance system.adapter.hs100.0 terminated with code 0 (OK)
                            hs100.0	2017-09-12 17:58:18.959	info	terminating
                            hs100.0	2017-09-12 17:58:18.448	error	at Manager.Emitter.emit (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/node_modules/component-emitter/index.js:133:20)
                            hs100.0	2017-09-12 17:58:18.448	error	at Manager. (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/node_modules/component-bind/index.js:21:15)
                            hs100.0	2017-09-12 17:58:18.448	error	at Socket.onpacket (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/socket.js:236:12)
                            hs100.0	2017-09-12 17:58:18.448	error	at Socket.onack (/opt/iobroker/node_modules/iobroker.js-controller/node_modules/socket.io-client/lib/socket.js:312:9)
                            hs100.0	2017-09-12 17:58:18.448	error	at Socket. (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:703:25)
                            hs100.0	2017-09-12 17:58:18.448	error	at initAdapter (/opt/iobroker/node_modules/iobroker.js-controller/lib/adapter.js:4527:18)
                            hs100.0	2017-09-12 17:58:18.448	error	at Adapter.emit (events.js:166:7)
                            hs100.0	2017-09-12 17:58:18.448	error	at emitNone (events.js:67:13)
                            hs100.0	2017-09-12 17:58:18.448	error	at Adapter. (/opt/iobroker/node_modules/iobroker.hs100/main.js:30:5)
                            hs100.0	2017-09-12 17:58:18.448	error	at main (/opt/iobroker/node_modules/iobroker.hs100/main.js:377:32)
                            hs100.0	2017-09-12 17:58:18.448	error	TypeError: Cannot read property 'length' of undefined
                            hs100.0	2017-09-12 17:58:18.438	error	uncaught exception: Cannot read property 'length' of undefined
                            ```` `  
                            

                            hast du IP's eingetragen ?? von den Dosen `

                            Gesendet von iPhone mit Tapatalk `

                            Ja natürlich.

                            Es funktioniert ja alles.

                            Gesendet von iPhone mit Tapatalk

                            1 Reply Last reply Reply Quote 0
                            • AlCalzone
                              AlCalzone Developer last edited by

                              hs100.0   2017-09-12 17:58:18.448   error   at main (/opt/iobroker/node_modules/iobroker.hs100/main.js:377:32)
                              hs100.0   2017-09-12 17:58:18.448   error   TypeError: Cannot read property 'length' of undefined
                              

                              bedeutet

                              {ZEILE 377}: if (!adapter.config.devices.length) {
                              

                              adapter.config.devices ist undefined.

                              Da fehlt wohl die Eigenschaft im Adapter-Objekt (müsste per Expertenmodus unter hs100.0 zu finden sein, Abschnitt "native").

                              Wurde die eventuell mit einem Update hinzugefügt?

                              1 Reply Last reply Reply Quote 0
                              • AlCalzone
                                AlCalzone Developer last edited by

                                @UweRLP:

                                laut Changelog soll es eine 0.0.16 (2017-08-19) geben, installiert wird aber eine 0.0.15 (Anzeige in Admin). `
                                Da hat arteck wohl vergessen die io-package.json anzupassen.

                                Adapter-testing fängt dieses Problem übrigens ab, könnte man mal aktivieren 😉

                                1 Reply Last reply Reply Quote 0
                                • M
                                  muckel last edited by

                                  @AlCalzone:

                                  @UweRLP:

                                  laut Changelog soll es eine 0.0.16 (2017-08-19) geben, installiert wird aber eine 0.0.15 (Anzeige in Admin). `
                                  Da hat arteck wohl vergessen die io-package.json anzupassen.

                                  Adapter-testing fängt dieses Problem übrigens ab, könnte man mal aktivieren 😉 `

                                  Gesendet von iPhone mit Tapatalk

                                  1 Reply Last reply Reply Quote 0
                                  • M
                                    muckel last edited by

                                    @muckel:

                                    @AlCalzone:

                                    @UweRLP:

                                    laut Changelog soll es eine 0.0.16 (2017-08-19) geben, installiert wird aber eine 0.0.15 (Anzeige in Admin). `
                                    Da hat arteck wohl vergessen die io-package.json anzupassen.

                                    Adapter-testing fängt dieses Problem übrigens ab, könnte man mal aktivieren 😉 `

                                    Das könnte ich mal probieren.

                                    Danke für den tip.

                                    Liebe Grüße

                                    Gesendet von iPhone mit Tapatalk `

                                    Gesendet von iPhone mit Tapatalk

                                    1 Reply Last reply Reply Quote 0
                                    • AlCalzone
                                      AlCalzone Developer last edited by

                                      @muckel:

                                      Das könnte ich mal probieren.

                                      Danke für den tip. `
                                      Das war an Arteck als Entwickler gerichtet. Dann sieht man wie https://github.com/AlCalzone/ioBroker.tradfri/blob/master/README.md auf den ersten Blick ob irgendwas grundlegendes nicht stimmt.

                                      1 Reply Last reply Reply Quote 0
                                      • arteck
                                        arteck Developer Most Active last edited by

                                        ihr müsst mir verzeihen.. ich bau gerade mein Haus um.. soweit ich Zeit finde.. wirds korrigiert

                                        1 Reply Last reply Reply Quote 0
                                        • D
                                          DavidT last edited by

                                          Hallo,

                                          ich habe den ganzen Abend verzweifelt versucht den Adapter zu installieren (wie von Dir beschrieben), leider ohne Erfolg.

                                          Bei dem Versuch mein node zu updaten habe ich mir meinen Container total zerschossen, hatte kein Backup usw. Ohne viele Linux und Docker-Kenntnisse echt eine Herausforderung 🙂

                                          Ich habe wie von dir beschrieben das ganze in der Shell installiert (0.0.17) mit aktuellen node und bekomme bei "iobroker add hs100" folgenden Fehler:

                                          root@T-NAS:/opt/iobroker# iobroker add hs100
                                          host.T-NAS install adapter hs100
                                          host.T-NAS error: reading io-package.json SyntaxError: Unexpected token , in JSON at position 1152
                                          
                                          

                                          Mache ich irgendwas falsch!? Bin mit meinem Latein am ende 🙂

                                          Gruß David

                                          1 Reply Last reply Reply Quote 0
                                          • D
                                            DavidT last edited by

                                            Ok, wenn man die einfachen Probleme nicht sieht… In der io-package.json ist ein Syntaxfehler. Habe es gefixt und einen Pullrequest erstellt.

                                            Danke für Deine Arbeit!

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            810
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            41
                                            215
                                            43169
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo