    Aufruf Sammlung an Modbus Anbindungen

    This topic has been deleted. Only users with topic management privileges can see it.
    • TheBam
      TheBam @Schello805 last edited by

      @schello805
      Danke sieht gut aus. Kannst du evtl. Einen Export der Eingangsregister Posten?

      1 Reply Last reply Reply Quote 0
      • V
        V8Turbo @TheBam last edited by

        Gibt es etwas für Sofar Solar HYD 10 KTL WR ? Ich finde nur HEX Werte, wie kann man die eingeben ??

        wendy2702 1 Reply Last reply Reply Quote 0
        • wendy2702
          wendy2702 @V8Turbo last edited by

          @v8turbo HEX to Dec umrechnen mal versucht ?

          1 Reply Last reply Reply Quote 0
          • wendy2702
            wendy2702 last edited by

            Waterkotte EcoTouch Ai1 Geo 5008.5

            Auslesen:

            _address	name	description	unit	type	len	factor	offset	formula	role	room	cw	isScale
            1	Außentemperatur		°C	int16be	1	0.1	0		value		false	false
            2	Außentemperatur 1h Durchschnitt		°C	int16be	1	0.1	0		value		false	false
            3	Außentemperatur 24h Durchschnitt		°C	int16be	1	0.1	0		value		false	false
            4	Quelle ein		°C	int16be	1	0.1	0		value		false	false
            5	Quelle aus		°C	int16be	1	0.1	0		value		false	false
            6	Temperatur Verdampfer		°C	int16be	1	0.1	0		value		false	false
            7	Sauggastemperatur		°C	int16be	1	0.1	0		value		false	false
            8	Verdampfungsdruck		bar	int16be	1	0.1	0		value		false	false
            9	Druckgastemperatur	???	°C	int16be	1	0.1	0		value		false	false
            10	Rücklauf Soll		°C	int16be	1	0.1	0		value		false	false
            11	Rücklauf HZ		°C	int16be	1	0.1	0		value		false	false
            12	Vorlauf HZ		°C	int16be	1	0.1	0		value		false	false
            13	Temperatur Verflüssiger		°C	int16be	1	0.1	0		value		false	false
            15	Kondensationsdruck	???	bar	int16be	1	0.1	0		value		false	false
            17	Raumtemperatur_Abluft_KWL		°C	int16be	1	0.1	0		value		false	false
            18	Raumtemperatur_1_Stunde_Durchschnitt		°C	int16be	1	0.1	0		value		false	false
            19	Wasserspeicher Temperatur		°C	int16be	1	0.1	0		value		false	false
            23	Expansionsventil		%	int16be	1	0.1	0		value		false	false
            25	Verdichter Leistungsaufnahme		kW	int16be	1	0.1	0		value		false	false
            26	Thermische Energie		kw	int16be	1	0.1	0		value		false	false
            28	COP Waerme			int16be	1	0.1	0		value		false	false
            29	COP Kälte			int16be	1	0.1	0		value		false	false
            30	Heizung Ist		°C	int16be	1	0.1	0		value		false	false
            31	Heizung Soll		°C	int16be	1	0.1	0		value		false	false
            33	Kühlung Ist		°C	int16be	1	0.1	0		value		false	false
            34	Kühlung Soll		°C	int16be	1	0.1	0		value		false	false
            37	Warmwasser Soll		°C	int16be	1	0.1	0		value		false	false
            51	Heizkreispumpe Leistung		%	int16be	1	0.1	0		value		false	false
            52	Quellenpumpe_Leistung		%	int16be	1	0.1	0		value		false	false
            58	Leistung Kompressor %		%	int16be	1	0.1	0		value		false	false
            418	Energie_Verdichter_aktueller_Monat			int16be	1	0.1	0		value		false	false
            420	Energie_Quellenpumpe_aktueller_Monat			int16be	1	0.1	0		value		false	false
            435	Arbeitszahl_Gesamtsystem			int16be	1	0.1	0		value		false	false
            461	Arbeitszahl_Aktuelles_Jahr			int16be	1	0.1	0		value		false	false
            682	Sollwerterhöhung Heizkreis PV			int16be	1	0.1	0		value		false	false
            683	Sollwerterhöhung Kühlung PV			int16be	1	0.1	0		value		false	false
            684	Sollwerterhöhung Warmwasser PV			int16be	1	0.1	0		value		false	false
            818	Elektrische_Energie_Gesamt_Januar		kWh	int16be	1	0.1	0		value		false	false
            819	Elektrische_Energie_Gesamt_Februar		kWh	int16be	1	0.1	0		value		false	false
            820	Elektrische_Energie_Gesamt_März		kWh	int16be	1	0.1	0		value		false	false
            821	Elektrische_Energie_Gesamt_April		kWh	int16be	1	0.1	0		value		false	false
            822	Elektrische_Energie_Gesamt_Mai		kWh	int16be	1	0.1	0		value		false	false
            823	Elektrische_Energie_Gesamt_Juni		kWh	int16be	1	0.1	0		value		false	false
            824	Elektrische_Energie_Gesamt_Juli		kWh	int16be	1	0.1	0		value		false	false
            825	Elektrische_Energie_Gesamt_August		kWh	int16be	1	0.1	0		value		false	false
            826	Elektrische_Energie_Gesamt_September		kWh	int16be	1	0.1	0		value		false	false
            827	Elektrische Leistung Gesamt Oktober		kWh	int16be	1	0.1	0		value		false	false
            827	Elektrische_Energie_Gesamt_Oktober		kWh	int16be	1	0.1	0		value		false	false
            828	Elektrische_Energie_Gesamt_November		kWh	int16be	1	0.1	0		value		false	false
            829	Elektrische_Energie_Gesamt_Dezember		kWh	int16be	1	0.1	0		value		false	false
            830	Thermische_Leistung_Heizung_Januar		kWh	int16be	1	0.1	0		value		false	false
            831	Thermische_Leistung_Heizung_Februar		kWh	int16be	1	0.1	0		value		false	false
            832	Thermische_Leistung_Heizung_März		kWh	int16be	1	0.1	0		value		false	false
            833	Thermische_Leistung_Heizung_April		kWh	int16be	1	0.1	0		value		false	false
            834	Thermische_Leistung_Heizung_Mai		kWh	int16be	1	0.1	0		value		false	false
            835	Thermische_Leistung_Heizung_Juni		kWh	int16be	1	0.1	0		value		false	false
            836	Thermische_Leistung_Heizung_Juli		kWh	int16be	1	0.1	0		value		false	false
            837	Thermische_Leistung_Heizung_August		kWh	int16be	1	0.1	0		value		false	false
            838	Thermische_Leistung_Heizung_September		kWh	int16be	1	0.1	0		value		false	false
            839	Thermische_Leistung_Heizung_Oktober		kWh	int16be	1	0.1	0		value		false	false
            840	Thermische_Leistung_Heizung_November		kWh	int16be	1	0.1	0		value		false	false
            841	Thermische_Leistung_Heizung_Dezember		kWh	int16be	1	0.1	0		value		false	false
            842	Thermische_Leistung_Warmwasser_Januar		kWh	int16be	1	0.1	0		value		false	false
            843	Thermische_Leistung_Warmwasser_Februar		kWh	int16be	1	0.1	0		value		false	false
            844	Thermische_Leistung_Warmwasser_März		kWh	int16be	1	0.1	0		value		false	false
            845	Thermische_Leistung_Warmwasser_April		kWh	int16be	1	0.1	0		value		false	false
            846	Thermische_Leistung_Warmwasser_Mai		kWh	int16be	1	0.1	0		value		false	false
            847	Thermische_Leistung_Warmwasser_Juni		kWh	int16be	1	0.1	0		value		false	false
            848	Thermische_Leistung_Warmwasser_Juli		kWh	int16be	1	0.1	0		value		false	false
            849	Thermische_Leistung_Warmwasser_August		kWh	int16be	1	0.1	0		value		false	false
            850	Thermische_Leistung_Warmwasser_September		kWh	int16be	1	0.1	0		value		false	false
            851	Thermische_Leistung_Warmwasser_Oktober		kWh	int16be	1	0.1	0		value		false	false
            852	Thermische_Leistung_Warmwasser_November		kWh	int16be	1	0.1	0		value		false	false
            853	Thermische_Leistung_Warmwasser_Dezember		kWh	int16be	1	0.1	0		value		false	false
            878	Thermische_Leistung_Gesamt_Januar		kWh	int16be	1	0.1	0		value		false	false
            879	Thermische_Leistung_Gesamt_Februar		kWh	int16be	1	0.1	0		value		false	false
            880	Thermische_Leistung_Gesamt_März		kWh	int16be	1	0.1	0		value		false	false
            881	Thermische_Leistung_Gesamt_April		kWh	int16be	1	0.1	0		value		false	false
            882	Thermische_Leistung_Gesamt_Mai		kWh	int16be	1	0.1	0		value		false	false
            883	Thermische_Leistung_Gesamt_Juni		kWh	int16be	1	0.1	0		value		false	false
            884	Thermische_Leistung_Gesamt_Juli		kWh	int16be	1	0.1	0		value		false	false
            885	Thermische_Leistung_Gesamt_August		kWh	int16be	1	0.1	0		value		false	false
            886	Thermische_Leistung_Gesamt_September		kWh	int16be	1	0.1	0		value		false	false
            887	Thermische_Leistung_Gesamt_Oktober		kWh	int16be	1	0.1	0		value		false	false
            888	Thermische_Leistung_Gesamt_November		kWh	int16be	1	0.1	0		value		false	false
            889	Thermische_Leistung_Gesamt_Dezember		kWh	int16be	1	0.1	0		value		false	false
            924	COP_Gesamt_Januar			int16be	1	0.1	0		value		false	false
            925	COP_Gesamt_Februar			int16be	1	0.1	0		value		false	false
            926	COP_Gesamt_März			int16be	1	0.1	0		value		false	false
            927	COP_Gesamt_April			int16be	1	0.1	0		value		false	false
            928	COP_Gesamt_Mai			int16be	1	0.1	0		value		false	false
            929	COP_Gesamt_Juni			int16be	1	0.1	0		value		false	false
            930	COP_Gesamt_Juli			int16be	1	0.1	0		value		false	false
            931	COP_Gesamt_August			int16be	1	0.1	0		value		false	false
            932	COP_Gesamt_September			int16be	1	0.1	0		value		false	false
            933	COP_Gesamt_Oktober			int16be	1	0.1	0		value		false	false
            934	COP_Gesamt_November			int16be	1	0.1	0		value		false	false
            935	COP_Gesamt_Dezember			int16be	1	0.1	0		value		false	false
            5006	Aktueller_Tag			int16be	1	1	0		value		false	false
            5007	Aktueller_Monat			int16be	1	1	0		value		false	false
            5008	Aktuelles_Jahr			int16be	1	1	0		value		false	false
            5009	Aktuelle_Stunde			int16be	1	1	0		value		false	false
            5010	Aktuelle_Minute			int16be	1	1	0		value		false	false
            5011	Betriebsstunden_Verdichter		h	int16be	1	1	0		value		false	false
            5019	Betriebsstunden_Heizungsumwälzpumpe		h	int16be	1	1	0		value		false	false
            5021	Betriebsstunden_Quellenpumpe		h	int16be	1	1	0		value		false	false
            5052	Zustand_WP			int16be	1	1	0		value		false	false
            

            ändern WW Temp:

            _address	name	description	unit	type	len	factor	offset	formula	role	room	poll	wp	cw	isScale
            38	Wassertemperatur Soll		°C	uint16be	1	1	0		level		true			
            

            Wenn man z.B. Eine WW-Temp von 55 Grad einstellen muss man das Register mit "550" beschreiben. Zumindest ist das bei mir so.

            F E P 3 Replies Last reply Reply Quote 1
            • M
              MartyBr last edited by

              Kostal Smart Energy Meter:

              _address	name	description	unit	type	len	factor	offset	formula	role	room	poll	wp	cw	isScale
              0	Summe_Leistung_Netzbezug	Wirkleistung (Netzbezug)	W	uint32be	2	1	0		value		true			
              2	Summe_Leistung_Einspeisung	Wirkleistung (Einspeisung)	W	uint32be	2	1	0		value		true			
              4	Summe_Blindleistung_Netzbezug	Blindleistung (Netzbezug)	W	uint32be	2	1	0		value		true			
              6	Summe_Blindleistung_Einspeisung	Blindleistung (Einspeisung)	W	uint32be	2	1	0		value		true			
              16	Summe_Scheinleistung_Netzbezug	Scheinleistung (Netzbezug)	W	uint32be	2	1	0		value		true			
              18	Summe_Scheinleistung_Einspeisung	Scheinleistung (Einspeisung)	W	uint32be	2	1	0		value		true			
              40004	Hersteller	Hersteller		string	2	1	0		value		true			
              40020	Name	Name		string	2	1	0		value		true			
              40052	Seriennummer	Seriennummer		string	2	1	0		value		true			
              40071	M_AC_Current	AC Current (sum of active phases)	A	int16be	1	1	0		value		true			
              40072	M_AC_Current_A	Phase A AC current	A	int16be	1	1	0		value		true			
              40073	M_AC_Current_B	Phase B AC current	A	int16be	1	1	0		value		true			
              40074	M_AC_Current_C	Phase C AC current	A	int16be	1	1	0		value		true			
              40075	M_AC_Current_SF	AC Current Scale Factor		int16be	1	1	0		value		true			
              40076	M_AC_Voltage_LN	Line to Neutral AC Voltage (average of active phases)	V	int16be	1	1	0		value		true			
              40077	M_AC_Voltage_LA	Phase A to Neutral AC Voltage	V	int16be	1	1	0		value		true			
              40078	M_AC_Voltage_LB	Phase B to Neutral AC Voltage	V	int16be	1	1	0		value		true			
              40079	M_AC_Voltage_CN	Phase C to Neutral AC Voltage	V	int16be	1	1	0		value		true			
              40080	M_AC_Voltage_LL	Line to Line AC Voltage (average of active phases)	V	int16be	1	1	0		value		true			
              40081	M_AC_Voltage_AB	Phase A to Phase B AC Voltage	V	int16be	1	1	0		value		true			
              40082	M_AC_Voltage_BC	Phase B to Phase C AC Voltage	V	int16be	1	1	0		value		true			
              40083	M_AC_Voltage_CA	Phase C to Phase A AC Voltage	V	int16be	1	1	0		value		true			
              40084	M_AC_Voltage_SF	AC Voltage Scale Factor		int16be	1	1	0		value		true			
              40085	M_AC_Freq	AC Frequency	Hz	int16be	1	1	0		value		true			
              40086	M_AC_Freq_SF	AC Frequency Scale Factor		int16be	1	1	0		value		true			
              40087	M_AC_Power	Total Real Power (sum of active phases)	W	int16be	1	1	0		value		true			
              40088	M_AC_Power_A	Phase A AC Real Power	W	int16be	1	1	0		value		true			
              40089	M_AC_Power_B	Phase B AC Real Power	W	int16be	1	1	0		value		true			
              40090	M_AC_Power_C	Phase C AC Real Power	W	int16be	1	1	0		value		true			
              40091	M_AC_Power_SF	AC Real Power Scale Factor		int16be	1	1	0		value		true			
              40092	M_AC_VA	Total AC Apparent Power (sum of active phases)	VA	int16be	1	1	0		value		true			
              40093	M_AC_VA_A	Phase A AC Apparent Power	VA	int16be	1	1	0		value		true			
              40094	M_AC_VA_B	Phase B AC Apparent Power	VA	int16be	1	1	0		value		true			
              40095	M_AC_VA_C	Phase C AC Apparent Power	VA	int16be	1	1	0		value		true			
              40096	M_AC_VA_SF	AC Apparent Power Scale Factor		int16be	1	1	0		value		true			
              40097	M_AC_VAR	Total AC Reactive Power (sum of ac- tive phases)	var	int16be	1	1	0		value		true			
              40098	M_AC_VAR_A	Phase A AC Reactive Power	var	int16be	1	1	0		value		true			
              40099	M_AC_VAR_B	Phase B AC Reactive Power	var	int16be	1	1	0		value		true			
              40100	M_AC_VAR_C	Phase C AC Reactive Power	var	int16be	1	1	0		value		true			
              40101	M_AC_VAR_ SF	AC Reactive Power Scale Factor		int16be	1	1	0		value		true			
              40102	M_AC_PF	Average Power Factor (average of active phases)	%	int16be	1	1	0		value		true			
              40103	M_AC_PF_A	Phase A Power Factor	%	int16be	1	1	0		value		true			
              40104	M_AC_PF_B	Phase B Power Factor	%	int16be	1	1	0		value		true			
              40105	M_AC_PF_C	Phase C Power Factor	%	int16be	1	1	0		value		true			
              40106	M_AC_PF_SF	AC Power Factor Scale Factor		int16be	1	1	0		value		true			
              40107	M_Exported	Total Exported Real Energy	Wh	int32be	2	1	0		value		true			
              40109	M_Exported_A	Phase A Exported Real Energy	Wh	int32be	2	1	0		value		true			
              40111	M_Exported_B	Phase B Exported Real Energy	Wh	int32be	2	1	0		value		true			
              40113	M_Exported_C	Phase C Exported Real Energy	Wh	int32be	2	1	0		value		true			
              40115	M_Imported	Total Imported Real Energy	Wh	int32be	2	1	0		value		true			
              40117	M_Imported_A	Phase A Imported Real Energy	Wh	int32be	2	1	0		value		true			
              40119	M_Imported_B	Phase B Imported Real Energy	Wh	int32be	2	1	0		value		true			
              40121	M_Imported_C	Phase C Imported Real Energy	Wh	uint32sw	2	1	0		value		true			
              40123	M_Energy_W_SF	Real Energy Scale Factor3		int16be	1	1	0		value		true			
              40124	M_Exported_VA	Total Exported Apparent Energy	VAh	int32be	2	1	0		value		true			
              40126	M_Exported_VA_A	Phase A Exported Apparent Energy	VAh	int32be	2	1	0		value		true			
              40128	M_Exported_VA_B	Phase B Exported Apparent Energy	VAh	int32be	2	1	0		value		true			
              40130	M_Exported_VA_C	Phase C Exported Apparent Energy	VAh	int32be	2	1	0		value		true			
              40132	M_Imported_VA	Total Imported Apparent Energy	VAh	int32be	2	1	0		value		true			
              40134	M_Imported_VA_A	Phase A Imported Apparent Energy	VAh	int32be	2	1	0		value		true			
              40136	M_Imported_VA_B	Phase B Imported Apparent Energy	VAh	int32be	2	1	0		value		true			
              40138	M_Imported_VA_C	Phase C Imported Apparent Energy	VAh	int32be	2	1	0		value		true			
              40140	M_Energy_VA_SF	Apparent Energy Scale Factor		int16be	1	1	0		value		true			
              40141	M_Import_VARh_Q1	Quadrant 1: Tota Imported Reactive Energy	VARh	int32be	2	1	0		value		true			
              40143	M_Import_VARh_Q1A	Phase A – Quadrant 1: Imported Reac- tive Energy	VARh	int32be	2	1	0		value		true			
              40145	M_Import_VARh_Q1B	Phase B – Quadrant 1: Imported Reac- tive Energy	VARh	int32be	2	1	0		value		true			
              40147	M_Import_VARh_Q1C	Phase C – Quadrant 1: Imported Reac- tive Energy	VARh	int32be	2	1	0		value		true			
              40149	M_Import_VARh_Q2	Quadrant 2: Total Imported Reactive Energy	VARh	int32be	2	1	0		value		true			
              40151	M_Import_VARh_Q2A	Phase A – Quadrant 2: Imported Reac- tive Energy	VARh	int32be	2	1	0		value		true			
              40153	M_Import_VARh_Q2B	Phase B – Quadrant 2: Imported Reac- tive Energy	VARh	int32be	2	1	0		value		true			
              40155	M_Import_VARh_Q2C	Phase C – Quadrant 2: Imported Reac- tive Energy	VARh	int32be	2	1	0		value		true			
              40157	M_Export_VARh_Q3	Quadrant 3: Total Imported Reactive Energy	VARh	int32be	2	1	0		value		true			
              40159	M_Export_VARh_Q3A	Phase A – Quadrant 3: Imported Reac- tive Energy	VARh	int32be	2	1	0		value		true			
              40161	M_Export_VARh_Q3B	Phase B – Quadrant 3: Imported Reac- tive Energy	VARh	int32be	2	1	0		value		true			
              40163	M_Export_VARh_Q3C	Phase C – Quadrant 3: Imported Reac- tive Energy	VARh	int32be	2	1	0		value		true			
              40165	M_Export_VARh_Q4	Quadrant 4: Tota Imported Reactive Energy	VARh	int32be	2	1	0		value		true			
              40167	M_Export_VARh_Q4A	Phase A – Quadrant 4: Imported Reac- tive Energy	VARh	int32be	2	1	0		value		true			
              40169	M_Export_VARh_Q4B	Phase B – Quadrant 4: Imported Reac- tive Energy	VARh	int32be	2	1	0		value		true			
              40171	M_Export_VARh_Q4C	Phase C – Quadrant 4: Imported Reac- tive Energy	VARh	int32be	2	1	0		value		true			
              40173	M_Energy_VAR_SF	Reactive Energy Scale Factor		int16be	1	1	0		value		true			
              40174	M_Events	Event flags		int32be	2	1	0		value		true			
              
              1 Reply Last reply Reply Quote 0
              • F
                Flauschi @wendy2702 last edited by

                @wendy2702 was noch cool wäre, wenn man im Holdingregister die "Temperaturanpassung" setzen könnte...
                glaub da such ich als nächstes mal:

                83394672-51c2-4910-9e4a-fbd82fdb76c3-image.png

                wendy2702 1 Reply Last reply Reply Quote 0
                • wendy2702
                  wendy2702 @Flauschi last edited by

                  @flauschi Du weisst nicht zufällig ob man die Raumtemperatur schreiben kann ?

                  apollon77 1 Reply Last reply Reply Quote 0
                  • apollon77
                    apollon77 @wendy2702 last edited by

                    @wendy2702 bitte funktionale Diskussionen in eigenen threads führen ;-). Danke

                    wendy2702 1 Reply Last reply Reply Quote 0
                    • wendy2702
                      wendy2702 @apollon77 last edited by

                      @apollon77 zur Kenntnis genommen.

                      1 Reply Last reply Reply Quote 0
                      • E
                        Eaterhnk @wendy2702 last edited by

                        @wendy2702 nutzt du die zusätzliche Modbuskarte von Waterkotte? Ich habe gelesen, dass das Auslesen von Daten wohl auch ohne diese Karte funktionieren soll. Krieg die Verbindung aber nicht hin. Mein Adapter bleibt auf rot, liegt aber auch vielleicht an den Einstellungen. Kannst du deine vielleicht noch hier reinsetzen?

                        wendy2702 1 Reply Last reply Reply Quote 0
                        • wendy2702
                          wendy2702 @Eaterhnk last edited by

                          @eaterhnk sagte in Aufruf Sammlung an Modbus Anbindungen:

                          nutzt du die zusätzliche Modbuskarte von Waterkotte? Ich habe gelesen, dass das Auslesen von Daten wohl auch ohne diese Karte funktionieren soll. Krieg die Verbindung aber nicht hin

                          OK. Wurde mir seitens Waterkotte anders erzählt aber möglich ist ja alles.

                          205c36ec-bb47-420b-9f49-850a244d7aa1-grafik.png
                          2ce6877e-1dc5-4934-b6c2-d48c2c5a24ee-grafik.png

                          E 1 Reply Last reply Reply Quote 0
                          • E
                            Eaterhnk @wendy2702 last edited by

                            @wendy2702 Danke dir, scheint aber eine Fehlinformation gewesen zu sein. Hatte es FHEM oder Loxone Forum gelesen bleibt aber weiterhin rot.

                            wendy2702 1 Reply Last reply Reply Quote 0
                            • wendy2702
                              wendy2702 @Eaterhnk last edited by

                              @eaterhnk sagte in Aufruf Sammlung an Modbus Anbindungen:

                              @wendy2702 Danke dir, scheint aber eine Fehlinformation gewesen zu sein. Hatte es FHEM oder Loxone Forum gelesen bleibt aber weiterhin rot.

                              OK. Siehe Chat da es hier nicht hin gehört

                              1 Reply Last reply Reply Quote 0
                              • M
                                mane444 last edited by

                                Hi hab einen ACTHOR9s verbaut. Ich lese die Daten aus und gebe die Bezugsleistung vom Iobroker vor.

                                Das ganze hab ich mit zwei Modbus Instanzen gelöst.
                                Hier die Einstellungen:
                                zur Übersicht:
                                IP IOB 192.168.2.220
                                ACTHOR 192.168.2.192

                                1. Modbus Instanz Daten auslesen:
                                  Einstellungen:
                                  6ac4347b-b8ff-4236-a9b7-826ce475b0e0-image.png
                                  9a131bbb-1be2-41f7-8e3d-97a8bd2325fe-image.png
                                  Holding Register:
                                  R_Holding_Register.txt

                                2. Modbus Instanz ACTHOR Bezugs-Leistung vorgeben:
                                  Einstellungen:
                                  6cb84315-bd06-4e06-8dd0-f88d48bd2089-image.png
                                  6390ef5d-3952-47fe-8433-cf4c7fd9e1e9-image.png
                                  Holding Register:
                                  W_Holding_Register.txt

                                MyPV ACTHOR9S
                                E/Ethernet Version: a0020900  
                                P/Leistungsteil Version: 110  
                                S/Leistungsteil 9s Version: 102

                                Einstellungen am ACTHOR:
                                6bbbea87-7744-4b34-a599-8f3a9f5a596c-image.png
                                4d2fd408-abec-4e17-b12e-c7e2a483f750-image.png

                                1 Reply Last reply Reply Quote 0
                                • P
                                  PEPITO82 @wendy2702 last edited by

                                  @wendy2702 Vielen Dank fürs Teilen. Hast Du es mittlerweile vielleicht auch noch hinbekommen, dass man beim Setzen der Solltemperatur den tatsächlichen Temperaturwert angibt statt mit einer zusätzlichen 0?

                                  Ich nutze auch noch diese Register:
                                  5030 --> Heizen Handabschaltung
                                  5032 --> Warmwasser Handabschaltung
                                  6270 --> Schalter Heizungspumpe

                                  Ggf. sind die für Dich auch noch interessant.

                                  M wendy2702 2 Replies Last reply Reply Quote 0
                                  • M
                                    mane444 @PEPITO82 last edited by

                                    @pepito82 Ich kenn das so nicht.
                                    Ich gebe im Register 1002 die Temperatur vor, und die kommt so auch beim ACTHOR an.
                                    35a01e72-e89b-47c8-9cbd-cc709f85d091-image.png 90a4864d-68d5-475a-b4f9-d8dfdd0589b1-image.png
                                    Hast du den Faktor richtig gesetzt ?
                                    6b576a00-d36a-40f3-864c-a27cf7c1a5ff-image.png

                                    P 1 Reply Last reply Reply Quote 1
                                    • P
                                      PEPITO82 @mane444 last edited by

                                      @mane444 Danke. Ich hatte mit einer Formel gearbeitet. Mit Faktor funktioniert es einwandfrei.

                                      1 Reply Last reply Reply Quote 0
                                      • wendy2702
                                        wendy2702 @PEPITO82 last edited by

                                        @pepito82 sagte in Aufruf Sammlung an Modbus Anbindungen:

                                        @wendy2702 Vielen Dank fürs Teilen. Hast Du es mittlerweile vielleicht auch noch hinbekommen, dass man beim Setzen der Solltemperatur den tatsächlichen Temperaturwert angibt statt mit einer zusätzlichen 0?

                                        Ich nutze auch noch diese Register:
                                        5030 --> Heizen Handabschaltung
                                        5032 --> Warmwasser Handabschaltung
                                        6270 --> Schalter Heizungspumpe

                                        Ggf. sind die für Dich auch noch interessant.

                                        Wegen der zusätzlichen "0" wurde ja gelöst, wobei mir das persönlich egal ist ob das Script 55 oder 550 schreibt.

                                        Kannst du den Export der anderen Register bereitstellen?

                                        1 Reply Last reply Reply Quote 0
                                        • A
                                          andi2055 last edited by andi2055

                                          Anbei meine Config für:

                                          SMA Sunny Tripower X

                                          Dieser hat jedoch eine fehlerhafte und unvollständige Implementierung der Modbus-Schnittstelle (Firmware 02.06.06.R).
                                          Einige wichtige Werte fehlen komplett: z.B. erzeugte Gesamtenergie
                                          Andere sind einfach falsch: bestimmte Werte werden für alle 3 MPP identisch angezeigt, obwohl unterschiedlich.
                                          Um trotzdem alle Werte korrekt auslesen zu können, kombiniere ich die Modbus-Werte mit SMAHub (siehe hier: https://forum.iobroker.net/post/1016893)
                                          Aus diesem Grund nutze ich nur folgende: 30775, 30777, 30779, 30781, 30795
                                          Folgend einige weitere - in der Hoffnung, das SMA hier nachbessert.
                                          Ich habe bei SMA ein Ticket eröffnet und die Probleme geschildert. Macht das bitte auch!

                                          _address	name	description	unit	type	len	factor	offset	formula	role	room	cw	isScale
                                          30775	Measurement.GridMs.TotW	Leistung	W	int32be	2	1	0	x<0?0:x	level		false	false
                                          30777	Measurement.GridMs.W.phsA	Leistung L1	W	int32be	2	1		x<0?0:x	level		false	false
                                          30779	Measurement.GridMs.W.phsB	Leistung L2	W	int32be	2	1		x<0?0:x	level		false	false
                                          30781	Measurement.GridMs.W.phsC	Leistung L2	W	int32be	2	1		x<0?0:x	level		false	false
                                          30783	Measurement.GridMs.PhV.phsA	Netzspannung Phase L1	V	uint32be	2	0,01		x>1000?0:x*0.01	level		false	false
                                          30785	Measurement.GridMs.PhV.phsB	Netzspannung Phase L2	V	uint32be	2	0,01		x>1000?0:x*0.01	level		false	false
                                          30787	Measurement.GridMs.PhV.phsC	Netzspannung Phase L3	V	uint32be	2	0,01		x>1000?0:x*0.01	level		false	false
                                          30789	Measurement.GridMs.PhV.phsA2B	Netzspannung Phase L1 gegen L2	V	uint32be	2	0,01		x>1000?0:x*0.01	level		false	false
                                          30791	Measurement.GridMs.PhV.phsB	Netzspannung Phase L2 gegen L3	V	uint32be	2	0,01		x>1000?0:x*0.01	level		false	false
                                          30793	Measurement.GridMs.PhV.phsC	Netzspannung Phase L3 gegen L1	V	uint32be	2	0,01		x>1000?0:x*0.01	level		false	false
                                          30795	Measurement.GridMs.TotA	Netzstrom	A	uint32be	2	0,001		x>30000?0:x*0.001	level		false	false
                                          30797	Measurement.GridMs.A.phsA	Netzstrom L1	A	uint32be	2	0,001		x>1000?0:x*0.001	level		false	false
                                          30799	Measurement.GridMs.A.phsB	Netzstrom L2	A	uint32be	2	0,001		x>1000?0:x*0.001	level		false	false
                                          30801	Measurement.GridMs.A.phsC	Netzstrom L3	A	uint32be	2	0,001		x>1000?0:x*0.001	level		false	false
                                          30803	Measurement.GridMs.Hz	Netzfrequenz	Hz	uint32be	2	0,01		x>6000?0:x*0.01	level		false	false
                                          30805	Measurement.GridMs.TotVAr	Blindleistung	Var	int32be	2	0,01		x<0?0:x*0.01	level		false	false
                                          30807	Measurement.GridMs.VAr.phsA	Blindleistung L1	Var	int32be	2	0,01		x<0?0:x*0.01	level		false	false
                                          30809	Measurement.GridMs.VAr.phsB	Blindleistung L2	Var	int32be	2	0,01		x<0?0:x*0.01	level		false	false
                                          30811	Measurement.GridMs.VAr.phsC	Blindleistung L3	Var	int32be	2	0,01		x<0?0:x*0.01	level		false	false
                                          30813	Measurement.GridMs.TotVA	Scheinleistung	VA	int32be	2	0,01		x<0?0:x*0.01	level		false	false
                                          30815	Measurement.GridMs.VA.phsA	Scheinleistung L1	VA	int32be	2	0,01		x<0?0:x*0.01	level		false	false
                                          30817	Measurement.GridMs.VA.phsB	Scheinleistung L2	VA	int32be	2	0,01		x<0?0:x*0.01	level		false	false
                                          30819	Measurement.GridMs.VA.phsC	Scheinleistung L3	VA	int32be	2	0,01		x<0?0:x*0.01	level		false	false
                                          30957	Measurement.DcMs.Amp	DC Strom Eingang	A	int32be	2	0,001		x<-1000?0:x*0.001	level		false	false
                                          30959	Measurement.DcMs.Vol	DC Spannung Eingang	V	int32be	2	0,01		x<-1000?0:x*0.01	level		false	false
                                          30961	Measurement.DcMs.Watt	DC Leistung Eingang	W	int32be	2	1		x<-1000?0:x	level		false	false
                                          30963	Measurement.DcMs.Amp	DC Strom Eingang	A	int32be	2	0,001		x<-1000?0:x*0.001	level		false	false
                                          30965	Measurement.DcMs.Vol	DC Spannung Eingang	V	int32be	2	0,01		x<-1000?0:x*0.01	level		false	false
                                          30967	Measurement.DcMs.Watt	DC Leistung Eingang	W	int32be	2	1		x<-1000?0:x	level		false	false
                                          30969	Measurement.DcMs.Amp	DC Strom Eingang	A	int32be	2	0,001		x<-1000?0:x*0.001	level		false	false
                                          30971	Measurement.DcMs.Vol	DC Spannung Eingang	V	int32be	2	0,01		x<-1000?0:x*0.01	level		false	false
                                          30973	Measurement.DcMs.Watt	DC Leistung Eingang	W	int32be	2	1		x<-1000?0:x	level		false	false
                                          30975	Measurement.Inverter.DclVol	Zwischenkreisspannung	V	int32be	2	0,01		x<-1000?0:x*0.01	level		false	false
                                          30977	Measurement.GridMs.A.phsA	Netzstrom Phase L1	A	int32be	2	0,001		x<-1000?0:x*0.001	level		false	false
                                          30979	Measurement.GridMs.A.phsB	Netzstrom Phase L2	A	int32be	2	0,001		x<-1000?0:x*0.001	level		false	false
                                          30981	Measurement.GridMs.A.phsC	Netzstrom Phase L3	A	int32be	2	0,001		x<-1000?0:x*0.001	level		false	false
                                          
                                          1 Reply Last reply Reply Quote 0
                                          • T
                                            TurboSasch @Sascha Roth last edited by

                                            @sascha-roth kann ich das Register irgendwie auch so einfügen, wie Du es hier eingestellt hast? In der Modbus Instanz kann man ja nur jeweils einen von Hand eingeben.

                                            TheBam 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            798
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            geräte modbus sammlung
                                            31
                                            66
                                            13187
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo